This document is a table of contents for a specification package related to the construction of the Centers for Ambulatory Care, Polytrauma & Blind Rehabilitation Recreation Services at the VA Medical Center in Palo Alto, California.
The specification covers a wide range of construction disciplines from general requirements to various trades such as concrete, metals, wood, thermal and moisture protection, openings, finishes, specialties, equipment, furnishings, and utilities. Key sections include performance work requirements, submittals, testing, commissioning, and closeout procedures. The document also references several appendices related to the geotechnical investigation, stormwater pollution prevention plan, and an expanded room-by-room report. This specification package appears to support a federal construction solicitation, but the specific contract opportunity details are not provided in this file.
View the file
Other files for this federal contract opportunity
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Medical Center, Palo Alto, California Proj. No. 640-424 Centers for Ambulatory Care, Polytrauma & Blind Rehabilitation Recreation Services
Addendum No. 1 TOC - 1
06 SEP 2013
TABLE OF CONTENTS
VOLUME 1 0F 2
DIVISION 01 - GENERAL REQUIREMENTS
SECTION 010000 - GENERAL REQUIREMENTS (Add#01) .....................09/06/2013
SECTION 013100 - PROJECT MANAGEMENT AND COORDINATION
SECTION 013216.13 - NETWORK ANALYSIS SCHEDULES
SECTION 013323 - SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES
SECTION 014219 - REFERENCE STANDARDS
SECTION 014339.13 - VISUAL MOCKUPS
SECTION 014529 - TESTING LABORATORY SERVICES
SECTION 015719 - TEMPORARY ENVIRONMENTAL CONTROLS
SECTION 015816 - TEMPORARY INTERIOR AND EXTERIOR SIGNAGE
SECTION 016000 - PRODUCT REQUIREMENTS
SECTION 017000 - EXECUTION REQUIREMENTS
SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT
SECTION 017700 - CLOSEOUT PROCEDURES
SECTION 018111 - SUSTAINABLE DESIGN REQUIREMENTS
LEED PRODUCT DATA SUBMITTAL FORM
LEED REQUIREMENTS SCORECARD
SECTION 019100 - GENERAL COMMISSIONING REQUIREMENTS (Add#01) .......09/06/2013
DIVISION 02 - EXISTING CONDITIONS
SECTION 024100 - DEMOLITION
DIVISION 03 - CONCRETE
SECTION 030523 - COMMON WORK RESULTS FOR CAST-IN-PLACE CONCRETE SLAB
SECTION 033000 - CAST-IN-PLACE CONCRETE (Add#01) ...................09/06/2013
SECTION 033300 - ARCHITECTURAL CONCRETE
SECTION 034100 - PRECAST STRUCTURAL CONCRETE
SECTION 035200 - LIGHTWEIGHT CONCRETE ROOF INSULATION
SECTION 035416 - HYDRAULIC CEMENT UNDERLAYMENT
DIVISION 04 – MASONRY
SECTION 047210 - STONE VENEER WALL (Add#01) ........................09/06/2013
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
Addendum No. 1 TOC - 2
DIVISION 05 - METALS
SECTION 051200 - STRUCTURAL STEEL FRAMING
SECTION 051250 - ARCHITECURALLY EXPOSED STRUCTURAL STEEL
SECTION 051260 - BUCKLING RESTRAINED BRACES
SECTION 053600 - COMPOSITE METAL DECKING
SECTION 054000 - COLD-FORMED METAL FRAMING (Add#01) ................09/06/2013
SECTION 055000 - METAL FABRICATIONS
SECTION 055100 - METAL STAIRS
SECTION 057005 - LANDSCAPE METALWORK
SECTION 057500 - DECORATIVE FORMED METAL
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
SECTION 061000 - ROUGH CARPENTRY
SECTION 062000 - FINISH CARPENTRY
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
SECTION 070800 - FACILITY EXTERIOR CLOSURE COMMISSIONING
SECTION 071326 - SELF-ADHERING SHEET WATERPROOFING
SECTION 071352 - MODIFIED BITUMINOUS SHEET WATERPROOFING
SECTION 071416 - COLD FLUID-APPLIED WATERPROOFING
SECTION 071900 - WATER REPELLENTS
SECTION 072113 - THERMAL INSULATION
SECTION 072713 - MODIFIED BITUMINOUS SHEET AIR BARRIERS
SECTION 074113.16 - STANDING-SEAM METAL ROOF PANELS
SECTION 074213.16 - METAL PLATE WALL PANELS (Add#01) ...............09/06/2013
SECTION 074243.13 - FIBER-CEMENT COMPOSITE WALL PANELS
SECTION 075216.13 - STYRENE-BUTADIENE-STYRENE MODIFIED BITUMINOUS MEMBRANE
ROOFING
SECTION 075563 - VEGETATED PROTECTED MEMBRANE ROOFING (Add#01) .....09/06/2013
SECTION 076000 - FLASHING AND SHEET METAL (Add#01) .................09/06/2013
SECTION 077100 - ROOF SPECIALTIES
SECTION 078400 - FIRESTOPPING
SECTION 079200 - JOINT SEALANTS
SECTION 079513 - EXPANSION JOINT COVER ASSEMBLIES
DIVISION 08 - OPENINGS
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES
SECTION 081400 - INTERIOR WOOD DOORS
SECTION 081710 - INTEGRATED DOOR ASSEMBLIES
SECTION 083113 - ACCESS DOORS AND FRAMES
Addendum No. 1 TOC - 3
SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
SECTION 084413 - GLAZED ALUMINUM CURTAIN WALLS (Add#01) ............09/06/2013
SECTION 087100 - DOOR HARDWARE
SECTION 088000 - GLAZING
SECTION 088300 – MIRRORS
DIVISION 09 - FINISHES
SECTION 090600 - SCHEDULE FOR FINISHES (Add#01) ....................09/06/2013
SECTION 092216 - NON-STRUCTURAL METAL FRAMING
SECTION 092900 - GYPSUM BOARD
SECTION 093013 - CERAMIC/PORCELAIN TILING
SECTION 095100 - ACOUSTICAL CEILINGS
SECTION 095426 - LINEAR WOOD CEILINGS
SECTION 096340 - STONE FLOORING
SECTION 096466 - WOOD ATHLETIC FLOORING
SECTION 096513 - RESILIENT BASE AND ACCESSORIES
SECTION 096516 - RESILIENT SHEET FLOORING
SECTION 096519 - RESILIENT TILE FLOORING
SECTION 096800 - CARPETING
SECTION 097261 - SOLID SURFACE WALL CLADDING
SECTION 097500 – STONE FACING
SECTION 098433 - SOUND-ABSORBING WALL UNITS
SECTION 099100 - PAINTING
SECTION 099654 - POLYVINYLIDENE DIFLOUORIDE (PVDF) COATING SYSTEM
DIVISION 10 - SPECIALTIES
SECTION 101400 – SIGNAGE
SIGNAGE SCHEDULE
SECTION 102113 - TOILET COMPARTMENTS
SECTION 102213 - WIRE MESH PARTITIONS
SECTION 102600 - WALL AND DOOR PROTECTION
SECTION 102800 - TOILET, BATH, AND LAUNDRY ACCESSORIES
SECTION 104413 - FIRE EXTINGUISHER CABINETS
SECTION 108113 - BIRD CONTROL DEVICES
DIVISION 11 - EQUIPMENT
SECTION 112443.13 - FACADE ACCESS – SAFETY TIE-BACK ANCHOR
SECTION 116623 - GYMNASIUM EQUIPMENT
SECTION 116623.62 - BALLET BARRE
Addendum No. 1 TOC - 4
DIVISION 12 - FURNISHINGS
SECTION 122400 - WINDOW SHADES
SECTION 123600 - COUNTERTOPS
SECTION 123650 - STONE BENCHES
SECTION 124816 - ENTRANCE FLOOR GRILLES
SECTION 126613 - TELESCOPING BLEACHERS
DIVISION 13 - SPECIAL CONSTRUCTION
SECTION 130541 - SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS
DIVISION 14 - CONVEYING EQUIPMENT
SECTION 142400 - HYDRAULIC ELEVATORS
VOLUME 2 0F 2
DIVISION 21 - FIRE SUPPRESSION
SECTION 210511 - COMMON WORK RESULTS FOR FIRE SUPPRESSION
SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS
DIVISION 22 - PLUMBING
SECTION 220511 - COMMON WORK RESULTS FOR PLUMBING
SECTION 220512 - GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT
SECTION 220519 - METERS AND GAGES FOR PLUMBING PIPING
SECTION 220523 - GENERAL-DUTY VALVES FOR PLUMBING PIPING
SECTION 220711 - PLUMBING INSULATION
SECTION 221100 - FACILITY WATER DISTRIBUTION
SECTION 221123 - DOMESTIC WATER PUMPS
SECTION 221300 - FACILITY SANITARY AND VENT PIPING
SECTION 221400 - FACILITY STORM DRAINAGE (Add#01) ..................09/06/2013
SECTION 221436 - PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS
SECTION 223500 - DOMESTIC WATER HEAT EXCHANGERS
SECTION 224000 - PLUMBING FIXTURES
DIVISION 23 - HEATING, VENTILATING, AND AIR-CONDITIONING(HVAC)
SECTION 230511 - COMMON WORK RESULTS FOR HVAC
Addendum No. 1 TOC - 5
SECTION 230512 - GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION
EQUIPMENT
SECTION 230541 - NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND EQUIPMENT
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC
SECTION 230711 - HVAC AND BOILER PLANT INSULATION (Add#01) .........09/06/2013
SECTION 230923 - DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC (Add#01) ...09/06/2013
SECTION 232113 - HYDRONIC PIPING
SECTION 232123 - HYDRONIC PUMPS
SECTION 232213 - STEAM AND CONDENSATE HEATING PIPING
SECTION 232223 - STEAM CONDENSATE PUMPS
SECTION 232500 - HVAC WATER TREATMENT
SECTION 233100 - HVAC DUCTS AND CASINGS
SECTION 233400 - HVAC FANS
SECTION 233600 - TERMINAL UNITS
SECTION 233700 - OUTLETS AND INLETS
SECTION 234000 - HVAC AIR CLEANING DEVICES
SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS
SECTION 238200 - CONVECTION HEATING AND COOLING UNITS
SECTION 238216 - AIR COILS
DIVISION 26 - ELECTRICAL
SECTION 260511 - REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
SECTION 260513 - MEDIUM VOLTAGE CABLES
SECTION 260521 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 Volts and Below)
SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS
SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS
SECTION 260541 - UNDERGROUND ELECTRICAL CONSTRUCTION
SECTION 260571 - ELECTRICAL SYSTEM PROTECTIVE DEVICE STUDY
SECTION 260800 - COMMISSIONING OF ELECTRICAL SYSTEMS
SECTION 260923 - LIGHTING CONTROLS
SECTION 261219 - PAD-MOUNTED, LIQUID-FILLED, MEDIUM-VOLTAGE TRANSFORMERS
SECTION 262411 - DISTRIBUTION SWITCHBOARDS
SECTION 262416 - PANELBOARDS
SECTION 262713 - ELECTRIC METERING
SECTION 262726 - WIRING DEVICES
SECTION 262911 - MOTOR STARTERS
SECTION 262921 - DISCONNECT SWITCHES
SECTION 263005 - PHOTOVOLTAIC SYSTEMS
SECTION 263623 - AUTOMATIC TRANSFER SWITCHES
SECTION 265100 - INTERIOR LIGHTING
SECTION 265600 - EXTERIOR LIGHTING
Addendum No. 1 TOC - 6
DIVISION 27 - COMMUNICATIONS
SECTION 270511 - REQUIREMENTS FOR COMMUNICATIONS INSTALLATIONS
SECTION 270526 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS
SECTION 270533 - RACEWAYS AND BOXES FOR COMMUNICATIONS SYSTEMS
SECTION 270543 - UNDERGROUND DUCTS AND RACEWAYS FOR COMMUNICATIONS
SECTION 270811 - TESTING FOR COMMUNICATIONS
SECTION 271100 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS
SECTION 271314 - COMMUNICATIONS BACKBONE OSP TWISTED PAIR CABLING
SECTION 271324 - TELECOMMUNICATION BACKBONE OSP FIBER CABLING
SECTION 271500 - COMMUNICATIONS HORIZONTAL CABLING
SECTION 274116 - INTEGRATED AUDIOVISUAL SYSTEMS
SECTION 274131 - MASTER ANTENNA TELEVISION EQUIPMENT AND SYSTEMS
SECTION 275116 - PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
SECTION 280511 - REQUIREMENTS FOR ELECTRONIC SAFETY AND SECURITY INSTALLATIONS
SECTION 280513 - SECURITY SYSTEM CABLING
SECTION 280553 - SECURITY SYSTEM LABELING
SECTION 280800 - SECURITY SYSTEM COMMISSIONING
SECTION 281300 - ACCESS AND ALARM MONITORING SYSTEM
SECTION 283100 - DETECTION AND ALARM
DIVISION 31 - EARTHWORK
SECTION 312000 - EARTH MOVING
SECTION 312319 - DEWATERING
SECTION 312323.33 - FLOWABLE FILL
SECTION 315100 - EXCAVATION SUPPORT AND PROTECTION
DIVISION 32 - EXTERIOR IMPROVEMENTS
DELETED SECTION 320520 - CEMENT AND CONCRETE FOR LANDSCAPING EXTERIOR
IMPROVEMENTS (Add#01) ................................09/06/2013
SECTION 320523 - CEMENT AND CONCRETE FOR EXTERIOR
IMPROVEMENTS (Add#01) ................................09/06/2013
SECTION 321413 - CONCRETE PAVERS
SECTION 323113 - CHAIN LINK FENCES AND GATES
SECTION 328400 - PLANTING IRRIGATION (Add#01) ......................09/06/2013
SECTION 329000 - PLANTING (Add#01) .................................09/06/2013
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
Addendum No. 1 TOC - 7
DIVISION 33 - UTILITIES
SECTION 331000 - WATER UTILITIES
SECTION 333000 - SANITARY SEWERAGE UTILITIES (Add#01) ..............09/06/2013
SECTION 334000 - STORM DRAINAGE UTILITIES (Add#01) .................09/06/2013
SECTION 335100 - NATURAL-GAS DISTRIBUTION (Add#01) .................09/06/2013
SECTION 336300 - STEAM AND CHILLED WATER SITE DISTRIBUTION
APPENDICES
Appendix A - Geotechnical Investigation
Appendix B – Storm Water Pollution Prevention Plan
Appendix C - VA Palo Alto Expanded Room by Room Report (Add#01) ....09/06/2013
- - - E N D - - - (Add#01) 06 SEP 2013, Addendum No. 01