This document package includes plans and specifications for an elevator modernization project at the Jesse Brown VA Medical Center in Chicago, Illinois. The project involves replacing controls, motors, cabling, and exit doors for four passenger elevators and one service elevator serving nine floors. Elevator cabs will be renovated with new finishes, ceilings, lighting, flooring, and wall panels. Exterior doors and controls in the lobbies will be replaced in the existing locations. The sixth and seventh floor lobbies can be used for temporary storage and staging during construction. The machine room floor will be painted once old equipment is removed in phases corresponding to elevator refurbishment. An opening from a demolished mechanical exhaust vent must be closed on the roof along with roof repairs and replacement of the entire elevator machine room roof section to match the existing roof system. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 12 for proposal number 537-19-101 Taylor Elevator Modernization.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25220R0063_8.docx | DOCX document | |
| 36C25220R0063 0003.docx | DOCX document | |
| S06 - A-601_Addendum 1.pdf | ||
| S06 - Specs 000115 List of Drawings.pdf | ||
| 36C25220R0063_7.docx | DOCX document | |
| S06 - Addendum1.pdf | ||
| S06 - Specs 024119 SelectiveDemolition.pdf | ||
| S06 - Consolidated RFI Response 537-19-101.pdf | ||
| S06 - Specs 000110 TOC 18-401.pdf | ||
| S06 - FA-001 Addendum 1.pdf | ||
| S06 - Specs 014500 QualityControl.pdf | ||
| 36C25220R0063_6.docx | DOCX document | |
| 36C25220R0063-067.docx | DOCX document | |
| 36C25220R0063-068.pdf | ||
| 36C25220R0063-064.pdf | ||
| 36C25220R0063-062.pdf | ||
| 36C25220R0063-066.pdf | ||
| 36C25220R0063-061.pdf | ||
| 36C25220R0063-063.pdf | ||
| 36C25220R0063-065.pdf | ||
| 36C25220R0063-060.pdf | ||
| 36C25220R0063-059.docx | DOCX document |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL
62E2
ELEVATOR LOBBY
C6204
ELEVATOR
PT2
ELEVATOR
ELEVATOR
ST1
ELEVATOR
PT3
ELEVATOR
PT4
STAIR
NO-11
PT1
TEL
62T1
ELEVATOR
72T1
ELEVATOR
PT2
ELEVATOR
PT1
ELEVATOR
ST1
CORRIDOR
C7201
ELEVATOR
PT3
PT4
STAIR
NO 11
ELECTRICAL
72E2
TELECOM CLOSET
ELEVATOR
PT2
ELEVATOR
PT1
ELEVATOR
ST1
ELEVATOR
PT4
ELEVATOR
PT3
STAIR
NO-11
STAIR
NO 11
FIN. 1ST FLOOR
FIN. 2ND FLOOR
FIN. 3RD FLOOR
1 _ 4
1 _ 2
1 _ 2
FIN. 4TH FLOOR
FIN. 5TH FLOOR
FIN. 6TH FLOOR
FIN. 7TH FLOOR
1 _ 2
1 _ 2
1 _ 2
PASSENGER ELEV. (4)
9 FLOORS - 7 STOPS
PT1, PT2, PT3, PT4
SERVICE ELEV. (1)
9 FLOORS - 7 STOPS
ST1
FIN. 8TH FLOOR
FIN. MACHINE ROOM FLOOR
1 _ 2
1 _ 4
L.P. OF ROOF SLAB
FIN. GROUND FLOOR
TEMPORARY STORAGE
AND LAY DOWN AREA
TEMPORARY STORAGE
AND LAY DOWN AREA
ROOF ACCESS DOOR
ST1
PT1PT4
PT3 PT2
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
JE
FFREY A BROOKS
11296R
EG
IS
TERED ARCHITECT
N O
R
T H
C A R O L
I N
ARA
LE
IGH , NORT H CAROL
I N
A
Engineers Architects
## KEY NOTES:
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
MICHAEL BLADES & ASSOCIATES, CTO-ELEVATOR CONSULTANTS
/1
/2
:4
:5
P
M
A-402
ENLARGED EXISTING FLOOR PLANS &
ELEVATOR RISER DIAGRAM
10 12ANP
ELEVATOR MODERNIZATION
JESSE BROWN VA MEDICAL CENTER
820 S. DAMEN AVENUE
CHICAGO, ILLINOIS 60612 02/12/2020
ISSUED FOR BID AND CONSTRUCTION
537-19-101A18-401
11A
JAB
0 2 4 8
N O
R T
H
PLAN
0 2 4 8
N O
R T
H
PLAN
0 2 4 8
N O
R T
H
PLAN
0 2 4 8
N O
R T
H
PLAN
Scale: 1/4" = 1'-0"
ENLARGED EXISTING SIXTH FLOOR PLAN
Scale: 1/4" = 1'-0"
ENLARGED EXISTING SEVENTH FLOOR PLAN
Scale: 1/4" = 1'-0"
ENLARGED EXISTING EIGHTH FLOOR PLAN
Scale: 1/4" = 1'-0"
ENLARGED EXISTING MACHINE ROOM FLOOR PLAN
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
W T
A Y
L O
R S
T R
E E
T
01 NOT USED.
02 SEE ELECTRICAL DWGS. FOR NEW SHAFT
LIGHTING.
03 THE EXISTING ELEVATORS CONTROLS,
MOTORS, CABLEING AND EXIT DOORS WILL BE
REPLACED FOR EACH CAR. EACH ELEVATOR
CAB WILL BE RENOVATED WITH NEW FINISHES,
NEW CEILING AND LIGHTING, NEW FLOORING,
AND NEW WALL PANELS AND RAILS AS
DETAILED ON SHT. A-601
04 INSTALL NEW EXTERIOR DOORS AND CONTROLS
IN THE LOBBIES AS SPECIFIED IN THE SAME
LOCATION AS EXISTING DOORS AND CONTROLS.
05 CLOSE UP EXISTING ELEVATOR DOOR
WITH NEW 2 HOUR WALL ASSEMBLY. 2X6
18 GA METAL WALL STUDS @ 16 O.C., (2)
LAYERS OF 5/8" TYPE "X" GYPSUM BOARD ON
BOTH SIDES OF WALL. FIRE CAULK ALL JOINTS
AND PENETRATIONS FOR A 2 HOUR RATED
ASSEMBLY. TURN ELEVATOR DOORS OVER TO
THE COR FOR PROPER DISPOSAL.
06 PAINT EXISTING MACHINE ROOM FLOORS ONCE
OLD EQUIPMENT HAS BEEN REMOVED. PAINTING
SHALL TAKE PLACE IN DIFFERENT PHASES AS
EACH ELEVATOR IS BEING REFURBISHED.
07 A PORTION OF THE 6TH AND 7TH FLOOR LOBBY
SPACE CAN BE UTILIZED FOR STORAGE AND A
STAGING AREA. THE GC SHALL ENCLOSE THE
AREA WITH TEMPORARY RIGID WALLS MEETING
THE INFECTION CONTROL REQUIREMENTS.
PLEASE SEE FLOOR PLAN FOR LIMITS OF
ENCLOSED AREAS
08 CONTRACTOR SHALL CLOSE UP OPENING FROM
DEMOLISHED MECHANICAL EXHAUST VENT.
CONTRACTOR SHALL INCLUDE REROOFING THE
ENTIRE ELEVATOR MACHINE ROOM SPACE.
COORDINATE LOCATION WITH MECHANICAL
DRAWINGS AND FINAL ROOFING INFORMATION
WITH COR.
DOOR SCHEDULE
DOOR DOOR FRAME FIRE
RATING
HDWR
SET REMARKSNO. WIDTH HEIGHT THICK MAT'L FINISH MAT'L FINISH
MACHINE ROOM FLOOR PLAN
901 3' - 6" 6' - 8" 1 3/4" 90MIN. REPLACE EXISTING DOOR WITH 900MIN FIRE RATED DOOR
AND 2HR RATED FRAME. VERIFY SIZE IN FIELD.
HM PT HM PT
Scale: No Scale
ELEVATOR RISER DIAGRAM
DocuSign Envelope ID: DB6390C2-326C-4F6F-95FC-61D9C19491B1
2/12/2020
CONTRACTOR SHALL CLOSE UP ROOF OPENING
FROM DEMOLISHED MECHANICAL EXHAUST
VENT. ROOF REPAIR WILL INCLUDE NEW
CONCRETE ROOF STRUCTURE, AND THE NEW
ROOF SYSTEM WILL BE PATCHED TO MATCH THE
EXISTING ROOF SYSTEM THAT IS CURRENTLY IN
PLACE.
1 ADDENDUM 01 05/18/2020
5/18/2020