36C25621R0122 ILSM.pdf

PDF 172 KB Posted

Attached to
Z1DA--Project 667-15-104 Renovate and Expand CATH Lab Services
Solicitation number
36C25621R0122
Issued by

About this file

This document outlines requirements for a federal construction contract opportunity with the Department of Veterans Affairs. The Overton Brooks VA Medical Center is seeking proposals to renovate and expand its cardiac catheterization lab for a project estimated between $2 million to $5 million. The solicitation will be issued as a 100% set-aside for service-disabled veteran-owned small businesses. Interested offerors must be verified in the Vendor Information Pages database and registered in the System for Award Management by the September 1, 2021 proposal deadline in order to be considered for the anticipated September award and 808-day performance period. The renovation scope of work will be detailed in the solicitation to be posted on beta.SAM on or around August 2, 2021.

View the file

Other files

File Type Posted
1SD002 Supplemental Drawing Revisions.pdf PDF
SOW Supplement v2.docx DOCX document
Pre-Award RFI Register 66715104 26 Aug 21.docx DOCX document
1SD003 Supplemental Drawing Revisions.pdf PDF
1SD004 Cath Lab LAYDOWN.pdf PDF
36C25621R0122 0004.docx DOCX document
36C25621R0122 0003.docx DOCX document
VHA Directive 1193 COVID 2019 Vaccination August 13 2021.pdf PDF
36C25621R0122 0002.docx DOCX document
66715104 PreBid Site Visit Sign In Sheet.pdf PDF
36C25621R0122 0001.docx DOCX document
1MH17 New Exhaust PH2 Rev 1 08022021.pdf PDF
1SD001 Door Hardware 08022021 v2.pdf PDF
1AS100 Wall Types Rev 1 08022021.pdf PDF
1MH16 New Exhaust PH1 Rev 1 08022021.pdf PDF
1MH14 New HVAC Ductwork PH2 Rev 1 08022021.pdf PDF
1MH13 New HVAC Ductwork PH1 Rev 1 08022021.pdf PDF
36C25621R0122 ICRA .pdf PDF
36C25621R0122 SOW.doc DOC document
36C25621R0122 EXHIBIT E.docx DOCX document
36C25621R0122 JA.pdf PDF
36C25621R0122 Construction Specifications 05272021.pdf PDF
36C25621R0122 RFP.docx DOCX document
36C25621R0122 CRA.pdf PDF
36C25621R0122 EXHIBIT F.docx DOCX document
36C25621R0122 Construction Drawings .pdf PDF
36C25621R0122 WD06182021 Mod 2.txt TXT text file
36C25621R0122 EXHIBIT A.docx DOCX document
36C25621R0122 EXHIBIT D.docx DOCX document
36C25621R0122 EXHIBIT C.docx DOCX document
36C25621R0122 EXHIBIT B.docx DOCX document
36C25621R0122.docx DOCX document
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Description of Interim Life Safety Measures (ILSM) Used

Project #: _667-15-104____ Title: Renovate Cardiac Catherization Lab Date: April 28, 2021

Based on the responses to the evaluation questions, provide a description of the ILSM that will be implemented during the project to compensate for the deficiency or condition. Attach additional sheets if necessary.

-If the contractor has to block an exit, they will hang signage at each location on the floor that directs traffic towards an exit, using a sign stating, “No Exit Due to Construction,” adding directional signage to the next nearest exit, and covering corridor exit signs. The contractor will remove this signage after removing temporary barriers. At no time, will stairwell egress be blocked, without prior notice to COR and Safety Department.

-A corridor width of 44” shall be maintained at all times for patient care and transport.

-When generating dust, the contractor will tape and bag the smoke detectors within the area under construction. The tape and bags will be removed when workers are not present during construction, ie. at night. The boiler plant operator will deactivate and reactivate the smoke detection system to avoid unnecessary alarms as required.

-Fire sprinklers will be turned up and the heads replaced with correct upright pendant heads. Fire system will be de-energized and re-energized each day on the floor during the time the sprinkler heads and pendants are being changed. These outages will be coordinated through the Safety Department.

-Any Life Safety fire detection/alarm section out of service for greater than 4 hours in a 10-hour period, will require a fire watch.

All asbestos and hazardous materials remediation will be covered under a separate ILSM.

Signatures required as indicated below. Completed form will be maintained in the project file.

Project COR: __________________________________ Date: _____________

Reviewers:

1. Safety Manager: _______________________________ Date: _____________

2. Chief Engineer: ____________________________ Date: ____________