07-N CEP - LVL.3 & 3.5-07.N.3-3.5.pdf

PDF 395 KB Posted

Attached to
Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB)
Solicitation number
36C25624R0010
Issued by

About this file

This document appears to be a set of construction drawings for the Central Energy Plant (CEP) Levels 3 and 3.5 at the Southeast Louisiana Veterans Health Care System facility. The drawings provide a detailed floor plan layout, including mechanical rooms, electrical rooms, treatment plant, and other support spaces. The drawings are part of a life safety audit and assessment for the facility.

The related federal contract opportunity is for Project #629-18-114 to expand the Distributed Antenna System (DAS) at the facility. This is a solicitation issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 16. The solicitation number is 36C25624R0010, but the document provided does not contain details on requirements, response dates, award information, pricing terms, or set asides. This appears to be a separate facility infrastructure project not directly related to the DAS expansion contract opportunity.

View the file

Other files

File Type Posted
03-HJ OUTPATIENT - LVL.7 & 8-03.HJ.7-8.pdf PDF
01-BC INPATIENT - LVL.4-01.BC.4.pdf PDF
INTERSTITIAL LEVEL 4i AREA E1-Model.pdf PDF
00-A CONCOURSE - LVL.2-00.AX-2 L.S..pdf PDF
09.Q.pdf PDF
THIRD FLOOR.pdf PDF
03-HJ OUTPATIENT - LVL.1-03.HJ.1.pdf PDF
01-BC INPATIENT - LVL.3-01.BC.3.pdf PDF
RESEARCH -LEVEL 5.5-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA D1.1-Model.pdf PDF
06.SUM.pdf PDF
09.SUM.pdf PDF
07.N.SUM.pdf PDF
FOURTH FLOOR-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA E1-Model.pdf PDF
01.BC.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2.1-Model.pdf PDF
01-BC INPATIENT - LVL.5-01.5.pdf PDF
INTERSTITIAL LEVEL 3i AREA G1-Model.pdf PDF
06.M.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2.1-Model.pdf PDF
LARGE FIFTH FLOOR.pdf PDF
LARGE SIXTH FLOOR.pdf PDF
AC.0.pdf PDF
SECOND FLOOR -LIFE SAFETY.pdf PDF
SECOND FLOOR.pdf PDF
00-A CONCOURSE - LVL.4-00.AX-4 L.S..pdf PDF
INTERSTITIAL LEVEL 4i AREA G2.1-Model.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2-Model.pdf PDF
01.SUM.pdf PDF
03-HJ OUTPATIENT - LVL.4-03.HJ.4.pdf PDF
09-Q ADMIN - LVL.2, 3, 4, 5 & 6-09.Q.2-6.pdf PDF
INTERSTITIAL LEVEL 2i AREA F1-Model.pdf PDF
FOURTH FLOOR.pdf PDF
FIRST FLOOR.pdf PDF
04-K STAFF PARKING - LVL.7-04.K.7 L.S..pdf PDF
01-BC INPATIENT - LVL.6-01.BC.6.pdf PDF
LEVEL 3.5-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA D1-Model.pdf PDF
05.L.pdf PDF
INTERSTITIAL LEVEL 3i AREA D2.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA E2-Model.pdf PDF
05.SUM.pdf PDF
LARGE FOURTH FLOOR.pdf PDF
06-M TRANSITIONAL - LVL.3 & 4-06.M.3-4 (1).pdf PDF
00-A CONCOURSE - LVL.4I-00.AX-4I L.S..pdf PDF
09-Q ADMIN -.BASEMENT.pdf PDF
06-M TRANSITIONAL - LVL.1 & 2-06.M.1-2 (1).pdf PDF
00-A CONCOURSE - LVL.3-00.AX-3 L.S..pdf PDF
Show 40 more

Latest 50 of 193 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Issue

DateProject:

Building/Wing.

Client Project No.

AutoCAD File Name

Title Drawn by: Checked by: Date:

Location Scale:

RAM AJA

For Review

Facility:

07-N CENTRAL ENERGY PLANT

SLVHCS LSC EVAL - 2017Life Safety Audit 2017 Southeast Louisiana Veterans Health Care System 2400 Canal Street New Orleans, LA 70119

(800) 935-8387 SLVHCS, LA

The Mihalik Group 1300 West Belmont Ave., Suite 500 Chicago, Illinois 60657

(773) 929-4276

PLAN

NORTH

REFERENCE PLAN

D

E

F

G

B1

C1

M1 M2

H

J1

J2

N1

N2

B2

C2

Q

K

L

P

A

M3

07- N CENTRAL ENERGY

PLANT (CEP)-LVL. 3 & 3.5

06-01-1706-01-17 Revision

07/23/2020

B

STB

S.C.

1B.1

BUSINESS

OVERSIZED DOOR KICK PLATES

12-26-18

5/22/19

3N115

SERVICE

BAY

REF

LIB

PLANS,

DRAFTING,

WORK

OFFICE

STOR/OFF

CHIEF

OF

SERV

OPS

ENG

ASST

CHIEF

PROJ

ENG

PROJ

ENG

PROJ

ENG

CONF

CLERK/REC

WAITING

3N109

TELECOM

LOUNGE

ELEC

SHN103

INTERIOR

DESIGNERS

KITCHEN

SECURITY

CHUTE

FAN

ROOM

FAN

ROOM

ELEVATOR

SHAFT

HK

TOILET

TOILET

STAIR

3STN3

SHAFT

3.5N145

3N1013N103

3N105

3N107

3N107A

3N109A

3N109B

3N109M

3N111

3N109L

3N109K

3N109I

3N109C

3N109D

3N109E

3N109F

3N109G

3N109H

3N109J

3N113

3N117

3N117A

3N114

STAIR

3STN2

3N109J3

3N109J1

3N109J2

3N109B3

3N109B2

3N109B.1

STN

STN

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F H

F H

F

H F

H

F H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H F

H

F H

F H

F H

F H

F

H F

H

F H

F

2HF2HF2HF2HF2HF2HF2HF

2HF2HF2HF2HF2HF

H

F H

F H

F

H

F H

F H

F H

F

2HF

H

F H

F H

F H

F

T

D

N

S.C.

7N.3

MECHANICAL

FACILITIES REFER TO

07 - N - LEVEL 3.5

REFER TO

07 - N - LEVEL 3.5

REFER TO

07 - N - LEVEL 3.5

CEP

CORR

3NC03A

CORR

3NC05A

CORR

3NC06

CORR

3NC04

CORR

3NC05

CORRIDOR

3NC02.A

CORR

3NC03

CUBICLE AREA

CUBICLE AREA

3NCO3.1 TO 3NC03.4

3NC05.1 TO 3NC05.4

CORR

LOBBY

3NC01

3NC02

CORR

3NC07

CORR

3NC08

UP

DN

UP

DN

DN

DN

2HF 2HF

H

F H

F

H F

H

F

2HF2HF2HF2HF2HF2HF2HF

H

F

H F

H

F

2HF 2HF 2HF 2HF 2HF

H

F

H F

H

F H

F

H

F H

F

H F

H

F

H

F H

F H

F

2HF

H

F H

F H

F

2HF

2HF

H

F H

F

H F

H

F

H F

H

F

H

F

H F

H

F H

F

H F

H

F

H F

H

F H

F H

F

H F

2HF 2HF

H

F

H

F

2HF

H

F H

F H

F

H F

H

F

H F

H

F H

F

2HF 2HF

2HF 2HF 2HF 2HF 2HF 2HF 2HF 2HF 2HF 2HF 2HF 2HF 2HF

2HF2HF

2HF

H

F H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F

H

F H

F H

F

ELEVATOR

SHAFT

CHILLERS/

PUMPS

3N124

ELECTRICAL

CHILLER

SWITCHGEAR

3N124A

EMERGENCY

ELECTRIC

3N126

CHILLERS/

PUMPS

3N124B

SHAFT

BOILER PLANT

CONTROL

3N122

SHAFT

TREATMENT

PLANT

HK

TOILET

TOILET

3N120

3N120C

3N120B

3N120A

TREATMENT

PLANT

3N120

STN

STN

SHAFT

3.5N145

T.D.=285-5"

N

S.C.

7N.3.5

MECHANICAL

FACILITIES

CEP

REFER TO

07 - N - LEVEL 3

REFER TO

07 - N - LEVEL 3

CHILLERSTREATMENT

PLANT

STAIR

3.5STN1

3NC09

CORR

CORR

3NC10

CORR

3NC11

CORR

3NC12

CORR

3NC12A

CORR

CORR

CORR

07.N.3-3.5LIFE SAFETY DRAWINGS

1/16"=1'-0"

SCALE: 1/16" = 1'-0"

0'

8' 16' 32'

PARTIAL LEVEL THREE - LIFE SAFETY PLAN

BUILDING 07 - N - CENTRAL ENERGY PLANT (CEP)

SCALE: 1/16" = 1'-0"

PARTIAL LEVEL THREE AND A HALF - LIFE SAFETY PLAN

3.5 BUILDING 07 - N CENTRAL ENERGY PLANT (CEP)

LIFE SAFETY SYMBOLS LEGEND

COMPARTMENT CALCULATIONS

1HF 1HF

PARTITION LEGEND

1HFS

2HF 2HF

2HFS

STP STP

CORRIDORS AND STAIRS NUMBER

CHANGED

File details come from the government source that posted it. Updated .