About this file

This document appears to be a partial level three through six building plan and life safety drawing for a staff parking garage (Building 04-K) at the Southeast Louisiana Veterans Health Care System. The drawing includes a legend with fire safety symbols, occupancy designations, and door opening sizes. The document does not contain information about a federal contract opportunity. It appears to be an internal facilities planning document rather than a solicitation or other contracting document.

View the file

Other files

File Type Posted
03-HJ OUTPATIENT - LVL.7 & 8-03.HJ.7-8.pdf PDF
01-BC INPATIENT - LVL.4-01.BC.4.pdf PDF
INTERSTITIAL LEVEL 4i AREA E1-Model.pdf PDF
00-A CONCOURSE - LVL.2-00.AX-2 L.S..pdf PDF
09.Q.pdf PDF
THIRD FLOOR.pdf PDF
03-HJ OUTPATIENT - LVL.1-03.HJ.1.pdf PDF
01-BC INPATIENT - LVL.3-01.BC.3.pdf PDF
RESEARCH -LEVEL 5.5-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA D1.1-Model.pdf PDF
06.SUM.pdf PDF
09.SUM.pdf PDF
07.N.SUM.pdf PDF
07-N CEP - LVL.3 & 3.5-07.N.3-3.5.pdf PDF
FOURTH FLOOR-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA E1-Model.pdf PDF
01.BC.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2.1-Model.pdf PDF
01-BC INPATIENT - LVL.5-01.5.pdf PDF
INTERSTITIAL LEVEL 3i AREA G1-Model.pdf PDF
06.M.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2.1-Model.pdf PDF
LARGE FIFTH FLOOR.pdf PDF
LARGE SIXTH FLOOR.pdf PDF
AC.0.pdf PDF
SECOND FLOOR -LIFE SAFETY.pdf PDF
SECOND FLOOR.pdf PDF
00-A CONCOURSE - LVL.4-00.AX-4 L.S..pdf PDF
INTERSTITIAL LEVEL 4i AREA G2.1-Model.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2-Model.pdf PDF
01.SUM.pdf PDF
03-HJ OUTPATIENT - LVL.4-03.HJ.4.pdf PDF
09-Q ADMIN - LVL.2, 3, 4, 5 & 6-09.Q.2-6.pdf PDF
INTERSTITIAL LEVEL 2i AREA F1-Model.pdf PDF
FOURTH FLOOR.pdf PDF
FIRST FLOOR.pdf PDF
04-K STAFF PARKING - LVL.7-04.K.7 L.S..pdf PDF
01-BC INPATIENT - LVL.6-01.BC.6.pdf PDF
LEVEL 3.5-LIFE SAFETY.pdf PDF
INTERSTITIAL LEVEL 3i AREA D1-Model.pdf PDF
05.L.pdf PDF
INTERSTITIAL LEVEL 3i AREA D2.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA E2-Model.pdf PDF
05.SUM.pdf PDF
LARGE FOURTH FLOOR.pdf PDF
06-M TRANSITIONAL - LVL.3 & 4-06.M.3-4 (1).pdf PDF
00-A CONCOURSE - LVL.4I-00.AX-4I L.S..pdf PDF
09-Q ADMIN -.BASEMENT.pdf PDF
06-M TRANSITIONAL - LVL.1 & 2-06.M.1-2 (1).pdf PDF
Show 40 more

Latest 50 of 193 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STK

STAIR NO. 3-6STK1

STAIR NO. 3-6STK2

STK

ELEC

3K102

LOBBY

3K100

STAIR

3-6STK1

STAIR

3-6STK2

2HF2HF2HF2HF2HF2HF

H

F H

F

2HF

2HF 2HF 2HF 2HF

H

F

2HF 2HF

H

F H

F H

F H

F

H

F H

F

H

F H

F

H

F H

F H

F

2HF 2HF

H

F H

F H

F

H

F H

F

2HF 2HF

H

F H

F H

F H

F

1HF1HF1HF

H

F H

F H

F H

F

2HF 2HF

T.D.=265'-1"

T.D.=294'-1"

ZONE

3-6K K

STORAGE

KS-27

KP-24 KP-25

ELEV.

KP-24

ELEV.

KP-25

ELEV.

ELEV.

ELEV. ELEV.

KP-27

Issue

DateProject:

Building/Wing.

Client Project No.

AutoCAD File Name

Title Drawn by: Checked by: Date:

Location Scale:

RAM AJA

For Review

Facility:

04-K STAFF PARKING

SLVHCS LSC EVAL - 2017Life Safety Audit 2017 06-01-1706-01-17 Southeast Louisiana Veterans Health Care System 2400 Canal Street New Orleans, LA 70119

(800) 935-8387 SLVHCS, LA

The Mihalik Group 1300 West Belmont Ave., Suite 500 Chicago, Illinois 60657

(773) 929-4276

PLAN

NORTH

REFERENCE PLAN

D

E

F

G

B1

C1

M1 M2

H

J1

J2

N1

N2

B2

C2

Q

K

L

P

A

M3

04-K STAFF PARKING-LVL. 3

BUILDING

NUMBER

BUILDING

AREA

Level Three Through Six Calculation & Life Safety Plan

Revision 5/22/19

B

STB

S.C.

1B.1

BUSINESS

OVERSIZED DOOR KICK PLATES

12-26-18

SCALE: 1/16" = 1'-0"

0'

8' 16' 32'

PARTIAL LEVEL THREE THROUGH SIX - CALCULATION AND LIFE SAFETY PLAN

BUILDING 04 - K STAFF PARKING

04.K.3-6LIFE SAFETY DRAWINGS

1/16"=1'-0"

1HF 1HF

PARTITION LEGEND

1HFS

2HF 2HF

2HFS

STP STP

3-6

LIFE SAFETY SYMBOLS LEGEND

CALCULATIONS

AutoCAD SHX Text

LEVEL OF DISCHARGE - LEVEL ONE

AutoCAD SHX Text

LEVEL OF DISCHARGE - LEVEL ONE

AutoCAD SHX Text

AED

AutoCAD SHX Text

EMER PH

AutoCAD SHX Text

EMER PH

AutoCAD SHX Text

NOT ON LEVEL 6

AutoCAD SHX Text

NOT ON LEVEL 6

AutoCAD SHX Text

NOT ON LEVEL 6

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHEET/DRAWING NO:

AutoCAD SHX Text

SHEET/PAGE:

AutoCAD SHX Text

AutoCAD SHX Text

FIRE EXTINGUISHER,

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

ILLUMINATED EXIT SIGN WITH DIRECTION

AutoCAD SHX Text

FIRE EXTINGUISHER,

AutoCAD SHX Text

FIRE VALVE,

AutoCAD SHX Text

ARROW AND EXIT WIDTH

AutoCAD SHX Text

SURFACE MOUNTED ON BRACKET

AutoCAD SHX Text

IN RECESSED CABINET

AutoCAD SHX Text

STROBE AND SIREN

AutoCAD SHX Text

IN CABINET

AutoCAD SHX Text

PULL STATION

AutoCAD SHX Text

STROBE - NO SIREN

AutoCAD SHX Text

SMOKE DETECTOR

AutoCAD SHX Text

SMOKE COMPARTMENT IDENTIFICATION

AutoCAD SHX Text

FIRE DEPT. CONTROL PANEL

AutoCAD SHX Text

STANDPIPE - FIRE

AutoCAD SHX Text

SP

AutoCAD SHX Text

AED

AutoCAD SHX Text

FCP

AutoCAD SHX Text

SPEAKER

AutoCAD SHX Text

AUTOMATIC EXTERNAL DEFIBRILLATOR

AutoCAD SHX Text

MEDICAL GAS ALARM PANEL

AutoCAD SHX Text

MEDICAL GAS ZONE VALVES

AutoCAD SHX Text

CARBON DIOXIDE SENSOR

AutoCAD SHX Text

MAP

AutoCAD SHX Text

MGSV

AutoCAD SHX Text

CO2

AutoCAD SHX Text

FLOOR NUMBER, BUILDING, COMPARTMENT NUMBER

AutoCAD SHX Text

OCCUPANCY TYPE

AutoCAD SHX Text

BUILDING IDENTIFICATION

AutoCAD SHX Text

ELEVATOR / STAIR IDENTIFICATION

AutoCAD SHX Text

T.D. (TRAVEL DISTANCE TO EXIT)

AutoCAD SHX Text

EXIT AND PATH OF EGRESS

AutoCAD SHX Text

DOOR TYPE

AutoCAD SHX Text

KICK PLATE SIZE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 32"x42"

AutoCAD SHX Text 10"x34"

AutoCAD SHX Text 32"x43"

AutoCAD SHX Text 10"x42"

AutoCAD SHX Text 32"x40"

AutoCAD SHX Text 35"x42"

AutoCAD SHX Text 35"x45"

AutoCAD SHX Text 35"x46"

AutoCAD SHX Text 10"x33"

AutoCAD SHX Text 34"x43"

AutoCAD SHX Text 34"x35"

AutoCAD SHX Text 10"x46"

AutoCAD SHX Text 34"x34"

AutoCAD SHX Text 34"x42"

AutoCAD SHX Text 10"x32"

AutoCAD SHX Text 35"x35"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 10"x34.5"

AutoCAD SHX Text 10"x36"

AutoCAD SHX Text 10"x39"

AutoCAD SHX Text 34"x42.5"

AutoCAD SHX Text 46"x34"

AutoCAD SHX Text 10"x46-1/8"

AutoCAD SHX Text 10"x37"

AutoCAD SHX Text 10"x41"

AutoCAD SHX Text 10"x35"

AutoCAD SHX Text

AutoCAD SHX Text 33"x42"

AutoCAD SHX Text

AutoCAD SHX Text 10"X40"

AutoCAD SHX Text

AutoCAD SHX Text 10"X40-1/2"

AutoCAD SHX Text

AutoCAD SHX Text 22"x35"

AutoCAD SHX Text

AutoCAD SHX Text 10"x38"

AutoCAD SHX Text

AutoCAD SHX Text 32"x34"

AutoCAD SHX Text

AutoCAD SHX Text

FIRE DOORS W/OVERSIZED PROTECTIVE PLATES

AutoCAD SHX Text

APPROVED EQUIVALENCIES

AutoCAD SHX Text

JTC LETTER DATED APRIL 21,1995 TO

AutoCAD SHX Text

DEPT. OF VETERANS AFFAIRS

AutoCAD SHX Text

SUBJECT: FIREDOORS WITH OVERSIZED

AutoCAD SHX Text

PROTECTIVE PLATES

AutoCAD SHX Text

RANDOM SELECTION AND INSPECTION OF

AutoCAD SHX Text

10%%% OF FIRE DOORS BY REMOVAL OF

AutoCAD SHX Text

PROTECTIVE PLATES TO CHECK FOR

AutoCAD SHX Text

HOLES AND DAMAGE.

AutoCAD SHX Text

AutoCAD SHX Text

DOOR TYPE

AutoCAD SHX Text

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text TWO HOUR FIRE/SMOKE BARRIER TWO HOUR FIRE BARRIER ONE HOUR FIRE/SMOKE BARRIER ONE HOUR FIRE BARRIER SMOKE TIGHT BARRIER

Sheets and Views
04.K.3-6 L.S.

File details come from the government source that posted it. Updated .