ADDENDUM 03_Dwgs.pdf

PDF 2 MB Posted

Attached to
Y1LZ--762-301 CMOP Building Acquisition Minor Construction - Tucson
Solicitation number
36C77623B0039
Issued by

About this file

This document package includes construction drawings and specifications for a federal contract opportunity to acquire a new building and make site improvements at the Tucson VA CMOP facility. The scope of work involves demolishing existing fences and landscaping, constructing new fencing and gates around the perimeter, installing security equipment such as electric locks and cameras at pedestrian and vehicle access points, and repaving parking areas. The project will provide a secured entry control point and improve traffic flow for deliveries and employees. Future phases outlined in the drawings would expand the fenced area and make additional security upgrades. The solicitation was issued by the VA Technology Acquisition Center for the Y1LZ-762-301 CMOP Building Acquisition Minor Construction contract in Tucson, Arizona.

View the file

Other files

File Type Posted
36C77623B0039 0004.docx DOCX document
32 31 11 Gate Operator.pdf PDF
Technical Questions - FINAL 2 - TUCSON - 06.20.2023.pdf PDF
standard drop arm gate.pdf PDF
ADDENDUM 03 - Front End Doc.pdf PDF
00 01 10 Spec TOC.pdf PDF
36C77623B0039 0003.docx DOCX document
36C77623B0039_Civil Doc 1.pdf PDF
36C77623B0039_Addendum 02.pdf PDF
36C77623B0039_Addendum 02 - Drawings.pdf PDF
Technical Questions - FINAL - Tucson 06-07-2023.pdf PDF
36C77623B0039 0002.docx DOCX document
36C77623B0039_Mech Doc 2.pdf PDF
36C77623B0039_Mech Doc 1.pdf PDF
36C77623B0039_25 10 10 Advanced Utility Metering System.pdf PDF
36C77623B0039_Geo Report.pdf PDF
Site Visit Sign-in Sheet - Tucson 5-11-23.pdf PDF
36C77623B0039 0001.docx DOCX document
ATTACHMENT 2 - Drawings 1of1.pdf PDF
ATTACHMENT 3 - Drawings 2of2.pdf PDF
ATTACHMENT 4 - Geotechnical Report.pdf PDF
ATTACHMENT 8 - SIte Visit Instructions.pdf PDF
ATTACHMENT 7 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 6 - Construction Wage Rates - Pima 2-3-23.pdf PDF
ATTACHMENT 1 - Specifications.pdf PDF
36C77623B0039_1.docx DOCX document
ATTACHMENT 5 - Limitations on Subcontracting - Construction.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E BRITANNIA DR

E H

E M

IS

P

H E

R E

L O

O P

VISITOR PARKING

E DESERT WALK LN

CMOP

38'-6" 25'-0" 20'-6" 173'-6" 52'-0"

'-3

'-0

436'-10" FV

1'

-5

F V

2'

-4

F V

2.07

2.22

2.112.12

2.14

2.23

2.13

2.11

2.11

2.12

2.15

2.12

2.23

2.11

2.16

2.17

2.18

2.102.10

2.22

226'-11" FV

248'-6" FV

2.22

2.07

2.23

LANDSCAPED AREA

PAVED AREA

EXISTING BUILDING

EXTENTS TO BE DEMOLISHED

EXISTING FENCE TO REMAIN

LANDSCAPED AREA TO BE DEMOLISHED

EXISTING FENCE TO BE DEMOLISHED

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

CERTIFICATE OF AUTHORITY NO. 20013-0

EXP. 09/30/2022

CIVIL ENGINEER

H2B, INC.

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:5 :1

P

M

DEMO ARCHITECTURAL SITE PLAN

ECO 17 36DRH

ISSUED FOR CONSTRUCTION

TUCSON CMOP BUILDING

ACQUISITION MINOR

03/14/2022

762-301

VA CMOP

3675 E. BRITANNIA DR.

TUCSON, ARIZONA, 85706

AS001

SPUR #: 2091.02

1" = 50'-0"

DEMO SITE PLAN1

DEMO SITE PLAN LEGEND

N

KEYNOTE LEGEND

2.07 DEMO EXISTING FENCE TO EXTENTS INDICATED

2.10 DEMO EXISTING LANDSCAPE AND PREPARE AREA FOR NEW CURBS AND PAVEMENT

2.11 EXISTING FIRE HYDRANT TO REMAIN

2.12 EXISTING MAN GATE TO REMAIN

2.13 EXISTING LIGHTING PEDESTAL TO REMAIN

2.14 EXISTING STANDPIPE TO REMAIN

2.15 EXISTING HVAC UNITS TO REMAIN

2.16 EXISTING CONEX / HVAC EQUIP. TO REMAIN

2.17 EXISTING UPS TO REMAIN

2.18 EXISTING GENERATOR TO REMAIN

2.22 DEMO EXISTING CHAIN LINK FENCE IN ITS ENTIRETY

2.23 DEMO EXISTING DOUBLE SWING GATE IN ITS ENTIRETY

No. REVISION DESCRIPTION DATE

3 ADDENDUM 03 06/19/2023

E BRITANNIA DR

E H

E M

IS

P

H E

R E

L O

O P

DELIVERY/

LOGISTIC EXIT

E DESERT WALK LN

CMOP

DELIVERY

EXIT

DELIVERY/

LOGISTIC

ENTRY

EMPLOYEE

ENTRY / EXIT

EMPLOYEE

ENTRY / EXIT

ONE WAY EXIT ONLY

ONE

WAY

TRAFFIC

ONE WAY EXIT ONLY

'-4

'-0

130'-6" 17'-0" 39'-0" 38'-0" 128'-2" 4'-0" 9" 19'-4"

130'-6" FV 256'-11"

'-0

F

V

9' -3

F

V

2.0832.152.082.12

32.02 32.03

32.04

32.03 32.02

32.07 32.05

32.03 32.06

32.02 32.08

2.13

2.19

2.082.08

32.02

32.07

2.12

2.15

32.11

2.12

2.16

2.17

2.18 32.1132.1132.11

32.07

2.202.20

26.01

92'-0" 89'-4"

2'-0" 20'-0"

21 21 21 21

81010

910 10

19 22

7'-0" 20'-0"

6"

'-0

1'-6" 32'-0"

'-0

'-0

'-1

'-4

'-4

'-1

0"

0' -6

'-2

'-9

29'-5" 85'-0" 85'-0"

45'-10" 7'-5" 84'-7" 28'-2" 85'-4"

278'-6" FV

5'

-2

F V

428'-6" FV

24'-0" FV 206'-0" FV 29'-0" FV

'-1

0"

'-5

8"8'-8"8'-0"6'-0"8'-0"6'-0"

E4

E4

E4

E4

E4

E2

E1

E2

E1

E1

32.10

32.10

32.10

32.10 32.10

32.10

8"

2.12

E3

E5

E3 E5

E3E5

E3 E5

E3 E5 32.03

2.11

2.11

2.12

2.11

370'-0" FV

3'-6"

'-8

'-8

36'-0"

'-1

0"

63'-6"

2.19

246'-4" 10'-8"

32.02

32.02

32.05

32.14

32.14

32.14

32.14

32.14

32.15 32.09

32.15

32.15

32.15

32.15

EXISTING LANDSCAPED AREA

EXISTING FENCING

PAVED AREA

ANTI-RAM BOLLARDS

EXISTING BUILDING

NEW LANDSCAPED AREA

EXTERIOR SIGNAGE

REF. SIGN TYPES (4/AS002)

E1

EXISTING LIGHT FIXTURE

LIGHT FIXTURE REF. ELECTRICAL

NEW FENCING

1. ARM EACH EXISTING AND FUTURE PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH

COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT

SENSOR WITH ANTI-PROP ALARM, AND FIXED FACIAL ANALYTICS CAMERA, ALL MONITORED BY

THE SCC AND A LOCALIZED STATION WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP

MANAGER). ENSURE THE FACIAL ANALYTICS CAMERAS ARE TIED TO THE VA EMPLOYEE

DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE CREDENTIAL USAGE

OR TAILGATING. REFER ELECTRICAL.

2. INSTALL PEDESTRIAN GATES AT EACH VEHICLE GATE, ENSURING THE PEDESTRIAN GATES

ARE CONSTRUCTED OF THE SAME MATERIAL AS THE FENCE SYSTEM, AND ARMED AS

DETAILED IN ITEM 1 ABOVE. ARM EACH PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH

COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT

SENSOR WITH ANTI-PROP ALARM, ALL MONITORED BY THE SCC AND A LOCALIZED STATION

WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP MANAGER). ADDITIONALLY, ENSURE

A FIXED FACIAL ANALYTICS CAMERA IS INSTALLED AT THE GATE ENTRY, TIED TO THE VA

EMPLOYEE DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE

CREDENTIAL USAGE OR TAILGATING. REFER ELECTRICAL.

3. BOLLARD SPACING IS 4" O.C. TYP.

GENERAL PLAN NOTES

PARKING

ONLY

2' -6

2'-0"

1' -6

1'-0"

VA SIGN: EN-10.06 VA SIGN: EN-10.06

VA SIGN: PL-12.04

2' -6

2'-0"

SIGN TYPE: E1 SIGN TYPE: E2

SIGN TYPE: E4

1"

1/ 4"

1/

2" 3/

4"

1/ 2"

1"

NO FIREARMS

VA SIGN: IN-02.11

2' -6

2'-0"

SIGN TYPE: E3

OR WEAPONS

ALLOWED ON

THIS PROPERTY

18 USC § 930

NOTICE

2" 1"

2" 2"

2"

1/ 2"

1" 6"

1'-2"

SIGN TYPE: E5

VIDEO

SURVEILLANCE

IN USE ON

THESE PREMISES

NOTICE

VIDEO SURVEILLANCE SIGN

R E

F . S

IG

N

E

LE

V A

T

IO

N S

S

IZ

E V

A R

IE

S

H E

IG

H

T V

A R

IE

S

. R E

F . S

IG

N

E

LE

V A

T

IO

N S

2' -6

1'-6"

3.01

5.29

5.30

1' -6

4'

-6

PARKING

ONLY

2' -6

7'

-0

6' -0

9' -6

EN-10.06

(SINGLE POST)

PL-12.04

(SINGLE POST)

NO FIREARMS

OR WEAPONS

ALLOWED ON

THIS PROPERTY

18 USC § 930

NOTICE

5' -6

IN-02.11

(WALL MOUNTED)

VIDEO

SURVEILLANCE

IN USE ON

THESE PREMISES

NOTICE

VIDEO SURVEILLANCE SIGN

(WALL MOUNTED)

5' -6 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

CERTIFICATE OF AUTHORITY NO. 20013-0

EXP. 09/30/2022

CIVIL ENGINEER

H2B, INC.

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:5 :1

P

M

ARCHITECTURAL SITE PLAN

ECO 18 36DRH

ISSUED FOR CONSTRUCTION

TUCSON CMOP BUILDING

ACQUISITION MINOR

03/14/2022

762-301

VA CMOP

3675 E. BRITANNIA DR.

TUCSON, ARIZONA, 85706

AS002

SPUR #: 2091.02

1" = 50'-0"

SITE PLAN1

SITE PLAN LEGEND

N

KEYNOTE LEGEND

5.30 1/8" ALUMINUM PANEL WITH SURFACE APPLIED REFLECTIVE VINYL. REF. SIGN TYPES

26.01 LIGHT FIXTURE, TYP. REF. ELECTRICAL

32.02 NEW FENCE TO MATCH EXISTING

32.03 GATE CONTROL ISLAND

32.04 ANTI-RAM BARRIERS ASTM F2656 M10

32.05 RETRACTABLE ANTI-RAM SYSTEM ASTM F2656 M30

32.06 NEW PEDESTRIAN GATE

32.07 30' SLIDING GATE AND TRACK

32.08 40' SLIDING GATE AND TRACK

32.09 50' SLIDING GATE AND TRACK

32.10 PAVEMENT MARKINGS

32.11 ANTI-RAM BARRIERS ASTM F2656 M30

32.14 GATE OPERATOR. LOCATION TO BE COORDINATED ON FIELD. REF. SPEC FOR

CONCRETE PAD, IF NEEDED.

32.15 PROVIDE SECURE CONNECTION BETWEEN NEW AND EXISTING FENCE AT THIS

LOCATION

KEYNOTE LEGEND

2.08 EXISTING FENCE TO REMAIN

2.11 EXISTING FIRE HYDRANT TO REMAIN

2.12 EXISTING MAN GATE TO REMAIN

2.13 EXISTING LIGHTING PEDESTAL TO REMAIN

2.15 EXISTING HVAC UNITS TO REMAIN

2.16 EXISTING CONEX / HVAC EQUIP. TO REMAIN

2.17 EXISTING UPS TO REMAIN

2.18 EXISTING GENERATOR TO REMAIN

2.19 EXISTING SLIDING GATE TO REMAIN

2.20 EXISTING PARKING AND ISLANDS TO REMAIN

3.01 CONCRETE FOOTING

5.29 3" X 3" STEEL POST

1 1/2" = 1'-0"

SIGN TYPES4

1" = 1'-0"

TYP. SINGLE POST DETAIL21" = 1'-0"

SIGN ELEVATIONS3

No. REVISION DESCRIPTION DATE

1 ADDENDUM 01 05/20/2022

3 ADDENDUM 03 06/19/2023

1. ARM EACH EXISTING AND FUTURE PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH

COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT

SENSOR WITH ANTI-PROP ALARM, AND FIXED FACIAL ANALYTICS CAMERA, ALL MONITORED BY

THE SCC AND A LOCALIZED STATION WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP

MANAGER). ENSURE THE FACIAL ANALYTICS CAMERAS ARE TIED TO THE VA EMPLOYEE

DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE CREDENTIAL USAGE

OR TAILGATING. REFER ELECTRICAL.

2. INSTALL PEDESTRIAN GATES AT EACH VEHICLE GATE, ENSURING THE PEDESTRIAN GATES

ARE CONSTRUCTED OF THE SAME MATERIAL AS THE FENCE SYSTEM, AND ARMED AS

DETAILED IN ITEM 1 ABOVE. ARM EACH PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH

COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT

SENSOR WITH ANTI-PROP ALARM, ALL MONITORED BY THE SCC AND A LOCALIZED STATION

WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP MANAGER). ADDITIONALLY, ENSURE

A FIXED FACIAL ANALYTICS CAMERA IS INSTALLED AT THE GATE ENTRY, TIED TO THE VA

EMPLOYEE DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE

CREDENTIAL USAGE OR TAILGATING. REFER ELECTRICAL.

3. BOLLARD SPACING IS 4" O.C. TYP.

GENERAL PLAN NOTES

EXISTING LANDSCAPED AREA

PAVED AREA

EXISTING BUILDING

NEW LANDSCAPED AREA

FUTURE BUILDING

EXISTING FENCING

NEW FENCING

LIGHT FIXTURE REF. ELECTRICAL

E BRITANNIA DR

E H

E M

IS

P

H E

R E

L O

O P

DELIVERY/

LOGISTIC EXIT

E DESERT WALK LN

CMOP

DELIVERY

EXIT

DELIVERY/

LOGISTIC

ENTRY

EMPLOYEE

ENTRY / EXIT

EMPLOYEE

ENTRY / EXIT

ONE WAY EXIT ONLY

ONE

WAY

TRAFFIC

ONE WAY EXIT ONLY

'-4

'-0

1'

-6

F V

2.08 32.09

2.082.12

32.03 32.02

32.04

32.03 32.02

32.07

32.05

32.03 32.06

32.02

32.08

2.13

32.12

2.08

32.02

32.07

2.12

2.15

32.11

2.12

2.16

2.17

2.18 32.1132.1132.11

32.07

26.04

FUTURE BLDG

STORAGE / ADMIN

DELIVERY

ENTRY

9'

-2

107'-4"

92'-0" 89'-4"

21 21 21 21

81010

910 10

'-0

7'-0" 20'-0" 1'-6" 32'-0"

'-0

'-1

'-1

1"

'-1 0"

'-8

6' -1

0"

'-0

113'-6"68'-5" 99'-7" 7'-5" 84'-7"

5'

-2

F V

85'-0" 85'-0" 85'-0" 57'-7"

357'-0"

'-1

0"

'-0

'-0

3'

-4

9"4'-0"

32.06

32.03 32.13

4'-0" 4'-6"

'-1

0"

32.12

32.13

370'-0" FV

32.13

26.04

26.04

26.04

26.04

26.04

26.04

32.02

32.02

32.05

32.14

32.14

32.14

32.14

32.14

32.14

32.15

32.15

32.15

32.15

32.15

32.15

32.15 32.15 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

CERTIFICATE OF AUTHORITY NO. 20013-0

EXP. 09/30/2022

CIVIL ENGINEER

H2B, INC.

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:5 :1

P

M

FUTURE ARCHITECTURAL SITE PLAN

ECO 19 36DRH

ISSUED FOR CONSTRUCTION

TUCSON CMOP BUILDING

ACQUISITION MINOR

03/14/2022

762-301

VA CMOP

3675 E. BRITANNIA DR.

TUCSON, ARIZONA, 85706

AS003

SPUR #: 2091.02

N

SITE PLAN LEGEND

1" = 50'-0"

FUTURE SITE PLAN1

KEYNOTE LEGEND

2.08 EXISTING FENCE TO REMAIN

2.12 EXISTING MAN GATE TO REMAIN

2.13 EXISTING LIGHTING PEDESTAL TO REMAIN

2.15 EXISTING HVAC UNITS TO REMAIN

2.16 EXISTING CONEX / HVAC EQUIP. TO REMAIN

2.17 EXISTING UPS TO REMAIN

2.18 EXISTING GENERATOR TO REMAIN

26.04 FUTURE LIGHT FIXTURE, TYP. REF. ELECTRICAL. OUT OF SCOPE

32.02 NEW FENCE TO MATCH EXISTING

32.03 GATE CONTROL ISLAND

32.04 ANTI-RAM BARRIERS ASTM F2656 M10

32.05 RETRACTABLE ANTI-RAM SYSTEM ASTM F2656 M30

32.06 NEW PEDESTRIAN GATE

32.07 30' SLIDING GATE AND TRACK

32.08 40' SLIDING GATE AND TRACK

32.09 50' SLIDING GATE AND TRACK

32.11 ANTI-RAM BARRIERS ASTM F2656 M30

32.12 FUTURE SLIDING GATE AND TRACK, OUT OF SCOPE

32.13 FUTURE FENCE TO MATCH EXISTING, OUT OF SCOPE

32.14 GATE OPERATOR. LOCATION TO BE COORDINATED ON FIELD. REF. SPEC FOR CONCRETE

PAD, IF NEEDED.

32.15 PROVIDE SECURE CONNECTION BETWEEN NEW AND EXISTING FENCE AT THIS LOCATION

FOR REFERENCE ONLY

No. REVISION DESCRIPTION DATE

1 ADDENDUM 01 05/20/2022

3 ADDENDUM 03 06/19/2023

Sheets
AS001 - DEMO ARCHITECTURAL SITE PLAN
AS002 - ARCHITECTURAL SITE PLAN
AS003 - FUTURE ARCHITECTURAL SITE PLAN

File details come from the government source that posted it. Updated .