ADDENDUM 03_Dwgs.pdf
PDF 2 MB Posted
- Solicitation number
- 36C77623B0039
About this file
This document package includes construction drawings and specifications for a federal contract opportunity to acquire a new building and make site improvements at the Tucson VA CMOP facility. The scope of work involves demolishing existing fences and landscaping, constructing new fencing and gates around the perimeter, installing security equipment such as electric locks and cameras at pedestrian and vehicle access points, and repaving parking areas. The project will provide a secured entry control point and improve traffic flow for deliveries and employees. Future phases outlined in the drawings would expand the fenced area and make additional security upgrades. The solicitation was issued by the VA Technology Acquisition Center for the Y1LZ-762-301 CMOP Building Acquisition Minor Construction contract in Tucson, Arizona.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E BRITANNIA DR
E H
E M
IS
P
H E
R E
L O
O P
VISITOR PARKING
E DESERT WALK LN
CMOP
38'-6" 25'-0" 20'-6" 173'-6" 52'-0"
'-3
'-0
436'-10" FV
1'
-5
F V
2'
-4
F V
2.07
2.22
2.112.12
2.14
2.23
2.13
2.11
2.11
2.12
2.15
2.12
2.23
2.11
2.16
2.17
2.18
2.102.10
2.22
226'-11" FV
248'-6" FV
2.22
2.07
2.23
LANDSCAPED AREA
PAVED AREA
EXISTING BUILDING
EXTENTS TO BE DEMOLISHED
EXISTING FENCE TO REMAIN
LANDSCAPED AREA TO BE DEMOLISHED
EXISTING FENCE TO BE DEMOLISHED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
CERTIFICATE OF AUTHORITY NO. 20013-0
EXP. 09/30/2022
CIVIL ENGINEER
H2B, INC.
1225 NORTH LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:5 :1
P
M
DEMO ARCHITECTURAL SITE PLAN
ECO 17 36DRH
ISSUED FOR CONSTRUCTION
TUCSON CMOP BUILDING
ACQUISITION MINOR
03/14/2022
762-301
VA CMOP
3675 E. BRITANNIA DR.
TUCSON, ARIZONA, 85706
AS001
SPUR #: 2091.02
1" = 50'-0"
DEMO SITE PLAN1
DEMO SITE PLAN LEGEND
N
KEYNOTE LEGEND
2.07 DEMO EXISTING FENCE TO EXTENTS INDICATED
2.10 DEMO EXISTING LANDSCAPE AND PREPARE AREA FOR NEW CURBS AND PAVEMENT
2.11 EXISTING FIRE HYDRANT TO REMAIN
2.12 EXISTING MAN GATE TO REMAIN
2.13 EXISTING LIGHTING PEDESTAL TO REMAIN
2.14 EXISTING STANDPIPE TO REMAIN
2.15 EXISTING HVAC UNITS TO REMAIN
2.16 EXISTING CONEX / HVAC EQUIP. TO REMAIN
2.17 EXISTING UPS TO REMAIN
2.18 EXISTING GENERATOR TO REMAIN
2.22 DEMO EXISTING CHAIN LINK FENCE IN ITS ENTIRETY
2.23 DEMO EXISTING DOUBLE SWING GATE IN ITS ENTIRETY
No. REVISION DESCRIPTION DATE
3 ADDENDUM 03 06/19/2023
E BRITANNIA DR
E H
E M
IS
P
H E
R E
L O
O P
DELIVERY/
LOGISTIC EXIT
E DESERT WALK LN
CMOP
DELIVERY
EXIT
DELIVERY/
LOGISTIC
ENTRY
EMPLOYEE
ENTRY / EXIT
EMPLOYEE
ENTRY / EXIT
ONE WAY EXIT ONLY
ONE
WAY
TRAFFIC
ONE WAY EXIT ONLY
'-4
'-0
130'-6" 17'-0" 39'-0" 38'-0" 128'-2" 4'-0" 9" 19'-4"
130'-6" FV 256'-11"
'-0
F
V
9' -3
F
V
2.0832.152.082.12
32.02 32.03
32.04
32.03 32.02
32.07 32.05
32.03 32.06
32.02 32.08
2.13
2.19
2.082.08
32.02
32.07
2.12
2.15
32.11
2.12
2.16
2.17
2.18 32.1132.1132.11
32.07
2.202.20
26.01
92'-0" 89'-4"
2'-0" 20'-0"
21 21 21 21
81010
910 10
19 22
7'-0" 20'-0"
6"
'-0
1'-6" 32'-0"
'-0
'-0
'-1
'-4
'-4
'-1
0"
0' -6
'-2
'-9
29'-5" 85'-0" 85'-0"
45'-10" 7'-5" 84'-7" 28'-2" 85'-4"
278'-6" FV
5'
-2
F V
428'-6" FV
24'-0" FV 206'-0" FV 29'-0" FV
'-1
0"
'-5
8"8'-8"8'-0"6'-0"8'-0"6'-0"
E4
E4
E4
E4
E4
E2
E1
E2
E1
E1
32.10
32.10
32.10
32.10 32.10
32.10
8"
2.12
E3
E5
E3 E5
E3E5
E3 E5
E3 E5 32.03
2.11
2.11
2.12
2.11
370'-0" FV
3'-6"
'-8
'-8
36'-0"
'-1
0"
63'-6"
2.19
246'-4" 10'-8"
32.02
32.02
32.05
32.14
32.14
32.14
32.14
32.14
32.15 32.09
32.15
32.15
32.15
32.15
EXISTING LANDSCAPED AREA
EXISTING FENCING
PAVED AREA
ANTI-RAM BOLLARDS
EXISTING BUILDING
NEW LANDSCAPED AREA
EXTERIOR SIGNAGE
REF. SIGN TYPES (4/AS002)
E1
EXISTING LIGHT FIXTURE
LIGHT FIXTURE REF. ELECTRICAL
NEW FENCING
1. ARM EACH EXISTING AND FUTURE PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH
COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT
SENSOR WITH ANTI-PROP ALARM, AND FIXED FACIAL ANALYTICS CAMERA, ALL MONITORED BY
THE SCC AND A LOCALIZED STATION WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP
MANAGER). ENSURE THE FACIAL ANALYTICS CAMERAS ARE TIED TO THE VA EMPLOYEE
DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE CREDENTIAL USAGE
OR TAILGATING. REFER ELECTRICAL.
2. INSTALL PEDESTRIAN GATES AT EACH VEHICLE GATE, ENSURING THE PEDESTRIAN GATES
ARE CONSTRUCTED OF THE SAME MATERIAL AS THE FENCE SYSTEM, AND ARMED AS
DETAILED IN ITEM 1 ABOVE. ARM EACH PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH
COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT
SENSOR WITH ANTI-PROP ALARM, ALL MONITORED BY THE SCC AND A LOCALIZED STATION
WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP MANAGER). ADDITIONALLY, ENSURE
A FIXED FACIAL ANALYTICS CAMERA IS INSTALLED AT THE GATE ENTRY, TIED TO THE VA
EMPLOYEE DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE
CREDENTIAL USAGE OR TAILGATING. REFER ELECTRICAL.
3. BOLLARD SPACING IS 4" O.C. TYP.
GENERAL PLAN NOTES
PARKING
ONLY
2' -6
2'-0"
1' -6
1'-0"
VA SIGN: EN-10.06 VA SIGN: EN-10.06
VA SIGN: PL-12.04
2' -6
2'-0"
SIGN TYPE: E1 SIGN TYPE: E2
SIGN TYPE: E4
1"
1/ 4"
1/
2" 3/
4"
1/ 2"
1"
NO FIREARMS
VA SIGN: IN-02.11
2' -6
2'-0"
SIGN TYPE: E3
OR WEAPONS
ALLOWED ON
THIS PROPERTY
18 USC § 930
NOTICE
2" 1"
2" 2"
2"
1/ 2"
1" 6"
1'-2"
SIGN TYPE: E5
VIDEO
SURVEILLANCE
IN USE ON
THESE PREMISES
NOTICE
VIDEO SURVEILLANCE SIGN
R E
F . S
IG
N
E
LE
V A
T
IO
N S
S
IZ
E V
A R
IE
S
H E
IG
H
T V
A R
IE
S
. R E
F . S
IG
N
E
LE
V A
T
IO
N S
2' -6
1'-6"
3.01
5.29
5.30
1' -6
4'
-6
PARKING
ONLY
2' -6
7'
-0
6' -0
9' -6
EN-10.06
(SINGLE POST)
PL-12.04
(SINGLE POST)
NO FIREARMS
OR WEAPONS
ALLOWED ON
THIS PROPERTY
18 USC § 930
NOTICE
5' -6
IN-02.11
(WALL MOUNTED)
VIDEO
SURVEILLANCE
IN USE ON
THESE PREMISES
NOTICE
VIDEO SURVEILLANCE SIGN
(WALL MOUNTED)
5' -6 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
CERTIFICATE OF AUTHORITY NO. 20013-0
EXP. 09/30/2022
CIVIL ENGINEER
H2B, INC.
1225 NORTH LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:5 :1
P
M
ARCHITECTURAL SITE PLAN
ECO 18 36DRH
ISSUED FOR CONSTRUCTION
TUCSON CMOP BUILDING
ACQUISITION MINOR
03/14/2022
762-301
VA CMOP
3675 E. BRITANNIA DR.
TUCSON, ARIZONA, 85706
AS002
SPUR #: 2091.02
1" = 50'-0"
SITE PLAN1
SITE PLAN LEGEND
N
KEYNOTE LEGEND
5.30 1/8" ALUMINUM PANEL WITH SURFACE APPLIED REFLECTIVE VINYL. REF. SIGN TYPES
26.01 LIGHT FIXTURE, TYP. REF. ELECTRICAL
32.02 NEW FENCE TO MATCH EXISTING
32.03 GATE CONTROL ISLAND
32.04 ANTI-RAM BARRIERS ASTM F2656 M10
32.05 RETRACTABLE ANTI-RAM SYSTEM ASTM F2656 M30
32.06 NEW PEDESTRIAN GATE
32.07 30' SLIDING GATE AND TRACK
32.08 40' SLIDING GATE AND TRACK
32.09 50' SLIDING GATE AND TRACK
32.10 PAVEMENT MARKINGS
32.11 ANTI-RAM BARRIERS ASTM F2656 M30
32.14 GATE OPERATOR. LOCATION TO BE COORDINATED ON FIELD. REF. SPEC FOR
CONCRETE PAD, IF NEEDED.
32.15 PROVIDE SECURE CONNECTION BETWEEN NEW AND EXISTING FENCE AT THIS
LOCATION
KEYNOTE LEGEND
2.08 EXISTING FENCE TO REMAIN
2.11 EXISTING FIRE HYDRANT TO REMAIN
2.12 EXISTING MAN GATE TO REMAIN
2.13 EXISTING LIGHTING PEDESTAL TO REMAIN
2.15 EXISTING HVAC UNITS TO REMAIN
2.16 EXISTING CONEX / HVAC EQUIP. TO REMAIN
2.17 EXISTING UPS TO REMAIN
2.18 EXISTING GENERATOR TO REMAIN
2.19 EXISTING SLIDING GATE TO REMAIN
2.20 EXISTING PARKING AND ISLANDS TO REMAIN
3.01 CONCRETE FOOTING
5.29 3" X 3" STEEL POST
1 1/2" = 1'-0"
SIGN TYPES4
1" = 1'-0"
TYP. SINGLE POST DETAIL21" = 1'-0"
SIGN ELEVATIONS3
No. REVISION DESCRIPTION DATE
1 ADDENDUM 01 05/20/2022
3 ADDENDUM 03 06/19/2023
1. ARM EACH EXISTING AND FUTURE PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH
COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT
SENSOR WITH ANTI-PROP ALARM, AND FIXED FACIAL ANALYTICS CAMERA, ALL MONITORED BY
THE SCC AND A LOCALIZED STATION WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP
MANAGER). ENSURE THE FACIAL ANALYTICS CAMERAS ARE TIED TO THE VA EMPLOYEE
DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE CREDENTIAL USAGE
OR TAILGATING. REFER ELECTRICAL.
2. INSTALL PEDESTRIAN GATES AT EACH VEHICLE GATE, ENSURING THE PEDESTRIAN GATES
ARE CONSTRUCTED OF THE SAME MATERIAL AS THE FENCE SYSTEM, AND ARMED AS
DETAILED IN ITEM 1 ABOVE. ARM EACH PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH
COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT
SENSOR WITH ANTI-PROP ALARM, ALL MONITORED BY THE SCC AND A LOCALIZED STATION
WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP MANAGER). ADDITIONALLY, ENSURE
A FIXED FACIAL ANALYTICS CAMERA IS INSTALLED AT THE GATE ENTRY, TIED TO THE VA
EMPLOYEE DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE
CREDENTIAL USAGE OR TAILGATING. REFER ELECTRICAL.
3. BOLLARD SPACING IS 4" O.C. TYP.
GENERAL PLAN NOTES
EXISTING LANDSCAPED AREA
PAVED AREA
EXISTING BUILDING
NEW LANDSCAPED AREA
FUTURE BUILDING
EXISTING FENCING
NEW FENCING
LIGHT FIXTURE REF. ELECTRICAL
E BRITANNIA DR
E H
E M
IS
P
H E
R E
L O
O P
DELIVERY/
LOGISTIC EXIT
E DESERT WALK LN
CMOP
DELIVERY
EXIT
DELIVERY/
LOGISTIC
ENTRY
EMPLOYEE
ENTRY / EXIT
EMPLOYEE
ENTRY / EXIT
ONE WAY EXIT ONLY
ONE
WAY
TRAFFIC
ONE WAY EXIT ONLY
'-4
'-0
1'
-6
F V
2.08 32.09
2.082.12
32.03 32.02
32.04
32.03 32.02
32.07
32.05
32.03 32.06
32.02
32.08
2.13
32.12
2.08
32.02
32.07
2.12
2.15
32.11
2.12
2.16
2.17
2.18 32.1132.1132.11
32.07
26.04
FUTURE BLDG
STORAGE / ADMIN
DELIVERY
ENTRY
9'
-2
107'-4"
92'-0" 89'-4"
21 21 21 21
81010
910 10
'-0
7'-0" 20'-0" 1'-6" 32'-0"
'-0
'-1
'-1
1"
'-1 0"
'-8
6' -1
0"
'-0
113'-6"68'-5" 99'-7" 7'-5" 84'-7"
5'
-2
F V
85'-0" 85'-0" 85'-0" 57'-7"
357'-0"
'-1
0"
'-0
'-0
3'
-4
9"4'-0"
32.06
32.03 32.13
4'-0" 4'-6"
'-1
0"
32.12
32.13
370'-0" FV
32.13
26.04
26.04
26.04
26.04
26.04
26.04
32.02
32.02
32.05
32.14
32.14
32.14
32.14
32.14
32.14
32.15
32.15
32.15
32.15
32.15
32.15
32.15 32.15 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
CERTIFICATE OF AUTHORITY NO. 20013-0
EXP. 09/30/2022
CIVIL ENGINEER
H2B, INC.
1225 NORTH LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:5 :1
P
M
FUTURE ARCHITECTURAL SITE PLAN
ECO 19 36DRH
ISSUED FOR CONSTRUCTION
TUCSON CMOP BUILDING
ACQUISITION MINOR
03/14/2022
762-301
VA CMOP
3675 E. BRITANNIA DR.
TUCSON, ARIZONA, 85706
AS003
SPUR #: 2091.02
N
SITE PLAN LEGEND
1" = 50'-0"
FUTURE SITE PLAN1
KEYNOTE LEGEND
2.08 EXISTING FENCE TO REMAIN
2.12 EXISTING MAN GATE TO REMAIN
2.13 EXISTING LIGHTING PEDESTAL TO REMAIN
2.15 EXISTING HVAC UNITS TO REMAIN
2.16 EXISTING CONEX / HVAC EQUIP. TO REMAIN
2.17 EXISTING UPS TO REMAIN
2.18 EXISTING GENERATOR TO REMAIN
26.04 FUTURE LIGHT FIXTURE, TYP. REF. ELECTRICAL. OUT OF SCOPE
32.02 NEW FENCE TO MATCH EXISTING
32.03 GATE CONTROL ISLAND
32.04 ANTI-RAM BARRIERS ASTM F2656 M10
32.05 RETRACTABLE ANTI-RAM SYSTEM ASTM F2656 M30
32.06 NEW PEDESTRIAN GATE
32.07 30' SLIDING GATE AND TRACK
32.08 40' SLIDING GATE AND TRACK
32.09 50' SLIDING GATE AND TRACK
32.11 ANTI-RAM BARRIERS ASTM F2656 M30
32.12 FUTURE SLIDING GATE AND TRACK, OUT OF SCOPE
32.13 FUTURE FENCE TO MATCH EXISTING, OUT OF SCOPE
32.14 GATE OPERATOR. LOCATION TO BE COORDINATED ON FIELD. REF. SPEC FOR CONCRETE
PAD, IF NEEDED.
32.15 PROVIDE SECURE CONNECTION BETWEEN NEW AND EXISTING FENCE AT THIS LOCATION
FOR REFERENCE ONLY
No. REVISION DESCRIPTION DATE
1 ADDENDUM 01 05/20/2022
3 ADDENDUM 03 06/19/2023
| Sheets |
| AS001 - DEMO ARCHITECTURAL SITE PLAN |
| AS002 - ARCHITECTURAL SITE PLAN |
| AS003 - FUTURE ARCHITECTURAL SITE PLAN |
File details come from the government source that posted it. Updated .