S06 - A-601_Addendum 1.pdf
PDF 325 KB Posted
- Attached to
- Z1DA--537-19-101 Taylor Elevator Modernization Federal contract opportunity
- Solicitation number
- 36C25220R0063
About this file
This document package includes construction plans and specifications for the modernization of elevators at the Jesse Brown VA Medical Center in Chicago, Illinois. The project involves upgrading existing passenger and service elevators, including replacing elevator equipment, controls, interior cab finishes and components. New materials will include stainless steel wall and ceiling panels, tile flooring, signage, lighting and crash rails. The construction documents provide existing conditions drawings, demolition plans, specifications for new materials and finishes, and notes. Additionally, the related federal contract opportunity is solicitation number 36C25220R0063 for the Taylor Elevator Modernization project at the Jesse Brown VA Medical Center under the Department of Veterans Affairs Veterans Health Administration VISN 12. The estimated period of performance includes a May 18, 2020 issue date for bid and construction.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25220R0063_8.docx | DOCX document | |
| 36C25220R0063 0003.docx | DOCX document | |
| S06 - Specs 000115 List of Drawings.pdf | ||
| 36C25220R0063_7.docx | DOCX document | |
| S06 - Addendum1.pdf | ||
| S06 - Specs 024119 SelectiveDemolition.pdf | ||
| S06 - FA-001 Addendum 1.pdf | ||
| S06 - Specs 014500 QualityControl.pdf | ||
| S06 - A-402_Addendum 1.pdf | ||
| S06 - Consolidated RFI Response 537-19-101.pdf | ||
| S06 - Specs 000110 TOC 18-401.pdf | ||
| 36C25220R0063_6.docx | DOCX document | |
| 36C25220R0063-068.pdf | ||
| 36C25220R0063-067.docx | DOCX document | |
| 36C25220R0063-066.pdf | ||
| 36C25220R0063-060.pdf | ||
| 36C25220R0063-059.docx | DOCX document | |
| 36C25220R0063-064.pdf | ||
| 36C25220R0063-062.pdf | ||
| 36C25220R0063-061.pdf | ||
| 36C25220R0063-063.pdf | ||
| 36C25220R0063-065.pdf |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PT3
PT4
ST1
PT1
PT2
HALLWAY
LOBBY
NOT IN
OPERATION
FREIGHT
CURRENTLY
MT3 MT3
MT3MT3
WARNING
ALL ACCIDENTS ON OR DAMAGE TO ELEVATORS
ARE TO BE REPORTED TO THE DEPARTMENT
OF CONSUMER AND REGULATORY AFFAIRS
(???) ???-????; OR AFTER WORKING HOURS
BY CALLING (???)
ELEVATORS SHALL NOT BE USED
IN CASE OF
ELEVATOR ???
CAPACITY 3500 LBS
IN MANAGEMENT OFFICE.
ELEVATOR CERTIFICATE IS LOCATED
FIRE OR ELECTRICAL EMERGENCY
USE DESIGNATED EXITS
EMERGENCY CALL CANCEL
FIREFIGHTERS'
OPEN CLOSE
OPERATION
PUSH TO CALL
FIREFIGHTERS'
TELEPHONE
G R
AI
N
G R
AI
N
NO SMOKING
FIRE OPERATION
2 3
4 5 6
1 2 3
4 5 6
MEDICAL EMERGENCY OPERATION
1. INSERT KEY
2. TURN TO ON POSITION
3. AFTER REGISTRATION OF CALL
TURN KEY "OFF" AND REMOVE
OFF ONOFF ON
PUSH
TO CALL
NO SMOKING
PUSH
TO CALL
B2
S
S1
T1
B1
MT3 MT3 MT3
MT3
MT3
O
O O
WARNING
ALL ACCIDENTS ON OR DAMAGE TO ELEVATORS
ARE TO BE REPORTED TO THE DEPARTMENT
OF CONSUMER AND REGULATORY AFFAIRS
(???) ???-????; OR AFTER WORKING HOURS
BY CALLING (???)
ELEVATORS SHALL NOT BE USED
IN CASE OF
ELEVATOR ???
CAPACITY 3500 LBS
IN MANAGEMENT OFFICE.
ELEVATOR CERTIFICATE IS LOCATED
FIRE OR ELECTRICAL EMERGENCY
USE DESIGNATED EXITS
EMERGENCYCALL CANCEL
G R
AI
N
G R
AI
N
NO SMOKING
FIRE OPERATION
MEDICAL EMERGENCY OPERATION
1. INSERT KEY
2. TURN TO ON POSITION
3. AFTER REGISTRATION OF CALL
TURN KEY "OFF" AND REMOVE
OFFON OFFON
PUSH
TO CALL
S
B2
B1
B
T
S
S
S
T
B1
BMT3 MT3
MT3MT3
WARNING
ALL ACCIDENTS ON OR DAMAGE TO ELEVATORS
ARE TO BE REPORTED TO THE DEPARTMENT
OF CONSUMER AND REGULATORY AFFAIRS
(???) ???-????; OR AFTER WORKING HOURS
BY CALLING (???)
ELEVATORS SHALL NOT BE USED
IN CASE OF
ELEVATOR ???
CAPACITY 3500 LBS
IN MANAGEMENT OFFICE.
ELEVATOR CERTIFICATE IS LOCATED
FIRE OR ELECTRICAL EMERGENCY
USE DESIGNATED EXITS
EMERGENCY CALL CANCEL
FIREFIGHTERS'
OPEN CLOSE
OPERATION
PUSH TO CALL
FIREFIGHTERS'
TELEPHONE
G R
AI
N
G R
AI
N
NO SMOKING
FIRE OPERATION
2 3
4 5 6
1 2 3
4 5 6
MEDICAL EMERGENCY OPERATION
1. INSERT KEY
2. TURN TO ON POSITION
3. AFTER REGISTRATION OF CALL
TURN KEY "OFF" AND REMOVE
OFF ONOFF ON
PUSH
TO CALL
NO SMOKING
GL4 MCCORY LAMINATED GLASS BACKPAINTED
TO MATCH F&S VIVID GLASS IN WHITE
OPALEX
MT2 CAMBRIDGE ST. STL MESH IN 880'S BEAD
PATTERN
MT3 #4 SATIN FINISH STAINLESS STEEL
A EXISTING CAB TO REMAIN. MODIFY AS
REQUIRED FOR NEW FINISHES
MATERIALS & FINISHES
LEGEND
WALLS
B GLASS PANEL - 1_
2" THICK F.R. WOOD
SUBSTRATE FACED WITH GL4 AND FRAMED
WITH MT3's J BINDERS
B1 MESH PANEL - DECORATIVE STAINLESS
STEEL MESH PATTERN "5WL" FROM
RIGIDIZED METALS CORP.
C REVEAL - MT3 APPLIED DIRECTLY TO SHELL
D BASE - FORMED MT3 CLAD TO BLOCKING TO
ALIGN WITH PANELS.
DOORS
J CAB DOORS - PROVIDE NEW INTERIOR AND
EXTERIOR DOORS WITH NO. 4 STAINLESS
STEEL "SATIN" FINISH.
CEILING
K CANOPY - EXISTING CANOPY TO REMAIN /
VISIBLE AREAS PAINTED BLACK.
L SUSPENDED CEILING - 3_
4" F.R. WOOD
SUBSTRATE HAS (6) PANELS WITH NO 4.
STAINLESS STEEL - MIST FINISH SECURED
TO IT. EACH WITH DOWNLIGHT CENTERED
IN IT.
LIGHTING
M LIGHTS - (6) TECH LIGHTING ELEMENT LED
RECESSED DOWNLIGHTS W/ CIRCULAR
MATCHING BEZEL.
N EMERGENCY LIGHTS - MAN-TEC-ELS-500
FRONTS
HANDRAILS
R HANDRAILS - (2) 1" X 3" FLAT BUMPER TYPE,
WITH CURVED ENDS IN SATIN FINISH.
R1 CRASH RAIL - (1) 1" X 3" FLAT BUMPER TYPE,
WITH CURVED ENDS IN SATIN FINISH
* HANDRAIL DESIGN SHALL MEET ACCESSIBILITY
REQUIREMENTS OF THE VA BARRIER FREE DESIGN
STANDARD - PG-18-13, AND ALL APPLICABLE SPECIAL
ACCOMMODATION REQUIREMENTS PER VA DESIGN
MANUAL
B2 1_
2" THICK F.R. WOOD SUBSTRATE FACED
WITH STAINLESS STEEL SHEET WITH A
"LINEN" FINISH BY FORMS+SURFACES.
O FRONTS - CLAD EXISTING STATIONARY
RETURN, SWING OUT PANEL AND TRANSOM
WITH 14 GA, #4 STAINLESS STEEL "SATIN"
FINISH.
FLOOR
T FLOOR - (PASSENGER) 12"x12" SOLID VINYL
TILE WITH 2 COLORS (SELECTED BY
OWNER,) ROTATE 45° WITH ACCENT
SQUARE.
T1 FLOOR - (SERVICE) MONOLITHIC RESINOUS
FLOORING . COLOR - DARK GRAY.
S HANDRAILS - (2) 1" X 3" FLAT BUMPER TYPE,
WITH CURVED ENDS IN SATIN FINISH.
S1 CRASH RAIL - (1) 1" X 6" FLAT BUMPER TYPE,
WITH CURVED ENDS IN SATIN FINISH
SERVICE ELEVATOR
7'-7 1/2"
8' -6
4' -2
3'
-1 0"
4'-7"
8' -6
3' -1
0" 4'
-2
3'-10"
7' -0
1'-11"
DEMOLISH EXISTING CEILING & LIGHTS
DEMOLISH EXISTING LAMINATE WALL PANEL
DEMOLISH EXISTING S.S. WALL PANEL
DEMOLISH EXISTING S.S. BUMPER GUARDS
DEMOLISH EXISTING FLOORING
DEMOLISH EXISTING CEILING & LIGHTS
DEMOLISH EXISTING LAMINATE WALL PANEL
DEMOLISH EXISTING S.S. WALL PANEL
DEMOLISH EXISTING S.S. BUMPER GUARDS
DEMOLISH EXISTING FLOORING
DEMOLISH EXISTING CEILING & LIGHTS
DEMOLISH EXISTING LIGHT COVE
DEMOLISH EXISTING S.S. WALL PANEL
DEMOLISH EXISTING S.S. BUMPER GUARDS
DEMOLISH EXISTING FLOORING
DEMOLISH EXISTING LAMINATE WALL PANEL
DEMOLISH EXISTING LIGHT COVE
DEMOLISH EXISTING ELEVATOR
EQUIPMENT & CONTROLS
A-6011-C
1-B
1-A
1D1-D
/2
/2
/2
NEW 2' X 2' STAINLESS
STEEL CEILING WITH
LED LIGHTING
TYPICAL STAINLESS
STEEL 4" TALL CRASH
RAIL (TYPICAL SIDES
AND REAR WALL)
NEW ELEVATOR
CALL BUTTON
NEW SIGNAGE
NEW STAINLESS
STEEL WALL PANELS
/2
/2
/2
7'-7 1/2" +/-
6"
1/ 2"
3"
1/ 2"
3"
/2
7'-11" +/-
EQ
U
AL
P
AN
EL
S
/2
EQ
U
AL
P
AN
EL
S
/2
7'-1 1/2" +/-
7' -1
0" T
O
'-0
4'-1" +/-
Scale: 3/4" = 1'-0"
1 EXISTING ELEVATOR DEMOLITION
Scale: 1/4" = 1'-0"
2 EXISTING PLAN-TYPICAL
A B C D
Engineers Architects Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
MICHAEL BLADES & ASSOCIATES, CTO-ELEVATOR CONSULTANTS
5/
/2
2:
:5
PM
A-601
EXISTING PLAN AND ELEVATION
11 12ANP
ELEVATOR MODERNIZATION
JESSE BROWN VA MEDICAL CENTER
820 S. DAMEN AVENUE
CHICAGO, ILLINOIS 60612 02/12/2020
ISSUED FOR BID AND CONSTRUCTION
537-19-101A18-401
11A
JAB
(APPLIES TO ALL ELEVATORS)
Scale: 3/4" = 1'-0"
6 PASSENGER ELEVATOR SECTION
Scale: 3/4" = 1'-0"
5 SERVICE ELEVATOR-INTERIOR DOOR ELEVATION
Scale: 3/4" = 1'-0"
4 SERVICE ELEVATOR-INTERIOR SIDE WALL ELEVATION
Scale: 3/4" = 1'-0"
3 SERVICE ELEVATOR-INTERIOR REAR WALL ELEVATION
Scale: 3/4" = 1'-0"
7 PASSENGER ELEVATOR-INTERIOR REAR WALL ELEVATION
Scale: 3/4" = 1'-0"
8 PASSENGER ELEVATOR-INTERIOR SIDE WALL ELEVATION
Scale: 3/4" = 1'-0"
9 PASSENGER ELEVATOR-INTERIOR DOOR ELEVATION
1 ADDENDUM 01 05/18/2020
ELEVATOR MANUFACTURER TO SUBMIT FINAL SHOP
DRAWINGS FOR THE INTERIOR ELEVATOR CAB DESIGN. SHOP
DRAWINGS SHALL HAVE ALL MATERIALS INCLUDED.
DocuSign Envelope ID: F8F2DD30-7B07-45A6-904A-26CCDE5344AA
5/18/2020
| Sheets |
| A-601 - EXISTING PLAN AND ELEVATION |
| 2020-05-18T13:33:43-0700 | |
| Digitally verifiable PDF exported from www.docusign.com |
File details come from the government source that posted it. Updated .