LEVEL 3.5-LIFE SAFETY.pdf

PDF 359 KB Posted

Attached to
Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB)
Solicitation number
36C25624R0010
Issued by

About this file

This document appears to be a life safety plan for a federal construction project. The plan shows the floor layout, occupancy, construction type, exit capacity, and maximum travel distance for Building 08 of a replacement medical center project in New Orleans, Louisiana. It indicates the building is fully sprinklered and classified as Business occupancy, construction type IIB, with an occupant load of 160 people. The plan includes details on smoke partitions, fire-rated walls, and fire protection equipment like extinguishers and standpipes. While this document does not directly address a federal contract opportunity, it appears to be an attachment or supporting document related to the federal project identified in the related information provided.

View the file

Other files

File Type Posted
03-HJ OUTPATIENT - LVL.7 & 8-03.HJ.7-8.pdf PDF
01-BC INPATIENT - LVL.4-01.BC.4.pdf PDF
INTERSTITIAL LEVEL 4i AREA E1-Model.pdf PDF
00-A CONCOURSE - LVL.2-00.AX-2 L.S..pdf PDF
09.Q.pdf PDF
THIRD FLOOR.pdf PDF
03-HJ OUTPATIENT - LVL.1-03.HJ.1.pdf PDF
01-BC INPATIENT - LVL.3-01.BC.3.pdf PDF
RESEARCH -LEVEL 5.5-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA D1.1-Model.pdf PDF
06.SUM.pdf PDF
09.SUM.pdf PDF
07.N.SUM.pdf PDF
07-N CEP - LVL.3 & 3.5-07.N.3-3.5.pdf PDF
FOURTH FLOOR-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA E1-Model.pdf PDF
01.BC.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2.1-Model.pdf PDF
01-BC INPATIENT - LVL.5-01.5.pdf PDF
INTERSTITIAL LEVEL 3i AREA G1-Model.pdf PDF
06.M.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2.1-Model.pdf PDF
LARGE FIFTH FLOOR.pdf PDF
LARGE SIXTH FLOOR.pdf PDF
AC.0.pdf PDF
SECOND FLOOR -LIFE SAFETY.pdf PDF
SECOND FLOOR.pdf PDF
00-A CONCOURSE - LVL.4-00.AX-4 L.S..pdf PDF
INTERSTITIAL LEVEL 4i AREA G2.1-Model.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2-Model.pdf PDF
01.SUM.pdf PDF
03-HJ OUTPATIENT - LVL.4-03.HJ.4.pdf PDF
09-Q ADMIN - LVL.2, 3, 4, 5 & 6-09.Q.2-6.pdf PDF
INTERSTITIAL LEVEL 2i AREA F1-Model.pdf PDF
FOURTH FLOOR.pdf PDF
FIRST FLOOR.pdf PDF
04-K STAFF PARKING - LVL.7-04.K.7 L.S..pdf PDF
01-BC INPATIENT - LVL.6-01.BC.6.pdf PDF
INTERSTITIAL LEVEL 3i AREA D1-Model.pdf PDF
05.L.pdf PDF
INTERSTITIAL LEVEL 3i AREA D2.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA E2-Model.pdf PDF
05.SUM.pdf PDF
LARGE FOURTH FLOOR.pdf PDF
06-M TRANSITIONAL - LVL.3 & 4-06.M.3-4 (1).pdf PDF
00-A CONCOURSE - LVL.4I-00.AX-4I L.S..pdf PDF
09-Q ADMIN -.BASEMENT.pdf PDF
06-M TRANSITIONAL - LVL.1 & 2-06.M.1-2 (1).pdf PDF
00-A CONCOURSE - LVL.3-00.AX-3 L.S..pdf PDF
Show 40 more

Latest 50 of 193 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

F

P

CM

REFER TO LEVEL 3 ON

DWG

8FA102-P FOR

CONTINUATION

TO

SECURITY

FOR

DOOR

RELEASE

DN

UP

CR

3.5P301A

3.5P302A

DN

FEC

3P306

125 S.F

3P352A

OFFICE

3P304

431 S.F

3P352

OFFICE

3P308

114 S.F

3P352B

3P310

113 S.F

3P300

127 S.F

3P302

129 S.F

OFFICE

OFFICE

3P304.1

3P304.2

ELEV.

LOBBY/CORRIDOR

3.5PC01

292 S.F

3P352C

STAIR

3.5STP1

STP-1

HEALTH STUDIES

HEALTH STUDIES

S S S S S

S S S S S

S S S

F

SMOKE PARTITION

GLASS/SPRINKLER 2-HOUR ASSEMBLY (DOUBLE LINE)

GLASS/SPRINKLER 1-HOUR ASSEMBLY (SINGLE LINE)

1-HOUR RATED WALL

2-HOUR RATED WALL

3-HOUR RATED WALL

4-HOUR RATED WALL

1-HOUR SMOKE BARRIER

2-HOUR SMOKE BARRIER

MAXIMUM PERMITTED TRAVEL DISTANCE

FIRE EXTINGUISHER

STANDPIPE HOSE OUTLET

EXIT FLOW AND CAPACITY0

SYMBOL KEY

NOTE 1: DETAILED OCCUPANT LOAD AND EXIT CAPACITY CALCULATIONS

ARE PROVIDED IN THE FIRE PROTECTION AND LIFE SAFETY

ANALYSIS.

NOTE 2: FURTHER DESCRIPTION REGARDING THE BUILDING

CLASSIFICATIONS, CONSTRUCTION TYPES AND FIRE

RESISTANCE RATED/SMOKE BARRIER WALLS IS INCLUDED IN

THE NARRATIVE AND THE FIRE PROTECTION AND LIFE SAFETY

ANALYSIS.

NOTE 3: NFPA 45 LAB CLASSIFICATION

2A = D

2B = D

3A = D

3B = D

4A = D

CAMPUS KEY PLAN

C

INCIDENTAL USE: CONFERENCE ROOM - OCC.

LOAD FOR ROOM CALCULATED AS 15 SF PER

OCCUPANT, LESS THAN 50 OCCUPANTS.

ALL LIFESAFETY SYMBOLS DO NOT APPEAR ON LIFESAFETY PLANS

CONSTRUCTION TYPE

ELEMENT IBC = 1B NFPA 220

STRUCT FRAME 2 HR 2

BEARING WALL 2 HR 2

2 HR 2

NON-BEARING EXT WALL TABLE 602 0

NON BEARING INT WALL 0 0

FLOOR CONST 2 2

ROOF CONSTR 1 1

TABLE 601

SEE PAGE 87 OF IBC FOR DETAIL.

Revision 12-26-18

B

STB

S.C.

1B.1

BUSINESS

P

S

B

Q

D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2

M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2

R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

BLDG 08 LIFE SAFETY PLANS

ML MLJuly 16, 2012

08100342.00SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

NEW ORLEANS, LOUISIANA

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_09B

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

I.S.C. GROUP, INC. / IRRIGATION

DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE

1" = 40'-0"

3.5

BLDG 08 LEVEL 3.5 LIFE SAFETY PLAN

OCCUPANCY

CONSTRUCTION TYPE

EXIT CAPACITY

OCCUPANT LOAD

MAX.TRAVEL DIST.

PERMITTED

B

II (222)

300' - 0"

RESEARCH #08

ONE INCH = FORTY FEET (1" = 40')

0' 15' 30' 0' 40' 80'

GRAPHIC SCALE

(MEZZANINE TO LEVEL 3)

OVERSIZED DOOR KICK PLATES

12-26-18

CORRIDORS AND STAIRS NUMBER

CHANGE

7/21/2020

File details come from the government source that posted it. Updated .