Amendment 0003 - Attachment 2. 1CEXB Rev1.pdf

PDF 23 KB Posted

Attached to
Modernize Pathology Department, Bldg. 1 (VA-24-00001439)
Solicitation number
36C26223B0016_1
Issued by

About this file

This document is an electrical panel schedule for an emergency power panel located on the first floor north catwalk of Building 1. The panel is fed from distribution panel D1CEX and has a voltage rating of 120/208V with a capacity of 225 amps. It is a three phase panel manufactured by Eaton Electrical and was last revised in 2022. The panel has 18 spaces with 0 spares and provides power to various outlet and mechanical rooms on the first floor including rooms 1218A, 1220, 1240, and the first floor north corridor. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs to modernize the pathology department in Building 1 of the VA facility located in VISN 22 for a project numbered VA-24-00001439.

View the file

Other files

File Type Posted
Contract Award Notice_36C26223C0282.pdf PDF
Amendment 0003 - Attachment 9. 1XA.pdf PDF
Amendment 0003 - Attachment 21. DWGFINALSUBMITTAL.pdf PDF
Amendment 0003 - Attachment 16. Structural Drawings.pdf PDF
Amendment 0003 - Attachment 7. 1CEXM.pdf PDF
Amendment 0003 - Attachment 12. MCC.pdf PDF
Amendment 0003 - Attachment 22. Building 1 Fire Spinkler Valves 8.5x11.pdf PDF
Amendment 0003 - Attachment 3. 1CEXC Rev1.pdf PDF
Amendment 0003 - Attachment 20. MH-6.03 Rev01.pdf PDF
Amendment 0003 - Attachment 1. 1A Rev1.pdf PDF
Amendment 0003 - RFI Notice.pdf PDF
Amendment 0003 - Attachment 5. 1CEXG Rev1.pdf PDF
Amendment 0003 - Attachment 19. VA SD Master Finish Legend.pdf PDF
Amendment 0003 - Attachment 4. 1CEXF Rev1.pdf PDF
Amendment 0003 - Attachment 18. Grating and Fall Protection Railing Criteria.pdf PDF
Amendment 0003 - Attachment 14. Comprehensive Hazardous Materials Survey.pdf PDF
Amendment 0003 - Attachment 10. 1XAA Rev1.pdf PDF
Amendment 0003 - Attachment 11. 1XR Rev1.pdf PDF
Amendment 0003 - Attachment 13. Panel Photos.pdf PDF
Solicitation Amendment 0003 (SF30)_36C26223B0016 0003.pdf PDF
Amendment 0003 - Attachment 17. Record Drawings.pdf PDF
Amendment 0003 - Attachment 6. 1CEXGA Rev1.pdf PDF
Amendment 0003 - Attachment 15. 1st Floor PA.pdf PDF
Amendment 0003 - Attachment 8. 1CEXN.pdf PDF
S06 - Amendment 0002_ Att J. Pre-Bid Conference Site Visit Sign-in Sheet.pdf PDF
S06 - Solicitation Amendment 0002 (SF30)_36C26223B0016 0002.pdf PDF
S06 - Solicitation Amendment (SF30)_36C26223B0016 0001.pdf PDF
S02 - Att F. IFC Drawings 3.pdf PDF
S02 - Att A. Statement of Work_VASD Modernize Pathology.pdf PDF
S02 - Att H. Site Visit Map.pdf PDF
S02 - Att C. Specifications - VASD Modernize Pathology Project Manual_Vol 2.pdf PDF
S02 - Att E. IFC Drawings 2.pdf PDF
S02 - Att G. DB Wage Rates_GDN CA20230001 06.09.2023.pdf PDF
S02 - Att D. IFC Drawings 1.pdf PDF
S02 - Solicitation (SF1442)_36C26223B0016.pdf PDF
S02 - Att B. Specifications - VASD Modernize Pathology Project Manual_Vol 1.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Emergency Power Panel Card Panel Name: 1CEXB 1ST FLOOR NORTH CATWALK Voltage/Amps: 120/208V 225A Phase: 3 Fed From: D1CEX Bkrs: 18 Spaces: 0 Spares: 0 Make: Eaton Electrical Retro fit Revision Date:

Serial: AMP

Date Replace: AMP

1) OUTLET RM 1220 20

2) OUTLET RM 1220A,49B 20

3) OUTLET RM 1220 20

4) OUTLET RM 1220A 20

5) OUTLET RM 1220 20

6) OUTLET RM 1220A 20

7) OUTLET RM 1220,20A,49B 20

8) REFER RM 1220 20

9) OUTLET RM 1220,20A 20

10) OUTLET RM 1220 20

11) OUTLET RM 1220,20A 20

12) OUTLET RM 1220 20

13) SPARE RM ? 20A 20

14) ANALYIZER RM 1240 20

15) SPARE RM ? 20A 20

16) REFER RM 1220 30

17) CORRIDOR DOOR RM 1218A 20

18)

Eaton Electrical Inc.

Services & Systems 9610 Ridgehaven Court, Suite A San Diego, CA 92123 Tel: 858-514-2400

Electrical, Inc. Fax: 858-514-2410

Sheet1

File details come from the government source that posted it. Updated .