S06 36C25222B0022 0002 Att3 DWG E401-A - THIRD FLOOR FA PLAN - A WING.pdf
PDF 279 KB Posted
- Attached to
- Z1DA--Project 556-20-013 Renovate Bldg 134 CLC 3A/C at the Captain James A. Lovell FHCC in North Chicago, IL
- Solicitation number
- 36C25222B0022
About this file
This document package includes construction drawings and specifications for a federal contract opportunity to renovate building 134 at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois. The drawings show fire alarm plans for the third floor of the A and C wings, and call for work including eliminating areas in the A wing, installing smoke detectors, flow and tamper switches for fire protection piping, and labeling of devices, panels and conduit. The related solicitation is for project 556-20-013 to renovate the 3A/3C areas of building 134 at the FHCC in North Chicago, with the contracting agency being the Department of Veterans Affairs Veterans Health Administration VISN 12.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Microwave
SD
V
V
F
V
F
F
SD
SD
F
V
F
F
SD
F F
F V
V
F F
F
V
F
SD
D H
D H
SD
SD
SD
SD
SD
SD
SD SD
DH
DH
SD SD
FS
TS
FS
TS
SD SD
SD
F F
N
F G H
J.4
J.2F.2
BATHING SUITE
A319
EQUIPMENT STORAGE
A318
ELECTRICAL
A315A
CORRIDOR
C3
STAFF LOUNGE
A320
STAFF LOCKERS
A320A
STAFF TOILET
A320B
SEMI-PRIVATE OFFICE
A316
ELEVATOR LOBBY
A304
SERVICE ELEVATOR LOBBY
A315
ELEVATOR
S-1
ELEVATOR
P-1
MULTIPURPOSE ROOM
A313
ELEVATOR LOBBY
A304
ELEVATOR
P-2
BUILDING CONNECTION
A300
BIOHAZARD STORAGE
A301
SEMI-PRIVATE OFFICE
A302 STAIR
STAFF TOILET
A305B
HAC
A304
STAFF LOCKERS
A305A
STAFF LOUNGE
A305
PUBLIC TOILET
A312
FAMILY LOUNGE
A311 EQUIPMENT STORAGE
A310
BATHING SUITE
A306
LAUNDRY
B332
SPD STORAGE
A307
CORRIDOR
C2
IT
A315B
COMM
A317
CLOSET
A313B
ALTERNATE 1:
ELIMINATE WORK
IN A WING, THIS
AREA
ALTERNATE 1:
ELIMINATE WORK
IN A WING, THIS
AREA
Jy KyHzFx Hx
Jx Kx Lx
1 1
E501
Sim
LAUNDRY
C302
SOILED UTILITY
C301
A WING B WING
C WING
KEY PLAN
I LL IN O IS
R
.E
SS
E J
FARBE
LICENSED
PROFESSIONAL
OF
ENGINEER
062.069980
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
15% SCHEMATIC DESIGN 06/10/2021
30% SCHEMATIC DESIGN 08/04/2021
50% DESIGN DEVELOPMENT 09/12/2021
75% DESIGN DEVELOPMENT 11/11/2021
95% CONSTRUCTION DOCUMENTS 12/09/2021
100% BID DOCUMENTS 12/23/2021
100% BID DOCUMENTS - REVISION 01/31/2022
C U s e rs \b w o z n ie w s k i\ D o c u m e n ts
\I X
L H
E
L E
C
R b w o z n ie w s k iJ
B
X L .r v t
/1
/2
:0
:3
A
M
E401.A
THIRD FLOOR FIRE ALARM PLAN -
A WINGGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
CMTA
9225 PRIORTY WAY DRIVE SUITE 130
INDIANAPOLIS, IN 46240
RENOVATE B134-3AC CLC
3001 GREEN BAY ROAD, NORTH
CHICAGO, IL 60061
556-20-013
12/23/2021 BKB BJW
100% BID DOCUMENTS
FULLY SPRINKLERED
317.703.6226
SCALE: 1/8" = 1'-0"
THIRD FLOOR FIRE ALARM PLAN - A WING
PLAN NOTES:
1 SMOKE DETECTOR FOR DOOR RELEASE.
2 PROVIDE FLOW AND TAMPER SWITHES FOR FIRE PROTECTION PIPING.
Revisions: Date:
AMENDMENT #2 07/15/2022
A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND
CASEWORK DETAILS FOR EXACT LOCATIONS OF ALL WALL AND CEILING MOUNTED
ELECTRICAL DEVICES.
B. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL DEVICES IN AREA OF
CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS WITH BLACK LETTERING. IN
HEALTHCARE FACILITIES, ENGRAVE EMERGENCY DEVICE COVERPLATES IN PATIENT
CARE AREAS. MARK INSIDES OF ALL DEVICE BOXES WITH PANEL AND CIRCUIT
NUMBER.
C. REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND SHEET) AND
SPECIFICATIONS FOR REQUIREMENTS OF EACH SYSTEM.
D. ROUTE ALL ''SYSTEM CONDUIT STUB-UPS'' TO THE NEAREST CORRIDOR CABLING PATH
(SEE ''STUB-UP'' DETAILS). REFER TO CABLING PATH INSTALLATION DETAIL FOR
ADDITIONAL REQUIREMENTS.
E. PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT BLUE FOR SYSTEMS CABLING INTO
THE CORRIDOR CABLING PATH. PROVIDE PULL STRINGS IN ALL NEW CONDUIT RUNS
FOR SYSTEM CABLING INSTALLATION.
F. REFER TO FIRE PROTECTION PLANS FOR FIRE PROTECTION ZONES AND LABELING.
G. PROVIDE 120V LIFE SAFETY CIRCUIT FOR PATIENT ROOM SMOKE DETECTORS.
1 1
| Sheets |
| E401.A - THIRD FLOOR FIRE ALARM PLAN - A WING |
| E401.C - THIRD FLOOR FIRE ALARM PLAN - C WING |
File details come from the government source that posted it. Updated .