RFI 12 - Acoustical Ceiling.pdf
PDF 45 MB Posted
- Attached to
- 36C26125R0084 - Radiology Patient Safety
- Solicitation number
- 36C26125R0084
About this file
This document is a Request for Information (RFI) for Acoustical Ceiling Submittal related to a Department of Veterans Affairs project at the VA Medical Center Radiology Consolidation. The submittal, part of contract VA101F-14-C-0003, details specific acoustical ceiling specifications for the Palo Alto, CA facility, including multiple ceiling tile and suspension system types from manufacturers like Armstrong, USG, and Chicago Metallic.
The submittal includes detailed product data for seven different acoustical ceiling configurations (AT-1 through AT-12), with specific requirements for tile materials, grid systems, colors, and performance characteristics. Key components include Interlude XL and Suprafine XL exposed tee systems, Donin DX/DXL suspension systems, and metal panel options with specifications like Maple 650-R color and V-Perforation patterns. The document shows the submittal was reviewed and mostly approved by SJA Construction Inc., with some minor revision requests for specific grid and panel color matches.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department of Veterans Affairs
RETURN OF SUBMITTAL
Title or Description
Submittal 095100.01 RC Acoustical Ceilings Date
Contractor's Name and Address
S.J. Amoroso
390 Bridge Parkway
Redwood, CA 94063
Contract No.
VA101F-14-C-0003
Project No.
640-424-Palo Alto, CA - Phase 1 Pkng Garage, Polytrauma - Phase II Rec Therapy
Submittal Items Acted Upon Submittal Item Review Status
5215 RC Acoustical Ceiling Approved As Noted Resubmit
Product Data Notes/Comments
PROJECT NAME: ARCHITECT
VA Medical Center SmithGroup Radiology Consolidation, PS2 & LRSU
VA101F-14-C-0003
SJA Project #751
Name: Name: Amoroso Construction Co., Inc.
Address: Address: 390 Bridge Parkway Redwood City, CA 94065
Contact: Contact:
REMARKS: REVIEWER'S STAMP:
RESUBMITTAL NOT REQUIRED
MAKE CORRECTIONS NOTED (MCN) &
NOT REVIEWED. NO ACTION TAKEN (NAT)
REJECTED (REJ)
CONTENTS:
MAKE CORRECTIONS NOTED (MCN) &
RESUBMIT ONLY SPECIFIC ITEMS INDICATED (SSI)
REVISE AND RESUBMIT (RR)
DATE TO RE OFFICE:SPECIFICATION
SECTION:
SUBMITTAL TRANSMITTAL SUBMITTAL NO.
APPROVED. NO EXCEPTIONS TAKEN (NET)
SUBMITTAL REVIEW:
SUBCONTRACTOR/VENDOR: CONTRACTOR:
R09 5100.01 02 Feb, 2016
X jon gherga 02 Feb, 2016
09 51 00 1/13/2016
Spacetone Acoustics, Inc.
1051 Serpentine Lane, Suite 300 Pleasanton, CA 94566
Steve Strain Billy-Joel Celeste, Project Engineer
RADIOLOGY CONSOLIDATION
1) Manufacturer's Literature & Data per Section 1.4, C (pg. 4-35)
a) AT-1: Interlude XL 9/16" Exposed Tee System w/ Ultima#1912, 9/16" beveled tegular; 24"x24"x3/4", white tiles by Armstrong
b) AT (SP) -1: Interlude XL 9/16" Exposed Tee System w/ Ultima#1936, 9/16" beveled tegular; 24"x24"x3/4", white tiles by Armstrong
c) AT (SP) -2: Donin DX/DXL suspension system in color #004 off white (to match [E], refer to sample provided) w/Radar Basic #2110, sq. edge; 24"x24"x5/8", white tiles by USG ([E] tiles used in [E] F1-205 has been discontinued. Radar basic is its replacement)
d) AT-8: Suprafine XL 9/16" Exposed Tee System w/ Ultima#1912, 9/16" beveled tegular; 24"x24"x3/4", white tiles by Armstrong
e) AT-9: 830 All-Alum 15/16" exposed system w/Span Air Clip-In Conceal 24" sq. Metal Panel, Color: Maple 650-R, sq. edge, V-Perforation by Chicago Metallic
f) AT-10: 830 All-Alum 15/16" exposed system w/Span Air Clip-In Conceal 24" sq. Metal Panel, Color: Maple 650-R, sq. edge, V-Perforation by Chicago Metallic
g) AT-11: 1200 15/16" exposed steel HD in Grid system w/Span Air Clip-In Conceal 24" sq. Metal Panel, Color: Maple 650-R, sq. edge, V-Perforation by Chicago Metallic
h) AT-12: 1200 15/16" exposed steel HD in Grid system w/Span Air Clip-In Conceal 24" sq. Metal Panel, Color: Maple 650-R, sq. edge, V-Perforation by Chicago Metallic
2) Ceiling Suspension Installation per Section 3.2 (pg. 36-74)
3) Seismic Design Requirements per Section 1.3, A (pg. 75-108)
4) Shop drawing details and product data per Section 1.4, A (pg. 109-156)
095100.01
ACOUSTICAL CEILINGS
PROJECT NAME: ARCHITECT
VA Medical Center SmithGroup Radiology Consolidation, PS2 & LRSU
VA101F-14-C-0003
SJA Project #751
Name: Name: Amoroso Construction Co., Inc.
Address: Address: 390 Bridge Parkway Redwood City, CA 94065
Contact: Contact:
REMARKS: REVIEWER'S STAMP:
RESUBMITTAL NOT REQUIRED
MAKE CORRECTIONS NOTED (MCN) &
NOT REVIEWED. NO ACTION TAKEN (NAT)
REJECTED (REJ)
CONTENTS:
MAKE CORRECTIONS NOTED (MCN) &
RESUBMIT ONLY SPECIFIC ITEMS INDICATED (SSI)
REVISE AND RESUBMIT (RR)
DATE TO RE OFFICE:SPECIFICATION
SECTION:
SUBMITTAL TRANSMITTAL SUBMITTAL NO.
APPROVED. NO EXCEPTIONS TAKEN (NET)
SUBMITTAL REVIEW:
SUBCONTRACTOR/VENDOR: CONTRACTOR:
SEE COMMENTS ON THE FOLLOWING PAGES. RESUBMIT THE NOTTED MATERIAL/
INFORMATION FOR REVIEW AND APPROVAL.
09 51 00 1/13/2016
Spacetone Acoustics, Inc.
1051 Serpentine Lane, Suite 300 Pleasanton, CA 94566
Steve Strain Billy-Joel Celeste, Project Engineer
RADIOLOGY CONSOLIDATION
5) Samples per Section 1.4, B.1
a) Metal suspension system samples provided for AT-1, AT (SP)-1, AT (SP)-2, AT-8, AT-9, AT-10, AT-11, AT-12 as described above
b) Acoustical panel samples provided for AT-1, AT (SP)-1, AT (SP)-2, AT-8, AT-9, AT-10, AT-11, AT-12 as described above
c) Roxul Rockfon Color chip of Maple-650R for AT-9 and AT-11
d) Roxul Rockfon Color chip of Standard White-01 for AT-10 and AT-12
e) Roxul Rockfon texture chip showcasing "V" Perforation pattern for AT-10 and AT-12
f) Acoutex acoustical backer for AT-9, AT-10, AT-11, AT-12
g) Chicago Metallic 1" Encapsulated acoustic bag (polybag wrap) for AT-9, AT-10, AT-11, AT-12
Note: Colored markers for unit providing access per Section 1.4, B.2 to follow in separate submittal
ACOUSTICAL CEILINGS
APPROVED
APPROVED FOR
COLOR ONLY
APPROVED FOR
PERFORATION ONLY
APPROVED FOR COLOR ONLY.
PROVIDE PATTERN FOR AT-9
AND AT-11
APPROVED APPROVED APPROVED
APPROVED FOR
SYSTEM ONLY.
APPROVED FOR AT-10.
REVISE AND RESUBMIT FOR AT-9 (401 MAPLE
GRID TO MATCH MAPLE 650R PANEL)
APPROVED FOR AT-12.
REVISE AND RESUBMIT FOR AT-11 (401 MAPLE
GRID TO MATCH MAPLE 650R PANEL)
SJA Construction Inc.
SUBMITTAL REVIEWED
JOB NAME: VA Medical Center Radiology Consolidation PS2 &
LRSU VA101F-14-C-0003
JOB#: 751
SUBMITTAL #:
BY: BJC DATE:
1/13/16
Section 1.4, C
Profile
Edge D etail
MR EQ
Waste Recycled Regional Rapidly Low-Emitting Daylight Acoustical Reduction Content Materials Renewable Materials and Views Performance Materials
LEED Credits Recycled Content: Up to 65%
DX®
/ DXL™
15/16�15/16"
DONN DX/DXL Suspension System/ ECLIPSE Panels with CLIMAPLUS Performance
Features and Benefits
– 15/16" exposed tee system. Components for use in general and fire-rated applications
– Maximum economy and design simplicity
– DXL system features more than 80 UL designs
(up to 3 hours)
– Cross-tee override ends resist twisting and give a professionally finished look
– Meets or exceeds all national code requirements, including seismic
– Proprietary QUICK-RELEASE™ cross tees
– High recycled content (HRC) available
– Custom color available.
– ICC-ES evaluated approach to seismic design installations
(ICC-ESR-1222).
Applications
– Fire-rated, interior general use areas
Square Edge Shadowline Tapered
Shadowline Shadowline Beveled
Pedestals
Parchment 103 Manila 246 Beige 142 Straw 143 Sandstone 090 Taupe 107
Charcoal 534 Flat Black 205 Silver Satin 002 Brass 06513 Chrome 06613
Standard Colors4
White
Squash 2661 Safari 2662 Redwood 566 Sienna 565 Halo 206 Mist 053 Nectar 546 Quartz 082
Advantage Colors4
Silvertone 052 Breeze 2659 Blue Grey 564 Azure 2660 Slate 568 Spruce 567 Tuscany 2663 Sorbet 2658
Year Availability High Recycled Content
HRC
To order samples, go to usg.com
AT-SP-2
Room F1-205 match esisting
#004
Old White
See usg.com for the most up-to-date product information.
To order samples/literature:
– Web: usg.com
– E-mail: samplit@usg.com
– Fax: 888 874.2348
Technical Services: 800 USG.4YOU
Web Sites: usg.com usgdesignstudio.com sustainableceilings.com seismicceilings.com
Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661
Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment.
Read MSDS and literature before specification and installation.
DX® /DXL™
The following are trademarks of USG Interiors, LLC or a related company: AX, CLIMAPLUS, DONN, DX, DXL, ECLIPSE, QUICK-RELEASE, USG, ZXLA.
AC3167/rev. 1-12 © 2012 USG Interiors, LLC Printed in U.S.A.
L.A. Research Report Compliance DONN brand suspension systems manufactured by USG Interiors, LLC, have been reviewed and are approved by listing in one or more of the following L.A. Research Report numbers: 22179, 23451, 24095, 25764.
The City of New York BSA and MEA Report Compliance DONN suspension systems have been approved by listing in one or more of the following City of New York Board of Standards and Appeals, and Department of Building, Material and Equipment Acceptance reports:
BSA 618-60-SM, BSA 184-77-SM, BSA
796-81-SM, MEA 366-93-M,
MEA 133-95-M, MEA 312-99-M,
MEA 123-00-M.
ASTM Class Length Height Item No. Class Color Post Consumer
RC
Total RC IBC ICC-ES Evaluated Installation
4' Hanger Spacing
5' Hanger Spacing
6' Hanger Spacing 8
15/16" Tee System Main Tee Intermediate Duty
12' 1.64" DX/3, 4, 7 ,12
DXL24
Flat White Standard Advantage up to 39% up to 47%
A-C 7/8" Molding ACM7 Clip
12 lbs./LF 6.1 lbs./LF 3.6 lbs./LF
DX/3, 4, 12
DXL24 HRC
57% 65%
Heavy Duty 12' 1-1/2" DX/3, 4, 7, 12
DXL26
Flat White Standard Advantage up to 39% up to 47%
A-F 7/8" Molding ACM7 Clip
16 lbs./LF 7.3 lbs./LF 4.9 lbs./LF
DX/3, 4, 12
DXL26 HRC
57% 65%
Cross Tee
1"
2' 1" DX/3, 4, 7, 12
DXL216
Flat White Standard Advantage up to 25% up to 33%
DX/3, 4, 12
DXL216 HRC
57% 65%
Cross Tee
1-1/2"
4' 1-1/2" DX/3, 4, 7, 12
DXL424
Flat White Standard Advantage up to 20% up to 47%
DX/3, 4, 12
DXL424HRC
57% 65%
DX4225, 7, 9 Class A Flat White Standard Advantage up to 25% up to 33%
DX422HRC5 57% 65%
5' 1-1/2" DX/3, 4, 7, 12
DXL524
Flat White Standard up to 39% up to 46%
Seismic Design Categors1 Rated Load2
Wall Angle Length Item No. Color Wall Angle Length Item No Color Post Consumer RC
Total RC
Molding 10 10' M20SM-2 (up to 65% recycled content)
Flat White 12' M78 Flat White Standard Advantage up to 65%
M7 HRC8 57% 65%
Shadowline11 10' MS2745
2" shelf for seismic (Up to 65% recycled content)
Flat White Custom
10' M205
M20HD
Heavy Duty
M20SM
Seismic
Flat White Custom up to 65% up to 58% up to 65%
Product literature & samples Data sheet: AC3167. Sample flat white - seismic: 271370. Sample flat white:
215673. Sample main tee: 206563. Sample flat black: 205100.
Material Double-web G30 hot-dipped galvanized steel body and G30 hot-dipped galvanized steel cap.
Recycled content For details, see LEED report generator at usgdesignstudio.com.
Installation Must be installed in compliance with ASTM C636, ASTM E580, CISCA or standard industry practices, within all applicable code requirements. See UL Fire Resistance Directory for rated assembly details.
ASTM C635 Standard for Load Compliance System meets or exceeds load compliance specifications per ASTM C635. Main tees will not deflect more than 1/8" over 48" span (or L/360) in Light Duty, Intermediate Duty or Heavy Duty categories.
Footnotes
1. All DX/DXL main-tee and cross-tee connections meet IBC requirements for tension and compression strength.
2. Load test data shows uniform load in lbs./LF based on simple span tests in accordance with ASTM C635 deflection limit of L/360.
3. UL fire-rated listing, labeling and follow-up applies only to fire-rated components.
4. Color program for imperial only.
Consult Customer Service for custom color and metric-tee colors.
5. Non-fire-rated only.
6. Cross-tee hole punch spacings also available for 20" and 30" modules.
7. Available in metric
8. DX cross tees available in additional sizes and lengths.
9. Non-fire-rated applications may mix DX and DXL parts.
10. For moldings information, see Perimeter Interface selector.
11. Panels must be specified to be field-cut, field-revealed and to provide widest possible lay-on edge.
12. For DXL, channel moldings are also acceptable in some designs.
Check UL Fire Resistance Directory for molding options.
13. Brass and chrome available on limited items.
Limitations Severe Environmental Requirements:
Panels in exposed grids in non-fire-rated, high-humidity applications: use all-aluminum AX™ or ZXLA™ painted HDG suspension systems with aluminum cap. Panels in exposed grids in fire-rated, high-humidity applications: use ZXLA suspension systems.
For all exterior applications, suspension should be reviewed by a structural engineer.
ICC Evaluation Service, Inc., Report Compliance Suspension systems manufactured by USG Interiors, LLC, have been reviewed and are approved by listing in ICC-ESR-1222. Evaluation Reports are subject to reexamination, revision and possible cancellation. Please refer to USGDesignStudio.com or 800 USG.4YOU for current reports.
2"
2"
7/8"
3/4"11/4"
9/32"
Physical Data/ Footnotes
System meets or exceeds load compliance specifications per
ASTM C635
C O M P L I A
N T
L O A D
7/8"
7/8"
2"
1"
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
HRC
High Recycled Content Classified as containing greater than 50% total recycled content. Total recycled content is based on product composition of post-consumer and pre-consumer (post-industrial) recycled content per FTC guidelines.
HRC
Heavy Duty 12' 1-1/2" DX//3, 4, 7, 12 Flat White up to up to A-F 7/8" Molding 16 lbs./LF 7.3 lbs./LF 4.9 lbs./LF DXL26 Standard 39% 47% ACM7 Clip
Advantage
Radar™ Basic
L ig h tly
-Te x tu re d P a n e l
RADAR Basic/
DONN DX/DXL Suspension System
Features and Benefits
– Non-directional pattern with a fresh, clean appearance offers fast, efficient installation.
– Economical, all-purpose ceiling pattern offered in many sizes.
– Optional FIRECODE® product designed to meet life-safety codes.
– USDA Certified Biobased Product6.
Applications
– Schools
– Corridors
– Offices
– Retail stores
Substrate
– Wet-formed mineral fiber
Year Availability
2110, 2120, 2310, 2742
To order samples, go to usg.com
Flat White
See LEED report tool at usgdesignstudio.com for detailed sustainability information.
AT-SP-2
Room FI-205
Match existing
Manufactured by USG Interiors, LLC
550 West Adams Street
Chicago, IL 60661
Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment.
Read MSDS and literature before specification and installation.
Radar™ Basic
The following are trademarks of USG Interiors, LLC or a related company: ASPEN, CENTRICITEE, DONN, DX, DXI, DXL, DXW, FINELINE, FIRECODE, IDENTITEE, Illusion, RADAR, USG.
SC2288/rev. 12-14
© 2014 USG Interiors, LLC
Printed in U.S.A.
To order samples/literature:
Web: usg.com
E-mail: samplit@usg.com
Fax: 888 874.2348
Technical Services:
800 USG.4YOU (800 874.4968)
Websites:
usg.com usgdesignstudio.com
For the most up-to-date technical information:
usgdesignstudio.com
RADAR™ Basic SQ 2'x2'x5/8" Class A 2110 .55 33 .83 White A, B Low 24-28% $
600x600x15 ME2110
2'x2'x5/8" 2115 .55 35 .83 White A Low 41-49% $
2'x4'x5/8" Class A 2310 .55 35 .83 White A, B Low 24-28% $
600x1200x15 ME2310
2'x4'x5/8" 2315 .55 35 .83 White A Low 41-49% $
2'x5'x5/8" Class A 2619 .55 35 .83 White A, B Low 24-28% $
20"x60"x5/8" Class A 2617 .55 35 .83 White A, B Low 24-28% $
30"x60"x3/4" Class A 2618 .60 35 .83 White A, B Low 24-28% $
SLT 2'x2'x5/8" Class A 2120 .55 33 .83 White C Low 24-29% $
600x600x15 ME2120
2'x2'x5/8" 2125 .55 35 .83 White C Low 49-58%7 $
2'x4'x5/8" Class A 2320 .55 35 .83 White C Low 24-29% $
FLB 2'x2'x5/8" Class A 2130 .55 33 .83 White D, E, F, G Low 24-29% $
RADAR Basic Tile4, 5 BESK 12"x12"x5/8" Class A 2990 .505 405 .83 White H Low 44% $$$
RADAR Basic ILLUSION™ SLT 2'x4'x3/4" Class A 2742 .55 35 .83 White C Low 25-29% $$ Two/24 Panel The look of 2'x2'panels
UL Classified
Edge Panel Size Class2 Item No. NRC CAC LR3 Color Grid VOC Recycled Panel
Imperial Imperial Min. Options Emissions Content1 Cost
Metric (mm) Metric
Maximum backloading
See USG 30-Year Limited Warranty
Commercial Applications SC2102.
Maintenance
Can be cleaned easily with a soft brush or vacuum.
Notes
1. For details, see LEED report tool at usgdesignstudio.com.
2. Fire-rated items:
see UL design details.
3. LR values are shown as averages.
4. Contact USG for adhesive recommendation for 12"x12" glue-up applications.
5. Not UL Classified for acoustics.
6. This product has achieved both
BioPreferred initiatives: Federal
Procurement Preference and Certified
Product Labeling. See the complete listing of all USG ceiling panels on biopreferred.gov website.
7. Recycle content not available at all plants.
Product literature
Data sheet: SC2288
ASTM E1264 classification
Type III, Form 2, Pattern C, E and C, E, K
ASTM E84 surface burning characteristics
Class A
Flame spread: 25
Smoke developed: 50
Weight
0.61–1.15 lbs./sq. ft.
Thermal resistance
R-1.4 (Class A, 5/8" panels and tile)
R-1.7 (Class A, 3/4" panels)
R-1.4 (Class A,15 mm panels)
R-1.6 (FIRECODE, 5/8" panels)
Physical Data/ Footnotes
A
DX®/DXL™
B
DXW™
D
CENTRICITEE™
DXT™8
F
FINELINE 1/8
DXFF™
E
FINELINE®
DXF™
G
IDENTITEE™
DXI™
H
DX/DXL
Concealed
C
DX/DXL
Grid Profile Options
ILLUSION Two/24
Pattern
Legend
Low Emissions (VOC)
Low-emitting performance meets CA Specification 01350 (CA Dept. of Health
Services Standard Practice for the testing of VOC emissions) and is listed on the CHPS database for low-emitting materials. USG Certificate of Compliance for
Low VOC Emissions also available on usg.com.
HRC
> 38 CAC
FIRECODE®
> .85 LR
2'x2'x5/8" Class A 2110
Section 1.4, C.1 Section 3.2
Section 1.3, A
Section 1.4, A
Section 1.4, A
File details come from the government source that posted it. Updated .