36C26319B0007-003.pdf
PDF 2 MB Posted
- Attached to
- PN: 568-18-102, Upgrade NFS HVAC System (FM)
- Solicitation number
- 36C26319B0007
About this file
36C26319B0007 S02_Drawings (6 pages) 02.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26319C0199-000.docx | DOCX document | |
| 36C26319B0007-0008009.docx | DOCX document | |
| 36C26319B0007-0008008.docx | DOCX document | |
| 36C26319B0007-0007001.pdf | ||
| 36C26319B0007-0007000.docx | DOCX document | |
| 36C26319B0007-0006000.docx | DOCX document | |
| 36C26319B0007-0006001.docx | DOCX document | |
| 36C26319B0007-0005000.docx | DOCX document | |
| 36C26319B0007-0004000.docx | DOCX document | |
| 36C26319B0007-0004001.docx | DOCX document | |
| 36C26319B0007-0003000.docx | DOCX document | |
| 36C26319B0007-0002002.pdf | ||
| 36C26319B0007-0002001.docx | DOCX document | |
| 36C26319B0007-0002000.docx | DOCX document | |
| 36C26319B0007-0001001.docx | DOCX document | |
| 36C26319B0007-0001000.docx | DOCX document | |
| 36C26319B0007-004.docx | DOCX document | |
| 36C26319B0007-002.pdf | ||
| 36C26319B0007-001.docx | DOCX document | |
| 36C26319B0007-000.docx | DOCX document | |
| 36C26319B0007-000.docx | DOCX document |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
U
S
T
E
R
A
V
E
N
U
E
T
E
R
Y
O
A
D
S
T
U
R
G
I
S
A
D
T
R
E
E
T
N
D
R
E
E
T
R
D
S
T
R
E
E
T
C
E
M
E
T
A
D
I
V
E
CUSTER AVENUE
C
I
R
C
L
E
M
A
C
K
E
N
Z
I
TER
RY
R
O
A
D
T
E
R
A
D
S
H
E
R
ID
A
R
E
E
T
R
E
A
D
H
R
E
E
T
C
O
M
A
N
C
H
A
D
T
H
S
T
R
E
E
T
72e
72w
T296
11 360
T-274
BLEACHERS
BLEACHERS
4/19/2019 MS MR
G-001
COVER SHEET
AREA OF WORKVICINITY MAP SHEET INDEX
UPGRADE NFS HVAC SYSTEM
FT. MEADE, SD
VAMC PROJECT #: 568-18-102
BUILDING 146
ADDENDUM #1, NOTE #2 pg. M-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
04/22/2019 CONSULTANTS: ARCHITECT/ENGINEERS: STAMP:
VEG 18.15
568-18-102
VA MEDICAL CENTER - FT. MEADE, SD
UPGRADE NFS HVAC SYSTEM
FORT MEADE, SD
100% CONSTRUCTION
DOCUMENTS
BUILDING 146
SCALE 1/32" = 1'-0"
N o r t h
N o r t h
AREA OF WORK
CRANE STAGING AREA
HVAC GENERAL NOTES
MECHANICAL ABBREVIATIONS
SR SUPPLY AIR REGISTER
SS STAINLESS STEEL
SSHX STEAM TO STEAM HEAT EXCHANGER
SSR SOLID SEPARATOR
ST STEAM TRAP
SUH STEAM UNIT HEATER
SV STEAM PRESSURE REDUCING VALVE
SVS STEAM VENT SILENCER
SWHX STEAM TO WATER HEAT EXCHANGER
T&PCV TEMPERATURE AND PRESSURE CONTROL VALVE
TAB TESTING, ADJUSTING, AND BALANCING
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TG TRANSFER GRILLE
TP TRAP
TR TOP REGISTER
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TWU THRU-WALL UNIT
UCT UNDERCUT
UC UNIT COOLER
UH UNIT HEATER
UL UNDERWRITER'S LABORATORY
URV UPBLAST UNIT VENTILATOR
V VALVE
VAF VANE-AXIAL FAN
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
VHA VETERANS HEALTH ADMINISTRATION
VI VIBRATION ISOLATOR
VIV VARIABLE INLET VANES
VP VACUUM PUMP
VPS VARIABLE PRIMARY SYSTEM
VR VACUUM (STEAM CONDENSATE) RETURN
VSD VARIABLE SPEED DRIVE
VUH VERTICAL UNIT HEATER
W WASTE
WAG WASTE ANESTHESIA GAS
WB WET BULB
WC WATER COOLED
WCCH WATER COOLED CHILLER
WCCU WATER COOLED CONDENSING UNIT
WCPU WATER COOLED HEAT PUMPS
WEF WATER COOLED PACKAGED UNIT
WF WATER FILTER
WFCV WATER FLOW CONTROL VALVE
WFM WATER FLOWMETER
WFMD WATER FLOW MEASURING DEVICE
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
YR YEAR
OFM OIL FLOWMETER
OR OPERATING ROOM
P PUMP
PA PASCAL
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT
PD PRESSURE DROP
PEF PROPELLER TYPE EXHAUST FAN
PF PRE-FILTER
PG PRESSURE GAUGE
PGW PROPYLENE GLYCOL-WATER SOLUTION
PHC PREHEAT COIL
PPM PARTS PER MILLION
PRS PRESSURE REGULATING VALVE STATION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH, ABSOLUTE
PSIG POUNDS PER SQUARE INCH, GAGE
PSS PRIMARY SECONDARY SYSTEM
PSV PRESSURE SAFETY VALVE
PTAC PACKAGED TERMINAL AIR CONDITIONER
R/E RETURN OR EXHAUST
RA RETURN AIR
RAD REFRIGERANT AIR DRYER
RAF RADIO FREQUENCY
RAHX ROTARY AIR HEAT EXCHANGER
RAT RETURN AIR TEMPERATURE
RCCH REMOTE CONDENSER CHILLER
RCU RECIPROCATING CHILLER UNIT
RD REFRIGERANT DISCHARGE
RDS ROOM DATA SHEETS
REA RELIEF AIR
RF RETURN FAN
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER
RS REFRIGERANT SUCTION
RTU ROOFTOP UNIT
RV RELIEF VALVE
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SC SHADING COEFFICIENT
SCFM SPINAL CODE INJURY
SCR SILICON CONTROLLED RECTIFIER
SD SMOKE DETECTOR
SD SUPPLY AIR DIFFUSER
SD-1 SCHEMATIC DESIGN SUBMISSION 1
SD-2 SCHEMATIC DESIGN SUBMISSION 2
SDPR SMOKE DAMPER
SDR SMOKE DAMPER (RETURN)
SDS SMOKE DAMPER (SUPPLY)
SEN SENSIBLE HEAT
SF SUPPLY FAN
SG SUPPLY AIR GRILLE
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPD SUPPLY PROCESS AND DISTRIBUTION
SPRV STEAM PRESSURE REDUCING VALVE
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT
IRH INFRARED HEATER
IS INSECT SCREEN
IU INDUCTION UNIT
IV INLET VANES
KG KILOGRAM
KG/H KILOGRAMS PER HOUR
KPA KILOPASCAL
KW KILOWATT
KWH KILOWATT HOURS
L LITER
L/H LITERS PER HOUR
L/M LITERS PER MINUTE
L/S LITERS PER SECOND
LAT LEAVING AIR TEMPERATURE
LB/H POUND PER HOUR
LF LINEAR FOOT (FEET)
LGT LEAVING GLYCOL TEMPERATURE
LH LATENT HEAT
LLHX LIQUID TO LIQUID HEAT EXCHANGER
LPG LIQUID PROPANE GAS
LPR LOW PRESSURE RETURN (STEAM
CONDENSATE)
LPRC LOW PRESSURE STEAM RETURN (CLEAN)
LPS LOW PRESSURE STEAM
LPSC LOW PRESSURE STEAM (CLEAN)
LSD LINEAR SLOT DIFFUSER
LTCP LOCAL TEMPERATURE CONTROL PANEL
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M METER
M/S METERS PER SECOND
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING VALUE
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOV MOTOR OPERATED VALVE
MPR MEDIUM PRESSURE RETURN (STEAM
CONDENSATE)
MPS MEDIUM PRESSURE STEAM
MRI MAGNETIC RESONANCE IMAGING UNIT
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
MZ MULTI-ZONE
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NG NATURAL GAS
NGFM NATURAL GAS FLOW METER
NO NORMALLY OPEN
NOAA NATIONAL OCEANIC & ATMOSPHERIC
ADMINISTRATION
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OAG OUTSIDE AIR GRILLE
OAI OUTSIDE AIR INTAKE
OD OUTER DIAMETER
FF FINAL FILTER
FHX FLUE GAS/FEEDWATER HEAT EXCHANGER
FM FLOW METER
FOHX FUEL OIL HEAT EXCHANGER
FOP FUEL OIL PUMP
FOT FUEL OIL TANK
FPM FEET PER MINUTE
FPS FEET PER SECOND
FPTU FAN POWERED TERMINAL UNIT
FR FLOOR REGISTER
FRP FIBER REINFORCED POLYESTER
FS FLOW SWITCH
FSTAT FREEZESTAT
FT FEET
FT-LB FOOT-POUND
FTR FINNED TUBE RADIATION
FV FACE VELOCITY
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
H HUMIDIFIER
H&CW HOT & COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HD HOOD
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE RETURN (STEAM
CONDENSATE)
HPS HIGH PRESSURE SUPPLY (STEAM)
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING) PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HTM HUMIDIFIER TERMINAL
HUM HUMIDIFIER UNIT MOUNTED
HVD HOISTWAY VENT DAMPER
HVU HEATING AND VENTILATING UNIT
HW HOT WATER
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HEATING WATER PUMP
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
HWUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
HZ HERTZ
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ICF IN-LINE CENTRIFUGAL FAN
ICU INTENSIVE CARE UNIT
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCHES OF WATER COLUMN
IN WG INCHES OF WATER, GAUGE
IN-LB INCH-POUND
IPLV INTEGRATED PART LOAD VALUE
CP CONDENSATE PUMP
CR CEILING REGISTER
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWCC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN (TO COOLING
TOWER)
CWS CONDENSER WATER SUPPLY (FROM COOLING
TOWER)
D DAMPER - AUTOMATIC
D-1 OUTDOOR AIR DAMPER
D-2 RETURN AIR DAMPER
D-3 RELIEF AIR DAMPER
Db DRY BULB TEMPERATURE dB DECIBEL
DD-1 DESIGN DEVELOPMENT SUBMISSION 1
DD-2 DESIGN DEVELOPMENT SUBMISSION 2
DDC DIRECT DIGITAL CONTROLS
DEG DEGREES
DF DIFFUSER
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DP DIFFUSER PLATE
DPA DIFFERENTIAL PRESSURE ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
DXCC DIRECT EXPANSION COOLING COIL
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC EVAPORATIVE COOLER
ECC ENGINEERING CONTROL CENTER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EG EXHAUST GRILLE
EGS EMERGENCY GAS SHUTOFF
EGT ENTERING GLYCOL TEMPERATURE
EH EXHAUST HOOD
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ER EXHAUST REGISTER
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX. EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
F/SDPR COMBINATION FIRE SMOKE DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FCW FORWARD CURVED WHEEL (FAN)
FD FLOOR DRAIN
FD FIRE DAMPER
A/E ARCHITECT / ENGINEER
AAHX AIR TO AIR HEAT EXCHANGER
AAV AUTOMATIC AIR VENT
AB AIR BLENDER
ACC AIR COOLED CONDENSER
ACCH AIR COOLED CHILLER
ACCU AIR-COOLED CONDENSING UNIT
ACD AUTOMATIC CONTROL DAMPER, MODULATING
ACD-TP AUTOMATIC CONTROL DAMPER, TWO POSITION
ACFM ACTUAL CUBIC FEET PER MINUTE
ACU AIR CONDITIONING UNIT
AD ACCESS DOOR
AF AFTER FILTER
AFCV AIR FLOW CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AFW AIR FOIL WHEEL (FAN)
AHU AIR HANDLING UNIT
AMP AMPERE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE
AS AIR SEPARATOR
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AW AIR WASHER
AXF AXIAL FLOW
B BOILER
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BDR BASE BOARD RADIATOR
BFP BACKFLOW PREVENTER
BFT BOILER PLANT FIRE TUBE
BG BOTTOM GRILLE
BHP BRAKE HORSEPOWER
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT EXCHANGER
BIW BACKWARD INCLINED WHEEL (FAN)
BR BONE REGISTER
BSC BIOLOGICAL SAFETY CABINETS
BT BLOWOFF TANK
BTC BLOWOFF TANK CONTROL VALVE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BWT BOILER PLANT WATER TUBE
C CENTIGRADE (CELSIUS)
CC COOLING COIL
CCD COOLING COIL CONDENSATE DRAIN
CD CEILING DIFFUSER
CD-1 CONSTRUCTION DOCUMENTS (SUBMISSION 1)
CD-2 CONSTRUCTION DOCUMENTS (SUBMISSION 2)
CENT CENTRIFUGAL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFP CHEMICAL FEED PUMP
CFT CUBIC FEET
CG CEILING GRILLE
CH CHILLER
CHP CHILLED WATER PUMP
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CHW CHILLED WATER
CI CAST IRON
CM CARBON MONOXIDE
CM CUBIC METER
CO2 CARBON DIOXIDE
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
1. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT BARRIER AROUND
THE PROJECT AREA CONSISTENT WITH THE CONTRACTOR'S PHASING PLAN AS APPROVED BY
THE VA.
BAS BUILDING AUTOMATION SYSTEMS
1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A
FURRED CHASE OR ABOVE THE HARD SUSPENDED CEILING.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR
INDICATED. DUCT SIZES ARE NET INSIDE DIMENSIONS.
3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES,
TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE
FURNISHED AND INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS.
4. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM,
TERMINAL UNITS, FILTERS, COILS, ETC.
5. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO EQUIPMENT, SEE
EQUIPMENT DETAILS.
6. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES.
7. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE
TO PROVIDE COUNTER FLOW BETWEEN WATER AND AIR.
8. WALL TYPE EXHAUST REGISTERS NOTED AS "BR" ON DRAWINGS ARE TO BE
INSTALLED WITH BOTTOM ELEVATION OF REGISTER AT 7" ABOVE FINISHED FLOOR.
9. ALL PRESSURES LISTED ARE GAGE PRESSURE UNLESS NOTED OTHERWISE
10. ALL CONTROL SYSTEM EQUIPMENT SHALL BE COMPATIBLE WITH EXISTING
BUILDING MANAGEMENT SYSTEM CONTROLS. EXTEND EXISTING CONTROL SYSTEM
TO INCLUDE ALL OF THE CONTROLS AND SEQUENCES SHOWN.
11. COORDINATE EXISTING FIRE SPRINKLER HEADS AND LIGHTS WITH DIFFUSERS.
GENERAL NOTES
4/19/2019 MS MR
M-001
MECHANICAL ABBREVIATIONS &
GENERAL NOTES
ADDENDUM #1, NOTE #2 pg. M-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
04/22/2019 CONSULTANTS: ARCHITECT/ENGINEERS: STAMP:
VEG 18.15
568-18-102
VA MEDICAL CENTER - FT. MEADE, SD
UPGRADE NFS HVAC SYSTEM
FORT MEADE, SD
100% CONSTRUCTION
DOCUMENTS
DCV DEMAND CONTROL VENTILATION
TT
M
MT
PT
TT
FT
IT
CT
SPS
SD
PDT
KR
TSL
HS
ZC
LC
LT
PDS
TSH
EPT
AT
CO2
AT
CO
AT
OC
LTCP
HVAC
ECC
TC
VSMC
PC
SC
FC
PSH
FSH
PSL
CONTROLS SYMBOLS
DRAWING SYMBOLS
26-SF 3
26-TU-I-I
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
SUPPLY FAN NO. 3 IN BUILDING NO. 26
EQUIPMENT ABBREVIATION (SUPPLY FAN)
ITEM NUMBER (TERMINAL UNIT NO. 1)
ITEM (TERMINAL UNIT SHOWN)
SERVED BY AIR HANDLER UNIT NO. 1
DRAWING NUMBER WHERE DRAWN
BUILDING NO. WHERE EQUIPMENT IS LOCATED
H4
H7
A
DUCTWORK SYMBOLS
BDD
FD
VD
SUPPLY
RETURN
45°
45°
N
1/24
F/S DPR
GENERAL PIPING SYMBOLS
FE
AV
MV
SCH
SH
TH
PS
RC
WB
CSH
SS
* TYPE NUMBERS REFER TO MANUFACTURER'S STANDARDIZATION SOCIETY STANDARD PRACTICE SP-58
VR
CTPS
CTPD
FWPS
FWPD
CF
FWS
BWS
CBD
BO
TC
A
OFL
HW
SW
CW
FOR
FOS
LPG(I)
G(I)
G
HVAC PIPING SYMBOLS
HPS
HPR
MPS
MPR
LPS
LPR
PC
HWS
HWR
GHS
GHR
V
SWS
SWR
CWR
CHR
GCR
RL
RS
RHG
CWS
CHS
GCS
MW
D
GRR
GRS
X
TERMINAL UNIT SYMBOLS
A
PTAC
A
TWU
A
FCU
FCU
A
PTAC
A
AIR TERMINAL SYMBOLS
MB
KC
FSL
A
M
BAS
HIGH PRESSURE STEAM (60 PSIG AND ABOVE)
HIGH PRESSURE STEAM CONDENSATE RETURN
MEDIUM PRESSURE STEAM (16 PSIG THRU 59 PSIG)
MEDIUM PRESSURE STEAM CONDENSATE RETURN
LOW PRESSURE STEAM (15 PSIG AND BELOW)
LOW PRESSURE STEAM CONDENSATE RETURN
CONDENSATE PUMP DISCHARGE
HEATING WATER SUPPLY
HEATING WATER RETURN
GLYCOL-WATER HEATING SUPPLY
GLYCOL-WATER HEATING RETURN
SOLAR WATER SUPPLY
SOLAR WATER RETURN
REFRIGERANT LIQUID
REFRIGERANT SUCTION
REFRIGERANT HOT GAS
CONDENSER WATER SUPPLY (FROM TOWER)
CONDENSER WATER RETURN (TO TOWER)
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CHILLED GLYCOL-WATER SUPPLY
CHILLED GLYCOL-WATER RETURN
MAKE-UP WATER
DRAIN LINE
VENT LINE
GLYCOL-WATER RUN AROUND SUPPLY
GLYCOL-WATER RUN AROUND RETURN
EXISTING PIPE TO BE REMOVED
FEEDWATER PUMP DISCHARGE
FEEDWATER PUMP SUCTION
CONDENSATE TRANSFER PUMP DISCHARGE
CONDENSATE TRANSFER PUMP SUCTION
VACUUM CONDENSATE RETURN
TUBE CLEANER WATER SUPPLY
BOILER BLOWOFF
CONTINUOUS BLOWDOWN
BOILER WATER SAMPLE
FEEDWATER SAMPLE (FROM DEAERATOR)
CHEMICAL FEED
OVERFLOW
COMPRESSED AIR
NATURAL GAS MAIN FUEL
NATURAL GAS IGNITER FUEL
LIQUEFIED PETROLEUM GAS IGNITER FUEL
FUEL OIL SUPPLY
FUEL OIL RETURN
COLD WATER (CITY WATER)
SOFTENED WATER
HOT WATER
ROLLER-TYPE HANGER
VARIABLE SPRING-TYPE HANGER (TYPE 51)*
SPRING CUSHION-TYPE HANGER (TYPE 48 OR 49)*
CLEVIS-TYPE HANGER
TRAPEZE HANGER (PROVIDE U-BOLT PIPE ATTACHMENT
TO TRAPEZE EXCEPT WHERE RH ARE INDICATED)
FLOOR-SUPPORTED PIPE STAND
RISER CLAMP (TYPE 42)*
WALL BRACKET (TYPE 31, 32, 33)*
CONSTANT SUPPORT HANGER (TYPE 54, 55, 56)*
SLIDING SUPPORTS (TYPE 35)*
RH
DIRECTION OF PIPE PITCH (DOWN)
DIRECTION OF FLOW
ANCHOR
REDUCER OR INCREASER
ECCENTRIC REDUCER
TOP CONNECTION, 45° OR 90°
BOTTOM CONNECTION, 45° OR 90°
SIDE CONNECTION
CAPPED OUTLET
RISE OR DROP IN PIPE
UNION
PIPE UP
PIPE DOWN
INVERTED BUCKET TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
THERMOMETER
PRESSURE GAGE
FLOW ELEMENT
REFRIGERANT SIGHT GLASS
TEST PLUG (PRESSURE/TEMPERATURE)
AUTOMATIC AIR VENT
MANUAL AIR VENT
QUICK-COUPLE HOSE CONNECTOR
CONNECT TO EXISTING
LIMIT OF DEMOLITION
AIR SEPERATOR
TERMINAL UNIT WITH REHEAT COIL
DOUBLE DUCT MIXING BOX.
FAN POWERED VARIABLE VOLUME
TERMINAL UNIT WITH HEATING COIL.
EXISTING DUCT TO BE REMOVED
LOUVER (LOUVER SPECIFIED IN ARCHITECTURAL
SECTION.)
FLEXIBLE DUCTWORK (INSULATED)
DUCT WITH SOUND LINING
MANUAL VOLUME DAMPER
FIRE DAMPER
BACK DRAFT DAMPER
COMBINATION FIRE/SMOKE DAMPER
POINT OF CHANGE IN DUCT CONSTRUCTION BY
STATIC PRESSURE CLASS. THE NUMBER ASSIGNS
PRESSURE CLASS (IN. OF WATER) WHICH WILL
ACCOMMODATE MAXIMUM OPERATING PRESSURE
IN THE DUCT SUBSECTION. THE SYMBOL CONTINUES
THE ASSIGNMENT UNTIL THE DUCT TERMINATES OR
ANOTHER SYMBOL APPEARS. A "N" SUPERSCRIPT
INDICATES NEGATIVE PRESSURE.
AUTOMATIC CONTROL DAMPER MODULATING
AUTOMATIC CONTROL DAMPER TWO POSITION
MANUAL SPLITTER DAMPER
STANDARD BRANCH SUPPLY OR RETURN, NO
SPLITTER (45° TAP)
DUCT MOUNTED COIL (HOT WATER OR STEAM
COIL)
DUCT MOUNTED COIL (ELECTRIC)
CONVECTOR OR RADIATOR (RECESSED)
CONVECTOR OR RADIATOR (WALL HUNG)
FLOOR MOUNTED VERTICAL RECESSED FAN COIL UNIT.
LETTER INDICATES UNITSIZE.
FLOOR MOUNTED VERTICAL CABINET FAN
COIL UNIT. LETTER INDICATES UNIT SIZE.
THRU WALL AIR CONDITIONING UNIT.
LETTER INDICATES UNIT SIZE.
WINDOW TYPE AIR CONDITIONING UNIT.
LETTER INDICATES UNIT SIZE.
FLOOR MOUNTED HEAT PUMP. LETTER
INDICATES UNIT SIZE.
AIR CURTAIN
UNIT HEATER (HORIZONTAL)
UNIT HEATER (VERTICAL)
2'x2' RADIANT CEILING PANEL
2'x4' RADIANT CEILING PANEL
SUPPLY DUCT (UP & DOWN)
EXHAUST DUCT (UP & DOWN)
RETURN DUCT (UP & DOWN)
ROUND AND SQUARE 4-WAY CEILING DIFFUSERS
SQUARE 3-WAY CEILING DIFFUSERS
SQUARE 2-WAY CEILING DIFFUSERS
SQUARE 1-WAY CEILING DIFFUSERS
LINEAR SLOT DIFFUSER
SUPPLY TOP REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN CEILING
REGISTER OR GRILLE
EXHAUST OR RETURN BOTTOM
REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN REGISTER OR TOP GRILLE
(WALL TYPE)
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
CONNECT NEW DUCT TO EXISTING DUCT
INCLINED RISE, IN DIRECTION OF AIR FLOW
INCLINED DROP, IN DIRECTION OF AIR FLOW
LIMIT OF DEMOLITION
FLEXIBLE CONNECTION, EQUIPMENT, VIBRATION,
OR SEISMIC
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
VANED ELBOW (SHORT RADIUS)
STANDARD RADIUS ELBOW (LONG RADIUS)
NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
EXISTING DUCT TO REMAIN
DN
DN
UP
UP
D
R
DNUP
FC
10x8
LC
M
VALVE SYMBOLS
GATE VALVE - THREADED/FLANGED
GLOBE VALVE - THREADED/FLANGED
GATE VALVE WITH 3/4" HOSE ADAPTER
CHECK VALVE
WYE STRAINER (WITH BALL VALVE & HOSE CONNECTION)
WYE STRAINER WITH VALVED DRAIN AND QUICK-COUPLE
FLEXIBLE CONNECTION
ANGLE GLOBE VALVE
BUTTERFLY VALVE
BALL VALVE
MODULATING CONTROL VALVE
MODULATING CONTROL BUTTERFLY VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
THREE-WAY TWO POSITION CONTROL VALVE
PRESSURE REGULATING VALVE
PRESSURE SAFETY VALVE
AUTOMATIC BALANCING CONTROL VALVE
WATER BALANCE DEVICE
CIRCUIT SETTER VALVE
GATE VALVE WITH GLOBE-VALVED BYPASS
PLUG VALVE
CONTROL VALVE (CV) - FLOAT-OPERATED
PRESSURE REDUCING VALVE (PRV)
WATER LEVEL CONTROLLER
FLOW METER
ROOM THERMOSTAT/TRANSMITTER - WALL MOUNT
ROOM HUMIDISTAT (MOISTURE)/TRANSMITTER - WALL
MOUNT
TEMPERATURE TRANSMITTER
TEMPERATURE TRANSMITTER, AVERAGING ELEMENT
MOISTURE (HUMIDITY) TRANSMITTER
PRESSURE TRANSMITTER
STATIC PRESSURE SENSOR
FLOW TRANSMITTER
CURRENT TRANSMITTER
CONDUCTIVITY TRANSMITTER
SMOKE DETECTOR
PRESSURE DIFFERENTIAL TRANSMITTER
PRESSURE DIFFERENTIAL SWITCH
HAND SWITCH (HAND-OFF-AUTO SWITCH)
VALVE OR DAMPER POSITION CONTROLLER
LOCAL RECORDING TIME CLOCK (RUNTIME)
TEMPERATURE SWITCH, LOW (FREEZESTAT)
TEMPERATURE SWITCH, HIGH (FREEZESTAT)
LEVEL CONTROLLER
LEVEL TRANSMITTER
PRESSURE SWITCH HIGH
PRESSURE SWITCH LOW
ELECTRONIC TO PNEUMATIC TRANSDUCER
CARBON DIOXIDE TRANSMITTER
CARBON MONOXIDE TRANSMITTER
OCCUPANCY SENSOR
LOCAL TEMPERATURE CONTROL PANEL
HVAC CONTROL PANEL
VARIABLE SPEED MOTOR CONTROLLER
INTEGRATE CONTROL POINT ON REMOTE
GRAPHICS WORKSTATION AT ENERGY
CONTROL CENTER
TEMPERATURE CONTROLLER. SEE
SEQUENCE OF OPERATION
PRESSURE CONTROLLER. SEE SEQUENCE
OF OPERATION
SPEED CONTROLLER. SEE SEQUENCE OF
OPERATION
FLOW CONTROLLER. SEE SEQUENCE OF
OPERATION
FLOW SWITCH HIGH
FLOW SWITCH LOW
TIME CLOCK CONTROLLING EQUIPMENT ON
A SCHEDULE
TEMPERATURE SENSING ELEMENT FOR
TRANSMITTING TEMPERATURE TO EMCS
(PROVIDE 12 INCHES MINIMUM
LENGTH IN DUCT WHEN SPACE PERMITS.)
SENSOR WITH AVERAGING ELEMENT
TO TRANSMIT TEMPERATURE TO EMCS
MOTOR STARTER
ELECTRIC OPERATED CONTROL
DAMPER OR VALVE
BUILDING AUTOMATION SYSTEM
4/19/2019 MS MR
M-002
MECHANICAL SYMBOLS
ADDENDUM #1, NOTE #2 pg. M-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
04/22/2019 CONSULTANTS: ARCHITECT/ENGINEERS: STAMP:
VEG 18.15
568-18-102
VA MEDICAL CENTER - FT. MEADE, SD
UPGRADE NFS HVAC SYSTEM
FORT MEADE, SD
100% CONSTRUCTION
DOCUMENTS
R100
101A
106D1
108107A
106D2
107B
106C
106A
104A
106B
C102
105A
118 116B
119A
C100
EXTERNAL INSULATION
S-1
OFFICE
PATIENT DINING ROOM
MEN'S LOCKER ROOM
ADMIN. AREA
WOMEN'S LOCKER ROOM
OFFICE
POT/PAN WASHER AREA
STORAGE
CANTEEN
DISH
ROOM
COOK'S WALK-IN COOLER NON-FOOD STORAGE
CANTEEN KITCHEN
OFFICE STORAGE
KITCHEN EQUIPMENT ROOM
SHELVING
REFRIG
REST. RM.
STORAGE
NFS DISH ROOM
MAT. WASH
CANTEEN DINING ROOM
REFRIG
/10
D-4
45/16 38/16 32/16 24/16 24/6 15N
15'-0"
S
45/7
/12
/12
/12
/12
15'-0"
S
36/8
45'-0"
S
16/12 16/12 16/12 16 /12
50/12
/12
38/12
12/12
13/12
38/12 25/12 14/12 16/12
13/12
45'-0"
S
ADDENDUM #1, NOTE #2 pg. M-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
04/22/2019 CONSULTANTS: ARCHITECT/ENGINEERS: STAMP:
VEG 18.15
568-18-102
VA MEDICAL CENTER - FT. MEADE, SD
UPGRADE NFS HVAC SYSTEM
FORT MEADE, SD
100% CONSTRUCTION
DOCUMENTS
4/19/2019 MS RT
M-101
MECHANICAL 1ST FLOOR PLAN
D-4
D-4
D-4
INSULATE ALL SUPPLY DUCTWORK FROM AHU S-1 TO SUPPLY
PLENUMS AT GRILLES AND DIFFUSERS.
SHEET METAL BLANK-OFF 36" OF GRILLE FROM THE BACK SIDE
WITHIN PLENUM. PAINT FLAT BLACK PER SPEC SECTION 09 91 00
PAINTING.
VARIABLE FREQUENCY DRIVES FOR EXISTING EXHAUST FANS.
CONTROL PANEL
KEY NOTESKEY NOTES
150/15 50/19
8/16 8/16
8/16 9/16 24/6
24/10 23/1630/1637/1644/16
52/16 50/4
33/24
10/10
10/10
10/10
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
S-1 1ST FLOOR PLAN
N o r t h
N o r t h
DEDUCT ALTERNATE #1
COORDINATE FINAL
LOCATION WITH COR.
2 31 4 5 6
D
C
B
A
KEY PLAN
RLRSHG
RL
HGRS
RLRSHGRL
HGRS
RD
RD
RLRS
RLRS
A
B M
RL
RL
RS
RS
M M
RH
E
E
S-2 E
R
S-3 E
E
RT
E
CU
E
CC
E
S-1
8'-0"±
COORDINATE W/MECH. UNIT MANUF.
EQUAL EQUAL
T.O.TS-BEAM
NOTE:
CONTRACTOR TO FINISH
PAINT NEW SUPPORTS
AND FRAME.
3307'-1"
T.O.EXISTING
PLANK
NOTES:
· CONTRACTOR RESPONSIBLE FOR INSURING THAT ROOF DOES NOT LEAK
DURING ALL CONSTRUCTION OPERATIONS.
· AIR TEMPERATURE MUST BE AT OR ABOVE MINIMUM TEMPERATURES GIVEN BY
MANUFACTURER FOR EPOXY AND ROOFING.
· REPAIR ROOF AS REQUIRED WITH ROOFING SYSTEM COMPATIBLE WITH A
MECHANICALLY FASTENED TROCAL SINGLE PLY ROOFING MEMBRANE.
CU
E 1A
E
CC
NOTE:
REPAIR ROOF AS REQUIRED WITH ROOFING SYSTEM
COMPATIBLE WITH A MECHANICALLY FASTENED TROCAL
SINGLE PLY ROOFING MEMBRANE
4"
4"
12" MIN.
BUTT INSULATION AGAINST
CLAMP ASSEMBLY
SECURE PIPING TO SUPPORTS
WITH "HYDRA-ZORB",
"CUSH-A-CLAMP" OR EQUAL. (TYP.)
1/4" FILLET WELD PIPE SADDLE SUPPORT TO PIPE.
PROVIDE WATER TIGHT CONNECTION
SEALANT
PRE-MOULDED FLEXIBLE
PIPE COUNTER FLASHING
CLAMPING RING
ROOF SYSTEM INSULATION
AND MEMBRANE
CONCRETE ROOF SLAB OR
STEEL ROOF DECK
SECURE TO ROOF SLAB WITH
(4) 3/8" DIA. EXPANSION BOLTS
CONTRACTOR TO FINISH
PAINT NEW SUPPORTS
INSULATION
1-5/8" P-1000 "UNISTRUT"
CHANNEL OR EQUAL. (TYP.)
1/4" FILLET WELD ALL AROUND
ROOF
SURFACE
8"x8"x5/16" STEEL PLATE
1/4" FILLET WELD PLATE TO PIPE
ADDENDUM #1, NOTE #2 pg. M-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
04/22/2019 CONSULTANTS: ARCHITECT/ENGINEERS: STAMP:
VEG 18.15
568-18-102
VA MEDICAL CENTER - FT. MEADE, SD
UPGRADE NFS HVAC SYSTEM
FORT MEADE, SD
100% CONSTRUCTION
DOCUMENTS
4/19/2019 MS RT
M-102
MECHANICAL ROOF AND
PENTHOUSE PLAN
SHEET METAL FILLER
COIL SUPPORT
113-13/16"
88-5/16"
TS-BEAMS - SEE PLAN
ALL TS5"x5"x1/4" CONNECTIONS
(BEAMS & COL.) TO EACH OTHER
TO BE FULL PENETRATION
FLARE-BEVEL WELDS
CURB FOR MECHANICAL UNIT
AS PER MANUFACTURER
WELD TO FRAME (C8X11.5)
TS-COL. (A5000 GRADE B OR C) - SEE PLAN
PROVIDE 12"x12"x1/4" BASE PLATE (A36
GRADE) W/(4)7/8"Ø-9X16" A307 THREADED
ROD DRILLED & SET INTO EXISTING CONC.
BEAM W/HILTI-HY15O EPOXY MINIMUM
EMBEDMENT INTO EXISTING CONC. BEAM
10" (EPOXY INSTALLATION AS PER MANUF.
REQUIREMENTS) DO NOT CUT ANY
EXISTING CONC. BEAM REINFORCEMENT
ALSO PROVIDE 2" NON-SHRINK GROUT
(7,000 PSI) UNDER BASE PLATE
EXISTING BAR JST.
SEE PLANEXISTING CONC. BEAM
SEE PLAN
EXISTING BAR JST.
SEE PLAN
EXISTING 2" CONC. PLANK
FLASHING BOOT - SEAL
TO COLUMN & ROOF BY
ROOFING CONTRACTOR
SCALE: NO SCALE
DETAIL FOR SUPPORTING PIPE ON ROOF
B1
SCALE: NO SCALE
CU-2 SECTION A-A
D1
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
CU-2 ROOF SUPPORT PLAN
F1
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
S-1 SECTION B
F5
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
S-1 SECTION A
E5
12"
D
E
2 3
A A
8'- 0"
10'-0"±
A A
C
TOP OF EXISTING
2" PLANK 3307'-1"
EXISTING
PENTHOUSE
TS5"x5"x1/4" EXISTING 12"x18" CONC.BEAM
EXISTING CONC. COL. BELOW
EXISTING CONC.
COL. BELOW
EXISTING CONDENSER
SUPPORT
EXISTING 14S5 BAR
JOISTS @ 4'-0" C.C.
FIELD VERIFY
15"
AP
PR
OX
APPROX 98"
PIPING SPACE
MAINTAIN EXISITNG
CLEARANCE
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
S-1 ROOF AND PENTHOUSE PLAN
D5
CATWALK
INSULATE ALL SUPPLY DUCTWORK FROM AHU S-1 TO
SUPPLY PLENUMS AT GRILLES AND DIFFUSERS.
PROVIDE PIPING SUPPORTS ON ROOF. (MINIMUM 12" ABOVE
ROOF)
SIZE REFRIGERANT PIPING AS PER MANUFACTURE'S
RECOMMENDATIONS.
FLEXIBLE PIPE CONNECTORS (TYPICAL)
RELOCATE EXISTING ROOFING PAVERS, AS REQUIRED, FOR
NEW CONDENSING UNIT. PROVIDE APPROXIMATELY 10 NEW
PAVERS TO CIRCLE NEW CONDENSING UNIT. INSTALL
PAVERS AND MEMBRANE PAD IN ACCORDANCE WITH
COMPATIBLE ROOFING SYSTEM. COORDINATE WITH OWNER
PRIOR TO BID.
ELECTRICAL CONTRACTOR SHALL PROVIDE SPARE BUCKET
AND PROVIDE NEMA 5, 208V, 3-PHASE STARTER IN BUCKET
OF MCC-106. ELECTRICAL CONTRACTOR SHALL ALSO
PROVIDE (3-300KCMIL, & 1#2G) 3”C FROM MCC-106 BUCKET
WITH NEW NEMA 5 STARTER TO CONTROL CABINET OF NEW
CU-2
KEY NOTESKEY NOTES
SHEET METAL FILLER
SHEET METAL FILLER
DRAIN PAN
(SLOPE TO DRAIN)
COIL SUPPORT
COIL SUPPORT
1-1/4" CONDENSATE TO
DRAIN PROVIDE TRAP
2 3 4 5
D
C
EXISTING
MCC-106
EXISTING
PANEL P-105
KEY NOTES
GENERAL NOTES
1. STRUCTURAL DESIGN CRITERIA INCLUDES A ROOF DEAD LOAD OF 20
PSF, SNOW LOAD OF 25 PSF PLUS SNOWDRIFT Is=1.2, WIND SPEED
OF 120 MPH EXPOSURE B, AND A SEISMIC RISK CATEGORY IV -
CRITICAL FACILITY Ie=1.5.
N o r t h
N o r t h
DRAIN PAN
N o r t h
KEY PLAN
DEDUCT ALTERNATE #1
VFD FOR SF-1
DEDUCT ALTERNATE #1
DEDUCT ALTERNATE #2
CONVERT ALL AHU S-1
PNEUMATIC CONTROLS TO
DIGITAL OR ELECTRONIC.
CC
CC
WALL MOUNTED CONTROL SYSTEM
1 E
1A
FANSLIGHTS
TYPICAL HOOD CONTROL PANEL INSTALLATION
TYPICAL INTERFACE CONTROL
ELECTRICAL PACKAGE
1 DCV-2111 WALL MOUNT IN SS BOX 05 - SS WALL MOUNT
BOX
1 LIGHT
1 FAN
SMART CONTROLS DCV
EXHAUST
EXHAUST
3.000 3.000
9.5 9.5
NO. TAG PACKAGE # LOCATION SWITCHES
LOCATION QUANTITY
OPTION FANS CONTROLLED
TYPE ɸ H.P. VOLT FLA
BASIS OF DESIGN IS CAPTIVEARE. PANEL SCHEMATICS ARE FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO PROVIDE 120V 15A CONNECTION. WIRE PER MANUFACTURER RECOMMENDATION.
HOOD CONTROL PANEL- DEMAND CONTROL VENTILATION (DCV) CONTROLS
WRITTEN SPECIFICATIONS: THE HOOD CONTROL PANEL WITH DEMAND CONTROL VENTILATION AUTOMATICALLY MODULATES FANS BASED ON COOKING LOAD. MODULATION ALLOWS FOR ENERGY SAVINGS
COMPARED TO FANS RUNNING ON HIGH SPEED DURING COOKING OPERATION.
LISTINGS: THE MODEL'S ELECTRICAL CONTROL PANEL ARE ETL LISTED UNDER FILE NUMBER 101754591COL-001 AND COMPLIES WITH UL508A STANDARDS AND CAN/CSA C22.2, NO. 14-05 STANDARDS.
ECPM03 CIRCUIT BOARD IS ETL LISTED UNDER FILE NUMBER 100901773BOX-001 AND COMPLIES WITH UL 61010-1 STANDARD AND CAN/CSA C22.2, NO. 61010-1 STANDARDS.
SEQUENCE OF OPERATIONS: THE HOOD CONTROL PANEL INTERLOCKS THE 2 EXHAUST FANS WITH THE MAKEUP AIR UNIT. (S-1) THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE
FOLLOWING STATES AT ANY GIVEN TIME:
AUTOMATIC: THE DCV HOOD CONTROL PACKAGE IS DESIGNED TO THERMOSTATICALLY ACTIVATE THE EXHAUST FANS AND MAKE-UP AIR FOR AN EXHAUST HOOD WHENEVER ELEVATED TEMPERATURES ARE SENSED IN THE EXHAUST SYSTEM. THIS OPTION WILL MEET THE REQUIREMENTS OF IMC 507.1.1 AND IMC 508.1 BY PROVIDING A THERMOSTAT(S) MOUNTED IN THE DUCT OR HOOD RISER TO SENSE
INCREASED EXHAUST TEMPERATURES.
ONCE THE DUCT TEMPERATURE REACHES THE ACTIVATION POINT, THE EXHAUST FANS AND MAU WILL BE ACTIVATED. THE CONTROLS ALSO PROVIDE HYSTERESIS TO PREVENT CYCLING OF THE FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND THE HEAT IN THE EXHAUST SYSTEM IS REDUCED. THE HYSTERESIS IS FACTORY SET 2 DEGREES AND WILL KEEP THE EXHAUST RUNNING UNTIL THE TEMPERATURE FALLS 2 DEGREES BELOW THE ACTIVATION SET POINT. A HYSTERESIS TIMER ALSO EXISTS TO KEEP THE FANS RUNNING FOR AT LEAST 30 MIN AFTER BEING ACTIVATED BY THE
TEMPERATURE RISE.
THE PANEL IS FACTORY CONFIGURED TO SHUT DOWN SUPPLY FANS, TURN ON THE EXHAUST FANS AND TURN OFF THE HOOD LIGHTS IN A FIRE CONDITION.
THE DCV TURNS DOWN TO 20-25% OF TOTAL EXHAUST IN PREP MODE. THE SYSTEM IS CAPABLE OF TURNING DOWN TO 0% WHEN OPERATING AUTOMATICALLY IF IT DOES NOT SENSE A NEED FOR HOOD OPERATION. THE DCV WILL MODULATE THE FANS IT IS CONTROLLING BASED ON DEMAND AND THE LOW SPEED AND HIGH SPEED SETTINGS ARE FULLY ADJUSTABLE BASED ON DEMAND.
IN THE EVENT OF A FIRE, THERE ARE TWO FORMS OF ACTIVATION. THE MECHANICAL REMOTE PULL MAY BE ACTIVATED OR THE MECHANICAL DETECTION LINK IN THE HOOD MAY MELT. THE ANSUL AUTOMAN TAKES THIS MECHANICAL ACTIVATION AND CONVERTS IT TO AN ELECTRIC NOTIFICATION SIGNAL VIA THE MICROSWITCH AND BUILDING-INITIATING SWITCH. IN EITHER EVENT, THE DCV WILL BE ELECTRICALLY NOTIFIED VIA THE ANSUL AUTOMAN. THE DCV WILL THEN TURN ON THE EXHAUST FAN, TURN OFF THE MAKE-UP AIR UNIT AND TURN OFF THE HOOD LIGHTS. THE ANSUL AUTOMAN WILL CLOSE THE MECHANICAL GAS VALVE TO CLOSE THE GAS LINE OR, IF AN ELECTRIC GAS VALVE IS USED, THE HOOD CONTROL PANEL WILL SEND A SIGNAL TO THE SHUNTED PORTION OF THE BREAKER PANEL TO REMOVE POWER FROM THE COOKING APPLIANCES. THE BUILDING-INITIATING SWITCH CAN BE USED TO NOTIFY THE BUILDING ALARM SYSTEM.
MANUAL: THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI.
SCHEDULE: A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE DAY. THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED.
OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BAS OR HARD-WIRED INTERLOCK) ADDENDUM #1, NOTE #2 pg. M-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
04/22/2019 CONSULTANTS: ARCHITECT/ENGINEERS: STAMP:
VEG 18.15
568-18-102
VA MEDICAL CENTER - FT. MEADE, SD
UPGRADE NFS HVAC SYSTEM
FORT MEADE, SD
100% CONSTRUCTION
DOCUMENTS
4/19/2019 MS RT
M-200
MECHANICAL HOOD CONTROLS
DESCRIPTION OF OPERATION:
EFC1
EFO1
COMMON
NORMALLY OPEN
EFC2
EFO2
COMMON
NORMALLY OPEN
CONTROL PANEL
ON/OFF WITH
DRY CONTACT
EXHAUST FAN
GROUP 1
H1
IO1
BMS SWITCH
C NOCONTROL PANEL
EXTERNAL
TO
SWITCH
VFD ANALOG
(EACH VFD)
0-10V OUTPUT
IN VFD
TO BMS
VO+
VO-
DCV SPEED
(TOTAL)
0-10V OUTPUT
ON PCB
TO BMS
SFC1
SFO1
COMMON
NORMALLY OPEN
SFC2
SFO2
COMMON
NORMALLY OPEN
CONTROL PANEL
ON/OFF WITH
DRY CONTACT
SUPPLY FAN
GROUP 1
C2
AR2
COMMON
NORMALLY OPEN
SYSTEM DRY
SPARE FIRE
CONTACT
CONTROL PANEL
ST
N1 NEUTRAL FROM SHUNT COIL
HOT TO SHUNT COIL SHUNT COIL
CONTROL PANEL
EXTERNAL
SIGNAL FOR
SHUNT TRIP
ST TERMINAL IS ENERGIZED
IN FIRE CONDITION.
THE FOLLOWING CONNECTIONS
MAY OR MAY NOT BE
REQUIRED BASED ON JOBSITE
SPECIFICATIONS
T3A
T3B SHIP LOOSE
DUCT STAT
CONTROL PANEL
DUCT SENSOR
TO
T2A
T2B SHIP LOOSE
DUCT STAT
CONTROL PANEL
DUCT SENSOR
TO
T1A T1B
ROOM TEMP
CONTROL PANEL
KITCHEN TEMP
TO
SENSOR
ROUTERCOMM CAT-5 ETHERNET CONNECTION
CONTROL PANEL
WORLD WIDE
TO
WEB
B1 W1
GND
BLACK
WHITE
GREEN
HOOD LIGHTS 1
CONTROL PANEL
HOOD LIGHTS
TO
1400 W MAX WIRE TO J-BOX ON TOP OF HOOD
J4
ALL SWITCHES FACTORY WIRED
CAT-5 CONNECTION
CONTROL PANEL
SWITCHES
TO
C1
AR1
MICROSWITCH 1
1:C
4:NO
2:NC
MS-1
1:C
4:NO
2:NC
1:C
4:NO
2:NC
MS-2
C1
AR1
WIRE C1 TO COMMON (1).
C1 TO AR1 SHOULD HAVE
CONTROL PANEL
FIRE SYSTEM
TO
MICROSWITCH
CONTINUITY WHEN ARMED.
WIRE AR1 TO NORMALLY CLOSED (2).
CAP
OFF
CAP
OFF
CAP
OFF
CONTROL PANEL TO ACCESSORY ITEMS
Responsibility: Electrician
CONTROL PANEL COMPONENT
IL1A
IL1B
D3 D7
MAKE UP AIR
PROVING
INTERLOCK
DAMPER
MUA ZONE 1ON PCB
REMOVE JUMPER
SUP-3
N1 120V NEUTRAL
120V HOT
N1
SF1
-- WHITE
REDCONTROL PANEL
INTERLOCK
SUPPLY FAN
V1+ V1-
SUP-3
FAN: 03
RED(+)
BLACK(-)
RED(+)
BLACK(-)
SHIELDED TWISTED PAIR
0-10 VDC
SPEED SIGNAL
CONTROL
NOTE: 0-10 VDC SIGNAL IS
POLARITY SENSITIVE.
OUTDOOR RATED
EF-202LOAD LEG 1
LOAD LEG 2
GND GROUND
FAN:
SM-2 LOAD LEG 3
U2 V2 W2
9.5 3.000
208 V
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
EF-101LOAD LEG 1
LOAD LEG 2
GND GROUND
FAN:
SM-1 LOAD LEG 3
U1 V1 W1
9.5 3.000
208 V
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
CONTROL PANEL TO FANS
Responsibility: Electrician
PRIMARY PANEL FANS
LINE
LINE
Ground
EF-2 SM-2
GND
L4
L5LINE L6208 V
11.9 A
20 A
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
LINE
LINE
Ground
EF-1 SM-1
GND
L1
L2LINE L3208 V
11.9 A
20 A
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
Hot Neutral H1
N1120 V 15 A
Ground GND
BREAKER 1PH
BREAKER PANEL TO PRIMARY CONTROL PANEL
Responsibility: Electrician
BREAKER PANEL PRIMARY CONTROL PANEL
BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED
Fort Meade, SD- DCV Retrofit
DCV-2111 INSTALLJOB NO
JOB NAME
MODEL NUMBER SCHEMATIC TYPE
CONTROL POWER. DO NOT WIRE
TO GFCI OR SHUNT TRIP BREAKER.
1ST HOOD LIGHT BREAKER SHARED W/
CONTROL POWER. SWITCH #1
IF MORE THAN ONE
FIRE SYSTEM, WIRE IN
SERIES AS SHOWN
TERMINAL
NAMES DO NOT
APPLY IF MUA
BY OTHERS
HOOD LIGHTS
EXISTING HOOD
ROOM TEMPERATURE
SENSOR
DUCT TEMPERATURE SENSOR
DUCT TEMPERATURE SENSOR
FIELD WIRING
CASLINK MONITOR AND CONTROL
MONITORING AND CONTROL POINTS LIST
DCV PACKAGES FUNCTION
ROOM TEMPERATURE MONITOR
DUCT TEMPERATURE(S) MONITOR
MUA DISCHARGE TEMPERATURE MONITOR
KITCHEN RTU DISCHARGE TEMP. MONITOR
FAN SPEED (2) MONITOR
FAN AMPERAGE (2) MONITOR
FAN POWER (2) MONITOR
VFD FAULTS (2) MONITOR
CONTROLLER FAULTS MONITOR
FAN FAULTS (2) MONITOR
FAN STATUS (2) MONITOR
PCU FAULTS MONITOR
PCU FILTER CLOG PERCENTAGES MONITOR
FIRE CONDITION MONITOR
CORE FIRE SYSTEM MONITOR
BUILDING PRESSURES MONITOR
PREP TIME BUTTON MONITOR & CONTROL
FANS BUTTON MONITOR & CONTROL
LIGHTS BUTTON MONITOR & CONTROL
FIELD CONNECTION TO ROUTER OR ETHERNET SWITCH
OR FACTORY WIRED CONNECTION TO CELLULAR KIT
- HOOD CONTROL PANEL TO SUPPORT COMMUNICATIONS TO
BUILDING MANAGEMENT SYSTEM.
- HOOD CONTROL PANEL TO ALLOW BUILDING MANAGEMENT
SYSTEM TO MONITOR REAL TIME PARAMETERS OUTLINED AS
MONITOR IN THE POINTS LIST.
- HOOD CONTROL PANEL TO ALLOW BUILDING MANAGEMENT
SYSTEM TO CONTROL PARAMETERS OUTLINED AS CONTROL IN THE
POINTS LIST.
- HOOD CONTROL PANEL TO ALLOW REMOTE CHANGES TO
SYSTEM SETTING SUCH AS: VFD FREQUENCIES, ECM SPEEDS,
TEMPERATURE SET POINTS, FAN SCHEDULES, ETC.
120V CONNECTION
DEMAND CONTROL VENTILATION, W/ CONTROL FOR 2 EXHAUST FANS, 1 SUPPLY FAN, EXHAUST ON IN FIRE, LIGHTS OUT IN FIRE, FANS MODULATE BASED ON DUCT TEMPERATURE. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. ROOM TEMPERATURE SENSOR SHIPPED LOOSE FOR FIELD INSTALLATION.VERIFY DISTANCE BETWEEN VFD AND MOTOR; ADDITIONAL COST COULD APPLY IF DISTANCE EXCEEDS 50 FEET.
LOW VOLTAGE CONNECTION FOR
DAMPER INTERLOCK. WIRE MULTIPLE
SUPPLY ON THE SAME ZONE IN
SERIES. SHOULD HAVE CONTINUITY
WHEN DAMPER IS PROVEN OPEN.
NOT REQUIRED FOR ALL UNITS. SEE
MAKE-UP AIR SCHEMATIC.
SPARE CONTACTS WILL MAKE C2 TO
AR2 WHEN SYSTEM IS ARMED. THEY
ARE USED TO DISABLE EQUIPMENT
OR PROVIDE SIGNALS. (NOT FOR
BUILDING FIRE ALARM WHICH MUST
BE WIRED DIRECTLY TO THE ANSUL
ALARM INITIATING SWITCH LOCATED
IN ANSUL AUTOMAN)
SPARE CONTACTS WILL MAKE
COMMON TO NORMALLY OPEN
WHEN SUPPLY FAN IS ON.
WIRE TO ECPM03 TERMINALS.
CONFIGURABLE OUTPUT. SEE
ECPM03 OWNERS MANUAL.
WIRE TO VFD TERMINAL STRIP.
PROPORTIONAL TO FREQUENCY.
SEE VFD OWNERS MANUAL.
SIGNAL SWITCH THROUGH BMS
WILL ACTIVATE ZONE1 FANS AND
LIGHTS
SPARE CONTACTS WILL MAKE
COMMON TO NORMALLY OPEN
WHEN EXHAUST FAN IS ON.
WIRE DIRECTLY TO COMMUNICATION
MODULE. NET REQUIRES 1) DHCP 2)
UDP PORT 1444 & 1445 OPEN FOR
OUTBOUND TRAFFIC ONLY.
WIRE TO CONTROL BOARD. INSTALL
SENSOR IN ROOM AWAY FROM HEAT
SOURCES. DO NOT INSTALL SENSOR
ON THE CEILING GRID, SEE MANUAL.
WIRE TO CONTROL BOARD. SENSOR
MOUNTED IN EXHAUST DUCT
WIRE TO CONTROL BOARD. SENSOR
MOUNTED IN EXHAUST DUCT
MUST HAVE ITS OWN METAL
CONDUIT. WIRE TO PROVIDED
CONDUIT DROP. NOT
REQUIRED FOR ALL UNITS. SEE
MAKE-UP AIR SCHEMATIC.
ALL DRAWING
CONTENTS ARE FOR
DEDUCT ALTERNATE #1
| Sheets and Views |
| 568-18-102 G-001-G-001 |
| 568-18-102 M-001-M-001 |
| 568-18-102 M-002-M-002 |
| 568-18-102 M-101-M101 |
| 568-18-102 M-102-M102 |
| 568-18-102 M-200-M-200 |
File details come from the government source that posted it.