S06 001.Att4a S02_Att17a DWGS_Healthcare Bldgs 113_128_200_217_221_228.pdf
PDF 20 MB Posted
- Attached to
- Z1DA--578-26-004: IDIQ ACM Abatement Base
- Solicitation number
- 36C25226B0020
About this file
This is a Statement of Conditions (SOC) documentation package for the Edward Hines, Jr. VA Hospital in Hines, Illinois, detailing fire and life safety conditions across multiple buildings and floors. The document serves as a comprehensive record of building occupancies, fire protection systems, smoke compartmentalization, and emergency egress requirements in compliance with the 2024 NFPA 101 Life Safety Code and 2022 NFPA 80 standards.
The facility encompasses six primary buildings (113, 128, 200, 217, 221, and 228) with varying occupancy classifications including health care, ambulatory care, business, industrial, and storage uses across basement through seventeenth floors. Key fire protection features include fully sprinklered systems utilizing quick response and standard response sprinklers per NFPA 13 and 14, with quick response types predominating in patient care areas at 0.10 GPM/1500 sq. ft. density. Fire barrier classifications include 2-hour fire and smoke zone barriers for occupancy separations and stairwells of four or more stories, 1-hour fire barriers for hazardous room enclosures and stairwells of three stories or less, and non-rated smoke barriers for compartmentalization. Fire alarm systems comply with 2019 NFPA 72 standards and include private mode audible and visible notification devices. The facility maintains approved equivalencies from The Joint Commission including oversized protective plates on fire-rated doors, extended business occupancy dead-end corridors beyond 50 feet, and modular building construction separation in Building 221. All drawings include detailed partition legends, suite designations, smoke zone boundaries, and fire alarm/sprinkler zone demarcations. Total documented occupancy across all measured spaces is 1,454,624 square feet.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EW
FAAP
FACP
FIRE EXTINGUISHER
EXIT SIGN
EMERGENCY LIGHT
FIRE ALARM STATION
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
AUTOMATED EXTERNAL DEFIBRILLATOR
F
AED
EYEWASH STATION
SPRINKLER SYSTEM RISER
SH SHOWER STATION
SIAMESE (FIRE DEPARTMENT CONNECTION)
FIRE HOSE VALVEFHV
SYMBOLS LIST
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL:
DUCTS:
DOORS:
WALL:
DUCTS:
PENETRATIONS:
DOORS:
SUITE DESIGNATION
2-HOUR FIRE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF
4 OR MORE STORIES.
2-HOUR FIRE AND SMOKE ZONE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION
OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.
1-HOUR FIRE BARRIER
THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPARATIONS, HAZARDOUS ROOM
ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.
SMOKE ZONE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS
OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND
THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.7.6) SMOKE
ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED
TO BE OF A 1/2 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
(COLOR #5)
(COLOR #4)
(COLOR #1)
(COLOR #2)
(COLOR #3)
NOTE: ALL CODE REFERENCES ARE PER THE 2024 EDITION OF NFPA 101 LIFE SAFETY CODE AND 2022 EDITION OF NFPA 80. FEDERAL FACILITIES FOLLOW 2024 LIFE SAFETY CODE.
DOORS: 1. NON-LABELED FRAME PERMITTED IF AREA IS SPRINKLERED (NFPA 101 18.3.6.3.1 & 19.3.6.3.15)
2. NON-RATED DOORS PERMITTED IF AREA IS SPRINKLERED (NFPA 101
18.3.6.3.1, 19.3.6.3.2(2))
3. 20-MINUTE OR 1-3/4" SOLID WOOD CORE IF AREA IS NOT SPRINKLERED (NFPA 101 19.3.6.3.1)
4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER, SINK, AND SIMILAR ROOMS (NFPA 101 18.3.6.3.6 &
19.3.6.3.11)
5. SELF-CLOSING NOT REQUIRED (NFPA 101 18.3.6.3.12 & 19.3.6.3.11)
6. MAXIMUM 1/8" GAP (JOINT COMMISION)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)
8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.6.3.13 & 19.3.6.3.12)
9. TRANSFER GRILLES NOT PERMITTED EXCEPT TOILETS, SHOWER, SINK, AND SIMILAR ROOMS
(NFPA 101 18/19.3.6.4)
10. SWING IN ANY DIRECTION IF FEWER THAN 50 OCCUPANTS (NFPA 101 7.2.1.4.2)
(COLOR #30)
NON-RATED SMOKE ZONE PARTITION
DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER ZONE.
BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY THE FIRE
DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99 AND PRIVATE MODE AUDIBLE
REQUIREMENTS OF SECTION 18.4.5 OF NFPA 72.
WALL:
DUCTS:
PENETRATIONS:
DOORS:
HEALTH CARE OCCUPANCY CORRIDORS
IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED
TO LIMIT TRANSFER OF SMOKE.
IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALLS SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. EXISTING CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 18/19.3.6.2
PENETRATIONS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO BE
FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO
BE FILLED ON THE TOP OF THE FLOOR.
1. LABELED FRAMES (NFPA 101 8.3.3.3.2)
2. LABELED 1 1/2 HOUR DOOR (NFPA 101 TABLE 8.3.3.2.2)
3. VISION PANEL PERMITTED* UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE 8.3.3.2.2).
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED IF ASTRAGALS ARE PRESENT** (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" HIGH PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)
10. SWING IN DIRECTION OF EGRESS (NFPA 101 7.2.1.4.2).
11. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 80 5.2.4.1)
* VISION PANELS REQUIRED FOR DOORS IN NEW HORIZONTAL EXITS (NFPA 101 18.2.2.5.6)
** IN DOOR PAIRS, ASTRAGALS NOT PERMITTED TO INHIBIT FREE USE OF EITHER LEAF
(NFPA 80 6.4.7.1)
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND SMOKE
DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE
COMPARTMENTS ARE PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT
EACH COMPARTMENT.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO BE
FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO
BE FILLED ON THE TOP OF THE FLOOR.
1. LABELED FRAMES (NFPA 101 8.3.3.3.2)
2. LABELED 1 1/2 HOUR DOOR (NFPA 101 TABLE 8.3.3.2.2)
3. VISION PANEL PERMITTED* UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE 8.3.3.2.2)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED IF ASTRAGALS ARE PRESENT** (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" HIGH PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5.1)
10.SWING IN DIRECTION OF EGRESS (NFPA 101 7.2.1.4.2).
11. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 80 5.2.4.1)
* VISION PANELS REQUIRED FOR DOORS IN NEW HORIZONTAL EXITS (NFPA 101 18.2.2.5.6)
** IN DOOR PAIRS, ASTRAGALS NOT PERMITTED TO INHIBIT FREE USE OF EITHER LEAF
(NFPA 80 6.4.7.1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED
TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY
REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.
1. LABELED FRAMES (NFPA 101 8.3.3.3.2)
2. LABELED 3/4 OR 1-HOUR* DOOR (NFPA 101 TABLE 8.3.3.2.2)
3. VISION PANEL PERMITTED UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE
8.3.3.2.2)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED IF ASTRAGALS ARE PRESENT (NFPA 80
6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" HIGH PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)
10.SWING IN DIRECTION OF EGRESS (NFPA 101 7.2.1.4.2)
11. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 80 5.2.4.1)
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR LESS.
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE DAMPERS
ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE PROTECTED
BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE TO
BE FILLED ON BOTH SIDES OF THE WALL.
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR 1-3/4" SOLID WOOD CORE (NFPA 101 18/19.3.7.6)
3. VISION PANEL PERMITTED UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE
8.3.3.2.2)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18/19.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18/19.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4.1)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 180 5.2.4.1)
WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
NO MINIMUM REQUIREMENTS.
NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED
CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED
WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.
NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING
IN AN EMERGENCY.
(COLOR #30)
(COLOR #2)
HEALTHCARE AREA OPEN TO CORRIDOR WITH 24/7
SUPERVISION - NO SMOKE DETECTION REQUIRED.
(COLOR #3)
HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE
DETECTION PROVIDED.
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
(COLOR #230)
(COLOR #4)
NON-RATED SMOKE BARRIER
SUBSTANTIAL WALLS AND DOORS TO SUBDIVIDE BUILDING SPACES FOR THE PURPOSE
OF RESTRICTING THE MOVEMENT OF SMOKE.
WALL: EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: SMOKE DAMPERS ARE NOT REQUIRED WHERE STEEL DUCTS PENETRATE SMOKE
BARRIERS FORMING A COMMUNICATING SPACE SEPARATION.
PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH MATERIALS TO PREVENT THE
TRANSFER OF SMOKE. USE OF LISTED FIRE STOP MATERIALS IS NOT REQUIRED.
DOORS: 1. NON-LABELED FRAME (NFPA 101 8.5)
2. NON-FIRE-RATED DOOR (NFPA 101 8.5)
3. NO GRILLES OR LOUVERS ARE PERMITTED (NFPA 101 8.5.4.1)
4. POSITIVE LATCHING HARDWARE IS REQUIRES (NFPA 101 8.5.4.3)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.5.4.3)
6. MAXIMUM 3/4” UNDERCUT (NFPA 101 8.5.4.1)
7. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1)
8. SWING IN ANY DIRECTION IF FEWER THAN 50 OCCUPANTS (NFPA 101 7.2.1.4.2)
9. WINDOW ASSEMBLIES ARE NOT REQUIRED TO BE FIRE RATED (NFPA 101 7.2.1.4.2)
WALL:
DUCTS:
DOORS:
SMOKE-RESISTIVE HAZARDOUS ROOM ENCLOSURE
(COLOR #230) IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT
TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY
TERMINATE AT THE CEILING PER NFPA 101 8.4.2(3). IF THE ROOM DOES NOT HAVE A
SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE RATING AND SHALL
EXTEND TO THE DECK ABOVE PER NFPA 101 19.3.2.1.2.
STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS OR SMOKE DAMPERS.
ALL PENETRATIONS ARE SEALED WITH MATERIALS TO PREVENT THE TRANSFER OF
SMOKE. USE OF LISTED FIRESTOP MATERIALS IS NOT REQUIRED.
1. NON-LABELED FRAME (NFPA 101 8.4.2)
2. CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE. DOES NOT APPLY TO
TOILET, BATH, SHOWER, SINK OR SIMILAR ROOMS (NFPA 18/19.3.6.3.1,
18/19.3.6.3.2)
3. POSITIVE LATCHING REQUIRED IF OPENING TO HEALTH CARE CORRIDOR (NFPA
101 18/19.3.6.3.5)
4. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.4.3.5)
5. MAXIMUM 1/8" GAP (NFPA 101 8.4.3.4 & NFPA 80 6.3.1.7)
6. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.4.3.4 & NFPA 80 4.8.4.1)
7. PROTECTIVE PLATES PERMITTED TO BE UNLIMITED IN HEIGHT
8. SWING IN ANY DIRECTION IF FEWER THAN 50 OCCUPANTS (NFPA 101 7.2.1.4.2)
PENETRATIONS:
(COLOR #30)
EXIT STAIRWELL/PASSAGEWAY
OCCUPANCY/SMOKE ZONE BOUNDARY
FIRE/SMOKE BARRIER
DESCRIPTION
113,128, 200, 217, 221, 228
23400
DATEREVISIONS: NUMBER
DRAFT SOC 4/08/2024
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
KC LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C CONSULTANTS,
JLB DJB
HINES, ILLINOIS
EDWARD HINES, JR. VA
STATEMENT OF CONDITIONS
DOCUMENTATIONEdward Hines, Jr.
VA Hospital 5000 5th Ave
Hines, IL 60141 Checked by Drawn by
Dwg. of 64
SOC X-1
578-24-002
FINAL SOC
06/19/2024
6/19/2024
OCCUPANCY TABLE
APPLICABLE CODES AND STANDARDS: FIRE SPRINKLER SYSTEM:
1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.
2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13 - 3.3.4.16).
3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 225 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).
4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15
GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).
5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT. DENSITY.
6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13 - 10.2.5.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS IN SMALL ROOMS (800 SQ. FT. MAXIMUM) SHALL NOT
EXCEED 9' FROM ANY SINGLE WALL (NFPA 13 - 10.2.5.2.3).
7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13 - 12.1.10.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE 2019 EDITION ON NFPA 13. SPRINKLERS NOT REQUIRED UNDER
NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13 - 9.5.5.3.1).
8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13 - 10.2.6.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13 - 10.2.6.1.2).
9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA 13 - 9.5.6.1).
10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE PER NFPA 13 - 9.2.5(2).
11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.1.2 AND FIGURE 10.2.7.1.2(a).
12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.2.2 AND FIGURE 10.2.7.2.2.
SUITES:
1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND TO DEFINE THE END OF PUBLIC EXIT
CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE MAY DIRECT OCCUPANTS INTO A SUITE TO REACH AN EXIT.
2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.
3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:
A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)
B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION - 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B) D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION - 10,000 SQ. FT. (NFPA
101 - 19.2.5.7.2.3.C)
4. PATIENT CARE NON - SLEEPING SUITES:
A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)
B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.3)
5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6
OF NFPA 101.
FIRE ALARM SYSTEM:
1. THE FIRE ALARM SYSTEM WAS DESIGNED TO 2019 EDITION OF NFPA 72, NATIONAL FIRE ALARM CODE.
2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2018 EDITION.
3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF NFPA
72 - 2019 EDITION.
4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72 - 2019
EDITION.
5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72 - 2019 EDITION.
6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA (NFPA 72 - 17.7.3.2.3.1)
7. SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS MAY
BE SPACED AT MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE (NFPA 72 - 17.7.5.6.1) SMOKE DETECTORS NOT CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 72- 17.7.5.6.
8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF CEILING HEIGHT SHALL HAVE REDUCED SMOKE DETECTOR SPACING
COVERAGE (NFPA 72 - 17.7.3.2.4.2).
9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE
DETECTOR (NFPA 72- 17.7.3.2.1).
10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).
1. THE ORIGINAL BUILDING WAS DESIGNED TO THE 1965 EDITION OF NFPA 101, LIFE SAFETY CODE.
2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW THE LATEST EDITIONS OF NATIONALLY
RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.
3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE CODES AND STANDARDS.
4. OTHER NFPA CODES AND STANDARDS:
A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2018 EDITION
B. NFPA 13 - SPRINKLER SYSTEMS, 2019 EDITION
C. NFPA 14 - STANDPIPE SYSTEMS, 2016 EDITION
D. NFPA 20 - FIRE PUMPS, 2019 EDITION
E. NFPA 25 - WATER-BASED FIRE PROTECTION SYSTEMS 2020 EDITION
F. NFPA 70 - NATIONAL ELECTRIC CODE, 2020 EDITION
G. NFPA 72 - NATIONAL FIRE ALARM CODE, 2019 EDITION
H. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION
I. NFPA 80 - FIRE DOORS, 2019 EDITION
J. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2018 EDITION
K. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2017 EDITION
L. NFPA 99 - HEALTH CARE FACILITIES CODE, 2018 EDITION
M. NFPA 105 - SMOKE DOORS, 2019 EDITION
N. NFPA 110 - EMERGENCY POWER SYSTEMS, 2019 EDITION
O. NFPA 241 - CONSTITUTION AND DEMOLITION, 2019 EDITION
1. EXITS (STAIRWAYS, HORIZONTAL EXITS AND DIRECT EXTERIOR EXIT DOORS), OTHER THAN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS. (GLASS DOORS, VISION PANELS OR ADJACENT WINDOWS) SHALL BE MARKED WITH EXIT SIGNAGE.
(SECTION 7.10.1.2.1 OF NFPA 101-2018 EDITION)
2. DIRECTIONAL SIGNS REQUIRED WHERE DIRECTION OF TRAVEL IS NOT APPARENT IN AN EXIT ACCESS CORRIDOR. (SECTION 7.10.2.1 OF NFPA
101-2018 EDITION)
3. DIRECTIONAL SIGNAGE (EXIT PLACARDS) REQUIRED WITHIN HORIZONTAL COMPONENTS OF EXIT STAIR ENCLOSURES WHERE EGRESS PATH
IS NOT OBVIOUS (SECTIONS 7.10.2.2 AND 7.10.1.2.2 OF NFPA 101-2018 EDITION)
4. MAXIMUM VIEWING DISTANCE TO AN EXIT SIGN IN AN EXIT ACCESS CORRIDOR IS 100 FT. (SECTION 7.10.1.5.2 OF NFPA 101-2018 EDITION)
5. EXIT SIGNS SHALL BE INSPECTED MONTHLY. (SECTION 7.10.9.1 IF NFPA 101-2018 EDITION)
6. DIRECTIONAL SIGNAGE (EXIT PLACARDS OR EXIT SIGNS) WITH OR WITHOUT DIRECTIONAL ARROWS SHOULD BE PROVIDED IN SUITES USED
BY THE GENERAL PUBLIC (LESS THAN 50 TOTAL OCCUPANTS) TO DIRECT THE GENERAL PUBLIC BACK TO THE WAITING AREA. (SECTION
7.10.2.1 OF NFPA 101-2018 EDITION)
7. ROOMS OR SUITES OF ROOMS USED FOR 50 OCCUPANTS OR MORE SHALL BE PROVIDED WITH EXIT SIGNAGE. (SECTIONS 13.2.10.1 AND
3.3.196.2 OF NFPA 101-2018 EDITION)
EXIT SIGN REQUIREMENTS
THE VA HAS ELECTIVE ACCREDITATION WITH THE JOINT COMMISSION (TJC) FOR HEALTH CARE FACILITIES. SEE THE MEMORANDUM OF UNDERSTANDING (EFFECTIVE 4 SEPTEMBER, 2017) BETWEEN THE VA AND TJC FOR IMPLEMENTATION OF TJC ENVIRONMENT OF CARE (EC) AND
LIFE SAFETY (LS) STANDARDS.
THE VA HAS ELECTIVE ACCREDITATION WITH THE LONG-TERM CARE INSTITUTE, INC. (LTCI) FOR COMMUNITY LIVING CENTERS (CLC). SEE THE CLARIFICATION MEMORANDUM (EFFECTIVE MARCH 29, BETWEEN THE VA AND THE LTCI FOR IMPLEMENTATION OF LIFE SAFETY REQUIREMENTS.
THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND APPROVED BY THE JOINT COMMISSION AND APPLY TO ALL BUILDINGS:
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS
2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50 FEET
3. INTERNAL SPRINKLER PIPING CONDITION AND OBSTRUCTION INVESTIGATION.
THE FOLLOWING SITE SPECIFIC EQUIVALENCIES HAVE BEEN APPROVED BY TJC:
1. BUILDING 200 MAIN HOSPITAL
A. LINEAR ACCELERATOR COMMON PATH OF TRAVEL
B. STAIR NO. 1 IS EXIT PASSAGEWAY
2. BUILDING 221 REHABILITATION CENTER
A. MODULAR BUILDING CONSTRUCTION SEPARATION
EQUIVALENCIES
CODE SUMMARY
AND OCCUPANCY TABLE ALL
23400
DATEREVISIONS: NUMBER
DRAFT SOC 4/08/2024
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
KC LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C CONSULTANTS,
JLB DJB
HINES, ILLINOIS
EDWARD HINES, JR. VA
STATEMENT OF CONDITIONS
DOCUMENTATIONEdward Hines, Jr.
VA Hospital 5000 5th Ave
Hines, IL 60141 Checked by Drawn by
Dwg. of 64
SOC X-2
578-24-002
FINAL SOC
06/19/2024
6/19/2024
Building No. Floor Healthcare Ambulatory Health Care Business Industrial Storage Daycare Total
1 4 0 0 99,707 0 0 0 99,707 1 3 0 0 104,344 0 0 0 104,344 1 2 0 0 104,837 0 0 0 104,837 1 1 0 0 129,758 0 0 0 129,758 1 Subtotal 0 0 438,646 0 0 0 438,646
12 3 0 0 5,019 0 0 0 5,019 12 2 0 0 5,024 0 0 0 5,024 12 1 0 0 4,999 0 0 0 4,999 12 Basement 0 0 1,174 0 0 0 1,174 12 Subtotal 0 0 16,216 0 0 0 16,216 13 3 0 0 6,312 0 0 0 6,312 13 2 0 0 6,312 0 0 0 6,312 13 1 0 0 6,396 0 0 0 6,396 13 Basement 0 0 1,426 0 0 0 1,426 13 Subtotal 0 0 20,446 0 0 0 20,446
113 Penthouse 0 0 0 4,009 0 0 4,009 113 2 0 0 26,195 0 0 0 26,195 113 1 26,063 0 0 0 0 0 26,063 113 Subtotal 26,063 0 26,195 4,009 0 0 56,267 128 1 52,567 0 0 0 0 0 52,567 128 Basement 0 0 2,520 0 0 0 2,520 128 Subtotal 52,567 0 2,520 0 0 0 55,087 200 17 0 0 0 3,168 0 0 3,168 200 16 0 0 0 5,838 0 0 5,838 200 15 0 0 0 0 19,859 0 19,859 200 14 0 19,761 0 0 0 0 19,761 200 13 0 19,867 0 0 0 0 19,867 200 12 0 19,881 0 0 0 0 19,881 200 11 19,896 0 0 0 0 0 19,896 200 10 16,637 0 0 0 0 0 16,637 200 9 19,820 0 0 0 0 0 19,820 200 8 19,843 0 0 0 0 0 19,843 200 7 19,791 0 0 0 0 0 19,791 200 6 0 19,920 0 0 0 0 19,920 200 5 0 19,814 0 0 0 0 19,814 200 4 0 0 21,041 0 0 0 21,041 200 3 0 21,058 0 0 0 0 21,058 200 2 70,248 0 0 0 0 0 70,248 200 1 0 101,263 0 0 0 0 101,263 200 Basement 0 88,007 0 0 0 0 88,007 200 Subtotal 166,235 309,571 21,041 9,006 19,859 0 525,712 217 2 57,230 0 0 0 0 0 57,230 217 1 62,907 0 0 0 0 0 62,907 217 Subtotal 120,137 0 0 0 0 0 120,137 221 1 31,276 0 0 0 0 0 31,276 221 Subtotal 31,276 0 0 0 0 0 31,276 228 5 0 0 27,298 0 0 0 27,298 228 4 32,402 0 0 0 0 0 32,402 228 3 0 0 32,392 0 0 0 32,392 228 2 32,395 0 0 0 0 0 32,395 228 1 0 0 40,734 0 0 0 40,734 228 Basement 0 0 25,616 0 0 0 25,616 228 Subtotal 64,797 0 126,040 0 0 0 190,837
GRAND TOTAL 461,075 309,571 651,104 13,015 19,859 0 1,454,624
EX
EX
EX
ZONE 1BZONE 1A
ZONE 1BZONE 1A
EX
EX
EX
FACP
F
F
F
F
F
F
A E
D
A E
D
F FAAP
FIRST FLOOR
HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
SUITE DESCRIPTIONS
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
BUILDING 113
BLIND REHAB
FIRST FLOOR
BUILDING 113
N
23400
DATEREVISIONS: NUMBER
DRAFT SOC 4/08/2024
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
KC LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C CONSULTANTS,
JLB DJB
HINES, ILLINOIS
EDWARD HINES, JR. VA
STATEMENT OF CONDITIONS
DOCUMENTATIONEdward Hines, Jr.
VA Hospital 5000 5th Ave
Hines, IL 60141 Checked by Drawn by
Dwg. of 64
113SOC-1
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
578-24-002
APPROVED SITE EQUIVALENCIES
BUILDING 200 - MAIN HOSPITAL
1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.
2. STAIR NO. 1 EXIT PASSAGEWAY.
BUILDING 221 - REHABILITATION CENTER
1. MODULAR BUILDING CONSTRUCTION SEPARATION.
FINAL SOC
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
06/19/2024
6/19/2024
AutoCAD SHX Text
ENTRANCE CANOPY
AutoCAD SHX Text
COURTYARD
AutoCAD SHX Text B1A112
AutoCAD SHX Text B1A113
AutoCAD SHX Text B1A116
AutoCAD SHX Text B1A115
AutoCAD SHX Text B1A114
AutoCAD SHX Text B1A120
AutoCAD SHX Text B1A121
AutoCAD SHX Text B1A1117
AutoCAD SHX Text B1A120
AutoCAD SHX Text B1A127
AutoCAD SHX Text B1A128
AutoCAD SHX Text B1A129
AutoCAD SHX Text B1A123
AutoCAD SHX Text B1A131
AutoCAD SHX Text B1B100
AutoCAD SHX Text B1B100
AutoCAD SHX Text B1B103
AutoCAD SHX Text B1B106
AutoCAD SHX Text B1B107
AutoCAD SHX Text B1B109
AutoCAD SHX Text B1C4
AutoCAD SHX Text B1B106
AutoCAD SHX Text
B1ST2-1
AutoCAD SHX Text
B1ST2-2
AutoCAD SHX Text B1B114
AutoCAD SHX Text B1B115
AutoCAD SHX Text B1B116
AutoCAD SHX Text B1B117
AutoCAD SHX Text B1B119
AutoCAD SHX Text B1B122
AutoCAD SHX Text B1B121
AutoCAD SHX Text B1B124
AutoCAD SHX Text B1B127
AutoCAD SHX Text B1B130
AutoCAD SHX Text B1B132
AutoCAD SHX Text B1B129
AutoCAD SHX Text B1C6-2
AutoCAD SHX Text B1C6-3
AutoCAD SHX Text B1B136
AutoCAD SHX Text B1B137
AutoCAD SHX Text B1B139
AutoCAD SHX Text B1B138
AutoCAD SHX Text B1B141
AutoCAD SHX Text B122
AutoCAD SHX Text B121
AutoCAD SHX Text 1B1B125
AutoCAD SHX Text B1B143
AutoCAD SHX Text B1B148-1
AutoCAD SHX Text B127
AutoCAD SHX Text B1B148-3
AutoCAD SHX Text B1B151
AutoCAD SHX Text B1A152
AutoCAD SHX Text B1C7
AutoCAD SHX Text
B1ST1-1
AutoCAD SHX Text
B1ST1-2
AutoCAD SHX Text B1A132
AutoCAD SHX Text B1A133
AutoCAD SHX Text B1C3-1
AutoCAD SHX Text B1C3-2
AutoCAD SHX Text B1B101
AutoCAD SHX Text B1B104
AutoCAD SHX Text B1B108
AutoCAD SHX Text B1B105
AutoCAD SHX Text B1B110
AutoCAD SHX Text B1B112
AutoCAD SHX Text B109
AutoCAD SHX Text B110
AutoCAD SHX Text B1B120B
AutoCAD SHX Text B1B120
AutoCAD SHX Text B1B123
AutoCAD SHX Text B1B126
AutoCAD SHX Text B1B128
AutoCAD SHX Text B1B125
AutoCAD SHX Text B1B131
AutoCAD SHX Text B1B133
AutoCAD SHX Text B1B124
AutoCAD SHX Text B1B134
AutoCAD SHX Text B1B144
AutoCAD SHX Text B128
AutoCAD SHX Text B1B146
AutoCAD SHX Text B1B147
AutoCAD SHX Text B129
AutoCAD SHX Text B1C8-1
AutoCAD SHX Text B1C8-2
AutoCAD SHX Text B1B150
AutoCAD SHX Text B1B152
AutoCAD SHX Text B1A151
AutoCAD SHX Text B1A140
AutoCAD SHX Text B1A139
AutoCAD SHX Text B1A138
AutoCAD SHX Text B1A134
AutoCAD SHX Text B1A143
AutoCAD SHX Text B1A144
AutoCAD SHX Text B1A133
AutoCAD SHX Text B1A128
AutoCAD SHX Text B1A134
AutoCAD SHX Text B1C2
AutoCAD SHX Text B1A113
AutoCAD SHX Text B1A110
AutoCAD SHX Text B1A111
AutoCAD SHX Text B1C1-1
AutoCAD SHX Text B1C1-2
AutoCAD SHX Text B1A122
AutoCAD SHX Text B1A109
AutoCAD SHX Text B1A116
AutoCAD SHX Text B1A124A
AutoCAD SHX Text B1A126
AutoCAD SHX Text B1A135
AutoCAD SHX Text B1A138
AutoCAD SHX Text B1A140
AutoCAD SHX Text B1A141
AutoCAD SHX Text B1C9
AutoCAD SHX Text B1A110
AutoCAD SHX Text B1A107
AutoCAD SHX Text B1A105
AutoCAD SHX Text B1A108
AutoCAD SHX Text B1A106
AutoCAD SHX Text B1A109
AutoCAD SHX Text B1A100-1
AutoCAD SHX Text B1A100-2
AutoCAD SHX Text A151
AutoCAD SHX Text A149
AutoCAD SHX Text B1A160-2
AutoCAD SHX Text A150
AutoCAD SHX Text A149
AutoCAD SHX Text B1A166-1
AutoCAD SHX Text B1A162
AutoCAD SHX Text B1A161
AutoCAD SHX Text B1A159
AutoCAD SHX Text A143
AutoCAD SHX Text A144
AutoCAD SHX Text B1A156
AutoCAD SHX Text B1A150
AutoCAD SHX Text B1A148
AutoCAD SHX Text B1A147
AutoCAD SHX Text B1A145
AutoCAD SHX Text B1A103
AutoCAD SHX Text B1A104
AutoCAD SHX Text B1A114A
AutoCAD SHX Text B1A118A
AutoCAD SHX Text B1A125A
AutoCAD SHX Text B1A130A
AutoCAD SHX Text B1B103A
AutoCAD SHX Text B1B109A
AutoCAD SHX Text B1B101A
AutoCAD SHX Text B1A129A
AutoCAD SHX Text B1A123A
AutoCAD SHX Text B1A117A
AutoCAD SHX Text B1B114A
AutoCAD SHX Text B1B119A
AutoCAD SHX Text B1B127A
AutoCAD SHX Text B1B117A
AutoCAD SHX Text B1B124A
AutoCAD SHX Text B1B132A
AutoCAD SHX Text B1B131A
AutoCAD SHX Text B1B123A
AutoCAD SHX Text B1B120A
AutoCAD SHX Text B1B128A
AutoCAD SHX Text B1A149A
AutoCAD SHX Text B1A146A
AutoCAD SHX Text B1A139A
AutoCAD SHX Text B1A137A
AutoCAD SHX Text B1B110A
AutoCAD SHX Text B1B108A
AutoCAD SHX Text B1B102A
AutoCAD SHX Text B1A132A
AutoCAD SHX Text B1B150A
AutoCAD SHX Text B1B149A
AutoCAD SHX Text B1B145A
AutoCAD SHX Text B1B144A
AutoCAD SHX Text B1B139A
AutoCAD SHX Text
UP 25R
AutoCAD SHX Text
UP 25R
AutoCAD SHX Text B1A155A
AutoCAD SHX Text B1A166-2
AutoCAD SHX Text B1B136A
AutoCAD SHX Text B1C6-1
AutoCAD SHX Text
BEL1
AutoCAD SHX Text
BEL2
AutoCAD SHX Text B1B141
AutoCAD SHX Text 1B1A102
AutoCAD SHX Text 1B1A101
AutoCAD SHX Text 1B1C1
AutoCAD SHX Text 1B1A142
AutoCAD SHX Text 1B1A136
AutoCAD SHX Text B1C9
AutoCAD SHX Text B1C7
AutoCAD SHX Text B1C5
AutoCAD SHX Text 1B1C4
AutoCAD SHX Text B1C2
AutoCAD SHX Text
DINING HALL
AutoCAD SHX Text 1B152
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1B117
AutoCAD SHX Text 1B116
AutoCAD SHX Text
AutoCAD SHX Text
OPEN
AutoCAD SHX Text 1B120
AutoCAD SHX Text 1B119
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 1B126
AutoCAD SHX Text 1B128
AutoCAD SHX Text 1B129
AutoCAD SHX Text 1B130
AutoCAD SHX Text 1B118
AutoCAD SHX Text 1B115
AutoCAD SHX Text 1B114
AutoCAD SHX Text 1B111
AutoCAD SHX Text 1B113
AutoCAD SHX Text 1B112
AutoCAD SHX Text 1B108
AutoCAD SHX Text 1B104
AutoCAD SHX Text 1B105
AutoCAD SHX Text 1B103
AutoCAD SHX Text 1B102
AutoCAD SHX Text 1B100
AutoCAD SHX Text 1B101
AutoCAD SHX Text 1A122
AutoCAD SHX Text 1A123
AutoCAD SHX Text 1A121
AutoCAD SHX Text 1A120
AutoCAD SHX Text 1A117
AutoCAD SHX Text 1A114
AutoCAD SHX Text 1A113
AutoCAD SHX Text 1A115
AutoCAD SHX Text 1A116
AutoCAD SHX Text 1A106
AutoCAD SHX Text
AutoCAD SHX Text 1A128
AutoCAD SHX Text 1A133
AutoCAD SHX Text 1A134
AutoCAD SHX Text 1A138
AutoCAD SHX Text A139
AutoCAD SHX Text A140
AutoCAD SHX Text 1A141
AutoCAD SHX Text 1A142
AutoCAD SHX Text 1A143
AutoCAD SHX Text 1A145
AutoCAD SHX Text 1A146
AutoCAD SHX Text 1A148
AutoCAD SHX Text 1A149
AutoCAD SHX Text 1A150
AutoCAD SHX Text 1A151
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
WORKOUT
AutoCAD SHX Text
OIT
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
OIT
AutoCAD SHX Text 1A119
AutoCAD SHX Text 1A125
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text B110
AutoCAD SHX Text
HAC
AutoCAD SHX Text
WOMENS
AutoCAD SHX Text
MENS
AutoCAD SHX Text 1A137
AutoCAD SHX Text 1A136
AutoCAD SHX Text 1A137
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
FEMALE
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
MALE
AutoCAD SHX Text
HALL
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
RISER ROOM
AutoCAD SHX Text
ADMINISTRATION
AutoCAD SHX Text 2,210 Sq. Ft.
AutoCAD SHX Text
AutoCAD SHX Text
NON PATIENT CARE
AutoCAD SHX Text
SUITE
ZONE 2BZONE 2A
ZONE 2BZONE 2A
F
FAED
A E
D
EW
EW
SECOND FLOOR
BUSINESS OCCUPANCY
FULLY SPRINKLERED
BUILDING 113
N
SECOND FLOOR
BUILDING 113
23400
DATEREVISIONS: NUMBER
DRAFT SOC 4/08/2024
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
KC LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C CONSULTANTS,
JLB DJB
HINES, ILLINOIS
EDWARD HINES, JR. VA
STATEMENT OF CONDITIONS
DOCUMENTATIONEdward Hines, Jr.
VA Hospital 5000 5th Ave
Hines, IL 60141 Checked by Drawn by
Dwg. of 64
113SOC-2
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
578-24-002
APPROVED SITE EQUIVALENCIES
BUILDING 200 - MAIN HOSPITAL
1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.
2. STAIR NO. 1 EXIT PASSAGEWAY.
BUILDING 221 - REHABILITATION CENTER
1. MODULAR BUILDING CONSTRUCTION SEPARATION.
FINAL SOC
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
06/19/2024
6/19/2024
AutoCAD SHX Text
O+M SUPER.
AutoCAD SHX Text
M.S. WOOD/ LEATHER SHOP
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
LEATHER WEAVING & CERAMICS
AutoCAD SHX Text
M.S.HOME MECH
AutoCAD SHX Text
M.S. ASSESS
AutoCAD SHX Text
KILN
AutoCAD SHX Text
PREP. RM.
AutoCAD SHX Text
OIT
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
FINISH RM.
AutoCAD SHX Text
CONTINUE ED. RESOURCE RM.
AutoCAD SHX Text
ELEV.#2
AutoCAD SHX Text
MECH. SHAFT
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
TRAINING KITCHEN
AutoCAD SHX Text
LS CLASSROOM
AutoCAD SHX Text
CAT EQUIP.
AutoCAD SHX Text
LS CLASSROOM
AutoCAD SHX Text
LS CLASSROOM
AutoCAD SHX Text
MECH. CHASE
AutoCAD SHX Text
CAT 1
AutoCAD SHX Text
CAT 2
AutoCAD SHX Text
CAT 4
AutoCAD SHX Text
CAT 3
AutoCAD SHX Text
CAT 5
AutoCAD SHX Text
CAT 6
AutoCAD SHX Text
CAT ASSESS
AutoCAD SHX Text
CAT SUPER
AutoCAD SHX Text
OPT RESEARCH
AutoCAD SHX Text
OPT EXAM
AutoCAD SHX Text
HUMPHREY
AutoCAD SHX Text
EYE LANE
AutoCAD SHX Text
EYE LANE
AutoCAD SHX Text
VS-1
AutoCAD SHX Text
CCTV CLASSROOM
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
WAIT.
AutoCAD SHX Text
CAT SPECIALIST
AutoCAD SHX Text
CAT SPECIALIST
AutoCAD SHX Text
EVALUATION
AutoCAD SHX Text
O+M STORAGE
AutoCAD SHX Text
LS CLASSROOM
AutoCAD SHX Text
LS SPECIALIST OFFICES
AutoCAD SHX Text
STAFF LOCKERS
AutoCAD SHX Text
LS FAMILY TRAINING
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
LS FAMILY TRAINING
AutoCAD SHX Text
LS CLASSRM.
AutoCAD SHX Text
O+M SPEC.
AutoCAD SHX Text
O+M COORD.
AutoCAD SHX Text
LS SUPER.
AutoCAD SHX Text
TRAINING KITCHEN
AutoCAD SHX Text
TRAINING KITCHEN
AutoCAD SHX Text
LS CLASSRM. / DINING RM.
AutoCAD SHX Text
O+M SPECIALIST
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
ELEV.#1
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
OIT
AutoCAD SHX Text
HAC
AutoCAD SHX Text
LS STORAGE
AutoCAD SHX Text
VS-2
AutoCAD SHX Text
VS-3
AutoCAD SHX Text
VS-4
AutoCAD SHX Text
VS-6
AutoCAD SHX Text
VS-5
AutoCAD SHX Text
VS SPECIALIST
AutoCAD SHX Text
VS SUPERVISOR
AutoCAD SHX Text
OPTION OFFICE
AutoCAD SHX Text
OPTION RESIDENT & STUDENT
AutoCAD SHX Text
ECCENTRIC TRAINING
AutoCAD SHX Text
VS-6
AutoCAD SHX Text
MS STAFF
AutoCAD SHX Text
VS STORAGE
AutoCAD SHX Text
MS SUPER. OFFICE
AutoCAD SHX Text
SMALL ENGINE REPAIR
AutoCAD SHX Text
HAC
AutoCAD SHX Text B2A215
AutoCAD SHX Text B2A118
AutoCAD SHX Text B2A117
AutoCAD SHX Text B2A119
AutoCAD SHX Text B2A120
AutoCAD SHX Text B2A121
AutoCAD SHX Text B2A123
AutoCAD SHX Text B2A125
AutoCAD SHX Text B2A126
AutoCAD SHX Text B2A128
AutoCAD SHX Text B2A129
AutoCAD SHX Text B2B100
AutoCAD SHX Text B2B102
AutoCAD SHX Text B2B104
AutoCAD SHX Text B2B105
AutoCAD SHX Text B207
AutoCAD SHX Text B2B109
AutoCAD SHX Text B2B111
AutoCAD SHX Text B213
AutoCAD SHX Text
B2ST2
AutoCAD SHX Text B215
AutoCAD SHX Text B2C5
AutoCAD SHX Text B2A114
AutoCAD SHX Text A213
AutoCAD SHX Text B2A114A
AutoCAD SHX Text A222
AutoCAD SHX Text B2A124
AutoCAD SHX Text B2A127
AutoCAD SHX Text B2A130
AutoCAD SHX Text 2A230
AutoCAD SHX Text B201
AutoCAD SHX Text B2B103
AutoCAD SHX Text B2B106
AutoCAD SHX Text B208
AutoCAD SHX Text B2B110
AutoCAD SHX Text B2B112
AutoCAD SHX Text B2B114
AutoCAD SHX Text B216
AutoCAD SHX Text B2B117-1
AutoCAD SHX Text B2B117-2
AutoCAD SHX Text B219
AutoCAD SHX Text B2B121-2
AutoCAD SHX Text B2B121-1
AutoCAD SHX Text B225
AutoCAD SHX Text B2B126
AutoCAD SHX Text B2B127-2
AutoCAD SHX Text B227
AutoCAD SHX Text B229
AutoCAD SHX Text B2B130
AutoCAD SHX Text B2B131
AutoCAD SHX Text B2C6
AutoCAD SHX Text B228
AutoCAD SHX Text B224
AutoCAD SHX Text B2B122
AutoCAD SHX Text B2B123
AutoCAD SHX Text B2B120
AutoCAD SHX Text B2B118
AutoCAD SHX Text B233
AutoCAD SHX Text B2B235
AutoCAD SHX Text B236
AutoCAD SHX Text B2B136-2
AutoCAD SHX Text B2B134-1
AutoCAD SHX Text B2B134-2
AutoCAD SHX Text B2B132
AutoCAD SHX Text B2B139
AutoCAD SHX Text B2B140
AutoCAD SHX Text B2C7
AutoCAD SHX Text B2B138
AutoCAD SHX Text B2B137
AutoCAD SHX Text B2A100
AutoCAD SHX Text B2A235
AutoCAD SHX Text B2A234
AutoCAD SHX Text 2A234
AutoCAD SHX Text A233
AutoCAD SHX Text B2A131
AutoCAD SHX Text B2A133
AutoCAD SHX Text A206A
AutoCAD SHX Text A211
AutoCAD SHX Text B2A112
AutoCAD SHX Text B2A106-1
AutoCAD SHX Text A206
AutoCAD SHX Text B2A102
AutoCAD SHX Text A201
AutoCAD SHX Text B2A109
AutoCAD SHX Text B2A110
AutoCAD SHX Text B2A108
AutoCAD SHX Text B2A107
AutoCAD SHX Text A205
AutoCAD SHX Text B2A105-2
AutoCAD SHX Text B2A105-3
AutoCAD SHX Text B2A204
AutoCAD SHX Text A203
AutoCAD SHX Text B2A117A
AutoCAD SHX Text
B2ST1
AutoCAD SHX Text
DN 25R
AutoCAD SHX Text
DN 25R
AutoCAD SHX Text
UP 25R
AutoCAD SHX Text
BUILDING 228
AutoCAD SHX Text
OPEN TO BELOW
AutoCAD SHX Text
LINK ROOF
AutoCAD SHX Text
CANOPY BELOW
AutoCAD SHX Text B2C1
AutoCAD SHX Text
BEL1
AutoCAD SHX Text
BEL2
AutoCAD SHX Text B2C2
AutoCAD SHX Text B2C4
AutoCAD SHX Text 2B2C7
AutoCAD SHX Text B2C6
AutoCAD SHX Text B2C5
AutoCAD SHX Text B2B133A
AutoCAD SHX Text B2C3
AutoCAD SHX Text 2A233A
AutoCAD SHX Text 2B230
AutoCAD SHX Text 2B231
AutoCAD SHX Text 2B229
AutoCAD SHX Text 2B227
AutoCAD SHX Text 2B226
AutoCAD SHX Text 2B225
AutoCAD SHX Text 2B222
AutoCAD SHX Text 2B223
AutoCAD SHX Text 2B224
AutoCAD SHX Text 2B221
AutoCAD SHX Text 2B220
AutoCAD SHX Text 2B219
AutoCAD SHX Text 2B217
AutoCAD SHX Text B216
AutoCAD SHX Text B215
AutoCAD SHX Text 2B211
AutoCAD SHX Text 2B210
AutoCAD SHX Text 2A207
AutoCAD SHX Text 2A206
AutoCAD SHX Text 2A203
AutoCAD SHX Text 2A202
AutoCAD SHX Text 2A200
AutoCAD SHX Text 2A229
AutoCAD SHX Text 2A228
AutoCAD SHX Text 2A227
AutoCAD SHX Text 2A225
AutoCAD SHX Text 2A221
AutoCAD SHX Text 2A220
AutoCAD SHX Text 2A219
AutoCAD SHX Text 2A218
AutoCAD SHX Text 2A215
AutoCAD SHX Text 2A123
AutoCAD SHX Text 2A231
AutoCAD SHX Text 2A201
AutoCAD SHX Text 2A204
AutoCAD SHX Text 2A205
AutoCAD SHX Text 2B208
AutoCAD SHX Text 2B209
AutoCAD SHX Text 2B214
AutoCAD SHX Text 2B218
AutoCAD SHX Text 2A203
AutoCAD SHX Text 2A204
AutoCAD SHX Text 2A205
AutoCAD SHX Text 2A207
AutoCAD SHX Text 2B236B
AutoCAD SHX Text 2B236A
AutoCAD SHX Text 2A235
AutoCAD SHX Text 2B234
AutoCAD SHX Text 2B232
AutoCAD SHX Text 2B233
AutoCAD SHX Text 2B235
AutoCAD SHX Text 2B236
AutoCAD SHX Text 2A200
AutoCAD SHX Text
MENS
AutoCAD SHX Text 2A202
AutoCAD SHX Text
WOMENS
AutoCAD SHX Text 2A201
AutoCAD SHX Text 2A211
AutoCAD SHX Text 2A212
AutoCAD SHX Text A232
AutoCAD SHX Text 2A223
AutoCAD SHX Text 2A124
AutoCAD SHX Text
F
PENTHOUSE FLOOR
INDUSTRIAL OCCUPANCY
FULLY SPRINKLERED
BUILDING 113
THIRD FLOOR
BUILDING 113
N
23400
DATEREVISIONS: NUMBER
DRAFT SOC 4/08/2024
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
KC LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C CONSULTANTS,
JLB DJB
HINES, ILLINOIS
EDWARD HINES, JR. VA
STATEMENT OF CONDITIONS
DOCUMENTATIONEdward Hines, Jr.
VA Hospital 5000 5th Ave
Hines, IL 60141 Checked by Drawn by
Dwg. of 64
113SOC-PH
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
578-24-002
APPROVED SITE EQUIVALENCIES
BUILDING 200 - MAIN HOSPITAL
1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.
2. STAIR NO. 1 EXIT PASSAGEWAY.
BUILDING 221 - REHABILITATION CENTER
1. MODULAR BUILDING CONSTRUCTION SEPARATION.
FINAL SOC
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
06/19/2024
6/19/2024
AutoCAD SHX Text
B3ST1
AutoCAD SHX Text B3A101
AutoCAD SHX Text B3A102
AutoCAD SHX Text
DN 25R
AutoCAD SHX Text B3A100-1
AutoCAD SHX Text B3A100-2
AutoCAD SHX Text
OPEN TO BELOW
AutoCAD SHX Text
MECHANICAL EQUIPMENT
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
AutoCAD SHX Text
ELEV 1 EQUIP.
ELEV 2 EQUIP.
HE
BASEMENT
BUSINESS OCCUPANCY
FULLY SPRINKLERED
BUILDING 128
BASEMENT
BUILDING 128
N
23400
DATEREVISIONS: NUMBER
DRAFT SOC 4/08/2024
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
KC LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C CONSULTANTS,
JLB DJB
HINES, ILLINOIS
EDWARD HINES, JR. VA
STATEMENT OF CONDITIONS
DOCUMENTATIONEdward Hines, Jr.
VA Hospital 5000 5th Ave
Hines, IL 60141 Checked by Drawn by
Dwg. of 64
128SOC-B
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
578-24-002
APPROVED SITE EQUIVALENCIES
BUILDING 200 - MAIN HOSPITAL
1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.
2. STAIR NO. 1 EXIT PASSAGEWAY.
BUILDING 221 - REHABILITATION CENTER
1. MODULAR BUILDING CONSTRUCTION SEPARATION.
FINAL SOC
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
06/19/2024
6/19/2024
AutoCAD SHX Text
SBA100
AutoCAD SHX Text
SBA101
AutoCAD SHX Text
SBST1
AutoCAD SHX Text
SBA104
AutoCAD SHX Text
SBA103
AutoCAD SHX Text
UP 24R
AutoCAD SHX Text
SBA102
AutoCAD SHX Text
SBA106
AutoCAD SHX Text
SBA105
AutoCAD SHX Text
SBA107
AutoCAD SHX Text
UNASSIGNED
AutoCAD SHX Text
PATIENT STORAGE
AutoCAD SHX Text
HEALTH CARE TECHNOLOGY MANAGEMENT
AutoCAD SHX Text
ELEVATOR MACHINE RM.
AutoCAD SHX Text
TELE COM
AutoCAD SHX Text
ELEV. #1
AutoCAD SHX Text
ELEV. #2
AutoCAD SHX Text
SEL1
AutoCAD SHX Text
SEL2
AutoCAD SHX Text
SBC1
AutoCAD SHX Text
SBC2
AutoCAD SHX Text
TO BUILDING 200
AutoCAD SHX Text S003
AutoCAD SHX Text S002
AutoCAD SHX Text S001
AutoCAD SHX Text S004
EX
EXEX
EX
NORTH WARD SOUTH WARD
EXCENTER WARD
2 BUILDING 128 BUILDING 200
F
F
F A
A P
F
F
F
F A
C P
F
F
CENTER WARD
F
F
F
F
BUILDING 128
PENTHOUSE
FIRST FLOOR
HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
SUITE DESCRIPTIONS
KEY NOTES:
BUILDING 128
N
FIRST FLOOR
BUILDING 128
23400
DATEREVISIONS: NUMBER
DRAFT SOC 4/08/2024
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
KC LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C CONSULTANTS,
JLB DJB
HINES, ILLINOIS
EDWARD HINES, JR. VA
STATEMENT OF CONDITIONS
DOCUMENTATIONEdward Hines, Jr.
VA Hospital 5000 5th Ave
Hines, IL 60141 Checked by Drawn by
Dwg. of 64
128SOC-1
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
578-24-002
APPROVED SITE EQUIVALENCIES
BUILDING 200 - MAIN HOSPITAL
1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.
2. STAIR NO. 1 EXIT PASSAGEWAY.
BUILDING 221 - REHABILITATION CENTER
1. MODULAR BUILDING CONSTRUCTION SEPARATION.
FINAL SOC
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
06/19/2024
6/19/2024
SMOKE ZONE SQ. FT. OCCUPANCY
SMOKE ZONE SIZE
AutoCAD SHX Text
UP 28R
AutoCAD SHX Text
UP 28R
AutoCAD SHX Text C1-1A
AutoCAD SHX Text P.N4
AutoCAD SHX Text C1-1A
AutoCAD SHX Text
TUNNEL BELOW
AutoCAD SHX Text
SEMI S.4
AutoCAD SHX Text
SEMI N.4
AutoCAD SHX Text
SEMI S.9
AutoCAD SHX Text
SEMI S.8
AutoCAD SHX Text
SEMI S.7
AutoCAD SHX Text
SEMI N.3
AutoCAD SHX Text
SEMI N.2
AutoCAD SHX Text
SEMI S.2
AutoCAD SHX Text
SEMI S.3
AutoCAD SHX Text
MED. EQUIP.
AutoCAD SHX Text
NURSE STATION
AutoCAD SHX Text
CLEAN LINEN
AutoCAD SHX Text
SOILED UTILITY
AutoCAD SHX Text P.N5
AutoCAD SHX Text P.N6
AutoCAD SHX Text P.N4
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
HAC
AutoCAD SHX Text
SOILED LINEN
AutoCAD SHX Text
HEAD NURSE
AutoCAD SHX Text
DOCTOR
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
TEL ROOM
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
TEL.
AutoCAD SHX Text
ELEV.#1
AutoCAD SHX Text
ELEV.#2
AutoCAD SHX Text
EXAM 5
AutoCAD SHX Text
EXAM 1
AutoCAD SHX Text
EXAM 4
AutoCAD SHX Text
EXAM 2
AutoCAD SHX Text
EXAM 3
AutoCAD SHX Text
SOILED LINEN
AutoCAD SHX Text
NURSE
AutoCAD SHX Text
SCHED.
AutoCAD SHX Text
INTERVIEW
AutoCAD SHX Text
TRAINING
AutoCAD SHX Text
NURSE OFFICE
AutoCAD SHX Text
ADL TOILET
AutoCAD SHX Text
SOCIAL WORK
AutoCAD SHX Text
PATIENT WAITING
AutoCAD SHX Text
DRESS
AutoCAD SHX Text
CLEAN
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text P.N1
AutoCAD SHX Text P.N3
AutoCAD SHX Text P.N2
AutoCAD SHX Text
RESIDENT
AutoCAD SHX Text
STAFF TOILET
AutoCAD SHX Text
COURTYARD
AutoCAD SHX Text
SEMI. S.1
AutoCAD SHX Text
REPORT
AutoCAD SHX Text
MEDICATIONS
AutoCAD SHX Text
NOURISH
AutoCAD SHX Text
CLEAN UTILITY
AutoCAD SHX Text
NURSE OFFICE
AutoCAD SHX Text
COORD. OFFICE
AutoCAD SHX Text
SEC.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
NURSE OFFICE
AutoCAD SHX Text
NURSE OFFICE
AutoCAD SHX Text
PUBLIC WAIT.
AutoCAD SHX Text
SEC.
AutoCAD SHX Text
SEC.
AutoCAD SHX Text
CHIEF
AutoCAD SHX Text
EDUC. THERAPY
AutoCAD SHX Text
TEL.
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
PRIVATE FAMILY WAITING
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
SEMI S.5
AutoCAD SHX Text
ISO S.1
AutoCAD SHX Text
SEMI N9
AutoCAD SHX Text
SEMI N.8
AutoCAD SHX Text
ISO N.1
AutoCAD SHX Text
ISO N2
AutoCAD SHX Text
SEMI N5
AutoCAD SHX Text
SEMI N6
AutoCAD SHX Text
SEMI N7
AutoCAD SHX Text
BREAK
AutoCAD SHX Text
SEMI N.4
AutoCAD SHX Text
SEMI
AutoCAD SHX Text
SEMI N.2
AutoCAD SHX Text
SEMI N.1
AutoCAD SHX Text
NURSE STATION NORTH
AutoCAD SHX Text
MAJOR MED. EQUIP.
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
SEMI S.10
AutoCAD SHX Text
SEMI
AutoCAD SHX Text
SEMI S13
AutoCAD SHX Text
SEMI S12
AutoCAD SHX Text
MED. EQUIP.
AutoCAD SHX Text
MEDICATION
AutoCAD SHX Text
CLEAN LINEN
AutoCAD SHX Text
SOILED UTILITY
AutoCAD SHX Text
SOILED LINEN
AutoCAD SHX Text
PT EQUIP.
AutoCAD SHX Text
CLEAN UTILITY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text P.N1
AutoCAD SHX Text
PVA COUNSELOR
AutoCAD SHX Text P.N2
AutoCAD SHX Text P.N3
AutoCAD SHX Text
DOCTOR
AutoCAD SHX Text
SOCIAL WORKER
AutoCAD SHX Text P.N5
AutoCAD SHX Text P.N6
AutoCAD SHX Text
STAFF LOCKER RM.
AutoCAD SHX Text
DOCTOR OFFICE
AutoCAD SHX Text
DOCTOR OFFICE
AutoCAD SHX Text
DOCTOR OFFICE
AutoCAD SHX Text
DOCTOR OFFICE
AutoCAD SHX Text
DOCTOR OFFICE
AutoCAD SHX Text
PSYCH OFFICE
AutoCAD SHX Text
PSYCH OFFICE
AutoCAD SHX Text
INTERVIEW
AutoCAD SHX Text
S.C.I HOME CARE
AutoCAD SHX Text
HEALTH TECH OFFICE
AutoCAD SHX Text
TEL.
AutoCAD SHX Text
SOC. WK. OFFICE
AutoCAD SHX Text
CONF.
AutoCAD SHX Text
ADMIN. OFFICE
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
DINING
AutoCAD SHX Text
HEAD NURSE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
HAC
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
QUIET TREATMENT
AutoCAD SHX Text
ADL
AutoCAD SHX Text
MECH -FIRE
AutoCAD SHX Text
PT/KT
AutoCAD SHX Text
SUB-WAITING
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
SEMI N.1
AutoCAD SHX Text
SPECIAL CARE NURSE STATION
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
ISO S.2
AutoCAD SHX Text
ISO S.6
AutoCAD SHX Text
NC
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
NC
AutoCAD SHX Text
DN
AutoCAD SHX Text 1A108
AutoCAD SHX Text 1A109
AutoCAD SHX Text 1A111
AutoCAD SHX Text 1A113
AutoCAD SHX Text 1A115
AutoCAD SHX Text 1A117
AutoCAD SHX Text 1A120
AutoCAD SHX Text 1A110
AutoCAD SHX Text 1A112
AutoCAD SHX Text 1A114
AutoCAD SHX Text 1A116
AutoCAD SHX Text 1A121
AutoCAD SHX Text 1A100D
AutoCAD SHX Text 1A100E
AutoCAD SHX Text 1A122
AutoCAD SHX Text 1A123
AutoCAD SHX Text 1A124
AutoCAD SHX Text 1A100B
AutoCAD SHX Text 1A100
AutoCAD SHX Text 1A100C
AutoCAD SHX Text 1C147
AutoCAD SHX Text 1C145
AutoCAD SHX Text 1C142
AutoCAD SHX Text 1C138
AutoCAD SHX Text 1C146
AutoCAD SHX Text 1C144
AutoCAD SHX Text 1C100
AutoCAD SHX Text 1C102
AutoCAD SHX Text 1C103
AutoCAD SHX Text 1C105
AutoCAD SHX Text 1C143
AutoCAD SHX Text 1C141
AutoCAD SHX Text 1C140
AutoCAD SHX Text 1C107
AutoCAD SHX Text 1C101
AutoCAD SHX Text 1C104
AutoCAD SHX Text 1C106
AutoCAD SHX Text 1A148A
AutoCAD SHX Text 1A148
AutoCAD SHX Text A149
AutoCAD SHX Text 1A134
AutoCAD SHX Text 1A135
AutoCAD SHX Text 1A127
AutoCAD SHX Text 1A128
AutoCAD SHX Text 1A131
AutoCAD SHX Text 1A133
AutoCAD SHX Text 1A133B
AutoCAD SHX Text 1A129
AutoCAD SHX Text 1A130
AutoCAD SHX Text 1A132
AutoCAD SHX Text 1A133A
AutoCAD SHX Text 1A137
AutoCAD SHX Text 1A139
AutoCAD SHX Text 1A142
AutoCAD SHX Text 1A143
AutoCAD SHX Text 1A138
AutoCAD SHX Text 1A140
AutoCAD SHX Text 1A141
AutoCAD SHX Text 1A144
AutoCAD SHX Text 1A145
AutoCAD SHX…
This is the start of the file's text. The full file is on GovTribe.