FOURTH FLOOR-LIFE SAFETY.pdf
PDF 622 KB Posted
- Solicitation number
- 36C25624R0010
About this file
This document appears to be a life safety plan for Building 08 of a Veterans Affairs medical center project in New Orleans, Louisiana. The plan provides detailed information on the building's construction type, occupancy, exit capacities, and maximum travel distances. It includes a floor plan that shows the locations of various rooms, corridors, elevators, and fire protection equipment such as fire extinguishers and standpipes. The plan also includes notes referencing additional analysis and details provided in the fire protection and life safety analysis narrative. Overall, this document outlines the key life safety design elements for the new medical center building.
View the file
Other files
Show 40 more
Latest 50 of 193 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
204'
106'
122' F
F
F
F
F
F
2-HR ELECTRICAL
RISER SHAFTS
170 160
LABORATORY UNIT 4A
19'
S
S
HK
4P319
FEC-W FEC-W
FEC
4P-C05B
CORR
4P171
66 S.F
139 S.F
J
E
E
P
3/4
CM
CM
P
CM
CM
DH
R
DH
E
15 15 15 15 15
151515
75 75
FACP8-2
WP
WP
WP
WP
WP
WP
TO
SECURITY
FOR
DOOR
RELEASE
TO
SECURITY
FOR
DOOR
RELEASE
TO
SECURITY
FOR
DOOR
RELEASE
ELSR824-1
30 30
DN
UP
UP
UP
HOLD
4P327
TREAT
4P329
HOLD
RABBIT
4P331
TREAT
4P333
HOLD
RABBIT
4P335
ELEC
4P115B
HK
4P113
REF:1P104
HOLD
4P302A
HOLD
4P323
TREAT
4P321
HOLD
4P317
HOLD
4P324
TREAT
4P322
ISO
HOLDING
ANTE-ROOM
4P320A
HOLD
4P316
OR
SUP
4P318D
OR
4P318C
GOWN
PREP
4P318B
FEED
& BED
STOR
4P314B
CLEAN
CAGE
4P314A
CLEAN
CAGE
WASH
4P314
SOIL
CAGE
WASH
4P304
WOMEN
LOCKER
4P300F
VET
OFF
4P300B
LOUNGE
4P300
OFF
4P300A
MEN
LOCKER
4P300C
HAZ
WASTE
STOR
4P303
WALK- IN
FREEZER
4P305
TELECOM RM.
4P103
WATER
SYS
4P311
CARC
HOLD
4P309
NECRO
4P307
EQUIP
4P305A
UNASSIGNED
4P315
ENVIRO
PROC
4P313A
ENV
HOLD
4P313
ELEC
4P301
TL
4P104
TL
4P102
REC +
W
4P101
RECPT
4P100
X RAY
4P318A
UNASSIGNED
4P100A
HK
4P319
QUAR
HOLD
4P302B
DIAG
HOLD
4P302C
CORR
4PC03A
CORR
4P-C03B
CORR
4PC01
CORR
4PC02
ELEV
PS-01
ELEV
PS-02
4P102A 4P105A 4P101A
4P103A
T/S
4P300E
T/S
4P300D
VESTIBULE
4P-C01D
VESTIBULE
4PC03C
UNAS
4P106A
VESTIBULE
4P115A
FEC-W FEC-W
FEC
FEC
FEC
ISO
HOLDING
4P320B
RCO
4P200
AO
4P201
CORR
4PCO1B
ELEV.
LOBBY/CORRIDOR
4.5PC20
LVSR
4P103B
CORR
CORR
CORR
4PC05
4PC06
4PC05B
4PC04
4PC04A
4PC04B
4PC04C
CORR
CORR
CORR
CORR
CORR
4PC05A
4P189
456 S.F
4P190
432 S.F
4P178
99 S.F
4P180A
205 S.F
4P176
212 S.F
4P174A
198 S.F
4P174
215 S.F
4P170
412 S.F
4P187
217 S.F
4P185
218 S.F
4P188
206 S.F
4P180
97 S.F
4P172
205 S.F
4P168
205 S.F
4P170A
700 S.F
4P166
1017 S.F
4P160
218 S.F
4P162
109 S.F
4P156
126 S.F
4P154
123 S.F
4P152
119 S.F
4P156A
66 S.F
4P158A
66 S.F
4P150
110 S.F
4P158
127 S.F
4P164
108 S.F
4P202
134 S.F
4P101
237 S.F
4P200
128 S.F
4P151
146 S.F
4P153
112 S.F
4P157
219 S.F
4P159
197 S.F
4P161
197 S.F
4P163A
95 S.F
4P163
95 S.F
4P100
349 S.F
4P165
199 S.F
4P104
145 S.F
4P102
67 S.F
4P155
101 S.F
4P103
241 S.F
4P105
252 S.F
4P107
101 S.F
4P109
115 S.F
4P111
115 S.F
4P113
115 S.F
4P115
115 S.F
4P167
1268 S.F
4P169
418 S.F
4P171
66 S.F
4P173
197 S.F
4P175
404 S.F
4P121
107 S.F
4P123
115 S.F
4P123A
96 S.F
4P181
208 S.F
4P183
210 S.F
4P204.1
4P204.2
4P204.4
4P204.3
4PC01C
326 S.F
4P204.5
4P204A
172 S.F
4P117
593 S.F
FILE/COPY
4P203
OFFICE
4P202E
OFFICE
4P202C
OFFICE
4P202D
OFFICE
4P202E
OFFICE
4P202B
ACOS
OFFICE
4P202A
CONFERENCE
ROOM
4P204
4P206
276 S.F
4P204
CUB
SPACE
1080 S.F
CORR
4P-CO1
4P208
153 S.F
568 S.F
880 S.F
105 S.F
212 S.F
231 S.F
187 S.F
219 S.F
923 S.F
122 S.F
350 S.F
242 S.F
308 S.F 372 S.F
66 S.F
139 S.F
63 S.F
CORR
4PC02A
289 S.F
CORR
4PC01A
46 S.F
4P202
STAIR
4STP2
STAIR
4.5STP1
STP-2
STP-1
HEALTH STUDIES HEALTH STUDIES HEALTH STUDIES HEALTH STUDIES
S S S S S
S S S S S
S S S
F
SMOKE PARTITION
GLASS/SPRINKLER 2-HOUR ASSEMBLY (DOUBLE LINE)
GLASS/SPRINKLER 1-HOUR ASSEMBLY (SINGLE LINE)
1-HOUR RATED WALL
2-HOUR RATED WALL
3-HOUR RATED WALL
4-HOUR RATED WALL
1-HOUR SMOKE BARRIER
2-HOUR SMOKE BARRIER
MAXIMUM PERMITTED TRAVEL DISTANCE
FIRE EXTINGUISHER
STANDPIPE HOSE OUTLET
EXIT FLOW AND CAPACITY0
SYMBOL KEY
NOTE 1: DETAILED OCCUPANT LOAD AND EXIT CAPACITY CALCULATIONS
ARE PROVIDED IN THE FIRE PROTECTION AND LIFE SAFETY
ANALYSIS.
NOTE 2: FURTHER DESCRIPTION REGARDING THE BUILDING
CLASSIFICATIONS, CONSTRUCTION TYPES AND FIRE
RESISTANCE RATED/SMOKE BARRIER WALLS IS INCLUDED IN
THE NARRATIVE AND THE FIRE PROTECTION AND LIFE SAFETY
ANALYSIS.
NOTE 3: NFPA 45 LAB CLASSIFICATION
2A = D
2B = D
3A = D
3B = D
4A = D
CAMPUS KEY PLAN
C
INCIDENTAL USE: CONFERENCE ROOM - OCC.
LOAD FOR ROOM CALCULATED AS 15 SF PER
OCCUPANT, LESS THAN 50 OCCUPANTS.
ALL LIFESAFETY SYMBOLS DO NOT APPEAR ON LIFESAFETY PLANS
CONSTRUCTION TYPE
ELEMENT IBC = 1B NFPA 220
STRUCT FRAME 2 HR 2
BEARING WALL 2 HR 2
2 HR 2
NON-BEARING EXT WALL TABLE 602 0
NON BEARING INT WALL 0 0
FLOOR CONST 2 2
ROOF CONSTR 1 1
TABLE 601
SEE PAGE 87 OF IBC FOR DETAIL.
Revision 12-26-18
B
STB
S.C.
1B.1
BUSINESS
P
S
B
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2
M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2
R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
(1
0'
6"
6"
0'
0'
123456
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
BLDG 08 LIFE SAFETY PLANS
ML MLJuly 16, 2012
08100342.00SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
"=1'-0"
BLDG 08 LEVEL 4 LIFE SAFETY PLAN
OCCUPANCY
CONSTRUCTION TYPE
EXIT CAPACITY
OCCUPANT LOAD
MAX.TRAVEL DIST.
PERMITTED
B
II (222)
300' - 0"
RESEARCH #08
ONE INCH = FORTY FEET (1" = 40')
0' 15' 30' 0' 40' 80'
GRAPHIC SCALE
OVERSIZED DOOR KICK PLATES
12-26-18
CORRIDORS AND STAIRS NUMBER
CHANGE
7/21/2020
File details come from the government source that posted it. Updated .