Attch B_Solicitation Work List Unit Pricing Table.pdf
PDF 66 KB Posted
- Attached to
- Y1AA--598-23-106 B65 Structural Repairs-NLR Federal contract opportunity
- Solicitation number
- 36C25625R0087
About this file
This document is a detailed Work List Unit Pricing Table for structural concrete repairs, providing a comprehensive breakdown of 19 distinct work items for a construction project. The work list includes tasks such as shoring existing concrete columns and pilasters, repairing delaminated or spalled concrete surfaces, installing concrete encasements, and providing allowances for supplemental steel and reinforcing work. Estimated quantities range from 1 to 5,300 units across various repair and reinforcement activities, with specific reference details pointing to structural drawings (S-551 through S-553).
The pricing table is part of a solicitation (No. 36C25625R0087) for the Department of Veterans Affairs Veterans Health Administration, specifically for structural repairs at a facility. Key repair activities involve addressing concrete deterioration, including removing damaged concrete, repairing corroded reinforcing steel, installing galvanic anodes, applying anti-carbonation coating, and providing contingency allowances for additional steel installation and concrete repair. The document provides precise descriptions of each work item, including assumed dimensions, repair depths, and specific materials like welded wire mesh and epoxy dowels.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25625R0087 0004.pdf | ||
| 36C25625R0087 0003.pdf | ||
| Attch A_RFIs for Building 65 Structural Repairs 36C25625R0087 - VA Response.pdf | ||
| Attch C_Site Visit Sign In Form - 598-23-106 Building 65 Repairs dtd 5-13-2025.pdf | ||
| 36C25625R0087 0002.docx | DOCX document | |
| 36C25625R0087 0001 Amendment.pdf | ||
| Bldg 65 Structural Repairs Drawings CD 20250131.pdf | ||
| Attachment D -Wage Determination.pdf | ||
| 36C25625R0087 Solicitation_ Completed.pdf | ||
| 36C25625R0087 Site Visit Agenda.docx | DOCX document | |
| Attachment F_EXHIBIT B PERFORMANCE RELEVANCY SURVEY.docx | DOCX document | |
| Attachment E_EXHIBIT A CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY.pdf | ||
| Bldg 65 Structural Repairs Specifications BD 20250131.pdf | ||
| 598-23-106 B65 SOW v20250121.doc | DOC document | |
| 36C25625R0087_1.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESCRIPTION WORK ITEM REFERENCE DETAIL ESTIMATED QUANTITY UNIT PRICE
SHORE EXISTING CONCRETE COLUMNS AND PILASTERS PRIOR TO REPAIRS AT ALL LEVELS. REPLACE OR REPAIR ELEMENTS DAMAGED OR REMOVED IN ORDER TO INSTALL SHORING SUCH AS EXTERIOR WALLS AND INTERIOR FINISHES. INSTALL NEEDLE SHORING AT PERIMETER WALLS AS REQUIRED TO SUPPORT
TRIBUTARY BEAMS.
1A 3/S-551 14 LOCS
SHORE EXISTING CONCRETE COLUMNS PRIOR TO REPAIRS AT THE EAST ENTRACE STAIR FRAMING. 1B 1/S-551 2 LOCS
SHORE FLOOR STRUCTURE UNDER EXISTING ELECTRICAL ROOM. 1C 6/S-551 1 LOC
REPAIR DELAMINATED OR SPALLED OVERHEAD CONCRETE AND CORRODED REINFORCING STEEL ON UNDERSIDE OF CONCRETE JOISTS. FOR PRICING PURPOSES, ASSUME EACH REPAIR LOCATION IS 3 FEET LONG UNLESS NOTED OTHERWISE ON PLAN. ASSUME AVERAGE DEPTH OF CONCRETE REMOVAL TO BE 3
INCHES AND FULL WIDTH OF THE EXISTING JOISTS.
2 2/S-552 250 LF
REPAIR DELAMINATED OR SPALLED OVERHEAD CONCRETE AND CORRODED REINFORCING STEEL ON UNDERSIDE OF CONCRETE BEAMS. FOR PRICING PURPOSES, ASSUME AN AVERAGE DEPTH OF REPAIR TO
BE 4 INCHES.
3 3/S-552 70 SF
REPAIR DELAMINATED OR SPALLED VERTICAL CONCRETE AND CORRODED REINFORCING STEEL ON CONCRETE COLUMNS AND PILASTERS. FOR PRICING PURPOSES, ASSUME AN AVERAGE DEPTH OF REPAIR
TO BE 4 INCHES.
4 5/S-552 275 SF
REPAIR DELAMINATED OR SPALLED VERTICAL CONCRETE AND CORRODED REINFORCING STEEL ON CONCRETE WALLS. FOR PRICING PURPOSES, ASSUME AN AVERAGE DEPTH OF REPAIR TO BE 4 INCHES.
5 6/S-552 650 SF
REPAIR DELAMINATED OR SPALLED OVERHEAD PARTIAL DEPTH CONCRETE AND CORRODED
REINFORCING STEEL ON UNDERSIDE OF CONCRETE PAN JOIST SLAB. ASSUME THAT EXISTING WELDED WIRE MESH WILL REQUIRE REPLACEMENT WITH W4 4x4 WELDED WIRE MESH. FOR PRICING PURPOSES, ASSUME AN AVERAGE DEPTH OF REPAIR TO BE 2 INCHES.
6 1/S-552 50 SF
INSTALL CONCRETE ENCASEMENT AT COLUMNS WITH SEVERELY DETERIORATED REINFORCING STEEL. 7 6/S-553 8 LOCS
INSTALL CONCRETE ENCASEMENT AT PILASTERS WITH SEVERELY DETERIORATED REINFORCING STEEL. 8 6/S-553 13 LOCS
INSTALL SUPPLEMENTAL STEEL POST AT DETERIORATED STAIR COLUMNS. 8.5 4/S-553 2 LOCS ENLARGE EXISTING JOISTS DAMAGED BY PREVIOUS CONCRETE CORING OR CHIPPING AT ENDS OF
JOISTS.
9 1/S-553 14 LOCS
ENLARGE EXISTING JOISTS DAMAGED BY PREVIOUS CONCRETE CORING OR CHIPPING AWAY FROM ENDS
OF JOISTS.
10 2/S-553 6 LOCS
INFILL EXISTING SLAB OPENING. 11 4/S-552 1 LOC
LOCATE AND SEAL EXISTING ABANDONED PIPE PENETRATIONS WITH CONCRETE REPAIR MATERIAL OR
HYDROPHOBIC GROUT PER DETAILS.
9/S-552 10/S-552
50 LOCS
INSTALL GALVANIC ANODES AT PERIMETER OF CONCRETE REPAIR AREAS. FOR PRICING PURPOSES, ASSUME VECTOR CORROSION SERVICES GALVASHIELD XP4 AS BASIS OF DESIGN PRODUCT SPACED @18"
OC.
13 8/S-552 1,600 LOCS
INSTALL ANTI-CARBONATION COATING AT BOTTOM AND SIDES OF ALL EXISTING BEAMS OF THE CRAWL SPACE. FOR PRICING PURPOSES, ASSUME SIKAGARD 670W BY SIKA AS BASIS OF DESIGN PRODUCT.
14 7/S-552 5,300 SF
PROVIDE AN ALLOWANCE FOR REINFORCING STEEL THAT WILL BE INSTALLED WHERE EXISTING
REINFORCING STEEL HAS LOST MORE THAN 10% OF ITS CROSS SECTIONAL AREA.
15 3/S-553 5,000 LBS
PROVIDE AN ALLOWANCE TO REPAIR PARTIAL DEPTH, DETERIORATED OVERHEAD CONCRETE SLAB
SOFFIT UNCOVERED DURING THE REPAIR.
16 1/S-552 1,000 SF
PROVIDE AN ALLOWANCE TO REMOVE AND REPLACE EXISTING INSULATION ADJACENT TO REPAIR AS
NEEDED TO PERFORM WORK.
17 - LUMP SUM
AT CONTRACTOR'S OPTION, PROVIDE AN ALLOWANCE TO INSTALL BAR COUPLERS IN LIEU OF REMOVAL OF SOUND CONCRETE TO INSTALL REINFORCING BARS SPLICED PER REBAR SPLICE LENGTH TABLE. BUILD
OUT CONCRETE REPAIR TO PROVIDE MINIMUM CONCRETE COVER PER CONCRETE COVER TABLE.
18 3/S-553 1,000 LOCS
PROVIDE AN ALLOWANCE TO INSTALL EPOXY DOWELS WHERE SUPPLEMENTAL STEEL CANNOT BE
DEVELOPED. ASSUME DOWELS ARE #5 BARS, 25" LONG WITH 8" EMBEDMENT INTO EXISTING CONCRETE
USING HILTI HIT RE 500V3.
19 - 500 LOCS
ALLOWANCES
WORK LIST