View the file

Other files

File Type Posted
01152-1AI143-B2.pdf PDF
01667-2AI142-G2.pdf PDF
01150-1AI142-C2.pdf PDF
01661-2AI142-D2.pdf PDF
01663-2AI142-E2.pdf PDF
Prism Medical Bill of Materials2.pdf PDF
01665-2AI142-F2.pdf PDF
03275-6AI141-M1A.pdf PDF
36C25623R0037 0001.pdf PDF
01144-1AI141-B2.pdf PDF
01149-1AI142-C1.pdf PDF
01662-2AI142-E1.pdf PDF
03276-6AI141-M2.pdf PDF
Ceiling Lift Technical Summary2.pdf PDF
01147-1AI142-B1.pdf PDF
01145-1AI141-C1.pdf PDF
01156-1AI144-B2.pdf PDF
01154-1AI143-C2.pdf PDF
01146-1AI141-C2.pdf PDF
03277-6AI141-M3.pdf PDF
01664-2AI142-F1.pdf PDF
01151-1AI143-B1.pdf PDF
01155-1AI144-B1.pdf PDF
01666-2AI142-G1.pdf PDF
01148-1AI142-B2.pdf PDF
01660-2AI142-D1.pdf PDF
01153-1AI143-C1.pdf PDF
P09 Ceiling Lift Technical Summary.pdf PDF
P09 C450 Owner Manual.pdf PDF
P09 Building 2 Second Floor Plan - Area E1 and E2.pdf PDF
P09 Bariatric Room Request List.pdf PDF
P09 01 45 00 Quality Control.pdf PDF
P09 01 35 26 Safety Requirements.pdf PDF
P09 01 33 23 Shop Drawings Product Data Samples.pdf PDF
P09 Building 6 Second Floor Plan Area M1.pdf PDF
P09 Building 2 Second Floor Plans - Area E1 and E2.pdf PDF
36C25623R0037.docx DOCX document
P09 Building 1 Third Floor Plan.pdf PDF
P09 00 01 00 VA Master Specs Table of Contents.pdf PDF
P09 Building 6 Third Floor Plan Area M2.pdf PDF
P09 01 00 00 General Requirements.pdf PDF
P09 Architectural Details.pdf PDF
P09 Building 6 Second Floor Plan M2.pdf PDF
P09 Building 6 First Floor Plan M1.pdf PDF
P09 Building 2 Fourth Floor Plan - Area F1 and F2.pdf PDF
P09 Building 1 Second Floor PLan.pdf PDF
P09 Building 2 Second Floor Plan - Area D1 and D2.pdf PDF
P09 Building 2 Second Floor Plan - Area F1 and F2.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S

S S

S S

S

S

B

XE

A

XC

4.2

G

1B208

1B1411B139 1B1511B140

1B193A

1B192A

1B192B

1B150

1B192C

1B191D

1B143 1B144

1B201

1B195A 1B193D

1B193B

1B195B1B195D 1B195C

1B192F

1B192D1B192E

1B193C1B200

1B137 1B138

1B134

1B130

1B132

SERVICE

BAY

1B123

TELECOM

1B123D

EMER

ELEC

1B123A

NORM

ELEC

1B123B

1B135

1B204

1B120

1B100

1B194

1B203

1B142

STAIR

STB-1

1B-C01

1B-C03

1B-C08

1B-C05

1B-C09

1B-C10

1B-C11

1B-C12

1B121

1 A I1

-B

1 A

I1

-B

AI

1-

A 1 1 A

I1

-B

1AI141-B1

1AI141-C1

9' - 6"

9' - 6" 9' - 6" 9' - 6" 9' - 6" 9' - 6" 9' - 6" 9' - 6" 9' - 6" 9' - 6"

9' - 6"

9' - 6"

9' - 6"

9' - 6"

9' - 0"

9' - 0"

9' - 6"

10' - 0"

9' - 6"

9' - 6"

1B206

FTP2lFTP1cFTP2lFTP2lFTP2lFTP2lFTP2lFTP2lFTP2lFTP2l

FTP1c

FTP1c

FTP1c

FTP1c

FCD2aFCD2a

FTP1c FTP1c

FTG3g

FTP1c

FTP1c FTP1c FTP1c FTP1c FTP1c FTP1c

9' - 0"

2.5

A.4

6.3

SECURITY

1B123C

5.1

Y10

ELEV

BP-5

ELEV

BP-6

ELEV

BP-7

ELEV

BS-1

ELEV

BS-4

1B192H

G.6

9' - 0"

9' - 0"

9' - 0"

9' - 6"

1B106 1B-C02

1B1081B110

1B114

1B102 1B105

1B107 1B109

FTG2c FTG2c FTG2c FCD2a FCD2a FCD2a

10' - 0"

FCD2a

FTP1eFTP1e FTP1e

FTW4a FTW4a

FTW4a FTW4a

FTW4a FTW4a

FTW4a FTW4a

FTG2c

FTG2c

FTG2c

FTG2c

FTG2c

FTP1cFTP1cFTP1c

FTW4a FTW4a FTW4a FTW4a FTW4a FTW4a

MTT1 MTT1 MTT1 MTT1 MTT1 MTT1

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FTW4a

FCD2a

FTW4a

FTW4a

FTW4a

FTW4a FTW4a FTW4a

FTP1kFTP1kFTP1k

FTP1k FTP1k FTP1k

F

D

C

9' - 6"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 6"

1B152

1AI402

D5

FTG13 FTG13

9' - 0"

FTW4a

FTW4a FTW4a

FTW4a FTW4a

FTW4a

FTP1c FTP1c

1B116

1B112

1B111

1.3

8' - 6"

3'

- 2

10' - 0"

1B103 9' - 0"

9' - 6"

1B-C02A

9' - 6"

FTP1c FTP1c FTP1c

FTP1k FTP1k FTP1k

FTG13

ECC-A

ECC-A

ECC-A

ECC-A

EWW-B

10' - 6"

10' - 6"

FTG3g

9' - 0"

E.6

4' - 2" 8" 1' - 2"

FCD2a

FCD2a

FCD2aFCD2a

FCD2a

FCD2a

1'

- 7

3' - 8"

3'

- 1

1"

6' - 0" 6' - 0" 2' - 10" 6"3' - 1"

MTT1 MTT1 MTT1

XD

B3

0AI502

D3

0AI520

B3

0AI520

B4

0AI520

1AI141-B1

1AI141-C1

FCW3 FCW3 FCW3

FTP1k

FTP1k

FTG3g

FTG3g

FTG3g

1B191C

2' - 3" 8' - 0"

4'

- 1

2' - 0"

9' - 6"

9' - 6" 1'

- 9

6"

ALIGN

6"

ALIGN

1' - 2"

ALIGN

1'

- 4

6"

6"

6"

1' - 9"

EQ EQ

10"

6"

6"

1'

- 0

6"

3'

- 3

2'

- 0

1'

- 0

10"

1'

- 2

"7"

2'

- 2

9' - 6"

10' - 0"

9' - 0"

10' - 0"

9' - 6"9' - 6"

9' - 6"

REFER TO 1AS401 FOR

CHAPEL DRAWING

E1

0AI522

E1

0AI522

TYP DETAIL

THIS WALL

TYP DETAIL

THIS WALL

TYP DETAIL

THIS WALL

TYP DETAIL

THIS WALL

D1

0AI521

7' - 6"

1AI141-B2

1AI141-C2

E1

0AI507

E1

0AI507

3' - 0" 3' - 0" 14' - 0" 3' - 0" 3' - 0" 11' - 10" 2' - 2" 3' - 0" 3' - 0"

1B-C04 8' - 10"

10' - 0"

9' - 4"

A1

0AI521

A1

0AI521

B4

0AI520

D3

0AI520

9' - 0"

2'

- 8

6"

2'

- 0

A2

0AI512

5'

- 6

5'

- 6

10"

B.6

7' - 2"

ELEV

BS-3

FUTURE

ELEV

BS-2

SLOPE

4.8

1' - 6" 1' - 6"

1'

- 6

9' - 6"

MTT1 FIX: ALTERNATE 8.32

ADDITIONAL LIGHTING

1' - 8"

FCD2a FCD2a

FCD2aFCD2aFCW3

FCW3

FCW3

FCW3

FCD2aFCD2a

6"

10' - 0"

10' - 0"

10' - 0"

FCD2a

FCD2a

FCD2a

FCD2aFCD2a FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a

FCD2a FCD2a

4.9

B4

0AI520

B4

0AI520

A2

0AI512

6"FCD2a FCD2a

9' - 6"

A 10' - 10" 9' - 6"303

A10' - 10" 9' - 6"303 A10' - 10" 9' - 6"9' - 6"

6"

A10' - 10" 9' - 6"303

A10' - 10" 9' - 6"303 A 10' - 10"9' - 6"303

A

10' - 10"

9' - 6"9' - 0" 10' - 10"9' - 10"

A9' - 0"

9' - 10"

A303

A A

9' - 6" 10' - 6"

A

A

A

A

A

A

A

9' - 6"

10' - 10" 9' - 6"

10' - 10"

C1

0AI522

C1

0AI522

C1

0AI522

10' - 10"

10' - 0"

D1

0AI521

7' - 3"

A1

0AI522

A

SHB05

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

1AI141-B1

BLDG 1 FIRST FLOOR REFLECTED CELING

PLAN - AREA B1

JG KOFebruary 29, 2012

01629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

I.S.C. GROUP, INC. / IRRIGATION

DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE

SCALE: 1/8" = 1'-0"

BLDG 1 FIRST FLOOR REFLECTED CEILING PLAN - AREA B11

RATED WALLS: ARE INDICATED IN PLAN AND RCP WITH GRAPHIC DENOTING

HOURLY RATING AND/OR RESISTANT TO PASSAGE OF SMOKE. REFER TO

PARTITION TAGS ON FLOOR PLANS AND PARTITION SCHEDULE SHEET

0AS002 FOR MORE INFORMATION.

DIMENSIONS: DIMS ARE TO FINISH FACE OF WALL OR SOFFIT UON

GYPSUM BOARD BULKHEADS:

CONDITION 1: SINGLE STUD THICKNESS LESS THAN OR EQUAL TO 8'-0" IN

LENGTH SHALL BE FLUSH WITH BOTTOM OF ADJACENT ACOUSTIC TILE

CEILINGS UON. SEE OPTION BELOW ALSO.

CONDITION 2: SINGLE STUD THICKNESS GREATER THAN 8'-0" LENGTH

SHALL BE 2 IN BELOW LOWEST ADJ FINISHED CLG UON.

OPTION: IN LIEU OF CONSTRUCTED GYP BULKHEAD SHOWN AT FLUSH HT

CORR INTERSECTION, CONTINUE CLG GRID FOR ONE CORRIDOR, UTILIZING

PRE-CUT 6" WIDE TILES AT END OF RUN.

GYPSUM BOARD SOFFITS: HT AFF NOTED ON RCP. REFER TO TYP DET

D1/0AI532 FOR GYP BD SOFFITS AT CASEWORK LOCATIONS.

CEILING MATERIAL TRANSITIONS, FLUSH CONDITIONS: REFER TO STD

DETAILS B4 (SHADOW MOLD) & C4 / 0AI520 (TRANSITION TRIM SIMILAR TO

TRANSITION MOLDING #7901 OR #7902 BY ARMSTRONG) FOR NON-FLUSH

CONDITIONS: REFER TO STD DETS ON 0AI520. SEE CODED NOTES FOR USE

OF TRIM PROFILES AT MATL TRANSITIONS.

WHEN FLOOR HEIGHT VARIES IN A ROOM, THE CEILING HT SHOWN IS HT

ABOVE FLOOR AT ENTRY.

FINAL SELECTION OF CLG MTD IMAGING EQUIP HAS NOT BEEN MADE AT THIS

TIME. EQUIP SHOWN FOR BUDGETING PURPOSES ONLY. LTG & HVAC

DEVICES SHOWN FOR QTY. LOCATION OF DEVICES MAY SHIFT W/ FINAL

EQUIP SELECTION.

11 70 00 PATIENT LIFTS SHOWN DIAGRAMMATICALLY FROM ONE VENDOR AS

BASIS OF DESIGN. REFER TO RM EQUIP REPORT & SPECS FOR OTHER

VENDORS. CM TO PROVIDE UNISTRUT STRUCTURE FOR SUPPORT. REFER

TO STRUCT DET 5/0SF506. DIFFERENT VENDORS HAVE DIFFERENT

REQUIREMENTS FOR SPACING OF THEIR SUPPORTS, THEREFORE CM TO

PERFORM FINAL COORD OF ABV CLG SUPPORTS W/ SELECTED VENDOR'S

SHOP DWGS & OTHER ABV CLG TRADES.

ACOUSTIC TILE CLGS TO BE CENTERED IN BOTH DIRECTIONS IN ROOM TYP,

UON OR DIMENSIONED OTHERWISE. IF DIMENSION IS PROVIDED IN ONE

DIRECTION ONLY, ASSUME GRID IS CENTERED IN OTHER DIRECTION.

CUT TILES SHALL BE NO SMALLER THAN 4 INCHES IN ANY DIRECTION.

CLG FINISHES/ MATLS NOTED ON TYPICALS FINISH SCHEDULE.

PROVIDE SHADOW MOLD EDGE TREATMENT AT PERIMETER OF ROOM FOR

THE FOLLOWING TYP AREAS/ROOMS: ALL CORRIDORS, WAITING &

SUBWAITING AREAS, CONCOURSE, NURSE'S STATIONS, RECEPT & COMM

DESKS, PATIENT ROOMS, ENTRY VESTIBULES, ELEV LOBBIES, CANTEEN,

RETAIL, & CAFES.

PLASTIC LAMINATE (P-LAM) CLOSURE PANELS (IN LIEU OF GYP SOFFITS)

OVER CASEWORK -SEE INT ELEV SERIES DWGS.(XAI400, xAI200 SERIES).

TASK LTG UNDER WALL CABS INDICATED, SEE LEGEND. REFER TO INT ELEVS

AND/OR ENLARGED VIEWS FOR ALL WALL, CABINET, AND MILLWORK

LIGHTING NOT SHOWN ON RCPS (XAI200 AND/OR XAI400 SERIES)

NOT ALL SHEET NOTES APPLY TO SHEET.

CENTER LIGHT FIXTURE AND OTHER CEILING DEVICES W/IN ACOUSTIC TILE

UON. IF ONLY DIMENSIONED IN ONE DIRECTION, ASSUME DEVICE IS

CENTERED IN THE OTHER DIRECTION.

DIMS TO CENTERLINE OF LIGHT FIXTURE UON.

EXPOSED TO VIEW PORTIONS OF CEILING DEVICES SUPPLIED BY OTHER

TRADES TO MATCH SPECIALTY WOOD CEILING FINISHES AS CLOSE AS

PRACTICAL. REF TO SECT 09 54 27, & ACOUSTIC WD CLGS 09 54 23 LINEAR

MTL CLG ALSO. DEVICES IN MTL CLG TO MATCH MTL CLG FIN/COLOR.

EXIT SIGNAGE/LIGHTING SHOWN ON ELECTRICAL LIGHTING DRAWINGS.

REFER TO XEL100 SERIES DRAWINGS.

LIGHT FIXTURE TAGS SHOWN ON RCPs TO DISTINGUISH LIGHT FIXTURE

SYMBOL FROM HVAC GRILL SYMBOL. LIGHT FIXTURE SCHEDULE & XEL

SERIES DWGS GOVERN FOR FIXTURE SPECIFICATION. ARCHITECTURAL

RCPs GOVERN FOR LIGHT FIXTURE LOCATION.

SPRINKLER HEADS, SMOKE DETECTORS, NURSE CALL DEVICES, OTHER

MISC. ELECTRICAL DEVICES ARE SHOWN & DIMENSIONED ON

ARCHITECTURAL RCPS FOR PUBLIC AREAS TYPICALLY.

FOR ABOVE NAMED ITEMS NOT SHOWN, ORGANIZE DEVICES IN CENTER OF

TILE OF SUSPENDED CLGS & ALIGN MULTIPLE DEVICES DOWN CORRIDORS

AND THROUGHOUT LARGE ROOMS, COORD W/ OTHER TRADE'S DEVICES.

ABOVE CLG SUPPORT FOR CLG MNTD MEDICAL EQUIP: SHEET NOTES

DESCRIBE EQUIP GENERICALLY & REFERENCE APPROP SUPPORT DETAIL.

(EXAMPLES: #327 AND #343) REFER TO PROJECT MANUAL FOR LISTED EQUIP

NOTED IN SUPPORT DETAILS.

GENERAL RCP NOTES

RCP SHEET NOTES

10 22 26 FOLDING PANEL PARTITION TO SUBDIVIDE ROOMS, SEE

DOOR SCHEDULE. REF DET B4/0AI503.

12 34 00 PLASTIC LAMINATE CLOSURE PANEL ABV CASEWORK. SEE

DTL C1/0AI532.

GYP BD SHADE POCKET FOR MANUAL SINGLE ROLLER SHADE(S)

(SECTION 12 24 00) FINISHED POCKET SIZE PER DETAILS ON 0AI522

AS REFERENCED ON RCPs. SEE NOTE BELOW REGARDING SHOP

DWGS AND BREAK POINTS FOR MULTIPLE SHADES.

GYP BD SHADE POCKET FOR MANUAL DOUBLE SHADE(S) (SECTION

12 24 00). SEE DETAILS ON 0AI522 AS REFERENCED ON RCPs.

GENERALLY WINDOWS IN EXCESS OF 10FT IN LENGTH REQUIRE

MULTIPLE SHADES TO SPAN THE LENGTH OF WINDOW. PROVIDE

SHOP DRAWINGS INDICATING NUMBER OF SHADES AND BREAK

POINT (TO BE AT A VERTICAL MULLION).

08 33 26 OVERHEAD COILING GRILLES. REFER TO DOOR SCHED.

CONTINUOUS LINEAR DIFFUSER IN VERTICAL PLANE OF SOFFIT.

SEE INT ELEVS FOR HT.

ACOUSTIC TILE CUT TO DIMENSION NOTED TO ALLOW GRID

ALIGNMENTS SHOWN.

CONTINUOUS GYP BD POCKET FOR RECESSED LT FIXT. SEE DETAIL

D3/0AI520.

STAIR BELOW W/ GLASS ENCLOSURE. REFER TO 3AS700 SERIES

DWGS. SEE DETS & ELEC LIGHTING DWGS FOR ILLUM HANDRAIL.

07 95 13 EXPANSION JT COVER IN CLG - SEE DETAILS SHT 0AI517

09 53 14 CEILING TERMINATION SYSTEM (6" NOM) ARMSTRONG

"AXIOM" OR EQUAL. REF STD DETAILS 0AI520 - 0AI529. DETAILS ARE

TAGGED ON PLANS.

09 54 23 METAL CEILING

LIGHT COVE FIXTURE IN CONSTRUCTED POCKET. REF DETS D5, D6,

E6 /0AI520. SEE RCP FOR DET CALLOUTS.

CLG DEVICE (DIFFUSER, LIGHT FIXT, SPEAKER, EXHAUST GRILL,

ETC) ALIGNED WITH COLUMN CENTERLINE.

TOP OF STRUCTURAL DECKING AT 12'-3 1/2" AFF. REF DET 10/

SF501.

3XX

301.

302.

303A.

303B/ 303C.

304.

305.

306.

307.

308.

310.

311.

312.

313.

314.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

RCP SHEET NOTES - continued300

10 21 23 & 10 28 00 CURTAIN TRACK "TRK0310" OR "ST-1". REFER TO

ACTIVATION REPORT FOR CCT (TRK0310) OR TOIL ACCESSORY SCHED

FOR SC TRACK (ST-1). PROVIDE SPLIT TRACK AS REQ'D WHERE PATIENT

LIFT TRACK CROSSES SC TRACK (EX. PAT TLT RMS BLDG 1 & 6) SEE MTG

DET C3/0AI524.

10 28 00 SHOWER CURTAIN TRACK "ST-2". REFER TO TOIL ACCESSORY

SCHED SHEET 0AI202. SEE MTG DET B3/0AI524.

09 54 26 LINEAR WOOD GRILLE WITH ACOUSTIC INSULATION IN

SUSPENDED CEILING GRID.

OMIT 2X4 ACOUSTIC INSULATION BOARD ABOVE LINEAR WOOD GRILLE

FOR RETURN AIR PLENUM.

11 70 00 PATIENT LIFT TRACK - SUSPENDED BELOW FINISHED CLG.

TRACK STOPS 8 INCHES FROM PARTITION WHERE WALL MTD MOTOR

DOCKING STATION OCCURS AND 6 INCHES FROM ANY WALL CAB OR

OTHER OBSTRUCTION MTD TO WALL. SEE DET B1/0AI524.

11 70 00 PATIENT LIFT TRACK RECESSED IN CEILING. OFFSET FROM

WALL IS 6 INCHES TYPICALLY AND 8 INCHES FROM WALL IF MOTOR

DOCKING STATION IS SPECIFIED. SEE DET B2/0AI524. RERFER TO

EQUIPMENT ACTIVATION REPORT FOR SCHEDULE OF BLDG 3 ROOMS

NOTED AS ADD ALT 8.02.

11 70 00 SUSP PATIENT LIFT TRACK PATH FOR OBSERV RMS NOTED IN

ENLARGED TYP RCP. NOTE THAT SOME OBSERV RMS CONTAIN ARCH

CONSTRAINTS (EX. COL ENCLOSURES) THAT REQ'R SHIFTING LIFT

TRACK POSITION. SUBMIT FULLY DIMENSIONED SHOP DWGS FOR EA

OBSERV RM (12 TOTAL). REF DET B1/0AI524.

EXHAUST DUCT

EXHAUST HOOD

SPRINKLER HEADS ON INTERIOR SIDE OF GLASS FOR 10FT FROM

CORNER, REFER TO LIFE SAFETY DWGS AND FIRE PROTECTION DWGS.

09 81 29 SPRAYED ACOUSTICAL INSULATION: PROVIDE 1 INCH TO

UNDERSIDE OF STRUCTURE.

09 81 29 SPRAYED ACOUSTICAL INSULATION: PROVIDE 3 INCHES TO

UNDERSIDE OF STRUCTURE.

07 81 23 APPLY EPOXY PRIMER & INTUMESCENT FIREPROOFING TO

UNDERSIDE OF STRUCT. SSPC-6 SURFACE PREP REQUIRED.

SURGICAL LIGHT AND/OR COLUMN- PROVIDE ABOVE CLG SUPPORT PER

DET E2/0AI524.

WDPNL-1 APPLIED TO SOFFIT.

LINEAR DIFFUSER - REFER TO MECH DWGS

FLAT PANEL DISPLAY MOUNTED ON CLG POLE MONITOR MOUNT.

LOCATE MOUNTING PLATE CENTERED IN TILE UON. PROVIDE DATA

/ELEC ABV CLG AS REQ'D. REFER TO XTA SERIES (AV INFRA-STRUCTURE)

DRAWINGS. SEE MOUNTING DET C5/0AI524.

CEILING DEVICE AND/OR FIXTURE (LIGHT, DIFFUSER, SPRINKLER HEAD,

ETC) CENTERED WITHIN ALCOVE AND/OR SHOWER ENCLOSURE UON.

EXPOSED STRUCTURE - REFER TO FINISH SCHEDULE AND SPECS FOR

ANY APPLIED FINISH OR FIREPROOFING NOT NOTED ON RCPs.

SLOTTED CHANNEL FRAMING FOR LIGHT FIXTURE SUPPORT. FOR

MULTIPLE LIGHTS SUPPORTED BY A SINGLE CHANNEL, SPACE LIGHTS

EQUALLY. CENTER SINGLE OR MULT SUPPORTS IN ROOM OR AREA UON

OR DIMENSIONED. IF DIMENSIONED IN ONE DIRECTION ONLY, ASSUME

CENTERED IN OTHER DIRECTION. MOUNT TOP OF LIGHT AT 15'-0" A.F.F.

SLOTTED CHANNEL FRAMING - FOR LIGHT FIXTURE SUPPORT. FOR

MULTIPLE LIGHTS SUPPORTED BY A SINGLE CHANNEL, SPACE LIGHTS

EQUALLY. CENTER SINGLE OR MULT SUPPORTS IN ROOM OR AREA UON

OR DIMENSIONED. IF DIMENSIONED IN ONE DIRECTION ONLY ASSUME

CENTERED IN OTHER DIRECTION. MOUNT TOP OF LIGHT AT 17'-6" A.F.F.

HVAC CONTRACTOR TO COORD FINAL HOOD EXHAUST CONNECTION

SIZE & LOCATION W/ APPRVD SHOP DWGS. PROVIDE DUCTWORK

TRANSITION AS REQ'D FOR HOOD CONNECTION.

EMERGENCY SHOWER HEAD, CLG MOUNTED. CONTROL VALVE ON WALL.

LIGHT FIXTURE(S) - WALL MOUNTED - REFER TO INTERIOR ELEVATIONS

FOR LOCATION AND EL SERIES DRAWINGS FOR FIXTURES.

RF AND/OR EMI SHIELDING REQUIRED ABOVE CEILING FOR ROOM.

LOCATE NURSE CALL CORRIDOR DOME LIGHTS IN CEILING CENTERED

ON DOOR ENTRY, 8 INCHES FROM WALL AT CORRIDORS WITH LIGHT

FIXTURE FTH5 NOTED. REFER TO xTM SERIES DWGS.

WALL MOUNTED LINEAR LIGHT FIXTURE AT 7'-6" TO BOT OF FIXTURE.

CENTER LENGTH OF FIXTURE ON CENTERLINE OF DOOR OPENING UON.

REFER ALSO TO TYPICAL INT ELEV E5/2AI210.

SLOPED TOP SOFFITS OVER CASEWORK NOT SHOWN ON RCP. REFER

TO INTERIOR ELEVATIONS. TASK LIGHTING SHOWN ON RCP FOR

REFERENCE - SEE RCP SYMBOLS LEGEND.

VERTICAL RETURN AIR GRILLE - REFER TO MECH DWGS.

CEILING LAYOUT - REFER TO MECHANICAL AND ELECTRICAL DWGS FOR

DUCT AND LIGHTING LAYOUT THIS AREA.

EXAM LIGHT AND/OR INJECTOR - PROVIDE ABOVE CLG SUPPORT PER

DET E1/0AI524.

LINE OF 2 HR HORIZONTAL SHAFT ASSEMBLY ABOVE FINISHED CEILING-

SEE DETAIL E1/0AI507.

315.

316.

317.

317A.

318.

319.

320.

321.

322.

323.

324.

325.

326.

327.

328.

329.

330.

331.

332.

333A.

333B.

334.

335.

336.

337.

338.

339.

340.

341.

342.

343.

344.

REFER TO 0AI400 FOR REFLECTED CEILING PLAN SYMBOLS LEGEND

INTERIOR BACK-UP WALL, OPENINGS, SOFFITS, ETC

AROUND PERIMETER OF BUILDING REVISED TO

COORDINATE W/ EWP-06 SKIN COST REDUCTIONS. NEW

AND/OR REVISED PLAN/SECTION/RCP DETAILS AS

INDICATED ON PLANS AND REFLECTED CEILING PLANS.

11 BULL 015A - PRE-AWARD 7/26/2013

12 BULL 015A - VE 7/26/2013

RFI 01719: Shaft size to be revised in bulletin 15a to match opening in structural drawings

RFI 01719: Shaft deleted; bulletin 15a to indicate build out

RFI 01719: Shaft deleted; bulletin 15a to indicate build out

RFI 01719: Shaft size to be revised in bulletin 15a to match opening in structural drawings

RFI 01719: Shaft deleted; bulletin 15a to indicate build out

RFI 01719: Shaft deleted; bulletin 15a to indicate build out

RFI 3704.1: Top track across expansion joint

RFI 3865:

8" Deep, not 10"

RFI 03855: Raise the soffit around the indicator light box to 8'-4".

RFI 3089.2:Revised pocket detail

RFI 04478.1: Raise stainless steel flood gate jamb covers to meet raised soffit.

RFI 04803: Provide bulkhead per detail D3/0AI520 at 8'-10" AFF.

RFI 04811: GWB soffit to be same width as glass screen wall mullion.

RFI 05193: Revise shade pocket to 8" per attached sketch.

RFI 05805:

Provide access panel per attached sketch and spec section.

RFI 5805.1

Accessible panel

RFI 5805.1

Accessible panel

RFI 6487

Control Joint

File details come from the government source that posted it. Updated .