View the file

Other files

File Type Posted
01152-1AI143-B2.pdf PDF
01667-2AI142-G2.pdf PDF
01150-1AI142-C2.pdf PDF
01661-2AI142-D2.pdf PDF
01663-2AI142-E2.pdf PDF
Prism Medical Bill of Materials2.pdf PDF
01665-2AI142-F2.pdf PDF
03275-6AI141-M1A.pdf PDF
36C25623R0037 0001.pdf PDF
01144-1AI141-B2.pdf PDF
01149-1AI142-C1.pdf PDF
01662-2AI142-E1.pdf PDF
03276-6AI141-M2.pdf PDF
Ceiling Lift Technical Summary2.pdf PDF
01147-1AI142-B1.pdf PDF
01145-1AI141-C1.pdf PDF
01156-1AI144-B2.pdf PDF
01154-1AI143-C2.pdf PDF
01146-1AI141-C2.pdf PDF
03277-6AI141-M3.pdf PDF
01151-1AI143-B1.pdf PDF
01155-1AI144-B1.pdf PDF
01666-2AI142-G1.pdf PDF
01148-1AI142-B2.pdf PDF
01143-1AI141-B1.pdf PDF
01660-2AI142-D1.pdf PDF
01153-1AI143-C1.pdf PDF
P09 Ceiling Lift Technical Summary.pdf PDF
P09 C450 Owner Manual.pdf PDF
P09 Building 2 Second Floor Plan - Area E1 and E2.pdf PDF
P09 Bariatric Room Request List.pdf PDF
P09 01 45 00 Quality Control.pdf PDF
P09 01 35 26 Safety Requirements.pdf PDF
P09 01 33 23 Shop Drawings Product Data Samples.pdf PDF
P09 Building 6 Second Floor Plan Area M1.pdf PDF
P09 Building 2 Second Floor Plans - Area E1 and E2.pdf PDF
36C25623R0037.docx DOCX document
P09 Building 1 Third Floor Plan.pdf PDF
P09 00 01 00 VA Master Specs Table of Contents.pdf PDF
P09 Building 6 Third Floor Plan Area M2.pdf PDF
P09 01 00 00 General Requirements.pdf PDF
P09 Architectural Details.pdf PDF
P09 Building 6 Second Floor Plan M2.pdf PDF
P09 Building 6 First Floor Plan M1.pdf PDF
P09 Building 2 Fourth Floor Plan - Area F1 and F2.pdf PDF
P09 Building 1 Second Floor PLan.pdf PDF
P09 Building 2 Second Floor Plan - Area D1 and D2.pdf PDF
P09 Building 2 Second Floor Plan - Area F1 and F2.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S

B

A

AA.2

AA

XA

8.3

10.4

9' - 6"

SERVICE

BAY

2F227

2F222

2F229

TELECOM

2F227A

2F132

EMER

ELEC

2F227D

NORM

ELEC

2F227C

2F-C01

EC

SHD12

SHAFT

SHF10

2F143

REF:2F145 SIM

2F151

REF:2F148

2F101

2F110

REF:2F109

SECURITY

2F227B

2F131

2F130

FTG13

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 6"

FCD4a

FTG3g

FTG3g

FTG2cFTG2c

FTG2cFTG2c

FTG2cFTG2c

FTG3g

FTG3g

FCD4a

FTG3g

FTG3g

FTG3g

FTG3g

FTG3g

FTP2j

OPEN TO

BELOW

STAIR

2F153

FTG3g

FTG3gFTG3g

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FTW4a

FTW4c

9' - 0"

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FCD2c

FTW4a FTW4a FTW4a FTW4a FTW4a FTW4a FTW4a FTW4a FTW4a FTW4a

FTG13

ECC-A EWW-B 02

8.2

CCTV

FTG4b

9.7

2AI142-E1

2AI142-F1

2AI142-F1

2AI142-G1

2AI142-E2

2AI142-F2

2AI142-F2

2AI142-G2

2AI142-F1

2AI142-G1

2AI142-E1

2AI142-F1

00AI142-A3

00AI142-A4

FTR1b

FTR1b

6"

6"

6"

6"

6"

FCD2a

FCD2a

FCD2a

FCD2a

9' - 0"

ALIGN

FTP2c

FTP2c

FTP2c

FTP2c

FTP2c

FTP2c

ALIGN

10' - 6"

9' - 0"

P-4A

EQ

8"

1'

6" 4'

0"

1'

6" 1'

3"

8" EQ

P-1

B4

0AI520

2'

3" 8'

0"

8'

0" 8'

0"

8'

0" 8'

0"

2'

4"

EQ

EQ

EQ

TYP DIM

FOR FCD2c

AT 2A212

8"

332332 332332

314 314

EQ EQ

5' - 8"

314 342 342 342

A.5

ELEV

FP-05

ELEV

FS-06

SHAFT

SHF08

1'

3" 306

9.8

2F100A

E5

0AI521

SIM

E5

0AI521

SIM

E5

0AI521

SIM

E5

0AI521

SIM

AL

IG

N

6"

6"

0AI520

C6 TYP

REFER TO LS AND FP

DRAWINGS FOR

GLASS/SPRINKLER

ASSEMBLY ON BOTH

SIDES OF GLASS

2F100

1' - 9" 1' - 9"

A2

0AI527

A2

0AI527

ALIGN

MTA3c

MTA3cMTA3c

MTA3c

FTG2c

FTG2c

FTG2c

FTG2c

FTG2c

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

2AI142-F1

BLDG 2 - SECOND FLOOR - AREA F1 - RCP

JG KOFebruary 29, 2012

02629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

I.S.C. GROUP, INC. / IRRIGATION

DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE

SCALE: 1/8" = 1'-0"

SECOND FLOOR REFLECTED CEILING PLAN - AREA F11

RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH GRAPHIC DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARTITION SCHEDULE SHEET

0AS002 FOR MORE INFORMATION.

DIMENSIONS: DIMS ARE TO FINISH FACE OF WALL OR SOFFIT UON

GYPSUM BOARD BULKHEADS:

CONDITION 1: SINGLE STUD THICKNESS LESS THAN OR EQUAL TO 8'-0" IN

LENGTH SHALL BE FLUSH WITH BOTTOM OF ADJACENT ACOUSTIC TILE

CEILINGS UON. SEE OPTION BELOW ALSO.

CONDITION 2: SINGLE STUD THICKNESS GREATER THAN 8'-0" LENGTH

SHALL BE 2 IN BELOW LOWEST ADJ FINISHED CLG UON.

OPTION: IN LIEU OF CONSTRUCTED GYP BULKHEAD SHOWN AT FLUSH HT

CORR INTERSECTION, CONTINUE CLG GRID FOR ONE CORRIDOR, UTILIZING

PRE-CUT 6" WIDE TILES AT END OF RUN.

GYPSUM BOARD SOFFITS: HT AFF NOTED ON RCP. REFER TO TYP DET

D1/0AI532 FOR GYP BD SOFFITS AT CASEWORK LOCATIONS.

CEILING MATERIAL TRANSITIONS, FLUSH CONDITIONS: REFER TO STD

DETAILS B4 (SHADOW MOLD) & C4 / 0AI520 (TRANSITION TRIM SIMILAR TO

TRANSITION MOLDING #7901 OR #7902 BY ARMSTRONG) FOR NON-FLUSH

CONDITIONS: REFER TO STD DETS ON 0AI520. SEE CODED NOTES FOR USE

OF TRIM PROFILES AT MATL TRANSITIONS.

WHEN FLOOR HEIGHT VARIES IN A ROOM, THE CEILING HT SHOWN IS HT

ABOVE FLOOR AT ENTRY.

FINAL SELECTION OF CLG MTD IMAGING EQUIP HAS NOT BEEN MADE AT THIS

TIME. EQUIP SHOWN FOR BUDGETING PURPOSES ONLY. LTG & HVAC

DEVICES SHOWN FOR QTY. LOCATION OF DEVICES MAY SHIFT W/ FINAL

EQUIP SELECTION.

11 70 00 PATIENT LIFTS SHOWN DIAGRAMMATICALLY FROM ONE VENDOR AS

BASIS OF DESIGN. REFER TO RM EQUIP REPORT & SPECS FOR OTHER

VENDORS. CM TO PROVIDE UNISTRUT STRUCTURE FOR SUPPORT. REFER

TO STRUCT DET 5/0SF506. DIFFERENT VENDORS HAVE DIFFERENT

REQUIREMENTS FOR SPACING OF THEIR SUPPORTS, THEREFORE CM TO

PERFORM FINAL COORD OF ABV CLG SUPPORTS W/ SELECTED VENDOR'S

SHOP DWGS & OTHER ABV CLG TRADES.

ACOUSTIC TILE CLGS TO BE CENTERED IN BOTH DIRECTIONS IN ROOM TYP,

UON OR DIMENSIONED OTHERWISE. IF DIMENSION IS PROVIDED IN ONE

DIRECTION ONLY, ASSUME GRID IS CENTERED IN OTHER DIRECTION.

CUT TILES SHALL BE NO SMALLER THAN 4 INCHES IN ANY DIRECTION.

CLG FINISHES/ MATLS NOTED ON TYPICALS FINISH SCHEDULE.

PROVIDE SHADOW MOLD EDGE TREATMENT AT PERIMETER OF ROOM FOR

THE FOLLOWING TYP AREAS/ROOMS: ALL CORRIDORS, WAITING &

SUBWAITING AREAS, CONCOURSE, NURSE'S STATIONS, RECEPT & COMM

DESKS, PATIENT ROOMS, ENTRY VESTIBULES, ELEV LOBBIES, CANTEEN,

RETAIL, & CAFES.

PLASTIC LAMINATE (P-LAM) CLOSURE PANELS (IN LIEU OF GYP SOFFITS)

OVER CASEWORK -SEE INT ELEV SERIES DWGS.(XAI400, xAI200 SERIES).

TASK LTG UNDER WALL CABS INDICATED, SEE LEGEND. REFER TO INT ELEVS

AND/OR ENLARGED VIEWS FOR ALL WALL, CABINET, AND MILLWORK

LIGHTING NOT SHOWN ON RCPS (XAI200 AND/OR XAI400 SERIES)

NOT ALL SHEET NOTES APPLY TO SHEET.

CENTER LIGHT FIXTURE AND OTHER CEILING DEVICES W/IN ACOUSTIC TILE

UON. IF ONLY DIMENSIONED IN ONE DIRECTION, ASSUME DEVICE IS

CENTERED IN THE OTHER DIRECTION.

DIMS TO CENTERLINE OF LIGHT FIXTURE UON.

EXPOSED TO VIEW PORTIONS OF CEILING DEVICES SUPPLIED BY OTHER

TRADES TO MATCH SPECIALTY WOOD CEILING FINISHES AS CLOSE AS

PRACTICAL. REF TO SECT 09 54 27, & ACOUSTIC WD CLGS 09 54 23 LINEAR

MTL CLG ALSO. DEVICES IN MTL CLG TO MATCH MTL CLG FIN/COLOR.

EXIT SIGNAGE/LIGHTING SHOWN ON ELECTRICAL LIGHTING DRAWINGS.

REFER TO XEL100 SERIES DRAWINGS.

LIGHT FIXTURE TAGS SHOWN ON RCPs TO DISTINGUISH LIGHT FIXTURE

SYMBOL FROM HVAC GRILL SYMBOL. LIGHT FIXTURE SCHEDULE & XEL

SERIES DWGS GOVERN FOR FIXTURE SPECIFICATION. ARCHITECTURAL

RCPs GOVERN FOR LIGHT FIXTURE LOCATION.

SPRINKLER HEADS, SMOKE DETECTORS, NURSE CALL DEVICES, OTHER

MISC. ELECTRICAL DEVICES ARE SHOWN & DIMENSIONED ON

ARCHITECTURAL RCPS FOR PUBLIC AREAS TYPICALLY.

FOR ABOVE NAMED ITEMS NOT SHOWN, ORGANIZE DEVICES IN CENTER OF

TILE OF SUSPENDED CLGS & ALIGN MULTIPLE DEVICES DOWN CORRIDORS

AND THROUGHOUT LARGE ROOMS, COORD W/ OTHER TRADE'S DEVICES.

ABOVE CLG SUPPORT FOR CLG MNTD MEDICAL EQUIP: SHEET NOTES

DESCRIBE EQUIP GENERICALLY & REFERENCE APPROP SUPPORT DETAIL.

(EXAMPLES: #327 AND #343) REFER TO PROJECT MANUAL FOR LISTED EQUIP

NOTED IN SUPPORT DETAILS.

GENERAL RCP NOTES

RCP SHEET NOTES

10 22 26 FOLDING PANEL PARTITION TO SUBDIVIDE ROOMS, SEE

DOOR SCHEDULE. REF DET B4/0AI503.

12 34 00 PLASTIC LAMINATE CLOSURE PANEL ABV CASEWORK. SEE

DTL C1/0AI532.

GYP BD SHADE POCKET FOR MANUAL SINGLE ROLLER SHADE(S)

(SECTION 12 24 00) FINISHED POCKET SIZE PER DETAILS ON 0AI522

AS REFERENCED ON RCPs. SEE NOTE BELOW REGARDING SHOP

DWGS AND BREAK POINTS FOR MULTIPLE SHADES.

GYP BD SHADE POCKET FOR MANUAL DOUBLE SHADE(S) (SECTION

12 24 00). SEE DETAILS ON 0AI522 AS REFERENCED ON RCPs.

GENERALLY WINDOWS IN EXCESS OF 10FT IN LENGTH REQUIRE

MULTIPLE SHADES TO SPAN THE LENGTH OF WINDOW. PROVIDE

SHOP DRAWINGS INDICATING NUMBER OF SHADES AND BREAK

POINT (TO BE AT A VERTICAL MULLION).

08 33 26 OVERHEAD COILING GRILLES. REFER TO DOOR SCHED.

CONTINUOUS LINEAR DIFFUSER IN VERTICAL PLANE OF SOFFIT.

SEE INT ELEVS FOR HT.

ACOUSTIC TILE CUT TO DIMENSION NOTED TO ALLOW GRID

ALIGNMENTS SHOWN.

CONTINUOUS GYP BD POCKET FOR RECESSED LT FIXT. SEE DETAIL

D3/0AI520.

STAIR BELOW W/ GLASS ENCLOSURE. REFER TO 3AS700 SERIES

DWGS. SEE DETS & ELEC LIGHTING DWGS FOR ILLUM HANDRAIL.

07 95 13 EXPANSION JT COVER IN CLG - SEE DETAILS SHT 0AI517

09 53 14 CEILING TERMINATION SYSTEM (6" NOM) ARMSTRONG

"AXIOM" OR EQUAL. REF STD DETAILS 0AI520 - 0AI529. DETAILS ARE

TAGGED ON PLANS.

09 54 23 METAL CEILING

LIGHT COVE FIXTURE IN CONSTRUCTED POCKET. REF DETS D5, D6,

E6 /0AI520. SEE RCP FOR DET CALLOUTS.

CLG DEVICE (DIFFUSER, LIGHT FIXT, SPEAKER, EXHAUST GRILL,

ETC) ALIGNED WITH COLUMN CENTERLINE.

TOP OF STRUCTURAL DECKING AT 12'-3 1/2" AFF. REF DET 10/

SF501.

3XX

301.

302.

303A.

303B/ 303C.

304.

305.

306.

307.

308.

310.

311.

312.

313.

314.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

RCP SHEET NOTES - continued300

10 21 23 & 10 28 00 CURTAIN TRACK "TRK0310" OR "ST-1". REFER TO

ACTIVATION REPORT FOR CCT (TRK0310) OR TOIL ACCESSORY SCHED

FOR SC TRACK (ST-1). PROVIDE SPLIT TRACK AS REQ'D WHERE PATIENT

LIFT TRACK CROSSES SC TRACK (EX. PAT TLT RMS BLDG 1 & 6) SEE MTG

DET C3/0AI524.

10 28 00 SHOWER CURTAIN TRACK "ST-2". REFER TO TOIL ACCESSORY

SCHED SHEET 0AI202. SEE MTG DET B3/0AI524.

09 54 26 LINEAR WOOD GRILLE WITH ACOUSTIC INSULATION IN

SUSPENDED CEILING GRID.

OMIT 2X4 ACOUSTIC INSULATION BOARD ABOVE LINEAR WOOD GRILLE

FOR RETURN AIR PLENUM.

11 70 00 PATIENT LIFT TRACK - SUSPENDED BELOW FINISHED CLG.

TRACK STOPS 8 INCHES FROM PARTITION WHERE WALL MTD MOTOR

DOCKING STATION OCCURS AND 6 INCHES FROM ANY WALL CAB OR

OTHER OBSTRUCTION MTD TO WALL. SEE DET B1/0AI524.

11 70 00 PATIENT LIFT TRACK RECESSED IN CEILING. OFFSET FROM

WALL IS 6 INCHES TYPICALLY AND 8 INCHES FROM WALL IF MOTOR

DOCKING STATION IS SPECIFIED. SEE DET B2/0AI524. RERFER TO

EQUIPMENT ACTIVATION REPORT FOR SCHEDULE OF BLDG 3 ROOMS

NOTED AS ADD ALT 8.02.

11 70 00 SUSP PATIENT LIFT TRACK PATH FOR OBSERV RMS NOTED IN

ENLARGED TYP RCP. NOTE THAT SOME OBSERV RMS CONTAIN ARCH

CONSTRAINTS (EX. COL ENCLOSURES) THAT REQ'R SHIFTING LIFT

TRACK POSITION. SUBMIT FULLY DIMENSIONED SHOP DWGS FOR EA

OBSERV RM (12 TOTAL). REF DET B1/0AI524.

EXHAUST DUCT

EXHAUST HOOD

SPRINKLER HEADS ON INTERIOR SIDE OF GLASS FOR 10FT FROM

CORNER, REFER TO LIFE SAFETY DWGS AND FIRE PROTECTION DWGS.

09 81 29 SPRAYED ACOUSTICAL INSULATION: PROVIDE 1 INCH TO

UNDERSIDE OF STRUCTURE.

09 81 29 SPRAYED ACOUSTICAL INSULATION: PROVIDE 3 INCHES TO

UNDERSIDE OF STRUCTURE.

07 81 23 APPLY EPOXY PRIMER & INTUMESCENT FIREPROOFING TO

UNDERSIDE OF STRUCT. SSPC-6 SURFACE PREP REQUIRED.

SURGICAL LIGHT AND/OR COLUMN- PROVIDE ABOVE CLG SUPPORT PER

DET E2/0AI524.

WDPNL-1 APPLIED TO SOFFIT.

LINEAR DIFFUSER - REFER TO MECH DWGS

FLAT PANEL DISPLAY MOUNTED ON CLG POLE MONITOR MOUNT.

LOCATE MOUNTING PLATE CENTERED IN TILE UON. PROVIDE DATA

/ELEC ABV CLG AS REQ'D. REFER TO XTA SERIES (AV INFRA-

STRUCTURE) DRAWINGS. SEE MOUNTING DET C5/0AI524.

CEILING DEVICE AND/OR FIXTURE (LIGHT, DIFFUSER, SPRINKLER HEAD,

ETC) CENTERED WITHIN ALCOVE AND/OR SHOWER ENCLOSURE UON.

EXPOSED STRUCTURE - REFER TO FINISH SCHEDULE AND SPECS FOR

ANY APPLIED FINISH OR FIREPROOFING NOT NOTED ON RCPs.

SLOTTED CHANNEL FRAMING FOR LIGHT FIXTURE SUPPORT. FOR

MULTIPLE LIGHTS SUPPORTED BY A SINGLE CHANNEL, SPACE LIGHTS

EQUALLY. CENTER SINGLE OR MULT SUPPORTS IN ROOM OR AREA UON

OR DIMENSIONED. IF DIMENSIONED IN ONE DIRECTION ONLY, ASSUME

CENTERED IN OTHER DIRECTION. MOUNT TOP OF LIGHT AT 15'-0" A.F.F.

SLOTTED CHANNEL FRAMING - FOR LIGHT FIXTURE SUPPORT. FOR

MULTIPLE LIGHTS SUPPORTED BY A SINGLE CHANNEL, SPACE LIGHTS

EQUALLY. CENTER SINGLE OR MULT SUPPORTS IN ROOM OR AREA

UON OR DIMENSIONED. IF DIMENSIONED IN ONE DIRECTION ONLY

ASSUME CENTERED IN OTHER DIRECTION. MOUNT TOP OF LIGHT AT

17'-6" A.F.F.

HVAC CONTRACTOR TO COORD FINAL HOOD EXHAUST CONNECTION

SIZE & LOCATION W/ APPRVD SHOP DWGS. PROVIDE DUCTWORK

TRANSITION AS REQ'D FOR HOOD CONNECTION.

EMERGENCY SHOWER HEAD, CLG MOUNTED. CONTROL VALVE ON

WALL.

LIGHT FIXTURE(S) - WALL MOUNTED - REFER TO INTERIOR ELEVATIONS

FOR LOCATION AND EL SERIES DRAWINGS FOR FIXTURES.

RF AND/OR EMI SHIELDING REQUIRED ABOVE CEILING FOR ROOM.

LOCATE NURSE CALL CORRIDOR DOME LIGHTS IN CEILING CENTERED

ON DOOR ENTRY, 8 INCHES FROM WALL AT CORRIDORS WITH LIGHT

FIXTURE FTH5 NOTED. REFER TO xTM SERIES DWGS.

WALL MOUNTED LINEAR LIGHT FIXTURE AT 7'-6" TO BOT OF FIXTURE.

CENTER LENGTH OF FIXTURE ON CENTERLINE OF DOOR OPENING UON.

REFER ALSO TO TYPICAL INT ELEV E5/2AI210.

SLOPED TOP SOFFITS OVER CASEWORK NOT SHOWN ON RCP. REFER

TO INTERIOR ELEVATIONS. TASK LIGHITNG LIGHITNG SHOWN ON RCP

FOR REFERENCE - SEE RCP SYMBOLS LEGEND.

VERTICAL RETURN AIR GRILLE - REFER TO MECH DWGS.

CEILING LAYOUT - REFER TO MECHANICAL AND ELECTRICAL DWGS FOR

DUCT AND LIGHTING LAYOUT THIS AREA.

EXAM LIGHT AND/OR INJECTOR - PROVIDE ABOVE CLG SUPPORT PER

DET E1/0AI524.

LINE OF 2 HR HORIZONTAL SHAFT ASSEMBLY ABOVE FINISHED CEILING-

SEE DETAIL E1/0AI507.

315.

316.

317.

317A.

318.

319.

320.

321.

322.

323.

324.

325.

326.

327.

328.

329.

330.

331.

332.

333A.

333B.

334.

335.

336.

337.

338.

339.

340.

341.

342.

343.

344.

REFER TO 0AI400 FOR REFLECTED CEILING PLAN SYMBOLS LEGEND

MATCHLINES AND/OR MATCHLINE TAGS

REVISED THIS SHEET

15 BULL 015B - PRE-AWARD 08/30/2013

16 BULL 015B - VE 08/30/2013

INTERIOR BACK-UP WALL, OPENINGS, SOFFITS, ETC

AROUND PERIMETER OF BUILDING REVISED TO

COORDINATE W/ EWP-06 SKIN COST REDUCTIONS. NEW

AND/OR REVISED PLAN/SECTION/RCP DETAILS AS

INDICATED ON PLANS AND REFLECTED CEILING PLANS.

REFER TO SKETCHES :

SK-8-4-NJ-2AI142

SK-8-5-NJ-2AI142

RFI 04740: Delete light fixtures MTA3c

RFI 08231 Delete Soffit and Install Guardrail