This addendum modifies construction drawings and specifications for the Tucson CMOP Building Acquisition Minor project. Key changes include adding specification section 25 10 10 for an advanced utility metering system, revising grading, erosion control, and fence details, and showing power for electric strikes at five pedestrian gates. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs Technology Acquisition Center Austin for construction of a parking lot at the Tucson CMOP facility under solicitation number 36C77623B0039. Responses are due by the date listed on the solicitation. The scope includes minor construction work to acquire the building.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM 02
PROJECT NUMBER 762-301 (2091.02)
PROJECT NAME Tucson CMOP Building
Acquisition Minor
ADDENDUM NUMBER 02
DATE June 6, 2023 SUBJECT Pre-Bid RFIs
A | 312 SW 25th St. Oklahoma City, OK 73109 P | 405.842.6100 E | howdy@spur-design.com W | spur-design.com
THE FOLLOWING MODIFICATIONS, ADDITIONS, AND DELETIONS ARE HEREBY MADE A PART OF THE CONTRACT DOCUMENTS.
SEAL:
PROJECT MANUAL:
DIVISION 25
1. 25 10 10 - Advanced Utility Metering System
Item 1: Spec section added per contractor’s request.
CONSTRUCTION DRAWINGS:
CIVIL
1. CS-103 – GRADING PLAN – 30 x 42
Item 1: Revised statement in our notes for how to restore disturbed areas
Item 2: Spur # corrected.
2. CS-104 – SECTIONS – 30 x 42
3. CS-106 – SWPPP PLAN – 30 x 42
A | 312 SW 25th St. Oklahoma City, OK 73109 P | 405.842.6100 E | howdy@spur-design.com W | spur-design.com
4. CS-204 – FENCE DETAILS – 30 x 42
Item 1: Removed mow strip from fence detail
5. CS-206 – MISCELLANEOUS DETAILS – 30 x 42
Item 1: Provided 6“ concrete paving detail
Item 2: Provided asphalt patch deails
Item 3: Spur # corrected.
ELECTRICAL
6. ES-101 – ELECTRICAL POWER SITE PLAN – 30 x 42
Item 1: Power shown for electric strikes at five (5) pedestrian gates.
7. ES-601 – ELECTRICAL PANEL SCHEDULES AND DIAGRAMS – 30 x 42
Item 1: LTP1-11 added for Pedestrian Gate electrical strikes.
TOTAL: 7 Pages [30 x 42]
END OF ADDENDUM NO. 02