As builts for Colorado Corridor.pdf
PDF 8 MB Posted
- Solicitation number
- 36C25922R0023
About this file
This document package includes record drawings and plans for plumbing renovations at a Veterans Affairs Medical Center, along with a related federal contract opportunity notice. The plans depict as-built plumbing systems in the basement and first floor of an existing VA facility, and specify demolition and new construction work. Renovations include replacing sections of domestic water piping with new copper lines, installing new circulating pumps, valves and fixtures. The related solicitation seeks proposals to renovate space to support a Substance Abuse Residential Rehabilitation Treatment Program at the VA Medical Center in Grand Junction, Colorado. Offerors are invited to submit bids for construction services that will modify existing areas for the new SARRTP program. The work encompasses plumbing, electrical and other construction disciplines, and will modify areas within the medical center to meet the needs of the substance abuse treatment program.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SARRTP Questions Answers 3.docx | DOCX document | |
| 36C25922R0023 0004.docx | DOCX document | |
| Amendment 3 36C25922R0023 0003.docx | DOCX document | |
| 3 Specifications addendum 1.pdf | ||
| 01 SOW Impact for SARTP By work item addendum 1.docx | DOCX document | |
| B1-1st-HOT-Bldg.-1-1st-Floor--HOT-Samples-Rev.0.pdf | ||
| Fourth Floor Arch.pdf | ||
| B1--4th--HOT-Bldg.-1--4th-Floor--HOT-Samples-Rev.0.pdf | ||
| Asbestos Report SARRTP Impact work areas.xlsx | XLSX spreadsheet | |
| Amendment 2 36C25922R0023 0002.docx | DOCX document | |
| SARRTP Questions Answers.pdf | ||
| S04 -Site Visit Meeting Doc 2.22.docx | DOCX document | |
| Pre Construction Site Visit Attendance.pdf | ||
| Amendment 1 36C25922R0023 0001.docx | DOCX document | |
| 36C25922R0023_1.docx | DOCX document | |
| 3 Plans.pdf | ||
| 3 Specifications.pdf | ||
| Past Performance Questionnaire.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X X X X X X
X X X X X X
X X X X
X X X
X X X X X X
X X X X
X X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXX
X
X
X
X
" C.W.
" H.W.
" H.W.C.
" C.W.
1" H.W.
" H.W.C.
" H.W.R.C.
1"
1"
1"
2"
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
4"
3"
2"
EAST WALL (SOUTH WING) RISER
" C.W.
" H.W.
" H.W.C.
1"
4"
3"
2"
1" W.H.
1"
" C.W.
" H.W.
" H.W.C.
4"
3"
2"
2" C.W.
1" H.W.
" H.W.C.
SOUTH WALL (EAST WING) RISER
" C.W. GALVANIZED UP
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" W.H.
" C.W.
" H.W.
" H.W.C.
2" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
2"
3"
2"
3"
2"
3"
1"
" W.H.
X X
X X
X X
X
X
X X
X X
X X
1" H.W.
" H.W.C.
" H.W.
" H.W.C.
2" C.W.
" H.W.
" H.W.C.
" C.W.
1" H.W.
" H.W.C.
1"
2" C.W.
CAPPED 1" H.W. (VALVE CLOSED)
CAPPED
" H.W.C. (VALVE CLOSED)
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
3"
3" 2"
" C.W.
" H.W.
" H.W.C.
1"
" W.H.
" C.W.
" H.W.
1" H.W.C.
1" C.W.
1" H.W.
" H.W.C.
1"
3"
" C.W.
1" H.W. (CAPPED)
" H.W.C. (CAPPED)
X
1" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
2" C.W.
" H.W.
" H.W.C.
3"
2"
" C.W.
" H.W.
" H.W.R.C.
1"
1"
1"
2"
" C.W.
" H.W.
" C.W.
" H.W.
1"
C.W. & H.W.
TO FIXTURES ABOVE
C.W.
TO FIXTURES ABOVE
" C.W.
" H.W.
C.W. & H.W.
TO FIXTURES ABOVE
MIXING
VALVE
" MIXED
" C.W.
COPPER
T O
C
L C
1"
" C.W.
" H.W.
3" C.W.
H.W. VALVE
12C3R
" C.W.
" H.W.
" H.W.C.
C.W. VALVE # CW11
H.W. VALVE # HW11
H.W.C. VALVE # 5W3R
C.W. VALVE # 8W1C
H.W. VALVE # 1W2H
1"
HW & HWC
CONNECT
H.W. VALVE # 12C2H
2" C.W.
2" H.W.
" H.W.C.
CRAWL SPACE ACCESS
WATER HEATER
X
X
X
SILVER
IONIZATION
EQUIP
H.W. & H.W.C. CONNECT
INCOMING DOMESTIC
WATER SERVICE
X
X
X
X
X
HWCP-1
HWCP-2
PANEL-1EQ0B
J-BOX (E)
W
S
E
N
THESE RECORD DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY
OTHERS. THE DESIGN PROFESSIONAL HAS NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS
OR OMISSIONS WHICH MAY BE INCORPORATED HEREIN AS A RESULT.
RECORD DRAWINGS
NOVEMBER 4, 2016
AutoCAD SHX Text
DN
AutoCAD SHX Text
CRAWL SPACE ACCESS
AutoCAD SHX Text
UP
AutoCAD SHX Text
STEAM TUNNEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A. REMOVE EXISTING PIPING BACK TO ISOLATION VALVE AS REMOVE EXISTING PIPING BACK TO ISOLATION VALVE AS SHOWN AND CAP. B. REMOVE CAPPED PIPING BACK TO POINT SHOWN TO WITHIN REMOVE CAPPED PIPING BACK TO POINT SHOWN TO WITHIN 1'-0" OF EXISTING MAIN. PROVIDE NEW ISOLATION BALL VALVE AND CAP. C. REMOVE EXISTING 1-1/2" GALVANIZED CW RISER IN ITS REMOVE EXISTING 1-1/2" GALVANIZED CW RISER IN ITS ENTIRETY FROM THE END POINT OF THE GALVANIZED RISER IN THE CRAWLSPACE AND UP THROUGH THE FIRST FLOOR AND REPLACE WITH NEW 1-1/2" COPPER PIPE.
AutoCAD SHX Text
DEMOLITION NOTES:
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
NEW WORK NOTES:
AutoCAD SHX Text
1. FOR ENLARGED SCALE PLAN OF NEW CIRCULATING PUMP FOR ENLARGED SCALE PLAN OF NEW CIRCULATING PUMP INSTALLATION SEE SHEET P2.0. 2. PROVIDE NEW BALANCING VALVE IN EXISTING HOT WATER PROVIDE NEW BALANCING VALVE IN EXISTING HOT WATER CIRCULATING PIPING. BALANCE TO GPM AS NOTED. 3. PROVIDE NEW ISOLATION VALVE IN EXISTING PIPING AS PROVIDE NEW ISOLATION VALVE IN EXISTING PIPING AS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. FOLLOWING THE REMOVAL OF DESIGNATED ITEMS OR FOLLOWING THE REMOVAL OF DESIGNATED ITEMS OR INSTALLATION OF NEW ITEMS, THE CONTRACTOR SHALL MAKE ANY NECESSARY REPAIRS TO RESTORE AFFECTED AREAS TO MATCH ADJACENT SURFACES TO THE MAXIMUM EXTENT POSSIBLE. THIS INCLUDES, BUT IS NOT LIMITED TO, REPLACING DAMAGED OR MISSING PIPE INSULATION, PATCHING AND PAINTING DAMAGED WALLS, AND ANY OTHER INCIDENTAL WORK REQUIRED TO RESTORE AREAS TO MATCH ADJACENT SURFACES. THIS WORK INCLUDES REPAIRING PENETRATIONS THROUGH SMOKE AND FIRE BARRIERS LEFT OPEN BY REMOVED ITEMS. THESE AREAS SHALL BE REPAIRED TO MEET THE APPLICABLE VA STANDARDS.
AutoCAD SHX Text
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
1.0 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
1.2 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
1.0 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.6 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
0.7 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
0.5 GPM
AutoCAD SHX Text
1.4 GPM
AutoCAD SHX Text
1.5 GPM
AutoCAD SHX Text J
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text 575-14-828
AutoCAD SHX Text
AutoCAD SHX Text
VAMC
AutoCAD SHX Text Grand Junction
AutoCAD SHX Text
CO
AutoCAD SHX Text Eliminate Domestic Dead
AutoCAD SHX Text End Water Lines
AutoCAD SHX Text
BASEMENT PLUMBING PLAN
AutoCAD SHX Text P1.0
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SMN
AutoCAD SHX Text
JLE
AutoCAD SHX Text Jan, 2015
AutoCAD SHX Text
JOHN BARTMAN
AutoCAD SHX Text
PHONE: 970-242-0731
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BASEMENT PLUMBING PLAN
AutoCAD SHX Text 3/32" = 1' 0"
AutoCAD SHX Text
RECORD DRAWINGS
STORAGE
OFFICE
MECHANICAL
CANTEEN
STORAGE
FREEZER
EMS
1237 ELEVATOR
STAIRWELL
EMS STORAGE
DOCK
CORRIDOR
MECHANICAL
STORAGE
DISHWASHING ROOM
CAFETERIA
RETAIL STORE
OFFICE
CORRIDOR
EXHAUST
ROOM
MAILROOM
1218ELECTRICAL
MECHANICAL
CORRIDOR
CORRIDOR
RESTROOM
HSKPG
MENS
LOCKER
ROOM
WOMEN
TOILET
RESTROOM
EMS STORAGE
AUTO VALET
CORRIDOR
CORRIDOR
MORGUE
MORGUE DOCK
1249LOCKER
RM
HSKPG
ELECTRICAL
EMS
STORAGE
STAIRWELL
MORGUE
ENTRY
ELEVATOR
ELEVATOR
IT
CONSULTATION
CORRIDOR
WAITING ROOM
PATIENT
ALIGNED
CARE
TEAM
PATIENT
ALIGNED
CARE
TEAM
DISABLED
AMERICAN
VETERANS
PATIENT
ADVOCATE
DATA CLOSET
STAIRWELL
VOLUNTARY
SERVICES
VOLUNTEER
SERVICES
SPECIALIST
OFFICE
OFFICE
1409DISABLED
AMERICAN
VETERANS
1411a
POLICE
CHIEF
OFFICE
1411b
PHARMACY
OFFICE
OFFICE
CONSULTATION
PHARMACY
CLINIC
OEF/OIF/OND
OFFICE
STAIRWELL
RESTROOM
1426A
OIT
PHARMACY
CLINIC
CHIEF
SOCIAL
WORK
SERVICE
OIF/OEF
CASE
MANAGER
CORRIDOR
PHARMACY
I.V. ROOM
HOUSE
KEEPING
TOILET
OFFICE
COMM
STAIRWELL
1022 CORRIDOR
CONFERENCE ROOM
CHIEF,
PHARMACY
SERVICE
OPEN OFFICE
PHARMACY
OFFICE
STORAGE
STAIRWELL
S1-2
CORRIDOR
DOCK
CLOSET
ELECT. CLOSET
AGENT
CASHIER
VAULT
MECHANICAL
ELECTRICAL
1600LOCKER'S
POLICE
MEDICAL
ADMIN
OFFICE
MED
ADMIN
OFFICE
DETAILS
CLERK
WOMEN
VETERANS
PROGRAM
MECHANICAL
OFFICE
1227B
STORAGE
1227A
WOMEN
LOCKER
ROOM
CORRIDOR
IT
ELEC
CLOSET
1218A
OFFICE
COMPUTER ROOM
OFFICE
SECR./STOR.
TELE./ELEC.
CORRIDOR
" C.W.
" H.W.
" H.W.C.
" C.W.
1" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
2" C.W.
" C.W. - GALVANIZED
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
2" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.R.C.
RISER STOPS HERE
1" H.W.
" H.W.C.
2" C.W.
" H.W.
" H.W.C.
" C.W.
1" H.W.
" H.W.C.
2" C.W.
RISER
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
" H.W.
" H.W.C.
" C.W.
1" H.W. (CAPPED IN CRAWL)
" H.W.C. (CAPPED IN CRAWL)
2" C.W.
" H.W.
" H.W.C.
RISER STOPS
HERE
2" RISER
" C.W.
" H.W.
" MIXED
FEEDS EYEWASH
44 43
40 39
38 37
36 35
34 33
32 31
13 15
18 20
1 21
22 24
23 25
T O
C
L C
" C.W.
" H.W.
VALVES ARE CLOSED
IN CRAWLSPACE
3" C.W.
RISER
" C.W.
" H.W.
" H.W.C.
RISER STOPS HERE
" C.W.
1" H.W.
SUPPLY TO 2424
SUPPLY TO
1426A FIXTURES
VALVE # CW12
VALVE # HW12
X X
X X
X X
X X
X X
X
X
XXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X
VALVE # CW14
" H.W.
FEEDS
RESTROOM 2005
C.W. VALVE CW2
H.W. VALVE HW2
X
XXXXXXXXXXXXXXXXX
X
XXXXXXXXXXXXXXXXXXXX
C.W. VALVE CW3 - CLOSED
H.W. VALVE HW3 - CLOSED
" LINES FEEDS
SINKS IN 2008, 2007A
" LINES FEEDS
SINK IN 2007A
X X
X X
X X
X X
X X
X X
X X
XXXXXXXX
X X
X
XXXXXX
XXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXX
X X
X
" C.W.
X
H.W. & H.W.C.
CONNECT
FEEDS GROSSING
LAB
" C.W.
" H.W.
" H.W.C.
H.W. & H.W.C.
CONNECTED
FEEDS WOMEN'S
LOCKER ROOM.
" H.W.
" H.W.C.
HW & HWC CONNECT
X
HW & HWC CONNECT
TO 2415
SINK
TO 2416
TOILET
TO 2416
SINK
TO 2420
SINK
FEEDS SINK IN
ROOM 2016
VENDING
FOOD SERVING LINE
HOSE BIB
HOOD WASHDOWN
ICE
MAKER
A
A
A
A
1 1
A
A
A
B
B
HOSE BIB
C
D
E E
Scale: AS SHOWN
W
S
E
N
THESE RECORD DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY
OTHERS. THE DESIGN PROFESSIONAL HAS NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS
OR OMISSIONS WHICH MAY BE INCORPORATED HEREIN AS A RESULT.
RECORD DRAWINGS
NOVEMBER 4, 2016
AutoCAD SHX Text A. REMOVE EXISTING HW AND CW PIPING AS SHOWN. FIELD REMOVE EXISTING HW AND CW PIPING AS SHOWN. FIELD VERIFY THAT PIPING IS ABANDONED PRIOR TO REMOVAL. CAP PIPING AT POINT SHOWN. B. REMOVE EXISTING CW & HW PIPING BACK TO EXISTING REMOVE EXISTING CW & HW PIPING BACK TO EXISTING ISOLATION VALVES AS SHOWN AND CAP. C. REMOVE EXISTING 1-1/2" GALVANIZED CW RISER BETWEEN REMOVE EXISTING 1-1/2" GALVANIZED CW RISER BETWEEN THE BASEMENT AND FIRST FLOOR AND REPLACE WITH NEW 1-1/2" COPPER PIPE. D. REMOVE EXISTING 1-1/2" GALVANIZED CW PIPING IN ITS REMOVE EXISTING 1-1/2" GALVANIZED CW PIPING IN ITS ENTIRETY BETWEEN THE FIRST FLOOR CEILING AND THE SECOND FLOOR AND REPLACE WITH NEW 1-1/2" COPPER PIPE. CONNECT TO EXISTING COPPER PIPING AT EACH END. E. REMOVE EXISTING CONNECTION BETWEEN HW AND HWC REMOVE EXISTING CONNECTION BETWEEN HW AND HWC PIPING. CAP REMAINING TAPS AT HW AND HWC PIPING.
AutoCAD SHX Text
DEMOLITION NOTES:
AutoCAD SHX Text
NEW WORK NOTES:
AutoCAD SHX Text
1. NEW 1/2" HWC PIPING CONNECTED TO EXISTING BRANCH NEW 1/2" HWC PIPING CONNECTED TO EXISTING BRANCH PIPING AS SHOWN. ROUTE TO EXISTING HWC PIPING AND CONNECT.
AutoCAD SHX Text
1/2" HWC
AutoCAD SHX Text
1/2" HWC
AutoCAD SHX Text
1/2" HWC
AutoCAD SHX Text
1/2" HWC
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. FOLLOWING THE REMOVAL OF DESIGNATED ITEMS OR FOLLOWING THE REMOVAL OF DESIGNATED ITEMS OR INSTALLATION OF NEW ITEMS, THE CONTRACTOR SHALL MAKE ANY NECESSARY REPAIRS TO RESTORE AFFECTED AREAS TO MATCH ADJACENT SURFACES TO THE MAXIMUM EXTENT POSSIBLE. THIS INCLUDES, BUT IS NOT LIMITED TO, INSTALLING NEW CEILING TILES TO MATCH EXISTING TILES, RECONFIGURING AND/OR REPLACING SUSPENDED CEILING SUPPORTS AND FRAMES, REPLACING DAMAGED OR MISSING PIPE INSULATION, PATCHING AND PAINTING DAMAGED WALLS, AND ANY OTHER INCIDENTAL WORK REQUIRED TO RESTORE AREAS TO MATCH ADJACENT SURFACES. THIS WORK INCLUDES REPAIRING PENETRATIONS THROUGH SMOKE AND FIRE BARRIERS LEFT OPEN BY REMOVED ITEMS. THESE AREAS SHALL BE REPAIRED TO MEET THE APPLICABLE VA STANDARDS.
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text 575-14-828
AutoCAD SHX Text
AutoCAD SHX Text
VAMC
AutoCAD SHX Text Grand Junction
AutoCAD SHX Text
CO
AutoCAD SHX Text Eliminate Domestic Dead
AutoCAD SHX Text End Water Lines
AutoCAD SHX Text
FIRST FLOOR PLUMBING PLAN
AutoCAD SHX Text P1.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SMN
AutoCAD SHX Text
JLE
AutoCAD SHX Text Jan, 2015
AutoCAD SHX Text
JOHN BARTMAN
AutoCAD SHX Text
PHONE: 970-242-0731
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIRST FLOOR PLAN
AutoCAD SHX Text 3/32" = 1' 0"
AutoCAD SHX Text
RECORD DRAWINGS
STAIRWELL
1411B
TOILET
1426A
1411A
STAIRWELL
COMM
EMPLOYEE
HEALTH
SOC WORK
PROGRAM
Anti-coag
IT ADMIN/
STORAGE
T:Anti-Coag
Pharmacists
E:?
SOC WORK
DAV
E:SW
E:Voluntary Services
WVH Prog
E:Social Work E:DAV E:VBA
E:Volunteers F:CC Reception
Means Means
E:Patient Advocate
E:Soc Wrk F:Patient Advocate
E:Patient Advocate
NON-CLINICAL VETERAN CARE
1606 1604
115 SF 120 SF 116 SF 159 SF 151 SF 195 SF
170 SF
NSF
ROI
117 SFlii ttl e w hi te b oa rd
B ig w hi te b oa rd
E: Pharmacy Waiting Room F:OIT Room
| Colorado Corridor.pdf |
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .