Amendment 0003 - Attachment 16. Structural Drawings.pdf
PDF 5 MB Posted
- Solicitation number
- 36C26223B0016_1
About this file
This package includes structural drawings and details for the modernization of the pathology department at a Veterans Affairs medical center. The project involves renovations to equipment anchorage, slab openings, and ductwork supports. Key equipment includes refrigerators, freezers, biosafety hoods, and air handlers. Structural details provide specifications for anchoring various medical devices to the building and installing isolators to reduce vibration transmission. The drawings also show framing requirements for openings in slabs to accommodate mechanical systems. Reinforcing and connection details are included. The solicitation number is listed as 36C26223B0016_1 and involves the Department of Veterans Affairs.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A R C H I T E C T
EXP I RES A UGUS T 3 1 , 2
0 2
1#C 14152
STATE
OF CA L I FORN
I A
ER
IC H . DAVY
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
08 - 6231
REVISIONS: DATE:NO.
664-18-333
BLDG #1
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLEREDFERNANDO ESTRELLA
JULY 09, 2021
PROGRAM DESIGN 20% 09/13/20191
REVIEWED IN ACCORDANCE
WITH THE REQUIREMENTS
OF CFM
BY: ____________________
DATE: ________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
SCHEMATIC DESIGN 35% 11/19/2019
MAJOR SYSTEMS 50% 12/19/2019
DESIGN DEVELOPMENT 65% 04/03/2020
CONSTRUCTION DOCUMENTS 95% 03/19/2021
CONSTRUCTION DOCUMENTS 100% 05/11/2021
IFC DOCUMENTS 07/09/2021
MODERNIZE PATHOLOGY DEPT., BLDG. 1GENERAL INFORMATION NOTES
JM / JT RA / LL
1870 Cordell Court, Suite 202 El Cajon, CA 92020 tel 619 312 6336 aarkengineering.com
R
Exp. 6/30/2022
NE
TA
S
T
FO
ACOF LI
R R
AI
L
OSOR FE SI
T I
EG
S
DE
ER
P
No. 4948
J
NA
GI
E
RE
N
EN
TS
U C
A
AR
ON
AMES STEELE
T U RAL
AS EL
GENERAL STRUCTURAL NOTES
& AND
@ AT
# POUND(S),
NUMBER
AB ANCHOR BOLT
ABV ABOVE
ADDL ADDITIONAL
ALT ALTERNATE
ALUM ALUMINUM
ANCH ANCHOR
APPROX APPROXIMATE(LY)
AR ANCHOR ROD
ARCH ARCHITECTURAL
ASSY ASSEMBLY
BEL BELOW
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BN BOUNDARY
NAILING
BOT BOTTOM
BOTT BOTTOM
BRG BEARING
BTWN BETWEEN
CANT CANTILEVER
CBC CALIFORNIA
BUILDING CODE
CIP CAST-IN-PLACE
CJ CONSTRUCTION
JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE
MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CTR CENTER
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DO DITTO
DWG DRAWING
DWL DOWEL
(E) EXISTING
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATION
EMB EMBEDMENT
EMBED EMBEDMENT
EN EDGE/END
NAIL(ING)
EQ EQUAL
ETC ET CETERA
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FF FINISH FLOOR
FG FINISH GRADE
FIN FINISH
FLR FLOOR
FN FIELD NAIL(ING)
FND FOUNDATION
FOC FACE OF
CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FRMG FRAMING
FT FOOT
FTG FOOTING
FV FIELD VERIFY
GA GAGE
GALV GALVANIZE(D)
GLB GLUE-LAMINATED
BEAM
GR GRADE
HDG HOT DIPPED
GALVANIZED
HGR HANGER
HK HOOK
HORIZ HORIZONTAL
HSB HIGH STRENGTH
BOLT
HSS HOLLOW STEEL
SECTION
HT HEIGHT
ID INSIDE DIAMETER
INSP INSPECTION
INT INTERIOR,
INTERNAL
JST JOIST
JT JOINT
LB POUND
LBS POUNDS
LG LONG
LDH LONG DIMENSION
HORIZONTAL
LDV LONG DIMENSION
VERTICAL
LONG LONGITUDINAL
LSL LAMINATED
STRAND
LUMBER
LW LIGHTWEIGHT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MF MOMENT FRAME
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY
OPENING
MTL METAL
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
NW NORMAL WEIGHT
OC ON CENTER
OD OUTSIDE
DIAMETER
OFCI OWNER
FURNISHED,
CONTRACTOR
INSTALLED
OFOI OWNER
FURNISHED,
OWNER
INSTALLED
OH OPPOSITE HAND
OPN OPEN
OPNG OPENING
ORIG ORIGINAL
OWJ OPEN WEB JOIST
PAF POWER ACTUATED
FASTENER(S)
PC PRECAST
CONCRETE
PCC PORTLAND
CEMENT
CONCRETE
PL PLATE
PT PRESSURE
TREATED
PTDF PRESSURE
TREATED
DOUGLAS FIR
PVC POLYVINYL
CHLORIDE
PE POLYETHYLENE
PERP PERPENDICULAR
PLF POUNDS PER
LINEAL FOOT
PSF POUNDS PER
SQUARE FOOT
PSI POUNDS PER
SQUARE INCH
PREFAB PREFABRICATE(D)
R RADIUS
RAD RADIUS
REINF REINFORCED,
REINFORCING
REQD REQUIRED
RET RETAINING
SC SCALE
SCHED SCHEDULE
SCW SCREW
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SMS SHEET METAL
SCREW
SP SPECIAL
SPCG SPACING
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUC STRUCTURAL
SYMM SYMMETRICAL
T&B TOP AND BOTTOM
T&G TONGUE AND
GROOVE
THD THREAD(ED)
THK THICK(NESS)
THR THREAD(ED)
THRU THROUGH
TN TOE NAIL
TP TOP OF PANEL
TRANSV TRANSVERSE
TYP TYPICAL
UON UNLESS
OTHERWISE
NOTED
VAR VARIES
VFCI VENDOR
FURNISHED,
CONTRACTOR
INSTALLED
VFVI VENDOR
FURNISHED,
VENDOR
INSTALLED
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
WP WATERPROOFING,
WORKING POINT
WPJ WEAKENED PLANE
JOINT
WS WATERSTOP
WSHR WASHER
WT WEIGHT
STRUCTURAL ABBREVIATIONS
S-0.1
GENERAL
1. ALL WORK SHOWN ON THESE DRAWINGS SHALL BE CONSIDERED NEW WORK, UNLESS OTHERWISE
NOTED.
2. ALL WORK AND MATERIALS SHOWN ON THESE DRAWINGS SHALL BE FURNISHED AND INSTALLED BY THE
CONTRACTOR, UNLESS OTHERWISE NOTED.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING WORK. THE DESIGN
PROFESSIONAL OF RECORD SHALL BE NOTIFIED OF ANY DISCREPANCIES FOUND.
4. IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS OR DETAILS ON THE
DRAWINGS.
5. BEFORE COMMENCING EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING UNDERGROUND UTILITIES, VALVE PITS OR VAULTS AND SHALL NOT PERFORM WORK THAT WILL DAMAGE
THEM OR INTERFERE WITH THEIR SERVICE.
6. STRUCTURAL DIMENSIONS CONTROLLED BY OR RELATED TO ARCHITECTURAL APPURTENANCES OR MECHANICAL, PLUMBING OR ELECTRICAL EQUIPMENT SHALL BE VERIFIED BY THE CONTRACTOR PRIOR
TO FABRICATION OR CONSTRUCTION.
7. THE CONTRACT STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT
INDICATE METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES
NECESSARY TO PROTECT EXISTING AND NEW STRUCTURES DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING, ET CETERA FOR ALL CONSTRUCTION
PHASE LOADS.
8. ALL EQUIPMENT SHALL BE DIMENSIONALLY LOCATED PER THE ARCHITECTURAL DRAWINGS. EQUIPMENT
LOCATED OTHERWISE SHALL BE RELOCATED AT THE CONTRACTOR'S EXPENSE.
CONTRACTOR SUBMITTALS
1. SUBMITTALS SHALL BE PROVIDED AS REQUIRED BY THE CONTRACTOR'S CONTRACT WITH THE OWNER, THE PROJECT SPECIFICATIONS, AND THE APPROVED CONSTRUCTION DOCUMENTS. THE SUBMITTALS REQUIRED BY THESE NOTES ARE NOT INTENDED TO BE A COMPLETE LIST OF REQUIRED SUBMITTALS.
2. WELDING: SUBMIT WELDING PROCEDURE SPECIFICATION (WPS) FOR EACH WELDING PROCEDURE TO BE USED ON THE PROJECT, AND WELDING PROCEDURE QUALIFICATION RECORD (PQR), INCLUDING TEST
RESULTS, FOR NON-PREQUALIFIED WELDING PROCEDURES. WPS AND PQR SUBMITTAL SHALL BE
REVIEWED BY THE SPECIAL INSPECTOR AND STRUCTURAL ENGINEER OF RECORD.
3. CONCRETE MIX DESIGNS: SUBMIT CONCRETE MIX DESIGN FOR EACH CONCRETE MIX TO BE USED ON THE PROJECT. THE MIX DESIGN SUBMITTAL SHALL INCLUDE THE TEST AGE FOR DEMONSTRATING COMPLIANCE WITH THE REQUIRED DESIGN STRENGTH (f'c). THE MIX DESIGN SUBMITTAL SHALL BE
REVIEWED BY THE SPECIAL INSPECTOR AND STRUCTURAL ENGINEER OF RECORD.
EQUIPMENT ANCHORAGE
1. ANCHORAGE AND SUPPORTS OF ALL EQUIPMENT TO BE INSTALLED AS A PART OF THIS PROJECT SHALL BE DETAILED ON THE CONSTRUCTION DOCUMENTS, EXCEPT THOSE EXEMPT BY 2016 CBC SECTION 1616A.1.18.
DESIGN CRITERIA
1. DESIGN BUILDING CODE 2015 INTERNATIONAL BUILDING CODE
VA H-18-8 SEISMIC DESIGN REQUIREMENTS
ASCE / SEI 7-16
2. RISK CATEGORY IV
3. FLOOR LIVE LOADS
a. OFFICE 80 PSF (REDUCIBLE)
b. INTERSTITIAL LOAD 25 PSF (REDUCIBLE)
c. CATWALKS 40 PSF
d. PARTITION ALLOWANCE 15 PSF
4. MONITOR LIVE LOAD 20 PSF (NOT REDUCIBLE)
5. WIND DESIGN CRITERIA:
a. BASIC WIND SPEED, V 115 MPH
b. WIND EXPOSURE C
c. DESIGN WIND PRESSURES FOR EXTERIOR COMPONENTS AND CLADDING DESIGNED BY OTHERS:
· ROOFTOP EQUIPMENT 38 PSF
6. SEISMIC DESIGN CRITERIA:
a. SEISMIC IMPORTANCE FACTOR, Ie 1.5
b. SPECTRAL RESPONSE PARAMETER, SS 1.276
c. SPECTRAL RESPONSE PARAMETER, S1 0.448
d. SITE CLASS D
e. DESIGN SHORT PERIOD ACCELERATION, SDS 0.85
f. SEISMIC DESIGN CATEGORY D
g. SEE "EQUIPMENT ANCHORAGE SCHEDULE" FOR COMPONENT-SPECIFIC SEISMIC DESIGN
PARAMETERS
REINFORCED CONCRETE
1. CONCRETE SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS AS INDICATED
BELOW, UNLESS OTHERWISE NOTED:
a. SLABS ON GRADE 3000 PSI
2. COMPOSITE STEEL DECK TOPPING SLABS SHALL BE LIGHTWEIGHT CONCRETE AND SHALL HAVE A
MINIMUM ULTIMATE COMPRESSIVE STRENGTH AS NOTED ABOVE.
a. WEIGHT 107 - 113 PCF
b. AIR-ENTRAINMENT 4.5% - 7.5%
3. MIX DESIGN REQUIREMENTS: SLUMP SHALL BE 4" ± 1" (A MAXIMUM SLUMP OF 8" ± 1" SHALL BE
PERMITTED AFTER INTRODUCTION OF A WATER-REDUCING ADMIXTURE FOR CONCRETE WITH A
VERIFIED MAXIMUM SLUMP OF 4" ± 1" PRIOR TO INTRODUCTION OF ADMIXTURE); MAXIMUM AGGREGATE SIZE SHALL BE 1"; MAXIMUM WATER/CEMENT RATIO SHALL BE 0.50. SEE SPECIFICATIONS FOR COMPLETE
MIX DESIGN REQUIREMENTS.
4. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND INSERTS SHALL BE WELL SECURED IN POSITION
PRIOR TO PLACING CONCRETE.
5. PROVIDE A 3/4" CHAMFER ON ALL EXPOSED CORNERS UNLESS OTHERWISE NOTED ON THE DRAWINGS.
6. ALL COLD JOINTS SHALL BE ROUGHENED AND CLEANED PRIOR TO PLACING CONCRETE.
7. CONSTRUCTION JOINTS IN CONCRETE INDICATED WITH A ROUGH, CLEAN SURFACE SHALL HAVE A 1/4"
MINIMUM AMPLITUDE.
8. CURING: CONCRETE SHALL BE MAINTAINED AT A MINIMUM TEMPERATURE OF 50 DEGREES FAHRENHEIT AND IN A MOIST CONDITION FOR AT LEAST THE FIRST SEVEN DAYS AFTER PLACEMENT. CURING SHALL
BE PERFORMED IN ACCORDANCE WITH ONE OF THE METHODS PRESCRIBED IN ACI 308R. SEE
SPECIFICATIONS FOR COMPLETE CURING REQUIREMENTS.
REINFORCING STEEL
1. STEEL BAR REINFORCING SHALL CONFORM TO ASTM A615, GRADE 60.
2. WELDING OF REINFORCING STEEL SHALL NOT BE PERMITTED.
3. BAR LAP SPLICE LENGTHS IN CONCRETE SHALL BE 48 BAR DIAMETERS UNLESS OTHERWISE NOTED ON
THE DRAWINGS.
4. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS FOLLOWS UNLESS OTHERWISE
NOTED ON THE DRAWINGS:
CONCRETE CAST AGAINST EARTH 3"
FORMED CONCRETE AGAINST EARTH 2"
CONCRETE EXPOSED TO WEATHER 2"
ALL OTHER 1 1/2"
5. ALL DETAILING, FABRICATION AND ERECTION OF REINFORCING STEEL SHALL CONFORM TO THE LATEST
EDITION OF ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT.
POST-INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS IN CONCRETE AND MASONRY, INCLUDING DRILLED-IN ANCHORS AND POWER ACTUATED FASTENERS (PAF), SHALL COMPLY WITH THE CURRENT ISSUANCE OF THE FOLLOWING
EVALUATION REPORTS, UNLESS NOTED OTHERWISE:
TYPE BASE MATL PRODUCT EVALUATION REPORT
WEDGE CONC SIMPSON STRONG BOLT 2 ICC ESR-3037
EPOXY CONC HILTI HIT-HY 200 ICC ESR-3187
2. USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING EXISTING REINFORCING STEEL, CONDUITS, AND OTHER EMBEDDED ITEMS WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWER DRIVEN
FASTENERS (PAF) IN EXISTING REINFORCED CONCRETE OR MASONRY. LOCATE EXISTING REINFORCING STEEL, CONDUITS, AND OTHER EMBEDDED ITEMS USING A NON-DESTRUCTIVE METHOD PRIOR TO DRILLING FOR ANCHORS. MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN EMBEDDED ITEMS
AND DRILLED-IN ANCHOR AND/OR PIN. LOCATED REINFORCING STEEL, CONDUITS AND OTHER
EMBEDDED ITEMS SHALL BE IDENTIFIED WITH NON-PERMANENT MARKINGS INCLUDING THE
APPROXIMATE DEPTH OF THE LOCATED ITEM, AND SHALL BE MAINTAINED IN PLACE FOR INSPECTION
UNTIL ANCHOR IS DRILLED.
3. PROVIDE INSPECTION AND TESTING FOR POST-INSTALLED ANCHORS AS REQUIRED PER THE "SPECIAL
INSPECTION AND TESTING" SECTION OF THESE GENERAL STRUCTURAL NOTES.
4. WHERE POST-INSTALLED ANCHORS ARE INSTALLED IN EXTERIOR AREAS, WET AREAS, OR EXTERIOR
WALL SILLS, ANCHORS SHALL BE STAINLESS STEEL UNLESS OTHERWISE INDICATED.
5. WHERE POST-INSTALLED ANCHORS ARE INSTALLED IN RECENTLY PLACED CONCRETE, CONCRETE SHALL ACHIEVE AT LEAST 75% OF THE SPECIFIED ULTIMATE COMPRESSIVE STRENGTH PRIOR TO DRILLING OR INSTALLING ANCHORS. CONCRETE STRENGTH SHALL BE DETERMINED IN ACCORDANCE WITH ACI 301-10, SECTION 1.6.3 OR SECTION 1.6.4, AND TEST RESULTS SHALL BE DELIVERED TO THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE PRIOR TO PROCEEDING WITH DRILLING OR ANCHOR
INSTALLATION.
STRUCTURAL STEEL
1. ANGLES, CHANNELS, PLATES, BARS AND RODS SHALL CONFORM TO ASTM A36 UNLESS OTHERWISE
NOTED ON THE DRAWINGS.
2. WIDE FLANGE SECTIONS SHALL CONFORM TO ASTM A992, GRADE 50.
3. RECTANGULAR TUBE SECTIONS (HSS) SHALL CONFORM TO ASTM A500, GRADE B.
4. PIPE SECTIONS SHALL CONFORM TO ASTM A53, GRADE B.
5. ANCHOR BOLTS SHALL BE HEADED ANCHOR BOLTS AND SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS OTHERWISE NOTED ON THE DRAWINGS.
6. BOLTS SHALL CONFORM TO ASTM A307 UNLESS OTHERWISE NOTED ON THE DRAWINGS.
7. BOLT HOLES SHALL BE 1/16" OVERSIZE UNLESS OTHERWISE NOTED ON THE DRAWINGS. BURNING OF
BOLT HOLES SHALL NOT BE PERMITTED.
8. WELDING SHALL BE PERFORMED BY AWS QUALIFIED WELDERS IN CONFORMANCE WITH AWS D1.1 USING
E70 SERIES ELECTRODES, UNLESS OTHERWISE NOTED.
9. PAINTING: ALL STEEL SHALL BE PAINTED AS INDICATED BELOW, UNLESS OTHERWISE NOTED.
GALVANIZED STEEL SHALL NOT BE PAINTED, UNLESS OTHERWISE NOTED.
a. CLEAN AND PREPARE STEEL SURFACES TO RECEIVE PAINT IN ACCORDANCE WITH THE PRIMER
MANUFACTURER'S PUBLISHED INSTRUCTIONS.
b. PRIME STEEL SURFACES WITH A ZINC-RICH PRIMER.
c. WHERE STEEL IS EXPOSED, PAINT STEEL WITH TWO FINISH COATS. COLOR SHALL BE AS NOTED;
WHERE COLOR IS NOT NOTED, MATCH COLOR OF ADJACENT FINISHED SURFACES, SUBJECT TO
OWNER'S PRIOR ACCEPTANCE.
10. GALVANIZING. STEEL EXPOSED TO WEATHER AND STEEL INDICATED AS GALVANIZED ON THE DRAWINGS
SHALL BE GALVANIZED AS FOLLOWS:
a. STEEL SECTIONS, PLATES, BARS AND RODS SHALL BE HOT-DIPPED GALVANIZED AFTER
FABRICATION IN CONFORMANCE WITH ASTM A123.
b. STEEL BOLTS, NUTS AND WASHERS SHALL BE HOT-DIPPED GALVANIZED IN CONFORMANCE WITH
ASTM A153.
c. GALVANIZED COATINGS DAMAGED BY TRANSPORTING, HANDLING, CUTTING, BOLTING OR WELDING
SHALL BE REPAIRED PER ASTM A780 USING ZINC-RICH PAINT FOR GALVANIZING.
STRUCTURAL STAINLESS STEEL
1. STAINLESS STEEL ANGLES, CHANNELS, PLATES, AND BARS SHALL CONFORM TO ASTM A276, TYPE 304 OR
316. LASER-FUSED STAINLESS STEEL SHAPES SHALL CONFORM TO ASTM A1069.
2. BOLTS AND THREADED RODS SHALL CONFORM TO ASTM A193, GRADE B8, UNLESS OTHERWISE NOTED
ON THE DRAWINGS.
3. BOLT HOLES SHALL BE 1/16" OVERSIZE UNLESS OTHERWISE NOTED ON THE DRAWINGS. BURNING OF
BOLT HOLES SHALL NOT BE PERMITTED.
4. WELDING SHALL BE PERFORMED BY AWS QUALIFIED WELDERS IN CONFORMANCE WITH AWS D1.6 USING E3XX SERIES ELECTRODES (55 KSI MIN YIELD STRENGTH AND 70 KSI MIN ULTIMATE TENSILE STRENGTH).
ELECTRODES SHALL BE SELECTED TO BE COMPATIBLE WITH MATERIALS JOINED.
5. STAINLESS STEEL FABRICATIONS SHALL BE UNCOATED UNLESS OTHERWISE INDICATED.
COLD-FORMED STEEL FRAMING
1. COLD-FORMED STEEL SECTIONS SHALL BE IN ACCORDANCE WITH ICC ESR-3064P, UNLESS OTHERWISE
INDICATED.
2. NON-STRUCTURAL SECTIONS (SUCH AS NON-BEARING PARTITION WALL FRAMING) SHALL CONFORM TO ASTM C645. MATERIALS FOR NON-STRUCTURAL SECTIONS SHALL CONFORM TO ONE OF THE FOLLOWING
STANDARDS, UNLESS OTHERWISE NOTED:
LESS THAN 16 GAGE: ASTM A653, SS GRADE 33, G40 GALV
ASTM A1003, GRADE 33 (NS33), G40 GALV
3. STRUCTURAL SECTIONS (INCLUDING ALL SECTIONS 16 GAGE AND THICKER) SHALL CONFORM TO ASTM
C955. MATERIALS FOR STRUCTURAL SECTIONS SHALL CONFORM TO ONE OF THE FOLLOWING
STANDARDS, UNLESS OTHERWISE NOTED:
LESS THAN 16 GAGE: ASTM A653, SS GRADE 33, G60 GALV
ASTM A1003, GRADE 33 TYPE H (ST33H), G60 GALV
16 GAGE AND THICKER: ASTM A653, SS GRADE 50 CLASS 1, G60 GALV
ASTM A653, HSLA GRADE 50, G60 GALV
ASTM A1003, GRADE 50 TYPE H (ST50H), G60 GALV
4. MATERIALS FOR MISCELLANEOUS PLATES AND SECTIONS SHALL CONFORM TO ONE OF THE FOLLOWING
STANDARDS:
LESS THAN 16 GAGE: ASTM A653, SS GRADE 33, G60 GALV
ASTM A1003, GRADE 33 TYPE H (ST33H), G60 GALV
16 GAGE AND THICKER: ASTM A653, SS GRADE 50 CLASS 1, G60 GALV
ASTM A653, HSLA GRADE 50, G60 GALV
ASTM A1003, GRADE 50 TYPE H (ST50H), G60 GALV
5. SCREWS FOR COLD-FORMED STEEL CONSTRUCTION SHALL CONFORM TO ONE OF THE FOLLOWING, UNLESS OTHERWISE NOTED:
ICC ESR-1976 ITW BUILDEX TEKS SELF-DRILLING
ICC ESR-2196 HILTI SELF-DRILLING AND SELF-PIERCING
ICC ESR-1408 PRO-TWIST MARKER & DARTS
ICC ESR-1271 GRABBER DRIVALL & SUPERDRIVE
6. ALL WELDING SHALL BE PERFORMED BY AWS WELDERS QUALIFIED FOR WELDING COLD-FORMED STEEL
IN CONFORMANCE WITH AWS D1.3 USING E60 ELECTRODES, UNLESS OTHERWISE NOTED.
COLD-FORMED STEEL STRUT FRAMING SYSTEM
1. ALL STRUTS AND FITTINGS SHALL BE UNISTRUT, UNLESS OTHERWISE NOTED.
2. ALL STRUTS AND FITTINGS SHALL BE INSTALLED PER MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. BOLTS INSTALLED UTILIZING CHANNEL NUTS SHALL BE TIGHTENED TO THE TORQUE PROVIDED BELOW, UNLESS OTHERWISE INDICATED IN THE MANUFACTURER'S WRITTEN INSTALLATION
INSTRUCTIONS:
BOLT DIAMETER (INCHES) TORQUE RANGE (FT-LBS)
1/4 6 - 7 5/16 11 - 15 3/8 19 - 25 1/2 50 - 70 5/8 100 - 125 3/4 125 - 135
3. ALL STRUTS AND COMPONENTS, INCLUDING ALL ASSOCIATED FITTINGS, NUTS, HARDWARE AND
FASTENERS, SHALL BE FINISHED AS FOLLOWS:
a. STRUTS AND COMPONENTS USED IN WET OR EXTERIOR APPLICATIONS SHALL BE FINISHED WITH ONE OF THE FOLLOWING FINISHES: HOT-DIPPED GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 OR A153; PERMA-GREEN III HIGH-PERFORMANCE COATING; OR PREGALVANIZED
PER ASTM A653 (G90).
b. STRUTS USED IN DRY INTERIOR APPLICATIONS SHALL BE FINISHED WITH ONE OF THE FOLLOWING FINISHES: PERMA-GREEN III HIGH-PERFORMANCE COATING; ELECTROPLATED ZINC PER ASTM B633, TYPE III SC1 OR SC3; PREGALVANIZED ZINC PER ASTM A653 (G90); OR HOT-DIPPED GALVANIZED PER
ASTM A123 OR A153. COMPONENTS MAY REMAIN UNFINISHED (PLAIN), UNLESS OTHERWISE
INDICATED.
c. GALVANIZED COATINGS DAMAGED BY TRANSPORTING, HANDLING, CUTTING, BOLTING OR WELDING
SHALL BE REPAIRED USING ASTM A780 ZINC-RICH PAINT FOR GALVANIZING.
d. HIGH-PERFORMANCE COATINGS DAMAGED BY TRANSPORTING, HANDLING, CUTTING, BOLTING OR
WELDING SHALL BE REPAIRED IN ACCORDANCE WITH THE STRUT MANUFACTURER'S PUBLISHED
REPAIR RECOMMENDATIONS.
4. PROVIDE 1/4-INCH-THICK FLAT PLATE FITTINGS BETWEEN BOLT HEAD AND STRUT AT ALL BOLTED CONNECTIONS WHERE BOLT IS INSTALLED IN OPEN FACE OF STRUT AND NO FITTING IS INDICATED ON
THE DRAWINGS.
5. PROVIDE CHANNEL NUTS AT ALL BOLTED CONNECTIONS TO OPEN FACE OF STRUT UNLESS OTHERWISE
INDICATED ON THE DRAWINGS.
6. ALL BOLTS SHALL BE 1/2" DIAMETER BOLTS CONFORMING TO ASTM A307, UNLESS OTHERWISE NOTED.
SPECIAL INSPECTION AND TESTING
SPECIAL INSPECTION AND TESTING IS REQUIRED PER CHAPTER 1701 OF THE 2015 INTERNATIONAL BUILDING CODE. REQUIRED SPECIAL INSPECTIONS AND TESTS ARE AS OUTLINED ON THIS SHEET. THE PRIME CONTRACTOR SHALL EMPLOY A SPECIAL INSPECTION OR TESTING AGENCY APPROVED BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO THE START OF WORK. COPIES OF ALL TEST AND INSPECTION REPORTS SHALL BE SUBMITTED BY THE SPECIAL INSPECTION OR TESTING AGENCY TO THE INSPECTOR OF RECORD, HOSPITAL OWNER, DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE, AND THE STRUCTURAL ENGINEER OF RECORD IN A TIMELY MANNER. REPORTS SHALL CLEARLY STATE WHETHER THE TEST OR INSPECTION
MEETS THE REQUIREMENTS OF THE APPROVED CONSTRUCTION DOCUMENTS.
1. SUPPLEMENTAL TESTING NOTES FOR POST-INSTALLED ANCHORS:
a. ONE-HALF OF BOLTS IN A GROUP SHALL BE TENSION TESTED TO THE TENSION TEST LOADS LISTED BELOW. TENSION TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE PROJECT INSPECTOR OF THE APPROVED TESTING AGENCY. IF ANY ANCHOR FAILS TESTING, ALL ANCHORS OF THE SAME TYPE SHALL BE TESTED, WHICH ARE INSTALLED BY THE SAME TRADE, NOT PREVIOIUSLY TESTED UNTIL TWENTY (20) CONSECUTIVE ANCHORS PASS, THEN RESUME THE INITIAL TEST FREQUENCY.
b. TENSION TEST LOADS:
TYPE BASE MATL DIA x EMBED (IN) LOAD (LBS) TORQUE (FT-LBS) WEDGE CONC 3/8 x VARIES N/A 30 WEDGE CONC 1/2 x VARIES N/A 60 WEDGE CONC 5/8 x VARIES N/A 90 WEDGE CONC 3/4 x VARIES N/A 150
c. ANCHOR DIAMETER IN THE ABOVE TABLE REFERS TO THE THREAD SIZE FOR WEDGE AND SHELL
ANCHORS AND TO THE OUTSIDE DIAMETER FOR SLEEVE ANCHORS.
d. APPLY PROOF LOAD TESTS TO WEDGE AND SHELL ANCHORS WITHOUT REMOVING THE NUT WHERE PRACTICABLE. WHEN THE NUT MUST BE REMOVED, INSTALL A THREADED COUPLER TO THE SAME
TORQUE AS THE REMOVED NUT USING TORQUE WRENCH, THEN APPLY TEST LOAD.
e. REACTION LOADS FROM TEST FIXTURES MAY BE APPLIED NEAR THE ANCHOR BEING TESTED
PROVIDED THE ANCHOR IS NOT RESTRAINED FROM WITHDRAWAL BY THE TEST FIXTURE.
f. TEST EQUIPMENT SHALL BE CALIBRATED BY AN APPROVED TESTING LABORATORY IN ACCORDANCE
WITH STANDARD RECOGNIZED PROCEDURES.
g. THE FOLLOWING TEST METHODS ARE ACCEPTABLE:
HYDRAULIC RAM METHOD. ANCHORS TESTED WITH A HYDRAULIC JACK OR SPRING LOADED
DEVICES SHALL MAINTAIN THE TEST LOAD FOR A MINIMUM OF 15 SECONDS AND SHALL EXHIBIT NO DISCERNABLE MOVEMENT DURING THE TENSION EST, E.G., AS EVIDENCED BY LOOSENING OF
THE WASHER UNDER THE NUT.
FOR ADHESIVE ANCHORS, WHERE OTHER THAN BOND IS BEING TESTED, THE TESTING DEVICE
SHALL NOT RESTRICT THE CONCRETE SHEAR CONE TYPE FAILURE MECHANISM FROM OCCURING.
TORQUE WRENCH METHOD. ANCHORS TESTED WITH A CALIBRATED TORQUE WRENCH MUST ATTAIN
THE SPECIFIED TORQUE WITHIN 1/2 TURN OF THE NUT.
EXCEPTIONS:
WEDGE OR SLEEVE TYPE: 1/4 TURN OF THE NUT FOR A 3/8" SLEEVE ANCHOR ONLY
THREADED TYPE: 1/4 TURN OF THE SCREW AFTER INITIAL SEATING OF THE SCREW HEAD
h. INSTALLATION OF ANCHORS SHALL COMPLY WITH THE LATEST CORRESPONDING ICC EVALUATION
REPORT.
i. IF THE MANUFACTURER'S RECOMMENDED INSTALLATION TORQUE IS LESS THAN THE VALUE LISTED IN THE ABOVE TABLE, THE MANUFACTURER'S RECOMMENDED INSTALLATION TORQUE SHALL NOT BE
EXCEEDED.
j. ALL TESTS SHALL BE PERFORMED IN THE PRESENCE OF THE OSHPD INSPECTOR OF RECORD.
k. EPOXY AND SCREW ANCHORS SHALL NOT BE TESTED USING A TORQUE WRENCH. INSTALLATION
TORQUE FOR EPOXY AND SCREW ANCHORS SHALL CONFORM TO MANUFACTURER'S WRITTEN
INSTALLATION INSTRUCTIONS.
l. SCREW ANCHORS MAY BE LOOSENED A MAXIMUM OF ONE FULL TURN TO FACILITATE THE ATTACHMENT OF A TENSION TEST COLLAR. FOLLOWING THE TENSION TEST, THE ANCHOR SHALL BE RE-TORQUED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.
m. TESTING OF ANCHORS SHALL OCCUR A MINIMUM OF 24 HOURS AFTER INSTALLATION.
SHEET INDEX
S-0.1 GENERAL STRUCTURAL NOTES 7 ABBREVIATTIONS
S-0.2 EQUIPMENT ANCHORAGE SCHEDULES
S-1.1 LEVEL 1 FLOOR PLAN - EQUIPMENT PLAN
S-1.2 LEVEL 2 INTERSTITIAL DECK - EQUIPMENT PLAN
S-1.3 LEVEL 2 ROOF PLAN - EQUIPMENT PLAN
S-5.1 STRUCTURAL DETAILS
S-5.2 STRUCTURAL DETAILS
S-5.3 STRUCTURAL DETAILS
S-5.4 STRUCTURAL DETAILS
S-5.5 STRUCTURAL DETAILS
S-6.1 STRUCTURAL DETAILS
S-6.2 STRUCTURAL DETAILS
S-6.3 STRUCTURAL DETAILS
GENERAL STRUCTURAL NOTES &
ABBREVIATIONS
EXP I RES A UGUS T 3 1 , 2
0 2
1#C 14152
STA TE
OF CA L I FORN
I A
ER
IC H . DAVY
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
08 - 6231
REVISIONS: DATE:NO.
664-18-333
BLDG #1
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLEREDFERNANDO ESTRELLA
JULY 09, 2021
PROGRAM DESIGN 20% 09/13/20191
REVIEWED IN ACCORDANCE
WITH THE REQUIREMENTS
OF CFM
BY: ____________________
DATE: ________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
SCHEMATIC DESIGN 35% 11/19/2019
MAJOR SYSTEMS 50% 12/19/2019
DESIGN DEVELOPMENT 65% 04/03/2020
CONSTRUCTION DOCUMENTS 95% 03/19/2021
CONSTRUCTION DOCUMENTS 100% 05/11/2021
IFC DOCUMENTS 07/09/2021
MODERNIZE PATHOLOGY DEPT., BLDG. 1GENERAL INFORMATION NOTES
JM / JT RA / LL
1870 Cordell Court, Suite 202 El Cajon, CA 92020 tel 619 312 6336 aarkengineering.com
R
Exp. 6/30/2022
NE
TA
S
T
FO
ACOF LI
R R
AI
L
OSOR FE SI
T I
EG
S
DE
ER
P
No. 4948
J
NA
GI
E
RE
N
EN
TS
U C
A
AR
ON
AMES STEELE
T U RAL
AS EL
S-0.2
EQUIPMENT ANCHORAGE
SCHEDULES
BLOOD BANK EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
MAX TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
BB110 HELMER BLOOD BANK FREEZER
MODEL: iPF125 551 30.8 x 32.5 x 80 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.1 FLOOR MOUNTED
BB114
HELMER BB SINGLE DOOR
REFRIGERATOR
MODEL: IB120
531 29.5 x 32.5 x
79.5 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.1 FLOOR MOUNTED
BB116 ORTHO VISION ANALYZER 419 42.3 x 30.3 x 35 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 10 / S5.1 FLOOR MOUNTED
CHEMISTRY EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
MAX TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
1 ABBOTT PROCESSING LINE 14,966 VARIES N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp
REFER TO OPM-0549 FOR
ANCHORAGE OF
EQUIPMENT PER
MANUFACTURER
RECOMMENDATION
CH103
HELMER
REFRIGERATOR (SINGLE DOOR)
MODEL: ILR125-GX
456 30 x 38 x 79 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.1
FLOOR MOUNTED, NEED
TO INCLUDE CONTENT
WEIGHT W/ CASTERS
CH104
THERMO SCIENTIFIC
FREEZER (DOUBLE DOOR)
MODEL: PRF17B
550 30 x 29 x 74 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 4 / S5.2
FLOOR MOUNTED, NEED
TO INCLUDE CONTENT
WEIGHT W/ CASTERS
CH153
HELMER
SINGLE DOOR UPRIGHT FREEZER
MODEL: ILF125
481 23.5 x 26 x 39.3 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.1 FLOOR MOUNTED
CH154
NEW BRUNSWICK
FREEZER (SINGLE DOOR)
MODEL: U725
694 44 x 39 x 77 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 3 / S5.2 FLOOR MOUNTED
POWEREX SCROLL ENCLOSED
AIR COMPRESSOR
MODEL: SED10-80-DD
1700 32 x 37.5 x 61 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 9 / S5.3 FLOOR MOUNTED
HEMATOLOGY EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
MAX TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
HE130 HELMER 2 DOOR REFRIGERATOR 702 59.25 X 32.5 X
79.5 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 6 / S5.1 FLOOR MOUNTED
M2055 WIRE STORAGE SHELVING 80 X x 18 x 74 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.4 TETHERED TO EXISTING
WALL
SPECIMEN EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
MAX TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
SP114
HELMER SINGLE DOOR
REFRIGERATOR
MODEL: ILR125
484 29.5 x 38.5 x
79.5 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.1 FLOOR MOUNTED
CYTOLOGY EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
MAX TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
CY169
SHANDON SOUTHERN INSTITUTE
LAB FUME HOOD
MODEL: 912119
70 x 30 x 84 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 3 / S5.3
CY170
MOPEC
WORK LAB PATHOLOGY
MODEL: MB600
60 x 29 x 64 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 2 / S5.3
CY187 MOPEC STORAGE 34 x 30 x 85 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.3 FLOOR MOUNTED
F0115 BOOKCASE 30 x 18 x 72 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 2 / S5.4 WALL MOUNTED
F0420 CABINET 42 x 20 x 29 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 3 / S5.4 WALL MOUNTED
HISTOLOGY EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
MAX TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
HS102
BAKER
BIOSAFETY HOOD
MODEL: STERILGUARD SG400
630 54 x 31 x 64 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 4 / S5.3 FLOOR MOUNTED
HS103
HELMER LABORATORIES
REFRIGERATOR
MODEL: 2 DOOR
702 59.25 x 32.5 x
49.5 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 6 / S5.1 FLOOR MOUNTED
HS113
KARDEX SYSTEMS
SHELVING TRAY ASSEMBLY
MODEL: SYS-115-1510-NT-US
2,716 72 x 37 x 95 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 6 / S5.2 FLOOR MOUNTED
HS115
AMERICAN BIOTECHNOLOGY
LABRATORY REFRIGERATOR
MODEL: ABT-HC-23
375 29 x 31 x 83 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.2 FLOOR MOUNTED
HS116
AMERICAN BIOTECHNOLOGY
LABRATORY FREEZER
MODEL: ABT-RFC-16A
323 30 x 35 x 78 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 2 / S5.2 FLOOR MOUNTED
MICROBIOLOGY EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
MAX TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
O2 CO2 GAS TANKS 693 12 DIA x 60 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 4 / S5.5 FLOOR MOUNTED
M0512 FLAT PANEL MONITOR 88 62 x 17 x 40 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.5
MC115
CEPHED
ANALYZER
MODEL: GENEXPERT INFINITY 80
2,100 108 x 35 x 79 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp
MC119
MC120
MC121
THERMO FISHER SCIENTIFIC
INCUBATOR
MODEL: 3950
500 38 x 33 x 80 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp
MC123
ESCO
BIOSAFETY CABINET
LB2-5B2-E
486 24.5 x 34 x 78.3 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp
MC126
BECTON DICKINSON
BLOOD CULTURE ANALYZER
BACTEC FX
486 24.5 x 34 x 78.3 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp FLOOR MOUNTED
MC136 EPPENDORF FREEZER
MODEL: U725 693 40.4 x 34.1 x
76.8 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 3 / S5.2 FLOOR MOUNTED
MC137
MC211
HELMER REFRIGERATOR
MODEL: iLR125 484 29.5 x 38.5 x
79.5 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 1 / S5.1 FLOOR MOUNTED
MC210 AUTOCLAVE
MODEL: HX-90-2D 774 35 x 45 x 56 N/A N/R 2.5 6.0 2.0 0.0 0.38 Wp 0.17 Wp 7 / S5.3 FLOOR MOUNTED
EQUIPMENT ANCHORAGE SCHEDULE GENERAL NOTES:
1. ITEMS LISTED IN THE "EQUIPMENT ANCHORAGE SCHEDULE" ARE ONLY THOSE ITEMS REQUIRING STRUCTURAL ANCHORAGE PER THE CALIFORNIA BUILDING CODE. FOR EQUIPMENT AND APPURTENANCES NOT LISTED, SEE OTHER DISCIPLINES' DRAWINGS FOR SUPPORTS AND ANCHORAGE.
2. EQUIPMENT WEIGHTS INDICATED IN THE "EQUIPMENT ANCHORAGE SCHEDULE" ARE MAXIMUM OPERATING WEIGHTS, AND INCLUDE SEISMIC WEIGHT OF CONTENTS, WHERE APPLICABLE. WEIGHTS LISTED IN THIS TABLE MAY THEREFORE DIFFER FROM THOSE SHOWN ON DRAWINGS BY OTHER DISCIPLINES.
3. Fph IS THE HORIZONTAL COMPONENT OF THE DESIGN SEISMIC FORCE, AND Fpv IS THE VERTICAL COMPONENT OF THE DESIGN SEISMIC FORCE. ALL
FORCES ARE UNFACTORED (1.0 E).
FE
C
FEC
UP
FE
C
FE
C
FE
C
FE
C
FEC
FE
C
FE
C
FEC
4 5 6
M
N
O
Q
2.1 4.2
Q.1
O.1
N.4
L.1
5.1
AREA NOT IN CONTRACT
MATCHLINE MATCHLINE
CORE LAB
(HEMATOLOGY / CHEMISTRY / SPECIMEN)
MICROBIOLOGY
HISTOLOGY
CY154
HS115
HS113
HS116
CY187
CY169
CY170
F0420
F0115
HS102
HS103
SLAB REMOVAL AND
INFILL
SLAB INFILL SLAB REMOVAL AND
INFILL
WALK-IN REFRIGERATOR WALL PANEL
(ANCHORAGE DESIGN BY OTHERS)
WALK-IN REFRIGERATOR WALL PANEL
(ANCHORAGE DESIGN BY OTHERS)
WALK-IN REFRIGERATOR
WALL PANEL (ANCHORAGE
DESIGN BY OTHERS)
F0420
F0115
CH153
O2
CO2O2
MC119
MC120
MC121
MC123
MC115
MC136
MC137
M0512
MC211
BB114
BB114
BB114
BB110
SP114
CH154
CH104
CH103
HE130
LOCKERS ANCHORAGE
PER DET 13/ S5.1
HS113
F0420
M2055
(E) 5" CONCRETE SLAB
(f'c = 2500 PSI, MIN)
CONCRETE CURB,
TYPICAL
FE
C
K
L
J.4
J.3
MATCHLINE
(E) 5" CONCRETE SLAB
(f'c = 2500 PSI, MIN)
A R C H I T E C T
EXP I RES A UGUS T 3 1 , 2
0 2
1#C 14152
STA TE
OF CA L I FORN
I A
ER
IC H . DAVY
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
08 - 6231
REVISIONS: DATE:NO.
664-18-333
BLDG #1
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLEREDFERNANDO ESTRELLA
JULY 09, 2021
PROGRAM DESIGN 20% 09/13/20191
REVIEWED IN ACCORDANCE
WITH THE REQUIREMENTS
OF CFM
BY: ____________________
DATE: ________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
SCHEMATIC DESIGN 35% 11/19/2019
MAJOR SYSTEMS 50% 12/19/2019
DESIGN DEVELOPMENT 65% 04/03/2020
CONSTRUCTION DOCUMENTS 95% 03/19/2021
CONSTRUCTION DOCUMENTS 100% 05/11/2021
IFC DOCUMENTS 07/09/2021
MODERNIZE PATHOLOGY DEPT., BLDG. 1GENERAL INFORMATION NOTES
JM / JT RA / LL
1870 Cordell Court, Suite 202 El Cajon, CA 92020 tel 619 312 6336 aarkengineering.com
R
Exp. 6/30/2022
NE
TA
S
T
FO
ACOF LI
R R
AI
L
OSOR FE SI
T I
EG
S
DE
ER
P
No. 4948
J
NA
GI
E
RE
N
EN
TS
U C
A
AR
ON
AMES STEELE
T U RAL
AS EL
LEVEL 01 EQUIPMENT PLAN A
S-1.1
S-1.1
LEVEL 01 FLOOR PLAN -
EQUIPMENT PLAN
MATCHLINE MATCHLINE
AC-101
(E) STEEL TRUSS (E) STEEL TRUSS (E) STEEL TRUSS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E) GIRDER (2GT-30)
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
MATCHLINE
EXIST 2" CONC FILL OVER 1
1/2" MTL DECK, 4 WF 13 AT
4'-0" MAX WHERE COMPOSITE
DECK OCCURS
EXIST 4WF13 STL BM (E) 4WF13 STL BM EXIST 4WF13 STL BM
EXIST 4WF13 STL BM
EXIST 4WF13 STL BM
EXIST 4WF13 STL BM
DO
DO
DO DO
DO
DO
EXIST 4I7.7 STL BM EXIST 4I7.7 STL BM EXIST 4I7.7 STL BM
EXIST 4I7.7 STL BMEXIST 4I7.7 STL BMEXIST 4I7.7 STL BM
DO DO
DO DO
DO DO
DO
DO
DO
'-8
" (F V)
9'-4" (FV)
W8X21 STL BM
W8X21 STL BM
W8X21 STL BM
EXIST STL TRUSSES
SHALL NOT BE DAMAGED
W8X21 STL BM
AC-103
1 1/2" STEEL DECK W/ 2 1/2" MIN,
REGULAR WEIGHT CONC FILL
(E) W
8x3
(E) STEEL TRUSS
(E) W8x31 BENEATH SLAB
(E) W8x31
BENEATH SLAB
W8x21 ON TOP OF SLAB, TYP OF AC UNIT FRAMING
8'-4" x 5'-4" APPROX CONC DECK
OPNG FOR AC-101-A
INSTALLATION, FRAME PER DET
5/S-6.1, INFILL PER DET 7/S-6.1
(E) W
8x3
(E) W
8x3
3'-10" x 4'-0" APPROX CONC DECK OPNG
FOR AC-103 INSTALLATION, FRAME PER
DET 5/S-6.1, INFILL PER DET 7/S-6.1
(E) STEEL TRUSS
(E) STEEL TRUSS
8'-4" x 3'-10" APPROX CONC DECK OPNG FOR AC-101-B
INSTALLATION, FRAME PER DET 5/S-6.1, INFILL PER DET 7/S-6.1
W8x21 ON TOP OF SLAB (E) STEEL TRUSS
(E) STEEL TRUSS (E) STEEL TRUSS
(E) STEEL TRUSS (E) STEEL TRUSS
AC-101-B
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x3
(E) W
8x3
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x3
(E) W
8x3
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x3
(E) W
8x3
(E) W
8x1
(E) W
8x1
(E) W
8x1 3(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x3
(E) W
8x3
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E) W
8x1
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E) W
8x1
EXIST 4WF13 STL BM
EXIST 4WF13 STL BM
DO
DO
EXIST 4I7.7 STL BM
EXIST 4I7.7 STL BM
DO
DO
DO
EXIST 4WF13 STL BM
EXIST 4WF13 STL BM
DO
DO
EXIST 4I7.7 STL BM
EXIST 4I7.7 STL BM
DO
DO
DO
EXIST 4WF13 STL BM
EXIST 4WF13 STL BM
DO
DO
EXIST 4I7.7 STL BM
EXIST 4I7.7 STL BM
DO
DO
DO
(E)
ST
EE
L T
RU
SS
EXIST 4WF13 STL BM
DO
DO
EXIST 4I7.7 STL BM
EXIST 4I7.7 STL BM
DO
DO
DO
(E) 4WF13
STL BM
GX-101
W8x10, TYP OF 2
GX-102
W8X10 STL BM
W8X10 STL BM
SOLID-TOP FIBERGLASS GRATING
WALKING PLATFORM
RH-101 HOOD OPENING ABOVE
W8x10, TYP OF 2
MATCHLINEMATCHLINE
AC-102
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E) STEEL TRUSS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E)
ST
EE
L T
RU
SS
(E) STEEL TRUSS
BUILDING
E-W AXIS
(E)
ST
EE
L T
RU
SS
EXIST 6 1/2" THK
CONC SLAB
(f'c = 3000 PSI, MIN)
EXIST 2" CONC FILL OVER MTL DECK,
4WF13 @ 4'-0" MAX WEHRE COMPOSITE DECK OCCURS
EXIST 4 I 7.7 AT 4'-0" MAX ,
TYP ALL SPANS EXCEPT UON
EXIST 4I7.7 STL BM
EXIST 4I7.7 STL BM
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
EXIST 4WF13 STL BM
EXIST 4WF13 STL BM
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
EXIST 4I7.7 STL BM
EXIST 4I7.7 STL BM
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
DO
11'-4" x 5'-6" APPROX
CONC DECK OPNG FOR
AC-102 INSTALLATION,
FRAME PER DET 5/S-6.1,
INFILL PER DET 7/S-6.1
A R C H I T E C T
EXP I RES A UGUS T 3 1 , 2
0 2
1#C 14152
STA TE
OF CA L I FORN
I A
ER
IC H . DAVY
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
08 - 6231
REVISIONS: DATE:NO.
664-18-333
BLDG #1
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLEREDFERNANDO ESTRELLA
JULY 09, 2021
PROGRAM DESIGN 20% 09/13/20191
REVIEWED IN ACCORDANCE
WITH THE REQUIREMENTS
OF CFM
BY: ____________________
DATE: ________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
SCHEMATIC DESIGN 35% 11/19/2019
MAJOR SYSTEMS 50% 12/19/2019
DESIGN DEVELOPMENT 65% 04/03/2020
CONSTRUCTION DOCUMENTS 95% 03/19/2021
CONSTRUCTION DOCUMENTS 100% 05/11/2021
IFC DOCUMENTS 07/09/2021
MODERNIZE PATHOLOGY DEPT., BLDG. 1GENERAL INFORMATION NOTES
JM / JT RA / LL
1870 Cordell Court, Suite 202 El Cajon, CA 92020 tel 619 312 6336 aarkengineering.com
R
Exp. 6/30/2022
N E
TA
S
T
FO
ACOF LI
R R
AI
L
OSOR FE SI
T I
E G
S
DE
E
R
P
No. 4948
J
NA
G
I E
R E
N E N
T S
U C
A A
R O
N
AMES STE
E L
E
T U RA
L
AS EL
LEVEL 02 INTERSTITIAL DECK - EQUIPMENT PLAN A
S-1.2
EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/hr Fph Fpv DETAIL COMMENTS
AC-101 NORTEK AIR SOLUTIONS / TEMTROL
AIR HANDLER 13329 165 x 88 x 81.5 /
112 x 88 x 81.5 N/A N/R 2.5 6.0 2.0 0.48 0.42 Wp 0.17 Wp 1 / S6.3
BASE MOUNTED ON STEEL
PLATFORM, DEFERRED
APPROVAL
AC-102 NORTEK AIR SOLUTIONS / TEMTROL
AIR HANDLER
14,171 253 x 120 x 71.5 N/A N/R 2.5 6.0 2.0 0.48 0.42 Wp 0.17 Wp 2 / S6.3
FLOOR MOUNTED ON
PLATFORM, DEFERRED
APPROVAL
AC-103 NORTEK AIR SOLUTIONS / TEMTROL
AIR HANDLER
5,976 205 x 40 x 74 N/A N/R 2.5 6.0 2.0 0.48 0.42 Wp 0.17 Wp 3 / S6.3
FLOOR MOUNTED ON
PLATFORM, DEFERRED
APPROVAL
GX-101
GREENHECK
EXHAUST FAN
MODEL: USF-24
903 42 x 57.5 x 63 N/A 0503-10 2.5 2.5 2.0 0.48 1.00 Wp 0.17 Wp 6 / S6.2 BASE MOUNTED ON
ISOLATORS
GX-102
GREENHECK
EXHAUST FAN
MODEL: QEI-30
1539 64.75 x 65 x 52.8 N/A 0502-10 2.5 2.5 2.0 0.48 1.00 Wp 0.17 Wp 8 / S6.2 BASE MOUNTED ON
ISOLATORS
VFD
ABB DRIVE
VARIABLE FREQUENCY DRIVE
MODEL: ACH 550
35 VARIES N/A 0083-10 2.5 6.0 2.0 0.48 0.42 Wp 0.17 Wp 3 / S6.3 WALL MOUNTED
EQUIPMENT ANCHORAGE SCHEDULE GENERAL NOTES:
1. ITEMS LISTED IN THE "EQUIPMENT ANCHORAGE SCHEDULE" ARE ONLY THOSE ITEMS REQUIRING STRUCTURAL ANCHORAGE PER THE CALIFORNIA BUILDING CODE. FOR EQUIPMENT AND APPURTENANCES NOT
LISTED, SEE OTHER DISCIPLINES' DRAWINGS FOR SUPPORTS AND ANCHORAGE.
2. EQUIPMENT WEIGHTS INDICATED IN THE "EQUIPMENT ANCHORAGE SCHEDULE" ARE MAXIMUM OPERATING WEIGHTS, AND INCLUDE SEISMIC WEIGHT OF CONTENTS, WHERE APPLICABLE. WEIGHTS LISTED IN THIS
TABLE MAY THEREFORE DIFFER FROM THOSE SHOWN ON DRAWINGS BY OTHER DISCIPLINES.
3. Fph IS THE HORIZONTAL COMPONENT OF THE DESIGN SEISMIC FORCE, AND Fpv IS THE VERTICAL COMPONENT OF THE DESIGN SEISMIC FORCE. ALL FORCES ARE UNFACTORED (1.0 E).
S-1.2
LEVEL 02 INTERSTITIAL DECK -
EQUIPMENT PLAN
PLAN NOTES
1. ISOLATORS AND SEISMIC RESTRAINTS FOR AIR HANDLERS AC-101, AC-102, AC-103 AND SUPPORTS AND SEISMIC RESTRAINTS ARE DELEGATED DESIGN ITEMS. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND CALCULATIONS FOR THESE ITEMS. CALCULATIONS AND SHOP DRAWINGS SHALL BE STAMPED AND SIGNED
BY A LICENSED PROFESSIONAL ENGINEER.
3 4 5 6 7
M
N
O
P
Q
2.1 3.1 3.2 4.2
Q.1
O.1
N.7
N.6
N.5
N.4
N.2
L.1
5.14.1
MATCHLINEMATCHLINE
RH-102
FX-101
FX-102
FX-105
RH-101
(E) AC-9T
(E) AC-66
(E) STEEL TRUSS
(E) STEEL TRUSS
(E) STEEL TRUSS (E) STEEL TRUSS (E) STEEL TRUSS
(E) W
(E)
W
(E) W
(E) STEEL TRUSS (E) STEEL TRUSS (E) GIRDER (2GT-30)
(E) STEEL BM (E) STEEL TRUSS
(E) STEEL TRUSS
(E) STEEL TRUSS (E) STEEL TRUSS (E) STEEL TRUSS
(E) W
(E)
W
(E) W
(E)
ST
EE
L B
M
(E) STEEL BM
(E) W
X1
(E) W12x16.5
(E) STEEL BM
(E) STEEL BM (E) STEEL BM
(E) STEEL BM
(E)
ST
EE
L B
M
(E) W
X1
(E)
DO
(E) W
X1
(E)
ST
EE
L B
M
(E)
ST
EE
L B
M (E)
ST
EE
L B M
(E)
ST
EE
L B
M
"Ø
S S
FX-104A
FX-104B
FX-106
(E) W8X10
W8X10
W8X10
(E)
DO
(E)
DO
(E) W8X10
(E) W8X10
(E) W8X10
(E) W8X10
W8X10
W8X10
W8X10
W8X10 W8X10 W8X10
FH-104A
FH-104B
W8x10
W8x10 FX-103A/B
DUCT TO BE
SUPPORTED PER
DET 4 ON SHT
S-6.2
EXIST 1 5/16" STL DECK
W/ 2 1/4" MIN LW INSULATION
CONC FILL
4'- 0"
4'- 0"
W12x14 INSTALL
BELOW DECK
W12x14 INSTALL
BELOW DECK
W12x14 INSTALL
BELOW DECK
OPENING CONNECTION PER
DET 4 ON SHT S-6.1, TYP
W12x14 INSTALL
BELOW DECK
8'-
W8X10 W8X10
W12x14 INSTALL
BELOW DECK
6'- 0"
W8X10
W8X10 W8X10
W8X10
W8X10
W8X10
(E) W12x16.5
(E) W12x16.5
(E) W12x16.5
(E) W8x10
4'-3"4'-3"
4'-3" 4'-3"
A R C H I T E C T
EXP I RES A UGUS T 3 1 , 2
0 2
1#C 14152
STA TE
OF CA L I FORN
I A
ER
IC H . DAVY
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
08 - 6231
REVISIONS: DATE:NO.
664-18-333
BLDG #1
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLEREDFERNANDO ESTRELLA
JULY 09, 2021
PROGRAM DESIGN 20% 09/13/20191
REVIEWED IN ACCORDANCE
WITH THE REQUIREMENTS
OF CFM
BY: ____________________
DATE: ________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
SCHEMATIC DESIGN 35% 11/19/2019
MAJOR SYSTEMS 50% 12/19/2019
DESIGN DEVELOPMENT 65% 04/03/2020
CONSTRUCTION DOCUMENTS 95% 03/19/2021
CONSTRUCTION DOCUMENTS 100% 05/11/2021
IFC DOCUMENTS 07/09/2021
MODERNIZE PATHOLOGY DEPT., BLDG. 1GENERAL INFORMATION NOTES
JM / JT RA / LL
1870 Cordell Court, Suite 202 El Cajon, CA 92020 tel 619 312 6336 aarkengineering.com
R
Exp. 6/30/2022
NE
TA
S
T
FO
ACOF LI
R R
AI
L
OSOR FE SI
T I
EG
S
DE
ER
P
No. 4948
J
NA
GI
E
RE
N
EN
TS
U C
A
AR
ON
AMES STEELE
T U RAL
AS EL
LEVEL 02 ROOF FRAMING EQUIPMENT PLAN A
S-1.3
EQUIPMENT ANCHORAGE SCHEDULE
MARK DESCRIPTION
TOTAL
WEIGHT
(LBS)
DIMENSIONS
W x D x H (IN) OPM OSP ap Rp Ω hx/h r Fph Fpv DETAIL COMMENTS
RH-101
GREENHECK
ROOF HOOD
MODEL: FGR
125 36 x 42 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 6 / S6.2 ROOF MOUNTED
RH-102
GREENHECK
EXHAUST FAN
MODEL:FGR
198 44 x 60 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 6 / S6.2 ROOF MOUNTED
FX-101
GREENHECK
FUME HOOD EXHAUST FAN
MODEL: VK-CD-12-4-II-LV
526 39.2 x 68.5 x
126.3 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 2 / S6.2 ROOF MOUNTED
FX-102
GREENHECK
BIOSAFETY EXHAUST FAN
MODEL: VK-MD-15-9-70-HV-HPW
1292 46.6 x 46.6 x
134.5 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 3 / S6.2 ROOF MOUNTED
FX103A/B
GREENHECK
EXHAUST FAN
MODEL: VK-MD-15-9-70-MV-HPW
2401 46.6 x 46.6 x
134.5 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 3 / S6.2 ROOF MOUNTED
FX104A/B
GREENHECK
EXHAUST FAN
MODEL: VK-CD-12-4-II-HV
1045 39.2 x 68.5 x
126.3 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 2 / S6.2 ROOF MOUNTED
FX-105
GREENHECK
EXHAUST FAN
MODEL: VK-CD-12-10-II-HV
671 46.6 x 46.6 x
134.5 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 3 / S6.2 ROOF MOUNTED
FX-106
GREENHECK
EXHAUST FAN
MODEL: VK-H-9
488 21.9 x 39.8 x 134 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 1 / S6.2 ROOF MOUNTED
FH-104A
FH-104B
AAF FLANDERS FILTER HOUSING
MODEL: BF1-1H1W 440 37 x 31 x 33 N/A N/R 2.5 6.0 2.0 1.0 0.64 Wp 0.17 Wp 4 / S6.3 ROOF MOUNTED
EQUIPMENT ANCHORAGE SCHEDULE GENERAL NOTES:
1. ITEMS LISTED IN THE "EQUIPMENT ANCHORAGE SCHEDULE" ARE ONLY THOSE ITEMS REQUIRING STRUCTURAL ANCHORAGE PER THE CALIFORNIA BUILDING CODE. FOR
EQUIPMENT AND APPURTENANCES NOT LISTED, SEE OTHER DISCIPLINES' DRAWINGS FOR SUPPORTS AND ANCHORAGE.
2. EQUIPMENT WEIGHTS INDICATED IN THE "EQUIPMENT ANCHORAGE SCHEDULE" ARE MAXIMUM OPERATING WEIGHTS, AND INCLUDE SEISMIC WEIGHT OF CONTENTS, WHERE APPLICABLE. WEIGHTS LISTED IN THIS TABLE MAY THEREFORE DIFFER FROM THOSE SHOWN ON DRAWINGS BY OTHER DISCIPLINES.
3. Fph IS THE HORIZONTAL COMPONENT OF THE DESIGN SEISMIC FORCE, AND Fpv IS THE VERTICAL COMPONENT OF THE DESIGN SEISMIC FORCE. ALL FORCES ARE UNFACTORED (1.0 E).
S-1.3
LEVEL 02 ROOF PLAN -
EQUIPMENT PLAN
" M
AX
'H'
PE
R S
CH
ED
(E) CONC SLAB-ON-GRADE
PER PLAN
EQ
EQ
SECTION A-A
EQUIP PER SCHED
FRONT REAR
EQUIP BASE
REAR SEISMIC ANCHOR
BRACKET (VFCI), TYP OF (2)
2" TY
P
.5"
M
IN
TY
P
EQ EQ
FRONT SEISMIC ANCHOR
BRACKET (VFCI), TYP OF (2)
FRONT REAR
SIDE ELEVATION
CG
CG
TYP TYP
(E) WALL (WHERE OCCURS)
" M
AX
'H'
PE
R S
CH
ED
EQUIP PER SCHED
EQ
EQ
SECTION A-A
EQUIP BASE
FRONT SEISMIC ANCHOR
BRACKET PER MFR, TYP OF (2)
REAR SEISMIC ANCHOR
BRACKET PER MFR,
TYP OF (2)
2"
MI
N
TY
P
FRONT REAR FRONT REAR
" M
IN
EQEQ
SIDE ELEVATION
(E) CONC SLAB-ON-GRADE
PER PLAN
CG
CG
TYP
TYP
(E) WALL (WHERE OCCURS)
(4) 1/4 x 1/2" SMS INTO EQUIP
FRAME EA BRACKET (VFCI)
FRONT BRACKET ASSEMBLY (VFCI)
FRONT FLOOR BRACKET
PER MFR (VFCI)
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM EMBED,
(ICC ESR-3037), TYP OF (2) EA BRACKET
EQUIP PER SCHED
NOTE:
INSTALL SEISMIC ANCHOR BRACKETS PER MANUFACTURER'S WRITTEN INSTRUCTIONS,
SEE DET 5 ON THIS SHEET
(2) 1/4" BOLTS (VFCI)
NOTE:
INSTALL SEISMIC ANCHOR BRACKETS PER MANUFACTURER'S WRITTEN INSTRUCTIONS,
SEE DET 3 ON THIS SHEET
EQUIP PER SCHED
(4) 1/4 x 1/2" SMS INTO EQUIP
FRAME, TYP EA BRACKET
REAR BRACKET
ASSEMBLY (VFCI)
SLOT PER MFR
REAR FLOOR
BRACKET (VFCI)
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM EMBED,
(ICC ESR-3037), TYP OF (2) EA BRACKET
PLAN
2"
2"
1 1/4"
2"
2 7 /8"
1 3/8"
5"
L 2 x 2 x 3/8
2"
2"
1 1/2"
4"
2"
1 3/16"
4 @ 1"
1/2 " M
IN
2 3/4"
1" 1"
PLAN
2"
2 3 /8"
1 1/8"
3/8" DIA SLOT 5"
2"
1 3/16"
3 S
PA
CE
S
1"
1 3/4"
5"
1" 1" EQ EQ
2" 1 1
/2"
3"5"
2 3/4"
PL 1/4" x 6 1/2" x 5"
L 2 x 2 x 3/8"
1" TY
P
1"
MI
N
EQUIP PER SCHED
FRONT ELEVATION
(E) CONC SLAB-ON-GRADE
PER PLAN
CG CG
CGCG
SIDE ELEVATION
SECTION A-A
FRONT
21.650"
.17
'H'
PE
R S
CH
ED
1.425"
TYP
7.3
.43 5"
.80
5"
1/2" SS THR BOLTS
PER MFR (TYP OF 4)
EQUIP OUTLINE
SECTION B-B
FRONT
21.650"1.425"
TYP2.9
.75
5" 5.8
EQUIP OUTLINE
.50
.53
CG
WT = 486#
12.25"
.40
CG
WT = 508#
12.25"
.11
MAX CG
COMBINED
.5"
M
AX
5'- 5"
SEISMIC BRACKET W/ (2) 7/16" x 4" 316 SS
CONDITION A HEX BOLTS W/ 316 SS WASHERS
ON BOTH SIDES & 316 SS LOCK WASHERS AND
NUT ON INWARD SIDE OF TUBE STL FRAME.
INSTALL BOLTS AT TOP OF SLOT & TORQUE TO
19 FT-LBS, TYP OF (2) FLOOR BRACKETS EA SIDE
OF TABLE
.5"
(2) M8x25 316 SS CONDITION A PHIL PAN HEAD
SCREW PER ASTM F593-13A, MIN FULL THREAD
ENGAGEMNET PROVIDED INSIDE UNIT, TYP,
BRACKET LOCATION PER MFR
RECOMMENDATION
2'- 6"
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM EMBED W/
WASHER, (ICC ESR-3037), TYP OF (4)
9"1"
TYP
EQ EQ
(E) 5" CONC SLAB-ON-GRADE
W/ #4 @ 18" OC EA WAY @ CENTER OF SLAB
6 7 /16
1'-
7 5 /16
4 1
/4"
4'-0"
1 11/16"
TYP
3'-8 5/8"
1'-
3/ 4"
ANALYZER PER ANCHOR
SCHED
SEISMIC BRACKET, TYP OF (4)
ORTHO VISION TABLE PER ANCHOR
SCHED
EQ
9"
EQ
44" MIN
CG
(COMBINED)
2 1 /2"
EQ
SEISMIC FLOOR BRACKET,
TYP OF (2)
ORTHO VISION TABLE PER ANCHOR
SCHED
EQ
1'- 0 1
/2"
MI
N
CL BRACKET
2'- 3"
LEVELERS
EQUIP PER SCHED
SEISMIC BRACKET W/ (2) 3/8" x 4" 316 SS
CONDITION A CARRIAGE BOLT AND NUT PER
ASTM F593-13a, MIN TORQUE TO 12 FT-LBS, THRU 3" SQ TUBE TABLE FRAME, TYP
NOTE:
FIELD VERIFY SEISMIC BRACKET LOCATIONS PER MFR
RECOMMENDATIONS 0.885"
TYP
3 SPACES @ 5.66" = 1'-5"
1.3 8"
1.50" 1.66"
2 3/4"3 1/4"
0.5 9"
45.00°
0.9 5"
0.9 5"
0.5 9"
PLAN
ELEVATION
SECTION A-A
3/8" x 0.75 HEX CAP
SCREW W/ WASHER &
LOCKWASHER SUPPLIED
BY MFR (TYP OF 4)
1 1/2" x 0.5 COUNTERSINK
(TYP OF 4)
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM
EMBED, (ICC ESR-3037), TYP OF (4)
FRONT MOUNT HEAVY
ANCHOR: HOT ROLLED STL
ASTM A36 (f'y = 36 KSI), MIN
1.29"
TYP
2.335"
TYP
3 SPACES @ 5.66" = 1'-5"
1.6 5"
TY
P
1.5 0"
TY
P
0.1
1.50" 1.66"
0.4 5"
PLAN
ELEVATION
SECTION A-A
1.0 4"
0.4 5"
2.58" TYP 19.07"
3/8" HEX CAP SCREW W/
WASHER & LOCKWASHER
SUPPLIED BY MFR (TYP OF 4)
BRACKET HEAVY ANCHOR:
8 GA HOT ROLLED STL
ASTM A569 (f'y = 38 KSI), MIN
1/2" LEVELING LEG (TYP OF 4)
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM
EMBED, (ICC ESR-3037), TYP OF (4)
A R C H I T E C T
EXP I RES A UGUS T 3 1 , 2
0 2
1#C 14152
STATE
OF CA L I FORN
I A
ER
IC H . DAVY
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
08 - 6231
REVISIONS: DATE:NO.
664-18-333
BLDG #1
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLEREDFERNANDO ESTRELLA
JULY 09, 2021
PROGRAM DESIGN 20% 09/13/20191
REVIEWED IN ACCORDANCE
WITH THE REQUIREMENTS
OF CFM
BY: ____________________
DATE: ________________
U.S. DEPARTMENT OF
VETERANS AFFAIRS
ENGINEERING SERVICES
SCHEMATIC DESIGN 35% 11/19/2019
MAJOR SYSTEMS 50% 12/19/2019
DESIGN DEVELOPMENT 65% 04/03/2020
CONSTRUCTION DOCUMENTS 95% 03/19/2021
CONSTRUCTION DOCUMENTS 100% 05/11/2021
IFC DOCUMENTS 07/09/2021
MODERNIZE PATHOLOGY DEPT., BLDG. 1GENERAL INFORMATION NOTES
JM / JT RA / LL
1870 Cordell Court, Suite 202 El Cajon, CA 92020 tel 619 312 6336 aarkengineering.com
R
Exp. 6/30/2022
NE
TA
S
T
FO
ACOF LI
R R
AI
L
OSOR FE SI
T I
EG
S
DE
ER
P
No. 4948
J
NA
GI
E
RE
N
EN
TS
U C
A
AR
ON
AMES STEELE
T U RAL
AS EL S-5.1
STRUCTURAL DETAILS
1 REFRIGERATOR ANCHORAGE DETAIL - SINGLE
1" = 1'-0"6 REFRIGERATOR ANCHORAGE DETAIL - DUAL
1" = 1'-0"
4 REFRIGERATOR ANCHORAGE DETAIL
3" = 1'-0" 2 REFRIGERATOR ANCHORAGE DETAIL
3" = 1'-0"
5 ANCHORAGE DETAIL - FRONT BRACKET
3" = 1'-0" 3 ANCHORAGE DETAIL - REAR BRACKET
3" = 1'-0"
7 ANALYZER ANCHORAGE DETAIL
3/4" = 1'-0"
10 BLOOD ANALYZER ANCHORAGE DETAIL
1" = 1'-0"
9 ANCHORAGE DETAIL - FRONT BRACKET
3" = 1'-0" 8 ANCHORAGE DETAIL - REAR BRACKET
3" = 1'-0"
CH103
CH153
MC137
MC211
SP114HS103
MC126
BB116
BB110
BB114
HE130
1/2 / 'H
'H'
PE
R S
CH
ED
FRONT ELEVATION
CG
(E) CONC SLAB-ON-GRADE
PER PLAN
EQUIP PER SCHED
SECTION A-A
CG
#12 SMS, TYP OF (3)
EA ANGLE
L4 x 2 x 3/16 (LDV), CTR ON
EQUIP, TYP OF (2), VERTICAL
LEG DIM MAY BE INCREASED UP
TO 6" (TOTAL HT) AS REQD
(E) WALL (WHERE OCCURS)
44" MAX
EQEQ
EQ
EQ
1 1
/2" MI
N
2 E Q S
PA
CE
S = 1'-
3"
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM EMBED
WASHER, (ICC ESR-3037), TYP OF (6)
3/4
MI
N
4"
MA
X
(FV
3/4
MI
N
(E) CONC SLAB-ON-GRADE
PER PLAN
2 3 /8"
NO
M
EM
BE
D
1/2" SIMPSON STRONG BOLT 2 WEDGE ANCHOR W/ 3 1/4"
NOM EMBED, TYP OF (6) TOTAL
PROVIDE 1/8" GAP (MAX) BTWN FLR & BENT PL
TO FACILITATE MOVEMENT OF EQUIP
3/16" BENT PL OR ANGLE (ASTM A36),
PAINT TO MATCH ADJACENT FINISHES
1/4" SMS, TYP OF (2) ABOVE
EA ANCHOR (8 TOTAL)
SS CAP NUT EA BOLT
2 E Q S
PA
CE
S = 1'-
3"
1/2 / 'H
'H'
PE
R S
CH
ED
SIDE ELEVATION
CG
(E) CONC SLAB-ON-GRADE
PER PLAN
EQUIP PER SCHED
SECTION A-A
CG
EQEQ
EQ
EQ
EQUIP BASE
FRONT
REAR
(E) WALL (WHERE OCCURS)
BENT PLATE OR ANGLE
TYP
NOTE:
WHERE EQUIPMENT IS LOCATED IN
CORNER OR OBSTRUCTION IS PRESENT,
PROVIDE SLOTTED HOLES IN ANGLE PER
DETAIL 7 THIS SHEET (ONE SIDE ONLY)
OMIT
SLOT
TYP
TYP
TYP
1 1
/2" MI
N
2 E Q S
PA
CE
S = 1'-
3"
1/2 / 'H
'H'
PE
R S
CH
ED
EQUIP PER SCHED
FRONT ELEVATION
(E) CONC SLAB-ON-GRADE
PER PLAN
CG
C°
F°
TYP
OMIT
SLOT
TYP
EQEQ
TYP
TYP
SECTION A-A
CG
EQ
EQ
EQUIP BASE
BENT PLATE OR ANGLE
NOTE:
WHERE EQUIPMENT IS LOCATED IN
CORNER OR OBSTRUCTION IS PRESENT,
PROVIDE SLOTTED HOLES IN ANGLE PER
DETAIL 7 THIS SHEET (ONE SIDE ONLY)
1 1
/2" MI
N
2 E Q S
PA
CE
S = 1'-
3"
1/2 / 'H
'H'
PE
R S
CH
ED
EQUIP PER SCHED
FRONT ELEVATION
(E) CONC SLAB-ON-GRADE
PER PLAN
CG TYP
OMIT
SLOT
TYP
EQEQ
TYP
TYP
SECTION A-A
CG
EQ
EQ
EQUIP BASE
BENT PLATE OR ANGLE
NOTE:
WHERE EQUIPMENT IS LOCATED IN
CORNER OR OBSTRUCTION IS PRESENT,
PROVIDE SLOTTED HOLES IN ANGLE PER
DETAIL 7 THIS SHEET (ONE SIDE ONLY)
1 1
/2" MI
N
(E) CONC SLAB-ON-GRADE
PER PLAN
PROVIDE 1/8" GAP (MAX) BTWN FLR & BENT PL
TO FACILITATE MOVEMENT OF EQUIP
PROVIDE 1/8" GAP (MAX) BTWN BOLT HEAD
& BENT PL TO FACILITATE SLIDING OF
EQUIP ONTO REAR ANCHOR BOLTS
1/2" SIMPSON STRONG BOLT 2 WEDGE ANCHOR
W/ 3 1/4" NOM EMBED, TYP OF (6) TOTAL
NOTE:
SEE DET 8 THIS SHEET FOR ITEMS SHOWN BUT NOT NOTED.
1/2
'H'
'H'
PE
R S
CH
ED
#12 SMS, TYP OF (3) EA ANGLE
L3x3x12 GA x 0'-4" LONG, TYP EA
SIDE OF EQUIP (2 TOTAL)
1"1 1 /2"
1 1/2"
MIN
(2) #12 SMS TO (E) STUD, MIN (3) STUD
(5) #12 SMS TO EQUIP
12 GA BENT PL, FV DIMS
EQUIP PER SCHED
1 1/2" MIN
TYP
EQ
EQ EQ
9 1
/2" EQ EQ
(E) CONC SLAB-ON-GRADE
PER PLAN
(E) 3 5/8" x 20 GA STUDS (MIN)
@ 16" OC
EQUIP PER SCHED
2 3 /8"
NO
M
BASE ANCHOR BRACKET
PER ELEV, TYP
6"
MA
X
CG
SIDE ELEVATION
PLAN
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM EMBED ,
(ICC ESR-3037), TYP OF (2)
1/2 / 'H
'H'
PE
R S
CH
ED
SIDE ELEVATION
CG
(E) CONC SLAB-ON-GRADE
PER PLAN
EQUIP PER SCHED
1"1 1 /2"
1 1/2"
MIN
2 3 /8"
NO
M
#12 SMS, TYP OF (3) EA ANGLE
L3x3x12 GA x 0'-4" LONG, TYP EA
SIDE OF EQUIP (2 TOTAL)
(5) #12 SMS TO EQUIP
(2) #12 SMS TO (E) STUD,
MIN (3) STUD
12 GA BENT PL, FV DIMS
PLAN
1 1/2" MIN
TYP
EQ
EQ EQ
9 1
/2" EQ EQEQ
(E) 3 5/8" x 20 GA STUDS
(MIN) @ 16" OC
EQUIP PER SCHED
BASE ANCHOR BRACKET
PER ELEV, TYP
1/2" SIMPSON STRONG BOLT 2 CONC
WEDGE ANCHOR W/ 3 1/4" NOM EMBED,
(ICC ESR-3037), TYP OF (2)
A R C H I T E C T
EXP I RES A UGUS T 3 1 , 2
0 2
1#C 14152
STATE
OF CA L I FORN
I A
ER
IC H . DAVY
OFFICE OF
CONSTRUCTION AND
FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
ENGINEER OF RECORD SHEET TITLE
F
E
D
C
B
A
VA FORM
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ARCHITECT OF RECORD
APPROVED PROJECT DIRECTOR
PROJECT PHASE
BUILDING CONSTRUCTION
PROJECT TITLE
PROJECT LOCATION
ISSUE DATE CHECK BY DRAWN BY
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
08 - 6231
REVISIONS: DATE:NO.
664-18-333
BLDG #1
3350 LA JOLLA VILLAGE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .