This document appears to be a life safety plan for a federal construction project. The plan shows the floor layout, occupancy, construction type, exit capacity, and maximum travel distance for Building 08 of a replacement medical center project in New Orleans, Louisiana. It indicates the building is fully sprinklered and classified as Business occupancy, construction type IIB, with an occupant load of 160 people. The plan includes details on smoke partitions, fire-rated walls, and fire protection equipment like extinguishers and standpipes. While this document does not directly address a federal contract opportunity, it appears to be an attachment or supporting document related to the federal project identified in the related information provided.
View the file
Other files for this federal contract opportunity
Show all 50
Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
F
P
CM
REFER TO LEVEL 3 ON
DWG
8FA102-P FOR
CONTINUATION
TO
SECURITY
FOR
DOOR
RELEASE
DN
UP
CR
3.5P301A
3.5P302A
DN
FEC
3P306
125 S.F
3P352A
OFFICE
3P304
431 S.F
3P352
OFFICE
3P308
114 S.F
3P352B
3P310
113 S.F
3P300
127 S.F
3P302
129 S.F
OFFICE
OFFICE
3P304.1
3P304.2
ELEV.
LOBBY/CORRIDOR
3.5PC01
292 S.F
3P352C
STAIR
3.5STP1
STP-1
HEALTH STUDIES
HEALTH STUDIES
S S S S S
S S S S S
S S S
F
SMOKE PARTITION
GLASS/SPRINKLER 2-HOUR ASSEMBLY (DOUBLE LINE)
GLASS/SPRINKLER 1-HOUR ASSEMBLY (SINGLE LINE)
1-HOUR RATED WALL
2-HOUR RATED WALL
3-HOUR RATED WALL
4-HOUR RATED WALL
1-HOUR SMOKE BARRIER
2-HOUR SMOKE BARRIER
MAXIMUM PERMITTED TRAVEL DISTANCE
FIRE EXTINGUISHER
STANDPIPE HOSE OUTLET
EXIT FLOW AND CAPACITY0
SYMBOL KEY
NOTE 1: DETAILED OCCUPANT LOAD AND EXIT CAPACITY CALCULATIONS
ARE PROVIDED IN THE FIRE PROTECTION AND LIFE SAFETY
ANALYSIS.
NOTE 2: FURTHER DESCRIPTION REGARDING THE BUILDING
CLASSIFICATIONS, CONSTRUCTION TYPES AND FIRE
RESISTANCE RATED/SMOKE BARRIER WALLS IS INCLUDED IN
THE NARRATIVE AND THE FIRE PROTECTION AND LIFE SAFETY
ANALYSIS.
NOTE 3: NFPA 45 LAB CLASSIFICATION
2A = D
2B = D
3A = D
3B = D
4A = D
CAMPUS KEY PLAN
C
INCIDENTAL USE: CONFERENCE ROOM - OCC.
LOAD FOR ROOM CALCULATED AS 15 SF PER
OCCUPANT, LESS THAN 50 OCCUPANTS.
ALL LIFESAFETY SYMBOLS DO NOT APPEAR ON LIFESAFETY PLANS
CONSTRUCTION TYPE
ELEMENT IBC = 1B NFPA 220
STRUCT FRAME 2 HR 2
BEARING WALL 2 HR 2
2 HR 2
NON-BEARING EXT WALL TABLE 602 0
NON BEARING INT WALL 0 0
FLOOR CONST 2 2
ROOF CONSTR 1 1
TABLE 601
SEE PAGE 87 OF IBC FOR DETAIL.
Revision 12-26-18
B
STB
S.C.
1B.1
BUSINESS
P
S
B
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2
M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2
R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
(1
0'
6"
6"
0'
0'
123456
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
BLDG 08 LIFE SAFETY PLANS
ML MLJuly 16, 2012
08100342.00SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
1" = 40'-0"
3.5
BLDG 08 LEVEL 3.5 LIFE SAFETY PLAN
OCCUPANCY
CONSTRUCTION TYPE
EXIT CAPACITY
OCCUPANT LOAD
MAX.TRAVEL DIST.
PERMITTED
B
II (222)
300' - 0"
RESEARCH #08
ONE INCH = FORTY FEET (1" = 40')
0' 15' 30' 0' 40' 80'
GRAPHIC SCALE
(MEZZANINE TO LEVEL 3)
OVERSIZED DOOR KICK PLATES
12-26-18
CORRIDORS AND STAIRS NUMBER
CHANGE
7/21/2020
File details come from the government source that posted it. Updated .