This document is a Table of Contents for the Architectural and Engineering (A/E) specifications for the Aquatic Therapy Center and Therapy Center project at the Department of Veterans Affairs Palo Alto Health Care System (VAPAHCS) in Palo Alto, California.
The Table of Contents outlines the various divisions and sections of the A/E specifications, including General Requirements, Concrete, Metals, Wood and Plastic, Thermal and Moisture Protection, Doors and Windows, Finishes, Specialties, Swimming Pool Construction, Fire Suppression, Plumbing, HVAC, Electrical, and Utilities. Key details include the project numbers, facility name and location, and a comprehensive listing of the technical specification sections required for this construction project.
View the file
Other files for this federal contract opportunity
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Aquatic Therapy Center and Therapy Center DVA Project Nos.
Building 530 640-370 / 640-CSI-100
VAPAHCS Palo Alto, CA
00 01 00 - 1
TABLE OF CONTENTS
Section 00 01 00
DIVISION 00 - SPECIAL SECTIONS
00 01 15 List of Drawings
DIVISION 01 - GENERAL REQUIREMENTS
01 00 00 General Requirements
01 32 16 Network Analysis
01 33 23 Shop Drawings, Product Data, and Samples
01 42 19 Reference Standards
01 45 29 Testing Laboratory Services
01 57 19 Temporary Environmental Protection
01 58 16 Temporary Interior Signs
01 74 19 Construction Waste Management
DIVISION 02 - EXISTING CONDITIONS
Not Used
DIVISION 03 - CONCRETE
03 30 00 Cast-In -Place Concrete
DIVISION 04 - MASONRY
DIVISION 05 - METALS
05 12 00 Structural Steel
05 31 00 Steel Decking
05 36 00 Composite Metal Decking
05 50 00 Metal Fabrications
05 73 13 Glazed Decorative Metal Railing
DIVISION 06 - WOOD AND PLASTIC
06 10 00 Rough Carpentry
06 40 00 Architectural Woodwork
06 61 00 Simulated Stone Fabrications
DIVISION 07 - THERMAL AND MOISTURE PROECTION
07 14 00 Fluid-Applied Waterproofing
07 21 13 Thermal Insulation
07 22 00 Roof and Deck Insulation
07 26 00 Vapor Barrier
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
00 01 00 - 2
07 26 26 Below Grade Vapor Barrier
07 27 26 Fluid-Applied Membrane Air Barrier
07 42 43 Composite Wall Panels
07 42 73 Rain Screen Panel System
07 54 23 Thermoplastic Polyolefin (TPO) Roofing
07 60 00 Flashing and Sheet Metal
07 71 00 Roof Specialties
07 81 00 Applied Fireproofing
07 84 00 Firestopping
07 92 00 Joint Sealants
DIVISION 08 - DOORS AND WINDOWS
08 11 13 Hollow Metal Doors and Frames
08 14 00 Interior Wood Doors
08 31 13 Access Doors and Frames
08 42 29 Automatic Entrances
08 44 13 Glazed Aluminum Curtain Wall
08 44 19 Fire Rated Glazed Curtain Wall
08 71 00 Door Hardware
08 71 03 Installation of Doors and Hardware
08 80 00 Glazing
08 90 00 Louvers
DIVISION 09 - FINISHES
09 06 00 Schedule for Finishes
09 22 16 Non-Structural Metal Framing
09 29 00 Gypsum Board
09 30 13 Ceramic Tiling
09 51 00 Acoustical Ceiling
09 65 13 Resilient Base and Accessories
09 65 19 Resilient Tile Flooring
09 67 23 Epoxy Coating
09 68 00 Carpeting
09 84 33 Acoustical Ceiling Paneling
09 91 00 Painting
DIVISION 10 - SPECIALTIES
10 14 00 Signage
10 21 13 Toilet Compartments
10 26 00 Wall and Door Protection
10 28 00 Toilet, Bath and Laundry Accessories
10 44 13 Fire Extinguisher Cabinets
10 51 16 Wood Lockers
10 71 23 Interior Solar Shades
DIVISION 11 - EQUIPMENT
00 01 00 - 3
DIVISION 12 - FURNISHINGS
DIVISION 13 - SPECIAL CONSTRUCTION
13 05 41 Seismic Restraint Requirements for Non-Structural Components
13 11 01 Swimming Pool Excavation
13 11 02 Swimming Pool Concrete
13 11 03 Swimming Pool Shotcrete
13 11 04 Swimming Pool Ceramic Tile
13 11 06 Swimming Pool Equipment
13 11 07 Swimming Pool Mechanical
13 11 08 Swimming Pool Electrical
DIVISION 14 - CONVEYING SYSTEMS
DIVISION 21 – FIRE SUPPRESSION
21 05 11 Common Work Results for Fire Suppression
21 10 00 Water-Based Fire-Suppression Systems
DIVISION 22 – PLUMBING
22 05 11 Common Work Results for Plumbing
22 05 12 General Motor Requirements for Plumbing Equipment
22 05 19 Meters and gages for Plumbing Piping
22 05 23 General-Duty Valves for Plumbing Piping
22 11 00 Facility Water Distribution
22 13 00 Facility Sanitary Sewerage
22 14 00 Facility Storm Drainage
22 34 00 Fuel-Fired Domestic Water Heaters
22 40 00 Plumbing Fixtures
DIVISION 23 – HEATING, VENTILATION, AND AIR CONDITIONING (HVAC)
23 05 11 Common Work Results for HVAC and Steam Generation
23 05 12 General Motor Requirements for HVAC and Steam Generation Equipment
23 05 41 Noise and Vibration Control for HVAC Piping and Equipment
23 05 93 Testing, Adjusting, and Balancing HVAC
23 07 11 HVAC, Plumbing, and Boiler Plant Insulation
23 09 23 Direct-Digital Control System for HVAC
23 11 23 Facility Natural-Gas Piping
23 21 13 Hydronic Piping
23 21 23 Hydronic Pumps
23 25 00 HVAC Water Treatment
23 31 00 HVAC Ducts and Casings
23 34 00 HVAC Fans
23 36 00 Air Terminal Units
23 37 00 Air Outlets and Inlets
23 40 00 HVAC Air Cleaning Devices
00 01 00 - 4
23 51 00 Breechings, Chimneys, and Stacks
23 52 35 Gas Fire Condensing Hot Water Boilers
23 73 00 Indoor Central-Station Air-Handling Units
23 82 16 Air Coils
DIVISION 26 - ELECTRICAL
26 05 11 Requirements for Electrical Installations
26 05 21 Low-Voltage Electrical Power Conductors and Cables (600
Volts and Below)
26 05 26 Grounding and Bonding for Electrical Systems
26 05 33 Raceway and Boxes for Electrical Construction
26 05 41 Underground Electrical Construction
26 05 71 Electrical System Protective Device Study
26 24 11 Distribution Switchboards
26 24 16 Panelboards
26 24 19 Motor-Control Centers
26 27 26 Wiring Devices
26 29 11 Low-Voltage Motor Starters
26 29 21 Disconnect Switches
26 51 00 Interior Lighting
26 56 00 Exterior Lighting
DIVISION 27 – COMMUNICATIONS
27 05 11 Requirements for Communications Installations
DIVISION 28 – ELECTRONIC SAFETY AND SECURITY
28 23 00 Video Surveillance
28 31 00 Fire Detection and Alarm
DIVISION 31 – EARTHWORK
31 20 00 Earth Moving
DIVISION 32 – EXTERIOR IMPROVEMENTS
32 05 23 Landscape Site Concrete
32 84 00 Landscape Irrigation
32 90 00 Landscape Plating and Finish Grading
32 94 00 Miscellaneous Site Furnishings
DIVISION 33 – UTILITIES
33 10 00 Water Utilities
33 30 00 Sanitary sewerage Utilities
33 40 00 Storm Drainage Utilities
33 51 00 Natural-Gas Distribution
DIVISION 34 - TRANSPORTATION
Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
VHAPALHannaC Cross-Out
00 01 00 - 5
- - - E N D - - -