This document appears to be a floor plan for the 09-Q Administration building of the Southeast Louisiana Veterans Health Care System (SLVHCS) in New Orleans, Louisiana. The plan shows the layout of the first floor and basement level, including room numbers, names, and uses. The key areas include an auditorium, conference rooms, IT classrooms, a credit union, and administrative and support spaces. This document does not appear to contain information about a federal contract opportunity. The related federal contract opportunity solicitation is for Project #629-18-114 to expand the Distributed Antenna System at the SLVHCS, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB), newest first.
File Type Posted
INTERSTITIAL LEVEL 4i AREA F1.1_recover-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA E2-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA F1.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA D2.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA E1-Model.pdf PDF
INTERSTITIAL LEVEL 4i AREA G1.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2-Model.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2.1-Model.pdf PDF
INTERSTITIAL LEVEL 2i AREA F1-Model.pdf PDF
LARGE SECOND FLOOR.pdf PDF
LARGE FOURTH FLOOR.pdf PDF
LARGE EIGHTH FLOOR.pdf PDF
01.BC.pdf PDF
06.M.pdf PDF
FIRST FLOOR.pdf PDF
03.HJ.pdf PDF
THIRD FLOOR-LIFE SAFETY.pdf PDF
01-BC INPATIENT - LVL.1-01.BC.1.pdf PDF
RESEARCH-FIFTH FLOOR -LIFE SAFETY.pdf PDF
FOURTH FLOOR.pdf PDF
05.L.pdf PDF
01-BC INPATIENT - LVL.5-01.5.pdf PDF
05.SUM.pdf PDF
04-K STAFF PARKING - LVL.7-04.K.7 L.S..pdf PDF
LEVEL 3.5-LIFE SAFETY.pdf PDF
01-BC INPATIENT - LVL.6-01.BC.6.pdf PDF
36C25624R0010 A0001 REVISED-6TH LEVEL -PATIENT GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-5TH LEVEL -STAFF GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-4TH LEVEL -STAFF GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-3RD LEVEL -STAFF GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-1ST LEVEL -PATIENT GARAGE.pdf PDF
36C25624R0010 A0001 NOR-CC-02AR.pdf PDF
36C25624R0010 A0001 NOR-09-01AR.pdf PDF
36C25624R0010 A0001 NOR-08-04AR.pdf PDF
36C25624R0010 A0001 NOR-08-02AR.pdf PDF
36C25624R0010 A0001 NOR-07-04AR.pdf PDF
36C25624R0010 A0001 FISHER HOUSE -SECOND FLOOR-Model.pdf PDF
36C25624R0010 A0001 NOR-06-04AR.pdf PDF
36C25624R0010 A0001 NOR-03-08AR.pdf PDF
36C25624R0010 A0001 NOR-03-07AR.pdf PDF
36C25624R0010 A0001 NOR-03-05AR.pdf PDF
36C25624R0010 A0001 NOR-03-02AR.pdf PDF
36C25624R0010 A0001 NOR-02-04AR.pdf PDF
36C25624R0010 A0001 NOR-01-05AR.pdf PDF
Att 15 - DAS - Wire Mesh Partitions.docx DOCX document
Att 10 - DAS - Reference Standards.docx DOCX document
Att 8 - DAS - HEFP SEP Design Alert 12 - Design Submission Guidance for Telecommunications.pdf PDF
36C25624R0010 EXHIBIT D.docx DOCX document
Att 13 - DAS - Scope of Existing.docx DOCX document
Att 12 - DAS - Schedules.docx DOCX document
Show all 50

Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Issue

DateProject:

Building/Wing.

Client Project No.

AutoCAD File Name

Title Drawn by: Checked by: Date:

Location Scale:

RAM AJA

For Review

Facility:

09-Q ADMINISTRATION

SLVHCS LSC EVAL - 2017Life Safety Audit 2017 06-01-1706-01-17 Southeast Louisiana Veterans Health Care System 2400 Canal Street New Orleans, LA 70119

(800) 935-8387 SLVHCS, LA

The Mihalik Group 1300 West Belmont Ave., Suite 500 Chicago, Illinois 60657

(773) 929-4276

PLAN

NORTH

REFERENCE PLAN

D

E

F

G

B1

C1

M1 M2

H

J1

J2

N1

N2

B2

C2

Q

K

L

P

A

M3

09-Q ADMIN.-LVL. B & 1

BUILDING

NUMBER

BUILDING

AREA

Revision 07/22/2020

SIM LAB

1Q128

CLASSROOM

1Q127

CLASSROOM

1Q126

TELECOM

DEMARCATION

1Q125

ELEC

1Q124

LVSR

1Q129A

MANAGER

1Q130D

WRKSTN

1Q130E

SUPPLIES

1Q130C

VAULT

1Q130B

SUPPLIES

1Q121

SUPERVISOR LOAN OFFICER

SERVICE

WINDOW

1Q130A

FEMALE

1Q123 MALE

1Q102

SUPPLIES

1Q104

IT SUPPLIES

1Q105

IT CLASSRM

1Q106

ACOS

1Q107A

ASST./ WAITING

1Q107

OFFICE

1Q101B

CLASSROOM

1Q101C

CHILLED

WATER PUMP

1Q103

CAFE

1Q109

PANTRY

1Q110

MALE

1Q112

CONF

1Q113

AUDITORIUM

1Q115

FEMALE

1Q118

ELEC./AV

1Q119

ADMIN.

1Q101A

IT CLASSRM

1Q108

LOBBY

1Q100

LOBBY

1Q130

CORR

1QC05

PREFUNCTION

SPACE

1Q116A

PREFUNCTION

SPACE

1Q114A

HK

1Q111

CORR

1QC03

CONF

1Q114

CONF

1Q116

CONF

1Q117

LIBRARY

1Q101

CHAIRS

1Q120

TELECOM

1Q129

EMER ELEC

1Q124A

ELEV LOBBY

1Q100A

ATM

1Q127

CAFE WRKRM

1Q109A

CORR

1QC06

PREFUNCTION

SPACE

1Q117A

PREFUNCTION

SPACE

1Q113A

DN

UP

DN

UP

STAIR

1STQ1

STAIR

1STQ2

ELEV

QP-1

ELEV

QP-3

ELEV

QP-2

TELEPHONE

EQUIP.

1Q122

STAIR

1STQ4

STAIR

1STQ3

1Q130F 1Q130G

PATIO

H

F H

F H

F

H F

H

F

H F

H

F H

F

2HF2HF2HF

H

F

H F

H

F

H F

H

F H

F H

F

H F

2HF 2HF 2HF

H

F

2HF 2HF 2HF 2HF

H

F

H F

H

F H

F H

F

H F

H

F

H F

H

F

2HF

2HF2HF2HF

H

F

H F

H

F H

F H

F

H F

H

F

H F

H

F

2HF

2HF

H

F H

F

H F

H

F

H F

H

F H

F H

F

2HF

H

F

H F

H

F

H F

H

F H

F H

F

H F

2HF

STPSTPSTPSTP

S T

P S

T P

S T

P S

T P

S T

P

STP STP STP STP STP STP

S T

P S

T P

S T

P S

T P

S T

P

H

F H

F H

F

H F

H

F

H F

H

F H

F

2HF 2HF 2HF

H

F

H F

H

F

H F

H

F H

F H

F

H F

2HF2HF2HF

H

F

2HF2HF2HF2HF

H

F

H F

H

F

H F

H

F H

F

H F

H

F

H

F

2HF

2HF 2HF 2HF

H

F H

F

H F

H

F

H F

2HF

H

F H

F

H F

H

F

H F

H

F H

F H

F

2HF

H

F

H F

H

F

H F

H

F H

F H

F H

F

2HF

2HF 2HF 2HF

H

F

2HF2HF2HF

H

F H

F H

F H

F

1HF 1HF 1HF 1HF 1HF 1HF 1HF 1HF 1HF 1HF 1HF 1HF 1HF

H

F H

F H

F H

F H

F H

F H

F H

F H

F H

F H

F H

F H

F H

F H

F

1HF1HF1HF1HF1HF

STP STP STP STP STP

S T

P S

T P

S T

P S

T P

S T

P

S T

P

STPSTPSTPSTP

S T

P

STP STP STP STP STP STP STP STP STP STP STP

S T

P S

T P

S T

P S

T P

S T

P S

T P

S T

P

STPSTPSTPSTPSTPSTPSTPSTPSTPSTPSTP

H

F H

F

H F

H

F H

F H

F H

F

2HF2HF2HF2HF

H

F

H F

H

F

H F

H

F H

F H

F

2HF 2HF 2HF 2HF

2HF 2HF 2HF 2HF

H

F H

F

H F

H

F H

F H

F H

F

2HF2HF2HF2HF

H

F

H F

H

F

H F

H

F H

F H

F

2HF 2HF 2HF 2HF

2HF 2HF 2HF 2HF

STQ

STQ

QP-1

ELEV.

QP-3

ELEV.

QP-2

ELEV.

STQ

STQ

AUDITORIUM

CONF.

CONF.

CONF.

CONF.

CAFE

LIBRARY

IT

EDUCATION

CREDIT

UNION

EDUCATION

SIM

LAB

ZONE

1Q.1

BUSINESS

CORR

1QC01A

COOR

1QC04A

CORR

1QC02A

CORR

1QC02

CORR

1QC01

COOR

1QC04

PAN AM

CONNECTOR

1D200

CORR87

971SF

1Q-C04A1

B

STB

S.C.

1B.1

BUSINESS

OVERSIZED DOOR KICK PLATES

12-26-18

5/22/19

09.Q.B-1LIFE SAFETY DRAWINGS

1/16"=1'-0"

1HF 1HF

PARTITION LEGEND

1HFS

2HF 2HF

2HFS

STP STP

SCALE: 1/8" = 1'-0"

- CALCULATION AND LIFE SAFETY PLAN

Basement Level & One Life Safety Plan

LIFE SAFETY SYMBOLS LEGEND

COMPARTMENT CALCULATIONS

CORRIDORS AND STAIRS NUMBER

CHANGED PLUS PAN AM CONNECTOR

BUILDING 09 - Q ADMINISTRATION- FIRST FLOOR

File details come from the government source that posted it. Updated .