Attachment-Bldg 143 ARCH as-builts .pdf
PDF 47 MB Posted
- Attached to
- 687-24-112 Install Door Operators B143 Federal contract opportunity
- Solicitation number
- 36C26025R0079_0001
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26025R0079 0003.pdf | ||
| Updated SOW.pdf | ||
| 36C26025R0079 0002.pdf | ||
| Attachment 2 - Divisional Price Breakout.xlsx | XLSX spreadsheet | |
| Attachment 1 - SOW 687-24-112 Replace Door Installation REV 7.docx | DOCX document | |
| Attachment 4 - WALLA WALLA WAGE DETERMINATIONS.pdf | ||
| Site Visit Information Amendment 36C26025R0079 0001.pdf | ||
| 36C26025R0079.pdf | ||
| Attachment 5 - Contractor Rules of Behavior.pdf | ||
| Attachment 3 - Limitations on Subcontracting 687-24-112 Replace Door Installation.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pl ot
Da te:
th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
FULLY SPRINKLERED
SMITHGROUP, INC.
500 Griswold Suite 1700 Detroit, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroup.com
CIVIL ENGINEER:
J-U-B ENGINEERS, Inc.
2810 West Clearwater Ave, Suite 201 Kennewick, WA 99336 T 509.783.2144 F 509.736.0790
DOOR HARDWARE:
Jenosky Consultanting, Inc.
Architectural Hardware Specifications 43422 West Oaks Drive #270 Novi, MI 48377-3300 T 248.496.7900
RADIATION SHEILDING DESIGN:
Diagnostic Physics, Inc.
P.O. Box 49587 Charlotte, NC 28277 T 704.541.9628 F 704.541.2843
SIGNAGE:
Inkspotdesign, Inc
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
T 248.960.115
320 W. Ohio Street, Suite 4W Chicago, IL 60654 T 312.337.9600 F 312.337.9876
DESIGN/BUILDER:LEVEL II DESIGN:
HDR Architecture, Inc.
440 S. Church Street, Suite 1000 Charlotte, NC 28202 Phone: (704) 338-6700
97 8654321
9/5 /20
2:
:09
P M
05AUG13
WALLA WALLA, WASHINGTON
AE0
COVER SHEET
PT JF 1 286
JONATHAN M. WAINWRIGHT MEMORIAL
VA MEDICAL CENTER
687-400
JONATHAN M. WAINWRIGHT MEMORIAL VA MEDICAL CENTER
MULTI-SPECIALTY OUTPATIENT CLINIC
ISSUED FOR CONSTRUCTION - COMPLETE SET
MARCH 27, 2012
WALLA WALLA, WASHINGTON
WALLA WALLA, WASHINGTON WALLA WALLA, WASHINGTON
RECORD DRAWINGS 05AUG13
Pl ot
Da te:
th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
SMITHGROUP, INC.
500 Griswold Suite 1700 Detroit, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroup.com
CIVIL ENGINEER:
J-U-B ENGINEERS, Inc.
2810 West Clearwater Ave, Suite 201 Kennewick, WA 99336 T 509.783.2144 F 509.736.0790
DOOR HARDWARE:
Jenosky Consultanting, Inc.
Architectural Hardware Specifications 43422 West Oaks Drive #270 Novi, MI 48377-3300 T 248.496.7900
RADIATION SHEILDING DESIGN:
Diagnostic Physics, Inc.
P.O. Box 49587 Charlotte, NC 28277 T 704.541.9628 F 704.541.2843
SIGNAGE:
Inkspotdesign, Inc
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
T 248.960.115
320 W. Ohio Street, Suite 4W Chicago, IL 60654 T 312.337.9600 F 312.337.9876
DESIGN/BUILDER:LEVEL II DESIGN:
HDR Architecture, Inc.
440 S. Church Street, Suite 1000 Charlotte, NC 28202 Phone: (704) 338-6700
97 8654321
9/5 /20
2:
:44
P M
05AUG13
WALLA WALLA, WASHINGTON
AE0.0
DRAWING LIST
PT JF 2 286
JONATHAN M. WAINWRIGHT MEMORIAL
VA MEDICAL CENTER
687-400
ARCHITECTURAL
SHEET
NUMBER SHEET NAME
AE3.5 MAIN ENTRY CANOPY REFLECTED CEILING PLAN - AREA B2
AE4.1.1 EXTERIOR ELEVATIONS
AE4.1.2 EXTERIOR ELEVATIONS
AE4.1.3 EXTERIOR ELEVATIONS - COURTYARD
AE4.1.10 FUTURE EXPANSION
AE4.2.1 BUILDING SECTIONS
AE4.2.2 BUILDING SECTIONS
AE4.3.1 EXTERIOR WALL SECTIONS
AE4.3.2 EXTERIOR WALL SECTIONS
AE4.3.3 EXTERIOR WALL SECTIONS
AE5.1.1 EXTERIOR PLAN DETAILS
AE5.1.2 EXTERIOR PLAN DETAILS
AE5.1.3 EXTERIOR PLAN DETAILS
AE5.1.4 EXTERIOR PLAN DETAILS
AE5.1.5 EXTERIOR PLAN DETAILS
AE5.1.6 EXTERIOR PLAN DETAILS
AE5.1.7 EXTERIOR PLAN DETAILS
AE5.2.1 EXTERIOR SECTION DETAILS
AE5.2.2 EXTERIOR SECTION DETAILS
AE5.2.3 EXTERIOR SECTION DETAILS
AE5.2.4 EXTERIOR SECTION DETAILS
AE5.2.5 EXTERIOR SECTION DETAILS
AE5.2.6 EXTERIOR SECTION DETAILS
AE5.2.7 EXTERIOR SECTION DETAILS
AE5.2.8 EXTERIOR SECTION DETAILS
AE5.2.9 EXTERIOR SECTION DETAILS
AE5.2.10 EXTERIOR SECTION DETAILS
AE5.2.11 EXTERIOR SECTION DETAILS
AE5.2.12 EXTERIOR SECTION DETAILS
AE5.2.13 EXTERIOR SECTION DETAIL
AE5.2.14 EXTERIOR SECTION DETAILS
AE5.2.15 EXTERIOR SECTION DETAILS
AE5.2.16 EXTERIOR SECTION DETAILS
AE5.2.17 EXTERIOR SECTION DETAILS
AE5.2.18 EXTERIOR SECTION DETAILS
AE5.4.1 COURTYARD THERAPY TRAINING SURFACE & ROOF DETAILS
AS5.6.1 GENERATOR ENCLOSURE GENERAL NOTES AND TYPICAL DETAILS
AS5.6.2 GENERATOR ENCLOSURE PLANS, ELEVATIONS & SECTION
AE6.1.1 STAIR & ELEVATOR PLANS & SECTIONS
AE6.1.2 STAIR DETAILS
AE6.3.1 STANDARD ELEVATOR GUIDE DETAILS
AE7.1.2 EXTERIOR CANOPY PLANS AND ELEVATIONS
AE9.2.1 PARTITION SYSTEMS
AE9.2.2 PARTITION SCHEDULE AND DETAILS
AE9.2.3 PARTITION SCHEDULE AND DETAILS
AE9.2.4 PARTITION SCHEDULE AND DETAILS
AE9.2.5 PARTITION SCHEDULE AND DETAILS
AE9.2.6 PARTITION SCHEDULE AND DETAILS
AE9.3.1 DOOR SCHEDULE - LEVEL 1
AE9.3.2 DOOR SCHEDULE - LEVEL 1 CONTINUED
AE9.3.3 DOOR SCHEDULE - LEVEL 2
AE9.3.4 DOOR SCHEDULE - LEVEL 2 CONTINUED
AE9.4.1 CEILING DETAILS
AF9.1.3 LEVEL 1 WALL PROTECTION PLAN
AF9.1.4 LEVEL 2 WALL PROTECTION PLAN
AF9.1.5 PEDESTRIAN WALKWAY WALL PROTECTION PLAN
AI7.1.1 ENLARGED PLAN DETAILS
AI8.1.1 INTERIOR ELEVATIONS
AI8.1.2 INTERIOR ELEVATIONS
AI8.1.3 INTERIOR ELEVATIONS
AI8.1.4 INTERIOR SECTIONS / ELEVATIONS - MAIN LOBBY
AI8.1.5 INTERIOR ELEVATIONS
AI8.1.6 INTERIOR ELEVATIONS
AI9.0.1 FINISH SCHEDULE LEGEND AND KEY
AI9.0.3 INTERIOR FINISH SCHEDULE LEVEL 1
AI9.0.4 INTERIOR FINISH SCHEDULE LEVEL 2
AI9.1.1 LEVEL 1 FINISH PLAN
AI9.1.2 LEVEL 2 FINISH PLAN
AI9.1.3 LEVEL 1 & 2 FLOOR COVERING PLAN - AREA B1
AI9.1.4 FLOOR TRANSITION DETAILS
AI9.9.1 INTERIOR DETAILS
AI9.9.2 INTERIOR DETAILS
AI9.9.3 ARCHITECTURAL WOODWORK
AI9.9.4 ARCHITECTURAL WOODWORK
AI9.9.5 INTERIOR DETAILS
AI9.8.01 LEVEL 1 SIGN LOCATION PLAN
AI9.8.02 LEVEL 2 SIGN LOCATION PLAN
ARCHITECTURAL
SHEET
NUMBER SHEET NAME
COBie Unnamed
AE1.0.1 BUILDING 86 DEMOLITION PLAN
AE1.0.2 BUILDING 86 RENOVATION DETAILS AND EXTERIOR ELEVATION
AE2.1 LEVEL 1 COMPOSITE FLOOR PLAN
AE2.1.1 LEVEL 1 FLOOR PLAN - AREA A1
AE2.1.2 LEVEL 1 FLOOR PLAN - AREA A2
AE2.1.3 LEVEL 1 FLOOR PLAN - AREA A3
AE2.1.4 LEVEL 1 FLOOR PLAN - AREA A4
AE2.2 LEVEL 2 COMPOSITE FLOOR PLAN
AE2.2.1 LEVEL 2 FLOOR PLAN - AREA A1
AE2.2.2 LEVEL 2 FLOOR PLAN - AREA A2
AE2.2.3 LEVEL 2 FLOOR PLAN - AREA A3
AE2.2.4 LEVEL 2 FLOOR PLAN - AREA A4
AE2.3 ROOF PLAN
AE2.4 PEDESTRIAN WALKWAY FLOOR PLAN - AREA B1
AE2.5 MAIN ENTRY CANOPY PLAN - AREA B2
AE2.6 LEVEL 1 FLOOR PLAN - MECHANICAL YARD - AREA B3
AE3.1 LEVEL 1 COMPOSITE REFLECTED CEILING PLAN
AE3.1.1 LEVEL 1 REFLECTED CEILING PLAN - AREA A1
AE3.1.2 LEVEL 1 REFLECTED CEILING PLAN - AREA A2
AE3.1.3 LEVEL 1 REFLECTED CEILING PLAN - AREA A3
AE3.1.4 LEVEL 1 REFLECTED CEILING PLAN - AREA A4
AE3.2 LEVEL 2 COMPOSITE REFLECTED CEILING PLAN
AE3.2.1 LEVEL 2 REFLECTED CEILING PLAN - AREA A1
AE3.2.2 LEVEL 2 REFLECTED CEILING PLAN - AREA A2
AE3.2.3 LEVEL 2 REFLECTED CEILING PLAN - AREA A3
AE3.2.4 LEVEL 2 REFLECTED CEILING PLAN - AREA A4
AE3.4 PEDESTRIAN WALKWAY REFLECTED CEILING PLAN - AREA B1
CIVIL
SHEET
NUMBER SHEET NAME
VF-101 TOPOGRAPHICAL SURVEY
VF-102 TOPOGRAPHICAL SURVEY
VF-103 TOPOGRAPHICAL SURVEY
CI-001 SYMBOLS AND LEGEND
CI-002 STAGING AND SEQUENCING PLAN
CD-101 DEMOLITION PLAN
CS-101 GEOMETRIC CONTROL PLAN
CS-102 SITE PLAN
CS-103 SITE LAYOUT PLAN
CG-101 TEMPORARY EROSION AND SEDIMENT CONTROL PLAN
CG-102 GRADING AND DRAINAGE PLAN
CU-101 SITE UTILITY PLAN
CU-102 FIRE LINE EXTENSION
CU-103 SEWER PROFILES
CU-104 WATER PROFILES
CU-105 ROADWAY PROFILE
CI-501 DETAIL SHEET 1
CI-502 DETAIL SHEET 2
CI-503 DETAIL SHEET 3
ELECTRICAL
SHEET
NUMBER SHEET NAME
E-001 ELECTRICAL ABBREVIATIONS AND SYMBOLS
E-002 ELECTRICAL SITE PLAN - OPC BUILDING
ES-001 ELECTRICAL ABBREVIATIONS AND SYMBOLS
ES-101 ELECTRICAL SITE PLAN - PHASE 1 PRE-DEMOLITION
ES-102 ELECTRICAL SITE PLAN - PHASE 2 DEMOLITION
ES-103 ELECTRICAL SITE PLAN - PHASE 3 SITE WORK
ES-501 ELECTRICAL DETAILS
ES-502 ELECTRICAL DETAILS
EP2.1 LEVEL 1 POWER PLAN
EP2.2 LEVEL 2 POWER PLAN
EP2.3 ROOF POWER PLAN
EP2.4 PHOTOVOLTAIC SYSTEM PLAN
EL3.1 LEVEL 1 LIGHTING PLAN
EL3.2 LEVEL 2 LIGHTING PLAN
EY4.1 LEVEL 1 COMMUNICATIONS PLAN
EY4.2 LEVEL 2 COMMUNICATIONS PLAN
EF4.1 LEVEL 1 FIRE ALARM PLAN
EF4.2 LEVEL 2 FIRE ALARM PLAN
EF4.3 CONNECTOR FIRE ALARM PLANS
E-401 ELECTRICAL ENLARGED PLANS
E-402 ELECTRICAL ENLARGED PLANS
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-601 ELECTRICAL SCHEDULES
E-602 ELECTRICAL DIAGRAMS - POWER ONE LINE
E-603 ELECTRICAL DIAGRAMS - PHOTOVOLTAIC ONE-LINE DIAGRAM
E-604 RISER DIAGRAMS CONDUIT, COPPER CABLING, FIBER OPTIC, GROUNDING.
E-605 RISER DIAGRAMS FIRE ALARM
E-606 RISER DIAGRAMS CATV, PUBLIC ADDRESS, NURSE CALL
E-607 RISER DIAGRAMS SECURITY/ACCESS CONTROL, CCTV
E-701 ELECTRICAL PANEL SCHEDULES FIRST FLOOR
E-702 ELECTRICAL PANEL SCHEDULES FIRST FLOOR
E-703 ELECTRICAL PANEL SCHEDULES FIRST FLOOR
E-704 ELECTRICAL PANEL SCHEDULES SECOND FLOOR
SKE-18 FLOOR BOXES
SKE-19 FLOOR BOXES
EQUIPMENT AND FURNISHINGS
SHEET
NUMBER SHEET NAME
AF2.EQ-1 EQUIPMENT LIST
AF2.EQ-2 EQUIPMENT LIST
AF2.1.1 LEVEL 1 EQUIPMENT & FURNISHINGS PLAN - AREA A1
AF2.1.2 LEVEL 1 EQUIPMENT & FURNISHINGS PLAN - AREA A2
AF2.1.3 LEVEL 1 EQUIPMENT & FURNISHINGS PLAN - AREA A3
AF2.1.4 LEVEL 1 EQUIPMENT & FURNISHINGS PLAN - AREA A4
AF2.2.1 LEVEL 2 EQUIPMENT & FURNISHINGS PLAN - AREA A1
AF2.2.2 LEVEL 2 EQUIPMENT & FURNISHINGS PLAN - AREA A2
AF2.2.3 LEVEL 2 EQUIPMENT & FURNISHINGS PLAN - AREA A3
AF2.2.4 LEVEL 2 EQUIPMENT & FURNISHINGS PLAN - AREA A4
AF687.1 CANTEEN EQUIPMENT & FURNISHINGS PLAN
AF687.2 CANTEEN EQUIPMENT & FURNISHINGS PLAN
FIRE PROTECTION
SHEET
NUMBER SHEET NAME
FX.0 FIRE PROTECTION ABRREVIATIONS AND SYMBOLS
FX2.1 FIRST FLOOR FIRE PROTECTION PLAN
FX2.2 SECOND FLOOR FIRE PROTECTION PLAN
FX2.3 FIRST & SECOND FLOOR CONNECTOR FIRE PROTECTION PLANS
FX5.0 FIRE PROTECTION DIAGRAMS
GENERAL
SHEET
NUMBER SHEET NAME
AE0 COVER SHEET
AE0.0 DRAWING LIST
AE0.1 STAGING / SEQUENCING PLAN
AE0.2 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS
AE0.3 TYPICAL TOILET ROOM MOUNTING HEIGHTS AND STALL CONFIGURATION DIAGRAMS
AE0.4 TYPICAL MOUNTING HEIGHTS AND DIMENSIONING CONVENTIONS
AE0.5 TYPICAL RULES FOR DETERMINING MOUNTING HEIGHTS AND LOCATIONS
AE0.6 TYPICAL REFLECTED CEILING PLAN LOCATIONS AND CONFIGURATIONS
AE1.0 CODE SUMMARY
AE1.1 LEVEL 1 LIFE SAFETY PLAN - AREA A1, A2, A3, A4
AE1.1.1 LEVEL 1 & 2 LIFE SAFETY PLAN - AREA B1
AE1.2 LEVEL 2 LIFE SAFETY PLAN - AREA A1, A2, A3, A4
LANDSCAPE
SHEET
NUMBER SHEET NAME
LI-101 IRRIGATION AREA PLAN
LP-101 PLANTING PLAN
LP-201 PLANTING DETAILS
PLUMBING
SHEET
NUMBER SHEET NAME
P0 PLUMBING ABBREVIATIONS AND SYMBOLS
PL1.0.1 UNDERGROUND PLUMBING PLAN AREA 1
PL1.0.2 UNDERGROUND PLUMBING PLAN AREA 2
PL1.0.3 UNDERGROUND PLUMBING PLAN AREA 3
PL1.0.4 UNDERGROUND PLUMBING PLAN AREA 4
PL1.1.1 FIRST FLOOR PLUMBING PLAN AREA 1
PL1.1.2 FIRST FLOOR PLUMBING PLAN AREA 2
PL1.1.3 FIRST FLOOR PLUMBING PLAN AREA 3
PL1.1.4 FIRST FLOOR PLUMBING PLAN AREA 4
PL1.2.1 SECOND FLOOR PLUMBING PLAN AREA 1
PL1.2.2 SECOND FLOOR PLUMBING PLAN AREA 2
PL1.2.3 SECOND FLOOR PLUMBING PLAN AREA 3
PL1.2.4 SECOND FLOOR PLUMBING PLAN AREA 4
PL1.3 FIRST AND SECOND FLOOR CONNECTOR - PLUMBING PLANS
PL1.4 ROOF LEVEL - PLUMBING PLAN
PG3.1 FIRST FLOOR MEDICAL GAS PLAN
PG3.2 SECOND FLOOR MEDICAL GAS PLAN
PG3.3 FIRST & SECOND FLOOR CONNECTOR MEDICAL GAS PLANS
PL4.0 PLUMBING ENLARGED PLANS
PL5.0 STORM RISER DIAGRAM
PL5.1 SANITARY AND VENT RISER DIAGRAM
PL5.2 SANITARY AND VENT RISER DIAGRAM
PL5.3 DOMESTIC WATER RISER DIAGRAM
PL5.4 MEDICAL GAS RISER DIAGRAM
PL6.1 PLUMBING DETAILS
PL6.2 DOMESTIC WATER HEATER DIAGRAM
PL6.3 NATURAL GAS DIAGRAM
PL7.0 PLUMBING SCHEDULES
STRUCTURAL
SHEET
NUMBER SHEET NAME
SS0.1 STRUCTURAL ABBREVIATIONS AND LEGEND
SS0.2 STRUCTURAL GENERAL NOTES
SS0.3 STRUCTURAL GENERAL NOTES
SS0.4 SPECIAL INSPECTION SCHEDULE
SS0.5 STRUCTURAL LOADING PLANS
SB1.1.1 FIRST FLOOR AND FOUNDATION PLAN
SB1.1.2 ENTRY CANOPY, SERVICE YARD & BLDG CONNECTOR FOUNDATION PLANS
SB2.1.1 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS
SB2.2.1 CONCRETE SECTIONS AND DETAILS
SB2.3.1 SLAB ON GRADE SCHEDULE, SECTIONS, AND DETAILS
SB2.4.1 ELEVATOR PIT/SHAFT SECTIONS AND DETAILS
SF1.2.1 SECOND FLOOR FRAMING PLAN
SF1.2.2 ENTRY CANOPY AND BLDG CONNECTOR FRAMING PLANS
SF1.3.1 ROOF FRAMING PLAN
SF1.3.2 MONITOR FRAMING PLAN
SF3.1.1 COLUMN SCHEDULE, SECTIONS, AND DETAILS
SF3.2.1 STEEL FRAMING SECTIONS AND DETAILS
SF3.2.2 STEEL FRAMING SECTIONS AND DETAILS
SF3.2.3 STEEL FRAMING SECTIONS AND DETAILS
SF3.3.1 COMPOSITE SLAB SECTIONS AND DETAILS
SF3.3.2 COMPOSITE SLAB SECTIONS AND DETAILS
SF3.4.1 ROOF SECTIONS AND DETAILS
SF4.1.1 STRUCTURAL EXTERIOR WALL ELEVATIONS
SF4.1.2 STRUCTURAL EXTERIOR WALL ELEVATIONS
SF4.1.3 STRUCTURAL EXTERIOR WALL ELEVATIONS
SF4.2.1 EXTERIOR WALL SECTIONS AND DETAILS
SF5.1.1 TYPICAL MASONRY WALLS, SECTIONS AND DETAILS
SF6.1.1 SEISMIC REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS
MECHANICAL
SHEET
NUMBER SHEET NAME
M0 MECHANICAL ABBREVIATIONS AND SYMBOLS
MH2.1.1 FIRST FLOOR HVAC PLAN AREA 1
MH2.1.2 FIRST FLOOR HVAC PLAN AREA 2
MH2.1.3 FIRST FLOOR HVAC PLAN AREA 3
MH2.1.4 FIRST FLOOR HVAC PLAN AREA 4
MH2.1.5 FIRST FLOOR HVAC PLAN AREA B1
MH2.2.1 SECOND FLOOR HVAC PLAN AREA 1
MH2.2.2 SECOND FLOOR HVAC PLAN AREA 2
MH2.2.3 SECOND FLOOR HVAC PLAN AREA 3
MH2.2.4 SECOND FLOOR HVAC PLAN AREA 4
MH2.2.5 SECOND FLOOR HVAC PLAN AREA B1
MH2.3.0 ROOF LEVEL HVAC PLAN
MP3.1 FIRST FLOOR HVAC PIPING PLAN
MP3.2 SECOND FLOOR HVAC PIPING PLAN
MP3.3 FIRST & SECOND FLOOR CONNECTOR HVAC PIPING PLANS
M4.0 ENLARGED MECHANICAL ROOM PLANS
M4.1 MECHANICAL SECTIONS
M4.2 MECHANICAL SECTIONS
M4.3 MECHANICAL SECTIONS
M4.4 MECHANICAL SECTIONS
M5.0 HVAC FLOW DIAGRAM # 1
M5.1 HVAC FLOW DIAGRAM # 2
M6.1.1 HVAC DETAILS
M6.1.2 MECHANICAL AHU DETAILS
M6.2.1 HVAC PIPING DETAILS
M6.2.2 HVAC PIPING DETAILS
M6.3.1 HVAC MISC. DETALS
M6.3.2 HVAC MISC. DETALS
M7.0 MECHANICAL SCHEDULES
M7.1 MECHANICAL SCHEDULES
M7.2 MECHANICAL SCHEDULES
M7.3 MECHANICAL SCHEDULES
M7.4 MECHANICAL SCHEDULES
M8.1 CONTROL DIAGRAMS
M8.2 CONTROL DIAGRAMS
M8.3 CONTROL DIAGRAMS
M8.4 CONTROL DIAGRAMS
M8.5 CONTROL DIAGRAMS
M8.6 CONTROL DIAGRAMS
M8.7 CONTROL DIAGRAMS
M8.8 CONTROL DIAGRAMS
L
WO
S
ONLY
PARKING
NO
PARKING
NO
L
WO
S
AFM
AFM
AFM
AF
M
AFM
AFM
PATIENT
ACCESS
RRU ACCESS
SERVICE ACCESS
NEW SITEWORK
SHOWN HALFTONE
1A
1A 1A
1B
1C
1D
1E2A
OUTLINE OF NEW
BUILDING
BLDG 129
(Existing Generator)
NEW GENERATOR
& ENCLOSURE
3A
3B
3C
3D
PHASING LEGEND
WORK PERFORMED DURING
SEQUENCE 1
WORK PERFORMED DURING
SEQUENCE 2
WORK PERFORMED DURING
SEQUENCE 3
MAINTAIN ACCESS ROUTES TO
EXISTING FACILITIES
Pl ot
Da te:
th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
FULLY SPRINKLERED
SMITHGROUP, INC.
500 Griswold Suite 1700 Detroit, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroup.com
CIVIL ENGINEER:
J-U-B ENGINEERS, Inc.
2810 West Clearwater Ave, Suite 201 Kennewick, WA 99336 T 509.783.2144 F 509.736.0790
DOOR HARDWARE:
Jenosky Consultanting, Inc.
Architectural Hardware Specifications 43422 West Oaks Drive #270 Novi, MI 48377-3300 T 248.496.7900
RADIATION SHEILDING DESIGN:
Diagnostic Physics, Inc.
P.O. Box 49587 Charlotte, NC 28277 T 704.541.9628 F 704.541.2843
SIGNAGE:
Inkspotdesign, Inc
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
T 248.960.115
320 W. Ohio Street, Suite 4W Chicago, IL 60654 T 312.337.9600 F 312.337.9876
DESIGN/BUILDER:
TRUE NORTH PROJECT NORTH
LEVEL II DESIGN:
HDR Architecture, Inc.
440 S. Church Street, Suite 1000 Charlotte, NC 28202 Phone: (704) 338-6700
97 8654321
9/5 /20
2:
:57
P M
05AUG13
WALLA WALLA, WASHINGTON
AE0.1
STAGING / SEQUENCING PLAN
PT JF 3 286
JONATHAN M. WAINWRIGHT MEMORIAL
VA MEDICAL CENTER
687-400
SCALE: 1" = 50'-0" REF. A6 ON AE2.6E1 STAGING AND PHASING PLAN - SEQUENCES 1 & 2
SCALE: 1" = 50'-0" REF. A6 ON AE2.6E5 STAGING AND PHASING PLAN - SEQUENCE 3
1A - RE-DESIGNATE THE EAST CAMPUS ENTRY (CHESTNUT STREEET) AS THE MAIN PUBLIC ACCESS ON A TEMPORARY BASIS. ROUTE ALL CONSTRUCTION TRAFFIC VIA
THE NORTH CAMPUS ENTRY (POPLAR/AVERY STREET).
1B - PROVIDE/CONSTRUCT TEMPORARY EAST CONNECTION FROM BUILDING 74 PARKING OVAL TO PERIMETER PARADE GROUND DRIVE FOR ACCESS TO EXISTING BUILDING 74 DROP-OFF. REMOVE PORTION AS REQUIRED OF ENCLOSED NORTH-SOUTH WALKWAY AT NORTH SIDE OF BUILDING 86.
1C - INSTALL NEW GENERATOR (AND ENCLOSURE) FOR BUILDING 86.
1D - CONSTRUCT NEW SOUTH ACCESS DRIVE TO BUILDING 86 LOADING DOCK. INSTALL BASE COURSE PAVING ONLY; REPAIR BASE COURSE AS REQUIRED AND
INSTALL TOPPING AT COMPLETION OF OPC (FOLLOWING ALL UTILITY INSTALLATIONS).
1E - DEMARCATE TEMPORARY ACCESS TO RESIDENTIAL RECOVERY FACILITY.
2A - ASSUME CONTROL OF PROJECT SITE PROPER. RESTRICT ACCESS AND CONSTRUCT NEW BUILDING, PARKING AND DRIVES.
3A OCCUPY NEW OPC.
3B COMPLETE CONSTRUCTION OF SOUTH DRIVE INCLUDING CONNECTION TO NEW WEST DRIVE.
3C COMPLETE CONSTRUCTION OF RECONFIGURED DRIVE, HC PARKING AND LANDSCAPING BETWEEN BUILDINGS 74 AND 86.
3D COMPLETE CONSTRUCTION AND INSTALL OF PAVING TOPPING AT DRIVE AND SERVICE YARD FOR LOADING DOCK, BUILDING 86.
GENERAL NOTES:
THE SHOWN SUB-SEQUENCES ARE CONCEPTUAL AND MAY BE MODIFIED AS APPROPRIATE.
1. THIS SEQUENCING PLAN IS INTENDED TO IDENTIFY A CONCEPT ONLY OUTLINING GENERAL PARAMETERS FOR STAGING AND SEQUENCING OF CONSTRUCTION FOR THE PROPOSED BUILDING AND SITE IMPROVEMENTS. FINALIZATION OF THE PLAN IS TO BE COMPLETED BY THE DESIGN/BUILD CONTRACTOR DURING PREPARATION OF DESIGN AND CONSTRUCTION DOCUMENTS AND IS TO BE COORDINATED WITH AND REVIEWED/APPROVED BY THE WAINWRIGHT VAMC. THE FINAL PLAN DEVELOPED IS TO INCLUDE ANY AND ALL ADDITIONAL SEQUENCES OR SUB-SEQUENCES AS MAY BE REQUIRED TO IMPLEMENT THE WORK WHILE MAINTAINING ACCESSES SHOWN AND OPERATIONS OF ADJACENT FACILITIES IN A MANNER ACCEPTABLE THE WAINWRIGHT VAMC.
2. THE FINAL SEQUENCING/STAGING PLAN IS ALSO TO BE COORDINATED WITH AND REVIEWED/APPROVED BY THE WALLA WALLA FIRE DEPARTMENT (WWFD). PROVISION FOR ACCESS INTO AND AROUND THE SITE FOR FIRE-FIGHTING VEHICLES DURING CONSTRUCTION OF THE PROJECT IS TO INCLUDE AS A MINIMUM THE FOLLOWING REQUIREMENTS (UNLESS OTHERWISE DIRECTED BY
THE WWFD):
· - PROVIDE ACCESS TO WITHIN 150 FEET OF ALL EXISTING BUILDINGS AND STRUCTURES.
· - NO ACCESS WAY, ROAD OR DRIVE SHALL HAVE A DEAD-END GREATER THAN 150 FEET
· - CAPACITY OF ANY WAY, ROAD OR DRIVE TO BE POTENTIALLY UTILIZED BY FIRE-FIGHTING
VEHICLES SHALL SUPPORT AT LEAST 85,000 LBS.
3. ALL TEMPORARY CONSTRUCTION INSTALLED DURING SEQUENCING AND STAGING OF THE PROJECT IS TO BE COMPLETELY REMOVED WHEN NO LONGER REQUIRED AND AREAS OF THE SITE INVOLVED IN SUCH WORKS ARE TO BE FULLY RESTORED TO THEIR
FORMER CONDITION AND APPEARANCE.
SEQUENCE 1
SEQUENCE 2
SEQUENCE 3
PRE-CONSTRUCTION
WAINWRIGHT VAMC TO CLOSE EXISTING PARKING AREAS WITHIN THE NEW OPC PROJECT SITE AND DESIGNATE ALTERNATE PARKING FOR VISITORS, PATIENT AND STAFF OF BUILDINGS 74 AND 86. DESIGN-BUILD CONTRACTOR TO COORDINATE CONSTRUCTION START
DATE WITH THE VAMC RE-DESIGNATION OF PARKING.
AB
A
ANCHOR BOLT
ACT ACOUSTICAL CEILING TILE
ACP
AD
ACOUSTICAL CEILING PANEL
AREA DRAIN
ADDL ADDITIONAL
ADH
ADDITIONAL
ADJ
ADHESIVE
ADJ
ADJUSTABLE
AFF
ADJACENT
AFG
ABOVE FINISH FLOOR
AFS
ABOVE FINISH GRADE
AGGR
ABOVE FINISH SLAB
ALUM
AGGREGATE
ALT
ALUMINUM
ANOD
ALTERNATE
APPROX
ANODIZED
ARCH
APPROXIMATE(LY)
ACS PNL ACCESS PANEL
ARCHITECT(URAL)
ASPH ASPHALT
AVG AVERAGE
BB
B
BULLETIN BOARD
BD BOARD
BTWN
BLDG
BETWEEN
BUILDING
BM
BOT
BENCHMARK
BOTTOM
BITUM BITUMINOUS
BOS BOTTOM OF STEEL
BRG BEARING
BSMT BASEMENT
CAB
C
CABINET
CB CATCH BASIN
CCT
CG
CUBICLE CURTAIN TRACK
CORNER GUARD
CEM
CER
CEMENT, CEMENTITIOUS
CERAMIC
CCTV CLOSED CIRCUIT TELEVISION
CH BD CHALKBOARD
CI CAST IRON
CJ CONTROL JOINT
CL
CLG
CLR
CMU
CNTR
COL
CONC
CONF
CONN
CONSTR
CONT
CONTR
CORR
CPT
CSK
CSP
CSWK
CU
CW
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COUNTER
COLUMN
CONCRETE
CONFERENCE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CORRUGATED
CARPET
COUNTERSUNK
COMBINATION STANDPIPE
CASEWORK
CUBIC
COLD WATER
D
D
DEPTH
DBL DOUBLE
DBL ACT DOUBLE ACTING
DEG DEGREE
DEMO DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIM PT DIMENSION POINT
DISP DISPENSER
DIST DISTANCE
DN DOWN
DR DRAIN
DS DOWNSPOUT
DSP DRY STANDPIPE
DT DRAPERY TRACK
DWG DRAWING
DWGS DRAWINGS
(E)
E
EXISTING
EA EACH
EDR EQUIPMENT DRAWING
EG EDGE GUARD
EIFS EXTERIOR INSULATION FINISH SYSTEM
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EP ELECTRICAL PANEL
EPB ELECTRICAL PANEL BOARD
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESCAL ESCALATOR
EST ESTIMATE(D)
EWC ELECTRIC WATER COOLER
EXC EXCAVATED
EXH EXHAUST
EXP EXPANSION
EXP JT EXPANSION JOINT
EXT EXTERIOR
F/F
F
FACE TO FACE
FA FIRE ALARM
FAS FIRE ALARM STATION
FB FLAT BAR
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FF FINISH FACE
FHC FIRE HOSE CABINET
FH/FEC FIRE HOSE / FIRE EXTINGUISHER CABINET
FHMS FLAT HEAD MACHINE SCREW
FHWS FLAT HEAD WOOD SCREW
FHY FIRE HYDRANT
FLAM FLAMMABLE
FLASH FLASHING
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF
FSB FOLDING SHOWER BENCH
FSTNR FASTENER
FT FOOT, FEET
FTG FOOTING
FURN FURNITURE
FXTR FIXTURE
G
G
GAS
H
H
HIGH
GA GAUGE, GAGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GLU LAM GLUE LAMINATED
GLZ GLAZING
GR GRADE OR GRADING
GVL GRAVEL
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
ID
I
INSIDE DIAMETER
JAN
J
JANITOR
KG
K
KILOGRAM
L
L
LENGTH, LONG
M
M
METERS
(N)
N
NEW
OC
O
ON CENTER
PA
P
PUBLIC ADDRESS
QT
Q
QUARRY TILE
R
R
RISER
S SOUTH
T
T
TREAD
VAC
V
VACUUM
W
W
WEST
XFMR
X
TRANSFORMER
YD
Y
YARD
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HOUR
HVAC HEATING-VENTILATION-AIR CONDITIONING
IN INCH
INCAND INCANDESCENT
INCL INCLUDE, INCLUDING
INFO INFORMATION
INSUL INSULATION
INTR INTERIOR
INV INVERT
IVT INTRAVENOUS TRACK
JST JOIST
JT JOINT
KIT KITCHEN
KPL KICK PLATE
KS KNEE SPACE
LAB LABORATORY
LAM LAMINATE, LAMINATION
LAV LAVATORY
LB POUND
LED LIGHT EMITTING DIODE
LF LINEAR FOOT
LG LENGTH
LIN LINEAR
LL LEAD LINED
LPT LOW POINT
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LVR LOUVER
HW HOT WATER
S
MACH MACHINE
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MC MEDICINE CABINET
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING
MM MILLIMETERS
MO MASONRY OPENING
MOD MODULE, MODULAR
MTD MOUNTED
MTG MOUNTING
MVBL MOVABLE
MULL MULLION
NA NOT APPLICABLE
NAT NATURAL
NE NORTHEAST
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOICE REDUCTION COEFFICIENT
NTS NOT TO SCALE
NW NORTHWEST
OA OVERALL
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED-CONTRACTOR INSTALLED
OFOI OWNER FURNISHED-OWNER INSTALLED
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
OVHD OVERHEAD
OZ OUNCE
PART PARTIAL
PBD PARTICLEBOARD
PBX PRIVATE TELEPHONE EXCHANGE
PCF POUNDS PER CUBIC FOOT
PCI POUNDS PER CUBIC INCH
PERF PERFORATED
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PI POINT OF INTERSECTION
PL PLATE
PLAM PLASTIC LAMINIATE
PLAS PLASTER
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNEU PNEUMATIC
PNL PANEL
PNL BD PANEL BOARD
PNT PAINT
PORT PORTABLE
PP PUSH PLATE
PPM PARTS PER MILLION
PR PAIR
PRCST PRECAST
PREP PREPARATION
PREFAB PREFABRICATION
PRKG PARKING
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTN PARTITION
PTS PNEUMATIC TUBE STATION
PVC POLYVINYL CHLORIDE
PVG PAVING
PVMT PAVEMENT
PWR POWER
QTR QUARTER
QTY QUANTITY
RA RETURN AIR
RAD RADIUS
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
RD ROOF DRAIN
RECT RECTANGULAR
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE (D) (ING) (MENT)
REQD REQUIRED
REQT REQUIREMENT
RESIL RESILIENT
RET RETURN
REV REVISION
RF RESILIENT FLOORING
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHWS ROUND HEAD WOOD SCREW
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RWL RAIN WATER LEADER
SA SUPPLY AIR
SB SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SCRN SCREEN
SD STORM DRAIN
SE SOUTHEAST
SECT SECTION
SEG SEGMENT
SEP SEPARATION OR SEPARATE
SEP JT SEPARATION JOINT
SHT SHEET, SHEETING
SHWR SHOWER
SHV SHELVES, SHELVING
SIM SIMILAR
SK SINK
SMS SHEET METAL SCREW
SP SPACE, SPACED, SPACING
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS SANITARY SEWER
SSK SERVICE SINK
SST STAINLESS STEEL
ST STREET
STA STATION
STAG STAGGERED
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
STS SELF-TAPPING STEEL
SUSP SUSPENDED
SUSP CLG SUSPENDED CEILING
SVCE SERVICE
SW SOUTHWEST
SYMM SYMMETRICAL
SYST SYSTEM
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TC TOP OF CONCRETE, TOP OF CURB
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
THERM THERMAL
THK THICK, THICKNESS
THRES THRESHOLD
THRU THROUGH
TMPD GL TEMPERED GLASS
TO TOP OF
TOR TOP OF RAILING
TOS TOP OF STEEL
TOT TOTAL
TOW TOP OF WALL
TP TOP OF PAVEMENT
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
UC
U
UNDER COUNTER
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTABLE POWER SUPPLY
UTIL UTILITY
VB VALVE BOX
VCT VINYL COMPOSITION TYLE
VERT VERTICAL
VEST VESTIBULE
VIT VITREOUS
VP VENT PIPE
VOL VOLUME
VWC VINYL WALL COVERING
W/ WITH
W/O WITHOUT
W/W WALL TO WALL
WC WATER CLOSET OR WALL COVERING
WD WOOD
WDW WINDOW
WGL WIRE GLASS
WCHR WHEELCHAIR
WM WIRE MESH
WO WHERE OCCURS
W/O WITHOUT
WPT WORKING POINT
WR WATER RESISTANT
WSCT WAINSCOT
WSP WET STANDPIPE
WT WEIGHT
WTHPRF WEATHERPROOF
WTRPRF WATERPROOF
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
CCR CARD CONTROL READER
BUR BUILT UP ROOFING SYSTEM
CT CERAMIC TILE
FRZ FREEZER
FRT FIRE RETARDANT TREATMENT
EX-BR EXISTING BRICK
BASE CABINETS
BASE AND WALL CABINETS
WALL CABINETS
TOILET PARTITION AND DOOR
TOILET - WALL HUNG
URINAL - FLOOR/WALL HUNG
LAVATORY - COUNTERTOP
LAVATORY - PEDESTAL/WALL HUNG
GENERAL SYMBOLS
PLUMBING SYMBOLS
10' - 0"
HANDRAIL
BUMPER GUARD
EDGE GUARD
NIC NOT-IN-CONTRACT ITEMS
10' - 0"
10' - 0"
JANITOR'S RECEPTOR
DRINKING FOUNTAIN / EWC
EG
DIMENSION SYMBOLS
UTILITY SINK
BATHTUB
SHOWER
FLOOR DRAIN IN SLOPING FLOOR
FEC
FEC
FEXT
FEC
FIRE EXTINGUISHER
BRACKET MOUNTED
FIRE EXTINGUISHER
SURFACE MOUNTED
FIRE EXTINGUISHER CABINET
SEMI-RECESSED
FIRE EXTINGUISHER CABINET
RECESSED
DIMENSION SHOWN TO:
- STRUCTURAL GRID
- LAYOUT GRID
GRID LINE TYPICAL
DIMENSION SHOWN TO:
- CENTERLINE OF ASSEMBLY
- CENTER OF OPENING
- CENTER OF EQUIP/ FURN
CENTER LINE TYPICAL
DIMENSION SHOWN TO:
- PARTITION ASSEMBLY
- EDGE OF DOOR OPENING
- OTHER BUILDING ELEMENT
- WPT INDICATED ON DETAIL
FD
OVERHEAD ROLLING
SECTIONAL OR BIFOLD DOOR
PAIR DOORS - UNEQUAL SIZES
DOUBLE ACTING DOOR
SINGLE OPENING DOOR
2 PANEL BI-FOLD DOOR
PAIR - BI FOLD DOOR
DOOR OPENING MARK
PAIR DOORS - EQUAL SIZES
PAIR DOORS - DOUBLE EGRESS
DOOR WITH SIDE LIGHT
SLIDING DOOR - BETWEEN JAMBS
SLIDING POCKET DOOR
INTERIOR GLAZED WINDOW
ARCHITECTURAL
2'X4' LAY IN ACOUSTIC
TILE CEILING
2'X2' LAY IN ACOUSTIC
TILE CEILING
GYPSUM BOARD
ACCESS PANELAP
MECHANICAL
SUPPLY GRILLE
RETURN GRILLE
EXHAUST GRILLE
LINEAR DIFFUSER
SPRINKLER HEAD - CLG MOUNT
SPRINKLER HEAD - WALL MOUNT
ELECTRICAL
MISCELLANEOUS
2'X4' FLUORESCENT FIXTURE
2'X2' FLUORESCENT FIXTURE
1'X4' FLUORESCENT FIXTURE
FLUORESCENT STRIP FIXTURE
RECESSED DOWN LIGHT
WALL WASH
TRACK LIGHTING
EXIT SIGN, SINGLE-SIDED
EXIT SIGN, DOUBLE-SIDED
FIRE ALARM
SPEAKER
SMOKE DETECTOR
WIRELESS INTERNETW
P
S
F
HEIGHT OF CEILING FINISH
ABOVE FINISH FLOOR
+12'-8"
SECOND LEVEL
+10'-0"
BUILDING SECTION
WALL SECTION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
WALL SECTION
WALL SECTION NUMBER
NORTH ARROW REFERENCE
PROJECT NORTH
90.
00°
NEW GRID
IDENTIFICATION
EXISTING GRID
IDENTIFICATION
LAYOUT GRID LINES
BASIC DRAWING TITLE
SHEET WHERE DRAWN
DIRECTION OF VIEW
LEVEL LINE
REVISION EXTENT
ROOM NAME AND NUMBER
PLAN DETAIL REFERENCE
SECTION DETAIL REFERENCE
DETAIL REFERENCE
EXTERIOR ELEVATION
A102 2
INTERIOR ELEVATION REFERENCE
SEE PARTITION SYMBOL
DESCRIPTION ON SHEET AE9.2.1
PARTITION TYPE IDENTIFICATION MARK
ELEVATION NUMBER AND
DIRECTION
SHEET WHERE DRAWN
SHEET WHERE DRAWN
ELEVATION NUMBER AND
DIRECTION OF VIEW
SHEET WHERE DRAWN,
HYPHEN INDICATES DETAIL
ON SAME SHEET.
DETAIL NUMBER
DETAIL NUMBER
SHEET WHERE DRAWN,
DASH TEXT INDICATES
DETAIL ON SAME SHEET
SHEET WHERE DRAWN
ELEVATION NUMBER AND
DIRECTION
AX.X.X X
WINDOW AND LOUVER TYPE MARK
SEE CORRESPONDING
NUMBER ON SCHEDULE
NAME OF LEVEL
INDICATES HEIGHT ABOVE
PROJECT DATUM
EXTENT OF CURRENT
REVISION
KEYED NOTE MARK
MATCH LINE REFERENCE
DRAWING TITLE SYMBOLS
SEE CORRESPONDING
NUMBERED KEY NOTE ON
SHEET WHERE
REFERENCE OCCURS
DRAWING INDICATION
A B
SCALE:
A101
SIM
A101
SIM
A101
SIM
A101
SIM
A101
SIM
A1
Room Name
W-X
0A3X
1 View Name 1/8" = 1'-0"
A104
A102
A1
REF. F1 ON A201
REFERENCE LOCATION
EARTH
AGGREGATE BASE COURSE
CONCRETE
CONCRETE MASONRY UNIT
BRICK MASONRY
PRECAST CONCRETE
LIMESTONE, SANDSTONE, GRANITE
MARBLE
STEEL, STAINLESS STEEL
(LARGE SCALE)
ALUMINUM (LARGE SCALE)
OTHER METALS (LARGE
SCALE)
WOOD FRAMING -
CONTINUOUS (LARGE SCALE)
WOOD FRAMING - DISCONTINUOUS
(LARGE SCALE)
PLYWOOD
(LARGE SCALE)
FINISH WOOD (LARGE SCALE)
EIFS INSULATION BOARD
(LARGE SCALE)
SEMI-RIGID INSULATION
(LARGE SCALE)
BATT INSULATION
(LARGE SCALE)
MORTAR, SAND, FIREPROOFING,
STUCCO, GYPSUM BOARD
TERRAZZO (LARGE SCALE)
COMPOSITE BOARD
(LARGE SCALE)
ACOUSTIC TILE (LARGE SCALE)
PROTECTION BOARD
(LARGE SCALE)
CERAMIC TILE (LARGE SCALE)
GLASS (LARGE SCALE)
PLASTER CONCRETE
MASONRY, METAL SIDING
(HORIZONTAL)
GLASS BLOCK, CERAMIC
TILE
METAL SIDING (VERTICAL0
GLASS
ELEVATIONPLAN AND SECTION
THE DESIGN REFERENCE ELEVATION +0-0", AS
INDICATED ON THE DRAWINGS, CORRESPONDS TO THE
FINISH FLOOR ELEVATION OF THE GROUND FLOOR.
ESTABLISH THE ACTUAL ELEVATION WITH RESPECT TO
SITE-SPECIFIC BENCHMARKS AND CONTROL POINTS.
B.
C. ALL GRID LINES IDENTIFIED BY A LETTER DESIGNATION
ARE PARALLEL UNLESS OTHERWISE NOTED. ALL GRID
LINES IDIENTIFIED BY A NUMBER DESIGNATION ARE
PARALLEL AND ARE PERPENDICULAR TO THOSE WITH
A LETTER DESIGNATION UNLESS OTHERWISE NOTED.
THE A-SERIES DRAWINGS ESTABLISH AND
COORDINATE THE FINISHED APPEARANCE AND
EXACT LOCATION OF ALL EXPOSED ELEMENTS. THE
A-SERIES DRAWINGS TAKE PRECEDENCE FOR THE
FINISHED APPEARANCE AND EXACT LOCATION OF
ALL PARTS OF THE WORK.
A.THE FOLLOWING GENERAL NOTES APPLY TO ALL
A-SERIES DRAWINGS.
A.
B.
C.
FOR GENERAL NOTES APPLICABLE TO ALL
DRAWINGS REFER TO THE "PROJECT GENERAL
NOTES".
FOR NON A-SERIES GENERAL NOTES AND
SYMBOLS REFER TO APPLICABLE DRAWINGS.
THE A-SERIES DRAWINGS ARE A PART OF A
LARGER SET OF DRAWINGS. REVIEW AND
COORDINATE THE WORK WITH ALL ASPECTS OF
THE CONTRACT DOCUMENTS.
D.
1' -0
3'
-0
HAND RAIL
CRASH RAIL
3' -0
CHAIR RAIL
WALL PROTECTION MOUNTING HEIGHTS
WALL PROTECTION LEGEND
CHAIR RAIL
CORNER GUARD
HAND RAIL
CRASH RAIL
WALL PROTECTION
NOTE: REFER TO SPEC. SECTION 09 06 00 "SCHEDULE FOR
FINISHES" FOR FINISH - COORDINATE ALL RAIL, GUARD AND
PROTECTION WITH WALL MOUNTED ITEMS AND OPENINGS
1 HOUR FIRE BARRIER
WALL TYPE LEGEND
SEE TAG FOR TYPE
SMOKE PARTITION
2 HOUR FIRE BARRIER
SMOKE PARTITION
SMOKE BARRIER
Pl ot
Da te:
th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
FULLY SPRINKLERED
SMITHGROUP, INC.
500 Griswold Suite 1700 Detroit, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroup.com
CIVIL ENGINEER:
J-U-B ENGINEERS, Inc.
2810 West Clearwater Ave, Suite 201 Kennewick, WA 99336 T 509.783.2144 F 509.736.0790
DOOR HARDWARE:
Jenosky Consultanting, Inc.
Architectural Hardware Specifications 43422 West Oaks Drive #270 Novi, MI 48377-3300 T 248.496.7900
RADIATION SHEILDING DESIGN:
Diagnostic Physics, Inc.
P.O. Box 49587 Charlotte, NC 28277 T 704.541.9628 F 704.541.2843
SIGNAGE:
Inkspotdesign, Inc
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
T 248.960.115
320 W. Ohio Street, Suite 4W Chicago, IL 60654 T 312.337.9600 F 312.337.9876
DESIGN/BUILDER:LEVEL II DESIGN:
HDR Architecture, Inc.
440 S. Church Street, Suite 1000 Charlotte, NC 28202 Phone: (704) 338-6700
97 8654321
9/5 /20
2:
:05
P M
05AUG13
WALLA WALLA, WASHINGTON
AE0.2
ARCHITECTURAL ABBREVIATIONS AND
SYMBOLS
PT JF 4 286
JONATHAN M. WAINWRIGHT MEMORIAL
VA MEDICAL CENTER
687-400
ARCHITECTURAL ABBREVIATIONS
ARCHITECTURAL FLOOR PLAN SYMBOLS
DOOR AND INTERIOR OPENING SYMBOLS
ARCH REFLECTED CEILING PLAN SYMBOLS
ARCHITECTURAL REFERENCE SYMBOLS
ARCHITECTURAL MATERIAL INDICATIONS
ARCH GENERAL NOTES PROJECT GEN NOTES
SCALE: 3/16" = 1'-0"
WALL PROTECTION MOUNTING HEIGHTS
EE
IT IS THE INTENT OF THE DESIGN THAT ALL ITEMS SHOWN MOUNTED AT
TYPICAL HEIGHTS BE ACCESSIBLE TO PERSONS WITH DISABILITIES.
A.
B. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE TYPICAL MOUNTING HEIGHTS
AND - WHERE APPLICABLE - TYPICAL MINIMUM OR MAXIMUM CLEARANCES
AND/OR TYPICAL MOUNTING CONFIGURATIONS FOR A VARIETY OF ITEMS.
CAUTION: THIS SHEET MAY ILLUSTRATE ITEMS OR CONFIGURATIONS WHICH
DO NOT OCCUR AS PART OF THE WORK OF THIS PROJECT. REFER
TO THE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND SCHEDULES TO
DETERMINE WHICH ITEMS AND CONFIGURATIONS APPLY TO THE WORK OF
THIS PROJECT.
C. SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS OCCUR ONLY WHERE INDICATED
BY ANNOTATED SYMBOLS; BY KEY NOTES; BY NOTES ON PLANS, ELEVATIONS,
OR DETAILS; OR BY UNIQUE DIMENSIONS ON ELEVATIONS OR DETAILS.
D. MOUNTING HEIGHTS, DIMENSIONS, CLEARANCES, AND ACCESS REQUIREMENTS
FOR TOILET ACCESSORIES SHOWN ON THIS SHEET ARE BASED UPON SPECIFIC
MANUFACTURERS AND MODELS AS INDICATED BY THE "TOILET ACCESSORY
SCHEDULE." WHEN SIMILAR ACCESSORIES OF OTHER SPECIFIED, ACCEPTABLE
MANUFACTURERS (IF ANY) ARE UTILIZED, MOUNTING HEIGHTS, DIMENSIONS,
CLEARANCES, AND ACCESS REQUIREMENTS OF THE SIMILAR ACCESSORIES
MAY VARY FROM THOSE SHOWN. WHEN SIMILAR ACCESSORIES ARE UTILIZED,
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION REQUIRED
TO ACHIEVE THE SAME AESTHETIC AND FUNCTIONAL DESIGN INTENT
ILLUSTRATED BY THAT SHOWN ON THE DRAWINGS.
GENERAL MOUNTING HEIGHT NOTES
LAVATORIES ADJ TO A WALL SHALL
BE MOUNTED 18" MIN (OR GREATER
AS INDICATED ON PLANS) FROM
FACE TO ADJ WALL TO
CENTERLINE OF FIXTURE.
BOTTOM OF MIRROR
REFLECTIVE SURFACE
3'
- 4
" M
AX
2'
- 1
0" M
AX
T
O
RI
M
2'
- 5
" M
IN
C
LE
AR
MIN
8"
M
IN9"
6" MAX
WALL - MOUNTED
LAVATORY AND MIRROR
(SIDE VIEW)
WATER CLOSET FLUSH
CONTROL VALVE SHALL BE
LOCATED ON THE WIDE SIDE
OF THE FIXTURE.
AC
CE
SS
IB
LE
1'
- 5
1'
- 3
" T
YP
WATER CLOSET
(SIDE VIEW)
TO
F
LU
SH
C
ON
TR
OL
" M
AX
LI
NE
O F
W
AL
L
OR
F
AC
E
OF
U
RI
NA
L
SC
RE
EN
/1
2'
- 0
" T
YP
AC
CE
SS
IB
LE
2'
- 0
1'
- 5
TO
F
LU
SH
C
ON
TR
OL
A T
AC
CE
SS
IB
LE
" M
AX
URINAL - ELEVATION
MIN
1' - 3"
5" MAX
3'
- 0
" M
AX
2'
- 9
" M
IN
2'
- 3
" M
INMIN
8"
MIN
11"
M
IN9"
DRINKING FOUNTAIN
OR WATER COOLER
(SIDE VIEW)
FINISH FACE
OF WALL
FINISH FACE OF WALL
TOILET SEAT
COVER AS
SPECIFIED
ACCESSIBLE W.C.
TOILET
ACCESSORIES
(AS APPLIES)
A B
C
FIXTURE ELEVATION SIDE ELEVATION
SIDE ELEVATIONTYPICAL ACCESSIBLE TOILET PLAN
3'
- 6
1'
- 0
8"
A
C B
6" 3' - 0"
1' - 6" 3' - 6"
5' - 0" CLEAR
1'
- 6
3'
- 4
2'
- 9
2' - 0"
1'
- 9
3'
- 4
MIN
1' - 3"
(T O
P O
F
SE
AT
TYPICAL FIXTURE CLEARANCES TYPICAL ACCESSIBLE RESTROOM CONFIGURATION DIAGRAMS
NURSE CALL
DEVICE
4'
- 0
" M
AX
F
OR
C
ON
TR
OL
S
FO
R
CO
NT
RO
LS
3'
- 2
" M
IN
GR
A B
B
AR
2'
- 9
" T
YP
2'
- 5
TOP
OF
UNIT
(RECESSED)
2'
- 5
TOP
OF
UNIT
TOILET TISSUE DISPENSERS
(CENTERED IN
PARTITION) (SURFACE)
1'
- 8
TOP
OF
UNIT
1'
- 3
" M
IN
3'
- 4
" T
YP
DISPENSER
2'
- 7
TOP
OF
UNIT
SEAT - COVER
DISPENSER
SANITARY
NAPKIN
DISPOSAL
(RECESSED - SHOWN)
NO
N
- A
CC
ES
SI
BL
E
5'
- 0
TOP
OF
UNIT
3'
- 8
TOP
OF
UNIT
2'
- 6
TOP
OF
UNIT
COMBINATION TOILET COMPARTMENT ACCESSORIES
PARTITION MOUNTED OR RECESSED SANITARY NAPKIN
DISPOSAL / TOILET
TISSUE DISPENSER
4'
- 0
" M
AX
F
OR
C
ON
TR
OL
S
FO
R
CO
NT
RO
LS
3'
- 2
" M
IN
3'
- 4
DISPENSER
RE
CO
M
EN
DE
D
" T
O
TOP
OF
UNIT
3'
- 0
" M
AX
2'
- 6
" M
IN
TOP
OF
UNIT
RE
CO
M
EN
DE
D
5'
- 2
TOP
OF
UNIT
PAPER TOWEL DISPENSERS WASTE RECEPTACLES
(RECESSED) (SURFACE MTD)
PAPER TOWEL DISPENSER / WASTE RECEPTACLES
(RECESSED
& FULLY
RECESSED)
(RECESSED) (RECESSED)
3'
- 4
DISPENSER
3'
- 4
COIN
SLOT
RE
CO
M
EN
DE
D
3'
- 8
PUSH
BUTTON
RE
CO
M
EN
DE
D
3'
- 2
M
AX
A
BO
VE
L
AV
AT
OR
Y
3'
- 4
M
AX
O
TH
ER
L
OC
AT
IO
NS
(T O
BO
TT
OM
O
F
RE
FL
EC
TI
VE
SU
RF
AC
E)
W / S
HE
LF
SANITARY
NAPKIN / TAMPON
VENDORS
(RECESSED
&SURFACE)
SOAP
DISPENSERS
HAND
DRYER
(SURFACE)
ALL FRAMED
MIRRORS
(SURFACE)
2'
- 9
TYPICAL TOILET COMPARTMENT ACCESSORY MOUNTING HEIGHTS TYPICAL LAVATORY AREA ACCESSORY MOUNTING HEIGHTS
SPECIMEN PASS-
THRU CABINET
4'
- 2
" M
AX
F
OR
C
ON
TR
OL
S
FO
R
CO
NT
RO
LS
3'
- 4
/2
" M
IN
6'
- 4
SHOWER
CURTAIN
ROD
3'
- 4
SURFACE MOUNTED
SHOWER STALL
SOAP DISH
5'
- 0
NO
N
- A
CC
ES
SI
BL
E) 4'
- 2
CLOTHES
HOOK AND
BUMPER
FOLDING
UTILITY SHELF
PARTITION
1'
- 5
TOP
OF
UNIT
6'
- 0
TOP
OF
UNIT
5'
- 0
TOP
OF
UNIT
MOP & BROOM
HOLDER
SHELF WITH
MOP & BROOM
HOLDER &
HOOKS
SHELF WITH
MOP & BROOM
HOLDER &
HOOKS
5'
- 6
TOP
OF
UNIT
6'
- 6
3'
- 4
FIXED
SHOWER
HEAD
SINGLE LEVER
SHOWER MIXING
VALVE
TYPICAL SHOWER AREA AND MISCELLANEOUS ACCESSORY MOUNTING HEIGHTS
SPECIAL PURPOSE OUTLETS /
NURSE CALL STATION -
2'
- 6
"9'
- 0
CEILING MOUNTED TOILET
PARTITIONS
AE0.3
1'
- 0
3'
- 6
1' - 6"
GRAB BARS AT ALL PUBLIC &
PATIENT TOILETS
2'
- 8
SE
E
PG
-1
8-
F
OR
M
IN
IM
UM
S
TA
ND
AR
D 8'
- 7
NOTES:
A/E SHALL LOCATE GRAB BARS AND TOILET ACCESSORIES IN ACCORDANCE WITH
CHAPTER 6 OF THE ADA-ABA ACCESSIBILITY STANDARD.
VA BARRIER FREE DESIGN GUIDE PG-18-13 SPECIFIES LARGER WHEELCHAIR
ACCESSIBLE STALLS AND FRONT TRANSFER (AMBULATORY ACCESSIBLE) STALLS
THAN REQUIRED BY ADA-ABAAS. GRAB BARS ARE REQUIRED IN ALL TOILET
STALLS, NOT JUST ACCESSIBLE STALLS.
AI8.1.1
E1
METAL TOILET COMPARTMENT SUPPORT DETAIL
METAL TOILET COMPARTMENT
PARTITION SYSTEM
CEILING SYSTEM
CONTINUOUS L3x2x1/4 FOR
CUMULATIVE STALL WIDTH
CONTINUOUS C8x11.5 FOR
CUMULATIVE STALL WIDTH
3/4"� ROD @3'-0" OC
C3/4" @12" OC
C2 @2'-6" OC x
5'-0" LONG
TYPICAL TOILET PARTITION LAYOUT
Pl ot
Da te:
th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
FULLY SPRINKLERED
SMITHGROUP, INC.
500 Griswold Suite 1700 Detroit, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroup.com
CIVIL ENGINEER:
J-U-B ENGINEERS, Inc.
2810 West Clearwater Ave, Suite 201 Kennewick, WA 99336 T 509.783.2144 F 509.736.0790
DOOR HARDWARE:
Jenosky Consultanting, Inc.
Architectural Hardware Specifications 43422 West Oaks Drive #270 Novi, MI 48377-3300 T 248.496.7900
RADIATION SHEILDING DESIGN:
Diagnostic Physics, Inc.
P.O. Box 49587 Charlotte, NC 28277 T 704.541.9628 F 704.541.2843
SIGNAGE:
Inkspotdesign, Inc
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
T 248.960.115
320 W. Ohio Street, Suite 4W Chicago, IL 60654 T 312.337.9600 F 312.337.9876
DESIGN/BUILDER:LEVEL II DESIGN:
HDR Architecture, Inc.
440 S. Church Street, Suite 1000 Charlotte, NC 28202 Phone: (704) 338-6700
97 8654321
9/5 /20
2:
:13
P M
05AUG13
WALLA WALLA, WASHINGTON
AE0.3
TYPICAL TOILET ROOM MOUNTING
HEIGHTS AND STALL CONFIGURATION
DIAGRAMS
PT JF 5 286
JONATHAN M. WAINWRIGHT MEMORIAL
VA MEDICAL CENTER
687-400
ARCHITECTURAL DIMENSIONING CONVENTIONS
D.
5.
DIMENSION, WHEN OCCURS
ALIGN
B.
C.
B.
A.
4.
3.
A.
F.
E.
D.
1.
2. E.
C.
EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE
WORK AT THE "APPROXIMATE LOCATION SHOWN,"
DO NOT SCALE DRAWINGS FOR DIMENSIONAL
INFORMATION.
ALL ELEMENTS OF THE DRAWINGS MAY NOT BE
DRAWN TO EXACT SCALE. ALL DIMENSIONS
REQUIRED ARE SHOWN (OR MAY BE DERIVED
FROM THOSE SHOWN OR NOTED) ON THE FLOOR
PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS,
SCHEDULES, CONFIGURATION DETAILS, AND
SPECIFICATIONS. SEE THE NOTES BELOW AND
SYMBOLS ON SHEET A0.2 FOR DIMENSIONING
CONVENTIONS USED ON THIS PROJECT.
EXCEPT WHERE SPECIFICALLY NOTED TO THE
CONTRARY, ALL DIMENSIONS SHOWN ON THE
ARCHITECTURAL DRAWINGS CONFORM TO THE
FOLLOWING CONVENTIONS:
DIMENSIONS UTILIZING THE "CENTERLINE" SYMBOL
ARE MEASURED TO:
STRUCTURAL OR DIMENSIONAL GRID LINES.
CENTERLINE OF CONCRETE OR CONC
MASONRY UNIT WALLS (EXCLUSIVE OF
FURRING OR APPLIED FINISHES HAVING
THICKNESS). REFER TO THE ARCH PLANS
AND SECTIONS, THE STRUCT DRAWINGS,
OR PARTITION SCHEDULE TO DETERMINE
THE THICKNESS OF CONCRETE OR CONC
MASONRY UNIT WALLS.
CENTERLINE OF PARTITION ASSEMBLY
(EXCLUSIVE OF ANY APPLIED FINISHES
HAVING THICKNESS WHICH MAY BE
ADDED TO SUCH WALLS) AT PARTITIONS
FRAMED WITH METAL STUDS. REFER TO
"PARTITION SCHEDULE" TO DETERMINE
THICKNESS OF EACH PARTITION TYPE.
CENTERLINE OF DOOR, WINDOW, OR LOUVER
OPENING.
CENTERLINE OF EQUIPMENT OR
FURNISHING.
CENTERLINE OF OTHER FEATURES AS
INDICATED.
REFER TO SHEET A0.2 FOR SYMBOL USED
TO INDICATE CENTERLINE DIMENSION.
DIMENSIONS UTILIZING THE "FACE OF"
SYMBOL ARE MEASURED TO:
FACE OF CONCRETE OR CONC MASONRY
UNIT WALL (EXCLUSIVE OF APPLIED
FINISHES HAVING THICKNESS OR FURRING
WHICH MAY BE ADDED TO THE FACE OF
SUCH WALLS).
FACE OF PARTITION ASSEMBLY
(EXCLUSIVE OF ANY APPLIED FINISHES
HAVING THICKNESS WHICH MAY BE
ADDED TO SUCH WALL) AS DEFINED
BY THE PARTITION SCHEDULE.
UNLESS NOTED AS A "FACE OF
FINISH" OR "CLEAR" DIMENSION (SEE
NOTE 'E' BELOW), DIMENSIONS ARE
NOT MEASURED TO THE FACE OF
APPLIED FINISH. REFER TO THE
"PARTITION SCHEDULE" TO DETERMINE
THE THICKNESS OF EACH PARTITION
TYPE.
INSIDE EDGE OF FINISHED DOOR
OPENING. REFER TO THE "DOOR
SCHEDULE" FOR ADDITIONAL
DIMENSIONAL INFORMATION.
DIMENSION OR WORK POINT AS INDICATED ON RELATED
ARCH DETAIL PLAN, SECTION, ELEVATION, LAYOUT OR
CONFIGURATION DETAIL, OR CONSTRUCTION DETAIL.
REFER TO SHEET A0.2 FOR SYMBOL USED
TO INDICATE "FACE OF" DIMENSION.WHERE "FACE OF FINISH" OR "CLEAR" DIMENSIONS
ARE SPECIFICALLY NOTED, THE DIM IS MEASURED
TO:
FINISH FACES AT THE MOST NARROW
OR CONSTRICTED POINTS OF SECTION
WHERE DIMENSION IS SHOWN, WHEN
THE DIMENSION OCCURS ACROSS AN
OPEN SPACE. THIS CASE, A "FACE
OF FINISH" DIMENSION IS EQUIVALENT
TO A "CLEAR" DIMENSION.FINISH FACES AT THE WIDEST OR MOST
EXPANSIVE POINTS OF THE SECTION THE
DIMENSION IS SHOWN WHEN THE DIMENSION
OCCURS ACROSS AN OBJECT OR GROUP OF
OBJECTS.
WHERE "EQUAL" DIMENSIONS ARE USED
ON REFLECTED CEILING PLANS TO
LOCATE CEILING GRID WORK POINTS,
MEASURE DIMENSIONS TO:
EDGE OF THE INDICATED CEILING AT
THE FACE OF THE ADJACENT APPLIED
FINISH MEASURED AT THE PLANE OF
THE CEILING.
CAUTION: DUE TO THE POSSIBLE
APPLICATION OF APPLIED FINISHES -
THICKNESS OF WHICH MAY VARY
BETWEEN FLOOR AND CEILING AND IS
NOT ACCOUNTED FOR (EXCEPT AS
INDICATED BY "FOF" OR "CLEAR") BY
THE DIMENSION SHOWN ON THE FLOOR
PLANS - THE CONTRACTOR MUST
ADJUST, AS NECESSARY, THE FLOOR
PLAN DIMENSIONS TO REFLECT THE
ACTUAL DIMENSIONS FOUND AT PLANE
OF THE CEILING.
WHERE DIMENSIONS ARE NOT PROVIDED ON
FLOOR PLANS TO LOCATE DOOR OPENINGS,
APPLY THE FOLLOWING RULES, IN ORDER, TO
DETERMINE THE LOCATION OF DOOR OPENINGS:
DOOR OPENINGS MAY BE
DIMENSIONED ON DRAWINGS OTHER
THAN THE FLOOR PLANS. REFER TO
THE SECTIONS, ELEVATIONS, DETAILS,
AND DOOR SCHEDULE NOTES FOR
ADDITIONAL DIMENSIONAL
INFORMATION.
WHERE THE HINGE-SIDE OF A DOOR IS
SHOWN ADJACENT TO A WALL - OR WALLS
- PERPENDICULAR TO THE WALL IN WHICH
THE DOOR OPENING OCCURS:
AT DOORS OCCURRING IN METAL FRAMED
GYPSUM BOARD PARTITIONS, LOCATE THE
HINGE-SIDE OF THE DOOR FINISHED
OPENING 4 INCHES FROM THE FACE
(EXCLUSIVE OF APPLIED FINISHES) OF THE
THE CLOSEST PERPENDICULAR WALL OR
PARTITION ASSEMBLY.
AT DOORS OCCURRING IN WALLS OF CONC
MASONRY UNIT CONSTRUCTION, LOCATE
THE HINGE-SIDE OF THE DOOR FINISHED
OPENING 10 INCHES FROM THE FACE
(EXCLUSIVE OF APPLIED FINISHES) OF THE
THE CLOSEST PERPENDICULAR WALL OR
PARTITION ASSEMBLY.
WHERE DOOR OCCURS NOT ADJACENT TO A
PERPENDICULAR WALL AND EITHER "DIM E"
OR "DIM F" IS 16'-0" OR LESS, LOCATE
DOOR UTILIZING THE FOLLOWING MINIMUM
DIMENSIONS:
DIMENSION A = 18 INCHES MIN
DIMENSION B = 12 INCHES MIN
DIMENSION C = DOOR WIDTH + 2
INCHES MINIMUM
DIMENSION D = 4 INCHES MIN AT
METAL FRAMED GYP BD PARTITIONS
OR - EVEN MULTIPLE OF 1/2 CMU
MODULE PLUS 2 INCHES AT CONC
MASONRY UNIT WALLS
DIMENSIONS E AND F = AS SHOWN ON
PLANS
DIMENSION G = 36 INCHES MIN
DIMENSION H = 60 INCHES MIN
IF SPACE ALLOWS, CENTER DOOR IN
WALL SHOWN ON THE DRAWINGS SO
THAT EITHER "DIM A" EQUALS "DIM C"
OR "DIM B" EQUALS "DIM D".
IF "DIM E" IN DIAGRAMS BELOW IS LESS
THAN THE SUM OF 2 TIMES THE DOOR
WIDTH PLUS 20 INCHES, LOCATE DOOR
SO THAT MINIMUMS STATED BY NOTE
NO 4C ABOVE FOR "DIM A", "DIM B,"
AND "DIM D" ARE MET - MAXIMIZING
"DIM A" AND MINIMIZING "DIM D" TO
THE EXTENT POSSIBLE.
WHERE DOOR IS SHOWN LOCATED IN A
LARGE EXPANSE OF OPEN WALL ("DIM
E" AND "DIM F" IN DIAGRAM BELOW
BOTH EXCEED 16'-0"), PLACE DOOR
AT APPROXIMATE LOCATION SHOWN ON
THE PLANS. WHERE DOOR OCCURS IN
CMU WALL, PLACE DOOR AT
APPROXIMATE LOCATION SHOWN WHILE
MINIMIZING "CUT" OR PARTIAL CMU
MODULES ADJACENT TO THE JAMBS.
WHERE WALLS AND/OR PARTITIONS OF
UNEQUAL THICKNESS ABUT, ALIGN EXPOSED
FACES, UNLESS OTHERWISE NOTED.
3. NOTE NO 3 CONTINUED:
MEASURED AT CLG PLANE
"EQUAL" DIM AT CEILING
MEASURED TO FACE OF PTN
TYPICAL DIM ON CEILING PLAN
4"
4"
10"
10"
DIM E > 16'-0"
DIM F > 16'-0"
E
A
E
A D
B D B
E A C
F
B D
G
H
- CONTINUED AT TOP OF NEXT COLUMN
NOTE NO 4 CONTINUED:4.
- CONTINUED AT TOP OF NEXT COLUMN - CONTINUED AT TOP OF NEXT COLUMN- CONTINUED AT TOP OF NEXT COLUMN - CONTINUED AT TOP OF NEXT COLUMN
3. NOTE NO 3 CONTINUED: 3. NOTE NO 3 CONTINUED: NOTE NO 4 CONTINUED:4.
- CONTINUED AT TOP OF NEXT COLUMN
NOTE NO 4 CONTINUED:4.
GENERAL MOUNTING HEIGHT NOTES
TYPICAL MOUNTING HEIGHTS AND CLEARANCES
CORNER GUARD / PROTECTION WALL PANELS TYPICAL MOUNTING HEIGHTS AND CONFIGURATION DIAGRAMS
CLOCK OR
CLOCK OUTLET
LIGHT SWITCH
& DIMMER
DUPLEX
OUTLET
DUPLEX
OUTLET
DESK
INTERCOM
OUTLET
INTERCOM
STATION
TELECOMM
OUTLET
THERMOSTAT SPECIAL
PURPOSE
OUTLETS
SPECIAL
PURPOSE
OUTLETS / NURSE
CALL STATION
JUNCTION BOX WALL-MTD
TELEPHONE
OUTLET
CARD READER,
LOCAL ALARM, OR
ARMING STATION
AUDIBLE
AND/OR VISUAL
FIRE ALARM
SECURITY
STROBE LIGHT
(BLUE LIGHT)
FIREMAN'S
TELEPHONE
JACK
REQD SIGNAGE
AT MEN'S TOILET
ENTRY DOOR
REQD SIGNAGE AT
WOMEN'S TOILET
ENTRY DOOR
REQD SIGNAGE AT
UNISEX TOILET
ENTRY DOOR
MEDICAL
GAS ALARM
PANEL
FEC OR
FHV
CABINET
ELECTRICAL
PANELBOARD
(FLUSH MTD)
ELECTRICAL
PANELBOARD
(SURFACE MTD)
COAT
HOOKS
(WALL-MTD)
COAT
HOOK
(DOOR-MTD)
CHALKBOARD,
TACKBOARD, OR DRY
MARKER BOARD
WALL-MOUNTED
EXIT SIGN AT
EXIT DOOR
EQUIPMENT, PANEL
BOARD,
CABINET, OR
SIMILAR FEATURE
TYPE NO 1
(SHOWN), 4" X 4"
STAINLESS STEEL
CORNER GUARD
WALL PROTECTION
PANELS
TERMINATE INTO
WALL GUARDS
DOOR FRAME OR CASED
OPENING FRAME
OUTLET OR SIMILAR
IT IS THE INTENT OF THE DESIGN THAT ALL
ITEMS SHOWN MOUNTED AT TYPICAL HEIGHTS
BE ACCESSIBLE TO PERSONS WITH DISABILITIES.
THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE
TYPICAL MOUNTING HEIGHTS AND - WHERE
APPLICABLE - TYPICAL MINIMUM OR MAXIMUM
CLEARANCES AND/OR TYPICAL MOUNTING
CONFIGURATIONS FOR A VARIETY OF ITEMS.
CAUTION: THIS SHEET MAY ILLUSTRATE ITEMS
OR CONFIGURATIONS WHICH DO NOT OCCUR AS
PART OF THE WORK OF THIS PROJECT. REFER
TO THE PLANS, ELEVATIONS, SECTIONS,
DETAILS, AND SCHEDULES TO DETERMINE WHICH
ITEMS AND CONFIGURATIONS APPLY TO THE
WORK OF THIS PROJECT.
B.
A.
C.
D.
E.
F.
G.
THE MOUNTING HEIGHTS, CLEARANCES, AND
CONFIGURATIONS SHOWN ON THIS SHEET ARE
TYPICAL AND SHALL APPLY TO ALL INSTANCES
OF THE ITEM (OR GROUP OF ITEMS) SHOWN
UNLESS SPECIFICALLY NOTED OR DIMENSIONED
OTHERWISE.
SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS
OCCUR ONLY WHERE INDICATED BY ANNOTATED
SYMBOLS; BY KEY NOTES; BY NOTES ON
PLANS, ELEVATIONS, OR DETAILS; OR BY UNIQUE
DIMENSIONS ON ELEVATIONS OR DETAILS.
FOR ADDITIONAL INFORMATION REGARDING THE
PRECEDENCE OF DRAWINGS FOR DETERMINING
THE EXACT LOCATION OF EACH EXPOSED PART
OF THE WORK, REFER TO THE "ARCHITECTURAL
GENERAL NOTES" ON SHEET A0.1 AND TO THE
"TYPICAL RULES FOR DETERMINING MOUNTING
HEIGHTS AND LOCATIONS" ON SHEET A0.4.
TYPICAL MOUNTING HEIGHTS FOR ADDITIONAL
ITEMS NOT SHOWN ON THIS SHEET MAY BE
ILLUSTRATED BY OTHER SHEETS. REFER TO
THE "INDEX OF DRAWINGS" FOR ADDITIONAL
INFORMATION.
MOUNTING CONFIGURATION DIAGRAMS ARE
ELEVATIONS WHICH ILLUSTRATE TYPICAL
RULES GOVERNING THE RELATIONSHIPS
BETWEEN, AND PLACEMENT OF, ITEMS WHICH
OCCUR IN GROUPS OF RELATED ITEMS OR IN
CLOSE PROXIMITY TO OTHER PARTS OF THE
WORK (SUCH AS SWITCHES AND DOOR
FRAMES). UNLESS OTHER MOUNTING
CONFIGURATIONS ARE SPECIFICALLY NOTED,
DIMENSIONED, OR ELEVATED, THE TYPICAL
RELATIONSHIPS, ARRANGEMENTS, AND THE
TYPICAL CONFIGURATION DIAGRAMS APPLY
THROUGHOUT THE WORK OF THIS PROJECT.
TYPICAL MOUNTING CONFIGURATIONS FOR
ADDITIONAL GROUPING NOT SHOWN ON THIS
MAY BE SHOWN ON OTHER SHEETS. REFER
TO THE "INDEX OF DRAWINGS" FOR
ADDITIONAL INFORMATION.
H.
DISCONNECT
SWITCH &
MOTOR
STARTER
TACTILE
EXIT SIGN -
REFER TO
TO NOTE "J"
CEILING LINE
EMERGENCY
STROBE OR
LIGHT AND/OR
NURSE CALL
LIGHT
RACEWAY
EXIT
EXIT
CE
NT
ER
O
N M
AS
ON
RY
U
NI
T
7'
- 0
4'- 0"
M
AX
H
IG
H
RE
AC
H
3'- 0"
M
IN
F
OR
C
ON
TR
OL
S
1'- 3"
M
IN
L
OW
R
EA
CH
1'
- 6
M
AS
ON
RY
U
NI
T W
HE
RE
A
PP
LI
CA
BL
E
4'
- 0
OR
) C
EN
TE
R
IN
7'
- 2
7'
- 2
7'
- 2
4'
- 0
5'
- 6
EQ EQ 1' - 0"
4'
- 0
" M
AX
H
IG
H
RE
AC
H
3'
- 0
" M
IN
F
OR
C
ON
TR
OL
S
1'
- 3
" M
IN
L
OW
R
EA
CH
4'
- 6
5'
- 0
EQ EQ 1' - 0"
5'
- 0
EQ EQ 1' - 0"
5'
- 0
1' - 0"
4'
- 0
1'
- 0
3'
- 6
6'
- 0
2'
- 3
" M
AX
6'
- 0
6"
5'
- 9
4'
- 0
EQ EQ
6'
- 0
7'
- 2
4" EQ EQ
2"
1'
- 0
" O R
GR
EA
TE
R
M
OU
NT
O
N
ST
RI
KE
S
ID
E
AL
IG
N W
IT
H
TO
P
OF
A
DJ
AC
EN
T
FR
AM
E W
HE
N
DI
M
A
BO
VE
D
OO
R
HE
AD
2"
IS
2" O
R
GR
EA
TE
R
LO
CA
TE
" A
BO
VE
D
OO
R
FR
AM
E W
HE
N
DI
M
A
BO
VE
D
OO
R
HE
AD
2'
- 1
0" U
ON
1'
- 4
" U
ON
6" 3'
- 6
TY
PE
WALL
PROTECTION
PANELS
2'
- 1
0"
ADA
DOOR
OPERATOR
PROVIDE SST THREADED
ROD AND HARDWARE FOR
EXIT SIGN WHERE NO
SOFFIT IS PROVIDED
REQD SIGNAGE
AT MEN'S TOILET
ENTRY DOOR
REQD SIGNAGE AT
WOMEN'S TOILET
ENTRY DOOR
REQD SIGNAGE AT
UNISEX TOILET
ENTRY DOOR
MEDICAL
GAS ALARM
PANEL
FEC OR
FHV
CABINET
ELECTRICAL
PANELBOARD
(FLUSH MTD)
ELECTRICAL
PANELBOARD
(SURFACE MTD)
COAT
HOOKS
(WALL-MTD)
COAT
HOOK
(DOOR-MTD)
CHALKBOARD,
TACKBOARD, OR DRY
MARKER BOARD
WALL-MOUNTED
EXIT SIGN AT
EXIT DOOR
TACTILE
EXIT SIGN -
REFER TO
TO NOTE "J"
CEILING LINE
EXIT
EXIT
3'
- 1
0" M
AX
H
IG
H
RE
AC
H
2'
- 1
0" M
IN
F
OR
C
ON
TR
OL
S
1'
- 1
" M
IN
L
OW
R
EA
CH
4'-
CE
NT
ER
ED
O
N M
AS
ON
RY
U
NI
T)
4'-
CE
NT
ER
ED
O
N M
AS
ON
RY
U
NI
T)
4'-
CE
NT
ER
ED
O
N M
AS
ON
RY
U
NI
T)
1' - 0"
3'
- 4
5'
- 1
0"
2'
- 1
" M
AX
5'
- 1
0"
5'
- 6
CE
NT
ER
ED
O
N M
AS
ON
RY
U
NI
T)
3'
- 6
" C L
OF
M
AS
ON
RY
U
NI
T
W
IT
H
AD
JA
CE
NT
H
OO
KS
5'
- 6
" A
LI
GN
M
AS
ON
RY
JO
IN
T 6'
- 6 " A
LI
GN
W
TACTILE
EXIT SIGN -
REFER TO
TO NOTE "J"
4" EQ EQ
2"
1'
- 0
" O R
GR
EA
TE
R
M
OU
NT
O
N
ST
RI
KE
S
ID
E
AL
IG
N
W / M
AS
ON
RY
JO
IN
T
IS
2" O
R
GR
EA
TE
R
LO
CA
TE
" A
BO
VE
D
OO
R
FR
AM
E W
HE
N
DI
M
A
BO
VE
D
OO
R
HE
AD
PROVIDE SST THREADED
ROD AND HARDWARE FOR
EXIT SIGN WHERE NO
SOFFIT IS PROVIDED
M
AS
ON
RY
JO
IN
T 3'
- 6 " A
LI
GN
W
M
AS
ON
RY
U
NI
T 3'
- 6 " C
EN
TE
R
ON
CORNER GUARD / PROTECTION WALL PANELS TYPICAL MOUNTING HEIGHTS AND CONFIGURATION DIAGRAMS AT MASONRY CONSTRUCTION
MANUAL FIRE
ALARM PULL
STATION
M
AS
ON
RY
U
NI
T 4'
- 0 " C
EN
TE
R
ON
M
AS
ON
RY
1'
- 8
M
AS
ON
RY
1'
- 8
M
AS
ON
RY
1'
- 8
M
AS
ON
RY
1'
- 8
M
AS
ON
RY
1'
- 8
CE
NT
ER
O
N M
AS
ON
RY
U
NI
T
7'
- 0
CE
NT
ER
O
N M
AS
ON
RY
U
NI
T
7'
- 0
CE
NT
ER
O
N M
AS
ON
RY
U
NI
T
7'
- 0
ALIGN IN MASONRY UNIT
HORIZONTALLY
CENTER IN
MASONRY
UNIT
CENTER IN
MASONRY
UNIT
CENTER IN
MASONRY
UNIT
CENTER IN
MASONRY
UNIT
CENTER IN
MASONRY
UNIT
CENTER IN
MASONRY
UNIT
CENTER IN
MASONRY
UNIT (TYP.)
CENTER ASSEMBLY
W/I MASONRY UNIT
NOTE:
- CENTER ALL DEVICES HORIZONTALLY WITHIN A MASONRY UNIT WHERE MOUNTED TO MASONRY CONSTRUCTION
- USE MASONRY ALIGNED DESIGNATIONS WHEN MOUNTING TO MASONRY CONSTRUCTION
WALL MOUNTED
FLAT PANEL MONITOR
Pl ot
Da te:
th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e…
This is the start of the file's text. The full file is on GovTribe.