436-23-132 Endo Suite Finish Enhancement ISSUED 12.22.2023.pdf

PDF 2 MB Posted

Attached to
Z2DA--Endo Suite Finish (436-23-132)
Solicitation number
36C25924Q0099
Issued by

About this file

This solicitation is for endoscopy suite finish enhancement services at the Montana VA Health Care System. The scope of work includes replacing approximately 1,200 square feet of sheet vinyl flooring with epoxy coating on walls and anti-skid epoxy/resinous flooring including a 6-inch integral base. One procedure room will receive a new flushing faucet. The contractor must follow infection control and safety requirements, phase construction to minimize impacts, and complete work within 30 days of the notice to proceed. The contractor will be responsible for site verification, submittals, scheduling, project management and ensuring compliance with all applicable construction standards.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 View Name 1/8" = 1'-0"

SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE

ELEVATION CALLOUT EXAMPLE

DETAIL CALLOUT EXAMPLE

SECTION CALLOUT EXAMPLE

SECTION, DETAIL, OR ELEVATION

SYMBOL IDENTIFIERS

DETAIL NAME

LETTER OR NUMBER DESIGNATOR

DRAWING SEQUENCE NUMBER

INDICATES WHERE TITLE IS

LOCATED

ONE OR TWO CHARACTER

DISCIPLINE DESIGNATOR

(MAY NOT BE PRESENT IF

CALLOUT AND TITLE ARE ON

DRAWINGS WITHIN THE SAME

DISCIPLINE)

A A101

AE101

AE101

DETAIL NUMBER

ON SHEET

SHEET NUMBER

DETAIL NUMBER

ON SHEET

SHEET NUMBER

02 \ A-1.04

2'-0" 2'-2"

2' -1

0" M

AX

0'-10"

MAX.

2'-6"

4' -0

4' -6

M

AX

0' -9

M

IN

2' -3

M

IN

. 2' -5

M

IN

.3' -4

M

AX

1'-5"

MIN.

2' -6

M

IN

4'-0"

MIN.

19"

MAX.

MIRROR

CLEAR

FLOOR

SPACE

0'-6"

MAX.

0'-8"

MIN.

1'-5"

MIN.

MIRROR

2' -1

0" M

AX

2' -3

M

IN

0' -9

M

IN

0'-6"

MAX.

0'-8"

MIN.

1' -5

" T O

'-7

1'-0"

MAX.

2' -9

" T O

'-0

3'-6"

MIN.

3'-0"

TOILET PAPER

1'-6"

TYP.

1'-0"1'-0"

3'-0"

MIN.

2' -9

" T O

'-0

1' -5

" T O

'-7

ACCESSIBLE TOILET WITH GRAB BAR ACCESSIBLE TOILET WITH GRAB BAR

1'-6" MIN.

2'-0" PREFERRED.

5' -0

" M

IN

PULL SIDE PUSH SIDE

(A) FRONT APPROACHES - SWING DOORS

3' -6

" M

IN

4'-0" MIN. IF

DOOR HAS

BOTH

LATCH AND

CLOSER

1'-0"

MIN.

* IF DOOR HAS BOTH A

CLOSER AND LATCH

W

ID

TH

CLR. LENGTH

IF WIDTH IS 5', CLR. LENGTH IS 3'-0" MIN.

IF WIDTH IS 4'-6", CLR. LENGTH IS 3'-6" MIN.

3' -6

M

IN

4'-6"

MIN.

4'-0" MAX. IF DOOR

HAS BOTH A

CLOSER AND

LATCH.

(B) HINGE-SIDE APPROACHES - SWING DOORS

4' -0

" M

IN

2'-0"

MIN.

4'-6" MIN. IF DOOR HAS CLOSER

(C) LATCH-SIDE APPROACHES - SWING DOORS

2'-0"

MIN.

3' -6

4'-0" MIN. IF

DOOR HAS

BOTH A

LATCH AND

CLOSER

(A) CLEAR FLOOR SPACE, PARALLEL APPROACH (B) HIGH AND LOW SIDE REACH (C) MAXIMUM SIDE REACH

OVER OBSTRUCTIONS

LAVATORY CLEARANCES DRINKING FOUNTAIN SPOUT HEIGHT

AND KNEE CLEARANCES

ROLL-IN SHOWER WITH FOLDING SEAT

3' -0

1' -4

M

IN

2'-0"

MIN.

3'-0"

MIN.

DRAIN

NAPKIN DISPOSAL

FORT HARRISON VA MEDICAL SYSTEM

VAMC PROJECT # 436-23-132

ENDOSCOPY SUITE FINISH ENHANCEMENT

SHEET LIST

G-0.00 COVER SHEET

G-1.00 AREA OF WORK, PROPOSED ICRA PLAN

A-1.03 FINISH AND WALL PROTECTION PLANS

E-1.01 ELECTRICAL AND ELECTRICAL ROOF PLANS

P-1.01 PLUMBING PLAN

T-1.01 TELECOMMUNICATIONS AND SECURITY PLAN

GENERAL NOTES

ABBREVIATIONS

& AND

@ AT

AB ANCHOR BOLT

ACFL ACCESS FLOOR

ACOUS ACOUSTICAL

AD AREA DRAIN

ADJ ADJUSTABLE

ADJ ADJACENT

ADMIN ADMINISTRATION

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

AP ACCESS PANEL

APROX APPROXIMATE

ARCH ARCHITECTURAL

AT ACOUSTICAL CEILING TILE

AUTO AUTOMATIC

AWT ACOUSTICAL WALL TREATMENT

B

BD BOARD

BFE BOTTOM FOOTING ELEVATION

BG BUMPER GUARD

BKT BRACKET

BLDG BUILDING

BM BEAM

BOT BOTTOM

BP BRICK PAVING

BR BRICK

BRG BEARING

BSMT BASEMENT

C

C CHANNEL

CAB CABINET

CANTL CANTILEVER

CAP CAPACITY

CAT CATEGORY

CCTV CLOSED CIRCUIT TELEVISION

CD COILING DOOR

CG COILING GRILLE

CG COILING GUARD

CH COAT HOOK

CJT CONTROL JOINT

CL CENTER LINE

CL CLASS

CLG CEILING

CLR CLEAR

CM CONSTRUCTION MANAGER

CMU CONCRETE MASONRY UNIT

CO CASED OPENING

COL COLUMN

CONC CONCRETE

CONF CONFERENCE

CONN CONNECT/-ED/-ION

CONST CONSTRUCTION

CONT CONTINUE/CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

CORR CORRIDOR

CP CARPET

CPT CARPET MODULE TILE

CR-1 CHAIR RAIL

CR-2 CRASH RAIL

CT CERAMIC TILE

CTR CENTER

CW CURTAIN WALL

CW COLD WATER

CYL CYLINDER

D

D DEPTH OR DEEP

DEMO DEMOLITION

DEPR DEPRESSIONDBL DOUBLE

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIFF DIFFUSER

DIM DIMENSION

DISP DISPENSER

DIST DISTRIBUTION

DIV DIVISION

DN DOWN

DP DATA PROCESSING

DR DOOR

DS DOWNSPOUT

DWG DRAWING

E

EC ELECTRICAL CABINET

EC EPOXY COATING

EF EXHAUST FAN

EFTR EXISTING FINISH TO REMAIN

EJT EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

EMERG EMERGENCY

EO ELECTRICAL OUTLET

EPDM ETHYLENE PROPYLENE

DIENE MONOMER

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EXH EXHAUST HOOD

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

EXT-P EXTERIOR PAINT

EXT-ST EXTERIOR STAIN

F

FA FIRE ALARM

FAP FIRE ALARM PANEL

FB FIRE BLANKET

FD FLOOR DRAIN

FDN FOUNDATION

FDV FIRE DEPARTMENT VALVE

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FGS FOAM GASKET SEAL

FH FIRE HOSE

FHV FIRE HOSE VALVE

FIN FINISH

FIXT FIXTURE

FL FLOOR

FL FLOW LINE

FP FIRE PROOFING

H

H HIGH

HB HOSE BIB

HD HAND DRYER

HDCP HANDICAP

HDR HEADER

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HPT HIGH POINT

HR HANDRAIL

HT HEIGHT

HTR HEATER

HVAC HEATING, VENTILATING,

AIR CONDITIONING

HW HOT WATER

HWD HARDWOOD

I

IC INTERCOM

ID INSIDE DIAMETER

IN INCH

INSUL INSULATION

INT INTERIOR

ISO ISOLATION

J

JAN JANITOR

JB JUNCTION BOX

JST JOIST

JT JOINT

K

KO KNOCK OUT

L

L LAVATORY

LB POUND

LCD LINEAR CEILING DIFFUSER

LF LINE FIGURED

LIN LINEAR

LKR LOCKER

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMC LINEAR METAL CEILING

LOC LOCATION OR LOCATE

LPT LOW POINT

LS LAWN SPRINKLING

LT LIGHT

LTG LIGHTING

LVR LOUVER

LWC LINEAR WOOD CEILINGM

MAT MATERIAL

MAX MAXIMUM

MBD MARKER BOARD

MC MEDICINE CABINET

MCU MODULAR COOLING UNIT

MECH MECHANICAL

MEMB MEMBRANE

MET METAL

MRF MANUFACTURER

MH MANHOLE

MIL MILLIMETER

MN MINIMUM

MR MIRROR

MISC MISCELLANEOUS

MO MASONRY OPENING

MONO MONOLITHIC

MPU MULTI- PURPOSE UNIT

MTD MOUNTED

MTL METAL

MTR MOTOR

MULL MULLION

P

PNL PANEL

PR PAIR

PRELIM PRELIMINARY

PRES PLASTIC RESIN

PRESS PRESSURE

PRIM PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PTC PAPER TOWEL CABINET

PTR PRINTER

PVC POLYVINYL CHLORIDE

R

R RADIUS

R RISER

RA RETURN AIR

RB RESILIENT BASE/RUBBER BASE

RD ROOF DRAIN

REC RECESSED

REF REFERENCE

REFR REFRIGERATOR

REG REGISTER

REIN REINFORCE/-ED/-ING

REM REMOVE

REQD REQUIRED

RET RETAINING

REV REVERSE

REV REVISE

RF RESILIENT FLOOR

RFI REQUEST FOR INFORMATION

RH ROOF HATCH

RM ROOM

RO ROUGH OPENING

RS ROUGH SLAB

RSF RESILIENT SHEET FLOOR

RWC RAIN WATER CONDUCTOR

S

S SINK

S STAIN

SCHED SCHEDULE

SD SHOWER DRAIN

SD SMOKE DAMPER

SDISP SOAP DISPENSER

SF STORE FRONT

SF SQUARE FOOT

SH SHOWER

SHT SHEET

SHTG SHEATHING

SIM SIMILAR

SM SURFACE MOUNTED

SNC SANITARY NAPKIN CABINET

SND SANITARY NAPKIN DISPOSER

SP STANDPIPE

SPEC SPECIFICATIONS

SPR SINGLE PLY ROOF

SQ SQUARE

SQ YD SQUARE YARD

SR SERVICE RECEPTOR

SS SERVICE SINK

SST STAINLESS STEEL

ST STREET

ST STONE TILE

STC SOUND TRANSMISSION

STD STANDARD

STL STEEL

STOR STORAGE

STRUC STRUCTURAL

T

T TOP

TAN TANGENT

TCAB TOWEL CABINET

TDR TRENCH DRAIN

TEL TELEPHONE

TEMP TEMPERATURE

TER TERRAZZO

TG TONGUE & GROVE

THRES THRESHOLD

TPH TOILET PAPER HOLDER

TR TREAD

TRANSF TRANSFORMER

TS TUBE SECTION

TV TELEVISION

TYP TYPICAL

U

U URINAL

UC UNDERCUT

UC UNDERCOUNTER

UFD UNDER FLOOR DUCT

UG UNDERGROUND

UH UNIT HEATER

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

US UTILITY SHELF

UTIL UTILITY

V

VC VALVE CABINET

VCT VINYL COMPOSITION TILE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VR VAPOR RETARDER

VTR VENT THROUGH ROOF

W

W WALL COVERING

W WIDTH/WIDE

W WIDE FLANGE

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WDW WINDOW

WG WALL GUARD

WH WALL HYDRANT

WHCH WHEELCHAIR

WHTR WATER HEATER

WP WALL PANEL

WP WATERPROOF

WR WASTE RECEPTACLE

WS WEATHERSTRIP

WSCT WAINSCOT

WSF WELDED SEAM-RESILIENT

SHEET FLOORING

WT WINDOW TREATMENT

WT WEIGHT

WW WOOD WINDOW

N

NA NOT APPLICABLE

NC NURSE CALL

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NT NOTE

NTS NOT TO SCALE

O

OC ON CENTER

OD OUTSIDE DIAMETER

OFF OFFICE

OH OVERHEAD

OP OPERABLE PARTITION

OPER OPERATOR

OPNG OPENING

OPP OPPOSITE

OFD OVERFLOW ROOF DRAIN

P

P PAINT

PART PARTITION

PB PUSH BUTTON

F

FRMG FRAMING

FSTOP FIRE STOPPING

FT FOOT/FEET

FTG FOOTING

FURR FURRING

G

GA GAUGE

GAL GALLONS

GALV GALVANIZED

GB GRAB BAR

GB GRADE BEAM

GC GENERAL CONTRACTOR

GEN GENERAL

GEN GENERATOR

GL GLASS

GR GRADE

GRT GROUT

GWB GYPSUM WALLBOARD

GYP GYPSUM

PC PRECAST CONCRETE

PCD PAPER CUP DISPENSER

PED PEDESTAL

PL PLATE

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLS PLASTER

1. DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. VERIFY

ALL DIMENSIONS PRIOR TO START OF WORK. IN THE EVENT OF

DISCREPANCY, NOTIFY THE ARCHITECT AND OBTAIN RESOLUTION

BEFORE PROCEEDING.

2. ALL SLEEVES, OPENINGS, ETC. FOR CONDUIT, PIPES, DUCTS, ETC.

(OUTSIDE OF RATED CHASES) THROUGH FLOOR SLABS, SMOKE

PARTITIONS AND RATED PARTITIONS ARE TO BE FIRE SEALED IN

ACCORDANCE WITH FIRE RATED ASSEMBLY DESIGNS, APPLICABLE

CODES AND FIRE MARSHALL’S REQUIREMENTS.

3. PROVIDE ALL BLOCKING AND ANCHORAGE AS NECESSARY FOR

PROPER INSTALLATION OF WALL HUNG OR WALL MOUNTED EQUIPMENT

FIXTURES.

4. THE FACE OF EVERY CONTINUOUS PARTITION SHALL BE FLUSH

WITHOUT CHANGES IN PARTITION THICKNESS SHALL OCCUR AT

CORNERS OR OTHER FEATURES WHICH INTERRUPT THE PLANE OF

PARTITION. FACES OF CORRIDOR PARTITIONS SHALL ALIGN ALONG

THEIR ENTIRE LENGTH REGARDLESS OF CHANGES IN PARTITION

THICKNESS. ALL ADJUSTMENTS ARE TO BE MADE TO THE ROOM SIDE OF

THE CORRIDOR PARTITIONS AND AT CORNERS.

5. ADDITIONAL PLAN INFORMATION IS SHOWN ON LARGER SCALE PLANS

WHERE INDICATED BY KEYED REFERENCE. LARGE SCALE DRAWINGS

TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS.

6. THE LIST OF ABBREVIATIONS IS SHOWN AS A GUIDE ONLY AND DOES

NOT NECESSARILY INCLUDE ALL ABBREVIATIONS USED. OTHER

ABBREVIATIONS MAY BE FOUND AMONG THE DRAWINGS.

7. ALL CONSTRUCTION SHALL MEET OR EXCEED LOCAL INDUSTRY

STANDARDS. DETAILS ARE PROVIDED TO INDICATE MINIMUM QUALITY

AND TO GIVE STANDARDS OF CONSTRUCTION. IF A CONDITION IS NOT

SPECIFICALLY DETAILED, SUBMIT A SIMILAR DETAIL FOR GUIDE AND

APPROVAL. UFC 3-600-01, NFPA 101 AND 5000.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08-6231

A

ROCKY MOUNTAIN NETWORK 19

MONTANA VA HEALTH CARE

SYSTEM (436)

3687 VETERANS DRIVE FORT

HARRISON, MT 59636-1500

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project COR

Revisions: Date:

NAME:

Sheet of

FULLY SPRINKLED

TITLE:

PHONE:

EMAIL:

ENDOSCOPY SUITE FINISH

ENHANCEMENT

436-23-132COVER SHEET

G-0.00

DJADJA

FORT HARRISON, MT

12/22/2023

DARIN ARMSTRONG

PROJECT ACTIVATION SPECIALIST

D-1.01 SELECTIVE DEMOLITION PLAN

AutoCAD SHX Text

SYMBOL LEGEND

AutoCAD SHX Text

ACCESSIBILITY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08-6231

A

ROCKY MOUNTAIN NETWORK 19

MONTANA VA HEALTH CARE

SYSTEM (436)

3687 VETERANS DRIVE FORT

HARRISON, MT 59636-1500

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project COR

Revisions: Date:

NAME:

Sheet of

FULLY SPRINKLED

TITLE:

PHONE:

EMAIL:

ENDOSCOPY SUITE FINISH

ENHANCEMENT

436-23-132AREA OF WORK

PROPOSED ICRA PLAN

G-1.00

DJADJA

FORT HARRISON, MT

12/22/2023

DARIN ARMSTRONG

PROJECT ACTIVATION SPECIALIST

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text 1542C

AutoCAD SHX Text

PAT. CORR.

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

PAT. CORR.

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

PROPOSED ICRA PLAN

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

VHAFHMArmstD white

VHAFHMArmstD Text Box

HATCH DENOTES AREA OF WORK

VHAFHMArmstD Polygon

VHAFHMArmstD PolyLine

VHAFHMArmstD

DIMENSION

3'-8"

VHAFHMArmstD PolyLine

VHAFHMArmstD Text Box

PROPOSED HARDWALL ICRA BARRIER

VHAFHMArmstD Callout

MINIMUM OF 44" CLEAR PATHWAY FOR EGRESS TO STAIR

REMOVE DOOR AS NEEDED FOR NEW SCHEDULED FLOOR FINISH.

SEE PLUMBING DEMOLITION PLAN FOR ADDITIONAL INFORMATION REGARDING THIS EXISTING

PLUMBING FIXTURE.

REMOVE AND RETAIN EXISTING CORNER GUARD COVER AND RETAINER AS NEEDED TO INSTALL NEW

SCHEDULED FLOOR FINISH. COORDINATE STORAGE WITH VA COR IF NEEDED.

REMOVE EXISTING 12" HIGH RIGID VINYL RUB RAIL IN ITS ENTIRETY. PATCH AND REPAIR WALL AS

NEEDED FOR NEW SCHEDULED FINISH AND WALL PROTECTION.

GC TO COORDINATE REMOVAL OF GAS CYLINDERS WITH VA COR.

1. INFECTION CONTROL WILL CONSIST OF TEMPORARY “POLY” BARRIERS. REPLACE

TEMPORARY BARRIER IN ITS ENTIRETY AS NEEDED IF BARRIER IS TORN OR DAMAGED

DURING THE WORK.

2. FOR WORK OCCURING AFTER HOURS, CONTRACTOR, EXERCISING CARE, WILL REMOVE

TEMPORARY “POLY” BARRIER MATERIALS TO MINIMIZE SPREADING OF DIRT AND

DEBRIS THIRTY MINUTES PRIOR TO THE COMMENCEMENT OF REGULAR HOSPITAL

HOURS

3. CONTRACTOR TO PROVIDE “WALK OFF” OR “STICKY” MATS AT THE ENTRY AND EXITS TO

THE AREA OF WORK. REPLACE AS NEEDED. CONSTRUCTION PERSONNEL ARE

REQUIRED TO ENSURE SHOES ARE NOT TRACKING WHEN LEAVING THE WORK SITE

4. CONTRACTOR TO PROVIDE HEPA FILTRATION “NEGATIVE AIR” MACHINES AND OTHER

ACTIVE MEANS (TOOL VACUUM SYSTEMS) WHEN DEEMED NECESSARY TO PREVENT

AIR-BONE DUST FROM DISPERSING INTO THE ATMOSPHERE WITHIN THE WORKSITE.

5. CONTRACTOR IS TO ISOLATE ALL AIR VENTS WITHIN THE AREA OF WORK. ISOLATION

OF AIR VENTS AS REQUIRED TO PREVENT AIRBORNE DUST FROM ENTERING THE

VENT/DUCT. CONTRACTOR TO REMOVE VENT/DUCT ISOLATION BARRIERS AT THE END

OF THE WORK PERIOD AND 30 MINUTES BEFORE REGULAR HOSPITAL HOURS ARE TO

COMMENCE.

6. TEMPORARY BARRIERS WILL BE ERECTED SO AS TO NOT IMPEDE ACCESS TO

REMAINING AREAS OF THE FACILITY FOR PATIENTS, VISITORS AND HOSPITAL STAFF.

7. ALL DEBRIS MUST BE REMOVED BY CART/CONTAINER WITH A TIGHTLY COVERED LID,

NO EXCEPTIONS WILL BE ALLOWED.

8. CONTRACTOR TO MAINTAIN A CLEAN AND ORDERLY, DUST, DEBRIS, TRIP HAZARD FREE

WORK AREA ON A DAILY BASIS DURING REGULAR HOSPITAL HOURS. CONTRACTOR TO

WIPE WORK SURFACES WITH DISINFECTANT, WET MOP AND/OR VACUUM WITH HEPA

FILTERED VACUUM BEFORE LEAVING THE WORK AREA AT THE END OF EACH WORK DAY

OR THIRTY MINUTES BEFORE REGULAR HOSPITAL HOURS ARE TO COMMENCE.

9. IN THE EVENT THAT AN EXISTING FIRE EXTINGUISHER IS NOT READILY ACCESSIBLE DUE

TO THE ERECTION OF TEMPORARY BARRIERS, THE CONTRACTOR WILL PROVIDE A FIRE

EXTINGUISHER OUTSIDE OF THE AREA OF WORK.

10. CONTRACTOR TO FIELD VERIFY ALL SITE CONDITIONS PRIOR TO COMMENCING WITH

THE WORK. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S

REPRESENTATIVE (COR) OF ANY DISCREPANCIES NOT SHOWN ON THE PLAN(S) PRIOR

TO COMMENCING WITH THE WORK.

11. SEE INFECTION CONTROL PLAN (IC SERIES) AND PHASING PLAN (PH SERIES) FOR

ADDITIONAL INFORMATION FOR PROPOSED INFECTION CONTROL BARRIERS AND

PHASING FOR EACH AREA OF WORK REQUIRED. CONTRACTOR WILL BE RESPONSIBLE

FOR COORDINATING THE WORK AND THE APPROPRIATE INFECTION CONTROL BARRIER

AS NEEDED TO ACCOMPLISH THE WORK. COORDINATE ALL PROPOSED BARRIERS WITH

THE COR THAT MAY NEED TO BE CREATED TO ACCOMODATE VARIOUS TRADES AS

NEEDED.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08-6231

A

ROCKY MOUNTAIN NETWORK 19

MONTANA VA HEALTH CARE

SYSTEM (436)

3687 VETERANS DRIVE FORT

HARRISON, MT 59636-1500

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project COR

Revisions: Date:

NAME:

Sheet of

FULLY SPRINKLED

TITLE:

PHONE:

EMAIL:

ENDOSCOPY SUITE FINISH

ENHANCEMENT

436-23-132SELECTIVE DEMOLITION PLAN

D-1.01

DJADJA

FORT HARRISON, MT

12/22/2023

DARIN ARMSTRONG

PROJECT ACTIVATION SPECIALIST

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

ENDO.

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text

ENDO.

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text

END0.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text

ENDO.

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text

ENDOSCOPY

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text

COMMON

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

COMMON

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text

EMS

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

COMMON

AutoCAD SHX Text

COMMON

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

SELECTIVE DEMOLITION PLAN

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

SELECTIVE DEMOLITION PLAN SHEET NOTES:

DEMOLITION PLAN GENERAL NOTES:

FULL HEIGHT VINYL

CORNER GUARD

FASTENED TO WALL

SURFACE

CONTINUOUS ALUMINUM

RETAINER

SELF TAPPING SCREWS

VA

R.

SCHEDULED BASE

CRASH RAIL, BR -1

TOGGLE BOLT

ALUMINUM ANCHOR BRACKETS OR

CONTINUOUS RETAINER

NEOPRENE CUSHION AT EACH FASTENING

VAR.

4"

4'- 0"

VA

R.SCHEDULED BASE

WALL GUARD WG-1

3'- 0"

VA

R.SCHEDULED BASE

RUB RAIL, RB-1 8"

EDGE TRIM AND

SEALANT

WP-1 WP-2 WP-8

CG-2

CG-2

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

W P-

W P-

W P-

WP-2

WP-2

WP-2

WP-2

W P-2

W P-

WP-1

FULL HEIGHT VINYL

CORNER GUARD

FASTENED TO PARTITION

CONTINUOUS ALUMINUM

RETAINER

SELF TAPPING SCREWS

SCHEDULED PARTITION

ROOM FINISH SCHEDULE

ROOM NUMBER ROOOM NAME FLOOR BASE WALLS CELING FINISH SIGN TYPE REMARKS

RES-1 RES-1 SC-1, WG-1 EXISTING N.I.C.362D CLEAN UTILITY

GAS CYLINDER STOR.

WORKSTATION

363A 363B

363E PROCEDURE 1

PROCEDURE 2

VESTIBULE

363 WORK AREA

-363C PATIENT RR EXISTING

P- 1 P- 1,P-3 P- 1, P-3

SC- 1

CT (EXISTING), SC-1

SC-1

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

FINISH SCHEDULE

FINISH MARK FINISH MANUFACTURER PATTERN/STYLE COLOR SIZES COMMENTS

FLOOR

RES-1 RESINOUS FLOORING STONHARD STONTEC TRF TO BE SELECTED

TS-1 TRANSITION STRIP SCHLUTER SCHLUTER RENO-T STAINLESS STEEL RESILIENT FLOOR TO RESILENT FLOOR

WALLS

P-1 PAINT SHERWIN WILLIAMS SW7638 JOGGING PATH

P-2 PAINT SHERWIN WILLIAMS SW6107 NOMADIC DESERT

SC-1 HIGH BUILD GLAZED COATING SHERWIN WILLIAMS SW6133

FIELD WALL PAINT, ACRYLIC LATEX, SEMI-GLOSS

HM DOOR TRIM PAINT, ACRYLIC LATEX, SEMI-GLOSS

HIGH BUILD, EPOXY PAINT FINISH, SEMI-GLOSSMUSLIN

WALL PROTECTION

RR-1 RIGID VINYL C/S GROUP 8" RUB RAIL 479 CAPPUCCINO

WG-1 RIGID VINYL 48" H WITH MATCHING EDGE TRIM

BR-1 CRASH RAIL

-8" HIGH

SCR-40

4" HIGH

SURFACE MOUNTED, CONT. ALUM. RETAINER

C/S GROUP

ACCENT WALL, PAINT P-3.

PAINT ABOVE EXISTING CERAMIC TILE WAINSCOT, SC-1

FLOOR TRANSITION FROM EPOXY FLOORING TO EXISTING LVT

FLOOR TRANSITION FROM EPOXY FLOORING TO EXISTING CERAMIC TILE

LINE OF EXISTING COUNTER TOP TO REMAIN.

EXISTING SURFACE MOUNTED DOOR AUTOMATIC DOOR BOTTOMS MAY

REQUIRE ADJUSTMENT TO CONFORM TO NEW SCHEDULED FLOOR FINISH.

CONTRACTOR TO CONFIRM AND ADJUST AS REQUIRED TO MAINTAIN SEAL.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08-6231

A

ROCKY MOUNTAIN NETWORK 19

MONTANA VA HEALTH CARE

SYSTEM (436)

3687 VETERANS DRIVE FORT

HARRISON, MT 59636-1500

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project COR

Revisions: Date:

NAME:

Sheet of

FULLY SPRINKLED

TITLE:

PHONE:

EMAIL:

ENDOSCOPY SUITE FINISH

ENHANCEMENT

436-23-132FINISH PLAN

WALL PROTECTION PLAN

A-1.03

DJADJA

FORT HARRISON, MT

12/22/2023

DARIN ARMSTRONG

PROJECT ACTIVATION SPECIALIST

6" HIGH, INTEGRATED BASE W/ TOP CAP

362J 362K

RES-1 RES-1

RES-1 RES-1

RES-1 RES-1 SC-1, WG-1 EXISTING N.I.C.362F SOILED UTILITY

RES-1 RES-1

B

REMARKS:

A. PAINT SC-1 ABOVE NEW WALL PROTECTION, WG-1

B. PAINT SC-1 ABOVE EXISTING CERAMIC TILE WAINSCOT

RES-1 RES-1

RES-1 RES-1

SC-1RES-1 RES-1

A A

253 PARCHMENT

479 CAPPUCCINOC/S GROUP

P-3 PAINT SHERWIN WILLIAMS SW7601 DOCKSIDE BLUE ACCENT WALL PAINT, ACRYLIC LATEX, SEMI-GLOSS

RE-USE EXISTING CORNER GUARDS

16" SMALL FLAKE

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

PAT. CORR.

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 361C

AutoCAD SHX Text 362K

AutoCAD SHX Text 363A

AutoCAD SHX Text

AutoCAD SHX Text 362J

AutoCAD SHX Text 363C

AutoCAD SHX Text 362D

AutoCAD SHX Text 363B

AutoCAD SHX Text 363E

AutoCAD SHX Text 362F

AutoCAD SHX Text 361B

AutoCAD SHX Text 361A

AutoCAD SHX Text

AutoCAD SHX Text 154B

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

FINISH PLAN

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text 1 1/2" = 1'-0"

AutoCAD SHX Text

WALL PROTECTION TYPES

AutoCAD SHX Text

AutoCAD SHX Text 6" = 1'-0"

AutoCAD SHX Text

CORNER GUARD CG-1

AutoCAD SHX Text

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

WALL PROTECTION PLAN

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text 6" = 1'-0"

AutoCAD SHX Text

CORNER GUARD CG-2

AutoCAD SHX Text

AutoCAD SHX Text

FINISH PLAN SHEET NOTES:

WALL PROTECTION PLAN SHEET NOTES:

SWITCH, SINGLE POLE

SYMBOL

ELECTRICAL SYMBOL LEGEND

DESCRIPTION

SWITCH, 3-WAY

SWITCH, MOTOR CONTROL

J

QUADRAPLEX OUTLET

DUPLEX OUTLET

JUNCTION BOX, WALL

DISCONNECT SWITCH

OC OCCUPANCY SENSOR SWITCH, CEILING MOUNTED

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN ACCORDANCE

WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED PROCEDURES, ALL

APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST EDITION

OF THE NATIONAL ELECTRICAL CODE.

PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE BUILDING

CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES.

VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED MOUNTING

HARDWARE TO SUIT THE PARTICULAR INSTALLATION.

PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.

BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.

COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO AVOID

CONFLICT DURING CONSTRUCTION.

ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR

SPACE.

MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER.

PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE ACCEPTED. ALL PRODUCTS MUST

COMPLY WITH "BUY AMERICAN ACT".

ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR

EQUIPMENT MANUFACTURER'S SPECIFICATIONS.

CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE

DEVICE'S SCREW TERMINALS.

MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT UNLESS

NOTED OTHERWISE.

ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.

ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.

ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. LFMC CONDUIT SHALL BE USED ON VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND CONDUIT OR WHERE CONCRETE-ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE, LFMC CONDUIT

SHALL BE USED (MAXIMUM SIX FEET) FOR FINAL CONNECTIONS.

ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN

APPROVED THIRD PARTY TESTING AGENCY (NRTL).

FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE

SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC

PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE

MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT

BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.

PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS DETERMINED BY THE

GOVERNMENT, SHALL BE PROVIDED.

COMPRESSION COUPLINGS SHALL BE USED FOR EMT SIZED 3/4" TO 2".

ELECTRICAL CONTRACTOR SHALL FOLLOW SITE LOCK-OUT/TAG-OUT GUIDELINES TO DEENERGIZE

EQUIPMENT.

ELECTRICAL CONTRACTOR TO CONTACT COR FOR DISPOSAL OF REMOVED ELECTRICAL EQUIPMENT.

ALL NEWLY INSTALLED PANELS SHALL BE LABLED ACCORDING TO NEC ARTICLE 110.

NEW 110V/15A OUTLET FOR NEW AUTO FLUSH FAUCET SET, SEE PLUMBING

PLAN FOR ADDITIONAL INFORMATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08-6231

A

ROCKY MOUNTAIN NETWORK 19

MONTANA VA HEALTH CARE

SYSTEM (436)

3687 VETERANS DRIVE FORT

HARRISON, MT 59636-1500

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project COR

Revisions: Date:

NAME:

Sheet of

FULLY SPRINKLED

TITLE:

PHONE:

EMAIL:

ENDOSCOPY SUITE FINISH

ENHANCEMENT

436-23-132ELECTRICAL POWER PLAN

E-1.01

DJADJA

FORT HARRISON, MT

12/22/2023

DARIN ARMSTRONG

PROJECT ACTIVATION SPECIALIST

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

PAT. CORR.

AutoCAD SHX Text

AutoCAD SHX Text

MC

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

POWER PLAN

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

ELECTRICAL PLAN SHEET NOTES:

ELECTRICAL GENERAL NOTES:

7.68" (195 mm) 2.48" (63 mm)

8.70” (221 mm)

30° 5.90” (150 mm)

140 mm (5.51”)

1.14" (29 mm)

14.29” (363 mm)

3.07" (78 mm)

Connection to Power Supply Unit

PSU Mains Cable 6'6" (2 m)

PSU

Total Cable Run: 3'6" (1.09 m) Total Cable Run with Extension Cable: 11'9" (3.59 m)

PSU 12V Cable

3'3" (1.0 m)

Extension Cable

8'2" (2.5 m)

Product Tail

3.5" (0.09 m) TAP

REMOVE EXISTING SCULLERY SINK, EYE WASH AND PRE-RINSE FAUCET

SET. RETAIN FOR RE-USE ONCE SCHEDULED FLOORING AND WALL

PROTECTION IS INSTALLED. COORDINATE STORAGE WITH VA COR.

DISENGAGE NEPTUNE SUCTION DEVICE DOCKING STATION AS REQUIRED

REINSTALL ONCE NEW SCHEDULED FLOORING AND WALL PROTECTION IS

INSTALLED. COORDINATE STORAGE WITH COR AND VA BIO-MED STAFF.

REMOVE EXISTING FAUCET SET AND FOOT PEDAL CONTROL VALVE

ASSEMBLY IN ITS ENTIRETY. PREP LAVATORY SINK AS REQUIRED FOR NEW

AUTO FLUSH FAUCET SET AND RELATED CONTROL APPARATUS.

1 WORK SHALL CONFORM TO APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND APPLICABLE VA STANDARDS.

2 INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS.

3 OBTAIN AND PAY FOR PERMITS, FEES, AND INSPECTIONS REQUIRED FOR THIS WORK.

4 PROVIDE NEW MATERIALS, EQUIPMENT AND PRODUCTS INCORPORATED IN THE WORK, OF A SUITABLE GRADE FOR THE PURPOSES INTENDED.

5 EQUIPMENT OR MATERIAL DEVIATIONS FROM INDICATED CONTRACT REQUIREMENTS SHALL BE SUBJECT TO THE APPROVAL OF THE COR. SUBMIT PROPOSED EQUIPMENT DEVIATIONS THAT ARE SIMILAR BOTH IN QUALITY AND CAPACITY TO THAT EQUIPMENT SPECIFIED, AS SOLELY DETERMINED BY THE COR.

6 INSTALL EQUIPMENT AS INDICATED, ALLOWING FOR SUFFICIENT ACCESS AND CLEARANCE SPACE FOR EQUIPMENT MAINTENANCE, REPAIRS, AND REPLACEMENT.

7 PLUMBING FIXTURES SHALL HAVE A PISTON TYPE WATER HAMMER ARRESTOR SIZED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.

8 SANITARY SEWER PIPING IS LOCATED BELOW FLOOR SLAB OR WITHIN WALLS UNLESS NOTED OTHERWISE. SANITARY VENT PIPING SHOWN IS ABOVE THE CEILING OR

WITHIN WALLS UNLESS NOTED OTHERWISE.

9 SUPPORT PIPING SYSTEM AS REQUIRED BY LOCAL, STATE, AND NATIONAL CODES ALONG WITH SPECIFICATIONS, VA STANDARDS AND MANUFACTURER'S RECOMMENDATIONS.

10 PIPING PENETRATIONS THROUGH NEW OR EXISTING WALLS OR FLOORS SHALL BE SEALED TO EQUAL THE FIRE RATING OF THE NEW OR EXISTING WALL OR FLOOR.

11 PLUMBING SYSTEM SHALL BE TESTED AS REQUIRED PER ALL LOCAL, STATE, AND NATIONAL CODES ALONG WITH ALL VA STANDARDS.

12 COORDINATE ALL PLUMBING PIPING WITH ALL STRUCTURAL COMPONENTS.

13 DISINFECT THE DOMESTIC WATER SYSTEM IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL CODES ALONG WITH ALL VA STANDARDS.

14 PROVIDE SHUT OFF VALVES AT BRANCH PIPING TO FIXTURES.

15 COORDINATE PLUMBING WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION. CONTRACTOR SHALL COORDINATE ROUTING OF ALL PIPING WITH EXISTING CONDITIONS AND SHALL PROVIDE ANY NECESSARY OFFSETS, REROUTING, ETC. REQUIRED FOR A COMPLETE AND COORDINATED INSTALLATION.

16 PROVIDE ALL NECESSARY OFFSETS, TEES, ELBOWS, ETC. FOR A COMPLETE WORKING PLUMBING SYSTEM. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL

LOCATION AND ARRANGEMENT OF PIPING SYSTEMS.

17 CONTRACTOR SHALL COORDINATE ANY PLUMBING SYSTEM REQUIRED SHUTDOWN WITH THE OWNER 2 WEEKS IN ADVANCE.

18 PATCH, PAINT AND CLEAN SURFACES SUSTAINING DAMAGE ASSOCIATED WITH PLUMBING WORK OF THIS CONTRACT, UNLESS NOTED OTHERWISE.

19 SUBMIT BOUND SET OF OPERATING AND MAINTENANCE INSTRUCTIONS FOR EQUIPMENT AT COMPLETION OF PROJECT.

20 INSTALL ESCUTCHEONS IN ALL PLACES WHERE PIPING PENETRATES A WALL.

21 TWO ELECTRONIC COPIES OF OPERATION AND MAINTENCE MANUALS IS REQUIRED.

22 INSULATE WATER PIPES ALL THE WAY TO THE FAUCET.

23 PROVIDE REMOVABLE PAD INSULATION FOR ALL PLUMBING FEATURES AND DETAILS. REFRENCE SPEC. SECTION 22 07 11, PLUMBING INSULATION FOR MORE INFORMATION AND

INSULATION SCHEDULE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08-6231

A

ROCKY MOUNTAIN NETWORK 19

MONTANA VA HEALTH CARE

SYSTEM (436)

3687 VETERANS DRIVE FORT

HARRISON, MT 59636-1500

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project COR

Revisions: Date:

NAME:

Sheet of

FULLY SPRINKLED

TITLE:

PHONE:

EMAIL:

ENDOSCOPY SUITE FINISH

ENHANCEMENT

436-23-132PLUMBING DEMOLITION PLAN

PLUMBING PLAN

P-1.01

DJADJA

FORT HARRISON, MT

12/22/2023

DARIN ARMSTRONG

PROJECT ACTIVATION SPECIALIST

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE MANUFACTURER MODEL COMMENTS

FS-1 LAVATORY FAUCET SET ARMSTRONG RADA MX1-20

QTY

1 SEE DETAIL, THIS SHEET

POWER DATA

YES YES

INSTALL NEW FAUCET SET, FS-1. COORDINATE POWER OUTLET AND DATA

CONNECTION AS REQUIRED FOR A COMPLETE SYSTEM.

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

PAT. CORR.

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

PAT. CORR.

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

PLUMBING DEMOLITION PLAN

AutoCAD SHX Text

AutoCAD SHX Text

PLUMBING DEMOLITION PLAN SHEET NOTES:

AutoCAD SHX Text

PLUMBING GENERAL NOTES:

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

PLUMBING PLAN

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

DETAIL - FS-1

AutoCAD SHX Text

PLUMBING PLAN SHEET NOTES:

J

E NURSE CALL, EMERGENCY PULL CORD

SYMBOL

TELECOM/SECURITY SYMBOL LEGEND

DESCRIPTION

TV

DATA PORT OUTLET

TV OUTLET, CABLE

S DA DURESS ALARM

WAP, WIRELESS ACCESS POINT

RTLS, STAR DEVICE, POE

RTLS, MONITOR DEVICE, BATTERY POWER

RTLS, VIRTUAL WALL DEVICE, BATTERY POWER

CARD ACCESS, PROXIMITY CARD READERS

CR

S DPS

S ES

S

KP CARD ACCESS, KEY PAD

DOOR POSITION SWITCH

ELECTRIC STRIKE

CAMERA, SECURITY

J DATA, SINGLE GANG UTILITY BOX

FINISHED FLOOR

MOUNTING HEIGHT AS

SHOWN IN DRAWINGS

4-11/16" SQ. BY 2-1/2"

DEEP BOX WITH SINGLE

GANG 5/8" TILE RING.

1-1/4" CONDUIT WITH

COMMUNICATIONS WIRING

WALL

CORRIDORROOM

6" NYLON BUSHING

COORDINATE WITH DUCTWORK

EXTEND CONDUIT TO ABOVE

FINISHED ACCESSABLE

CEILING IN CORRIDOR TO

CABLE TRAY UNLESS NOTED

OTHERWISE.

SUSPENDED LAY-IN

CEILING

CABLE TRAY

NEW DATA LINE CONNECTION WITH SINGLE GANG UTILITY BOX , COORDINATE CABLING

AND TERMINATION END AS REQUIRED FOR NEW AUTO FLUSHING FAUCET SET DEVICE.

CABLE TO BE RUN TO OIT ROOM, #368 TO EXISTING FRONT END CONTROL DEVICE.

1. ALL COMMUNICATIONS DEVICES AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL

CODE, BICSI STANDARDS AND VA STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, AND EQUIPMENT WHERE THE BUILDING CONSTRUCTION IS

NOT SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILINGS, AND ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES.

4. ALL CABLING SHALL COMPLY WITH THE LATEST EDITION OF TELECOMMUNICATIONS DISTRIBUTION METHOD

MANUAL AND ANSI/TIA/EIA PUBLICATIONS.

5. COMPLY WITH ANSI/TIA/EIA 758 AND 607B OR 607A - GROUNDING AND BONDING REQUIREMENTS FOR

TELECOMMUNICATIONS IN COMMERCIAL BUILDING.

6. COMPLY WITH ANSI/TIA/EIA 568B - COMMERCIAL BUILDING TELECOMMUNICATIONS WIRING STANDARD.

COMPLY WITH ANSI/TIA/EIA 569B - COMMERCIAL BUILDING STANDARD FOR TELECOMMUNICATIONS PATHWAYS

AND SPACES.

8. COMPLY WITH NFPA 70 NATIONAL ELECTRIC CODE.

9. COMPLY WITH NFPA 99 HEALTHCARE FACILITIES CODE.

10. COMPLY WITH NFPA 101 LIFE SAFETY CODE.

11. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO AVOID

CONFLICT DURING CONSTRUCTION.

12. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER.

PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE ACCEPTED. ALL PRODUCTS MUST

COMPLY WITH "BUY AMERICAN ACT".

13. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, BOXES, OUTLET, OR EQUIPMENT UNLESS NOTED

OTHERWISE.

14. ALL CONDUITS SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED.

15. ALL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED THIRD

PARTY TESTING AGENCY.

16. ANY DISCREPANCY BETWEEN PLANS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE VA COR, ARCHITECT, AND ENGINEER OF RECORD FOR CLARIFICATION. THE MORE STRINGENT OF THE THEM

SHALL TAKE PRECEDENCE.

17. ANY LOCATION (CORRIDOR, ROOM OR ADJACENT SPACE) WITH TWO OR MORE VISIBLE FIRE ALARM NOTIFICATION APPLIANCES WITHIN THE FIELD OF VIEW SHALL HAVE VISIBLE APPLIANCES PROGRAMMED TO

FLASH IN SYNCHRONIZATION.

18. ALL COPPER OUTLETS/CONNECTORS SHALL BE TIA/EIA CAT 6A.

19. ALL WORK AREA OUTLETS SHALL BE 8 PIN, CAT 6A KEYSTONE JACK WIRED PER T568A OR T568B AS DIRECTED

BY THE VA COR.

20. LABELING SHALL BE ACCORDING TO LATEST ANSI/TIA 606A OR 606B EDITION AS WELL AS THE STANDARDS

SET FORTH BY THE VA HOSPITAL OIT.

21. PROVIDE A MINIMUM OF 12" CLEARANCE ABOVE THE CABLE TRAY PER TIA/EIA 569.B PARAGRAPH 4.5.6.2.

22. THE VA SHALL CONDUCT A WAP SURVEY AND PROVIDE THE SURVEY TO THE CONTRACTOR. CONTRACTOR

SHALL INSTALL CABLING AND EQUIPMENT PER THE SURVEY. COORDINATE WITH COR/IT.

23. ALL FLOOR PENETRATIONS SHALL BE FIRESTOPPED.

24. CONTRACTOR TO COORDINATE WITH VA SECURITY, COR TO ENSURE COMPATIBILITY OF NEW SYSTEM

WITH EXISTING SECURITY SYSTEM.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08-6231

A

ROCKY MOUNTAIN NETWORK 19

MONTANA VA HEALTH CARE

SYSTEM (436)

3687 VETERANS DRIVE FORT

HARRISON, MT 59636-1500

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project COR

Revisions: Date:

NAME:

Sheet of

FULLY SPRINKLED

TITLE:

PHONE:

EMAIL:

ENDOSCOPY SUITE FINISH

ENHANCEMENT

436-23-132TELECOMMUNICATION PLAN

T-1.00

DJADJA

FORT HARRISON, MT

12/22/2023

DARIN ARMSTRONG

PROJECT ACTIVATION SPECIALIST

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UNIT HEATER

AutoCAD SHX Text

AutoCAD SHX Text

EXAM/CONSULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 361C

AutoCAD SHX Text

VITALS

AutoCAD SHX Text 362K

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text 363A

AutoCAD SHX Text

PROCEDURE #2

AutoCAD SHX Text

AutoCAD SHX Text

WORK AREA

AutoCAD SHX Text 362J

AutoCAD SHX Text

GAS CYL. STOR.

AutoCAD SHX Text 363C

AutoCAD SHX Text

PAT. RR.

AutoCAD SHX Text 362D

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text 363B

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 363E

AutoCAD SHX Text

PROCEDURE #1

AutoCAD SHX Text 362F

AutoCAD SHX Text

SOILED UTIL

AutoCAD SHX Text 361B

AutoCAD SHX Text

FIRE CLST

AutoCAD SHX Text 361A

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

AutoCAD SHX Text

HSKP

AutoCAD SHX Text 154B

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

PAT. CORR.

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

TELECOMMUNICATIONS PLAN

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

TELECOMMUNICATION PLAN SHEET NOTES:

AutoCAD SHX Text

TELECOMMUNICATION/SECURITY GENERAL NOTES:

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

TELEDATA OUTLET INSTALLATION