36C25919R0011-0001003.pdf

PDF 854 KB Posted

Attached to
554-19-121 LV01 Power and HVAC in RMR Auditorium (VA-18-00150843)
Solicitation number
36C25919R0011
Issued by

About this file

36C25919R0011 0001 1 - 01_PL_101-D_JSI044.pdf

View the file

Other files

File Type Posted
36C25919R0011-0003001.docx DOCX document
36C25919R0011-0003002.pdf PDF
36C25919R0011-0003000.docx DOCX document
36C25919R0011-0003003.docx DOCX document
36C25919R0011-0002000.docx DOCX document
36C25919R0011-0002001.docx DOCX document
36C25919R0011-0002002.pdf PDF
36C25919R0011-0001002.docx DOCX document
36C25919R0011-0001008.pdf PDF
36C25919R0011-0001009.docx DOCX document
36C25919R0011-0001007.pdf PDF
36C25919R0011-0001004.pdf PDF
36C25919R0011-0001006.pdf PDF
36C25919R0011-0001005.pdf PDF
36C25919R0011-009.pdf PDF
36C25919R0011-007.pdf PDF
36C25919R0011-005.pdf PDF
36C25919R0011-001.docx DOCX document
36C25919R0011-004.pdf PDF
36C25919R0011-006.pdf PDF
36C25919R0011-003.pdf PDF
36C25919R0011-010.docx DOCX document
36C25919R0011-002.pdf PDF
36C25919R0011-008.pdf PDF
36C25919R0011-000.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

UP

DN

UP

01-01-ST3

STAIR

01-01-SE15

ELEV

01-01-ST5

STAIR

01-01-SB30-01

VEST

01-01-A31-03

INFO

01-01-A32-04

SECURITY STOR

01-01-A30-10

LOBBY VEST

01-01-A31-01

OFFICE

01-01-A31-04

SECURITY DESK

01-01-A38-01

DINING

01-01-A37-01

DINING

01-01-A37-04

HAC

01-01-A37-03

VEND/ATM/PHONES

01-01-A37-06

FEMALE TLT

01-01-A37-05

MALE TLT

01-01-A37-02

FAMILY RM

01-01-A36-03

FAMILY TLT

01-01-A36-02

SERVING

01-01-A37-08

NON-FOOD STOR

01-01-A36-01

DINING

01-01-A35-01

DINING

01-01-A34-01

DINING

01-01-A33-01

DINING

01-01-A34-02

VEST

01-01-A34-05

STOR

01-01-A34-04

VEST

01-01-A33-07

STOR01-01-A33-06

STOR

01-01-A33-05

STOR

01-01-A32-08

VEST

01-01-A32-07

W.C. STOR

01-01-A33-08

STOR 01-01-A32-03

VEST 01-01-A33-02

STOR 01-01-A33-03

AV CONTROL

01-01-A33-04

STOR

01-01-A32-05

AUDITORIUM

01-01-A32-01

EXHIB DISPLAY

01-01-A30-01

SEATING

01-01-A30-03

VEND/ATM/PHONES

01-01-A30-09

PUBLIC01-01-A30-04

VEND

01-01-A30-02

HAC

01-01-A30-05

MALE TLT

01-01-A30-06

FEMALE TLT

FINISHED FLOOR

ELEVATION 100.0'

(5388.0' USGS)

8" SW & 8"OFD TO DS

NOZZLE LOCATED AFG. AT

RUNNEL. RE: LANDSCAPE

DWGS. 7,404 SQFT (687.9

SQ METERS)

01.PL.203

01.PL.203

2"FD-S WITH

HALF GRATE

M A T C H L

IN

E A R E A D

M A T C H L

IN

E A R E A E

M A T C H L

IN

E A R E A E

M A T C H L

IN

E A R E A F

6"SW

6"OFD

8"SW

8"OFD

4"SW

4"OFD

6"SW

6"OFD

6"SW

6"OFD

4"SW

4"OFD

4"SW

4"OFD

8"

4"SW UP

TO RD

4"OFD UP

TO OFD

4"SW UP

TO RD

4"OFD UP

TO OFD

4"OFD UP

TO OFD

4"SW UP

TO RD

6"SW UP

TO RD

6"OFD UP

TO OFD

4"OFD UP

TO OFD

4"SW UP

TO RD

4"SW UP

TO RD

4"OFD UP

TO OFD

4"OFD UP

TO OFD

4"SW UP

TO SD

4"SW UP

TO RD

4"OFD UP

TO OFD

6"OFD UP

TO OFD

6"SW UP

TO RD

2"FD

TYPE C

2"FD

TYPE C

2"FD

TYPE C

2"FD

TYPE C

PROVIDE 3"V

DN WALL TO

VENT HEADER

2"V

3"V UP TO 3"VTR

2"V

2"V

PROVIDE 2"V

DN WALL TO

VENT HEADER

PROVIDE 2"V DN WALL

TO VENT HEADER

3"V UP TO 3"VTR

2"V

PROVIDE 2"V DN WALL

TO VENT HEADER

2"V

PROVIDE 2"V

DN WALL TO

VENT HEADER

2"V

2"V

PROVIDE 3"V

DN WALL TO

VENT HEADER

2"WCO

4"FD-S W/

HALF GRATE

4"FD-S W/

HALF GRATE

4"FD-S W/

HALF GRATE

4"FD-S W/

HALF GRATE

3"FD

TYPE C

3"FD

TYPE C

4"V UP TO 4"VTR

2"GV

3"GV

2"V

2"V

4"FCO

2"GV

2"WCO

3"GV

4"FD-S W/

HALF GRATE

P-502

P-609

P-402

P-101

P-102

P-202

P-102

P-102

P-101

P-402

2"W DN2"W

2"W DN

2"W

2"W DN

4"W 2"W

2"W DN

4"W DN

4"W

4"W DN

P-101 P-101

P-402

P-102

P-201

P-202 P-102

P-102

P-102

P-402

P-609

P-502

4"GV

FROM

BELOW

4"V DN & UP

TO 4"VTR

4"SW

4"OFD 4"FD-S W/

HALF GRATE

6"SW

6"OFD

4"SW

4"OFD

3"V DN & UP

TO 3"VTR

1-CUH9

1 - TU4-1

1 - TU10-1

1 - TU10-3

1 - TU10-2

1 - TU6-5

1 - TU7-1

1 - TU6-3

1 - TU6-4

1 - TU6-1

1 - TU6-2

1 - TU7-2

1 - TU7-3

1 - TU7-4

D

D

C

C

B

B

A

A

E

E

A

R1

SB

SB

SC

SC

S29.3

S30 01

S31

SD

SD

S32

S33

S34

S34.6

S35

S36

S37

S38

11.5

A

01-01-A41-01

VEST

01-01-A39-01

PLAY01-01-A38-01

DINING

4" SW TO DS NOZZLE

LOCATED AFG. RE:

LANDSCAPE DWGS. 1,170

SQFT (108.7 SQ METERS)

01.PL.203

6"RD (AT GRADE)

2345 SQ FT

(217.9 SQ METERS)

4"GCO

M A T C H L

IN

E A R E A E

M A T C H L

IN

E A R E A F

4"OFD

4"SW

RE: RESEARCH

PLUMBING DWGS

FOR CONTINUATION.

D

C

B

A

E

A

10-ST3

STAIR

10-SE11

ELEV

A

A

B

B.5

B.7

C

11 12 08 09 13

03040506

Drawing Number

Building Number

Project NumberProject Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

Key Plan

CONSULTANTS:

DateRevisions

1 2 3 4 5 6 7 8 9 10 11 12

D

C

B

A

554-501REPLACEMENT MEDICAL CENTER

FACILITY, EASTERN COLORADO

HEALTH CARE SYSTEM

AURORA, COLORADO

N

C O N

R E S

D A T

I B S

I B N

E N C

C L C

C B N

C B C

C B S

P S N

P V N

P V S

13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

E o n e e ig h th i n c h o n e f o o t

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT/ENGINEERS:

H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202

Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604

Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401

S. A. Miro, Inc.

4582 South Ulster Street Pkwy.

Suite 300 Denver, CO 80237

Professional Seal

/1 /2 :1 :4 A M

D R e v it L o c a l P ro je c ts \2 \P L -I F O -S h e e ts M S w a rt z e n d ru b e r.

rv t

01.PL.101-D

LEVEL 1 WASTE, DRAIN AND VENT

PIPING PLAN - AREA E/F

CONCOURSE

08/31/2012

0' 4' 8' 16' 32'0' 4' 8' 16' 32'

NORTH

FE

DBA C

1/8" = 1'-0"1

LEVEL 1 WASTE, DRAIN AND

VENT PLAN PIPING - AREA E

1/8" = 1'-0"2

LEVEL 1 WASTE, DRAIN AND

VENT PLAN PIPING - AREA F

0' 4' 8' 16' 32'0' 4' 8' 16' 32'

CDI No.12 08/31/2012

JSI No. 044 12/19/2012

Emeka.Nwabunwanne Cloud

Emeka.Nwabunwanne Callout See KT RFI 4059 / VA 3518 for Clarification on Unidentified Millwork Sink Types

Emeka.Nwabunwanne Cloud

Emeka.Nwabunwanne Callout See KT RFI 4059 / VA 3518 for Clarification on Unidentified Millwork Sink Types

Emeka.Nwabunwanne Polygon

Emeka.Nwabunwanne Callout See KT RFI #4279 / VA #4053 for Roof Drain & Downspout Clarification

Xavier.Larsen Callout See RFI KT # 1842 / VA # 1706a regarding the plumbing beam conflict.

VA.PLAN

Cloud

VA.PLAN

Callout RFI #7882: This storm drain line is not constructible. The VA selects the option of draining the area by sloping to the swale. James Chang (COTR) will provide grading directions to KT Superintendent in the field to achieve positive drainage to a proper location.

Any cost associated with this RFI has to be approved through authorization process.

Peter.Bernard Callout Per RFI #7494, see attachment PL.X304 showing addition of (1) 4” Roof Drain and (1) 4” Overflow Drain south of GL 01/33 and the concrete curb/expansion joint assembly.

Peter.Bernard Cloud

Peter.Bernard Callout See RFI #7861a (Follow Up to RFI # 7494) regarding drain line routing through W24x131 beam

Charlie.Stiens Callout See RFI #8952 confirmed no floor drains in family bathrooms.

Evan.Brophy Text Box REFER TO RFI #08293 FOR MATRIX IDENTIFYING RESOLUTION TO AREAS OF CRACKING/DELAMINATION AT TOPPING SLAB SURROUNDING FLOOR DRAINS

Evan.Brophy Cloud

2012-12-17T15:18:28-0700
Dennis F. Rudko