S06 001.Att4a S02_Att17a DWGS_Healthcare Bldgs 113_128_200_217_221_228.pdf

PDF 20 MB Posted

Attached to
Z1DA--578-26-004: IDIQ ACM Abatement Base
Solicitation number
36C25226B0020
Issued by

About this file

This is a Statement of Conditions (SOC) documentation package for the Edward Hines, Jr. VA Hospital in Hines, Illinois, detailing fire and life safety conditions across multiple buildings and floors. The document serves as a comprehensive record of building occupancies, fire protection systems, smoke compartmentalization, and emergency egress requirements in compliance with the 2024 NFPA 101 Life Safety Code and 2022 NFPA 80 standards.

The facility encompasses six primary buildings (113, 128, 200, 217, 221, and 228) with varying occupancy classifications including health care, ambulatory care, business, industrial, and storage uses across basement through seventeenth floors. Key fire protection features include fully sprinklered systems utilizing quick response and standard response sprinklers per NFPA 13 and 14, with quick response types predominating in patient care areas at 0.10 GPM/1500 sq. ft. density. Fire barrier classifications include 2-hour fire and smoke zone barriers for occupancy separations and stairwells of four or more stories, 1-hour fire barriers for hazardous room enclosures and stairwells of three stories or less, and non-rated smoke barriers for compartmentalization. Fire alarm systems comply with 2019 NFPA 72 standards and include private mode audible and visible notification devices. The facility maintains approved equivalencies from The Joint Commission including oversized protective plates on fire-rated doors, extended business occupancy dead-end corridors beyond 50 feet, and modular building construction separation in Building 221. All drawings include detailed partition legends, suite designations, smoke zone boundaries, and fire alarm/sprinkler zone demarcations. Total documented occupancy across all measured spaces is 1,454,624 square feet.

View the file

Other files

File Type Posted
S06 Att1_S02 Insert B.2 IDIQ Abatement Services PRICE SCHEDULE-Rev1.docx DOCX document
36C25226B0020 0004.docx DOCX document
S06 Att12.rev DB Wages_COOK CTY_rev2 IL20260009 2026.05.18 current_2026.06.17.pdf PDF
36C25226B0020 0003.docx DOCX document
S06 0002 Att1.pdf PDF
36C25226B0020 0002.docx DOCX document
S06 001.Att6 Site Visit Sign In Sheets 2026.04.13_04.20.pdf PDF
S06 001.Att5 S02_Att18 Reference_2022 Facility Condition Assessment Report_rev.pdf PDF
S06 001.Att0.0 S02_Att00 SOW.R1 2026.04.23 578-26-004 Base IDIQ Abatement Services.pdf PDF
36C25226B0020 0001.docx DOCX document
S06 001.Att1 S02_Att14 VHA Directive 7714_D_2017-04-06 Asbestos Mangement Plan.pdf PDF
S06 001.Att0.1 S02_Att7.0 Seed SOW.Rev1 Project 578-26-008 TO-E Abatement Bldgs 1_200 2026.04.22 (1).pdf PDF
S06 001.Att4b S02_Att17b DWGS_Outer Bldgs_01_12, and 13.pdf PDF
S06 001.Att3 S02_Att16 Hines VA Preservation Plan with Inventory_updated 2013.pdf PDF
Copy of S06 001.Att2 S02_Att15 Asbestos Survey for EHVAH.xlsx XLSX spreadsheet
S02 Att07.2 Seed 578-26-008 SPECS.pdf PDF
S02 Att07.5 Seed 578-26-008 ILSM.pdf PDF
S02 Att07.3 Seed 578-26-008 VHA PCRA-1-1.pdf PDF
36C25226B0020_4.docx DOCX document
S02 Att03 Emergency Contact List - Template.pdf PDF
S02 Att12 DB Wage Rates_COOK CTY_rev1 IL20260009 2026.01.09 current as of 2026.04.07.pdf PDF
S02 Att07.6 Seed 578-26-008 Hines Abatement TO-E Locations.pdf PDF
S02 Att04 Contractor Badging - Fingerprint Request Form 2025.pdf PDF
S02 Att09 Contractor Surety Limitations 578-26-004_B0020.pdf PDF
S02 Att08 Financial Disclosure Questionnaire IDIQ Abatement B0020.pdf PDF
S02 Att13 SOL 0020 VAAR 852.219-75 Certification 578-26-004.docx DOCX document
S02 Att07.1 Seed SOW 578-26-008 Hines Documents for Construction with TOC.pdf PDF
S02 Att00 SOW 578-26-004 IDIQ Abatement Services.pdf PDF
S02 Att11 Contractor General Information 578-26-004_B0020.pdf PDF
S02 Att01 Unit Pricing 2025.08.28 578-26-008 TO-E Abmt Bldgs 1_200.xlsx XLSX spreadsheet
S02 Att07.0 Seed SOW 578-26-008 Abatement TO-E Bldgs 1_200 2025.08.28.pdf PDF
S02 Att10 Contractor Safety and EMR 578-26-004_B0020.pdf PDF
S02 Att02 HINES VA SITE PLAN 5-1-2025.pdf PDF
S02 Att07.4 Seed 578-26-008 VHA ICRA-1-3.pdf PDF
S02 Att05 VHA PCRA-1.1_May 21 2024.pdf PDF
S02 Att06 VHA ICRA-1.3_Dec 9 2024.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EW

FAAP

FACP

FIRE EXTINGUISHER

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM STATION

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

AUTOMATED EXTERNAL DEFIBRILLATOR

F

AED

EYEWASH STATION

SPRINKLER SYSTEM RISER

SH SHOWER STATION

SIAMESE (FIRE DEPARTMENT CONNECTION)

FIRE HOSE VALVEFHV

SYMBOLS LIST

WALL:

DUCTS:

PENETRATIONS:

DOORS:

WALL:

DUCTS:

DOORS:

WALL:

DUCTS:

PENETRATIONS:

DOORS:

SUITE DESIGNATION

2-HOUR FIRE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF

4 OR MORE STORIES.

2-HOUR FIRE AND SMOKE ZONE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND

STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION

OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.

1-HOUR FIRE BARRIER

THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPARATIONS, HAZARDOUS ROOM

ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.

SMOKE ZONE BARRIER

SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR

DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS

OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND

THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE

REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.7.6) SMOKE

ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED

TO BE OF A 1/2 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)

(COLOR #5)

(COLOR #4)

(COLOR #1)

(COLOR #2)

(COLOR #3)

NOTE: ALL CODE REFERENCES ARE PER THE 2024 EDITION OF NFPA 101 LIFE SAFETY CODE AND 2022 EDITION OF NFPA 80. FEDERAL FACILITIES FOLLOW 2024 LIFE SAFETY CODE.

DOORS: 1. NON-LABELED FRAME PERMITTED IF AREA IS SPRINKLERED (NFPA 101 18.3.6.3.1 & 19.3.6.3.15)

2. NON-RATED DOORS PERMITTED IF AREA IS SPRINKLERED (NFPA 101

18.3.6.3.1, 19.3.6.3.2(2))

3. 20-MINUTE OR 1-3/4" SOLID WOOD CORE IF AREA IS NOT SPRINKLERED (NFPA 101 19.3.6.3.1)

4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER, SINK, AND SIMILAR ROOMS (NFPA 101 18.3.6.3.6 &

19.3.6.3.11)

5. SELF-CLOSING NOT REQUIRED (NFPA 101 18.3.6.3.12 & 19.3.6.3.11)

6. MAXIMUM 1/8" GAP (JOINT COMMISION)

7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)

8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.6.3.13 & 19.3.6.3.12)

9. TRANSFER GRILLES NOT PERMITTED EXCEPT TOILETS, SHOWER, SINK, AND SIMILAR ROOMS

(NFPA 101 18/19.3.6.4)

10. SWING IN ANY DIRECTION IF FEWER THAN 50 OCCUPANTS (NFPA 101 7.2.1.4.2)

(COLOR #30)

NON-RATED SMOKE ZONE PARTITION

DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER ZONE.

BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY THE FIRE

DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99 AND PRIVATE MODE AUDIBLE

REQUIREMENTS OF SECTION 18.4.5 OF NFPA 72.

WALL:

DUCTS:

PENETRATIONS:

DOORS:

HEALTH CARE OCCUPANCY CORRIDORS

IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED

TO LIMIT TRANSFER OF SMOKE.

IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALLS SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. EXISTING CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 18/19.3.6.2

PENETRATIONS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO BE

FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO

BE FILLED ON THE TOP OF THE FLOOR.

1. LABELED FRAMES (NFPA 101 8.3.3.3.2)

2. LABELED 1 1/2 HOUR DOOR (NFPA 101 TABLE 8.3.3.2.2)

3. VISION PANEL PERMITTED* UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE 8.3.3.2.2).

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED IF ASTRAGALS ARE PRESENT** (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" HIGH PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)

10. SWING IN DIRECTION OF EGRESS (NFPA 101 7.2.1.4.2).

11. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 80 5.2.4.1)

* VISION PANELS REQUIRED FOR DOORS IN NEW HORIZONTAL EXITS (NFPA 101 18.2.2.5.6)

** IN DOOR PAIRS, ASTRAGALS NOT PERMITTED TO INHIBIT FREE USE OF EITHER LEAF

(NFPA 80 6.4.7.1)

WALL:

DUCTS:

PENETRATIONS:

DOORS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND SMOKE

DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE

COMPARTMENTS ARE PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT

EACH COMPARTMENT.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO BE

FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO

BE FILLED ON THE TOP OF THE FLOOR.

1. LABELED FRAMES (NFPA 101 8.3.3.3.2)

2. LABELED 1 1/2 HOUR DOOR (NFPA 101 TABLE 8.3.3.2.2)

3. VISION PANEL PERMITTED* UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE 8.3.3.2.2)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED IF ASTRAGALS ARE PRESENT** (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" HIGH PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5.1)

10.SWING IN DIRECTION OF EGRESS (NFPA 101 7.2.1.4.2).

11. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 80 5.2.4.1)

* VISION PANELS REQUIRED FOR DOORS IN NEW HORIZONTAL EXITS (NFPA 101 18.2.2.5.6)

** IN DOOR PAIRS, ASTRAGALS NOT PERMITTED TO INHIBIT FREE USE OF EITHER LEAF

(NFPA 80 6.4.7.1)

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED

TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY

REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.

1. LABELED FRAMES (NFPA 101 8.3.3.3.2)

2. LABELED 3/4 OR 1-HOUR* DOOR (NFPA 101 TABLE 8.3.3.2.2)

3. VISION PANEL PERMITTED UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE

8.3.3.2.2)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED IF ASTRAGALS ARE PRESENT (NFPA 80

6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" HIGH PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)

10.SWING IN DIRECTION OF EGRESS (NFPA 101 7.2.1.4.2)

11. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 80 5.2.4.1)

* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR LESS.

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE DAMPERS

ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE PROTECTED

BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.

ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE TO

BE FILLED ON BOTH SIDES OF THE WALL.

1. NON-LABELED FRAME (NFPA 101 18.3.7.6)

2. 20 MINUTE OR 1-3/4" SOLID WOOD CORE (NFPA 101 18/19.3.7.6)

3. VISION PANEL PERMITTED UP TO MAXIMUM SIZE TESTED (NFPA 101 TABLE

8.3.3.2.2)

4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18/19.3.7.8)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18/19.3.7.8)

6. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4.1)

8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1

9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)

10. ANNUAL PERIODIC INSPECTION AND TESTING (NFPA 180 5.2.4.1)

WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.

NO MINIMUM REQUIREMENTS.

NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED

CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED

WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.

NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING

IN AN EMERGENCY.

(COLOR #30)

(COLOR #2)

HEALTHCARE AREA OPEN TO CORRIDOR WITH 24/7

SUPERVISION - NO SMOKE DETECTION REQUIRED.

(COLOR #3)

HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE

DETECTION PROVIDED.

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1-HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

(COLOR #230)

(COLOR #4)

NON-RATED SMOKE BARRIER

SUBSTANTIAL WALLS AND DOORS TO SUBDIVIDE BUILDING SPACES FOR THE PURPOSE

OF RESTRICTING THE MOVEMENT OF SMOKE.

WALL: EXTENDS FROM FLOOR TO DECK ABOVE.

DUCTS: SMOKE DAMPERS ARE NOT REQUIRED WHERE STEEL DUCTS PENETRATE SMOKE

BARRIERS FORMING A COMMUNICATING SPACE SEPARATION.

PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH MATERIALS TO PREVENT THE

TRANSFER OF SMOKE. USE OF LISTED FIRE STOP MATERIALS IS NOT REQUIRED.

DOORS: 1. NON-LABELED FRAME (NFPA 101 8.5)

2. NON-FIRE-RATED DOOR (NFPA 101 8.5)

3. NO GRILLES OR LOUVERS ARE PERMITTED (NFPA 101 8.5.4.1)

4. POSITIVE LATCHING HARDWARE IS REQUIRES (NFPA 101 8.5.4.3)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.5.4.3)

6. MAXIMUM 3/4” UNDERCUT (NFPA 101 8.5.4.1)

7. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1)

8. SWING IN ANY DIRECTION IF FEWER THAN 50 OCCUPANTS (NFPA 101 7.2.1.4.2)

9. WINDOW ASSEMBLIES ARE NOT REQUIRED TO BE FIRE RATED (NFPA 101 7.2.1.4.2)

WALL:

DUCTS:

DOORS:

SMOKE-RESISTIVE HAZARDOUS ROOM ENCLOSURE

(COLOR #230) IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT

TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY

TERMINATE AT THE CEILING PER NFPA 101 8.4.2(3). IF THE ROOM DOES NOT HAVE A

SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE RATING AND SHALL

EXTEND TO THE DECK ABOVE PER NFPA 101 19.3.2.1.2.

STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS OR SMOKE DAMPERS.

ALL PENETRATIONS ARE SEALED WITH MATERIALS TO PREVENT THE TRANSFER OF

SMOKE. USE OF LISTED FIRESTOP MATERIALS IS NOT REQUIRED.

1. NON-LABELED FRAME (NFPA 101 8.4.2)

2. CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE. DOES NOT APPLY TO

TOILET, BATH, SHOWER, SINK OR SIMILAR ROOMS (NFPA 18/19.3.6.3.1,

18/19.3.6.3.2)

3. POSITIVE LATCHING REQUIRED IF OPENING TO HEALTH CARE CORRIDOR (NFPA

101 18/19.3.6.3.5)

4. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.4.3.5)

5. MAXIMUM 1/8" GAP (NFPA 101 8.4.3.4 & NFPA 80 6.3.1.7)

6. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.4.3.4 & NFPA 80 4.8.4.1)

7. PROTECTIVE PLATES PERMITTED TO BE UNLIMITED IN HEIGHT

8. SWING IN ANY DIRECTION IF FEWER THAN 50 OCCUPANTS (NFPA 101 7.2.1.4.2)

PENETRATIONS:

(COLOR #30)

EXIT STAIRWELL/PASSAGEWAY

OCCUPANCY/SMOKE ZONE BOUNDARY

FIRE/SMOKE BARRIER

DESCRIPTION

113,128, 200, 217, 221, 228

23400

DATEREVISIONS: NUMBER

DRAFT SOC 4/08/2024

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

KC LLC.

1330 BURLINGTON STREET, SUITE 200

NORTH KANSAS CITY, MO 64116

(816) 931-3377

FP&C CONSULTANTS,

JLB DJB

HINES, ILLINOIS

EDWARD HINES, JR. VA

STATEMENT OF CONDITIONS

DOCUMENTATIONEdward Hines, Jr.

VA Hospital 5000 5th Ave

Hines, IL 60141 Checked by Drawn by

Dwg. of 64

SOC X-1

578-24-002

FINAL SOC

06/19/2024

6/19/2024

OCCUPANCY TABLE

APPLICABLE CODES AND STANDARDS: FIRE SPRINKLER SYSTEM:

1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.

2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13 - 3.3.4.16).

3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 225 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).

4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15

GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).

5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT. DENSITY.

6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13 - 10.2.5.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS IN SMALL ROOMS (800 SQ. FT. MAXIMUM) SHALL NOT

EXCEED 9' FROM ANY SINGLE WALL (NFPA 13 - 10.2.5.2.3).

7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13 - 12.1.10.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE 2019 EDITION ON NFPA 13. SPRINKLERS NOT REQUIRED UNDER

NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13 - 9.5.5.3.1).

8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13 - 10.2.6.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13 - 10.2.6.1.2).

9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA 13 - 9.5.6.1).

10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE PER NFPA 13 - 9.2.5(2).

11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.1.2 AND FIGURE 10.2.7.1.2(a).

12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.2.2 AND FIGURE 10.2.7.2.2.

SUITES:

1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND TO DEFINE THE END OF PUBLIC EXIT

CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE MAY DIRECT OCCUPANTS INTO A SUITE TO REACH AN EXIT.

2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.

3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:

A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)

B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)

C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION - 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B) D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION - 10,000 SQ. FT. (NFPA

101 - 19.2.5.7.2.3.C)

4. PATIENT CARE NON - SLEEPING SUITES:

A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)

B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.3)

5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.

6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6

OF NFPA 101.

FIRE ALARM SYSTEM:

1. THE FIRE ALARM SYSTEM WAS DESIGNED TO 2019 EDITION OF NFPA 72, NATIONAL FIRE ALARM CODE.

2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2018 EDITION.

3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF NFPA

72 - 2019 EDITION.

4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72 - 2019

EDITION.

5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72 - 2019 EDITION.

6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA (NFPA 72 - 17.7.3.2.3.1)

7. SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS MAY

BE SPACED AT MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE (NFPA 72 - 17.7.5.6.1) SMOKE DETECTORS NOT CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 72- 17.7.5.6.

8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF CEILING HEIGHT SHALL HAVE REDUCED SMOKE DETECTOR SPACING

COVERAGE (NFPA 72 - 17.7.3.2.4.2).

9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE

DETECTOR (NFPA 72- 17.7.3.2.1).

10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).

1. THE ORIGINAL BUILDING WAS DESIGNED TO THE 1965 EDITION OF NFPA 101, LIFE SAFETY CODE.

2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW THE LATEST EDITIONS OF NATIONALLY

RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.

3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE CODES AND STANDARDS.

4. OTHER NFPA CODES AND STANDARDS:

A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2018 EDITION

B. NFPA 13 - SPRINKLER SYSTEMS, 2019 EDITION

C. NFPA 14 - STANDPIPE SYSTEMS, 2016 EDITION

D. NFPA 20 - FIRE PUMPS, 2019 EDITION

E. NFPA 25 - WATER-BASED FIRE PROTECTION SYSTEMS 2020 EDITION

F. NFPA 70 - NATIONAL ELECTRIC CODE, 2020 EDITION

G. NFPA 72 - NATIONAL FIRE ALARM CODE, 2019 EDITION

H. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION

I. NFPA 80 - FIRE DOORS, 2019 EDITION

J. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2018 EDITION

K. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2017 EDITION

L. NFPA 99 - HEALTH CARE FACILITIES CODE, 2018 EDITION

M. NFPA 105 - SMOKE DOORS, 2019 EDITION

N. NFPA 110 - EMERGENCY POWER SYSTEMS, 2019 EDITION

O. NFPA 241 - CONSTITUTION AND DEMOLITION, 2019 EDITION

1. EXITS (STAIRWAYS, HORIZONTAL EXITS AND DIRECT EXTERIOR EXIT DOORS), OTHER THAN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS. (GLASS DOORS, VISION PANELS OR ADJACENT WINDOWS) SHALL BE MARKED WITH EXIT SIGNAGE.

(SECTION 7.10.1.2.1 OF NFPA 101-2018 EDITION)

2. DIRECTIONAL SIGNS REQUIRED WHERE DIRECTION OF TRAVEL IS NOT APPARENT IN AN EXIT ACCESS CORRIDOR. (SECTION 7.10.2.1 OF NFPA

101-2018 EDITION)

3. DIRECTIONAL SIGNAGE (EXIT PLACARDS) REQUIRED WITHIN HORIZONTAL COMPONENTS OF EXIT STAIR ENCLOSURES WHERE EGRESS PATH

IS NOT OBVIOUS (SECTIONS 7.10.2.2 AND 7.10.1.2.2 OF NFPA 101-2018 EDITION)

4. MAXIMUM VIEWING DISTANCE TO AN EXIT SIGN IN AN EXIT ACCESS CORRIDOR IS 100 FT. (SECTION 7.10.1.5.2 OF NFPA 101-2018 EDITION)

5. EXIT SIGNS SHALL BE INSPECTED MONTHLY. (SECTION 7.10.9.1 IF NFPA 101-2018 EDITION)

6. DIRECTIONAL SIGNAGE (EXIT PLACARDS OR EXIT SIGNS) WITH OR WITHOUT DIRECTIONAL ARROWS SHOULD BE PROVIDED IN SUITES USED

BY THE GENERAL PUBLIC (LESS THAN 50 TOTAL OCCUPANTS) TO DIRECT THE GENERAL PUBLIC BACK TO THE WAITING AREA. (SECTION

7.10.2.1 OF NFPA 101-2018 EDITION)

7. ROOMS OR SUITES OF ROOMS USED FOR 50 OCCUPANTS OR MORE SHALL BE PROVIDED WITH EXIT SIGNAGE. (SECTIONS 13.2.10.1 AND

3.3.196.2 OF NFPA 101-2018 EDITION)

EXIT SIGN REQUIREMENTS

THE VA HAS ELECTIVE ACCREDITATION WITH THE JOINT COMMISSION (TJC) FOR HEALTH CARE FACILITIES. SEE THE MEMORANDUM OF UNDERSTANDING (EFFECTIVE 4 SEPTEMBER, 2017) BETWEEN THE VA AND TJC FOR IMPLEMENTATION OF TJC ENVIRONMENT OF CARE (EC) AND

LIFE SAFETY (LS) STANDARDS.

THE VA HAS ELECTIVE ACCREDITATION WITH THE LONG-TERM CARE INSTITUTE, INC. (LTCI) FOR COMMUNITY LIVING CENTERS (CLC). SEE THE CLARIFICATION MEMORANDUM (EFFECTIVE MARCH 29, BETWEEN THE VA AND THE LTCI FOR IMPLEMENTATION OF LIFE SAFETY REQUIREMENTS.

THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND APPROVED BY THE JOINT COMMISSION AND APPLY TO ALL BUILDINGS:

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS

2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50 FEET

3. INTERNAL SPRINKLER PIPING CONDITION AND OBSTRUCTION INVESTIGATION.

THE FOLLOWING SITE SPECIFIC EQUIVALENCIES HAVE BEEN APPROVED BY TJC:

1. BUILDING 200 MAIN HOSPITAL

A. LINEAR ACCELERATOR COMMON PATH OF TRAVEL

B. STAIR NO. 1 IS EXIT PASSAGEWAY

2. BUILDING 221 REHABILITATION CENTER

A. MODULAR BUILDING CONSTRUCTION SEPARATION

EQUIVALENCIES

CODE SUMMARY

AND OCCUPANCY TABLE ALL

23400

DATEREVISIONS: NUMBER

DRAFT SOC 4/08/2024

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

KC LLC.

1330 BURLINGTON STREET, SUITE 200

NORTH KANSAS CITY, MO 64116

(816) 931-3377

FP&C CONSULTANTS,

JLB DJB

HINES, ILLINOIS

EDWARD HINES, JR. VA

STATEMENT OF CONDITIONS

DOCUMENTATIONEdward Hines, Jr.

VA Hospital 5000 5th Ave

Hines, IL 60141 Checked by Drawn by

Dwg. of 64

SOC X-2

578-24-002

FINAL SOC

06/19/2024

6/19/2024

Building No. Floor Healthcare Ambulatory Health Care Business Industrial Storage Daycare Total

1 4 0 0 99,707 0 0 0 99,707 1 3 0 0 104,344 0 0 0 104,344 1 2 0 0 104,837 0 0 0 104,837 1 1 0 0 129,758 0 0 0 129,758 1 Subtotal 0 0 438,646 0 0 0 438,646

12 3 0 0 5,019 0 0 0 5,019 12 2 0 0 5,024 0 0 0 5,024 12 1 0 0 4,999 0 0 0 4,999 12 Basement 0 0 1,174 0 0 0 1,174 12 Subtotal 0 0 16,216 0 0 0 16,216 13 3 0 0 6,312 0 0 0 6,312 13 2 0 0 6,312 0 0 0 6,312 13 1 0 0 6,396 0 0 0 6,396 13 Basement 0 0 1,426 0 0 0 1,426 13 Subtotal 0 0 20,446 0 0 0 20,446

113 Penthouse 0 0 0 4,009 0 0 4,009 113 2 0 0 26,195 0 0 0 26,195 113 1 26,063 0 0 0 0 0 26,063 113 Subtotal 26,063 0 26,195 4,009 0 0 56,267 128 1 52,567 0 0 0 0 0 52,567 128 Basement 0 0 2,520 0 0 0 2,520 128 Subtotal 52,567 0 2,520 0 0 0 55,087 200 17 0 0 0 3,168 0 0 3,168 200 16 0 0 0 5,838 0 0 5,838 200 15 0 0 0 0 19,859 0 19,859 200 14 0 19,761 0 0 0 0 19,761 200 13 0 19,867 0 0 0 0 19,867 200 12 0 19,881 0 0 0 0 19,881 200 11 19,896 0 0 0 0 0 19,896 200 10 16,637 0 0 0 0 0 16,637 200 9 19,820 0 0 0 0 0 19,820 200 8 19,843 0 0 0 0 0 19,843 200 7 19,791 0 0 0 0 0 19,791 200 6 0 19,920 0 0 0 0 19,920 200 5 0 19,814 0 0 0 0 19,814 200 4 0 0 21,041 0 0 0 21,041 200 3 0 21,058 0 0 0 0 21,058 200 2 70,248 0 0 0 0 0 70,248 200 1 0 101,263 0 0 0 0 101,263 200 Basement 0 88,007 0 0 0 0 88,007 200 Subtotal 166,235 309,571 21,041 9,006 19,859 0 525,712 217 2 57,230 0 0 0 0 0 57,230 217 1 62,907 0 0 0 0 0 62,907 217 Subtotal 120,137 0 0 0 0 0 120,137 221 1 31,276 0 0 0 0 0 31,276 221 Subtotal 31,276 0 0 0 0 0 31,276 228 5 0 0 27,298 0 0 0 27,298 228 4 32,402 0 0 0 0 0 32,402 228 3 0 0 32,392 0 0 0 32,392 228 2 32,395 0 0 0 0 0 32,395 228 1 0 0 40,734 0 0 0 40,734 228 Basement 0 0 25,616 0 0 0 25,616 228 Subtotal 64,797 0 126,040 0 0 0 190,837

GRAND TOTAL 461,075 309,571 651,104 13,015 19,859 0 1,454,624

EX

EX

EX

ZONE 1BZONE 1A

ZONE 1BZONE 1A

EX

EX

EX

FACP

F

F

F

F

F

F

A E

D

A E

D

F FAAP

FIRST FLOOR

HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

BUILDING 113

BLIND REHAB

FIRST FLOOR

BUILDING 113

N

23400

DATEREVISIONS: NUMBER

DRAFT SOC 4/08/2024

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

KC LLC.

1330 BURLINGTON STREET, SUITE 200

NORTH KANSAS CITY, MO 64116

(816) 931-3377

FP&C CONSULTANTS,

JLB DJB

HINES, ILLINOIS

EDWARD HINES, JR. VA

STATEMENT OF CONDITIONS

DOCUMENTATIONEdward Hines, Jr.

VA Hospital 5000 5th Ave

Hines, IL 60141 Checked by Drawn by

Dwg. of 64

113SOC-1

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

578-24-002

APPROVED SITE EQUIVALENCIES

BUILDING 200 - MAIN HOSPITAL

1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.

2. STAIR NO. 1 EXIT PASSAGEWAY.

BUILDING 221 - REHABILITATION CENTER

1. MODULAR BUILDING CONSTRUCTION SEPARATION.

FINAL SOC

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

06/19/2024

6/19/2024

AutoCAD SHX Text

ENTRANCE CANOPY

AutoCAD SHX Text

COURTYARD

AutoCAD SHX Text B1A112

AutoCAD SHX Text B1A113

AutoCAD SHX Text B1A116

AutoCAD SHX Text B1A115

AutoCAD SHX Text B1A114

AutoCAD SHX Text B1A120

AutoCAD SHX Text B1A121

AutoCAD SHX Text B1A1117

AutoCAD SHX Text B1A120

AutoCAD SHX Text B1A127

AutoCAD SHX Text B1A128

AutoCAD SHX Text B1A129

AutoCAD SHX Text B1A123

AutoCAD SHX Text B1A131

AutoCAD SHX Text B1B100

AutoCAD SHX Text B1B100

AutoCAD SHX Text B1B103

AutoCAD SHX Text B1B106

AutoCAD SHX Text B1B107

AutoCAD SHX Text B1B109

AutoCAD SHX Text B1C4

AutoCAD SHX Text B1B106

AutoCAD SHX Text

B1ST2-1

AutoCAD SHX Text

B1ST2-2

AutoCAD SHX Text B1B114

AutoCAD SHX Text B1B115

AutoCAD SHX Text B1B116

AutoCAD SHX Text B1B117

AutoCAD SHX Text B1B119

AutoCAD SHX Text B1B122

AutoCAD SHX Text B1B121

AutoCAD SHX Text B1B124

AutoCAD SHX Text B1B127

AutoCAD SHX Text B1B130

AutoCAD SHX Text B1B132

AutoCAD SHX Text B1B129

AutoCAD SHX Text B1C6-2

AutoCAD SHX Text B1C6-3

AutoCAD SHX Text B1B136

AutoCAD SHX Text B1B137

AutoCAD SHX Text B1B139

AutoCAD SHX Text B1B138

AutoCAD SHX Text B1B141

AutoCAD SHX Text B122

AutoCAD SHX Text B121

AutoCAD SHX Text 1B1B125

AutoCAD SHX Text B1B143

AutoCAD SHX Text B1B148-1

AutoCAD SHX Text B127

AutoCAD SHX Text B1B148-3

AutoCAD SHX Text B1B151

AutoCAD SHX Text B1A152

AutoCAD SHX Text B1C7

AutoCAD SHX Text

B1ST1-1

AutoCAD SHX Text

B1ST1-2

AutoCAD SHX Text B1A132

AutoCAD SHX Text B1A133

AutoCAD SHX Text B1C3-1

AutoCAD SHX Text B1C3-2

AutoCAD SHX Text B1B101

AutoCAD SHX Text B1B104

AutoCAD SHX Text B1B108

AutoCAD SHX Text B1B105

AutoCAD SHX Text B1B110

AutoCAD SHX Text B1B112

AutoCAD SHX Text B109

AutoCAD SHX Text B110

AutoCAD SHX Text B1B120B

AutoCAD SHX Text B1B120

AutoCAD SHX Text B1B123

AutoCAD SHX Text B1B126

AutoCAD SHX Text B1B128

AutoCAD SHX Text B1B125

AutoCAD SHX Text B1B131

AutoCAD SHX Text B1B133

AutoCAD SHX Text B1B124

AutoCAD SHX Text B1B134

AutoCAD SHX Text B1B144

AutoCAD SHX Text B128

AutoCAD SHX Text B1B146

AutoCAD SHX Text B1B147

AutoCAD SHX Text B129

AutoCAD SHX Text B1C8-1

AutoCAD SHX Text B1C8-2

AutoCAD SHX Text B1B150

AutoCAD SHX Text B1B152

AutoCAD SHX Text B1A151

AutoCAD SHX Text B1A140

AutoCAD SHX Text B1A139

AutoCAD SHX Text B1A138

AutoCAD SHX Text B1A134

AutoCAD SHX Text B1A143

AutoCAD SHX Text B1A144

AutoCAD SHX Text B1A133

AutoCAD SHX Text B1A128

AutoCAD SHX Text B1A134

AutoCAD SHX Text B1C2

AutoCAD SHX Text B1A113

AutoCAD SHX Text B1A110

AutoCAD SHX Text B1A111

AutoCAD SHX Text B1C1-1

AutoCAD SHX Text B1C1-2

AutoCAD SHX Text B1A122

AutoCAD SHX Text B1A109

AutoCAD SHX Text B1A116

AutoCAD SHX Text B1A124A

AutoCAD SHX Text B1A126

AutoCAD SHX Text B1A135

AutoCAD SHX Text B1A138

AutoCAD SHX Text B1A140

AutoCAD SHX Text B1A141

AutoCAD SHX Text B1C9

AutoCAD SHX Text B1A110

AutoCAD SHX Text B1A107

AutoCAD SHX Text B1A105

AutoCAD SHX Text B1A108

AutoCAD SHX Text B1A106

AutoCAD SHX Text B1A109

AutoCAD SHX Text B1A100-1

AutoCAD SHX Text B1A100-2

AutoCAD SHX Text A151

AutoCAD SHX Text A149

AutoCAD SHX Text B1A160-2

AutoCAD SHX Text A150

AutoCAD SHX Text A149

AutoCAD SHX Text B1A166-1

AutoCAD SHX Text B1A162

AutoCAD SHX Text B1A161

AutoCAD SHX Text B1A159

AutoCAD SHX Text A143

AutoCAD SHX Text A144

AutoCAD SHX Text B1A156

AutoCAD SHX Text B1A150

AutoCAD SHX Text B1A148

AutoCAD SHX Text B1A147

AutoCAD SHX Text B1A145

AutoCAD SHX Text B1A103

AutoCAD SHX Text B1A104

AutoCAD SHX Text B1A114A

AutoCAD SHX Text B1A118A

AutoCAD SHX Text B1A125A

AutoCAD SHX Text B1A130A

AutoCAD SHX Text B1B103A

AutoCAD SHX Text B1B109A

AutoCAD SHX Text B1B101A

AutoCAD SHX Text B1A129A

AutoCAD SHX Text B1A123A

AutoCAD SHX Text B1A117A

AutoCAD SHX Text B1B114A

AutoCAD SHX Text B1B119A

AutoCAD SHX Text B1B127A

AutoCAD SHX Text B1B117A

AutoCAD SHX Text B1B124A

AutoCAD SHX Text B1B132A

AutoCAD SHX Text B1B131A

AutoCAD SHX Text B1B123A

AutoCAD SHX Text B1B120A

AutoCAD SHX Text B1B128A

AutoCAD SHX Text B1A149A

AutoCAD SHX Text B1A146A

AutoCAD SHX Text B1A139A

AutoCAD SHX Text B1A137A

AutoCAD SHX Text B1B110A

AutoCAD SHX Text B1B108A

AutoCAD SHX Text B1B102A

AutoCAD SHX Text B1A132A

AutoCAD SHX Text B1B150A

AutoCAD SHX Text B1B149A

AutoCAD SHX Text B1B145A

AutoCAD SHX Text B1B144A

AutoCAD SHX Text B1B139A

AutoCAD SHX Text

UP 25R

AutoCAD SHX Text

UP 25R

AutoCAD SHX Text B1A155A

AutoCAD SHX Text B1A166-2

AutoCAD SHX Text B1B136A

AutoCAD SHX Text B1C6-1

AutoCAD SHX Text

BEL1

AutoCAD SHX Text

BEL2

AutoCAD SHX Text B1B141

AutoCAD SHX Text 1B1A102

AutoCAD SHX Text 1B1A101

AutoCAD SHX Text 1B1C1

AutoCAD SHX Text 1B1A142

AutoCAD SHX Text 1B1A136

AutoCAD SHX Text B1C9

AutoCAD SHX Text B1C7

AutoCAD SHX Text B1C5

AutoCAD SHX Text 1B1C4

AutoCAD SHX Text B1C2

AutoCAD SHX Text

DINING HALL

AutoCAD SHX Text 1B152

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 1B117

AutoCAD SHX Text 1B116

AutoCAD SHX Text

AutoCAD SHX Text

OPEN

AutoCAD SHX Text 1B120

AutoCAD SHX Text 1B119

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text 1B126

AutoCAD SHX Text 1B128

AutoCAD SHX Text 1B129

AutoCAD SHX Text 1B130

AutoCAD SHX Text 1B118

AutoCAD SHX Text 1B115

AutoCAD SHX Text 1B114

AutoCAD SHX Text 1B111

AutoCAD SHX Text 1B113

AutoCAD SHX Text 1B112

AutoCAD SHX Text 1B108

AutoCAD SHX Text 1B104

AutoCAD SHX Text 1B105

AutoCAD SHX Text 1B103

AutoCAD SHX Text 1B102

AutoCAD SHX Text 1B100

AutoCAD SHX Text 1B101

AutoCAD SHX Text 1A122

AutoCAD SHX Text 1A123

AutoCAD SHX Text 1A121

AutoCAD SHX Text 1A120

AutoCAD SHX Text 1A117

AutoCAD SHX Text 1A114

AutoCAD SHX Text 1A113

AutoCAD SHX Text 1A115

AutoCAD SHX Text 1A116

AutoCAD SHX Text 1A106

AutoCAD SHX Text

AutoCAD SHX Text 1A128

AutoCAD SHX Text 1A133

AutoCAD SHX Text 1A134

AutoCAD SHX Text 1A138

AutoCAD SHX Text A139

AutoCAD SHX Text A140

AutoCAD SHX Text 1A141

AutoCAD SHX Text 1A142

AutoCAD SHX Text 1A143

AutoCAD SHX Text 1A145

AutoCAD SHX Text 1A146

AutoCAD SHX Text 1A148

AutoCAD SHX Text 1A149

AutoCAD SHX Text 1A150

AutoCAD SHX Text 1A151

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

WORKOUT

AutoCAD SHX Text

OIT

AutoCAD SHX Text

ELEC

AutoCAD SHX Text

OIT

AutoCAD SHX Text 1A119

AutoCAD SHX Text 1A125

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text B110

AutoCAD SHX Text

HAC

AutoCAD SHX Text

WOMENS

AutoCAD SHX Text

MENS

AutoCAD SHX Text 1A137

AutoCAD SHX Text 1A136

AutoCAD SHX Text 1A137

AutoCAD SHX Text

TLT.

AutoCAD SHX Text

FEMALE

AutoCAD SHX Text

TLT.

AutoCAD SHX Text

MALE

AutoCAD SHX Text

HALL

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

RISER ROOM

AutoCAD SHX Text

ADMINISTRATION

AutoCAD SHX Text 2,210 Sq. Ft.

AutoCAD SHX Text

AutoCAD SHX Text

NON PATIENT CARE

AutoCAD SHX Text

SUITE

ZONE 2BZONE 2A

ZONE 2BZONE 2A

F

FAED

A E

D

EW

EW

SECOND FLOOR

BUSINESS OCCUPANCY

FULLY SPRINKLERED

BUILDING 113

N

SECOND FLOOR

BUILDING 113

23400

DATEREVISIONS: NUMBER

DRAFT SOC 4/08/2024

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

KC LLC.

1330 BURLINGTON STREET, SUITE 200

NORTH KANSAS CITY, MO 64116

(816) 931-3377

FP&C CONSULTANTS,

JLB DJB

HINES, ILLINOIS

EDWARD HINES, JR. VA

STATEMENT OF CONDITIONS

DOCUMENTATIONEdward Hines, Jr.

VA Hospital 5000 5th Ave

Hines, IL 60141 Checked by Drawn by

Dwg. of 64

113SOC-2

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

578-24-002

APPROVED SITE EQUIVALENCIES

BUILDING 200 - MAIN HOSPITAL

1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.

2. STAIR NO. 1 EXIT PASSAGEWAY.

BUILDING 221 - REHABILITATION CENTER

1. MODULAR BUILDING CONSTRUCTION SEPARATION.

FINAL SOC

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

06/19/2024

6/19/2024

AutoCAD SHX Text

O+M SUPER.

AutoCAD SHX Text

M.S. WOOD/ LEATHER SHOP

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

LEATHER WEAVING & CERAMICS

AutoCAD SHX Text

M.S.HOME MECH

AutoCAD SHX Text

M.S. ASSESS

AutoCAD SHX Text

KILN

AutoCAD SHX Text

PREP. RM.

AutoCAD SHX Text

OIT

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

FINISH RM.

AutoCAD SHX Text

CONTINUE ED. RESOURCE RM.

AutoCAD SHX Text

ELEV.#2

AutoCAD SHX Text

MECH. SHAFT

AutoCAD SHX Text

MULTI-PURPOSE

AutoCAD SHX Text

TRAINING KITCHEN

AutoCAD SHX Text

LS CLASSROOM

AutoCAD SHX Text

CAT EQUIP.

AutoCAD SHX Text

LS CLASSROOM

AutoCAD SHX Text

LS CLASSROOM

AutoCAD SHX Text

MECH. CHASE

AutoCAD SHX Text

CAT 1

AutoCAD SHX Text

CAT 2

AutoCAD SHX Text

CAT 4

AutoCAD SHX Text

CAT 3

AutoCAD SHX Text

CAT 5

AutoCAD SHX Text

CAT 6

AutoCAD SHX Text

CAT ASSESS

AutoCAD SHX Text

CAT SUPER

AutoCAD SHX Text

OPT RESEARCH

AutoCAD SHX Text

OPT EXAM

AutoCAD SHX Text

HUMPHREY

AutoCAD SHX Text

EYE LANE

AutoCAD SHX Text

EYE LANE

AutoCAD SHX Text

VS-1

AutoCAD SHX Text

CCTV CLASSROOM

AutoCAD SHX Text

ELECT.

AutoCAD SHX Text

WAIT.

AutoCAD SHX Text

CAT SPECIALIST

AutoCAD SHX Text

CAT SPECIALIST

AutoCAD SHX Text

EVALUATION

AutoCAD SHX Text

O+M STORAGE

AutoCAD SHX Text

LS CLASSROOM

AutoCAD SHX Text

LS SPECIALIST OFFICES

AutoCAD SHX Text

STAFF LOCKERS

AutoCAD SHX Text

LS FAMILY TRAINING

AutoCAD SHX Text

ELECT.

AutoCAD SHX Text

LS FAMILY TRAINING

AutoCAD SHX Text

LS CLASSRM.

AutoCAD SHX Text

O+M SPEC.

AutoCAD SHX Text

O+M COORD.

AutoCAD SHX Text

LS SUPER.

AutoCAD SHX Text

TRAINING KITCHEN

AutoCAD SHX Text

TRAINING KITCHEN

AutoCAD SHX Text

LS CLASSRM. / DINING RM.

AutoCAD SHX Text

O+M SPECIALIST

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

ELEV.#1

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

OIT

AutoCAD SHX Text

HAC

AutoCAD SHX Text

LS STORAGE

AutoCAD SHX Text

VS-2

AutoCAD SHX Text

VS-3

AutoCAD SHX Text

VS-4

AutoCAD SHX Text

VS-6

AutoCAD SHX Text

VS-5

AutoCAD SHX Text

VS SPECIALIST

AutoCAD SHX Text

VS SUPERVISOR

AutoCAD SHX Text

OPTION OFFICE

AutoCAD SHX Text

OPTION RESIDENT & STUDENT

AutoCAD SHX Text

ECCENTRIC TRAINING

AutoCAD SHX Text

VS-6

AutoCAD SHX Text

MS STAFF

AutoCAD SHX Text

VS STORAGE

AutoCAD SHX Text

MS SUPER. OFFICE

AutoCAD SHX Text

SMALL ENGINE REPAIR

AutoCAD SHX Text

HAC

AutoCAD SHX Text B2A215

AutoCAD SHX Text B2A118

AutoCAD SHX Text B2A117

AutoCAD SHX Text B2A119

AutoCAD SHX Text B2A120

AutoCAD SHX Text B2A121

AutoCAD SHX Text B2A123

AutoCAD SHX Text B2A125

AutoCAD SHX Text B2A126

AutoCAD SHX Text B2A128

AutoCAD SHX Text B2A129

AutoCAD SHX Text B2B100

AutoCAD SHX Text B2B102

AutoCAD SHX Text B2B104

AutoCAD SHX Text B2B105

AutoCAD SHX Text B207

AutoCAD SHX Text B2B109

AutoCAD SHX Text B2B111

AutoCAD SHX Text B213

AutoCAD SHX Text

B2ST2

AutoCAD SHX Text B215

AutoCAD SHX Text B2C5

AutoCAD SHX Text B2A114

AutoCAD SHX Text A213

AutoCAD SHX Text B2A114A

AutoCAD SHX Text A222

AutoCAD SHX Text B2A124

AutoCAD SHX Text B2A127

AutoCAD SHX Text B2A130

AutoCAD SHX Text 2A230

AutoCAD SHX Text B201

AutoCAD SHX Text B2B103

AutoCAD SHX Text B2B106

AutoCAD SHX Text B208

AutoCAD SHX Text B2B110

AutoCAD SHX Text B2B112

AutoCAD SHX Text B2B114

AutoCAD SHX Text B216

AutoCAD SHX Text B2B117-1

AutoCAD SHX Text B2B117-2

AutoCAD SHX Text B219

AutoCAD SHX Text B2B121-2

AutoCAD SHX Text B2B121-1

AutoCAD SHX Text B225

AutoCAD SHX Text B2B126

AutoCAD SHX Text B2B127-2

AutoCAD SHX Text B227

AutoCAD SHX Text B229

AutoCAD SHX Text B2B130

AutoCAD SHX Text B2B131

AutoCAD SHX Text B2C6

AutoCAD SHX Text B228

AutoCAD SHX Text B224

AutoCAD SHX Text B2B122

AutoCAD SHX Text B2B123

AutoCAD SHX Text B2B120

AutoCAD SHX Text B2B118

AutoCAD SHX Text B233

AutoCAD SHX Text B2B235

AutoCAD SHX Text B236

AutoCAD SHX Text B2B136-2

AutoCAD SHX Text B2B134-1

AutoCAD SHX Text B2B134-2

AutoCAD SHX Text B2B132

AutoCAD SHX Text B2B139

AutoCAD SHX Text B2B140

AutoCAD SHX Text B2C7

AutoCAD SHX Text B2B138

AutoCAD SHX Text B2B137

AutoCAD SHX Text B2A100

AutoCAD SHX Text B2A235

AutoCAD SHX Text B2A234

AutoCAD SHX Text 2A234

AutoCAD SHX Text A233

AutoCAD SHX Text B2A131

AutoCAD SHX Text B2A133

AutoCAD SHX Text A206A

AutoCAD SHX Text A211

AutoCAD SHX Text B2A112

AutoCAD SHX Text B2A106-1

AutoCAD SHX Text A206

AutoCAD SHX Text B2A102

AutoCAD SHX Text A201

AutoCAD SHX Text B2A109

AutoCAD SHX Text B2A110

AutoCAD SHX Text B2A108

AutoCAD SHX Text B2A107

AutoCAD SHX Text A205

AutoCAD SHX Text B2A105-2

AutoCAD SHX Text B2A105-3

AutoCAD SHX Text B2A204

AutoCAD SHX Text A203

AutoCAD SHX Text B2A117A

AutoCAD SHX Text

B2ST1

AutoCAD SHX Text

DN 25R

AutoCAD SHX Text

DN 25R

AutoCAD SHX Text

UP 25R

AutoCAD SHX Text

BUILDING 228

AutoCAD SHX Text

OPEN TO BELOW

AutoCAD SHX Text

LINK ROOF

AutoCAD SHX Text

CANOPY BELOW

AutoCAD SHX Text B2C1

AutoCAD SHX Text

BEL1

AutoCAD SHX Text

BEL2

AutoCAD SHX Text B2C2

AutoCAD SHX Text B2C4

AutoCAD SHX Text 2B2C7

AutoCAD SHX Text B2C6

AutoCAD SHX Text B2C5

AutoCAD SHX Text B2B133A

AutoCAD SHX Text B2C3

AutoCAD SHX Text 2A233A

AutoCAD SHX Text 2B230

AutoCAD SHX Text 2B231

AutoCAD SHX Text 2B229

AutoCAD SHX Text 2B227

AutoCAD SHX Text 2B226

AutoCAD SHX Text 2B225

AutoCAD SHX Text 2B222

AutoCAD SHX Text 2B223

AutoCAD SHX Text 2B224

AutoCAD SHX Text 2B221

AutoCAD SHX Text 2B220

AutoCAD SHX Text 2B219

AutoCAD SHX Text 2B217

AutoCAD SHX Text B216

AutoCAD SHX Text B215

AutoCAD SHX Text 2B211

AutoCAD SHX Text 2B210

AutoCAD SHX Text 2A207

AutoCAD SHX Text 2A206

AutoCAD SHX Text 2A203

AutoCAD SHX Text 2A202

AutoCAD SHX Text 2A200

AutoCAD SHX Text 2A229

AutoCAD SHX Text 2A228

AutoCAD SHX Text 2A227

AutoCAD SHX Text 2A225

AutoCAD SHX Text 2A221

AutoCAD SHX Text 2A220

AutoCAD SHX Text 2A219

AutoCAD SHX Text 2A218

AutoCAD SHX Text 2A215

AutoCAD SHX Text 2A123

AutoCAD SHX Text 2A231

AutoCAD SHX Text 2A201

AutoCAD SHX Text 2A204

AutoCAD SHX Text 2A205

AutoCAD SHX Text 2B208

AutoCAD SHX Text 2B209

AutoCAD SHX Text 2B214

AutoCAD SHX Text 2B218

AutoCAD SHX Text 2A203

AutoCAD SHX Text 2A204

AutoCAD SHX Text 2A205

AutoCAD SHX Text 2A207

AutoCAD SHX Text 2B236B

AutoCAD SHX Text 2B236A

AutoCAD SHX Text 2A235

AutoCAD SHX Text 2B234

AutoCAD SHX Text 2B232

AutoCAD SHX Text 2B233

AutoCAD SHX Text 2B235

AutoCAD SHX Text 2B236

AutoCAD SHX Text 2A200

AutoCAD SHX Text

MENS

AutoCAD SHX Text 2A202

AutoCAD SHX Text

WOMENS

AutoCAD SHX Text 2A201

AutoCAD SHX Text 2A211

AutoCAD SHX Text 2A212

AutoCAD SHX Text A232

AutoCAD SHX Text 2A223

AutoCAD SHX Text 2A124

AutoCAD SHX Text

F

PENTHOUSE FLOOR

INDUSTRIAL OCCUPANCY

FULLY SPRINKLERED

BUILDING 113

THIRD FLOOR

BUILDING 113

N

23400

DATEREVISIONS: NUMBER

DRAFT SOC 4/08/2024

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

KC LLC.

1330 BURLINGTON STREET, SUITE 200

NORTH KANSAS CITY, MO 64116

(816) 931-3377

FP&C CONSULTANTS,

JLB DJB

HINES, ILLINOIS

EDWARD HINES, JR. VA

STATEMENT OF CONDITIONS

DOCUMENTATIONEdward Hines, Jr.

VA Hospital 5000 5th Ave

Hines, IL 60141 Checked by Drawn by

Dwg. of 64

113SOC-PH

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

578-24-002

APPROVED SITE EQUIVALENCIES

BUILDING 200 - MAIN HOSPITAL

1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.

2. STAIR NO. 1 EXIT PASSAGEWAY.

BUILDING 221 - REHABILITATION CENTER

1. MODULAR BUILDING CONSTRUCTION SEPARATION.

FINAL SOC

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

06/19/2024

6/19/2024

AutoCAD SHX Text

B3ST1

AutoCAD SHX Text B3A101

AutoCAD SHX Text B3A102

AutoCAD SHX Text

DN 25R

AutoCAD SHX Text B3A100-1

AutoCAD SHX Text B3A100-2

AutoCAD SHX Text

OPEN TO BELOW

AutoCAD SHX Text

MECHANICAL EQUIPMENT

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

AutoCAD SHX Text

ELEV 1 EQUIP.

ELEV 2 EQUIP.

HE

BASEMENT

BUSINESS OCCUPANCY

FULLY SPRINKLERED

BUILDING 128

BASEMENT

BUILDING 128

N

23400

DATEREVISIONS: NUMBER

DRAFT SOC 4/08/2024

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

KC LLC.

1330 BURLINGTON STREET, SUITE 200

NORTH KANSAS CITY, MO 64116

(816) 931-3377

FP&C CONSULTANTS,

JLB DJB

HINES, ILLINOIS

EDWARD HINES, JR. VA

STATEMENT OF CONDITIONS

DOCUMENTATIONEdward Hines, Jr.

VA Hospital 5000 5th Ave

Hines, IL 60141 Checked by Drawn by

Dwg. of 64

128SOC-B

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

578-24-002

APPROVED SITE EQUIVALENCIES

BUILDING 200 - MAIN HOSPITAL

1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.

2. STAIR NO. 1 EXIT PASSAGEWAY.

BUILDING 221 - REHABILITATION CENTER

1. MODULAR BUILDING CONSTRUCTION SEPARATION.

FINAL SOC

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

06/19/2024

6/19/2024

AutoCAD SHX Text

SBA100

AutoCAD SHX Text

SBA101

AutoCAD SHX Text

SBST1

AutoCAD SHX Text

SBA104

AutoCAD SHX Text

SBA103

AutoCAD SHX Text

UP 24R

AutoCAD SHX Text

SBA102

AutoCAD SHX Text

SBA106

AutoCAD SHX Text

SBA105

AutoCAD SHX Text

SBA107

AutoCAD SHX Text

UNASSIGNED

AutoCAD SHX Text

PATIENT STORAGE

AutoCAD SHX Text

HEALTH CARE TECHNOLOGY MANAGEMENT

AutoCAD SHX Text

ELEVATOR MACHINE RM.

AutoCAD SHX Text

TELE COM

AutoCAD SHX Text

ELEV. #1

AutoCAD SHX Text

ELEV. #2

AutoCAD SHX Text

SEL1

AutoCAD SHX Text

SEL2

AutoCAD SHX Text

SBC1

AutoCAD SHX Text

SBC2

AutoCAD SHX Text

TO BUILDING 200

AutoCAD SHX Text S003

AutoCAD SHX Text S002

AutoCAD SHX Text S001

AutoCAD SHX Text S004

EX

EXEX

EX

NORTH WARD SOUTH WARD

EXCENTER WARD

2 BUILDING 128 BUILDING 200

F

F

F A

A P

F

F

F

F A

C P

F

F

CENTER WARD

F

F

F

F

BUILDING 128

PENTHOUSE

FIRST FLOOR

HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

SUITE DESCRIPTIONS

KEY NOTES:

BUILDING 128

N

FIRST FLOOR

BUILDING 128

23400

DATEREVISIONS: NUMBER

DRAFT SOC 4/08/2024

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

KC LLC.

1330 BURLINGTON STREET, SUITE 200

NORTH KANSAS CITY, MO 64116

(816) 931-3377

FP&C CONSULTANTS,

JLB DJB

HINES, ILLINOIS

EDWARD HINES, JR. VA

STATEMENT OF CONDITIONS

DOCUMENTATIONEdward Hines, Jr.

VA Hospital 5000 5th Ave

Hines, IL 60141 Checked by Drawn by

Dwg. of 64

128SOC-1

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

578-24-002

APPROVED SITE EQUIVALENCIES

BUILDING 200 - MAIN HOSPITAL

1. LINEAR ACCELERATOR COMMON PATH OF TRAVEL.

2. STAIR NO. 1 EXIT PASSAGEWAY.

BUILDING 221 - REHABILITATION CENTER

1. MODULAR BUILDING CONSTRUCTION SEPARATION.

FINAL SOC

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

06/19/2024

6/19/2024

SMOKE ZONE SQ. FT. OCCUPANCY

SMOKE ZONE SIZE

AutoCAD SHX Text

UP 28R

AutoCAD SHX Text

UP 28R

AutoCAD SHX Text C1-1A

AutoCAD SHX Text P.N4

AutoCAD SHX Text C1-1A

AutoCAD SHX Text

TUNNEL BELOW

AutoCAD SHX Text

SEMI S.4

AutoCAD SHX Text

SEMI N.4

AutoCAD SHX Text

SEMI S.9

AutoCAD SHX Text

SEMI S.8

AutoCAD SHX Text

SEMI S.7

AutoCAD SHX Text

SEMI N.3

AutoCAD SHX Text

SEMI N.2

AutoCAD SHX Text

SEMI S.2

AutoCAD SHX Text

SEMI S.3

AutoCAD SHX Text

MED. EQUIP.

AutoCAD SHX Text

NURSE STATION

AutoCAD SHX Text

CLEAN LINEN

AutoCAD SHX Text

SOILED UTILITY

AutoCAD SHX Text P.N5

AutoCAD SHX Text P.N6

AutoCAD SHX Text P.N4

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

HAC

AutoCAD SHX Text

SOILED LINEN

AutoCAD SHX Text

HEAD NURSE

AutoCAD SHX Text

DOCTOR

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

TEL ROOM

AutoCAD SHX Text

ELECT.

AutoCAD SHX Text

TEL.

AutoCAD SHX Text

ELEV.#1

AutoCAD SHX Text

ELEV.#2

AutoCAD SHX Text

EXAM 5

AutoCAD SHX Text

EXAM 1

AutoCAD SHX Text

EXAM 4

AutoCAD SHX Text

EXAM 2

AutoCAD SHX Text

EXAM 3

AutoCAD SHX Text

SOILED LINEN

AutoCAD SHX Text

NURSE

AutoCAD SHX Text

SCHED.

AutoCAD SHX Text

INTERVIEW

AutoCAD SHX Text

TRAINING

AutoCAD SHX Text

NURSE OFFICE

AutoCAD SHX Text

ADL TOILET

AutoCAD SHX Text

SOCIAL WORK

AutoCAD SHX Text

PATIENT WAITING

AutoCAD SHX Text

DRESS

AutoCAD SHX Text

CLEAN

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text P.N1

AutoCAD SHX Text P.N3

AutoCAD SHX Text P.N2

AutoCAD SHX Text

RESIDENT

AutoCAD SHX Text

STAFF TOILET

AutoCAD SHX Text

COURTYARD

AutoCAD SHX Text

SEMI. S.1

AutoCAD SHX Text

REPORT

AutoCAD SHX Text

MEDICATIONS

AutoCAD SHX Text

NOURISH

AutoCAD SHX Text

CLEAN UTILITY

AutoCAD SHX Text

NURSE OFFICE

AutoCAD SHX Text

COORD. OFFICE

AutoCAD SHX Text

SEC.

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

NURSE OFFICE

AutoCAD SHX Text

NURSE OFFICE

AutoCAD SHX Text

PUBLIC WAIT.

AutoCAD SHX Text

SEC.

AutoCAD SHX Text

SEC.

AutoCAD SHX Text

CHIEF

AutoCAD SHX Text

EDUC. THERAPY

AutoCAD SHX Text

TEL.

AutoCAD SHX Text

ELECT.

AutoCAD SHX Text

PRIVATE FAMILY WAITING

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

SEMI S.5

AutoCAD SHX Text

ISO S.1

AutoCAD SHX Text

SEMI N9

AutoCAD SHX Text

SEMI N.8

AutoCAD SHX Text

ISO N.1

AutoCAD SHX Text

ISO N2

AutoCAD SHX Text

SEMI N5

AutoCAD SHX Text

SEMI N6

AutoCAD SHX Text

SEMI N7

AutoCAD SHX Text

BREAK

AutoCAD SHX Text

SEMI N.4

AutoCAD SHX Text

SEMI

AutoCAD SHX Text

SEMI N.2

AutoCAD SHX Text

SEMI N.1

AutoCAD SHX Text

NURSE STATION NORTH

AutoCAD SHX Text

MAJOR MED. EQUIP.

AutoCAD SHX Text

ELECT.

AutoCAD SHX Text

SEMI S.10

AutoCAD SHX Text

SEMI

AutoCAD SHX Text

SEMI S13

AutoCAD SHX Text

SEMI S12

AutoCAD SHX Text

MED. EQUIP.

AutoCAD SHX Text

MEDICATION

AutoCAD SHX Text

CLEAN LINEN

AutoCAD SHX Text

SOILED UTILITY

AutoCAD SHX Text

SOILED LINEN

AutoCAD SHX Text

PT EQUIP.

AutoCAD SHX Text

CLEAN UTILITY

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text P.N1

AutoCAD SHX Text

PVA COUNSELOR

AutoCAD SHX Text P.N2

AutoCAD SHX Text P.N3

AutoCAD SHX Text

DOCTOR

AutoCAD SHX Text

SOCIAL WORKER

AutoCAD SHX Text P.N5

AutoCAD SHX Text P.N6

AutoCAD SHX Text

STAFF LOCKER RM.

AutoCAD SHX Text

DOCTOR OFFICE

AutoCAD SHX Text

DOCTOR OFFICE

AutoCAD SHX Text

DOCTOR OFFICE

AutoCAD SHX Text

DOCTOR OFFICE

AutoCAD SHX Text

DOCTOR OFFICE

AutoCAD SHX Text

PSYCH OFFICE

AutoCAD SHX Text

PSYCH OFFICE

AutoCAD SHX Text

INTERVIEW

AutoCAD SHX Text

S.C.I HOME CARE

AutoCAD SHX Text

HEALTH TECH OFFICE

AutoCAD SHX Text

TEL.

AutoCAD SHX Text

SOC. WK. OFFICE

AutoCAD SHX Text

CONF.

AutoCAD SHX Text

ADMIN. OFFICE

AutoCAD SHX Text

MULTI-PURPOSE

AutoCAD SHX Text

DINING

AutoCAD SHX Text

HEAD NURSE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

HAC

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

QUIET TREATMENT

AutoCAD SHX Text

ADL

AutoCAD SHX Text

MECH -FIRE

AutoCAD SHX Text

PT/KT

AutoCAD SHX Text

SUB-WAITING

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

SEMI N.1

AutoCAD SHX Text

SPECIAL CARE NURSE STATION

AutoCAD SHX Text

ELECT.

AutoCAD SHX Text

ISO S.2

AutoCAD SHX Text

ISO S.6

AutoCAD SHX Text

NC

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

NC

AutoCAD SHX Text

DN

AutoCAD SHX Text 1A108

AutoCAD SHX Text 1A109

AutoCAD SHX Text 1A111

AutoCAD SHX Text 1A113

AutoCAD SHX Text 1A115

AutoCAD SHX Text 1A117

AutoCAD SHX Text 1A120

AutoCAD SHX Text 1A110

AutoCAD SHX Text 1A112

AutoCAD SHX Text 1A114

AutoCAD SHX Text 1A116

AutoCAD SHX Text 1A121

AutoCAD SHX Text 1A100D

AutoCAD SHX Text 1A100E

AutoCAD SHX Text 1A122

AutoCAD SHX Text 1A123

AutoCAD SHX Text 1A124

AutoCAD SHX Text 1A100B

AutoCAD SHX Text 1A100

AutoCAD SHX Text 1A100C

AutoCAD SHX Text 1C147

AutoCAD SHX Text 1C145

AutoCAD SHX Text 1C142

AutoCAD SHX Text 1C138

AutoCAD SHX Text 1C146

AutoCAD SHX Text 1C144

AutoCAD SHX Text 1C100

AutoCAD SHX Text 1C102

AutoCAD SHX Text 1C103

AutoCAD SHX Text 1C105

AutoCAD SHX Text 1C143

AutoCAD SHX Text 1C141

AutoCAD SHX Text 1C140

AutoCAD SHX Text 1C107

AutoCAD SHX Text 1C101

AutoCAD SHX Text 1C104

AutoCAD SHX Text 1C106

AutoCAD SHX Text 1A148A

AutoCAD SHX Text 1A148

AutoCAD SHX Text A149

AutoCAD SHX Text 1A134

AutoCAD SHX Text 1A135

AutoCAD SHX Text 1A127

AutoCAD SHX Text 1A128

AutoCAD SHX Text 1A131

AutoCAD SHX Text 1A133

AutoCAD SHX Text 1A133B

AutoCAD SHX Text 1A129

AutoCAD SHX Text 1A130

AutoCAD SHX Text 1A132

AutoCAD SHX Text 1A133A

AutoCAD SHX Text 1A137

AutoCAD SHX Text 1A139

AutoCAD SHX Text 1A142

AutoCAD SHX Text 1A143

AutoCAD SHX Text 1A138

AutoCAD SHX Text 1A140

AutoCAD SHX Text 1A141

AutoCAD SHX Text 1A144

AutoCAD SHX Text 1A145

AutoCAD SHX…

This is the start of the file's text. The full file is on GovTribe.