Attachment 21 - RFI 70. B13_WALL_TYPE.pdf

PDF 46 KB Posted

Attached to
Y1BG--EHRM Construction Infrastructure Upgrades - 679-20-104 -Tuscaloosa VAMC
Solicitation number
36C77625R0025
Issued by

About this file

This file is a technical architectural drawing specifying a B1_ Wall Type for a construction project, detailing fire-rated and sound-tested wall specifications for a VA Medical Center infrastructure upgrade. The drawing provides comprehensive technical details for a 3 5/8" metal stud wall with a 4 7/8" total wall width, featuring a one-hour fire rating (UL U465) and a Sound Transmission Class (STC) rating of 40.

Key technical specifications include full-height metal studs at 16" on-center, 5/8" gypsum board on both sides, sound attenuation insulation (3 1/2" thick), deflection tracks, acoustic/fire sealant, and specific mounting details for metal tracks to concrete floor decks using 1 1/2" powder-activated fasteners. The drawing includes multiple section views (head parallel to metal deck, head perpendicular to metal deck, and plan section) and notes that impact-resistant gypsum board can be used on one or both sides equivalently, with reference to specific Underwriters Laboratories (UL) design systems and test numbers.

View the file

Other files

File Type Posted
36C77625R0025 0005.pdf PDF
36C77625R0025 0004.pdf PDF
Amendment 0004 - Attachment 27 - 36C77625R0025_1.pdf PDF
Attachment 23 - RFI 223. JSN Fixtures_Toilet.pdf PDF
Attachment 18 - Laydown Area Site Map.pdf PDF
Attachment 22 - RFI 77. Special Inpsections.xlsx XLSX spreadsheet
Attachment 27 - 36C77625R0025_1.pdf PDF
Attachment 19 - Lead Based Paint Report.pdf PDF
Attachment 20 - Asbestos Report.pdf PDF
Attachment 26 - RFIs - Tuscaloosa_FINAL.pdf PDF
Attachment 14 - Updated WD_3.13.2025.pdf PDF
Attachment 24 - RFI 223. Standard Mounting Heights.pdf PDF
36C77625R0025 0003.pdf PDF
Attachment 25 - RFIs 263-265 Partial Electrical.pdf PDF
36C77625R0025 0002.pdf PDF
36C77625R0025 0001.pdf PDF
Amendment 0001 - Att 01 - 679-20-104 Site Visit Sign-In Sheet.pdf PDF
Amendment 0001 - Att 02 - Pre Proposal Conference - Tuscaloosa.pdf PDF
Attachment 8 -EHRM RTA Drawings_Telecommunications General and New Work.pdf PDF
Attachment 2 - EHRM RTA Drawings_Electrical.pdf PDF
36C77625R0025_1.pdf PDF
Attachment 10 - Submittal Register RTA.xlsx XLSX spreadsheet
Attachment 1 - SOW - EHRM Tuscaloosa.pdf PDF
Attachment 14 - WD - AL20240098 - 01.03.2025.pdf PDF
Attachment 5 - EHRM RTA Drawings_Mechanical and Plumbing.pdf PDF
Attachment 6 - EHRM RTA Drawings_Structural and Architecture.pdf PDF
Attachment 12 - Geotechnical Report - EHRM Data Center.pdf PDF
Attachment 16 - Brand Name - Corbin Russwin - Manufacture Document.pdf PDF
Attachment 11 - TVAMC Site Map_PSRDM.pdf PDF
Attachment 17 - Division Cost Breakdown.xlsx XLSX spreadsheet
Attachment 9 - EHRM RTA Specifications.pdf PDF
Attachment 13 - Limitations on Subcontracting - Construction.pdf PDF
Attachment 7 - EHRM RTA Drawings_Telecommunications General and Demolition.pdf PDF
Attachment 4 - EHRM RTA Drawings_General and Civil.pdf PDF
Attachment 15 - Brand Name - EHRM Tuscaloosa.pdf PDF
Attachment 3 - EHRM RTA Drawings_Fire Protection.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RATING

-FIRE- -SOUND-

TEST # STC TEST #

SCALE: 1 1/2"=1'-0"

1 hr UL U465

FIRE RATED - ONE HOUR

WHERE INDICATED ON PLANS

WALL TYPE IDENTIFIERS

B13 3 5/8" METAL STUDS = 4 7/8" WALL

B1_ WALL TYPE

1" DEFLECTION

1" DEFLECTION

FLOOR

PLAN SECTION

HEAD PERPENDICULAR TO MTL DECK

HEAD PARALLEL TO MTL DECK

STUD SIZE &

WALL TYPE

IDENTIFIER -

METAL TRACK ATTACHED TO CONCRETE FLOOR DECK W/

1 1/2" POWDER ACTIVATED FASTENERS @ 24" O.C. - 4"

FROM ENDS - MINIMUM EMBEDMENT: 1 1/4"

ACOUSTIC SEALANT- TYPICAL

(FIRE SEALANT @ FIRE BARRIERS)

CONCRETE FLOOR SLAB

SOUND ATTENUATION INSULATION , THICKNESS PER STC

RATING (3 1/2" IN B13 & B14 AND 6" IN B16)

FULL HEIGHT METAL STUDS @ 16" O.C.

5/8" GYPSUM BOARD, BOTH SIDES

DEFLECTION TRACK PER TESTED UL

DESIGN - FASTEN TO METAL DECK

CONCRETE

INSULATION PER HEAD OF WALL TESTED UL DESIGN

(@ FIRE BARRIERS)

BOTTOM

OF METAL

DECK

DEFLECTION TRACK PER TESTED DESIGN - FASTEN

TO STRAPS PER DESIGN - STRAPS @ 16" O.C.

FIRE SEALANT PER TESTED DESIGN BOTH SIDES

(@FIRE BARRIERS)

CONCRETE

METAL DECK

INSULATION PER TESTED HEAD OF WALL DESIGN

(@ FIRE BARRIERS)

5/8" GYPSUM BOARD BOTH SIDES - TYPICAL

1"

1/ 2"

SEE BELOW

STI SYSTEM No. HW-D-0456

STI SYSTEM No. HW-D-0456

5/8" GYPSUM BOARD BOTH SIDES - TYPICAL

CEILING RUNNER

CEILING RUNNER

& UL V438

NGC 2013004

NGC 25181 hr 40

NOTE: IMPACT RESISTANCE GYPSUM BOARD

ON ONE OR BOTH SIDES ARE EQUIVALENT.

Drafting Views (Detail)
A7_WALL TYPES-MTL STUDS_B1

File details come from the government source that posted it. Updated .