About this file

This document appears to be a Request for Quotes (RFQ) for the Department of Veterans Affairs to obtain a contractor to develop a Maintenance Management Plan. The RFQ provides details on the required services, including developing a maintenance management plan, defining maintenance roles and responsibilities, and documenting maintenance procedures. The RFQ references a solicitation number (36C26124Q0843) and an opportunity ID (Z1DZ--Develop Maintenance Management Plan(VA-24-00017482)). The work is to be performed at the VA Medical Center in Palo Alto, California. No pricing terms, set asides, incumbent contractors, or award dates are provided in the RFQ.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DZ--Develop Maintenance Management Plan Solicitation Amendment | Change of Site Visit, Response date and add attachments, newest first.
File Type Posted
P01 - PWS Attachment 14 - Quality Assurance Surveillance Plan.pdf PDF
36C26124Q0843 0001.docx DOCX document
P01 - PWS Attachment 6b - Building 500 Drawings - Part 02.pdf PDF
P01 - PWS Attachment 6d - Building 500 Drawings - Part 04.pdf PDF
P01 - PWS Attachment 6e - Building 500 Drawings - Part 05.pdf PDF
P01 - PWS Attachment 9a - Building 710 Drawings - Vol 01.pdf PDF
P01 - PWS Attachment 16a - Building 530 Scope.pdf PDF
P01 - PWS Attachment 2 - Building 500 Scope.pdf PDF
P01 - PWS Attachment 4 - Building 710 Scope.pdf PDF
P01 - PWS Attachment 6c - Building 500 Drawings - Part 03.pdf PDF
P01 - PWS Attachment 8 - Building 615 Drawings.pdf PDF
P01 - PWS Attachment 3 - Buildings 603 and 615 Scope.pdf PDF
P01 - PWS Attachment 5a - Building 100 G-wing Drawings - Part 01.pdf PDF
P01 - PWS Attachment 5b - Building 100 G-wing Drawings - Part 02.pdf PDF
P01 - PWS Attachment 6a - Building 500 Drawings - Part 01.pdf PDF
P01 - PWS Attachment 7 - Building 603 Drawings.pdf PDF
P01 - PWS Attachment 9b - Building 710 Drawings - Vol 02.pdf PDF
P01 - PWS Attachment 16b - Building 530 Scope.pdf PDF
36C26124Q0843 DEVELOP MAINTENANCE MANAGEMENT PLAN.pdf PDF
36C26124Q0843_3.docx DOCX document
Past Performance Surveys.docx DOCX document
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA Medical Center, Palo Alto, California Proj. No. 640-424 Loop Road and Site Utilities, Radiology Consolidation, Parking Structure 2

ADDENDUM NO. 04 TOC - 1

28 OCT 2013

TABLE OF CONTENTS

VOLUME 1: DIVISION 01 - GENERAL REQUIREMENTS

VOLUME 2: LOOP ROAD AND SITE UTILITIES

VOLUME 3: LOOP ROAD AND SITE UTILITIES (CONTINUED)

VOLUME 4: RADIOLOGY CONSOLIDATION

VOLUME 5: RADIOLOGY CONSOLIDATION (CONTINUED)

VOLUME 6: PARKING STRUCTURE 2

VOLUME 7 APPENDICES

VOLUME 1 OF 7 DIVISION 01 – GENERAL REQUIREMENTS

DIVISION 01 - GENERAL REQUIREMENTS

SECTION 010000 - GENERAL REQUIREMENTS (Add#02) ......................10/07/2013

SECTION 013100 - PROJECT MANAGEMENT AND COORDINATION

SECTION 013216.13 - NETWORK ANALYSIS SCHEDULES

SECTION 013323 - SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

SECTION 014219 - REFERENCE STANDARDS

SECTION 015719 - TEMPORARY ENVIRONMENTAL CONTROLS

SECTION 015816 - TEMPORARY INTERIOR SIGNAGE

SECTION 016000 - PRODUCT REQUIREMENTS

SECTION 017000 - EXECUTION REQUIREMENTS

SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT

SECTION 017700 - CLOSEOUT PROCEDURES

VOLUME 4 OF 7 RADIOLOGY CONSOLIDATION

DIVISION 00 - SPECIAL SECTIONS

SECTION 000115.02 - LIST OF DRAWING SHEETS

- RADIOLOGY CONSOLIDATION (Add#01) (Add#04) .............10/28/2013

DIVISION 01 - GENERAL REQUIREMENTS

SECTION 014339.13 - VISUAL MOCKUPS (Add#01) ........................09/18/2013

SECTION 014529.02 - TESTING LABORATORY SERVICES - RADIOLOGY CONSOLIDATION

SECTION 018111.02 - SUSTAINABLE DESIGN REQUIREMENTS - RADIOLOGY

CONSOLIDATION (Add#01)................................09/18/2013

LEED PRODUCT DATA SUBMITTAL FORM

LEED REQUIREMENTS SCORECARD

SECTION 019100.02 - GENERAL COMMISSIONING REQUIREMENTS – RADIOLOGY

CONSOLIDATION

VHAPALHannaC Cross-Out

VHAPALHannaC Cross-Out

VHAPALHannaC Cross-Out

VHAPALHannaC Cross-Out

VHAPALHannaC Cross-Out

VHAPALHannaC Cross-Out

ADDENDUM NO. 04 TOC - 2

DIVISION 02 - EXISTING CONDITIONS

SECTION 024100 – DEMOLITION (Add#01) ...............................09/18/2013

SECTION 024119 - SELECTIVE STRUCTURE DEMOLITION (Add#01) ............09/18/2013

SECTION 028213.13 - GLOVEBAG ASBESTOS ABATEMENT (Add#01) ............09/18/2013

SECTION 028213.31 - ASBESTOS TRANSITE ABATEMENT

DIVISION 03 - CONCRETE

SECTION 033000 - CAST-IN-PLACE CONCRETE (Add#01) ...................09/18/2013

SECTION 033300 - ARCHITECTURAL CONCRETE

SECTION 034100 - PRECAST STRUCTURAL CONCRETE FOR STEAM TRENCHES AND

VAULTS (Add#01) ......................................09/18/2013

SECTION 035200 - LIGHTWEIGHT INSULATING CONCRETE

DIVISION 04 - MASONRY

SECTION 042513.13 - TERRACOTTA RAINSCREEN PANELS (Add#01) ..........09/18/2013

SECTION 047210 - STONE VENEER WALL (Add#01) ........................09/18/2013

DIVISION 05 - METALS

SECTION 051200 - STRUCTURAL STEEL FRAMING (Add#01) .................09/18/2013

SECTION 051250 - ARCHITECTURALLY EXPOSED STRUCTURAL STEEL

SECTION 053100 - STEEL DECKING

SECTION 053600 - COMPOSITE METAL DECKING

SECTION 054000 - COLD-FORMED METAL FRAMING

SECTION 055000 - METAL FABRICATIONS (Add#01) ........................09/18/2013

SECTION 055100 - METAL STAIRS

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

SECTION 061000 - ROUGH CARPENTRY

SECTION 062000 - FINISH CARPENTRY

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

SECTION 070800 - FACILITY EXTERIOR CLOSURE COMMISSIONING

SECTION 071326 - SELF-ADHERING SHEET WATERPROOFING

SECTION 071352 - MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION 071416 - COLD FLUID-APPLIED WATERPROOFING

SECTION 072113 - THERMAL INSULATION (Add#01) .......................09/18/2013

SECTION 072613.13 - CONCRETE SLAB APPLIED VAPOR RETARDER

VHAPALHannaC Cross-Out

ADDENDUM NO. 04 TOC - 3

SECTION 072713 - MODIFIED BITUMINOUS SHEET AIR BARRIERS (Add#01) ....09/18/2013

SECTION 074113.16 - STANDING-SEAM METAL ROOF PANELS

SECTION 074213.13 - FORMED METAL WALL PANELS

SECTION 074213.16 - METAL PLATE WALL PANELS (Add#01) ................09/18/2013

SECTION 075216.13 - STYRENE-BUTADIENE-STYRENE MODIFIED BITUMINOUS MEMBRANE

ROOFING, COLD-APPLIED (Add#01)........................09/18/2013

SECTION 076000 - FLASHING AND SHEET METAL

SECTION 077100 - ROOF SPECIALTIES

SECTION 078100 - APPLIED FIREPROOFING

SECTION 078400 - FIRESTOPPING

SECTION 079200 - JOINT SEALANTS

SECTION 079513 - EXPANSION JOINT COVER ASSEMBLIES

DIVISION 08 - OPENINGS

SECTION 081113 - HOLLOW METAL DOORS AND FRAMES (Add#01) ............09/18/2013

SECTION 081400 - INTERIOR WOOD DOORS (Add#01) .......................09/18/2013

SECTION 081710 - INTEGRATED DOOR ASSEMBLIES (Add#01) ................09/18/2013

SECTION 083113 - ACCESS DOORS AND FRAMES

SECTION 083473 - SOUND CONTROL DOOR ASSEMBLIES

SECTION 083513.23 - ACCORDION FOLDING FIRE DOORS (Add#01) ...........09/18/2013

SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION 084413 - GLAZED ALUMINUM CURTAIN WALLS (Add#01) .............09/18/2013

SECTION 086300 - METAL-FRAMED SKYLIGHTS

SECTION 087100 - DOOR HARDWARE (Add#01) ............................09/18/2013

SECTION 087113 - AUTOMATIC DOOR OPERATORS (Add#01) ..................09/18/2013

SECTION 087113.11 - LOW ENERGY POWER ASSIST DOOR

OPERATORS (Add#01) ...................................09/18/2013

SECTION 088000 - GLAZING (Add#01) ...................................09/18/2013

DIVISION 09 - FINISHES

SECTION 090600 - SCHEDULE FOR FINISHES (Add#01) ....................09/18/2013

SECTION 092216 - NON-STRUCTURAL METAL FRAMING (Add#01) .............09/18/2013

SECTION 092400 - PORTLAND CEMENT PLASTERING

SECTION 092900 - GYPSUM BOARD

SECTION 093013 - CERAMIC/PORCELAIN TILING (Add#01) .................09/18/2013

SECTION 095100 - ACOUSTICAL CEILINGS (Add#01) ......................09/18/2013

SECTION 095426 - LINEAR WOOD CEILINGS (Add#01) .....................09/18/2013

SECTION 095429 - WOOD PANEL CEILINGS

SECTION 096513 - RESILIENT BASE AND ACCESSORIES (Add#01) ............09/18/2013

SECTION 096516 - RESILIENT SHEET FLOORING

SECTION 096516.13 - LINOLEUM FLOORING

SECTION 096519 - RESILIENT TILE FLOORING

SECTION 096536 - STATIC-CONTROL RESILIENT FLOORING (Add#01) ........09/18/2013

ADDENDUM NO. 04 TOC - 4

SECTION 096800 - CARPETING (Add#01) ................................09/18/2013

SECTION 098433 - SOUND-ABSORBING WALL UNITS

SECTION 099100 - PAINTING (Add#01) .................................09/18/2013

SECTION 099600 - HIGH-PERFORMANCE COATINGS

SECTION 099654 - POLYVINYLIDENE DIFLUORIDE (PVDF)

COATING SYSTEM (Add#01) ..............................09/18/2013

SECTION 099659 - HIGH-BUILD GLAZED COATINGS (Add#01) ...............09/18/2013

DIVISION 10 - SPECIALTIES

SECTION 101400 - SIGNAGE

SIGNAGE SCHEDULE (Add#01) ........................................09/18/2013

SECTION 102113 - TOILET COMPARTMENTS (Add#01) ......................09/18/2013

SECTION 102123 - CUBICLE CURTAIN TRACKS

SECTION 102600 - WALL AND DOOR PROTECTION (Add#01) ..................09/18/2013

SECTION 102800 - TOILET, BATH, AND LAUNDRY ACCESSORIES

SECTION 104413 - FIRE EXTINGUISHER CABINETS

SECTION 105116 - WOOD LOCKERS

SECTION 108113 - BIRD CONTROL DEVICES

DIVISION 11 - EQUIPMENT

SECTION 11 23 43 - HANGING GARMENT CONVEYORS (Add#01) ..............09/18/2013

SECTION 112443.13 - WINDOW WASHING SYSTEMS SAFETY TIE-BACK ANCHOR

SECTION 117000 - HEALTHCARE EQUIPMENT

DIVISION 12 - FURNISHINGS

SECTION 122400 - WINDOW SHADES (Add#01) ............................09/18/2013

SECTION 123200 - MANUFACTURED WOOD CASEWORK

SECTION 123600 - COUNTERTOPS

SECTION 124813 - ENTRANCE FLOOR MATS (Add#01) ......................09/18/2013

DIVISION 13 - SPECIAL CONSTRUCTION

SECTION 130541 - SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL

COMPONENTS (Add#01)...................................09/18/2013

SECTION 134900 - RADIATION PROTECTION (Add#01) ......................09/18/2013

WEST PHYSICS CONSULTING SHIELDING DESIGN LETTER

SECTION 134927 - MAGNETIC RESONANCE IMAGING (MRI) SHIELDED

ENCLOSURES (Add#01) (Add#02) .............................10/07/2013

ADDENDUM NO. 04 TOC - 5

VOLUME 5 OF 7 RADIOLOGY CONSOLIDATION (CONTINUED)

DIVISION 21 - FIRE SUPPRESSION

SECTION 210512 - MOTOR REQUIREMENTS FOR FIRE-SUPPRESSION

EQUIPMENT (Add#01) ..................................09/18/2013

SECTION 210511 - COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS (Add#01) ................09/18/2013

SECTION 213000 - FIRE PUMPS (Add#01) ...............................09/18/2013

DIVISION 22 - PLUMBING

SECTION 220511 - COMMON WORK RESULTS FOR PLUMBING (Add#01) .........09/18/2013

SECTION 220512 - GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

SECTION 220523 - GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION 220711 - PLUMBING INSULATION

SECTION 221100 - FACILITY WATER DISTRIBUTION

SECTION 221300 - FACILITY SANITARY AND VENT PIPING (Add#01) ........09/18/2013

SECTION 221400 - FACILITY STORM DRAINAGE (Add#01) ..................09/18/2013

SECTION 221436 - PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

SECTION 224000 - PLUMBING FIXTURES (Add#01) ........................09/18/2013

SECTION 226200 - VACUUM SYSTEMS FOR LABORATORY AND HEALTHCARE FACILITIES

SECTION 226300 - GAS SYSTEMS FOR LABORATORY AND HEALTHCARE FACILITIES

DIVISION 23 - HEATING, VENTILATING, AND AIR-CONDITIONING (HVAC)

SECTION 230130.51 - HVAC AIR-DISTRIBUTION SYSTEM CLEANING

SECTION 230511 - COMMON WORK RESULTS FOR HVAC (Add#01) .............09/18/2013

SECTION 230512 - GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION

EQUIPMENT

SECTION 230541 - NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND EQUIPMENT

SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC

SECTION 230711 - HVAC AND BOILER PLANT INSULATION (Add#01) .........09/18/2013

SECTION 230923 - DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC (Add#01) ...09/18/2013

SECTION 232113 - HYDRONIC PIPING (Add#01) ..........................09/18/2013

SECTION 232123 - HYDRONIC PUMPS

SECTION 232213 - STEAM AND CONDENSATE HEATING PIPING

SECTION 232223 - STEAM CONDENSATE PUMPS

SECTION 232300 - REFRIGERANT PIPING

SECTION 232500 - HVAC WATER TREATMENT

SECTION 233100 - HVAC DUCTS AND CASINGS (Add#01) ...................09/18/2013

SECTION 233400 - HVAC FANS

SECTION 233600 - TERMINAL UNITS

SECTION 233700 - OUTLETS AND INLETS

ADDENDUM NO. 04 TOC - 6

SECTION 234000 - HVAC AIR CLEANING DEVICES

SECTION 236400 - PACKAGED WATER CHILLERS (Add#01) ..................09/18/2013

SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION

AIR-HANDLING UNITS (Add#01) ..........................09/18/2013

SECTION 238100 - DECENTRALIZED UNITARY HVAC EQUIPMENT

SECTION 238200 - CONVECTION HEATING AND COOLING UNITS

SECTION 238216 - AIR COILS

DIVISION 26 - ELECTRICAL

SECTION 260511 - REQUIREMENTS FOR ELECTRICAL INSTALLATIONS

SECTION 260521 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS

AND BELOW)

SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS (Add#01) ..09/18/2013

SECTION 260536 - WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION 260541 - UNDERGROUND ELECTRICAL CONSTRUCTION

SECTION 260571 - ELECTRICAL SYSTEM PROTECTIVE DEVICE STUDY

SECTION 260800 - COMMISSIONING OF ELECTRICAL SYSTEMS

SECTION 260923 - LIGHTING CONTROLS

SECTION 262200 - LOW-VOLTAGE TRANSFORMERS

SECTION 262411 - DISTRIBUTION SWITCHBOARDS

SECTION 262416 - PANELBOARDS

SECTION 262419 - MOTOR-CONTROL CENTERS

SECTION 262511 - BUSWAYS

SECTION 262713 - ELECTRIC METERING

SECTION 262726 - WIRING DEVICES

SECTION 262911 - MOTOR STARTERS

SECTION 262921 - DISCONNECT SWITCHES

SECTION 263005 - PHOTOVOLTAIC SYSTEMS

SECTION 264200 - CATHODIC PROTECTION (Add#01) .......................09/18/2013

SECTION 265100 - INTERIOR LIGHTING

SECTION 265600 - EXTERIOR LIGHTING

DIVISION 27 - COMMUNICATIONS

SECTION 270511 - REQUIREMENTS FOR COMMUNICATIONS INSTALLATIONS

SECTION 270526 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS

SECTION 270533 - RACEWAYS AND BOXES FOR COMMUNICATIONS SYSTEMS

SECTION 270543 - UNDERGROUND DUCTS AND RACEWAYS FOR COMMUNICATIONS

SECTION 270811 - TESTING FOR COMMUNICATIONS

SECTION 271100 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS (Add#01) ...09/18/2013

SECTION 271313 - TELECOMMUNICATION BACKBONE TWISTED PAIR CABLING

SECTION 271323 - TELECOMMUNICATION BACKBONE ISP FIBER CABLING

SECTION 271500 - COMMUNICATIONS HORIZONTAL CABLING (Add#01) ........09/18/2013

ADDENDUM NO. 04 TOC - 7

SECTION 274116 - INTEGRATED AUDIOVISUAL SYSTEMS

SECTION 274131 - MASTER ANTENNA TELEVISION EQUIPMENT AND SYSTEMS

SECTION 275116 - PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

SECTION 275123 - INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

SECTION 275223 - TELECOMMUNICATION NURSE CALL SYSTEMS

DIVISION 28 - ELECTRONIC SAFETY AND SECURITY

SECTION 280000 - BASIC SECURITY REQUIREMENTS (Add#01) ...............09/18/2013

SECTION 280513 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION 280553 - SECURITY SYSTEM LABELING

SECTION 280800 - SECURITY SYSTEM ACCEPTANCE TESTING

SECTION 281300 - ACCESS AND ALARM MONITORING SYSTEM (Add#01) ........09/18/2013

SECTION 283100 - DETECTION AND ALARM

DIVISION 31 - EARTHWORK

SECTION 312000 - EARTH MOVING

SECTION 312319 - DEWATERING

SECTION 312323.33 - FLOWABLE FILL

SECTION 315100 - EXCAVATION SUPPORT AND PROTECTION

DIVISION 32 - EXTERIOR IMPROVEMENTS

SECTION 320523 - CEMENT AND CONCRETE FOR EXTERIOR

IMPROVEMENTS (Add#01) (Add#02) ...........................10/07/2013

SECTION 321216 - ASPHALT PAVING

SECTION 321413 - TURF BLOCK PAVERS (Add#01) .........................09/18/2013

SECTION 321723 - PAVEMENT MARKINGS

SECTION 328400 - PLANTING IRRIGATION (Add#01) ......................09/18/2013

SECTION 329000 - PLANTING (Add#01) (Add#02) ............................10/07/2013

SECTION 329453 - TREE SOIL CELLS (Add#01) ..........................09/18/2013

DIVISION 33 - UTILITIES

SECTION 331000 - WATER UTILITIES

SECTION 333000 - SANITARY SEWERAGE UTILITIES (Add#01) ..............09/18/2013

SECTION 334000 - STORM DRAINAGE UTILITIES (Add#01) (Add#04) ............10/28/2013

SECTION 334716.17 - BIORETENTION AREA, SWALE, AND PERMEABLE PAVEMENT DRAINAGE

SECTION 336300 - STEAM AND CHILLED WATER SITE

DISTRIBUTION (Add#01) ................................09/18/2013

DIVISION 34 - TRANSPORTATION

SECTION 347513.13 - ACTIVE VEHICLE BARRIERS

Cross-Out

VHAPALHannaC Cross-Out

VHAPALHannaC Cross-Out

VHAPALHannaC Cross-Out

ADDENDUM NO. 04 TOC - 8

VOLUME 7 OF 7 APPENDICES

Appendix A - Geotechnical Investigation: Phase 2 Improvements – Packages 1, 2, 3, and 5

Appendix B - Facilities Protection Plan for Hillview-Porter Regional Program Groundwater Remediation Facilities at the Veterans Administration Hospital Property, Palo Alto, Ca.

Appendix C - Stormwater Pollution Prevention Plan

- - - E N D - - -

(Add#01) 18 SEP 2013, Addendum No. 1 (Add#02) 07 OCT 2013, Addendum No. 2 (Add#04) 28 OCT 2013, Addendum No. 4