About this file

36C25218B0106 00005 CS101.pdf

View the file

Other files

File Type Posted
36C25218B0106-00005007.pdf PDF
36C25218B0106-00005001.pdf PDF
36C25218B0106-00005009.pdf PDF
36C25218B0106-00005002.pdf PDF
36C25218B0106-00005005.pdf PDF
36C25218B0106-00005006.pdf PDF
36C25218B0106-00005008.pdf PDF
36C25218B0106-00005000.docx DOCX document
36C25218B0106-00005004.pdf PDF
36C25218B0106-00004000.docx DOCX document
36C25218B0106-00003000.docx DOCX document
36C25218B0106-00002000.docx DOCX document
36C25218B0106-00001001.pdf PDF
36C25218B0106-00001000.docx DOCX document
36C25218B0106-00001002.pdf PDF
36C25218B0106-005.pdf PDF
36C25218B0106-002.pdf PDF
36C25218B0106-004.pdf PDF
36C25218B0106-003.pdf PDF
36C25218B0106-006.pdf PDF
36C25218B0106-001.docx DOCX document
36C25218B0106-000.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

GUIDON DESIGN INC.

905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204

317.800.6388 | WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

Consultant:

NON-SPRINKLERED

BLDG 112RING & DuCHATEAU LLP

17400 W. CAPITOL DRIVE

BROOKFIELD, WI 53045

(414) 778-1700

REPAIR CAMPUS STEAM TUNNEL

AND STRUCTURAL SUPPORTS

MILWAUKEE VAMC

695-17-119

JIM BEIER, COR, VAMC

Revisions: Date: 01 SEPTEMBER 2017

100% BID SET

KC HF

0 4020

N

CS101

SITE PLAN

1/29/2018

ACCOMPANYING AMENDMENT 36C25218B0106 00005

AutoCAD SHX Text

TRANSFORMERS

AutoCAD SHX Text

CONC WALL

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

SPRINKLER CONTROL BOX

AutoCAD SHX Text

FOUND IRON ROD

AutoCAD SHX Text

PER PLAN

AutoCAD SHX Text

PER PLAN

AutoCAD SHX Text

PER PLAN

AutoCAD SHX Text

PER PLAN

AutoCAD SHX Text

UNIDENTIFIED UNDERGROUND PIPE (PER PLAN)

AutoCAD SHX Text

PIPE CROSSING IN UNDERGROUND STEAM TUNNEL

AutoCAD SHX Text

CONTRACTOR TO PROTECT EXISTING UTILITIES (TYP)

AutoCAD SHX Text

AutoCAD SHX Text

LUKE J LEISING 43897-6 INDIANAPOLIS, IN

AutoCAD SHX Text

SITE PLAN KEYNOTES

AutoCAD SHX Text

1. ASPHALT PAVEMENT ASPHALT PAVEMENT 2. CONCRETE CURB AND GUTTER CONCRETE CURB AND GUTTER 3. CONCRETE SIDEWALK CONCRETE SIDEWALK 4. REPLACE TREE PER SCHEDULE BELOW REPLACE TREE PER SCHEDULE BELOW 5. EXCAVATION LIMITS EXCAVATION LIMITS 6. ADA RAMP WITH TRUNCATED DOMES, SEE DETAIL SHEET CS501 ADA RAMP WITH TRUNCATED DOMES, SEE DETAIL SHEET CS501 7. PROVIDE TWO MECHANICAL DUCT PLUGS FOR EXISTING 4-INCH BURIED PROVIDE TWO MECHANICAL DUCT PLUGS FOR EXISTING 4-INCH BURIED CONDUITS IN AN EXISTING MANHOLE. ONE CONDUIT IS EMPTY AND WILL REQUIRE A SOLID MECHANICAL PLUG. THE CONDUIT HAS FOUR EXISTING COMMUNICATIONS CABLES WHICH WILL NEED TO BE INCORPORATED INTO THE DESIGN OF THE SECOND MECHANICAL PLUG WHEN ORDERING BOTH PRODUCTS. INCLUDE LABOR, MATERIAL, AND EQUIPMENT COST IN THE BID TO PHYSICALLY SURVEY THE MANHOLE CONTAINING THESE TWO CONDUITS, WHICH IS REQUIRED TO OBTAIN EXACT OUTSIDE DIAMETER OF EACH CABLE AND THE EXACT INSIDE DIAMETER OF THE CONDUITS. PROVIDE SUBMITTAL FOR SELECTED PRODUCT IN ACCORDANCE WITH 01 33 23 SHOP DRAWINGS. TREE REPLACEMENT SCHEDULE

VHAMIWAvenaP Line

VHAMIWAvenaP Line

VHAMIWAvenaP Line

VHAMIWAvenaP Line

VHAMIWAvenaP Typewritten Text

VHAMIWAvenaP Text Box Ammendment 5