This document package includes structural drawings and details for a federal construction project to improve site access and physical security deficiencies at a Department of Veterans Affairs medical center. The project includes installing new security fencing, anti-ram barriers, bollards, and gates at the site perimeter and building entrances. The structural drawings provide specifications for concrete mix designs and reinforcing, foundation details for fencing and barriers, and connections between posts, piers and walls. Bollards and anti-ram barriers must be tested to stop a 4000-pound vehicle at 30 mph with minimal penetration. The solicitation number is 36C26123R0110 and seeks offers for Project 570-19-107 under the Veterans Health Administration Veterans Integrated Service Network 21.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONCRETE
LIGHTWEIGHT AGGREGATES (CONFORMING TO ASTM C330) SHALL BE
APPROVED BY THE ENGINEER, AND THEIR MAXIMUM SIZE SHALL BE 1 INCH.
HARDROCK AGGREGATES SHALL CONFORM TO ASTM C33. THEIR MAXIMUM SIZE
SHALL BE 1-1/2 INCHES FOR FOOTINGS AND GRADE BEAMS AND 1 INCH FOR ALL
OTHER WORK.
CEMENT SHALL CONFORM TO ASTM C150 TYPE I OR II.
CONCRETE SHALL BE AS FOLLOWS:
CONTINUOUS INSPECTION IS REQUIRED FOR ALL CONCRETE WITH A DESIGN
STRENGTH OVER 2000 PSI.
ONLY ONE GRADE OF CONCRETE SHALL BE POURED ON THE JOB AT ONE TIME.
A STATEMENT OF MIX DESIGN SHALL BE MADE FOR CONCRETE WITH DESIGN
STRENGTH OVER 2500 PSI. COPIES OF THE MIX DESIGN SHALL BE SUBMITTED TO
THE CONTRACTING OFFICER REPRESENTATIVE FOR APPROVAL BEFORE USE.
NOTE: A HIGHER GRADE OF CONCRETE MAY BE SUBSTITUTED FOR THOSE SHOWN
ABOVE, BUT WILL BE SUBJECT TO THE CODE REQUIREMENTS OF THE HIGHER GRADE.
ALL REINFORCING SHOWN CONTINUOUS SHALL BE LAPPED PER ACI 318 CLASS B
SPLICE OR 40 DIAMETERS (GRADE 60) AT SPLICES, AND SHALL BE MADE AWAY
FROM POINTS OF MAXIMUM STRESS. MINIMUM LAP SHALL BE 2'-0" LONG.
FORMS FOR CONCRETE STRUCTURAL MEMBERS (SLABS, BEAMS, ETC.) SHALL NOT
BE STRIPPED UNTIL THE CONCRETE HAS REACHED ITS DESIGNED STRENGTH.
ALL CONCRETE IS DESIGNED BY ULTIMATE STRENGTH DESIGN METHOD.
A MIX THAT PRODUCES THE LOWEST SLUMP COMPATIBLE WITH PROPER
PLACEMENT SHALL BE USED (4-1/2" MAXIMUM SLUMP UNLESS OTHERWISE
APPROVED BY THE STRUCTURAL ENGINEER.)
CONCRETE GROUT SHALL BE NON SHRINKING WITH SUFFICIENT WATER TO
ALLOW POURING. ULTIMATE COMPRESSIVE STRENGTH (F'C) AT 28 DAYS SHALL
BE EQUAL TO 3000 PSI MINIMUM.
DRY PACK CONCRETE SHALL BE ONE PART PORTLAND CEMENT AND ONE PART
SAND WITH SUFFICIENT WATER TO ALLOW A SMALL AMOUNT OF PASTE TO
COME TO THE SURFACE.
ALL SLEEVES NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE LOCATED
BY THE TRADES INVOLVED AND SHALL BE APPROVED BY THE ENGINEER.
BEFORE CONCRETE IS POURED, CHECK WITH ALL TRADES TO INSURE PROPER
PLACEMENT OF ALL OPENINGS, SLEEVES, CURBS, CONDUITS, BOLTS, INSERTS,
ETC. RELATING TO WORK.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
2. TIES AND STIRRUPS
1. MAIN BARS IN BEAMS AND COLUMNS
C. NOT EXPOSED TO EARTH OR WEATHER
1. CAST-IN-PLACE - NON STRESSED
1-1/2" 2"
2"
3"A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH
CONCRETE COVER OVER REINFORCING SHALL BE AS FOLLOWS:
B. EXPOSED TO EARTH OR WEATHER
FOOTINGS HARDROCK 4000 PSI 145 PCF
AGGREGATES STRENGTH
@ 28 DAYS
DRY
WEIGHT
LOCATION
GENERAL NOTES
ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO SPECIFICATIONS,
PLANS AND ALL GOVERNING ORDINANCES.
ALL WORKS SHALL COMPLY WITH INTERNATIONAL BUILDING CODE (IBC) 2021, VA
H-18-8 SEISMIC DESIGN REQUIREMENTS
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE
JOB PRIOR TO STARTING CONSTRUCTION AND THE CONTRACTING OFFICER
REPRESENTATIVE SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES OR
INCONSISTENCIES. DO NOT SCALE DIMENSIONS, WHERE NO DIMENSIONS ARE
PROVIDED, CONSULT WITH CONTRACTING OFFICER REPRESENTATIVE FOR
CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS OR
AND CODE REQUIREMENTS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS
OWN EXPENSE AND AT NO EXPENSE TO THE GOVERNMENT.
ALL SYMBOLS AND ABBREVIATIONS USED IN THE DRAWINGS ARE CONSIDERED
TO BE CONSTRUCTION STANDARDS. IF CLARIFICATIONS ARE REQUIRED, THE
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER PRIOR TO
PROCEEDING WITH THE WORK.
NO OPENINGS, POCKETS, NOTCHES, BLOCK-OUTS, ETC. ARE ALLOWED IN
STRUCTURAL ELEMENTS UNLESS DETAILED ON THE STRUCTURAL DRAWINGS.
NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE OF ANY OPENINGS,
POCKETS, ETC. SHOWN BY OTHER DRAWINGS BUT NOT SHOWN ON THE
STRUCTURAL DRAWINGS.
THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT
THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES INCLUDE BUT NOT
LIMITED TO BRACING, SHORING, ETC. OBSERVATION VISITS TO THE SITE BY THE
CONTRACTING OFFICER, ARCHITECT, OR ENGINEER SHALL NOT INCLUDE THE
INSPECTION OF BRACING, SHORING, ETC.
CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IF PLACED ON FRAMED
FLOORS, ROOF, ETC. THE LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD OF
20 PSF (POUNDS PER SQUARE FOOT) UNLESS APROVED OTHERWISE BY
ENGINEER OF RECORD.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATION PROCEDURES
INCLUDING LAGGING, SHORING, AND PROTECTION OF ADJACENT PROPERTY,
STRUCTURES, STREET, AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL,
STATE AND LOCAL SAFETY ORDINANCES.
SEE MECHANICAL, ELECTRICAL AND/OR ARCHITECTURAL DRAWINGS FOR
LOCATION AND SIZE OF PIPE, VENT, DUCT, OTHER SIMILAR OPENINGS, AND
EMBEDDED OR ATTACHED ITEMS.
NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL
NOTES AND TYPICAL DETAILS.
DO NOT SCALE DRAWINGS.12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC
FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF
SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF
RESPONSIBILITY TO THE CONTRACTING OFFICER PRIOR TO THE
COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER IBC 2021
SEC 1704.4
13.
1. SPECIAL INSPECTION PER IBC 2018 CHAPTER 17 BY A PERSON WHOSE QUALIFICATIONS ARE ACCEPTABLE TO THE STRUCTURAL ENGINEER OF RECORD AND SHALL BE REQUIRED FOR THE FOLLOWING WORK:
A. CONCRETE STRENGTH GREATER THAN 2500 psi
B. POST INSTALLED ANCHORS WEDGE AND EPOXY ANCHORS.
C. HIGH STRENGTH BOLTS
D. SHOP AND FIELD WELDING
2. INSPECTION REPORTS SHALL BE PROVIDED TO THE CONTRACTING OFFICER REPRESENTATIVE WITHIN A WEEK OF INSPECTION.
3. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO DEMONSTRATES COMPETENCE TO THE SATISFACTION OF THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR THE DESIGN OF THE
THE STRUCTURE FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR
OPERATION REQUIRING SPECIAL INSPECTION.
4. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR:
THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH:
A. THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE INSPECTOR SHALL NOT ALTER, MODIFY, ENLARGE, OR WAIVE ANY OF THE REQUIREMENTS OF THE DOCUMENTS.
B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE CONTRACTING OFFICER REPRESENTATIVE ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTIONS, THEN IF UNCORRECTED SUBMIT A COMPLETE LIST OF ALL OUTSTANDING DISCREPANCIES ON A WEEKLY BASIS TO THE
CONTRACTING OFFICER REPRESENTATIVE UNTIL ALL CORRECTIONS HAVE BEEN COMPLETED.
C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK
REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE INSPECTOR'S KNOWLEDGE, IN
CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE
WORKMANSHIP PROVISIONS OF THE BUILDING CODE.
5. WHERE SPECIAL INSPECTION REQUIREMENTS DUPLICATE THE REQUIREMENTS OF OTHER SPECIFIED
TESTING, DUPLICATE INSPECTIONS SHALL NOT BE REQUIRED
SPECIAL INSPECTION PER 2021 IBC
SEISMIC DESIGN DATA:
SEISMIC IMPORTANCE FACTOR
MAPPED SPECTRAL RESPONSE: S 1
SPECTRAL RESPONSE: DS D1
SEISMIC DESIGN CATEGORY: D
I = 1.5 S = 0.507 S = 0.223 S =0.472 S = 0.290
1.
RISK CATEGORY: IV ESSENTIAL FACILITY
SITE CLASS: D
DESIGN CRITERIA
D. ELEVATED SLAB 1"
CONCRETE MIX. DESIGN SHALL CONTAIN AIR ENTRAINMENT PRODUCT. MINIMUM
ENTRAINED CONTENT SHALL BE 5%.
17.
1. METAL STUDS SHALL BE BY CEMCO (ICC ESR-3016) OR APPROVED EQUAL.
2. STUDS SHALL BE GALVANIZED.
3. STUD FRAMING SHALL BE IN ACCORDANCE WITH AISI 2016 EDITION, "NORTH AMERICAN
SPECIFICATIONS FOR DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS".
5. WALL STUDS AND TRACKS SHALL CONFORM TO ASTM A1003, TYPE H AND GRADE AS INDICATED.
6. STUDS SHALL CONFORM TO ASTM GRADE 50. TRACKS SHALL CONFORM TO ASTM , GRADE 50.
METAL STUD WALLS SHOWN ON PLANS SHALL BE AS FOLLOWS:
METAL STUDS
EFFECTIVE PROPERTIES (U.N.O. ON PLANS)
6"
1 5 8"
16 2.316 0.767 GA Ix Sx GRADE
50 Ksi
16 2.641 0.717 GA Ix Sx GRADE
50 KsiTRACK
2"
14 13.665 2.42 GA Ix Sx GRADE
50 Ksi
6"
2"
CONCRETE WALLS HARDROCK 4000 PSI 145 PCF
POST INSTALLED ANCHORS
1. TESTING OF ANCHORS SHALL BE AS PER IBC 2018
2. ALL FIELD INSTALLED CONCRETE EXPANSION ANCHORS SHALL BE
APPROVED FOR THE TYPE AND INSTALLATION, FOR ITS APPLICATION, AND
MATERIALS. EXPANSION ANCHORS SHALL BE HILTI KWIK BOLT TZ (
ICC-ESR-1917) HILTI - HSL 3 (ICC-ESR-1545) OR APPROVED EQUIVALENT.
EQUIVALENT ANCHORS SHALL HAVE AN APPROVED 1CC NUMBER.
3. EXPANSION ANCHORS SHOWN IN THESE DOCUMENTS SHALL BE TESTED AS
FOLLOWS: (HARDROCK OR LIGHTWEIGHT CONCRETE)
ANCHOR SIZE TORQUE (FT-lb)
8" 25
2" 40
8" 60
4" 110
WHERE EQUIVALENT ANCHORS ARE USED TORQUE VALUES SHOULD BE AS
STATED IN THE ICC REPORT.
POWDER ACTUATED FASTNERS
1. POWDER DRIVEN FASTENERS SHALL BE HILTI AS PER ICC-ESR-2269 OR APPROVED EQUAL.
BASE
MATERIAL
STEEL
FASTENER
TYPE
MINIMUM
EBEDMENT
MINIMUM
EDGE DISTANCE
MINIMUM
SPACING
CONCRETE
X-U STEEL 1/2" 1"
X-U W/ DX-KWIK 11
2 " 3" 4"
E. CONCRETE MASONRY CONSTRUCTION
GENERAL NOTES
SOIL DATA
SOIL DATA BY BSK ASSOCIATES PROJECT 'BSK G11-143-11F' DATED JANUARY 5, 2012.
SOIL ALLOWABLE BEARING PRESSURE AS PER SOIL REPORT
BEARING VALUE
a) CONTINUOUS FOOTING = 3000 PSF
b) PAD FOOTINGS = 3000 PSF VALUES IN a AND b ABOVE MAY BE INCREASED BY 13 FOR
WIND AND SEISMIC LOADS.
LATERAL RESISTANCE
c) PASSIVE PRESSURE = 200 PCF
d) COEFFICIENT OF FRICTION 0.35
ALL FOOTING EXCAVATIONS SHALL BE INSPECTED
BY SOIL ENGINEER PRIOR TO PLACING CONCRETE.
5.
EXCAVATION AND BACKFILL SHALL BE AS REQUIRED
BY SOILS ENGINEER'S RECOMMENDATION.
FOOTING DEPTH SHALL BE A MINIMUM OF 24"
BELOW LOWEST ADJACENT COMPACTED GRADES.
4.
3.
2.
1.
SOIL CORROSIVITY REFER TO SOIL REPORT SECTION 6.35.
CONCRETE MASONRY NOTES
UNITS SHALL BE CONCRETE BLOCK CONFORMING TO ASTM C90 WITH AN ULTIMATE
COMPRESSIVE STRENGTH OF F'm=1875 PSI, MEDIUM WEIGHT GRADE 'N' AND SHALL
BE STORED UNDER COVER AT THE JOB SITE. THE SPECIFIED STRENGTH IS FOR
FULL STRESS USED IN DESIGN AND SHALL BE VERIFIED BY PRISM TESTING OR BY
UNIT STRENGTH METHOD IN ACCORDANCE WITH IBC SEC. 2105.
UNITS SHALL BE SUFFICIENTLY MOIST AT THE TIME OF PLACING TO MINIMIZE
ABSORPTION OF WATER FROM MORTAR OR GROUT . UNITS SHALL BE FREE OF ALL
SUBSTANCES WHICH MIGHT IMPAIR THE BOND OF THE UNITS TO MORTAR AND
GROUT . USE ONLY FULL SIZE UNITS OR FULL SIZE UNITS CUT TO SIZE.
2.
READY MIXED CONCRETE GROUT SHALL ALSO CONFORM TO ASTM C-94.
GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF F'c = 2000PSI AT 28 DAYS. FOR USE IN CONCRETE BLOCK WITH F'm = 1875 PSI.
3.
MORTAR SHALL BE TYPE S CONFORMING ASTM C270-52T AND SHALL
BE ONE PART CEMENT, THREE PARTS SAND AND 1/4 PART LIME
PUTTY OR HYDRATED LIME, AND SHALL BE MACHINE MIXED.
4.
CEMENT FOR MORTAR AND GROUT SHALL HAVE A LOW ALKALI TYPE CONFORMING TO
ASTM C-150. LIME SHALL BE TYPE 'S' HYDRATED LIME CONFORMING TO ASTM C-20-6.
5.
ALL BLOCK REINFORCING SHALL HAVE A MINIMUM LAP OF 48 BAR DIAMETERS OR 2'-0"
MINIMUM PROVIDE A MINIMUM OF 1/2" OF GROUT BETWEEN UNITS AND REINFORCING STEEL.
6.
GROUT FILL ALL CELLS UNLESS NOTED OR SHOWN OTHERWISE .
CONSOLIDATE ALL GROUT EITHER BY VIBRATION OR PUDDLING.
7.
ALL CONCRETE BLOCK WALLS SHALL BE CONSTRUCTED UTILIZING COMMON
RUNNING BOND UNLESS NOTED OR SHOWN OTHERWISE.
8.
SPECIAL INSPECTION IS REQUIRED FOR CONCRETE BLOCK WORK UNLESS
NOTED OR SHOWN OTHERWISE.
9.
PROVIDE A MINIMUM OF 1" OF GROUT BETWEEN BOLTS OR INSERTS AND MASONRY UNITS.
10.
PROVIDE CLEAN OUT OPENINGS AT BOTTOM OF ALL VERTICALLY GROUTED CELLS
WHEN GROUT LIFT EXCEEDS 5'-0". GROUT LIFT SHALL NOT EXCEED 6'-0".
11.
CONSTRUCTION SHALL COMPLY WITH SECTION 2104 OF THE IBC BUILDING CODE.
12.
QUALITY ASSURANCE MEASURES SHALL COMPLY WITH SECTION 2105 OF THE IBC
BUILDING CODE.
13.
THE COMBINED ASSEMBLED MASONRY UNITS WALL SHALL CONSIST
OF MASONRY UNITS, MORTAR, AND SOLID GROUT. THE ASSEMBLED
CONCRETE MASONRY UNIT STRENGTH f'm=1500 psi MINIMUM
1.
14.
MAX W/CM
RATIO
0.50 0.50
WIND LOADS:
BASIC WIND SPEED (3-SEC. GUST) = 95 MPH
WIND EXPOSURE
ENCLOSURE CLASSIFICATION OPEN
= C
2.
(N) NEW MEMBER
FTG FOOTING
LEGEND
@ AT
Ø DIAMETER
CONN CONNECTION
CONT CONTINUOUS
CONC CONCRETE
THK THICK
E EXISTING MEMBER
RISK CATEGORY IV
FG FINISH GRADE
MAX MAXIMUM
MIN MINIMUM
TYP TYPICAL
BOTT BOTTOM
EW EACH WAY
OC ON CENTER
HORIZ HORIZONTAL
ARCH ARCHITECTURAL
L LONG / LENGTH
VERT VERTICAL
DWGS DRAWINGS
CMU CONCRETE MASONRY UNIT
REINF REINFORCEMENT
UNO UNLESS NOTED OTHERWISE
& AND
RETN RETAINING
11072
S-001
DS/HUAP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
BID SET RE-SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE SITE ACCESS AND
PHYSICAL SECURITY
DEFICIENCIES
VAMC, FRESNO, CA, 93703
570-19-107
Project Director
03-17-2023Revisions: Date: Dwg. of
35% SCHEMATIC DESIGN
65% DESIGN DEVELOPMENT
315 ARDEN AVE, SUITE #23,
t: 888.900.3823 www.schwabeng.com
GLENDALE, CA 91203
PROJECT NO.: S60204180.00
11/12/2021 06/07/2021
95% CONSTRUCTION DOCUMENT 07/18/2022
100% CONSTRUCTION DOCUMENT 10/03/2022
BID SET SUBMITTAL 10/31/2022
BID SET RE-SUBMITTAL 03/17/2023
INCL INCLUSIVE
FOUNDATION CONCRETE MAY BE PLACED DIRECTLY INTO
EXCAVATION (AS SHOWN) PROVIDED THE TRENCH WALLS
ARE STABLE AS DETERMINED BY THE SOIL ENGINEER.
1.
FOUNDATIONS SHALL BEAR ON ACCEPTABLE SOIL, PER
THE SOIL REPORT, AS DETERMINED BY THE SOIL
ENGINEER.
2.
NOTES:
FOOTING WIDTH PLUS 2"
AFTER CONC SET CLEAN
TO REMOVE ALL FRAGMENTS
AND SCUM TO EXPOSED COARSE
AGGREGATE
3 12 " HIGH STARTER WALL FOR
CONCRETE AND MASONRY WALLS
BELOW GRADE 2xCONT PLANK
TYP
FORMWORK NOT PERMITTED
BELOW GRADE UNLESS FULLY
FORMED
CLEAN OUT BOTTOM OF
FOOTING PRIOR TO
CONCRETE POUR
STAKES NOT PERMITTED
WITHIN FOOTING SECTION
6" MIN CONT
CLEAN OUT
TYP
4" MI
N.
NO
P
IP
ES
HE
RE
4" MI
N.
6" MI
N.
1'-6" MIN.
9"
6" MI
N.
MAX 8"Ø
OPENING
1 12" CLR
OPENING DETAIL @ (E) WALL
COMPACTED BACKFILL
FINISHED GRADE
TAMPED SAND
PIPE
NO EXCAVATION
BELOW THIS LINE
PLACE CONCRETE FILL AROUND SLEEVE
PRIOR TO POURING FOUNDATION. MAKE
SAME WIDTH AS FOOTING AND FULL WIDTH
OF PIPE TRENCH. MIN 2'-0"
(E) FTG WALL
PIPE
ALL SLEEVES TO BE MIN1"
CLEAR ALL AROUND PIPE
PIPEFOUNDATION
FOUNDATION
WALL
LA
P
RE
IN
FO
RC
IN
G
P
ER
TY
P
RE
IN
F D
ET
AI
L T
YP
SEE PLAN AND SECTIONS
FOR DIMENSION TYP.
LA
P
PE
R
TY
PI
CA
L
RE
IN
F D
ET
AI
L T
YP
TY
P.
0"
DOUBLE CURTAIN REINFORCING
SINGLE CURTAIN REINFORCING
PROVIDE HOOKS AS PER
TYPICAL REINFORCING
DETAIL TYP
PROVIDE HOOKS AS PER
TYPICAL REINFORCING
DETAIL TYP
HORIZ REINF TYP
LAP PER TYP REINF
DETAIL
'd' BAR DIAMETER
'D' = BAR BEND DIAMETER
6d FOR #3 THRU #8 8d FOR #9, #10, AND #11
CAP STIRRUPS MAY BE USED
WHEREVER 135 deg. CLOSED STIRRUPS
ARE SHOWN IN GRADE BEAM ONLY.
MAX.
SLOPE
4d
4d
2 12" MIN.
'D' 'D' 'D' 'D' d
6"
MI
N.
d M
IN
1'-
0"
MI
N.
SEE SCHEDULE
WIRE REINFORCING TOGETHER
180 DEG. BEND OFFSET 90 DEG. BEND
NOTE:
'd' BAR DIAMETER
135 DEG. BEND
'd' BAR DIAMETER
CAP STIRRUP
Ld (INCHES)
NOTE:
EXTEND BAR STRAIGHT
AS FAR AS POSSIBLE
AND BEND
FACE OF SUPPORT
TOP BARS ARE HORIZONTAL BARS SO PLACED THAT MORE
THAN 12" OF CONCRETE IS CAST IN THE MEMBER BELOW
THE BAR
BAR DEVELOPMENT LENGTH (Ld) SCHEDULE
ACI CLASS A TENSION SPLICE = 1.0 Ld LAP SPLICES FOR ACI CLASS B TENSION SPLICE = 1.3 Ld
BAR SIZE
TOP BARS
#3 #4 #5 #6 #7 #8 #9 #10 #11
OTHER BARS
f'c = 3000 PSI f'c = 4000 PSI
TOP BARS OTHER BARS
4" MIN.
6d
DOUBLE CURTAIN REINFORCING
CORNER INTERSECTION JAMB
SINGLE CURTAIN REINFORCING
SEE PLAN AND SECTIONS
FOR DIMENSIONS
2-#5 VERT
TYP UNO
1-#5 VERT
TYP UNO
4 - #5 VERT
TYP UNO
TY
P.0"LAP PER TYP REINF
DETAIL 2'-0" MIN
4 - #5 VERT UNO
HORIZONTAL
REINF TYP
SEE PLAN &
SECTION TYP
2-#5 VERT
TYP UNO
LA
P
PE
R
TY
P
RE
IN
F
DE
TA
IL
2'- 0"
MI
N
LA
P
PE
R
TY
P
RE
IN
F
DE
TA
IL
2'- 0"
MI
N
2'-0" MIN
A3'- 0"
MA
X
5'- 0"
MI
N.
E
MB
ED
#4 TIES @
12' OC UNO
3- #4 TIES WITHIN 5"
FROM TOP
#4 TIES @ 4" OC
3'- 0"
MI
N
EM
BE
D
(E) CONCRETE
SLAB ON GRADE
A
LIGHT POLE BY OTHERS
MAX 20 FEET
1"
GR
OU
T N
ON
-S
HR
IN
K
SECTION A-A
#4 TIES
6 - #6 VERT
1'-6" Ø
3" CLR
SE
E
CI
VI
L D
WG
S
ANCHOR BOLTS
DIAMETER BY
LIGHT POLE
MANUF
ANCHOR BOLTS
DIAMETER BY
LIGHT POLE
MANUF
CONCRETE
STRENGTH
f 'c = 3000 psi
@ 28 DAYS
6" MIN.
3" 5"
2"Ø HILTI KWIK BOLTS TZ
W/ MIN OF 2" EFFECTIVE
EMBED INTO CONC AND
2 34 " HOLE
TYP
CONC PAD
SLIDING GATE MOTOR
#4 @12" OC
SLIDING GATE
GUIDE POST
6" MI
N
#4 TIES
# 5 VERT
3'- 0"
MI
N
SECTION B-B
1'-9"
2'- 9"
6"
MI
N
TY
P
4-#4 TIES
4-# 5 VERT
B B
PLAN - FOOTING AT SLIDING
GATE GUIDE POST
1'- 0"
1'-0"
FOOTING DETAIL AT ROLLER TRACK
CONT FOOTING
2-#4 CONT
2-#4 CONT
TRACK BY MANUFACTURER
OF SLIDING GATE
#4 TIES
8 - #7 VERT2'-6
" Ø
3" CLR
ALT LAPS
SECTION C-C
6'- 6"
3'- 6"
M
IN
6" SQ SWING GATE POST
C C
PROVIDE 3-#4 TIES WITHIN
5" FROM TOP
#4 TIES
#7 VERT
A A 4'-
0"
3'- 6"
M
IN
E
MB
ED
4-#5 VERT
4x4 TUBE GATE POST
#4 @ 12" TIES
FENCE POST
A - A
1'-6"
#4 TIES
3-#4 TIES WITHIN
5 " FROM TOC
4- 3
8" Ø HILTI KB TZ2
AT MIN 16" OC
W/ MIN 2- 3 4" EMBED
INTO (E) CONC
(E) SLAB ON GRADE
MIN 4" FIELD VERIFY
CABINET
WT = 258 LBS
1'- 0"
CALL POST
WT = 330 LBS
4- 3
8" Ø HILTI KB TZ2
AT 90° W/ MIN 3" EMBED
INTO (E) CONC
2-#4 EA WAY
2'-0" SQ PAD
SLOPE TO DRAIN
SCALETYPICAL PIPE PENETRATION THROUGH FOOTING DETAIL 2NONE
SCALETYPICAL FOOTING TRENCH DETAIL 1NONE
SCALETYPICAL FOOTING CORNER & INTERSECTION DETAIL 3NONE
SCALETYPICAL REINFORCING BENDING & SPLICE DETAIL 4NONE
SCALETYPICAL LIGHT POLE FTG DETAIL 7NONE
SCALETYPICAL CMU WALL INTERSECTING AND ENDS DETAIL 5NONE
SCALETYP FOOTING DETAIL AT SWING GATE POST 11NONE
TYPICAL DETAILS
SCALENOT USED 6NONE
SCALE TYP SLIDING GATE FOUNDATION 10NONE
SCALEMAN-GATE POST AND FOUNDATION DETAIL 9NONE
SCALESLIDING GATE MOTAR PAD DETAIL 8NONE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
BID SET RE-SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE SITE ACCESS AND
PHYSICAL SECURITY
DEFICIENCIES
VAMC, FRESNO, CA, 93703
570-19-107
Project Director
03-17-2023Revisions: Date: Dwg. of
35% SCHEMATIC DESIGN
65% DESIGN DEVELOPMENT
315 ARDEN AVE, SUITE #23,
t: 888.900.3823 www.schwabeng.com
GLENDALE, CA 91203
PROJECT NO.: S60204180.00
11/12/2021 06/07/2021
95% CONSTRUCTION DOCUMENT 07/18/2022
100% CONSTRUCTION DOCUMENT 10/03/2022
BID SET SUBMITTAL 10/31/2022
BID SET RE-SUBMITTAL 03/17/2023
AP DS/HU
S-101 73 110
SCALETYPICAL CALL POST ANCHOR AND FOOTING DETAIL 12NONE
SCALEPISTOL CABINET ANCHOR DETAIL 13NONE
FENCE TYPE 3
ANTI-RAM BARRIER
FENCE TYPE 2
SEMI-PERMANENT
FENCE TYP
ANTI RAM BOLLARDS TYPE A
AT MAX 4'-0" CLR. SEE
'LEGEND' THIS SHEET TYP
ANTI RAM BOLLARDS TYPE A
AT OXYGEN TANK
SHED
FENCE TYPE 1
PERMANENT FENCE
TYP
SS-202
FENCE TYPE 3
ANTI-RAM BARRIER
ENLARGED ANTI-RAM
BOLLARD PLAN
FENCE TYPE 1
PERMANENT
FENCE
FENCE TYPE 1
PERMANENT FENCE
FENCE TYPE 4
WITH LOW PLANTER
WALL
4'-23 8"
4'-13 4"
FENCE TYPE 4
WITH LOW WALL
SIM NO RETN
CONDITION
SIM
ANTI RAM BOLLARDS
TYPE A SEE 'LEGEND' THIS
SHEET TYP
GATE PIER
& FDN
GATE PIER
& FDN
SIM
BUS
B U S
BUS
EL 308.5
EL 308.5
MAIN
ENTRANCE
SIGN
V A
M O N U M E N T
S
IG
N
M O N U M E N T
S
IG
N
S P E E D
B U M P
SOLAR PANELS
SOLAR PANELS
B-31
COMMUNITY
B-1
MAIN
B-3
ENGINEERING
B-2
BOILER PLANT
WAREHOUSE
B-32
OUTPATIENT
OPC
MENTAL
B-25
B-34
MENTAL HEALTH
HEALTH
FREEDOM
CLINIC
HOSPITAL B-24
LIBERTY
BLDG
LIVING
CENTER
VALOR BLDG
BLDG
B-27
MENTAL HEALTH
INDEPENDENCE BLDG
B-36
BARN
B-24
AUDITORIUM
B-24 BREEZEWAY
B-22
CHILLER
B-22A
CHILLER
W
AL
K
OF
H
ON
OR
MODULAR 2
LOT C
BBQ
PARKING LOT A
PARKING LOT B
PA
RK
IN
G
LO
T
C
PARKING LOT E
PA
RK
IN
G
LO
T
F
PARKING LOT G
PARKING LOT D
CLC
BUILDING
PA
RK
IN
G
LO
T
H
MOTORCYCLES
YIELD
YIELD
SS-202
SS-202 6
SS-202
SS-202
SS-202
SS-202
SS-202
SS-202
15'-77 8"
BOLLARDS TYPE B
SEE 'LEGEND' THIS
SHEET
TYP
BOLLARDS TYPE B
SEE 'LEGEND' THIS
SHEET
FENCE SITE PLAN
1" = 40'-0"1 SITE PLAN-SECURITY FENCE
N
4). THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF
THE JOB PRIOR TO STARTING CONSTRUCTION AND THE CONTRACTING
OFFICER REPRESENTATIVE SHALL BE NOTIFIED IMMEDIATELY OF ANY
DISCREPANCIES OR INCONSISTENCIES. DO NOT SCALE DIMENSIONS,
WHERE NO DIMENSIONS ARE PROVIDED, CONSULT WITH CONTRACTING
OFFICER REPRESENTATIVE FOR CLARIFICATION BEFORE PROCEEDING
WITH THE WORK.
NOTES:
1). FOR GENERAL NOTES AND TYPICAL DETAILS SEE SHEETS S-001 AND
S-101
2). FOR FOR FENCE TYPE , ELEVATIONS AND DIMENSIONS REFER TO THE
ARCHITECTURAL AS-101, AS-102 TO AS-109 INCLUSIVE.
ANTI-RAM RESISTANCE:
1) ANTI-RAM BARRIERS BOLLARDS, POST RAIL FENCES AND SHALL BE IMPACT TESTED AND
CERTIFIED TO BE CAPABLE OF STOPPING A 4000 POUND VEHICLE AT A SPEED OF 30 MILES
PER HOUR WITH A MAXIMUM PENETRATION DISTANCE OF 3.3 FEET. TESTING AND
CERTIFICATION SHALL BE IN ACCORDANCE WITH LATEST EDITION OF ASTM F2656, ASTM
F3016, OR AOS SD-STD-02.01. TESTED ANTI-RAM BARRIERS SHALL BE LISTED ON THE
DEPARTMENT OF DEFENCE "DoD ANTI-RAM VEHICLE BARRIER LIST".
VEHICLE BARRIERS
2) IN LIEU OF ANTI-RAM POST AND RAIL BARRIER CONTRACTOR MAY PROVIDE KNEE HIGH
MIN 3'-6" HIGH CONCRETE WALL. CERTIFICATION OF THE CONCRETE WALL SHALL BE AS
REQUIRED IN ITEM 1 ABOVE.
3) CONTRACTOR SHALL PROVIDE SHOP DRAWINGS, PRODUCTION DATA AND SAMPLES OF
ALL ANTI-RAM BARRIERS FOR REVIEW TO THE CONTRACTING OFFICER REPRESENTATIVE
PRIOR TO CONSTRUCTION.
4) FOR ANTI RAM BOLLARD SEE DETAILS 7, 8 AND 9 ON SHEET S-301
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
BID SET RE-SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE SITE ACCESS AND
PHYSICAL SECURITY
DEFICIENCIES
VAMC, FRESNO, CA, 93703
570-19-107
Project Director
03-17-2023Revisions: Date: Dwg. of
35% SCHEMATIC DESIGN
65% DESIGN DEVELOPMENT
315 ARDEN AVE, SUITE #23,
t: 888.900.3823 www.schwabeng.com
GLENDALE, CA 91203
PROJECT NO.: S60204180.00
11/12/2021 06/07/2021
95% CONSTRUCTION DOCUMENT 07/18/2022
100% CONSTRUCTION DOCUMENT 10/03/2022
BID SET SUBMITTAL 10/31/2022
BID SET RE-SUBMITTAL 03/17/2023
3). FOR LOCATION OF EXISTING UTILITIES REFER TO CIVIL DRAWINGS CI-09 TO
CI-12 INCLUSIVE. CONTRACTOR SHALL INVESTIGATE AND LOCATE EXISTING
UTILITIES PRIOR TO INSTALLING FOOTINGS. WHERE FOOTING INTERFERENCE
OCCURS CONTRACTOR SHALL INFORM THE CONTRACTING OFFICER
REPRESENTATIVE .
LEGEND:
-------------- ANTI RAM BOLLARD TYPE A SEE DETAILS 7, 8 AND 9 ON SHEET S-301
-------------- BOLLARD TYPE B SEE DETAIL 7/S-302 AND 8/S-302
AP DS/HU 74 110
SS-201
AutoCAD SHX Text Xref C:\Users\AP LAPTOP\Documents\PROJECTS\Schwab\Fresno Physical Security\Structural\Base\XR-STRUCT FENCE LAYOUT.dwg
ATTACK SIDE
PLAN ANTI-RAM POST CABLE FENCE
ELEVATION ANTI-RAM POST AND RAIL FENCE
8'-8" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-8"
73'-4"
3'-6" Ø
8'- 0"
3'-6" Ø
4'- 0"
9"Ø
3'- 0"
TYP
TY
P
4000 PSI
CONCRETE
TYP
NOTES:
1) FOR ANTI-RAM BARRIER NOTES SEE SHEET SS-201
2) ANTI-RAM FENCE SHOWN SHALL BE THE 'STALWART-M30 P1'
BY AMERISTAR OR EQUIVALENT.
#3 RINGS TYP
BY MANUFACTURER
#5 VERT TYP
BY MANUFACTURER
ATTACK SIDE
PL
AN
A
NT
I-R
AM
P
OS
T
CA
BL
E
FE
NC
E
(E) COMUNNITY
CENTER BLDG
(N) ANTI RAM FENCE BY AMERISTAR
RATED FOR M30 P1
SS-202
S-301
S-301
4'-0" SQ FTG TYP
@ PIERS
TYP
TYP
3"x 3"x
GA
POST
16" SQ
CMU PIERS TYP
2'- 6"W x 1 '-0
" C
ON
T F
TG
TY
P
3"x 3"x
GA
POST
" C
MU
W
AL
L
TY
P
S-301
TYP
S-302
METAL FENCE
SEE ARCHITECTURAL
SHEET AS-101
FENCE POST
8'-0" MAX TYP
S-302
(E) UNDERGROUND UTILITIES
WHERE OCCUR. SEE CIVIL
PLANS CI-09,CI-10,CI-11 AND CI-12
TYP
18" Ø x 3'-6"
DEEP FTG TYP
ANTI-RAM BOLLARDS AT 4'-0" CLR
MAXIMUM TYP
BOLLARD SHALLOW
FOUNDATION
METAL FENCE
S-301TYP 5
S-301
TYP AT FENCE
POST
3'- 0"W x 1 '-3
" C
ON
T F
TG
3"x 3"x
GA
POST 3"x 3"x
GA
POST 3"x 3"x
GA
POST
3"x 3"x
GA
POST
3"x 3"x
GA
POST3"x 3"x
GA
POST 3"x 3"x
GA
POST 3"x 3"x
GA
POST 3"x 3"x
GA
POST 3"x 3"x
GA
POST
" C
MU
W
AL
L
TY
P
RETAINING SIDE
CONCRETE SIDE
WALK SIDE
WALL FTG SEE
3/SS-202
S-301
2'-0" SQ CMUPIER
5'-0 " S
Q x 1'-
3"
TH
K
FT
G
SCALEENLARGED PLAN ANTI-RAM POST CABLE FENCE TYPE 3 11/4"=1'- 0"
ENLARGED PLANS
SCALEPLAN- ANTI-RAM WALL POST CABLE FENCE TYPE 4 AT BLDG 21/8"=1'- 0"
SCALEPARTIAL PLAN -SEMI-PERMANENT FENCE TYPE 2 41/4"=1'- 0"
SCALEPARTIAL PLAN - PERMANENT FENCE TYPE 1 31/4"=1'- 0"
SCALEENLARGED PLAN BOLLARD LAYOUT 51/4"=1'- 0"
SCALEPARTIAL PLAN - FENCE TYPE 4 AT CMU RETAINING WALL 61/4"=1'- 0"
SCALEPARTIAL PLAN - GATE PIER FOOTING 71/8"=1'- 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
BID SET RE-SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE SITE ACCESS AND
PHYSICAL SECURITY
DEFICIENCIES
VAMC, FRESNO, CA, 93703
570-19-107
Project Director
03-17-2023Revisions: Date: Dwg. of
35% SCHEMATIC DESIGN
65% DESIGN DEVELOPMENT
315 ARDEN AVE, SUITE #23,
t: 888.900.3823 www.schwabeng.com
GLENDALE, CA 91203
PROJECT NO.: S60204180.00
11/12/2021 06/07/2021
95% CONSTRUCTION DOCUMENT 07/18/2022
100% CONSTRUCTION DOCUMENT 10/03/2022
BID SET SUBMITTAL 10/31/2022
BID SET RE-SUBMITTAL 03/17/2023
AP DS/HU 75 110
SS-202
3x3 FENCE POST
NOTE:
FOR ALTERNATE
DETAIL SEE
DETAIL 4/ S-301
2'- 8"
MA
X
8"
6" SQ
℄POST & WALL
4-1 2" Ø F1554 GR 36
ANCHOR BOLTS
8"
EM
BE
D
CMU WALL
SEE PLAN
3-#5 CONT
#4 @ 18" BOTT
#5 CONT
1'- 3"
PLAN
BASE PLATE
DETAIL
8" THK PL
CMU WALL
SOLID GROUT
ALL CELLS
#5@16" VERT
@ ℄ OF WALL
#4 @ 16" HORIZ
2- #4 CONT
SECTION E-E
E E
SE
E
AR
CH
'L
SH
TS
A
S-
2 T O
AS
-10
9 I
NC
L F
OR
E
LE
VA
TIO
NS
4'-0"
1'- 3"
8-#6 VERT
#4 TIES @ 8" OC
5-#5 BOTT
EA WAY
VENEER SEE
ARCH'L PLANS
1'-4" SQ
CMU PIER
#6
#4 TIES
C C
SECTION C-C
2'- 0"
MI
N
FG
CONTINUE WALL AND FTG REBAR
THROUGH PIER AND FTG SPLICE AS
REQUIRED
Ø
LA
P
" M
IN
S
PL
IC
E
DOWELS TO MATCH
VERTICAL REINF TYP
SE
E
AR
CH
S
HT
S
AS
-10 2 T
O
AS
-10
IN
CL
US
IV
E
SEE PLAN
1'- 3"
2'- 8 M
AX
8"
3-#5 CONT
#4 @ 18" BOTT
#5 CONT
#5@16" VERT
@ ℄ OF WALL
#4 @ 16" HORIZ
2- #4 CONT
CMU WALL
SOLID GROUT
ALL CELLS
SE
E
AR
CH
'L
SH
TS
A
S-
2 T O
AS
-10
9 I
NC
L F
OR
E
LE
VA
TIO
NS
1'- 6"
6'- 0"
S-301
A A
PLAN- CONSECTIVE BOLLARD PLACEMENT DETAIL
4'-0" CLR MAX 4'-0" CLR MAX
ATTACK SIDE
4'-0"
FOR 3-ARRAY BOLLARD
MIN
FOR 3-ARRAY BOLLARD
MINCONT REBAR AND FTG
FOR MORE THAN 3 ARRAY
BOLLARDS. TYP
4'-0"
SEE PLAN
1'- 3"
2'- 8 M
AX
8"
3-#5 CONT
#4 @ 18" BOTT
#5 CONT
#5@16" VERT
@ ℄ OF WALL
2- #4 SPLICE
AT POST
SE
E
AR
CH
'L
SH
TS
A
S-
2 T O
AS
-10
9 I
NC
L F
OR
E
LE
VA
TIO
NSCMU WALL
SOLID GROUT
ALL CELLS
18"x18" CONCRETE
AT FENCE POST
#4 x 5'-0" HORZ
SPLICE BAR AT
POST
#4 x 5'-0" HORZ
SPLICE BAR AT
POST
#4 x 5'-0" HORZ
SPLICE BAR AT
POST
4 - #4x L BARS
EA WAY
3'- 2"
1'- 1"
SECTION A-ANOTES:
1) FOR ANTI-RAM BARRIER NOTES SEE SHEET SS-201
2) ANTI-RAM BOLLARDS SHOWN SHALL BE THE 'ASSA ABLOY-M30 P1' SHALLOW
BY AMERISTAR OR EQUIVALENT.
#5 @ 5" OC EW
TOP AND BOTT
MAT4 - #8 x4'-0" L PLACED
ABOVE BOTT MAT
TYP 4 PLACES
4'-0" TYP
#8 BARS
#8 BARS
8x16 TUBE TYP
8" Ø TYP
1'- 6"
6'- 0"
12'-0"
S-301
B B
PLAN- SINGLE BOLLARD DETAIL
ATTACK SIDE
3'- 2"
SECTION B-B
NOTES:
1) FOR ANTI-RAM BARRIER NOTES SEE SHEET SS-201
2) ANTI-RAM BOLLARDS SHOWN SHALL BE THE 'ASSA ABLOY-M30 P1' SHALLOW
BY AMERISTAR OR EQUIVALENT.
#5 @ 5" OC EW
TOP AND BOTT
MAT
4'-0" TYP
4 - #8 x4'-0" L PLACED
ABOVE BOTT MAT
8x16 TUBE TYP
8" Ø
(E) CONC
PAVING
1'-6" 6'-0"
ATTACK SIDE PROTECTED SIDE
3'- 2"
#8
#8
2- #8
#5 BARS
(E) CONC
PAVING
(E) ASPHALT PAVING
3'-0"
3-#5 CONT
#4 @ 18" BOTT
#5 CONT
#4 @ 16" HORIZ
2- #4 CONT
#5@16" VERT
@ ℄ OF WALL
10"
8" 2'-
0" 1'-
3"
WATERPROOF
BARRIER
PLANTER
10" CMU
SOLID GROUT
ALL CELLS
(E) CONC SIDE
WALK
#4 @ 18" BOTT
PLANTER
3x3 FENCE POST
NOTE:
FOR REMAINDER
OF INFORMATION
SEE DETAIL
6 / S-301
2'- 0"
MA
X
8"
8"
EM
BE
D
10" CMU
SOLID GROUT
ALL CELLS
1"
GR
OU
T
℄ CMU WALL / POST
(E) CONC SIDE
WALK
S-301
5'-0"
1'- 3"
12-#6 VERT
#4 TIES @ 8" OC
6-#5 BOTT
EA WAY
VENEER SEE
ARCH'L PLANS
2'-0" SQ
CMU PIER
#6
#4 TIES
D D
SECTION D-D
2'- 0"
MI
N
FG
CONTINUE WALL AND FTG REBAR
THROUGH PIER AND FTG SPLICE AS
REQUIRED
Ø
LA
P
" M
IN
S
PL
IC
E
DOWELS TO MATCH
VERTICAL REINF TYP
EMBED PLATE FOR GATE
HINGE CONN 2 PLACES
SEE DETAIL 5/S-302
SE
E
AR
CH
S
HT
S
AS
-10 2 T
O
AS
-10
IN
CL
US
IV
E
ALTERNATE USE CONCRETE
PIER WITH #4 TIES AT 6" OC
6" SQ
4-1 2" Ø F1554 GR 36
ANCHOR BOLTS
PLAN BASE PLATE
8" THK PL
SCALEFENCE POST TO CMU WALL CONN AT FENCE TYPE 1 1NONE
SCALESECTION THROUGH CMU WALL AT FENCE TYPE 1 2NONE
SCALESCTION AT CMU RETNG WALL AT FENCE TYPE 4 6NONE
SCALEPIER DETAIL AT PERMANENT FENCE TYPE 1 3NONE
SCALEFENCE TYPE 4 POST TO CMU RETNG WALL CONN 5NONE
SCALEALTERNATE FENCE POST DETAIL AT FENCE TYPE 1 4NONE
SCALE3 ARRAY AND MULTI ARRAY ANTI-RAM BOLLARDS AND FOUNDATION DETAIL 7NONE
SCALE
SINGLE ANTI-RAM BOLLARD AND FOUNDATION DETAIL 8NONE
SCALEGATE PIER AND FOUNDATION DETAIL AT FENCE TYPE 1 10NONE
SCALESECTION THROUGH SHALLOW MOUNT BOLLARD 9NONE
SECTION AND DETAILS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
BID SET RE-SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE SITE ACCESS AND
PHYSICAL SECURITY
DEFICIENCIES
VAMC, FRESNO, CA, 93703
570-19-107
Project Director
03-17-2023Revisions: Date: Dwg. of
35% SCHEMATIC DESIGN
65% DESIGN DEVELOPMENT
315 ARDEN AVE, SUITE #23,
t: 888.900.3823 www.schwabeng.com
GLENDALE, CA 91203
PROJECT NO.: S60204180.00
11/12/2021 06/07/2021
95% CONSTRUCTION DOCUMENT 07/18/2022
100% CONSTRUCTION DOCUMENT 10/03/2022
BID SET SUBMITTAL 10/31/2022
BID SET RE-SUBMITTAL 03/17/2023
SCALEPOST TO BASE PLATE CONNECTION 11NONE
AP DS/HU 76 110
S-301
METAL FENCE
SEE ARCHITECTURAL
AS-102
8'-0" MAX
8'- 0"
A A
A A
A - A
3'- 6"
3'- 0"
MI
N
EM
BE
D
4-#5 VERT
#3 @ 12" TIES
FENCE POST
FENCE POST
A - A
1'-6"
FENCE SEE
ARCHITECTURAL
A
S-302
1'- 9"
1'-9"
#4 TIES CLOSED
LOOP TIES
(E) UTILITY WHERE
OCCURS(N) CONCRETE
CAISSON
3-#6 TOP CONT.
3-#6 TOP CONT.
3" 3'-
3-#6 TOP
#4 CLOSED LOOP TIES @ 6" OC
4-#5 VERT
TYP
B B
(E) UTILITY WHERE
OCCURS
1'-0" CLR
TYP
4'-0" MAX
S-302
#3 @ 12" TIES
B - B
1'-3" Ø
8" THK PL
CMU PIER
4 - 3 4" Ø x 12" L
WELD STUDS TO
EMBED PL
ELEVATION - EMBED PLATE
1'-0" SQ
4 - 3 4 " Ø
WELDED STUDS
CMU PIER
EMBED PLATE
C C
4 MIN.
9" TYP
TYP
2-#5x DOWELS WELDED
TO BACK SIDE OF PL @ 4" OC
1'- 0"
TY
P
#5 WELDED
DOWELS
2'-6" SQ FTG
DD
4 -5 8 " Ø x F1554 GR36
ANCHOR BOLTS
PLAN - VERT BARRIER FTG
VERTICAL BARRIER
UNIT
WT = 350 lbs
D - D
1'- 0"
8" 4"
8"
EM
BE
D
4 - #4 L BARS
EW
4 - #4 BOTT EW
VERTICAL BARRIER
UNIT
SEE ARCHITECTURAL SHEETS
AS-103, AS-106 AND AS-601
1'-6"
3'- 0"
MI
N
6" O.D. GALVANIZED
STEEL PIPE -FILL WITH
CONCRETE.
CONCRETE CAP
TOP OF CONCRETE
WHERE OCCURS
CONCRETE MINIMUM
STRENGTH 4000 PSI
4'- 0"
6"
4-#5 VERT
#4 @ 12" OC
TIES
3-#4 TIES WITHIN
5 " FROM TOC
2'-6"
5'- 6"
MI
N
6" O.D. GALVANIZED
STEEL PIPE -FILL WITH
CONCRETE.
CONCRETE CAP
TOP OF A.C. PAVING OR
WHERE OCCURS
CONCRETE MINIMUM
STRENGTH 4000 PSI
4'- 0"
6"
6-#7 VERT
#4 @ 12" OC
TIES
3-#4 TIES WITHIN
5 " FROM TOC
SCALE(E) UTILITY AT FENCE TYPE 2 SEMI PERMANENT FDN 2NONE
SCALEFENCE TYPE 2 SEMI PERMANENT METAL FENCE FOUNDATION DETAIL 1NONE
SCALESECTION 4NONE
SCALEFOUNDATION DETAIL AT (E) UTILITY 3NONE
SCALEMORTIRIZED BARRIER UP-SWING GATE FOUNDATION DETAIL 6NONE
SCALE BOLLARD TYPE B DETAIL AT CONCRETE (RESTRAINED) 7NONE
SCALEBOLLARDTYPE B DETAIL AT ASHAPLT / SOIL (UNRESTRAINED) 8NONE
SECTION AND DETAILS
SCALEDETAIL - EMBED PLATE AT GATE PIER 5NONE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
BID SET RE-SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE SITE ACCESS AND
PHYSICAL SECURITY
DEFICIENCIES
VAMC, FRESNO, CA, 93703
570-19-107
Project Director
03-17-2023Revisions: Date: Dwg. of
35% SCHEMATIC DESIGN
65% DESIGN DEVELOPMENT
315 ARDEN AVE, SUITE #23,
t: 888.900.3823 www.schwabeng.com
GLENDALE, CA 91203
PROJECT NO.: S60204180.00
11/12/2021 06/07/2021
95% CONSTRUCTION DOCUMENT 07/18/2022
100% CONSTRUCTION DOCUMENT 10/03/2022
BID SET SUBMITTAL 10/31/2022
BID SET RE-SUBMITTAL 03/17/2023
AP DS/HU 77 110
S-302