06-M TRANSITIONAL - LVL.3 & 4-06.M.3-4 (1).pdf
PDF 834 KB Posted
- Attached to
- Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB) Federal contract opportunity
- Solicitation number
- 36C25624R0010
About this file
This document appears to be a life safety plan for a transitional living facility at the Southeast Louisiana Veterans Health Care System in New Orleans, Louisiana. The plan provides detailed floor plans for Levels 3 and 4 of the building, including room layouts, fire safety features, and compartment calculations. It does not appear to be directly related to the federal contract opportunity provided.
The federal contract opportunity is for a solicitation to expand the distributed antenna system at a Veterans Affairs facility. The solicitation number is 36C25624R0010, and the project is identified as Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB). The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. No additional details about the required products or services, response dates, pricing, or set asides are provided in the information given.
View the file
Other files for this federal contract opportunity
Show all 50
Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Issue
DateProject:
Building/Wing.
Client Project No.
AutoCAD File Name
Title Drawn by: Checked by: Date:
Location Scale:
RAM AJA
Facility:
06-M TRANSITIONAL LIVING
SLVHCS LSC EVAL - 2017Life Safety Audit 2017 Southeast Louisiana Veterans Health Care System 2400 Canal Street New Orleans, LA 70119
(800) 935-8387 SLVHCS, LA
The Mihalik Group 1300 West Belmont Ave., Suite 500 Chicago, Illinois 60657
(773) 929-4276
PLAN
NORTH
REFERENCE PLAN
D
E
F
G
B1
C1
M1 M2
H
J1
J2
N1
N2
B2
C2
Q
K
L
P
A
M3
06-M TRANSITIONAL
LIVING-LVL. 3 & 4
BUILDING
NUMBER
BUILDING
AREA
06-17-1706-01-17 Revision
07/22/2020
MP-2
ELEV.
MP-1
ELEV.
M1
STC
M2
STC
MS-3
ELEV.
LIVING/DINING
QUIET/
DEN
ASST.
MANG.
PANTRY
MULTI-PUR
ON
CALL
ROOM
LOUNGE/
LOCKERS
MECH
ROOM
TR
T
PATPAT
T
T T
PAT
PAT
PAT
PAT
T
PAT
T
NORM
ELEC
VT
MEDS
CLEAN
LINEN
LAUN
ACAD
WKRM
CG
BAR T
T
BAR
PAT
ISO
PAT
SERV
ELEV
LOBBY
ST
T/SHWR
CLEAN
EQUIP
MS-03
3M042
ST
NOUR
CORR
WC
ALC B
PASS
HK
LVSR
T
UP
DN
3M232
3M109
3M234
3M111
3M254
3M236
3M240
3M250
3M248
3M112 3M114
3M253
3M251
3M251A
3M249
3M247
3M242 3M249A
3M245 3M2433M2413M239
3M245A3M243A
3M241A 3M239A
T
3M237 3M2353M233
3M237A
3M235A
3M233A
3M238
3M244
3M252
3M115
3M122
3M120
3M130
3M116
3M115A
3M120A
3N120B
3M122A
3M
2B
3M.C07A
3M.C08
3M.C08A
3M.C09
3M.C08B
OUTDOOR
TERRACE
MULTI-PUR
PANTRY
LIVING/DINING
CARE
TEAM
QUIET/
DEN
OPEN TO BELOW
NORM
ELEC
EMER
ELEC
MEDS
CLEAN
LINEN
VT
LAUN
NOUR
HK
CG
PAT
BAR
PAT
T T
BAR T
PAT PAT PAT PAT PAT
T T T
T T
T
PAT
PAT
PAT
T
T
ISO
PAT
OPEN TO COURTYARDS
BELOW
CLEAN
ST
SOIL
MP-01
3M005A
WC
ALC B
EQUIP
OPEN TO
BELOW
FOOD
PREP
VT
OUTDOOR
TERRACE
OUTDOOR
TERRACE
MP-02
3M005B
TR/
LSVR
ROOM
DN
UP
3M211 3M213
3M215 3M219
3M217
3M221 3M223
3M229
3M2273M225 3M231
3M101
3M205
3M209 3M207
3M204
3M218
3M216
3M203
3M201
3M202
3M102
3M.C01A
3M104
3M106
3M200
3M101A
3M211A
3M213A
3M215A 3M217A
3M219A 3M221A 3M225A
3M223A 3M227A 3M229A
3M105
3M107
3M224
3M220
3M222
3M108
3M226
3M.C02A
3M230
H
F H
F
2HF2HF2HF2HF
H
F H
F
2HF 2HF 2HF 2HF
2HF
H
F
H
F
H F
H
F
H F
H
F
H
F H
F
2HF 2HF 2HF 2HF
H
F
H F
H
F
2HF2HF2HF2HF
H
F
2HF 2HF 2HF 2HF
2HF2HF2HF2HF
H
F
2HF
H
F
H F
H
F
2HF2HF2HF2HF2HF
2HF
2HF
2HF
2HF
2HF
2HF
2HF 2HF 2HF
H
F H
F
H
F H
F
1HF1HF
H
F H
F H
F H
F H
F H
F H
F
H
F H
F H
F H
F
1HF1HF1HF
H
F H
F H
F
1HF 1HF 1HF
H
F H
F H
F H
F
1HF1HF
H
F H
F H
F H
F
1HF 1HF
H
F H
F
1HF 1HF
H
F H
F H
F
1HF
H
F H
F H
F H
F
1HF
H
F H
F H
F H
F H
F H
F
1HF1HF1HF
H
F H
F H
F H
F H
F H
F
1HF 1HF 1HF
H
F H
F H
F
1HF 1HF
H
F H
F H
F
1HF1HF1HF
1HF
H
F H
F
1HF 1HF 1HF 1HF
1HF1HF
2HFS 2HFS
H
F S
2HFS
H
F S
H
F S
2HF2HF2HF
2HF
H
F
H F
H
F H
F H
F H
F H
F
HOUSE A HOUSE B
ADMIN
EXTERIOR
COURTYARD
EXTERIOR
COURTYARD
S.C.
3M.1
HEALTHCARE
M1 M2
S.C.
3M.2
HEALTHCARE
T.D.=23'
T D
T.D.=143'-3"
T.D.=140'-0"
T.D.=150'-0"
T .D
'-0
T.D.=25'
T.D.=18'
S T
P
STP STP STP
STP STP
S T
P
STP STP STP STP STP STP
T.D.=49'-2"
VEST
CORR
STAIR
M2
CORR
CORR
PASS
3M.C06A
3M.C07
3M.C08
3M.C05
3M.C09
CORR
VEST
STAIR
M1
CORR
CORR
3M.C02
3M.C01
3M.C03
3M.C04
CORR
3M.C01B
CORR
3M.C01C
CORR
3M.C01F
CORR
3M.C01G
CORR
3M.C01E
CORR
3M.C01D
CORR
3M.C07B
3STM1
3M.C08A1
AZELEA
CORR
CORR
3M.C06
3STM2
3M.C03A
M2
M2
STC
MS-3
ELEV.
EMER
ELEC
ROOM
WET
MECH
ELEC
SWITCHGEAR
RESIDENT
STOR
HK
STOR
CENTRAL
STOR
CART
STAGING
TR
FOOD
PREP
BRIDGE CONNECTION TO
4TH FLOOR CONCOURSE
MS-03
4M013
VEST
CLEAN
STAG
LVSR
GENERAL
STORAGE
4M119
4M116
4M117
4M115
4M113
4M114
4M105
4M111
4M111A
4M107
4M101
4M103
4M104
4M116A
H
F H
F
2HF2HF2HF2HF
H
F
H F
2HF2HF2HF2HF
2HF2HF
H
F
H F
2HF 2HF
H
F H
F
2HF2HF2HF2HF2HF2HF2HF2HF2HF
H
F
H
F
H F
H
F H
F
2HF2HF2HF2HF2HF2HF2HF2HF2HF2HF
H
F H
F H
F H
F
1HF 1HF
H
F H
F H
F H
F
1HF1HF
H
F
H F
H
F H
F
H F
H
F
H F
2HF 2HF 2HF
2HF 2HF 2HF 2HF
H
F
H
F
2HF
H
F S
BLDG
SUPPORT
BLDG
SUPPORT
ROOF
EXTERIOR
COURTYARD
S.C.
4M.2
STOR/MECH
T D
T D
T
D
T.D.=81'-10"
CORR
B
CORR
B
STAIR
M2
4M.C02
4M.C01
4STM2
CORR
4M.C02A
STAFF
ELEV
LOBBY
4M.C01A
CORR
4M.C02B
CORR
4M.C02C
CORR
4M.C01B
B
STB
S.C.
1B.1
BUSINESS
OVERSIZED DOOR KICK PLATES
12-26-18
5/22/19
SCALE: 1/16" = 1'-0"
0'
8' 16' 32'
PARTIAL LEVEL THREE - CALCULATION AND LIFE SAFETY PLAN
06.M.3-4LIFE SAFETY DRAWINGS
1/16"=1'-0"
1HF 1HF
PARTITION LEGEND
1HFS
2HF 2HF
2HFS
STP STP
PARTIAL LEVEL FOUR - CALCULATION AND LIFE SAFETY PLAN
SCALE: 1/16" = 1'-0"
BUILDING 06 - M TRANSITIONAL LIVING
BUILDING 06 - M TRANSITIONAL LIVING
Level Three & Four Life Safety Plan
LIFE SAFETY SYMBOLS LEGEND
COMPARTMENT CALCULATIONS
COMPARTMENT CALCULATIONS
HAZARDOUS STORAGE
CORRIDORS AND STAIRS NUMBER
CHANGED
09/18/19
File details come from the government source that posted it. Updated .