About this file

This document includes an overall site plan drawing and details for improving site access and physical security deficiencies at a Veterans Affairs Medical Center. The drawing depicts the medical center campus layout and calls for installing various new and replacement perimeter fencing, gates, bollards and barriers throughout the site. These security upgrades include constructing an anti-ram wall barrier at the main entrance, installing motorized and manual vehicular gates, erecting semi-permanent and permanent fencing, positioning emergency call posts with cameras, and emplacing anti-ram bollards. The related federal contract opportunity solicitation seeks bids for Project 570-19-107 to implement the security improvements shown on the drawing in accordance with the specifications. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 21 office.

View the file

Other files for this federal contract opportunity

Other files attached to Project 570-19-107 | Improve Site Access and Physical Security Deficiencies, newest first.
File Type Posted
SF30- Clarification on Due Date.pdf PDF
SF30- Amend 0003.pdf PDF
Site Visit Attendance Roster.pdf PDF
RFI Atch 2- AS 101.pdf PDF
36C26123R0110 Amend 0002.pdf PDF
36C26123R0110 RFIs.pdf PDF
RFI Atch 1 Soils Report.pdf PDF
SF30 Amend 0001- Clarify Site Visit Date.pdf PDF
Request for Information(RFI) Form.docx DOCX document
Supplemental Price Breakdown.xlsx XLSX spreadsheet
04_Architectural Drawings (1).pdf PDF
05_Structural Drawings (1).pdf PDF
06_MEP Drawings (1).pdf PDF
02_Civil Drawings (1).pdf PDF
APPENDIX B.pdf PDF
Large Business Subcontracting Plan Template.docx DOCX document
CONTRACTOR CERTIFICATION REGARDING SAFETY AND ENVIRONMENTAL.docx DOCX document
001.RFP 36C26123R0110 Improve Site Access and Security Deficiencies.pdf PDF
CA Wage Determination 20230018 - 09292023.pdf PDF
VA Specifications- Final.pdf PDF
01_General Drawings (1).pdf PDF
03_Landscape Drawings (1).pdf PDF
07_FP Topo and Misc Drawings (1).pdf PDF
Appendix A Revised 10-6-23.pdf PDF
APPENDIX C.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUS

B U S

BUS

EL 308.5

EL 308.5

MAIN

ENTRANCE

SIGN

V A

M O N U M E N T

S

IG

N

M O N U M E N T

S

IG

N

S P E E D

B U M P

MAIN

B-19 B-19A

GENERATOR

B-5

PUMPHOUSE

STAGING

AREA

G E N E R A T O R

G E N E R A T O R

G E N E R A T O R

G E N E R A T O R

G E N E R A T O R

SWITCHGEARSWITCHGEAR

U T

IL

IT

Y

V A U L T

FUEL TANK

#2

FUEL TANK

#1

TANK

O2

TANK

O2

TANK

DIESEL

TANK

DIESEL

B-8

STORAGE

SHEDS

B-7

GASOLINE

PUMP &

TANKS

B-4

PUMPHOUSE

B-17 LIQUID

OXYGEN STORAGE

CANOPY

O P C

A N C

IL

L A R Y

S H E L T E R

S M O K

IN

G

H Y D R O N

IC

S

U T

IL

IT

Y

P A D

B-24

TOILETS

T-5

ENGR. TRAILER

B-18

ELEVATOR

SOLAR PANELS

SOLAR PANELS

S P E E D

B U M P

B-31

COMMUNITY

B-1

MAIN

B-3

ENGINEERING

B-2

BOILER PLANT

WAREHOUSE

B-32

OUTPATIENT

OPC

MENTAL

B-25

B-34

MENTAL HEALTH

HEALTH

FREEDOM

CLINIC

HOSPITAL B-24

LIBERTY

BLDG

LIVING

CENTER

VALOR BLDG

BLDG

B-27

MENTAL HEALTH

INDEPENDENCE BLDG

B-36

BARN

B-24

AUDITORIUM

B-24 BREEZEWAY

B-22

CHILLER

B-22A

CHILLER

W A

L K

O F

H O

N O

R

MODULAR 2

LOT C

BBQ

PARKING LOT A

PARKING LOT B

P A

R K

IN

G

L O

T C

PARKING LOT E

P A

R K

IN

G

L O

T F

PARKING LOT G

PARKING LOT D

CLC

BUILDING

P A

R K

IN

G

L O

T H

MOTORCYCLES

YIELD

YIELD

1 5 4

LOADING DOCK

GENERATOR YARD

OXYGEN STORAGE

AE-101

AS-102

AS-103

AS-107

AS-104

AS-109

AS-108

AS-106

15' - 3" 128' - 7" 48' - 4"

BUS STOP

49' - 6" 76' - 2"

AS-105

AS-110

AS-110

G01

M01

M02

M05

M04

M03

G05

E. CLINTON AVENUE

E

F R

E S

N O

S T

R E

E T

E. HARVARD AVENUE

N

A N

G U

S S

T R

E E

T

G08 G09

G02

AS-105 1

AS-104 4

AS-105

AS-105

AS-105

56' - 1" 32' - 1"64' - 1"

17' - 8"

24' - 0" 112' - 0" 31' - 2"

B U

S S

T O

P

18' - 4" 91' - 10" 45' - 11" 30' - 7"

AS-104

109' - 7" 172' - 5" 125' - 4"

16' - 6" 33' - 0"

68' - 0"

135°

G04

407' - 4"

8' - 0"

192' - 2"

4' - 6"

16' - 0"

4' - 6"

8' - 0"8' - 0"

TYP.

8' - 0"

G03

6' - 3"7' - 1" 112' - 0" 7' - 4" 49' - 7"

106' - 1"

EQ EQ 3

EQ EQ

8' - 0"

12' - 0"

EQ

EQ

E Q

E Q6' - 0"

EQ EQ

E Q

E Q

EQ EQ

LEGEND:

FENCE TYPE 1: NEW PERMANENT FENCE - BRICK

AND STEEL

FENCE TYPE 2: NEW SEMI-PERMANENT FENCE -

STEEL

FENCE TYPE 3: NEW ANTI-RAM BARRIER

FENCE TYPE 4: LOW CONCRETE PLANTER WALL

W/ SEMI-PERMANENT FENCE

NEW PERMANENT VEHICULAR ROLLING METAL

GATE NO TRACK, OVERHANG PER PSDM

NEW MOTORIZED BARRIER UPSWING ARM GATE

NEW PERMANENT METAL VEHICULAR SWING

GATE (MANUAL OR MOTORIZED PER VA)

NEW SEMI-PERMANENT VEHICULAR METAL SWING

GATE

NEW METAL SWING MAN GATE

NEW EMERGENCY CALL POST

NEW ANTI-RAM BOLLARDS TYPE-A

NEW BOLLARDS TYPE-B

GATE TAG, SEE SCHED. ON SHEET AS-106G01

Location

Issue Date

VA FORM 08 - 6231

A

F ile

P a th

BID SET RE-SUBMITTAL

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

570-19-107

03-17-2023

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT IMPROVE SITE ACCESS AND

PHYSICAL SECURITY

DEFICIENCIES

VAMC, FRESNO, CA, 93703

Project Director

Revisions: Date: Dwg. of

35% SCHEMATIC DESIGN

65% DESIGN DEVELOPMENT

315 ARDEN AVE, SUITE #23,

t: 888.900.3823 www.schwabeng.com

GLENDALE, CA 91203

PROJECT NO.: S60204180.00

11/12/2021

06/07/2021

95% CONSTRUCTION DOCUMENT 07/18/2022

100% CONSTRUCTION DOCUMENT 10/03/2022

BID SET SUBMITTAL 10/31/2022

BID SET RE-SUBMITTAL 03/17/2023

E RITA KALWANI

F

C

EXP. 3-31-2023

No. C 14658

A T

O E

R

AT

S

R

T EH I NROF

CA L I

TC I A

E T

C

O

SI

T

G

R

E R

DE

P AN

OE SSF I

A

RC

L

H

TI

AS-101

RK JA

OVERALL SITE PLAN

1" = 40'-0"1

OVERALL SITE PLAN

N

40'20' 80'0 40'20' 80'0

DEMONEW

KEY NOTES - ENLARGED SITE PLAN

1 CHAIN LINK SWING GATE

2 (E) LOW CMU WALL TO REMAIN

3 (E) METAL FENCE AND GATE TO REMAIN

4 (E) METAL PANEL WALL TO REMAIN

5 CMU LOW PLANTER WALL 3'-0" MIN ABOVE GRADE WITH 5' PICKET FENCE

TYPE 4

6 (E) CHAIN LINK SWING GATES TO REMAIN

7 BOLLARDS TYPE-B, SEE SHEET 1/AS-109 FOR SPACING

8 (E) 10' HIGH CMU WALL ENCLOSURE TO REMAIN

9 SEMI-PERMANENT VEHICULAR SWING GATE

10 (E) CHAIN LINK FENCE FOR CONSTRUCTION STAGING

11 NOT USED

12 (E) PAINTED ALUMINUM FENCE TO REMAIN

13 ANTI-RAM WALL BARRIER TYPE 3, SEE STRUCTURAL FOR MORE INFO.

14 MAN GATE MANUAL WITH KEY LOCK OPTION AND PANIC DEVICE

15 SEMI-PERMANENT FENCE TYPE 2, SEE DETAILS 2,3,4/AS-103 & 1,2/AS-105

16 PERMANENT FENCE TYPE 1, SEE DETAILS 2,3,4,5/AS-102, 3,4/AS-104, &

3,4/AS-105

17 EMERGENCY CALL POST/CAMERA, SEE STRUCTURAL DETAIL 12 ON SHEET

S101 FOR TYP. FOOTINGS

18 ANTI-RAM BOLLARDS TYPE-A, SEE PLAN FOR SPACING

19 PERMANENT VEHICULAR SWING GATE

20 PERMANENT VEHICULAR ROLLING GATE

21 MOTORIZED BARRIER UP-SWING GATE

22 REMODEL/ EXPAND RELOCATE SECURITY MONITOR ROOM, SEE SHEET

AE-101

GENERAL NOTES:

1. VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE

CONDITIONS BEFORE STARTING WORK. NOTIFY THE CO

IMMEDIATELY OF ANY DISCREPANCIES.

2. SEE ALL DISCIPLINE DRAWINGS FOR FULL SCOPE OF

WORK.

3. SEE FINISH SCHEDULE ON AF-101 FOR FINISHES.

4. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR

NOTED FOR ANY PART OF THE WORK, SUCH DETAILS

SHALL BE THE SAME AS FOR SIMILAR WORK SHOWN ON

THE DRAWINGS.

5. LOCATE AND PROTECT UNDERGROUND UTILITIES.

6. FOR GATE SCHEDULE, REFER TO SHEET AS-601.