01663-2AI142-E2.pdf
PDF 627 KB Posted
- Solicitation number
- 36C25623R0037
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S S
S S
S
S
S
S
S
S
S
S
G
F
E
C
B
A.5
Y20
5.3
7.6
7.5
8.1
9' - 0"
9' - 0"
9' - 0"
9' - 0"
2E146
2E181
2E178
2E186
2E187
REF:2E186 MIR
2E152B
2E147
REF:2E146 SIM
2E125
REF:2E126
RADIOLOGY
2E132
RADIOLOGY
2E130
2E126
CT
SCAN
2E129
2E128
2E109
2E107
2E170 2E167A
2E194
2D115
REF:2D112 SIM
2E188
2E190
2E166
2E145
REF:2E146
2E144
REF:2E146 SIM
2E140
REF:2E146
2E155
REF:2E157
2E156
REF:2E157
2E157
2E154
2E152C
2E1642E180
2E152E
2E175
2E149
2E193
2E150
SCR
2E137
2E169
2E152A
2E167
2E148
2E138
2E168
2E134
2E179
2E136
2E115
REF:2E117
RAD
ELEC
RM
2E105 2E159A
2E195
REF:2E194
2E104
EC
2E174
2E151
2E152D
2E153
2E116
REF:2E117
2E182
2E191
2E-C07
2E-C12
2E-C022E-C05
2E-C09
2E-C10
2E-C11
2E-C06
FTG10f
FTG10f FTG10f
FTG10f
FTG10d
FTG10d FTG10d
FTG10d
FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG10d
FTG10d
FTG10d
FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG3b FTG3bFTG3g
FTG3g
FTG3g
FTG3g
FTG3a FTG3a
FTG3g FTG3g
FTG10dFTG10d
FTG10d
FTG10dFTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG27a
FTG10f FTG10f
FTG10fFTG10f
FTG28
FTG10d
FTG10dFTG10d
FTG10d
FTG10d FTG10d
FTG10d
FTG10d
FTP2k
FTG10d FTG10d
FTG10d FTG10d FTG10d FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG10d FTG10d
FTG10d
FTG27a
FTG3l
FTG3l
FTG27a
FTG27a
FTG27a
FTG27a
FCD2a FCD2a
FTG2c
FTG13
FTG10iFTG10i FTG10iFTG10i
FTP1c
2E158
REF:2E157 SIM
2E159
2E135
2E133
2E192
2E139
2E189
REF:2E186 MIR
2E108
2E110 2E111
2E114
2E127
2E119
REF:2E117 SIM
2E120
FTG13
FTG13 FTG13 FTG13 FTG13
FTG13
FTG4b
8' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
10' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 6"
9' - 6"
9' - 0"
9' - 6"
9' - 0"
9' - 0" 9' - 0" 9' - 0"
9' - 6"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
FTG13
FTG3g FTG3g
FTG3g FTG3g
FTG4b FTG4b FTG4b FTG4b FCD2a FCD2aFCD2a
FTG3g
FCD4aFCD4a
FCD4aFCD4a
FTG3g
FCD4a
FTG3g
FCD4a
FCD4a FCD4a
FTG3g
FTG3g
FTG2cFTG2c
FTG2cFTG2c
FTG2cFTG2c
FTG10i FTG10iFTG10i FTG10i
FCD4a
FTS3d
FTS3d
FTS3d
8' - 6"
10' - 6"
10' - 6"
9' - 6"
FTP1c
FTS3d
FTG3g
FTG3g
FTG3g
FTG3g
FTG3g
FTG3g
FCD4a
FCD4a
FCD4a
FCD4a
FTG10d FTG10d
FCD2a
FCD2a
FTG3g
FTG3g
FTG3g
FTG3g
FTG3g
FTG3g
9' - 0"
9' - 0"
9' - 0"
9' - 6"
FTG3g
FTW4a
FTW4a
FTW4a
FTW4a
FTW4a
FTW4a
FTW4a
FTW4a
FTW4a
FTG2c FTG2c FTG2c FTG2c FTG2c FTG2c FTG2c
FTG2c FTG2c FTG2c FTG2c FTG2c FTG2c FTG2c
FTG2c FTG2c FTG2c FTG2c FTG2c FTG2c FTG2c
FTG2cFTG2cFTG2cFTG2cFTG2c
FCW3
FTG2c FTG2cFTG2cFTG2c FTG2cFTG2c
FCW3
FTW4a FTW4a FTW4aFTW4aFTG3g
FTG3g
FTW4a
FTW4a FTW4a
FTW4a
FTW4a
FTW4a
FTW4a
8' - 3"
FTG3g
8.3
6.1
FTW4a
FTW4a
FTG3g
FCD2a
FCD2a
FCD2b
FCD2b
FCD2b
FCD2b
FTG28
FCD2b
FTH5b
FTH5b
FTH5b
FTH5b
FTH5b
FTH5b
FTH5b
FTH5bFTH5b
FTH5b
FTH5b
FTH5b FTH5b FTH5bFTH5b FTH5b
FTH5a
FTH5a
FTH5a
FTH5b
FTP1c
FTG13
FTH5b
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
1'
4"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 6"
9' - 0"
2E165
2E106
2E124
REF:2E126
2E118
REF:2E117 SIM2E117
FTG2c
FTW4a FTW4a FTW4a
FTG2c FTG2c FTG2c
FCD2a
FCD2a
FCD2a
FTG27b
FTG27b
FTG27b
FTP1c
FTP1c
FCD2b FCD2b FCD2b
2E183
2AI421
C6
2AI421
C5
2AI422
F2
2AI422
D2
2AI422
B2
2AI421.2
C6
2AI421.2
D6
2AI422
B4
2AI422.1
C6
2AI422.2
C6
2AI422
C4
B 303
A A 303
A
ECC-B
1' - 6" 1' - 5"
1'
6" 1'
6"
1'
6"
8' - 10"
8' - 10"
8' - 10"
D
9' - 0"
9' - 0"
2AI142-E2
2AI142-F2
2AI142-D2
2AI142-E2
2AI142-E2
2AI142-F2
2AI142-E1
2AI142-F1
2AI142-D1
2AI142-E1
4'
4"
4'
4"
2AI142-D2
2AI142-E2
FCD2a
FCD2a
FCD2a
FCD2a
FCD2a
FTW4a
4' - 0" 6"
ALIGN
ALIGN
ALIGN
3' - 0"
6"
6"
6"
6"
9' - 0"
9' - 0"
8' - 6"
8' - 4"
9' - 0"
10' - 0"
7' - 0"
TYP DETAIL
THIS WALL
9' - 0"9' - 0"
342332
EQ
EQ
1' - 6" 1' - 6"
EQ
EQ
1' - 6" 1' - 6"
1' - 6"1' - 6"
EQ
EQ
9' - 0"
3'
7"
7' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"9' - 0"
9' - 0"
ENTRANCE
VESTIBULE
2E176
9' - 0"
9' - 0"
8' - 6"
8' - 6"
9' - 0"
8' - 4"
7' - 0"
7' - 2"
7' - 0" 8' - 4"
FCD2b
CORR
2E-C08
CORR
2E-C12
CORR
2D-C09
ENTRANCE
VESTIBULE
2E184
2AI421.1
C6
FCD4a FCD4a
FCD4a
1'
1' - 10"
1' - 10" EQ EQ
8' - 10"
8' - 10"
8' - 10" 8' - 10"
8' - 6"
OPEN TO ABOVE
INJ0109
INJ0109
FCD4a FCD4a
FCD4aFCD4a
3429' - 0"
8"
ALIGN
EQ
6"
1' - 6"
2'
3"
2' - 0"
1' - 2"
ALIGN
1' - 3"
EQ EQ
3' - 6"
6"
1' - 6"
TYP
TYP
3'
2'
0"
8' - 10"
9' - 0"
1' - 6"
ALIGN
FTG2cFTG2c
FTG2cFTG2c
9' - 6"
C4
0AI520
TY
P
1'
6"
EQ EQ
C4
0AI520
_______________D2
0AI520
9' - 0"8' - 10"
0AI520
C6
FTG2c
FCD2a
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
10' - 6"
10' - 6"
3'
6" 1'
EQ
4' - 0"
9' - 6"
9' - 0"
E1
0AI527
B2
0AI527
B2
0AI527
2' - 4"
ALIGN
B4
0AI527
A303
AA4
0AI527
_______________ C2
0AI527
SIM
_______________ B4
0AI527
FTS3c
FTG2c
FTP2k FTP2k
FTG2c
FTG2c
FTW4a
FTG2c
FTG10d
FTG8d
FTG8d
FTS3c FTS3dFTS3d
FTS3c
FTG2c
FTW4a
FTW4a
FTP4i
FTP4i
FTP4dFTP4d
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
FTG2c
EQ 8' - 0" EQ
1/
4"
8' - 5"
9' - 6"
8' - 5"
EQ
9' - 0"
6' - 4 1/8"
6'
3"
6' - 4 7/8"
C L
IS
O
F
V 2AI422.2
B6
2AI422.1
B6
2AI422.1
F6
28 28
10' - 0" 9' - 0"
10' - 0"
2AI422.2
E6 32
RFIs 1313, 342332
RFI 2853
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
2AI142-E2
BLDG 2 - SECOND FLOOR - AREA E2 - RCP
JG PSFebruary 29, 2012
02629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_08
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
SCALE: 1/8" = 1'-0"
SECOND FLOOR REFLECTED CEILING PLAN - AREA E2F6
RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH GRAPHIC DENOTING
HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO
PARTITION TAGS ON FLOOR PLANS AND PARTITION SCHEDULE SHEET
0AS002 FOR MORE INFORMATION.
DIMENSIONS: DIMS ARE TO FINISH FACE OF WALL OR SOFFIT UON
GYPSUM BOARD BULKHEADS:
CONDITION 1: SINGLE STUD THICKNESS LESS THAN OR EQUAL TO 8'-0" IN
LENGTH SHALL BE FLUSH WITH BOTTOM OF ADJACENT ACOUSTIC TILE
CEILINGS UON. SEE OPTION BELOW ALSO.
CONDITION 2: SINGLE STUD THICKNESS GREATER THAN 8'-0" LENGTH
SHALL BE 2 IN BELOW LOWEST ADJ FINISHED CLG UON.
OPTION: IN LIEU OF CONSTRUCTED GYP BULKHEAD SHOWN AT FLUSH HT
CORR INTERSECTION, CONTINUE CLG GRID FOR ONE CORRIDOR, UTILIZING
PRE-CUT 6" WIDE TILES AT END OF RUN.
GYPSUM BOARD SOFFITS: HT AFF NOTED ON RCP. REFER TO TYP DET
D1/0AI532 FOR GYP BD SOFFITS AT CASEWORK LOCATIONS.
CEILING MATERIAL TRANSITIONS, FLUSH CONDITIONS: REFER TO STD
DETAILS B4 (SHADOW MOLD) & C4 / 0AI520 (TRANSITION TRIM SIMILAR TO
TRANSITION MOLDING #7901 OR #7902 BY ARMSTRONG) FOR NON-FLUSH
CONDITIONS: REFER TO STD DETS ON 0AI520. SEE CODED NOTES FOR USE
OF TRIM PROFILES AT MATL TRANSITIONS.
WHEN FLOOR HEIGHT VARIES IN A ROOM, THE CEILING HT SHOWN IS HT
ABOVE FLOOR AT ENTRY.
FINAL SELECTION OF CLG MTD IMAGING EQUIP HAS NOT BEEN MADE AT THIS
TIME. EQUIP SHOWN FOR BUDGETING PURPOSES ONLY. LTG & HVAC
DEVICES SHOWN FOR QTY. LOCATION OF DEVICES MAY SHIFT W/ FINAL
EQUIP SELECTION.
11 70 00 PATIENT LIFTS SHOWN DIAGRAMMATICALLY FROM ONE VENDOR AS
BASIS OF DESIGN. REFER TO RM EQUIP REPORT & SPECS FOR OTHER
VENDORS. CM TO PROVIDE UNISTRUT STRUCTURE FOR SUPPORT. REFER
TO STRUCT DET 5/0SF506. DIFFERENT VENDORS HAVE DIFFERENT
REQUIREMENTS FOR SPACING OF THEIR SUPPORTS, THEREFORE CM TO
PERFORM FINAL COORD OF ABV CLG SUPPORTS W/ SELECTED VENDOR'S
SHOP DWGS & OTHER ABV CLG TRADES.
ACOUSTIC TILE CLGS TO BE CENTERED IN BOTH DIRECTIONS IN ROOM TYP,
UON OR DIMENSIONED OTHERWISE. IF DIMENSION IS PROVIDED IN ONE
DIRECTION ONLY, ASSUME GRID IS CENTERED IN OTHER DIRECTION.
CUT TILES SHALL BE NO SMALLER THAN 4 INCHES IN ANY DIRECTION.
CLG FINISHES/ MATLS NOTED ON TYPICALS FINISH SCHEDULE.
PROVIDE SHADOW MOLD EDGE TREATMENT AT PERIMETER OF ROOM FOR
THE FOLLOWING TYP AREAS/ROOMS: ALL CORRIDORS, WAITING &
SUBWAITING AREAS, CONCOURSE, NURSE'S STATIONS, RECEPT & COMM
DESKS, PATIENT ROOMS, ENTRY VESTIBULES, ELEV LOBBIES, CANTEEN,
RETAIL, & CAFES.
PLASTIC LAMINATE (P-LAM) CLOSURE PANELS (IN LIEU OF GYP SOFFITS)
OVER CASEWORK -SEE INT ELEV SERIES DWGS.(XAI400, xAI200 SERIES).
TASK LTG UNDER WALL CABS INDICATED, SEE LEGEND. REFER TO INT ELEVS
AND/OR ENLARGED VIEWS FOR ALL WALL, CABINET, AND MILLWORK
LIGHTING NOT SHOWN ON RCPS (XAI200 AND/OR XAI400 SERIES)
NOT ALL SHEET NOTES APPLY TO SHEET.
CENTER LIGHT FIXTURE AND OTHER CEILING DEVICES W/IN ACOUSTIC TILE
UON. IF ONLY DIMENSIONED IN ONE DIRECTION, ASSUME DEVICE IS
CENTERED IN THE OTHER DIRECTION.
DIMS TO CENTERLINE OF LIGHT FIXTURE UON.
EXPOSED TO VIEW PORTIONS OF CEILING DEVICES SUPPLIED BY OTHER
TRADES TO MATCH SPECIALTY WOOD CEILING FINISHES AS CLOSE AS
PRACTICAL. REF TO SECT 09 54 27, & ACOUSTIC WD CLGS 09 54 23 LINEAR
MTL CLG ALSO. DEVICES IN MTL CLG TO MATCH MTL CLG FIN/COLOR.
EXIT SIGNAGE/LIGHTING SHOWN ON ELECTRICAL LIGHTING DRAWINGS.
REFER TO XEL100 SERIES DRAWINGS.
LIGHT FIXTURE TAGS SHOWN ON RCPs TO DISTINGUISH LIGHT FIXTURE
SYMBOL FROM HVAC GRILL SYMBOL. LIGHT FIXTURE SCHEDULE & XEL
SERIES DWGS GOVERN FOR FIXTURE SPECIFICATION. ARCHITECTURAL
RCPs GOVERN FOR LIGHT FIXTURE LOCATION.
SPRINKLER HEADS, SMOKE DETECTORS, NURSE CALL DEVICES, OTHER
MISC. ELECTRICAL DEVICES ARE SHOWN & DIMENSIONED ON
ARCHITECTURAL RCPS FOR PUBLIC AREAS TYPICALLY.
FOR ABOVE NAMED ITEMS NOT SHOWN, ORGANIZE DEVICES IN CENTER OF
TILE OF SUSPENDED CLGS & ALIGN MULTIPLE DEVICES DOWN CORRIDORS
AND THROUGHOUT LARGE ROOMS, COORD W/ OTHER TRADE'S DEVICES.
ABOVE CLG SUPPORT FOR CLG MNTD MEDICAL EQUIP: SHEET NOTES
DESCRIBE EQUIP GENERICALLY & REFERENCE APPROP SUPPORT DETAIL.
(EXAMPLES: #327 AND #343) REFER TO PROJECT MANUAL FOR LISTED EQUIP
NOTED IN SUPPORT DETAILS.
GENERAL RCP NOTES
RCP SHEET NOTES
10 22 26 FOLDING PANEL PARTITION TO SUBDIVIDE ROOMS, SEE
DOOR SCHEDULE. REF DET B4/0AI503.
12 34 00 PLASTIC LAMINATE CLOSURE PANEL ABV CASEWORK. SEE
DTL C1/0AI532.
GYP BD SHADE POCKET FOR MANUAL SINGLE ROLLER SHADE(S)
(SECTION 12 24 00) FINISHED POCKET SIZE PER DETAILS ON 0AI522
AS REFERENCED ON RCPs. SEE NOTE BELOW REGARDING SHOP
DWGS AND BREAK POINTS FOR MULTIPLE SHADES.
GYP BD SHADE POCKET FOR MANUAL DOUBLE SHADE(S) (SECTION
12 24 00). SEE DETAILS ON 0AI522 AS REFERENCED ON RCPs.
GENERALLY WINDOWS IN EXCESS OF 10FT IN LENGTH REQUIRE
MULTIPLE SHADES TO SPAN THE LENGTH OF WINDOW. PROVIDE
SHOP DRAWINGS INDICATING NUMBER OF SHADES AND BREAK
POINT (TO BE AT A VERTICAL MULLION).
08 33 26 OVERHEAD COILING GRILLES. REFER TO DOOR SCHED.
CONTINUOUS LINEAR DIFFUSER IN VERTICAL PLANE OF SOFFIT.
SEE INT ELEVS FOR HT.
ACOUSTIC TILE CUT TO DIMENSION NOTED TO ALLOW GRID
ALIGNMENTS SHOWN.
CONTINUOUS GYP BD POCKET FOR RECESSED LT FIXT. SEE DETAIL
D3/0AI520.
STAIR BELOW W/ GLASS ENCLOSURE. REFER TO 3AS700 SERIES
DWGS. SEE DETS & ELEC LIGHTING DWGS FOR ILLUM HANDRAIL.
07 95 13 EXPANSION JT COVER IN CLG - SEE DETAILS SHT 0AI517
09 53 14 CEILING TERMINATION SYSTEM (6" NOM) ARMSTRONG
"AXIOM" OR EQUAL. REF STD DETAILS 0AI520 - 0AI529. DETAILS ARE
TAGGED ON PLANS.
09 54 23 METAL CEILING
LIGHT COVE FIXTURE IN CONSTRUCTED POCKET. REF DETS D5, D6,
E6 /0AI520. SEE RCP FOR DET CALLOUTS.
CLG DEVICE (DIFFUSER, LIGHT FIXT, SPEAKER, EXHAUST GRILL,
ETC) ALIGNED WITH COLUMN CENTERLINE.
TOP OF STRUCTURAL DECKING AT 12'-3 1/2" AFF. REF DET 10/
SF501.
3XX
301.
302.
303A.
303B/ 303C.
304.
305.
306.
307.
308.
310.
311.
312.
313.
314.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
RCP SHEET NOTES - continued300
10 21 23 & 10 28 00 CURTAIN TRACK "TRK0310" OR "ST-1". REFER TO
ACTIVATION REPORT FOR CCT (TRK0310) OR TOIL ACCESSORY SCHED
FOR SC TRACK (ST-1). PROVIDE SPLIT TRACK AS REQ'D WHERE PATIENT
LIFT TRACK CROSSES SC TRACK (EX. PAT TLT RMS BLDG 1 & 6) SEE MTG
DET C3/0AI524.
10 28 00 SHOWER CURTAIN TRACK "ST-2". REFER TO TOIL ACCESSORY
SCHED SHEET 0AI202. SEE MTG DET B3/0AI524.
09 54 26 LINEAR WOOD GRILLE WITH ACOUSTIC INSULATION IN
SUSPENDED CEILING GRID.
OMIT 2X4 ACOUSTIC INSULATION BOARD ABOVE LINEAR WOOD GRILLE
FOR RETURN AIR PLENUM.
11 70 00 PATIENT LIFT TRACK - SUSPENDED BELOW FINISHED CLG.
TRACK STOPS 8 INCHES FROM PARTITION WHERE WALL MTD MOTOR
DOCKING STATION OCCURS AND 6 INCHES FROM ANY WALL CAB OR
OTHER OBSTRUCTION MTD TO WALL. SEE DET B1/0AI524.
11 70 00 PATIENT LIFT TRACK RECESSED IN CEILING. OFFSET FROM
WALL IS 6 INCHES TYPICALLY AND 8 INCHES FROM WALL IF MOTOR
DOCKING STATION IS SPECIFIED. SEE DET B2/0AI524. RERFER TO
EQUIPMENT ACTIVATION REPORT FOR SCHEDULE OF BLDG 3 ROOMS
NOTED AS ADD ALT 8.02.
11 70 00 SUSP PATIENT LIFT TRACK PATH FOR OBSERV RMS NOTED IN
ENLARGED TYP RCP. NOTE THAT SOME OBSERV RMS CONTAIN ARCH
CONSTRAINTS (EX. COL ENCLOSURES) THAT REQ'R SHIFTING LIFT
TRACK POSITION. SUBMIT FULLY DIMENSIONED SHOP DWGS FOR EA
OBSERV RM (12 TOTAL). REF DET B1/0AI524.
EXHAUST DUCT
EXHAUST HOOD
SPRINKLER HEADS ON INTERIOR SIDE OF GLASS FOR 10FT FROM
CORNER, REFER TO LIFE SAFETY DWGS AND FIRE PROTECTION DWGS.
09 81 29 SPRAYED ACOUSTICAL INSULATION: PROVIDE 1 INCH TO
UNDERSIDE OF STRUCTURE.
09 81 29 SPRAYED ACOUSTICAL INSULATION: PROVIDE 3 INCHES TO
UNDERSIDE OF STRUCTURE.
07 81 23 APPLY EPOXY PRIMER & INTUMESCENT FIREPROOFING TO
UNDERSIDE OF STRUCT. SSPC-6 SURFACE PREP REQUIRED.
SURGICAL LIGHT AND/OR COLUMN- PROVIDE ABOVE CLG SUPPORT PER
DET E2/0AI524.
WDPNL-1 APPLIED TO SOFFIT.
LINEAR DIFFUSER - REFER TO MECH DWGS
FLAT PANEL DISPLAY MOUNTED ON CLG POLE MONITOR MOUNT.
LOCATE MOUNTING PLATE CENTERED IN TILE UON. PROVIDE DATA
/ELEC ABV CLG AS REQ'D. REFER TO XTA SERIES (AV INFRA-STRUCTURE)
DRAWINGS. SEE MOUNTING DET C5/0AI524.
CEILING DEVICE AND/OR FIXTURE (LIGHT, DIFFUSER, SPRINKLER HEAD,
ETC) CENTERED WITHIN ALCOVE AND/OR SHOWER ENCLOSURE UON.
EXPOSED STRUCTURE - REFER TO FINISH SCHEDULE AND SPECS FOR
ANY APPLIED FINISH OR FIREPROOFING NOT NOTED ON RCPs.
SLOTTED CHANNEL FRAMING FOR LIGHT FIXTURE SUPPORT. FOR
MULTIPLE LIGHTS SUPPORTED BY A SINGLE CHANNEL, SPACE LIGHTS
EQUALLY. CENTER SINGLE OR MULT SUPPORTS IN ROOM OR AREA UON
OR DIMENSIONED. IF DIMENSIONED IN ONE DIRECTION ONLY, ASSUME
CENTERED IN OTHER DIRECTION. MOUNT TOP OF LIGHT AT 15'-0" A.F.F.
SLOTTED CHANNEL FRAMING - FOR LIGHT FIXTURE SUPPORT. FOR
MULTIPLE LIGHTS SUPPORTED BY A SINGLE CHANNEL, SPACE LIGHTS
EQUALLY. CENTER SINGLE OR MULT SUPPORTS IN ROOM OR AREA UON
OR DIMENSIONED. IF DIMENSIONED IN ONE DIRECTION ONLY ASSUME
CENTERED IN OTHER DIRECTION. MOUNT TOP OF LIGHT AT 17'-6" A.F.F.
HVAC CONTRACTOR TO COORD FINAL HOOD EXHAUST CONNECTION
SIZE & LOCATION W/ APPRVD SHOP DWGS. PROVIDE DUCTWORK
TRANSITION AS REQ'D FOR HOOD CONNECTION.
EMERGENCY SHOWER HEAD, CLG MOUNTED. CONTROL VALVE ON WALL.
LIGHT FIXTURE(S) - WALL MOUNTED - REFER TO INTERIOR ELEVATIONS
FOR LOCATION AND EL SERIES DRAWINGS FOR FIXTURES.
RF AND/OR EMI SHIELDING REQUIRED ABOVE CEILING FOR ROOM.
LOCATE NURSE CALL CORRIDOR DOME LIGHTS IN CEILING CENTERED
ON DOOR ENTRY, 8 INCHES FROM WALL AT CORRIDORS WITH LIGHT
FIXTURE FTH5 NOTED. REFER TO xTM SERIES DWGS.
WALL MOUNTED LINEAR LIGHT FIXTURE AT 7'-6" TO BOT OF FIXTURE.
CENTER LENGTH OF FIXTURE ON CENTERLINE OF DOOR OPENING UON.
REFER ALSO TO TYPICAL INT ELEV E5/2AI210.
SLOPED TOP SOFFITS OVER CASEWORK NOT SHOWN ON RCP. REFER
TO INTERIOR ELEVATIONS. TASK LIGHTING SHOWN ON RCP FOR
REFERENCE - SEE RCP SYMBOLS LEGEND.
VERTICAL RETURN AIR GRILLE - REFER TO MECH DWGS.
CEILING LAYOUT - REFER TO MECHANICAL AND ELECTRICAL DWGS FOR
DUCT AND LIGHTING LAYOUT THIS AREA.
EXAM LIGHT AND/OR INJECTOR - PROVIDE ABOVE CLG SUPPORT PER
DET E1/0AI524.
LINE OF 2 HR HORIZONTAL SHAFT ASSEMBLY ABOVE FINISHED CEILING-
SEE DETAIL E1/0AI507.
315.
316.
317.
317A.
318.
319.
320.
321.
322.
323.
324.
325.
326.
327.
328.
329.
330.
331.
332.
333A.
333B.
334.
335.
336.
337.
338.
339.
340.
341.
342.
343.
344.
REFER TO 0AI400 FOR REFLECTED CEILING PLAN SYMBOLS LEGEND
15 BULL 015B - PRE-AWARD 08/30/2013
16 BULL 015B - VE 08/30/2013
28 BULL 029A - IMAGING 06/26/2014
32 BULL 029D - IMAGING 10/16/2014
INTERIOR BACK-UP WALL, OPENINGS, SOFFITS, ETC
AROUND PERIMETER OF BUILDING REVISED TO
COORDINATE W/ EWP-06 SKIN COST REDUCTIONS. NEW
AND/OR REVISED PLAN/SECTION/RCP DETAILS AS
INDICATED ON PLANS AND REFLECTED CEILING PLANS.
RFI 06838:
Move TV mount west of lights;
move grill south
RFI:01313 - Relocate Soffit Above Wall Cabinet
REFER TO SKETCHES :
SK-8-4-NJ-2AI142
SK-8-5-NJ-2AI142
RFI:02036 - Shift Diffuser Layout to Avoid Structural Steel Above
RFI:01990 - Clarification of Diffuser Locations
8'-0"
SEE RFI 02853:
Relocates CRAC unit from 2E137 to 2E138.
Lowers ceiling in 2E138 to 8'-0" AFF.
SEE RFI 02853:
Removes ceiling in RM 2E109 to accomodate CRAC Unit
9'-0" per Bulletin 29D
9'-0" per Bulletin 29D
9'-0" per Bulletin 29D
RFI 06712: Rotate the FTG2c fixtures to run North South as shown in Bulletin 15B
RFI 06819: Changed ceiling height to 10'0"
File details come from the government source that posted it. Updated .