S06 - Reference Drawings_556-13-125.pdf

PDF 1022 KB Posted

Attached to
Y1DZ--556-24-122 B132 Pool and HVAC Replacement
Solicitation number
36C25226B0032_01
Issued by

About this file

This document is an architectural floor plan and wall type detail drawing for the renovation of men's and women's showers and a pool filter replacement project at James A. Lovell Federal Health Care Center located at 3001 Green Bay Road, North Chicago, Illinois 60064. The drawing set, prepared by COX Design Associates (Architecture/Planning/Interiors) and KJW&W (Structural/Mechanical/Electrical/Technology/Medical Equipment Solutions), is dated April 17, 2013, and references project number 556-13-125 with sheet designation AS-102.

The ground level floor plan illustrates locker rooms, restrooms, shower facilities, towel rooms, corridors, and stairs with detailed dimensional annotations. The wall type details specify multiple construction assemblies including steel stud framing with sound attenuation insulation and moisture-resistant gypsum board (wall types A1, A2, F1-F6), concrete masonry unit (CMU) construction (types B1-B3), cementitious board with tile finishes (types C1-C2), and field wall tile applications (types T1-T2). Hollow metal door frame details at various scales provide specifications for door installation at metal stud and partition locations. All construction details reference specific structural slab conditions, joint sealants, and firestopping requirements to support the renovation scope.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

FD FD

FD

FD

FD

FDFD

FDFD

FD

FD

FD

FD

FD

FD FD

FD

FD

FD

FD

CG

DCB

A

AS-301

CORRIDOR

JANITOR

TOWEL ROOM

MEN'S

RESTROOM

WOMEN'S

RESTROOM

WOMEN'S

LOCKER ROOM

MEN'S LOCKER

ROOM

MEN'S SHOWERS

108WOMEN'S

SHOWERS

CORRIDOR

STAIRS

AS-201

AS-201

AS-201

AS-201

N

AS-301

B

B

A

104A

AS-201

6' - 1 3/4" 9' - 3 3/4"

6"

4' - 0" 4' - 7 1/2"

1' - 6" 9 3/4"

1' - 6"8 1/2"

5' - 9 3/4"5' - 8 1/2"

9' - 1" 7' - 2 1/4"

3' - 0" 4' - 11 3/4"

2' - 0 1/4"2' - 0"

/4

/4

"AS-201

AS-201

4' - 8 1/4" 4' - 8" 10' - 4"

7' - 3" 2' - 3 1/2" 3' - 4" 3' - 5"

/4

/4

MEN'S STAFF

LOCKER

WOMEN'S STAFF

LOCKER

AS-401

AS-201

12 10

/4

3' - 4"

AS-202

AS-202

AS-202

6 4

1' - 7 1/2" 7' - 8 1/2"

AS-202

/4

/2

/4

/2

/4 x

B

B3

C

A2

A2

A

F5 F

A2

C1

C

A2

A

A

C

F5

A2

A 2 A2

A2

A2

A

A1

F3

A1

F3

C

B

B

B

B1

F6

B

F

C1

A

C2

F2

F3

F

F

F3

F

F3

A1

C

F

F2

F

F 2F2

F3

F

A1

F2

F

F3

A

F2

F

F

F2

F

F6

F 6 F3

F

F3

F3

F

F3

A

A

A1

A

F3

F

F

F2

F

F2 F2

F2

F

F

F2

F

F2 F2

A1

F2 F2

F2

F2

F2 F2 F2

F2 F2

F2

F2

F 2F3

F3

F3 F3

F3

F2

F3 F3

F2

F

F2

A

F5

A

A2

A1

F

F

A1

A1

F6

A

F2

F2

F2

F6

A1

A1

B3

T1T 1 T1

T

T1

T1

T1

T

T2

T2

T2

T2

T2

T2

T2

T

T2

T

T1

T2

T

T2

T2

T2

T1

T2

T2

T2

T2

T

T1

T

T1

T

T1

T1

T

T1

T1

T1

T1

T1

T1 T2

T

T

T1

T

T1

T

T1

T

F2

F2

T2

T

T

T1 T1

T1

T

T1

T

T2

T2

A

T

T2

T2

T 1 F

T

T1

T

T2

T

T1

T2

B3

AS-202

AS-202

3' - 2 1/4"

AS-202

/4

/4

/4

/2

/2

/2

6' - 9 3/4"

/4

/2

/2

AS-401

/4

3' - 7 1/4"

3' - 5"

4' - 9 1/4"

4' - 4 1/4"

/2

4' - 0"

/2

4' - 4 3/4"

3' - 6 1/4"

/2

4' - 11 1/2"

3' - 6"4' - 11 1/2"

F6

/4

4' - 0"

3' - 1 3/4"

T1

A AAAAA

A

A

GRAPHIC LEGEND

KEY NOTES

SHEET NOTES

NEW WALL / PARTITION

NEW DOOR

RECESSED FIRE

EXTINGUISHER CABINET

MILLWORK PROVIDED AND

INSTALLED BY CONTRACTOR

EXISTING WALL TO REMAIN

E

FEC

FLOOR PLAN - SYMBOLS LEGEND

F

WALL TYPE

CONSTRUCTION LIMITS

AREA NOT IN CONTRACT

AREA IN CONTRACT

FLOOR DRAINFD

NEW CMU WALL

CORNERGUARD

CGIN-WALL RIGID INSULATION

WITH MAXIMUM THICKNESS

TO FIT WALL CAVITY

SOUND PARTITION

3 5/8" STEEL STUDS @ 16" O.C. W/ 3" SOUND ATTENUATION INSULATION & 5/8" MOISTURE

RESISTANT GYP BD @ EACH FACE. PROVIDE 1HR RATED UL # U465 DESIGN WHERE 1HR

CONSTRUCTION IS INDICATED ON PLANS - SEE LIFE SAFETY PLANS

GYPSUM BOARD PARTITION SCHEDULE

A1

6" STEEL STUDS @ 16" O.C. W/ 6" SOUND ATTENUATION INSULATION & 5/8" MOISTURE

RESISTANT GYP BD @ EACH FACE. PROVIDE 1HR RATED UL # U465 DESIGN WHERE 1HR

CONSTRUCTION IS INDICATED ON PLANS - SEE LIFE SAFETY PLANS

A2

FURRING

DIRECT BONDED 5/8" MOISTURE

RESISTANT GYP BD

F

1 5/8" STEEL STUDS @ 16" OC W/ 5/8"

MOISTURE RESISTANT GYP BD

F1

2 1/2" STEEL STUDS @ 16" OC W/ 5/8"

MOISTURE RESISTANT GYP BD

F2

F3

3 5/8" STEEL STUDS @ 16" OC W/ 3" SOUND

ATTENUATION INSULATION & 5/8" MOISTURE

RESISTANTGYP BD

F4

6" STEEL STUDS @ 16" OC W/ 5/8"

MOISTURE RESISTANT GYP BD

F5

3 5/8" STEEL STUDS @ 16" OC W/ 5/8"

MOISTURE RESISTANTGYP BD

GYPSUM BOARD PARTITION GENERAL NOTES

ALL GYP BD PARTITIONS SHALL BE A1 UNLESS OTHERWISE NOTED ON FLOOR PLANS

GYP BD PARTITION DIMENSIONS ON FLOOR PLAN ARE BASED ON FACE OF FINISHED

PARTITION TO FACE OF FINISHED PARTITION (NOMINAL).

REFER TO GYP BD SPECIFICATION FOR LOCATIONS & TYPE(S) OF GYPSUM BOARD

MATERIAL REQUIRED.

PROVIDE TYPE "X"FIRE RATED GYPSUM BOARD AT ALL FIRE RATED PARTITIONS.

SEAL ALL WALL PENETRATIONS AT PERIMETER AND FIRESTOP ALL FIRE RATED PARTITIONS.

1.

2.

3.

4.

5. REFERENCE "LIFE SAFETY PLANS" FOR WALL RATINGS

FLOOR PLAN KEYED NOTES

INFILL PREVIOUS DOOR LOCATION WITH WALL TYPE THAT MATCHES ADJACENT FIRE

RATING AND FINISH.

2 PATCH EXISTING WALL AS REQUIRED TO MATCH EXISTING ADJACENT WALL CONSTRUCTION.

5 5/8" CMU WALLB1

7 5/8" CMU WALLB2

3 PATCH EXISTING FLOORING TO MATCH ADJACENT AND PREPARE FOR NEW POOL FILTRATION

EQUIPMENT. REFERENCE XJ SHEETS

4 PROVIDE STEAM CHASE

5 PROVIDE RIGID INSULATION

6 PROVIDE PRIVACY GLASS AT LOCATION

7 SINGLE SIDED BULLNOSE CMU AT OPENING

12" CMU WALLB3

3 5/8" STEEL STUDS @ 16" O.C. W/ 3" SOUND ATTENUATION INSULATION & 1/2" CEMENTIOUS BD @

EACH FACE.

C1

6" STEEL STUDS @ 16" O.C. W/ 6" SOUND ATTENUATION INSULATION & 5/8"

CEMENTIOUS BD @ EACH FACE.

C2

7/8" STEEL HAT CHANNEL @ 16" OC W/ 5/8"

MOISTURE RESISTANTGYP BD

F6

TILING

FIELD WALL TILE (CT-1)T1 FIELD WALL TILE (CT-2)T2

A. DIMENSIONS ON FLOOR PLAN ARE BASED ON FACE OF FINISHED WALL TO FACE OF FINISHED

WALL (NOMINAL)

B. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.

C. MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL SPACES IN THE BUILDING NOT AFFECTED BY

THIS WORK. COORDINATE WITH OWNER AND DISRUPTION IN SERVICES REQUIRED TO

PERFORM WORK OR TO MODIFY EXISTING PIPING, DUCTWORK, OR ANY ASSOCIATED

EQUIPMENT.

D. REFER TO SHEET 1-AS601 FOR ROOM FINISH SCHEDULE AND NOTES. REFER TO SHEET 1-

AS602 FOR DOOR SCHEDULES, DOOR TYPES, AND NOTES.

F.

G.

IN-WALL SUPPORT BLOCKING TO BE PROVIDED AT ALL DOOR WALL STOP LOCATIONS PER

DETAIL 5/1-A17.

H.

HILTI SPEED SLEEVE OR APPROVAL EQUAL REQUIRED FOR CONDUIT AND PIPING

PENETRATIONS THROUGH FIRE RATED WALLS.

I.

ALL WET AREAS TO RECEIVE NEW TILE FLOORING AS INDICATED ON THE ROOM FINISH

SCHEDULE AND ARE TO RECEIVE A WATERPROOFING MEMBRANE

DEMOLITION AS REQUIRED FOR ABATEMENT IS TO BE RECONSTRUCTED BY CONTRACTOR AS

REQUIRED TO MATCH ADJACENT CONDITIONS

J. ALL EXISTING FLOOR DEMOLITION AREA TO BE SEALED AND CAPPED BELOW THE FINISH

FLOOR EXISTING ELEVATION.

9201 West Broadway

Fax: 763.315.7920 Tel: 763.315.7900 Toll Free: 800.233.9513 Brooklyn Park, MN 55445

132 RHC CAW

o n e ei g h th i n ch o n e fo o t

B

C

D

E

F th re e in ch es o n e fo o t o n e an d o n e h al f in ch es o n e fo o t o n e in ch o n e fo o t th re e q u ar te rs i n ch o n e fo o t o n e h al f in ch o n e fo o t th re e ei g h th s in ch o n e fo o t o n e q u ar te r in ch o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Location

Building Number Checked

Date

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

Office of Construction and Facilities Management

Project Name

A

Department of Veterans Affairs

CONSULTANTS: ARCHITECT/ENGINEERS:

Approved: Assistant Director

Approved: Service Chief

Approved: Chief, Bio-Med

Approved: Chief, IT

Approved: Chief, Safety

Approved: Chief of Staff

Approved: Service Chief

Approved: Chief, EMS

Approved: Chief, M&O

Approved: Chief

Approved: Chief, Engineering

Approved: Service Chief

Approved: Chief, Infection Control

Approved: Chief, Police

Approved: Chief

INTERIORS

Austin, Texas 78746 coxdesign@austin.rr.com

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 - 327 - 4149

COX DESIGN ASSOCIATES

PLANNING

F:512 - 327 - 7679

Austin

Chicago, IL 60605 345 N. Canal St. Suite 701

T:312 - 698 - 3880 F:312 - 454 - 9439

Chicago bcox@coxltd.com

STRUCTURAL | MECHANICAL | ELECTRICAL

TECHNOLOGY | MEDICAL EQUIPMENT SOLUTIONS

231 SOUTH LASALLE STREET, SUITE 600CHICAGO, IL 60604312.294.0501FAX: 312.294.0003www.kjww.com

17 APRIL 2013

AS-102

FIRST FLOOR - FLOOR PLAN

15 JAN. 2014

RENOVATE MEN'S AND

WOMEN'S SHOWERS &

REPLACE POOL FILTER

JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, IL 60064

556-13-125

SCALE: 1/4" = 1'-0" RE:1 /AS-301

GROUND LEVEL - FLOOR

PLAN

03 JAN 2014ADA CLEARANCES1

06 JAN 2014STAFF LOCKERS2

15 JAN 2014MEN'S RESTROOM LAYOUT, DOOR LOCATION, ADA LOCKERS3

PLAN

SECTION

SECTION

BOTTOM OF STRUCTURAL SLAB

SOUND ATTENUATION BATTS

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

SOUND ATTENUATION BATTS

MOISTURE RESISTANT GYPSUM

BOARD WITH FINISH

SOUND ATTENUATION BATTS

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

TOP OF STRUCTURAL SLAB

METAL STUD RUNNER TRACK

JOINT SEALANT, FIRESTOPPING

SEALANT WHERE REQUIRED

METAL STUD SPACED 16"O.C.

3 5/8" STEEL STUDS @ 16" O.C. W/ 3" SOUND

ATTENUATION INSULATION & 5/8" MOISTURE RESISTANT

GYP BD @ EACH FACE. PROVIDE 1HR RATED UL # U465

DESIGN WHERE 1HR CONSTRUCTION IS INDICATED ON

PLANS

A1

6" STEEL STUDS @ 16" O.C. W/ 6" SOUND

ATTENUATION INSULATION & 5/8" MOISTURE

RESISTANT GYP BD @ EACH FACE. PROVIDE 1HR

RATED UL # U465 DESIGN WHERE 1HR

CONSTRUCTION IS INDICATED ON PLANS

A2

METAL STUD RUNNER TRACK

SECTION

CEILING WHERE SCHEDULE

ON FINISH SCHEDULE

SOUND ATTENUATION BATTS

MOISTURE RESISTANT GYPSUM

BOARD WITH FINISH

METAL STUD SPACED 16"O.C.

METAL STUD SPACED 16"O.C.

PLAN

SECTION

SECTION

BOTTOM OF STRUCTURAL SLAB

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

SOUND ATTENUATION BATTS

MOISTURE RESISTANT GYPSUM

BOARD WITH FINISH

SOUND ATTENUATION BATTS

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

TOP OF STRUCTURAL SLAB

METAL STUD RUNNER TRACK

JOINT SEALANT

METAL STUD SPACED 16"O.C.

1 5/8" STEEL STUDS @ 16" OC W/ 5/8"

MOISTURE RESISTANT GYP BD

2 1/2" STEEL STUDS @ 16" OC W/ 5/8"

MOISTURE RESISTANT GYP BD

3 5/8" STEEL STUDS @ 16" OC W/ 3" SOUND

ATTENUATION INSULATION & 5/8" MOISTURE

RESISTANT GYP BD

3 5/8" STEEL STUDS @ 16" OC W/ 5/8" MOISTURE

RESISTANT GYP BD

F1

METAL STUD RUNNER TRACK

SECTION

CEILING WHERE SCHEDULE

ON FINISH SCHEDULE

SOUND ATTENUATION BATTS

MOISTURE RESISTANT GYPSUM

BOARD WITH FINISH

METAL STUD SPACED 16"O.C.

METAL STUD SPACED 16"O.C.

F2

F3

F4

FINISH SIDE

6" STEEL STUDS @ 16" OC W/ 5/8" MOISTURE

RESISTANT GYP BD

F5

PLAN

SECTION

SECTION

BOTTOM OF STRUCTURAL SLAB

EXISTING SUBSTRATE

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

TOP OF STRUCTURAL SLAB

FURRING METAL HAT CHANNEL

JOINT SEALANT

7/8" STEEL HAT CHANNEL @ 16" OC W/ 5/8" MOISTURE

RESISTANT GYP BD

F6

SECTION

CEILING WHERE SCHEDULE

ON FINISH SCHEDULE

FINISH SIDE

EXISTING SUBSTRATE

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

FURRING METAL HAT CHANNEL

EXISTING SUBSTRATE

MOISTURE RESISTANT GYPSUM

BOARD WITH FINISH

FURRING METAL HAT CHANNEL

EXISTING SUBSTRATE

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

FURRING METAL HAT CHANNEL

PLAN

SECTION

SECTION

BOTTOM OF STRUCTURAL SLAB

EXISTING STRUCTURE

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

TOP OF STRUCTURAL SLAB

JOINT SEALANT

F DIRECT BONDED 5/8" MOISTURE RESISTANT

GYP BD

SECTION

CEILING WHERE SCHEDULE

ON FINISH SCHEDULE

FINISH SIDE

MOISTURE RESISTANT GYP BD BONDING COMPOUND

EXISTING STRUCTURE

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

MOISTURE RESISTANT GYP BD BONDING COMPOUND

EXISTING STRUCTURE

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

MOISTURE RESISTANT GYP BD BONDING COMPOUND

EXISTING STRUCTURE

MOISTURE RESISTANT GYPSUM BOARD WITH FINISH

MOISTURE RESISTANT GYP BD BONDING COMPOUND

4 7/8"PER PLAN

STL. DOOR FRAME

GROUT SOLID

CONTINUOUS

SEALANT EACH SIDE

DOUBLE JAMB STUDS

TYPICAL

1 LAYER 5/8" MOISTURE

RESISTANT GWB

EACH SIDE

BATT INSUL.

1 15/16" 1 15/16"

15/32"

/3

/8

1 15/16" 1 15/16"

STL. DOOR FRAME

GROUT SOLID

MOISTURE

RESISTANT GYP BD

/3

/8

1 15/16" 1 15/16"

1/2" 15/32"

STL. DOOR FRAME

GROUT SOLID

CONTINUOUS

SEALANT EACH SIDE

DOUBLE JAMB STUDS

TYPICAL

1 LAYER 5/8" MOISTURE

RESISTANT GYP. BD.

EACH SIDE

1 LAYER 5/8" MOISTURE

RESISTANT GYP BD

EACH SIDE

STEEL SIDE W/ FULL

BATT INSULATION

PLAN

SECTION

SECTION

BOTTOM OF STRUCTURAL SLAB

CMU

TOP OF STRUCTURAL SLAB

JOINT SEALANT, FIRESTOPPING

SEALANT WHERE REQUIRED

CMU

5 5/8" CMUB1

7 5/8" CMUB2

SECTION

CEILING WHERE SCHEDULE

ON FINISH SCHEDULE

CMU

CMU

12" CMUB3

PLAN

SECTION

SECTION

BOTTOM OF STRUCTURAL SLAB

SOUND ATTENUATION BATTS

CEMENTIOUS BOARD WITH TILE FINISH

SOUND ATTENUATION BATTS

CEMENTIOUS BOARD WITH TILE

FINISH

SOUND ATTENUATION BATTS

CEMENTIOUS BOARD WITH TILE FINISH

TOP OF STRUCTURAL SLAB

METAL STUD RUNNER TRACK

JOINT SEALANT, FIRESTOPPING

SEALANT WHERE REQUIRED

METAL STUD SPACED 16"O.C.

3 5/8" STEEL STUDS @ 16" O.C. W/ 3" SOUND ATTENUATION

INSULATION & 1/2" CEMENTIOUS BD @ EACH FACE.

C1

6" STEEL STUDS @ 16" O.C. W/ 6" SOUND ATTENUATION

INSULATION & 5/8" CEMENTIOUS BD @ EACH FACE.

C2

METAL STUD RUNNER TRACK

SECTION

CEILING WHERE SCHEDULE

ON FINISH SCHEDULE

SOUND ATTENUATION BATTS

CEMENTIOUS BOARD WITH TILE

FINISH

METAL STUD SPACED 16"O.C.

METAL STUD SPACED 16"O.C.

PLAN

SECTION

SECTION

BOTTOM OF CEILING

SUBSTRATE PARTITION OR FURRING WALL TYPE

FINISH TILE

TOP OF STRUCTURAL SLAB

JOINT SEALANT

T1 FIELD WALL TILE (CT-1)

SECTION

CEILING WHERE SCHEDULE

ON FINISH SCHEDULE

FINISH SIDE

TILE BONDING COMPOUND

SUBSTRATE PARTITION OR FURRING WALL TYPE

FINISH TILE

TILE BONDING COMPOUND

SUBSTRATE PARTITION OR FURRING WALL TYPE

FINISH TILE

TILE BONDING COMPOUND

SUBSTRATE PARTITION OR FURRING WALL TYPE

FINISH TILE

TILE BONDING COMPOUND

T2 FIELD WALL TILE (CT-2)

9201 West Broadway

Fax: 763.315.7920 Tel: 763.315.7900 Toll Free: 800.233.9513 Brooklyn Park, MN 55445

132 RHC CAW

o n e ei g h th i n ch o n e fo o t

B

C

D

E

F th re e in ch es o n e fo o t o n e an d o n e h al f in ch es o n e fo o t o n e in ch o n e fo o t th re e q u ar te rs i n ch o n e fo o t o n e h al f in ch o n e fo o t th re e ei g h th s in ch o n e fo o t o n e q u ar te r in ch o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Drawing Title

Location

Building Number Checked

Date

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

Office of Construction and Facilities Management

Project Name

A

Department of Veterans Affairs

CONSULTANTS: ARCHITECT/ENGINEERS:

Approved: Assistant Director

Approved: Service Chief

Approved: Chief, Bio-Med

Approved: Chief, IT

Approved: Chief, Safety

Approved: Chief of Staff

Approved: Service Chief

Approved: Chief, EMS

Approved: Chief, M&O

Approved: Chief

Approved: Chief, Engineering

Approved: Service Chief

Approved: Chief, Infection Control

Approved: Chief, Police

Approved: Chief

INTERIORS

Austin, Texas 78746 coxdesign@austin.rr.com

ARCHITECTURE

5121 Bee Caves Road, Suite 203

T:512 - 327 - 4149

COX DESIGN ASSOCIATES

PLANNING

F:512 - 327 - 7679

Austin

Chicago, IL 60605 345 N. Canal St. Suite 701

T:312 - 698 - 3880 F:312 - 454 - 9439

Chicago bcox@coxltd.com

STRUCTURAL | MECHANICAL | ELECTRICAL

TECHNOLOGY | MEDICAL EQUIPMENT SOLUTIONS

231 SOUTH LASALLE STREET, SUITE 600CHICAGO, IL 60604312.294.0501FAX: 312.294.0003www.kjww.com

17 APRIL 2013

JAMES A. LOVELL FHCC

3001 GREEN BAY ROAD

NORTH CHICAGO, IL 60064

AS-501

WALL TYPES

4 APRIL 2013

RENOVATE MEN'S AND

WOMEN'S SHOWERS &

REPLACE POOL FILTER

556-13-125

SCALE: 3" = 1'-0"

HOLLOW METAL DOOR

FRAME @ MTL STUD

SCALE: 3" = 1'-0"

HOLLOW METAL DOOR

FRAME JAMB

SCALE: 3" = 1'-0"

HOLLOW METAL DOOR

FRAME JAMB @

PARTITION