This document contains an asbestos testing report and federal contract opportunity notice for replacing existing roofing at the Jesse Brown VA Medical Center in Chicago, Illinois. Asbestos testing identified non-friable asbestos-containing materials in the flashing of Roof Areas 6 and 7 of Building 30, totaling 370 linear feet. The contract opportunity is to provide all labor, materials, equipment and supervision to demolish existing roofing and install new roofing systems on Buildings 1, 11A, 15, 21 and 30. The project value is estimated between $1-2 million. The solicitation number is 36C25220B0008 and will be posted to FedBizOpps on November 12, 2019 with a bid opening of December 12, 2019. A pre-bid conference will be held to review the drawings and specifications included with the solicitation. The North American Industry Classification for this requirement is 238160 for Roofing Contractors. The period of performance for the base bid is 240 calendar days from notice to proceed.

36C25220B0008 0003 S06 - Asbestos Survey 537-15-128B - April 2019.pdf

View the file

Other files

File Type Posted
36C25220B0008-0005001.pdf PDF
36C25220B0008-0005000.docx DOCX document
36C25220B0008-0004000.docx DOCX document
36C25220B0008-0004001.pdf PDF
36C25220B0008-0003001.pdf PDF
36C25220B0008-0003002.pdf PDF
36C25220B0008-0003000.docx DOCX document
36C25220B0008-0002004.docx DOCX document
36C25220B0008-0002005.pdf PDF
36C25220B0008-0001000.docx DOCX document
36C25220B0008-0001001.pdf PDF
36C25220B0008-0001002.pdf PDF
36C25220B0008-010.pdf PDF
36C25220B0008-005.docx DOCX document
36C25220B0008-011.pdf PDF
36C25220B0008-008.pdf PDF
36C25220B0008-007.pdf PDF
36C25220B0008-006.pdf PDF
36C25220B0008-009.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS TESTING REPORT

JESSE BROWN VA MEDICAL CENTER

REPLACE EXISTING ROOF

PROJECT 537-15-128B

Date: April 25, 2019

Items: Summary Results of Asbestos Survey, Visual Inspection, Lab Results

Inspector: Brett Brumbaugh, Castle Hill Associates

Findings: Asbestos present in flashings of roof areas 6 and 7 of Building 30 as follows:

BUILDING 30 – ROOF AREA 6

ASBESTOS CONTAINING MATERIAL QUANTITY LOCATIONS

Flashing tar under rubber roof (Category 1 Non-Friable)

168 LF of flashing Flashings at edge of roof, vent, and roof access hatch

BUILDING 30 – ROOF AREA 7

ASBESTOS CONTAINING MATERIAL QUANTITY LOCATIONS

Flashing tar under rubber roof (Category 1 Non-Friable)

202 LF of flashing Flashings at edge of roof, vent, and roof access hatch

ASBESTOS ABATEMENT COST ESTIMATE

REPLACE EXISTING ROOF

Estimator: Brett Brumbaugh

Notes: Based on 2019/20 construction and bidding

EXCLUDES:

• Overtime or shift work.

INCLUDES:

• Bonds, insurance, contractor overhead and profit

• Prevailing wage rates for Chicago, IL

Cost Index: Chicago, IL

Description HazMat Material/Task Quantity Unit Cost Amount

Roof area 6

02 82 11 OSHA CPIH air monitoring during tearoff 1 1400.00 $1,400.00

Roof area 7

02 82 11 OSHA CPIH air monitoring during tearoff 1 1400.00 $1,400.00

Total HazMat Costs $2,800.00

ASBESTOS SAMPLING REPORT

LOCATION:

820 S. DAMEN AVE.

CHICAGO, IL 60612

PROJECT:

REPLACE ROOFING PROJECT

10 ROOF AREAS

BUILDINGS 1A, 11A, 15, 21, AND 30

VA PROJECT: 537-15-128B

SAMPLING DATE:

APRIL 17, 2019

CONSULTANT:

CASTLE HILL ASSOCIATES, LLC

218-A MECHANIC ST.

WATERVILLE, OH 43566

567-952-0212 www.CASTLEHILLASSOCIATES.com http://www.castlehillassociates.com/

TABLE OF CONTENTS

• ASBESTOS SAMPLING SUMMARY

• ABESTOS BULK SAMPLING DESCRIPTIONS AND LAB RESULTS

• ASBESTOS LABORATORY REPORT

• ASBESTOS LABORATORY CERTIFICATIONS

• INSPECTOR CERTIFICATIONS

CHICAGO, IL

REPLACE EXISTING ROOFS

ASBESTOS INSPECTION SUMMARY

On April 17, 2019, Brett Brumbaugh performed asbestos testing at the Jesse Brown VA Medical Center in Chicago, IL in preparation of the roof replacement project. The roof areas included in the sampling were:

As part of this survey, a total of 62 sample layers were collected from 10 roof areas. All samples collected during the inspection were analyzed by the EPA 600/R-93/116 Method using Polarized Light Microscopy at a NVLAP accredited laboratory (EMLab P&K). Many of the samples of suspect asbestos containing materials that were analyzed had no asbestos detected. A negative sample analysis is the only definitive method to determine if a material can be considered “non-asbestos” in accordance with OSHA and EPA regulations.

Bulk sampling as part of this project was based upon the appearance, texture, and location of the suspect materials. All bulk samples were analyzed utilizing current EPA methods for PLM (Polarized Light Microscopy) by EMLab/P&K in Marlton, NJ. This lab is accredited by the NIST, NVLAP program (National Institute of Standards and Technology, National Voluntary Laboratory Accreditation Program) and also an American Industrial Hygiene Association (AIHA) accredited laboratory.

ASBESTOS INSPECTION FINDINGS

As a result of this inspection, current sampling, and previous surveys/sampling, it has been determined that non-friable, Category 1 asbestos containing materials are present in the tar flashings under the rubber roofs of Roof Areas 6 and 7 of Building 30.

Asbestos containing materials were identified in the roofing areas scheduled for replacement as follows:

Building 30 – Roof Areas 6 and 7

ASBESTOS CONTAINING MATERIAL QUANTITY EPA CATEGORY ASSESSMENT

Flashing tar under rubber roof at edge of roofs, vents, and access hatches

370 LF of flashing Cat. 1 Non-Friable

CONCLUSIONS/RECOMMENDATIONS

The asbestos containing materials identified in the roof flashings must be handled in accordance with current OSHA, US EPA, and State of Illinois asbestos regulations. All asbestos materials must be handled by trained workers, but do not have to be removed by an Illinois licensed Asbestos Contractor since they are assessed to be Category 1 Non-Friable asbestos materials in good condition.

Respectfully Submitted:

Inspector/Project Manager State of Illinois Asbestos Inspector License # 100-09972

ROOF AREAS IN SCOPE OF WORK

Roof areas with asbestos flashings

ASBESTOS BULK SAMPLE DESCRIPTIONS & RESULTS

Facility: Jesse Brown VA Medical Center – Chicago, IL Project: 537-15-128B – Replace Existing Roofs Sampling Date: April 17, 2019 Analysis Dates: April 23-24, 2019 Sampler: Brett Brumbaugh Laboratory: EMLab P&K – Marlton, NJ Accreditation: NVLAP Asbestos Bulk Accredited Laboratory # 200844-0

PLM Laboratory Analysis Result

BUILDING

SAMPLE # ROOF AREA SAMPLE DESCRIPTION LABORATORY RESULTS

1A 1 1 Roof core (3 layers) No Asbestos Detected

1A 2 1 Flashing (3 layers) No Asbestos Detected

1A 3 1 Vapor barrier No Asbestos Detected

1A 4 2 Roof core (3 layers) No Asbestos Detected

1A 5 2 Flashing No Asbestos Detected

1A 6 2 Vapor barrier No Asbestos Detected

1A 7 4 Roof core (2 layers) No Asbestos Detected

1A 8 4 Vapor barrier No Asbestos Detected

1A 9 6 Roof core (3 layers) No Asbestos Detected

1A 10 6 Vapor barrier (2 layers) No Asbestos Detected

1A 11 6 Flashing (2 layers) 4% Chrysotile Asbestos

30 12 7 Roof core (5 layers) No Asbestos Detected

30 13 7 Vapor barrier (2 layers) No Asbestos Detected

30 14 7 Flashing (2 layers) 5% Chrysotile Asbestos

21 15 9 Vapor barrier No Asbestos Detected

15 16 10 Roof core (3 layers) No Asbestos Detected

15 17 10 Vapor barrier No Asbestos Detected

15 18 10 Flashing on roof vent No Asbestos Detected

15 19 10 Flashing on side of roof No Asbestos Detected

11A 20 8 Flashing No Asbestos Detected

11A 21 8 Roof core No Asbestos Detected

11A 22 8 Vapor barrier (2 layers) No Asbestos Detected

11A 23 8 Flashing No Asbestos Detected

11A 24 8 Roof core (2 layers) No Asbestos Detected

11A 25 8 Vapor barrier No Asbestos Detected

1A 26 5 Vapor barrier (2 layers) No Asbestos Detected

• Asbestos containing materials are defined by containing greater than 1% asbestos.

ASBESTOS LABORATORY REPORTS

EMLAB/P&K

Approved by:

Approved Signatory Balu Krishnan

Report for:

Mr. Brett Brumbaugh, REPA Castle Hill Associates PO Box 283 Waterville, OH 43566

Regarding: Project: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

EML ID: 2143472

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 04-23-2019 and 04-24-2019

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 2143472, Page 1 of 9EMLab P&K, LLC

EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Total Samples Submitted: 26 Total Samples Analyzed: 26

Total Samples with Layer Asbestos Content > 1%: 2

Location: 1, Roof 1 - Bldg. 1A Lab ID-Version‡: 10163675-1

Sample Layers Asbestos Content Black Roofing Felt ND

Black Roofing Tar and Felt ND Black Roofing Shingle with White Pebbles ND

Composite Non-Asbestos Content: 20% Cellulose 15% Glass Fibers

Sample Composite Homogeneity: Good

Location: 2, Roof 1 - Bldg. 1A Lab ID-Version‡: 10163676-1

Sample Layers Asbestos Content Black Roofing Felt ND

Black Roofing Tar and Felt ND Black Roofing Shingle with White Pebbles ND

Composite Non-Asbestos Content: 20% Cellulose 15% Glass Fibers

Sample Composite Homogeneity: Good

Location: 3, Roof 1 - Bldg. 1A Lab ID-Version‡: 10163677-1

Sample Layers Asbestos Content Black Tar ND Composite Non-Asbestos Content: 3% Cellulose

2% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 2 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Location: 4, Roof 2 - Bldg. 1A Lab ID-Version‡: 10163678-1

Sample Layers Asbestos Content Brown Fibrous Material ND

Black Roofing Tar and Felt ND Dark Gray Felt ND

Composite Non-Asbestos Content: 30% Cellulose 15% Glass Fibers 5% Synthetic Fibers

Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 3 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Location: 5, Roof 2 - Bldg. 1A Lab ID-Version‡: 10163679-1

Sample Layers Asbestos Content Black Roofing Shingle with White Pebbles ND

Composite Non-Asbestos Content: 10% Cellulose 3% Glass Fibers

Sample Composite Homogeneity: Good

Location: 6, Roof 2 - Bldg. 1A Lab ID-Version‡: 10163680-1

Sample Layers Asbestos Content Black Roofing Shingle with White Pebbles ND

Composite Non-Asbestos Content: 10% Cellulose 3% Glass Fibers

Sample Composite Homogeneity: Good

Location: 7, Roof 4 - Bldg. 1A Lab ID-Version‡: 10163681-1

Sample Layers Asbestos Content Black Roofing Material ND

Yellow Foam ND Composite Non-Asbestos Content: 20% Cellulose Sample Composite Homogeneity: Good

Location: 8, Roof 4 - Bldg. 1A Lab ID-Version‡: 10163682-1

Sample Layers Asbestos Content Black Roofing Material ND

Yellow Foam ND Composite Non-Asbestos Content: 20% Cellulose Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 4 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Location: 9, Roof 6 - Bldg. 30 Lab ID-Version‡: 10163683-1

Sample Layers Asbestos Content Black Roofing Tar and Felt ND

Black Roofing Shingle with Paper ND Brown Roofing Felt ND

Composite Non-Asbestos Content: 25% Cellulose 10% Glass Fibers

Sample Composite Homogeneity: Good

Location: 10, Roof 6 - Bldg. 30 Lab ID-Version‡: 10163684-1

Sample Layers Asbestos Content Black Tar ND

Brown Paper ND Composite Non-Asbestos Content: 25% Cellulose

10% Glass Fibers Sample Composite Homogeneity: Good

Location: 11, Roof 6 - Bldg. 30 Lab ID-Version‡: 10163685-1

Sample Layers Asbestos Content Black Roofing Tar and Felt 4% Chrysotile

Black Tar 2% Chrysotile Composite Non-Asbestos Content: 15% Glass Fibers

5% Cellulose Sample Composite Homogeneity: Good

Location: 12, Roof 7 - Bldg. 30 Lab ID-Version‡: 10163686-1

Sample Layers Asbestos Content Black Roofing Material with Brown Paper ND

Black Roofing Tar and Felt ND Dark Gray Foam ND

Beige Roofing Material Wafer ND White Rock ND Composite Non-Asbestos Content: 15% Cellulose

10% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 5 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Location: 13, Roof 7 - Bldg. 30 Lab ID-Version‡: 10163687-1

Sample Layers Asbestos Content Black Roofing Tar ND

Brown Paper ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Location: 14, Roof 7 - Bldg. 30 Lab ID-Version‡: 10163688-1

Sample Layers Asbestos Content Black Roofing Tar and Felt 5% Chrysotile

Black Tar 3% Chrysotile Composite Non-Asbestos Content: 15% Glass Fibers

5% Cellulose Sample Composite Homogeneity: Poor

Location: 15, Roof 9 - Bldg. 21 Lab ID-Version‡: 10163689-1

Sample Layers Asbestos Content Black Roofing Material ND

Composite Non-Asbestos Content: 7% Cellulose Sample Composite Homogeneity: Good

Location: 16, Roof 10 - Bldg. 15 Lab ID-Version‡: 10163690-1

Sample Layers Asbestos Content Black Roofing Shingle with White Pebbles ND

Black Roofing Tar and Felt with Paper ND Yellow Foam ND

Composite Non-Asbestos Content: 20% Cellulose 15% Glass Fibers

Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 6 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Location: 17, Roof 10 - Bldg. 15 Lab ID-Version‡: 10163691-1

Sample Layers Asbestos Content Black Roofing Felt ND

Composite Non-Asbestos Content: 10% Glass Fibers 3% Cellulose

Sample Composite Homogeneity: Good

Location: 18, Roof 10 - Bldg. 15 Lab ID-Version‡: 10163692-1

Sample Layers Asbestos Content Black Roofing Tar ND

Sample Composite Homogeneity: Good

Location: 19, Roof 10 - Bldg. 15 Lab ID-Version‡: 10163693-1

Sample Layers Asbestos Content Black Roofing Shingle with White Pebbles ND

Composite Non-Asbestos Content: 25% Synthetic Fibers Sample Composite Homogeneity: Good

Location: 20, Roof 8 - Bldg. 11A Lab ID-Version‡: 10163694-1

Sample Layers Asbestos Content Black Roofing Material ND

Composite Non-Asbestos Content: 3% Cellulose Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 7 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Location: 21, Roof 8 - Bldg. 11A Lab ID-Version‡: 10163695-1

Sample Layers Asbestos Content Black Roofing Material ND

Composite Non-Asbestos Content: 3% Cellulose Sample Composite Homogeneity: Good

Location: 22, Roof 8 - Bldg. 11A Lab ID-Version‡: 10163696-1

Sample Layers Asbestos Content Black Roofing Tar ND Black Roofing Felt ND

Composite Non-Asbestos Content: 20% Glass Fibers Sample Composite Homogeneity: Good

Location: 23, Roof 8 - Bldg. 11A Lab ID-Version‡: 10163697-1

Sample Layers Asbestos Content Black Roofing Tar ND

Sample Composite Homogeneity: Good

Location: 24, Roof 8 - Bldg. 11A Lab ID-Version‡: 10163698-1

Sample Layers Asbestos Content Black Roofing Tar ND Black Roofing Felt ND

Composite Non-Asbestos Content: 20% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 8 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: Castle Hill Associates C/O: Mr. Brett Brumbaugh, REPA Re: Jesse Brown VAMC - Chicago, IL; Replace Multiple Roofs - 537-15-128

Date of Sampling: 04-14-2019 Date of Receipt: 04-19-2019 Date of Report: 04-24-2019

ASBESTOS PLM REPORT

Location: 25, Roof 8 - Bldg. 11A Lab ID-Version‡: 10163699-1

Sample Layers Asbestos Content Black Roofing Tar ND

Composite Non-Asbestos Content: 3% Cellulose Sample Composite Homogeneity: Good

Location: 26, Roof 5 - Bldg. 1A Lab ID-Version‡: 10163700-1

Sample Layers Asbestos Content Gray Paper ND Yellow Felt ND Composite Non-Asbestos Content: 65% Cellulose Sample Composite Homogeneity: Good

EMLab ID: 2143472, Page 9 of 9EMLab P&K, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is