S06 - Att 03 - BLDG 48 REEVALUATION 2010.pdf

PDF 79 KB Posted

Attached to
Z1DA--578-21-028 Replace Building 48 Roof System (VA-21-00077419)
Solicitation number
36C25221B0025
Issued by

About this file

This document package includes an ACM reevaluation report for Building 48 and a pre-solicitation notice for replacing the roof system. The ACM reevaluation report details the location, material type, quantity, condition, and test results of asbestos-containing materials throughout rooms in Building 48. The pre-solicitation notice is for project number 578-21-028 to replace the roof of Building 48 at the Edward Hines, Jr. VA Hospital. The objectives are to remove existing exhaust fans and skylights, the coal tar roof assembly, and install a new roof assembly. The period of performance is 120 calendar days from notice to proceed. The solicitation will be issued on July 16, 2021 with bid opening on August 17, 2021. The requirement value is between $500,000 and $1 million. The NAICS code is 238160 and it is set aside for SDVOSBs.

View the file

Other files

File Type Posted
36C25221B0025 0003.docx DOCX document
S06 - Att 01 - Wage Determination 08_13_2021.pdf PDF
36C25221B0025 0002.docx DOCX document
S06 - Att 02 - 22 14 00.pdf PDF
S06 - Att 01 - Wage Determination 07_30_2021.pdf PDF
S06 - Att 01 - STC-028211.pdf PDF
36C25221B0025 0001.docx DOCX document
S06 - Att 02 - Inspection Summary Report Bldg 48 - 2010.pdf PDF
14) No Smoking Policy 10-1-19.pdf PDF
16) Hines COVID-19 Guidelines.pdf PDF
1) Hines VA Campus Site Plan.pdf PDF
SOW 578-21-028 Replace Building 48 Roof System.pdf PDF
17) Drawing Specifications 578-21-028.pdf PDF
11) Contractor Parking.pdf PDF
4) Safety and Health During Construction Activities.pdf PDF
10) Contractor PIV Instructions and Form.pdf PDF
6) Above Ceiling Entry and Wall Construction Permits.pdf PDF
15) Infection Control Barrier Sample.pdf PDF
P07 Wage Determination.txt TXT text file
Wage Determination 7-14-2021.pdf PDF
12) OIT Horizontal Cable Requirements.pdf PDF
36C25221B0025.docx DOCX document
3) Pre-Construction Checklist.pdf PDF
2) Hines Underground Utility Plan.pdf PDF
13) Specifications Book.pdf PDF
18) Pre-Existing Site Photos.pdf PDF
8) Interim Life Safety Measures (ILSM).pdf PDF
5) Cutting Welding and Other Hot Work.pdf PDF
7) Pre-Construction Risk Assessment (PCRA).pdf PDF
9) Infection Control Risk Assessment (ICRA).pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MC Consulting Inc. Building 48

LOCATION ACM % TYPE QTY SAMPLE MATERIAL DESCRIPTION REEVALUATION 2010 COMMENTS

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

AREA 1ST FLOOR

ROOM 101

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

VFT 0 NA 16 SF 97744-X 1'X1' BLU W/WHT STRKS N GOOD MOD NO CHANGE

VFT 0 NA 455 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 16 SF 97744-X MSTC FOR 97744 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 455 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM 102

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 33 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

VFT 0 NA 650 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 33 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 650 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

ROOM 103

ACT 0 NA 134 SF 97693-X 2'X4' WHT PEBBLE Y GOOD LOW NO CHANGE

ACT 0 NA 390 SF 97694-X PN Y GOOD LOW NO CHANGE

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 46 SF 97691-X 6" BLK BSBRD N GOOD LOW NO CHANGE

VFT 0 NA 529 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 46 SF 97691-X MSTC FOR 97691 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 529 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

1 PIPE-STM 50 MIX 4 LF 97749- STM INS IN WALL AROUND PIPE Y GOOD LOW NO CHANGE

ROOM 104

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 35 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

VFT 0 NA 492 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 35 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 492 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM 105

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 21 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

7 VFT 2 CHR 255 SF 97748-X 1'X1' WHT W/GRN & GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 21 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

7 MSTC 20 CHR 255 SF 97748-X MSTC FOR 97748 LAB RESULT N GOOD LOW NO CHANGE

ROOM 106

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 20 SF 97687-X 4" BLK BSBRD GOOD LOW NO CHANGE

VFT 2 CHR 216 SF 97748-X 1'X1' WHT W/GRN & GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 20 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

7 MSTC 20 CHR 216 SF 97748-X MSTC FOR 97748 LAB RESULT N GOOD LOW NO CHANGE

ROOM 107

ACT 0 NA 96 SF 97693-X 2'X4' WHT PEBBLE Y GOOD LOW NO CHANGE

ACT 0 NA 142 SF 97694-X PN Y GOOD LOW NO CHANGE

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 30 SF 97691-X 6" BLK BSBRD N GOOD LOW NO CHANGE

VFT 0 NA 230 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 20 SF 97691-X MSTC FOR 97691 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 230 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

1 PIPE-STM 50 MIX 4 LF 97749-X STM INS IN WALL AROUND PIPE Y POOR LOW NO CHANGE

ROOM 107A

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 9 SF 97691-X 6" BLK BSBRD N GOOD LOW NO CHANGE

VFT 0 NA 20 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 6 SF 97691-X MSTC FOR 97691 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 20 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

ROOM 108

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

VFT 0 NA 432 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 25 SF 97691-X MSTC FOR 97691 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 432 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

ACT 0 NA 168 SF 97693- 2'X4' WHT PEBBLE Y GOOD LOW NO CHANGE

ACT 0 NA 168 SF 97694- PN Y GOOD LOW NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

PLAS-W 0 NA 1216 SF 97692- PLAS Y GOOD MOD NO CHANGE

BSBRD 0 NA 38 SF 97691- 6" BLK BSBRD N GOOD LOW NO CHANGE

ROOM 109

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 16 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 NA 16 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

7 MSTC 20 CHR 140 SF 97748-X MSTC FOR 97748 LAB RESULT N GOOD LOW NO CHANGE

7 VFT 2 CHR 140 SF 97748- 1'X1' WHT W/GRN & GRY STRKS N GOOD MOD NO CHANGE

ROOM 110

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM 111

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM 112

ACT 0 NA 1800 SF 97694-X PN Y GOOD LOW NO CHANGE

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 166 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

VFT 0 NA 1000 SF 97744-X 1'X1' BLU W/WHT STRKS N GOOD MOD NO CHANGE

VFT 0 NA SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 166 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 1000 SF 97744-X MSTC FOR 97744 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

DUCT NA NA NA NA DUCT INS NS NA NA NA NO CHANGE

ROOM 113

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 30 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

MSTC 0 NA 30 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

7 MSTC 20 CHR 238 SF 97747-X MSTC FOR 97747 LAB RESULT N GOOD LOW NO CHANGE

VFT <1 CHR 238 SF 97747- 1'X1' BRN W/LT & DK BRN FLKS N GOOD MOD NO CHANGE

ROOM 114

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 15 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 NA 15 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

7 MSTC 20 CHR 112 SF 97746-X MSTC FOR 97746 LAB RESULT N GOOD LOW NO CHANGE

VFT <1 CHR 112 SF 97746- 1'X1' BRN W/GRY & WHT FLKS N GOOD MOD NO CHANGE

ROOM 115

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 93 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

VFT 0 NA 200 SF 97744-X 1'X1' BLU W/WHT STRKS N GOOD MOD NO CHANGE

VFT 0 NA 4500 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 93 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 200 SF 97744-X MSTC FOR 97744 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 4500 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

ROOM 116

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 30 SF 97689-X 4" BRN BSBRD GOOD LOW NO CHANGE

VFT 0 NA 238 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

MSTC 0 NA 30 SF 97689-X MSTC FOR 97689 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 238 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

ROOM 116A

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

MSTC 0 NA 7 SF 97689-X MSTC FOR 97689 LAB RESULT N GOOD LOW NO CHANGE

WALL-BRD 0 NA 140 SF 97690- WALL-BRD Y GOOD MOD NO CHANGE

BSBRD 0 NA 7 SF 97689- 4" BRN BSBRO N GOOD LOW NO CHANGE

VFT 0 NA 24 SF 97745- 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

ROOM 117

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

VFT NA NA 850 SF 97745-X 1'X1' WHT W/GRY STRKS N GOOD MOD NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

MSTC 0 NA 850 SF 97745-X MSTC FOR 97745 LAB RESULT N GOOD LOW NO CHANGE

ROOM 118

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM 119

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM SW1

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

7 PIPE-COND 50 50 MIX 10 LF 97749-X N-ACC COND Y GOOD LOW NO CHANGE

1 PIPE-STM 50 MIX 10 LF 97749-X STM INS IN WALL AROUND PIPE Y GOOD LOW NO CHANGE

7 PIPE F-CON 50 MIX 1 EA 97749-X N-ACC COND Y GOOD LOW Presume behind walls & above ceilings 7 PIPE F-STM 50 MIX 1 EA 97749-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM SW2

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 NA 8 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 NA 8 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 40 SF 97744-X MSTC FOR 97744 LAB RESULT N GOOD LOW NO CHANGE

VFT 0 NA 40 SF 97744- 1'X1' BLU W/WHT STRKS N GOOD MOD NO CHANGE

AREA 2ND FLOOR

ROOM 201

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

BSBRD 0 17 SF 97687-X 4" BLK BSBRD N GOOD LOW NO CHANGE

7 MSTC 20 CHR 144 SF 97686-X MSTC FOR 97686 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 17 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

7 VFT 10 CHR 144 SF 97686- 9"X9" WHT W/YEL & GRN STRKS N GOOD MOD NO CHANGE

ROOM 202

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

7 VFT 10 CHR 56 SF 97686-X 9"X9" WHT W/YEL & GRN STRKS N GOOD MOD NO CHANGE

7 MSTC 20 CHR 56 SF 97686-X MSTC FOR 97686 LAB RESULT N GOOD LOW NO CHANGE

MSTC 0 NA 10 SF 97687-X MSTC FOR 97687 LAB RESULT N GOOD LOW NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

BSBRD 0 NA 10 SF 97687- 4" BLK BSBRD N GOOD LOW NO CHANGE

ROOM 203

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM 204

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

ROOM 205

NSCM NA NA NA NA NSCM NA NA NA NO CHANGE

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

AREA CRAWL SPACE

ROOM CRWL

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSINS NA NA NA NA NSINS NA NA NA NO CHANGE

OTHR <1 CHR 40000 SF 97743- OTHR NA FAIR LOW NO CHANGE

AREA ROOF

ROOM RMCI

NSWM NA NA NA NA NSWM NA NA NA NO CHANGE

NSFM NA NA NA NA NSFM NA NA NA NO CHANGE

VIB 0 NA 10 SF 97688- VIB N GOOD LOW NO CHANGE

ROOM ROOF

7 RFNG 30 CHR 10000 SF 97684- ROOFING TAR N GOOD LOW NO CHANGE

7 RFNG 25 CHR 40000 SF 97685- FELT N GOOD LOW NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST