About this file

This federal contract opportunity is for Project #541-18-101: Upgrade Fire Alarm System at the Louis Stokes Veterans Affairs Medical Center in Cleveland, Ohio. The multi-phase project will upgrade the existing fire alarm system to address deficiencies and meet all NFPA codes and current guidelines. Phase 1 involves installing a new campus fiber loop and NotifierA head end units, which will be fully tested prior to Phase 2. Phase 2 includes tracing and rewiring existing field devices as needed, reprogramming devices to report to the correct control panel, and ensuring each smoke compartment/zone has its own NotifierA control panel with all associated devices contained within. The project magnitude is between $2,000,000 and $5,000,000 and shall be completed within 425 calendar days of receiving the Notice to Proceed. Interested parties must register at beta.sam.gov by the bid opening date to receive solicitation documents and amendments posted on or around November 24, 2020. Questions may be emailed to the contracting officer by the specified deadline.

View the file

Other files

File Type Posted
36C25020B0065 0010.docx DOCX document
WD Cuyahoga 07.30.2021.pdf PDF
280500 - COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY. - Revised 7-26 -2021.pdf PDF
36C25020B0065 0009.docx DOCX document
36C25020B0065 0008.docx DOCX document
36C25020B0065 0007.docx DOCX document
541-18-101 - Upgrade Fire Alarm - Bid Documents Drawings_Part7.pdf PDF
541-18-101 - Upgrade Fire Alarm - Bid Documents Drawings_Part6.pdf PDF
36C25020B0065 0006.docx DOCX document
36C25020B0065 0005.docx DOCX document
541-18-101 - Upgrade Fire Alarm - Bid Documents Drawings_Part5.pdf PDF
36C25020B0065 0004.docx DOCX document
541-18-101 - Upgrade Fire Alarm - Bid Documents Drawings_Part3.pdf PDF
36C25020B0065 0003.docx DOCX document
36C25020B0065 0002.docx DOCX document
541-18-101 - Upgrade Fire Alarm - Bid Documents Drawings_Part2.pdf PDF
541-18-101 - Upgrade Fire Alarm - Bid Documents Drawings_Part1 (1).pdf PDF
36C25020B0065 0001.docx DOCX document
541-18-101 - Upgrade Fire Alarm - Bid Documents Specifications 02.pdf PDF
36C25020B0065_1.docx DOCX document
CUY WD 04.30.2021.pdf PDF
VAMC Health Requirements 05.26.2021.pdf PDF
Notifier JA Complete REDACTED.pdf PDF
VHA Directive 1192.01, Seasonal Influenza Prevention Program for VHA Health Care Personnel.pdf PDF
Corwin Russwin JA Complete REDACTED.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TS

WF

P

TS

WF

P

RS

RS

P P

CM

P

TS

WF

P

WF

TS

TS

WF

P

P

P

DN

DN

UP

█N3 L2 M41

█N3 L2 M39█N3 L2 M40

█N3 L3 M66

█N3 L3 M67

█N3 L3 M68

Toilet/ Shower-1 3B134A-1

Toilet/ Shower-1 3B132A-1

Private-1 3B132-1

Private Isolation-1 3B134-1

Quiet Room-1 3B136-1

Stair 24-1 3F-S4-1

Mechanical Room-1 K302-1

Stair 21-1 3F-S3-1

Mechanical Room-1 K304-1

█N3 L2 D33█N3 L2 D34

CONDUIT STUB

FROM BELOW

CONDUIT STUB

FROM BELOW

Z5

Y5

W5

L2L1

Y2W2U2S2P2

H1 B1

H2

H

H4

H5

H6

H7

H8

H9

H10

H11

G1

G2

G3

G4

G5

G7

F1

F2

F3

F4

F5

F7

C1

C2

C3

A2

G8 F8

G9 F9 E9

G10 F10 E10

G11 F11 E11

XN

XN

█N3 L3 M53█N3 L3 M54█N3 L3 M78█N3 L3 M76

█N3 L3 M52

█N3 L3 D17

█N3 L3 D50

█N3 L3 M51█N3 L3 M50

█N3 L3 M60

NO RESP

█N3 L3 D52

█N3 L3 D51

█N3 L3 D54

█N3 L3 M71

On-Call Toilet/Shower 2D129C

On-Call Toilet/Shower

2D129D

On-Call Room

2E344E

On-Call Room 2E344F

On-Call Lounge

2E344

Elec. Closet

2E347

Pharmacy Office

2E348

Toilet/ Shower 2E336A

Conference/ Classroom 2E345

Office 2E342

Doctor's Conference 2E343

Private

2E336

Toilet/ Shower

2E339A

Private

2E339

Stair #2

2E341 Storage/ Equipment

2E346

Corridor 2E300D

Corridor

2E300E

EMS Closet

K221

On-Call Room

2E344A

On-Call Room 2E344B

Corridor

2E400B

Stair

2E480A

Research Laboratory K219

Office K220A

Office K219A

Research Laboratory K220

Comm.

K223

Elect.

K222

Corridor K221

Mech

K224

Stair 1 K225

Corridor

K200A

Office

K218A

Corridor K200B

Research Cancer K217

Office

K217A

Office

K215A

Research Optometry

K215

Research Surgery K216

Research Laboratory K218

Service Elevator Lobby

K200

Tissue Culture K202

Storage

K216A

Comp.

K201A

Endo Laboratory

K201

Research Vascular

K203

Office K205B

Office K203A

Cooler

K204

Research Laboratory K205

Endo Laboratory

K206

Motion Studies Lab

K205A

Storage K205C

Office K207A

Derm Laboratory

K207

Derm Laboratory

K210

Cancer Research K212

Corridor K200D

Temp Control

K208

Office K206A

Office K211A

Derm Laboratory

K211

Women

K214Men

K213

Stair 2 K212A

FAZE

NEW

CONDUIT STUB

FROM BELOW

CONDUIT STUB

UP TO PENTHOUSE

Z5 Z6

Y5 Y6

W5 W6

V6

Q6

N6

R5R2R1

P2P1 P5

L2L1 L6L5

L2 1 L2 5

Y2W2U2S2P2

1C

3B 4B 5B 6B 7 B

3D 4D 5D 6D 7D

H1 B1

H2

H3

H4

H5

H6

H7

H8

H9

H10

H11

G1

G2

G3

G4

G5

G7

F1

F2

F3

F4

F5

F7

C1

C2

C3

A2

E5

G8 F8 E8

G9 F9 E9

G10 F10 E10

G11 F11 E11

NEW

NEW

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

S

59459

M.P. LONG

R

ES

O F

I R

GE

NOI

S

P

E

N E

DERT

L EA

E I N

G

R

TS

TEA HF OO

IO

CONSULTANTS: ARCHITECT:

Drawing Title Project NumberProject Title

Building Number

Approved: Location

LOUIS STOKES MEDICAL CENTER 10701 EAST BLVD.

Office of

Facilities

Management

FULLY SPRINKLERED

Date

05/14/21

Checked Drawn

Drawing Number

Dwg. of DateRevisions:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

D

C

B

A

E

F

D

C

B

A

E

F

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

VA FORM 08-6231, OCT 1978

DOCUMENT SET MUST BE PRINTED IN COLOR

BID DOCUMENTS SUBMISSION 05/14/21 17069

NODE 4.1 - RESEARCH WING

SECOND AND THIRD FLOOR -

ADDRESSABLE

541-18-101UPGRADE FIRE ALARM

MPL CPC

FA-A-4.1b

8' 16' 32' 64'

1/16" = 1' 0"

THIRD FLOOR FIRE ALARM PLAN - ADDRESSABLE - NODE 4.1 1

8' 16' 32' 64'

1/16" = 1' 0"

SECOND FLOOR FIRE ALARM PLAN - ADDRESSABLE - NODE 4.1 2

NOT TO SCALE

NODE 4.1 - THIRD FLOOR

FIRE ALARM KEY PLAN

NOT TO SCALE

NODE 4.1 - SECOND FLOOR

FIRE ALARM KEY PLAN

FIRE ALARM ADDRESSABLE DEVICE SCHEDULE - RESEARCH WING - SECOND - NODE 4.1

DEVICE TYPE EXISTING FA ADDRESS NEW NODE/LOOP FUNCTION

Smoke Detector N3 L3 D17 N4.1 L3

Smoke Detector N3 L3 D50 N4.1 L3

Smoke Detector N3 L3 D51 N4.1 L3

Smoke Detector N3 L3 D52 N4.1 L3

Smoke Detector N3 L3 D54 N4.1 L3

Water Flow Switch N3 L3 M50 N4.1 L3

Tamper Switch N3 L3 M51 N4.1 L3

Pull Station N3 L3 M52 N4.1 L3

Water Flow Switch N3 L3 M53 N4.1 L3

Tamper Switch N3 L3 M54 N4.1 L3

Pull Station N3 L3 M60 N4.1 L3

Pull Station N3 L3 M71 N4.1 L3

Water Flow Switch N3 L3 M76 N4.1 L3

Tamper Switch N3 L3 M78 N4.1 L3

Control Module NO RESP N4.1 L3 NOT RESPONDING

FIRE ALARM ADDRESSABLE DEVICE SCHEDULE - RESEARCH WING - THIRD FLOOR - NODE 4.1

DEVICE TYPE EXISTING FA ADDRESS NEW NODE/LOOP FUNCTION

Duct Detector N3 L2 D33 N4.1 L3 HOT DECK DETECTOR

Duct Detector N3 L2 D34 N4.1 L3 COLD DECK DETECTOR

Tamper Switch N3 L2 M39 N4.1 L3

Water Flow Switch N3 L2 M40 N4.1 L3

Pull Station N3 L2 M41 N4.1 L3

Pull Station N3 L3 M66 N4.1 L3

Water Flow Switch N3 L3 M67 N4.1 L3

Tamper Switch N3 L3 M68 N4.1 L3

CODED NOTES

1 PROVIDE NEW FIRE ALARM EQUIPMENT AS INDICATED. REFER TO ENLARGED PLANS ON SUBSEQUENT SHEETS FOR

ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING AND DIGITAL AUDIO FIBER OPTIC CABLE FROM NEW NODE EQUIPMENT TO NEW ZONE EQUIPMENT. CONNECT NEW FIRE ALARM POWER SUPPLY AND DIGITAL AUDIO AMPLIFIER COMPLETE AND

PROVIDE (5) NEW ADDRESSES FOR POWER SUPPLY AND (1) NEW ADDRESS FOR AMPLIFIER.

DISCONNECT SLC LOOP WIRING BETWEEN ZONES AND REMOVE EXISTING CONDUIT AND WIRING. DEVICE SHOWN IS ASSUMED TO BE THE LOCATION OF THE CONNECTION BETWEEN ZONES. FIELD VERIFY CONNECTION LOCATION.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING TO EXISTING ADDRESSABLE FIRE ALARM DEVICE TO MIGRATE EXISTING DEVICES TO NEW LOOP. CONNECT DEVICES COMPLETE AND PROVIDE NEW ADDRESS FOR ALL DEVICES IN THE ZONE

HAVE BEEN MIGRATED TO NEW LOOP.

CONTINUATION OF 3/4"C WITH NEW SLC LOOP WIRING FROM NEW NODE DEVICE IN BASEMENT TO NEW ZONE EQUIPMENT ON SECOND FLOOR VIA APPROXIMATE ROUTE SHOWN. CONNECT COMPLETE AS INDICATED TO NEW ZONE EQUIPMENT.

CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING FROM NEW ZONE EQUIPMENT UP TO PENTHOUSE VIA APPROXIMATE ROUTE SHOWN TO MIGRATE EXISTING DEVICES TO NEW LOOP ON SECOND FLOOR. CONDUIT CONTINUES IN PENTHOUSE ROOM

K302 ON THIS SHEET. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING FROM EXISTING FIRE ALARM ADDRESSABLE DEVICE UP TO PENTHOUSE MECHANICAL ROOM K304 TO MIGRATE EXISTING DEVICES TO NEW LOOP ON SECOND FLOOR. ROUTE SHOWN IS

APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION.

CONTINUATION OF NEW CONDUIT WITH SLC LOOP TO MIGRATE DEVICES IN PENTHOUSE ROOM K304 TO NEW LOOP ON

SECOND FLOOR.

CONTINUATION OF NEW CONDUIT WITH SLC LOOP TO MIGRATE DEVICES IN PENTHOUSE ROOM K302 TO NEW LOOP ON

SECOND FLOOR.

REPLACE EXISTING DUCT DETECTOR WITH NEW. DETECTOR SHALL BE SYSTEM SENSOR MODEL "DNR" WITH NOTIFIER COMPATIBLE REMOVABLE AND ADDRESSABLE SMOKE DETECTION HEADS. PROVIDE NEW NOTIFIER "RTS151KEY" REMOTE TEST KEY SWITCH AND MOUNT AT AN ACCESSIBLE LOCATION. CONNECT COMPLETE TO NEW FIRE ALARM ADDRESSABLE CIRCUIT. PROVIDE NEW NOTIFIER "FRM" RELAY MODULE AND CONNECT COMPLETE TO LOCAL HVAC CONTROL PANEL FOR UNIT SHUTDOWN. COORDINATE REPLACEMENT WITH VA FACILITIES DEPARTMENT. PROVIDE 3/4"C AND WIRING AS

REQUIRED TO CONNECT ALL NEW FIRE ALARM DEVICES COMPLETE.

FIRE ALARM DEVICE SCHEDULE NOTES

FA EXISTING DEVICE ADDRESS AND FUNCTION INFORMATION IS FOR REFERENCE ONLY. INFORMATION IS SOURCED

FROM PREVIOUS FIRE ALARM SYSTEM STUDY PROJECT AS WELL AS PROJECT FIRE ALARM SUBMITTALS AND AS-BUILT DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING EXISTING DEVICE ADDRESS AND

FUNCTION PRIOR TO RE-PROGRAMMING DEVICE TO NEW SYSTEM.

FB NEW NODE/LOOP INDICATES THE DESTINATION NODE AND LOOP TO WHICH THE EXISTING FIRE ALARM DEVICE SHALL BE RE-CONNECTED. PROVIDE NECESSARY FIRE ALARM CONDUIT AND WIRING REQUIRED TO RECONNECT EXISTING DEVICES TO NEW NODE AND LOOP AS INDICATED. CONTRACTOR SHALL DOCUMENT NEW DEVICE

ADDRESS FOR ALL RE-CONNECTED FIRE ALARM DEVICES.

FC CONTRACTOR SHALL PROVIDE ALL NECESSARY PROGRAMMING TO TRANSITION EXISTING DEVICE TO NEW FIRE ALARM BACKBONE SYSTEM. PROGRAMMING INCLUDES BUT IS NOT LIMITED TO DEVICE ADDRESS, UPDATING DEVICE LOCATION, DEVICE FUNCTION, DEVICE TYPE, ETC. CONTRACTOR SHALL BE PERMITTED TO MIGRATE EXISTING DEVICES FROM PREVIOUS DATABASE, IF POSSIBLE, BUT SHALL BE RESPONSIBLE FOR MANUALLY UPDATING THE AFORMENTIONED FIELDS AND MANUALLY PROGRAMMING ALL FIRE ALARM DEVICES WHERE DATA

MIGRATION FAILS.

FD REFER TO FIRE ALARM INPUT/OUTPUT MATRIX FOR DEVICE PROGRAMMING.

FE REFER TO FIRE ALARM SYSTEM SPECIFICATIONS FOR ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

FIRE ALARM GENERAL NOTES

F1 ALL FIRE ALARM SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE FIRE ALARM CONTROL SYSTEM IN

ACCORDANCE WITH ENGINEER APPROVED MANUFACTURER'S SHOP DRAWINGS, WIRING DIAGRAMS, AND DETAILS.

F2 ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE INSTALLED IN 3/4" MINIMUM SIZE CONDUIT SYSTEM.

F3 SMOKE DETECTORS SHALL BE INSTALLED ON CEILINGS WITH SPACING NOT TO EXCEED MANUFACTURER'S

RECOMMENDATION AND IN ACCORDANCE WITH NFPA 72.

F4 SMOKE DETECTORS SHALL BE INSTALLED WITHIN 5'-0" OF CENTERLINE OF SMOKE DOORS ON HOLD-OPEN DEVICES.

DETECTORS SHALL BE INSTALLED ON EACH SIDE OF THE DOOR PER VA FIRE PROTECTION DESIGN MANUAL.

F5 FIRE ALARM SYSTEM SHALL BE SUB-DIVIDED INTO ZONES THAT CORRESPOND TO THE SMOKE COMPARTMENTS AND

SPRINKLER ZONES PER VA FIRE PROTECTION DESIGN MANUALS.

F6 ALL EXISTING FIRE ALARM DEVICES THAT WILL NOT BE REUSED IN THE REMODELED INSTALLATION SHALL BE REMOVED UNLESS OTHERWISE NOTED. THIS DEMOLITION SHALL INCLUDED ALL ITEMS SHOWN ON THIS PLAN THAT ARE DESIGNATED BY "XR" AND ALL OTHER ADDITIONAL ITEMS THAT ARE NOT SHOWN BUT THAT MUST BE REMOVED IN ORDER TO PRODUCE A NEAT, FINISHED, PROPERLY FUNCTIONING ELECTRICAL INSTALLATION. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING REUSED DEVICES - PROVIDE ALL CONDUIT AND WIRING NECESSARY TO ACHIEVE THE SAME. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND THE EXTENT OF ALL DEMOLITION WORK AND SHALL INCLUDE COST FOR THE SAME IN THE BID

SUBMITTAL.

F7 ALL EXISTING REMOVED ELECTRICAL EQUIPMENT, DEVICES, ETC. THAT ARE NOT RETAINED BY THE OWNER SHALL BE

DISPOSED OF BY THE ELECTRICAL CONTRACTOR.

F8 REFER TO THE LEGEND FOR ALL SYMBOL DESIGNATIONS. NOTE SPECIAL ATTENTION TO SELECTED EXISTING DEVICES, WIREWAYS, ETC. MARKED "XB", "XRR", OR "XN" AND REMOVE/BLANK OFF, RELOCATE, OR REPLACE THESE COMPONENTS AS

REQUIRED.

F9 CLOSELY COORDINATE ALL DEMOLITION WORK WITH THE GENERAL CONTRACTOR TO PROVIDE PATCHING AND PAINTING

FOR EXISTING WALLS WHERE DEVICES/PANELS ARE REMOVED.

F10 CONTACT THE ENGINEER IF A QUESTION SHOULD ARISE CONCERING THE STATUS OF ANY OUTLET, DEVICE, FIXTURE, ETC.

RESEARCH WING GENERAL NOTE

A PROJECT IS CURRENTLY IN DESIGN TO RENOVATE THE FIRST, SECOND, AND THIRD FLOOR (PENTHOUSE) OF THE RESEARCH WING. VA PROJECT NUMBER 541-20-104. EQUIPMENT PROVIDED WITHIN THE SCOPE OF THIS PROJECT MAY NOT BE REQUIRED IF THE RESEARCH WING PROJECT OCCURS PRIOR TO FIRE ALARM UPGRADE PROJECT IN THIS AREA. COORDINATE

REQUIREMENTS WITH VA AND ENGINEER PRIOR TO WORK IN RESEARCH WING.

DN

P

P

P

HD

P

WF

WF

P

P

P

P P P

P P P

P

P

WF

TS

MM

HD

RS

CM

CM

CM

P

TS TS TS

CM

CM

CM

WF

MM

CM

WF

TS

P

CM

WF TS

WF TS

P

WF TS

TS

MM

MM

MM

CMCMCMCMCMCM

CMCMCMCMCMCM

CMCMCMCMCMCM

CM

CM

CMCMCMCMCM

CMCMCMCMCM

CM

CM

CMCMCMCMCM

CMCMCMCMCM

J

RS

P

P

RS

CM

P P

P

P

P

J J

DN

DN

DN DN

DN

DNDN

DN

DN

DN

█N15 L1 D85

█N14 L1 M25

█N14 L1 M24

█N3 L6 M51

█N3 L6 M52

█N3 L6 M91

█N3 L6 M92

█N3 L6 M93

█N3 L6 M40█N3 L6 M41

█N3 L6 M68

Switch Gear Room

BE504

EMS Equip Stor

BC598

Bio Med Stor

BC597

EMS Equip Stor

BC599

Office Asst Chief

BC593

Office Chief

BC594

Corridor

BF504

Conf Room

BC591

Lock Smith

D25D Transformer Room

D21

Storage D20A

E.C.

G08A

Corridor

CG01

Storage Room

G09B

Storage Room G09

Mechanical & Electrical Room

G09A

Paint Shop

G08

Mechanical Room D20

Primary Switch Room

BD404

Primary Switch Room

BD403

Supv Office

BC491

Repair Station 1

BC490N

Ref. & Files

BC490O

Repair Station 13

BC490B

Bio Med

BC490

Vestibule

BE502

Electric Vestibule

BE501

Storage

B-C595 Fuel Tank Room

BD501

█N14 L1 D1

█N14 L1 D14

█N14 L1 D13 █N14 L1 D150

█N14 L1 D2

█N14 L1 D11 █N14 L1 D10

█N14 L1 D3 █N14 L1 D4 █N14 L1 D5 █N14 L1 D6

█N14 L1 M30

█N14 L1 M31

█N14 L1 M32

█N14 L1 D7

█N14 L1 D52 █N14 L1 D51█N14 L1 D75

█N14 L1 M75

█N14 L1 D59

█N14 L1 D54 █N14 L1 D53 █N14 L1 D58

█N14 L1 D57█N14 L1 D55█N14 L1 D56 █N14 L1 M76

█N14 L1 D67

█N14 L1 D61

█N14 L1 D62 █N14 L1 D63

█N14 L1 D65

█N14 L1 D68 █N14 L1 M77 █N14 L1 D69

█N14 L1 D66

█N14 L1 D64 █N14 L1 D70

█N14 L1 D71

█N14 L1 D72

█N14 L1 M63

█N14 L1 M64█N14 L1 M62

█N14 L1 M5

█N14 L1 M26█N14 L1 M27

█N14 L1 M28

Electrical Room-2

BE602-2

Electrical Room-2

BE601-2

Chiller/ Pump Room-2

BD604-2

Storage

BD601

Chiller Plant Office

BD605A

Office-2

BE603-2

Storage-2

BE606-2

Office-2

BE605-2

Restroom-2

BE604-2

Electric Equipment Room-2

BE607-2

Chiller/Pump Room-2

BD607-2

Mechanical Shop-2

BD606-2

Chiller/ Pump Room-2

BD605-2

█N14 L1 M60

█N14 L1 M57

█N14 L1 M6 █N14 L1 M1

█N14 L1 M7

█N14 L1 M8

█N14 L1 M2

█N14 L1 M9

FAZE

NEW

FAZE

FANE

NEW

NEW

█N14 L1 M58

Pipe Tunnel

BE503

NEW

N E

W

N E

W

NEW

N E

W

Z8 Z10 Z12 Z114A Z115B Z116B Z117C Z118D

Z19 Z22

AA22AA19A

Y115B Y116B Y117C Y118D

X15B X16B X17C X18D

W115B W116B W117B W118D

Y19 Y22

W22W19W18

Y8 Y10 Y12

W8 W10 W12

Z113

Y113

X13 X14A

W13 W14A

AA22

W22

Z22

Y22

E10 D10 C10 B10 A10

E11 D11 C11 B11 A11

E12 D12 C12 B12 A12

19.2

BB.1

19.2

AA.5

23.1

AA.5

23.1

BB.5

(6)

(6)

(6)

(6)

(6)

(6)

(6)

█N14 L1 M59

ANNUNCIATOR

FAT

C

FAR

A

█N14 L1 M22

█N3 L4 M35

█N3 L4 M34█N3 L4 M43

█N14 L1 M23

Storage-1

BE606-1

Electrical Room-1

BE602-1

Stair 1E501

Generators 1E500

Chiller/ Pump

Room-1

BD604-1

Electrical Room-1

BE601-1

Restroom-1

BE604-1

Chiller/Pump Room-1

BD607-1

Office-1

BE605-1

Mechanical Shop-1

BD606-1

Electric Equipment

Room-1

BE607-1

Office 1E434

Office 1E435

Office 1E437

Office 1E439

Office 1E433 Office

1E432

Office 1E449

Office 1E430

Office G101C

Energy Engineer

Office G101D

Kit.

1E431A

Corridor 1E431

Office 1E448

Office 1E450

Office 1E452

Office 1E454

Endocrine

Rheumatology Fellows 1E458Office

1E456

Employee Restroom

G101B

Employee Lockers G101A

Corridor 1E400C

Office 1E451

Office 1E453

Office 1E455

Office 1E457

Vestibule 1C583

Exit Passage 1C491

Corridor 1C583

Boiler Room G101

Corridor 1C490

Corridor 1E400E

Admin Office 6 1D461

Chiller/ Pump

Room-1

BD605-1

Office-1

BE603-1

█N3 L4 D35

█N14 L1 D73 █N14 L1 M61

Z8 Z10 Z12 Z114A Z115B Z116B Z117C Z118D

Z19

AA19A

Y115B Y116B Y117C Y118D

X15B X16B X17C X18D

W115B W116B W117B W118D

Y19

W19W18

Y8 Y10 Y12

W8 W10 W12

Z113

Y113

X13 X14A

W13 W14A

19.2

BB.1

19.2

AA.5

Stair #6

1DS1

XN

XR XR

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

S

59459

M.P. LONG

R

ES

O F

I R

GE

NOI

S

P

E

N E

DERT

L EA

E I N

G

R

TS

TEA HF OO

IO

CONSULTANTS: ARCHITECT:

Drawing Title Project NumberProject Title

Building Number

Approved: Location

LOUIS STOKES MEDICAL CENTER 10701 EAST BLVD.

Office of

Facilities

Management

FULLY SPRINKLERED

Date

05/14/21

Checked Drawn

Drawing Number

Dwg. of DateRevisions:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

D

C

B

A

E

F

D

C

B

A

E

F

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

VA FORM 08-6231, OCT 1978

DOCUMENT SET MUST BE PRINTED IN COLOR

BID DOCUMENTS SUBMISSION 05/14/21 17069

NODE 5.1 - ENERGY CENTER

BASEMENT AND FIRST FLOOR -

ADDRESSABLE

541-18-101UPGRADE FIRE ALARM

MPL CPC

FA-A-5.1

8' 16' 32' 64'

1/16" = 1' 0"

BASEMENT FIRE ALARM PLAN - ADDRESSABLE - NODE 5.1 2

8' 16' 32' 64'

1/16" = 1' 0"

FIRST FLOOR FIRE ALARM PLAN - ADDRESSABLE - NODE 5.1 1

NOT TO SCALE

NODE 5.1 - BASEMENT

FIRE ALARM KEY PLAN

NOT TO SCALE

NODE 5.1 - FIRST FLOOR

FIRE ALARM KEY PLAN

CODED NOTES

1 PROVIDE NEW FIRE ALARM EQUIPMENT AS INDICATED. REFER TO ENLARGED

PLANS ON SUBSEQUENT SHEETS FOR ADDITIONAL INFORMATION AND WORK

REQUIREMENTS.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING AND DIGITAL AUDIO FIBER OPTIC

CABLE FROM NEW NODE EQUIPMENT TO NEW ZONE EQUIPMENT. CONNECT

NEW FIRE ALARM POWER SUPPLY AND DIGITAL AUDIO AMPLIFIER COMPLETE

AND PROVIDE (5) NEW ADDRESSES FOR POWER SUPPLY AND (1) NEW ADDRESS

FOR AMPLIFIER.

REMOVE EXISTING FIRE ALARM AMPLIFIER(S), EXTENDER EQUIPMENT, AND ALL

ASSOCIATED CONTROL/MONITORING MODULES COMPLETE BACK TO SOURCE

AFTER NEW FIRE ALARM SYSTEM INSTALLED, EXISTING DEVICES ARE

RECONNECTED, AND COMPLETE SYSTEM TESTING HAS BEEN COMPLETED.

PATCH AND PAINT WALL TO MATCH EXISTING.

DISCONNECT SLC LOOP WIRING BETWEEN ZONES AND REMOVE EXISTING

CONDUIT AND WIRING. DEVICE SHOWN IS ASSUMED TO BE THE LOCATION OF

THE CONNECTION BETWEEN ZONES. FIELD VERIFY CONNECTION LOCATION.

PROVIDE 3/4"C WITH NEW SLC LOOP WING TO EXISTING ADDRESSABLE FIRE

ALARM DEVICE TO MIGRATE EXISTING DEVICES TO NEW LOOP. CONNECT

DEVICES COMPLETE AND PROVIDE NEW ADDRESS FOR ALL DEVICES ON

EXISTING LOOP. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL

DEVICES ARE MIGRATED TO NEW LOOP.

PROVIDE NEW NOTIFIER NCA-2 FIRE ALARM SYSTEM REMOTE ANNUNCIATOR

AND RECONNECT COMPLETE.

PROVIDE 3/4"C WITH SECOND SLC LOOP WIRING FROM ZONE 5.1 EQUIPMENT TO

EXISTING DEVICES IN FUEL TANK ROOM TO MIGRATE EXISTING DEVICES TO

NEW LOOP. CONNECT DEVICES COMPLETE AND PROVIDE NEW ADDRESS FOR

ALL DEVICES ON EXISTING LOOP. CONTRACTOR SHALL BE RESPONSIBLE FOR

ENSURING ALL DEVICES ARE MIGRATED TO NEW LOOP.

PROVIDE NEW ONYXWORKS WORKSTATION IN THIS ROOM. COORDINATE

EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. CONNECT COMPLETE

TO NEW HEAD-END SYSTEM VIA NODE EQUIPMENT IN THIS ZONE PER FIRE

ALARM SYSTEM DIAGRAM, DETAILS, AND MANUFACTURER'S WIRING DIAGRAMS.

REMOVE EXISTING ONYXWORKS WORKSTATION COMPLETE DURING

DEMOLITION OF EXISTING BACKBONE.

FIRE ALARM DEVICE SCHEDULE NOTES

FA EXISTING DEVICE ADDRESS AND FUNCTION INFORMATION IS FOR REFERENCE ONLY. INFORMATION IS SOURCED

FROM PREVIOUS FIRE ALARM SYSTEM STUDY PROJECT AS WELL AS PROJECT FIRE ALARM SUBMITTALS AND AS-BUILT DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING EXISTING DEVICE ADDRESS AND

FUNCTION PRIOR TO RE-PROGRAMMING DEVICE TO NEW SYSTEM.

FB NEW NODE/LOOP INDICATES THE DESTINATION NODE AND LOOP TO WHICH THE EXISTING FIRE ALARM DEVICE SHALL BE RE-CONNECTED. PROVIDE NECESSARY FIRE ALARM CONDUIT AND WIRING REQUIRED TO RECONNECT EXISTING DEVICES TO NEW NODE AND LOOP AS INDICATED. CONTRACTOR SHALL DOCUMENT NEW DEVICE

ADDRESS FOR ALL RE-CONNECTED FIRE ALARM DEVICES.

FC CONTRACTOR SHALL PROVIDE ALL NECESSARY PROGRAMMING TO TRANSITION EXISTING DEVICE TO NEW FIRE ALARM BACKBONE SYSTEM. PROGRAMMING INCLUDES BUT IS NOT LIMITED TO DEVICE ADDRESS, UPDATING DEVICE LOCATION, DEVICE FUNCTION, DEVICE TYPE, ETC. CONTRACTOR SHALL BE PERMITTED TO MIGRATE EXISTING DEVICES FROM PREVIOUS DATABASE, IF POSSIBLE, BUT SHALL BE RESPONSIBLE FOR MANUALLY UPDATING THE AFORMENTIONED FIELDS AND MANUALLY PROGRAMMING ALL FIRE ALARM DEVICES WHERE DATA

MIGRATION FAILS.

FD REFER TO FIRE ALARM INPUT/OUTPUT MATRIX FOR DEVICE PROGRAMMING.

FE REFER TO FIRE ALARM SYSTEM SPECIFICATIONS FOR ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

FIRE ALARM ADDRESSABLE DEVICE SCHEDULE - ENERGY CENTER - BASEMENT - NODE 5.1

DEVICE TYPE EXISTING FA ADDRESS NEW NODE/LOOP FUNCTION

Tamper Switch N3 L6 M40 N5.1 L2

Tamper Switch N3 L6 M41 N5.1 L2

Monitor Module N3 L6 M51 N5.1 L2 PRESSURE

Water Flow Switch N3 L6 M52 N5.1 L2 DRAIN FLOW

Tamper Switch N3 L6 M68 N5.1 L2

Control Module N3 L6 M91 N5.1 L2

Control Module N3 L6 M92 N5.1 L2

Control Module N3 L6 M93 N5.1 L2

Smoke Detector N14 L1 D1 N5.1 L1

Smoke Detector N14 L1 D2 N5.1 L1

Smoke Detector N14 L1 D3 N5.1 L1

Smoke Detector N14 L1 D4 N5.1 L1

Smoke Detector N14 L1 D5 N5.1 L1

Smoke Detector N14 L1 D6 N5.1 L1

Smoke Detector N14 L1 D7 N5.1 L1

Heat Detector N14 L1 D10 N5.1 L1

Smoke Detector N14 L1 D11 N5.1 L1

Smoke Detector N14 L1 D13 N5.1 L1

Smoke Detector N14 L1 D14 N5.1 L1

Smoke Detector N14 L1 D51 N5.1 L1

Smoke Detector N14 L1 D52 N5.1 L1

Smoke Detector N14 L1 D53 N5.1 L1

Smoke Detector N14 L1 D54 N5.1 L1

Smoke Detector N14 L1 D55 N5.1 L1

Smoke Detector N14 L1 D56 N5.1 L1

Smoke Detector N14 L1 D57 N5.1 L1

Smoke Detector N14 L1 D58 N5.1 L1

Smoke Detector N14 L1 D59 N5.1 L1

Smoke Detector N14 L1 D61 N5.1 L1

Smoke Detector N14 L1 D62 N5.1 L1

Smoke Detector N14 L1 D63 N5.1 L1

Smoke Detector N14 L1 D64 N5.1 L1

Smoke Detector N14 L1 D65 N5.1 L1

Smoke Detector N14 L1 D66 N5.1 L1

Smoke Detector N14 L1 D67 N5.1 L1

Smoke Detector N14 L1 D68 N5.1 L1

Smoke Detector N14 L1 D69 N5.1 L1

Smoke Detector N14 L1 D70 N5.1 L1

Smoke Detector N14 L1 D71 N5.1 L1

Smoke Detector N14 L1 D72 N5.1 L1 B-E601

Duct Detector N14 L1 D75 N5.1 L1 RETURN DUCT

Smoke Detector N14 L1 D150 N5.1 L1 NO FLASH

Pull Station N14 L1 M1 N5.1 L1

Pull Station N14 L1 M2 N5.1 L1

Control Module N14 L1 M5 N5.1 L1 HVAC 4 SHUTDOWN

Pull Station N14 L1 M6 N5.1 L1

Pull Station N14 L1 M7 N5.1 L1

Pull Station N14 L1 M8 N5.1 L1

Pull Station N14 L1 M9 N5.1 L1

Pull Station N14 L1 M24 N5.1 L3

Pull Station N14 L1 M25 N5.1 L3

Water Flow Switch N14 L1 M26 N5.1 L2

Tamper Switch N14 L1 M27 N5.1 L2

Tamper Switch N14 L1 M28 N5.1 L2

Monitor Module N14 L1 M30 N5.1 L1 LOW AIR

Tamper Switch N14 L1 M31 N5.1 L1

Water Flow Switch N14 L1 M32 N5.1 L1

Pull Station N14 L1 M57 N5.1 L1

Pull Station N14 L1 M58 N5.1 L1

Pull Station N14 L1 M59 N5.1 L1

Pull Station N14 L1 M60 N5.1 L1

Water Flow Switch N14 L1 M62 N5.1 L1

Tamper Switch N14 L1 M63 N5.1 L1

Pull Station N14 L1 M64 N5.1 L1

Control Module N14 L1 M75 N5.1 L1 HVAC 2 SHUTDOWN

Control Module N14 L1 M76 N5.1 L1 HVAC 3 SHUTDOWN

Control Module N14 L1 M77 N5.1 L1

Smoke Detector NEW DEVICE N5.1 L2

FIRE ALARM ADDRESSABLE DEVICE SCHEDULE - ENERGY CENTER - FIRST FLOOR - NODE 5.1

DEVICE TYPE EXISTING FA ADDRESS NEW NODE/LOOP FUNCTION

Duct Detector N3 L4 D35 N5.1 L2 MEZZANINE LEVEL

Pull Station N3 L4 M34 N5.1 L2

Control Module N3 L4 M35 N5.1 L2 ASH PIT SUPPLY AIR SHUTDOWN

Pull Station N3 L4 M43 N5.1 L2

Smoke Detector N14 L1 D73 N5.1 L3

Pull Station N14 L1 M22 N5.1 L2 B-E601

Pull Station N14 L1 M23 N5.1 L2 FED FROM B-E601

Pull Station N14 L1 M61 N5.1 L3

FIRE ALARM GENERAL NOTES

F1 ALL FIRE ALARM SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE FIRE

ALARM CONTROL SYSTEM IN ACCORDANCE WITH ENGINEER APPROVED

MANUFACTURER'S SHOP DRAWINGS, WIRING DIAGRAMS, AND DETAILS.

F2 ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE INSTALLED IN 3/4" MINIMUM SIZE

CONDUIT SYSTEM.

F3 SMOKE DETECTORS SHALL BE INSTALLED ON CEILINGS WITH SPACING NOT TO

EXCEED MANUFACTURER'S RECOMMENDATION AND IN ACCORDANCE WITH NFPA 72.

F4 SMOKE DETECTORS SHALL BE INSTALLED WITHIN 5'-0" OF CENTERLINE OF SMOKE

DOORS ON HOLD-OPEN DEVICES. DETECTORS SHALL BE INSTALLED ON EACH SIDE

OF THE DOOR PER VA FIRE PROTECTION DESIGN MANUAL.

F5 FIRE ALARM SYSTEM SHALL BE SUB-DIVIDED INTO ZONES THAT CORRESPOND TO

THE SMOKE COMPARTMENTS AND SPRINKLER ZONES PER VA FIRE PROTECTION

DESIGN MANUALS.

F6 ALL EXISTING FIRE ALARM DEVICES THAT WILL NOT BE REUSED IN THE REMODELED

INSTALLATION SHALL BE REMOVED UNLESS OTHERWISE NOTED. THIS DEMOLITION

SHALL INCLUDED ALL ITEMS SHOWN ON THIS PLAN THAT ARE DESIGNATED BY "XR"

AND ALL OTHER ADDITIONAL ITEMS THAT ARE NOT SHOWN BUT THAT MUST BE

REMOVED IN OREDER TO PRODUCE A NEAT, FINISHED, PROPERLY FUNCTIONING

ELECTRICAL INSTALLATION. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING

REUSED DEVICES - PROVIDE ALL CONDUIT AND WIRING NECESSARY TO ACHIEVE

THE SAME. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND THE EXTENT

OF ALL DEMOLITION WORK AND SHALL INCLUDE COST FOR THE SAME IN THE BID

SUBMITTAL.

F7 ALL EXISTING REMOVED ELECTRICAL EQUIPMENT, DEVICES, ETC. THAT ARE NOT

RETAINED BY THE OWNER SHALL BE DISPOSED OF BY THE ELECTRICAL

CONTRACTOR.

F8 REFER TO THE LEGEND FOR ALL SYMBOL DESIGNATIONS. NOTE SPECIAL ATTENTION

TO SELECTED EXISTING DEVICES, WIREWAYS, ETC. MARKED "XB", "XRR", OR "XN"

AND REMOVE/BLANK OFF, RELOCATE, OR REPLACE THESE COMPONENTS AS

REQUIRED.

F9 CLOSELY COORDINATE ALL DEMOLITION WORK WITH THE GENERAL CONTRACTOR

TO PROVIDE PATCHING AND PAINTING FOR EXISTING WALLS WHERE

DEVICES/PANELS ARE REMOVED.

F10 CONTACT THE ENGINEER IF A QUESTION SHOULD ARISE CONCERING THE STATUS

OF ANY OUTLET, DEVICE, FIXTURE, ETC.

P

P

TS

WF

P

HD

HD

MM

MM

M M

M M

M M

HD

HD

HD HD

P

HD

HD

HD

HD

P

P

MM

MM

MM

MM

MM

TS

TS

WF

WF

TS

MM

MM MM

MMMM

MMMM

MM

MM

MM

MM

MM

MM

TS WFMM

MM

MM

MM

MM

MM

TS

CM

CM

RS

RS

RS

RS

P

R S

R S

P

MM

MM

MM

MM

MM

MM

MM

MM

P

MM MM

MM MM

MM

NODE

PNL

NODE

DVC

█N15 L1 M43

█N15 L1 M39█N15 L1 M40█N15 L1 M41

█N15 L1 M42

█N15 L1 D71

█N15 L1 D72

█N15 L1 M45 █N15 L1 M46█N15 L1 M47█N15 L1 M48 █N15 L1 M44

█N15 L1 M38

█N15 L1 D75

█N15 L1 D84

█N15 L1 D76

█N15 L1 D78

█N15 L1 D79

█N15 L1 D85

█N15 L1 D103

█N15 L1 D104

█N15 L1 D106

█N15 L1 D105

█N15 L1 M63█N15 L1 D34

█N15 L1 D60

█N15 L1 M1

█N15 L1 D55

█N15 L1 D56

█N15 L1 M58█N15 L1 M5█N15 L1 M6

█N15 L1 M17

█N15 L1 M15

█N15 L1 M16

█N15 L1 M34 █N15 L1 M35

█N15 L1 M145

█N15 L1 M146

█N15 L1 D93

█N15 L3 M14█N15 L3 M8█N15 L3 M9█N15 L3 M10

█N15 L3 M12

█N15 L1 M50█N15 L1 M67

█N15 L1 M65

█N15 L1 M66 █N15 L1 M32

█N15 L1 M61

█N15 L3 D94 █N15 L3 D100

█N15 L3 D101

█N15 L3 M6█N15 L3 D97

█N15 L3 M15█N15 L3 M16

█N15 L3 D96█N15 L3 D95

█N15 L1 D70

█N15 L1 D74

█N15 L1 D68

█N15 L1 D69

█N15 L1 D80

█N15 L1 M31

█N15 L1 M30

█N15 L1 D88

█N15 L1 D90

█N15 L1 D92

█N15 L1 D91

█N15 L1 D97 █N15 L1 D98 █N15 L1 D99

█N15 L1 D94

█N15 L1 D77 █N15 L1 D82 █N15 L1 D83

█N15 L1 D95 █N15 L1 D96

█N15 L1 D100 █N15 L1 D101 █N15 L1 D102

█N15 L1 D45█N15 L1 D51█N15 L1 D52█N15 L1 D53█N15 L1 D54

█N15 L1 D1

█N15 L1 D89

█N15 L1 D2 █N15 L1 D57█N15 L1 M69█N15 L1 M68

█N15 L1 D58

█N15 L1 D48

█N15 L1 M59

█N15 L1 D33

█N15 L1 D38

█N15 L1 M62 █N15 L1 D39

█N15 L1 D43

█N15 L1 D41

█N15 L1 D44

█N15 L1 D42

█N15 L1 M105█N15 L1 M106

█N15 L1 D81

█N15 L1 M103█N15 L1 M104

█N15 L1 D87

█N15 L1 D86

█N15 L1 D73

█N15 L1 D46 █N15 L1 D47 █N15 L1 D49

█N15 L1 D50

Storekeeper Office

BF537

Storekeeper Office

BF536

EMS

BF527

Corridor

BF520

TSS Clerks

BF535

Mail Drop

BF509

PALMS Neutralization Tanks

BF505

Elevator Equipment Room

BF503

Corridor

BF502

Stair B

BF580

Warehouse Clerks

BF511

Mail Sorting

BF522

Lounge Lockers

BF530

IRM Telecomm Room

BF515

Engineering Closet

BF516

Electrical Panels

BF521

Corridor

BF504

Elevator Equipment Room

BF541

Male Tlt

BF532

Stair A BF550 Female Tlt

BF531

Corridor

BF526

Storage

BF510B

Medical Gas Storage

BF540

Stair 2

BFS3

Exit Passage

BF501

Entry

BF473

Vestibule

BE502

Warehouse Storage

BF510

Corridor

BF525

Storage Bay 7

BF604

Storage-2

BE606-2

█N15 L1 D40

█N15 L1 M29

█N15 L1 M56

█N15 L1 M55

FAPS

FANE

FAZE

NEW

NEW

FAPS

XR

XR

XR

NEW

XR

Storage Bay 6

BF605

Storage Bay 4

BF606

Storage Bay 4

BF607

Storage Bay 3

BF608

Open

BF608A

Storage Bay 2

BF609

Storage Bay 1

BF610

Elevator Control Room

BF622

Stair

BF621

Vestibule

BF620

Elevator Room

BF623

1 █N15 L1 M151█N15 L1 M153█N15 L1 M152

█N15 L1 M150█N15 L1 M154

CONDUIT STUB

UP TO FIRST FL

N E

W

N E

W

N E

W

Z5 Z6 Z7 Z8

1N

2M

1K

1H

1G

1E

1C

3B 4B 5B 6B 8B7B

3D 4D 5D 6D 8D7D

3F 4F 5F 6F 8B7F

3J 4J 5J 6J 8J7J

3L 4L 5L 6L 8L7L

H1 B1G1 F1 C1

NEW

CONDUIT STUB UP TO

SECOND FLOOR PH

XN

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

S

59459

M.P. LONG

R

ES

O F

I R

GE

NOI

S

P

E

N E

DERT

L EA

E I N

G

R

TS

TEA HF OO

IO

CONSULTANTS: ARCHITECT:

Drawing Title Project NumberProject Title

Building Number

Approved: Location

LOUIS STOKES MEDICAL CENTER 10701 EAST BLVD.

Office of

Facilities

Management

FULLY SPRINKLERED

Date

05/14/21

Checked Drawn

Drawing Number

Dwg. of DateRevisions:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

D

C

B

A

E

F

D

C

B

A

E

F

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

VA FORM 08-6231, OCT 1978

DOCUMENT SET MUST BE PRINTED IN COLOR

BID DOCUMENTS SUBMISSION 05/14/21 17069

NODE 6.1 - LAB WAREHOUSE

BASEMENT - ADDRESSABLE

541-18-101UPGRADE FIRE ALARM

MPL CPC

FA-A-6.1a

8' 16' 32' 64'

1/16" = 1' 0"

BASEMENT FIRE ALARM PLAN - ADDRESSABLE - NODE 6.1 1

NOT TO SCALE

NODE 6.1 - BASEMENT

FIRE ALARM KEY PLAN

CODED NOTES

1 PROVIDE NEW FIRE ALARM EQUIPMENT AS INDICATED. REFER TO ENLARGED PLANS ON SUBSEQUENT SHEETS FOR

ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING AND DIGITAL AUDIO FIBER OPTIC CABLE FROM NEW NODE EQUIPMENT TO NEW ZONE EQUIPMENT. CONNECT NEW FIRE ALARM POWER SUPPLY AND DIGITAL AUDIO AMPLIFIER COMPLETE AND

PROVIDE (5) NEW ADDRESSES FOR POWER SUPPLY AND (1) NEW ADDRESS FOR AMPLIFIER.

MODULES ASSOCIATED WITH EXISTING FIRE ALARM EQUIPMENT ARE LOCATED IN THE SAME ROOM AS THE EQUIPMENT.

MODULES ARE SHOWN OUTSIDE ROOM FOR CLARITY.

REMOVE EXISTING FIRE ALARM AMPLIFIER(S), EXTENDER EQUIPMENT, AND ALL ASSOCIATED CONTROL/MONITORING MODULES COMPLETE BACK TO SOURCE AFTER NEW FIRE ALARM SYSTEM INSTALLED, EXISTING DEVICES ARE

RECONNECTED, AND COMPLETE SYSTEM TESTING HAS BEEN COMPLETED.

DISCONNECT SLC LOOP WIRING BETWEEN ZONES AND REMOVE EXISTING CONDUIT AND WIRING. DEVICE SHOWN IS ASSUMED TO BE THE LOCATION OF THE CONNECTION BETWEEN ZONES. FIELD VERIFY CONNECTION LOCATION.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING TO EXISTING ADDRESSABLE FIRE ALARM DEVICE TO MIGRATE EXISTING DEVICES TO NEW LOOP. CONNECT DEVICES COMPLETE AND PROVIDE NEW ADDRESS FOR ALL DEVICES IN THE ZONE

HAVE BEEN MIGRATED TO NEW LOOP.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING FROM NEW NODE DEVICE TO NEW ZONE EQUIPMENT ON FLOOR ABOVE VIA APPROXIMATE ROUTE SHOWN.CONDUIT CONTINUES IN ROOM 1F516 ON SHEET FA-A-6.1b CONTRACTOR SHALL FIELD

VERIFY EXACT LOCATION.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING FROM NEW NODE DEVICE TO NEW ZONE EQUIPMENT IN PENTHOUSE ON SECOND FLOOR VIA APPROXIMATE ROUTE SHOWN.CONDUIT CONTINUES UP THROUGH ROOM 1F544 ON FIRST FLOOR AND CONTINUES IN PENTHOUSE ON SHEET FA-A-6.1b CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION.

FIRE ALARM ADDRESSABLE DEVICE SCHEDULE - LAB WAREHOUSE - BASEMENT - NODE 6.1

DEVICE TYPE

EXISTING FA

ADDRESS NEW NODE/LOOP FUNCTION

Smoke Detector N15 L1 D1 N6.1 L1

Smoke Detector N15 L1 D2 N6.1 L1

Smoke Detector N15 L1 D33 N6.1 L1

Heat Detector N15 L1 D34 N6.1 L1

Smoke Detector N15 L1 D38 N6.1 L1

Smoke Detector N15 L1 D39 N6.1 L1

Smoke Detector N15 L1 D40 N6.1 L1

Smoke Detector N15 L1 D41 N6.1 L1

Smoke Detector N15 L1 D42 N6.1 L1

Smoke Detector N15 L1 D43 N6.1 L1

Smoke Detector N15 L1 D44 N6.1 L1

Smoke Detector N15 L1 D45 N6.1 L1

Smoke Detector N15 L1 D46 N6.1 L1

Smoke Detector N15 L1 D47 N6.1 L1

Smoke Detector N15 L1 D48 N6.1 L1

Smoke Detector N15 L1 D49 N6.1 L1

Smoke Detector N15 L1 D50 N6.1 L1

Smoke Detector N15 L1 D51 N6.1 L1

Smoke Detector N15 L1 D53 N6.1 L1

Smoke Detector N15 L1 D54 N6.1 L1

Duct Detector N15 L1 D55 N6.1 L1

Duct Detector N15 L1 D56 N6.1 L1

Smoke Detector N15 L1 D57 N6.1 L1

Smoke Detector N15 L1 D58 N6.1 L1

Duct Detector N15 L1 D60 N6.1 L1

Heat Detector N15 L1 D68 N6.1 L1

Heat Detector N15 L1 D69 N6.1 L1

Heat Detector N15 L1 D70 N6.1 L1

Heat Detector N15 L1 D71 N6.1 L1

Heat Detector N15 L1 D72 N6.1 L1

Smoke Detector N15 L1 D73 N6.1 L1

Heat Detector N15 L1 D74 N6.1 L1

Smoke Detector N15 L1 D75 N6.1 L1

Smoke Detector N15 L1 D76 N6.1 L1

Smoke Detector N15 L1 D77 N6.1 L1

Smoke Detector N15 L1 D78 N6.1 L1

Smoke Detector N15 L1 D79 N6.1 L1

Smoke Detector N15 L1 D80 N6.1 L1

Smoke Detector N15 L1 D81 N6.1 L1

Smoke Detector N15 L1 D82 N6.1 L1

Smoke Detector N15 L1 D83 N6.1 L1

Heat Detector N15 L1 D84 N6.1 L1

Smoke Detector N15 L1 D85 N6.1 L1

Smoke Detector N15 L1 D86 N6.1 L1

Smoke Detector N15 L1 D87 N6.1 L1

Smoke Detector N15 L1 D88 N6.1 L1

Smoke Detector N15 L1 D89 N6.1 L1

Smoke Detector N15 L1 D90 N6.1 L1

Smoke Detector N15 L1 D91 N6.1 L1

Smoke Detector N15 L1 D92 N6.1 L1

Smoke Detector N15 L1 D93 N6.1 L1

Smoke Detector N15 L1 D94 N6.1 L1

Smoke Detector N15 L1 D95 N6.1 L1

Smoke Detector N15 L1 D96 N6.1 L1

Smoke Detector N15 L1 D97 N6.1 L1

Smoke Detector N15 L1 D98 N6.1 L1

Smoke Detector N15 L1 D99 N6.1 L1

Smoke Detector N15 L1 D100 N6.1 L1

Smoke Detector N15 L1 D101 N6.1 L1

Smoke Detector N15 L1 D102 N6.1 L1

Duct Detector N15 L1 D103 N6.1 L1

Duct Detector N15 L1 D104 N6.1 L1

Duct Detector N15 L1 D105 N6.1 L1

Duct Detector N15 L1 D106 N6.1 L1

Control Module N15 L1 M1 N6.1 L1 AUTO DOOR DISABLE

Monitor Module N15 L1 M5 N6.1 L1 AC2 SMOKE MONITOR

Monitor Module N15 L1 M6 N6.1 L1 AC1 SMOKE MONITOR

Tamper Switch N15 L1 M15 N6.1 L1

Monitor Module N15 L1 M16 N6.1 L1 LOW PRESSURE DRY SYSTEM

Water Flow Switch N15 L1 M17 N6.1 L1

Pull Station N15 L1 M29 N6.1 L1

Pull Station N15 L1 M30 N6.1 L1

Pull Station N15 L1 M31 N6.1 L1

Tamper Switch N15 L1 M32 N6.1 L1 ELEVATOR ROOM

Tamper Switch N15 L1 M34 N6.1 L1

Water Flow Switch N15 L1 M35 N6.1 L1

Tamper Switch N15 L1 M38 N6.1 L1

Monitor Module N15 L1 M39 N6.1 L1 PRIMARY

Monitor Module N15 L1 M40 N6.1 L1 SECONDARY

Monitor Module N15 L1 M41 N6.1 L1 FIRE HAT

Monitor Module N15 L1 M42 N6.1 L1 SMOKE IN SHAFT

Monitor Module N15 L1 M43 N6.1 L1 ACU5 SMOKE MONITOR

Monitor Module N15 L1 M44 N6.1 L1 ACU9 SMOKE MONITOR

Monitor Module N15 L1 M45 N6.1 L1 PRIMARY

Monitor Module N15 L1 M46 N6.1 L1 SECONDARY

Monitor Module N15 L1 M47 N6.1 L1 FIRE HAT

Monitor Module N15 L1 M48 N6.1 L1 SMOKE IN SHAFT

Monitor Module N15 L1 M50 N6.1 L1 SMOKE IN SHAFT

Monitor Module N15 L1 M55 N6.1 L1 AC SMOKE MONITOR

Monitor Module N15 L1 M56 N6.1 L1 AC SMOKE MONITOR

Control Module N15 L1 M58 N6.1 L1 RELEASE SECURED DOORS

Monitor Module N15 L1 M59 N6.1 L1 SECONDARY

Monitor Module N15 L1 M61 N6.1 L1 ACU6 MONITOR

Monitor Module N15 L1 M62 N6.1 L1 ACU6 MONITOR

Monitor Module N15 L1 M63 N6.1 L1 ACU10 SMOKE MONITOR

Monitor Module N15 L1 M65 N6.1 L1 PRIMARY

Monitor Module N15 L1 M66 N6.1 L1 SECONDARY

Monitor Module N15 L1 M67 N6.1 L1 FIRE HAT

Monitor Module N15 L1 M68 N6.1 L1 AC2 DAMPER

Monitor Module N15 L1 M69 N6.1 L1 AC1 DAMPER

Monitor Module N15 L1 M103 N6.1 L1

Monitor Module N15 L1 M104 N6.1 L1

Monitor Module N15 L1 M105 N6.1 L1

Monitor Module N15 L1 M106 N6.1 L1

Tamper Switch N15 L1 M145 N6.1 L1

Water Flow Switch N15 L1 M146 N6.1 L1

Monitor Module N15 L1 M150 DEMOLISH - DO NOT RECONNECT FACP POWER SUPPLY MONITOR

Monitor Module N15 L1 M151 DEMOLISH - DO NOT RECONNECT FACP AC FAIL MONITOR

Monitor Module N15 L1 M152 DEMOLISH - DO NOT RECONNECT FACP BATTERY TROUBLE MONITOR

Monitor Module N15 L1 M153 DEMOLISH - DO NOT RECONNECT FACP GROUND FAULT MONITOR

Monitor Module N15 L1 M154 DEMOLISH - DO NOT RECONNECT FACP POWER SUPPLY MONITOR

Smoke Detector N15 L3 D8 N6.1 L1

Smoke Detector N15 L3 D17 N6.1 L1

Smoke Detector N15 L3 D94 N6.1 L1

Smoke Detector N15 L3 D95 N6.1 L1

Heat Detector N15 L3 D96 N6.1 L1

Smoke Detector N15 L3 D97 N6.1 L1

Heat Detector N15 L3 D100 N6.1 L1

Smoke Detector N15 L3 D101 N6.1 L1

Pull Station N15 L3 M6 N6.1 L1

Monitor Module N15 L3 M8 N6.1 L1 PRIMARY RECALL

Monitor Module N15 L3 M9 N6.1 L1 SECONDARY RECALL

Monitor Module N15 L3 M10 N6.1 L1 FLASHING HAT

Monitor Module N15 L3 M12 N6.1 L1 SHUNT TRIP

Monitor Module N15 L3 M14 N6.1 L1 SHUNT POWER AVAILABLE

Water Flow Switch N15 L3 M15 N6.1 L1

Tamper Switch N15 L3 M16 N6.1 L1

FIRE ALARM DEVICE SCHEDULE NOTES

FA EXISTING DEVICE ADDRESS AND FUNCTION INFORMATION IS FOR REFERENCE ONLY. INFORMATION IS SOURCED

FROM PREVIOUS FIRE ALARM SYSTEM STUDY PROJECT AS WELL AS PROJECT FIRE ALARM SUBMITTALS AND AS-BUILT DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING EXISTING DEVICE ADDRESS AND

FUNCTION PRIOR TO RE-PROGRAMMING DEVICE TO NEW SYSTEM.

FB NEW NODE/LOOP INDICATES THE DESTINATION NODE AND LOOP TO WHICH THE EXISTING FIRE ALARM DEVICE SHALL BE RE-CONNECTED. PROVIDE NECESSARY FIRE ALARM CONDUIT AND WIRING REQUIRED TO RECONNECT EXISTING DEVICES TO NEW NODE AND LOOP AS INDICATED. CONTRACTOR SHALL DOCUMENT NEW DEVICE

ADDRESS FOR ALL RE-CONNECTED FIRE ALARM DEVICES.

FC CONTRACTOR SHALL PROVIDE ALL NECESSARY PROGRAMMING TO TRANSITION EXISTING DEVICE TO NEW FIRE ALARM BACKBONE SYSTEM. PROGRAMMING INCLUDES BUT IS NOT LIMITED TO DEVICE ADDRESS, UPDATING DEVICE LOCATION, DEVICE FUNCTION, DEVICE TYPE, ETC. CONTRACTOR SHALL BE PERMITTED TO MIGRATE EXISTING DEVICES FROM PREVIOUS DATABASE, IF POSSIBLE, BUT SHALL BE RESPONSIBLE FOR MANUALLY UPDATING THE AFORMENTIONED FIELDS AND MANUALLY PROGRAMMING ALL FIRE ALARM DEVICES WHERE DATA

MIGRATION FAILS.

FD REFER TO FIRE ALARM INPUT/OUTPUT MATRIX FOR DEVICE PROGRAMMING.

FE REFER TO FIRE ALARM SYSTEM SPECIFICATIONS FOR ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

FIRE ALARM GENERAL NOTES

F1 ALL FIRE ALARM SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE FIRE ALARM CONTROL SYSTEM IN

ACCORDANCE WITH ENGINEER APPROVED MANUFACTURER'S SHOP DRAWINGS, WIRING DIAGRAMS, AND DETAILS.

F2 ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE INSTALLED IN 3/4" MINIMUM SIZE CONDUIT SYSTEM.

F3 SMOKE DETECTORS SHALL BE INSTALLED ON CEILINGS WITH SPACING NOT TO EXCEED MANUFACTURER'S

RECOMMENDATION AND IN ACCORDANCE WITH NFPA 72.

F4 SMOKE DETECTORS SHALL BE INSTALLED WITHIN 5'-0" OF CENTERLINE OF SMOKE DOORS ON HOLD-OPEN DEVICES.

DETECTORS SHALL BE INSTALLED ON EACH SIDE OF THE DOOR PER VA FIRE PROTECTION DESIGN MANUAL.

F5 FIRE ALARM SYSTEM SHALL BE SUB-DIVIDED INTO ZONES THAT CORRESPOND TO THE SMOKE COMPARTMENTS AND

SPRINKLER ZONES PER VA FIRE PROTECTION DESIGN MANUALS.

F6 ALL EXISTING FIRE ALARM DEVICES THAT WILL NOT BE REUSED IN THE REMODELED INSTALLATION SHALL BE REMOVED UNLESS OTHERWISE NOTED. THIS DEMOLITION SHALL INCLUDED ALL ITEMS SHOWN ON THIS PLAN THAT ARE DESIGNATED BY "XR" AND ALL OTHER ADDITIONAL ITEMS THAT ARE NOT SHOWN BUT THAT MUST BE REMOVED IN ORDER TO PRODUCE A NEAT, FINISHED, PROPERLY FUNCTIONING ELECTRICAL INSTALLATION. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING REUSED DEVICES - PROVIDE ALL CONDUIT AND WIRING NECESSARY TO ACHIEVE THE SAME. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND THE EXTENT OF ALL DEMOLITION WORK AND SHALL INCLUDE COST FOR THE SAME IN THE BID

SUBMITTAL.

F7 ALL EXISTING REMOVED ELECTRICAL EQUIPMENT, DEVICES, ETC. THAT ARE NOT RETAINED BY THE OWNER SHALL BE

DISPOSED OF BY THE ELECTRICAL CONTRACTOR.

F8 REFER TO THE LEGEND FOR ALL SYMBOL DESIGNATIONS. NOTE SPECIAL ATTENTION TO SELECTED EXISTING DEVICES, WIREWAYS, ETC. MARKED "XB", "XRR", OR "XN" AND REMOVE/BLANK OFF, RELOCATE, OR REPLACE THESE COMPONENTS AS

REQUIRED.

F9 CLOSELY COORDINATE ALL DEMOLITION WORK WITH THE GENERAL CONTRACTOR TO PROVIDE PATCHING AND PAINTING

FOR EXISTING WALLS WHERE DEVICES/PANELS ARE REMOVED.

F10 CONTACT THE ENGINEER IF A QUESTION SHOULD ARISE CONCERING THE STATUS OF ANY OUTLET, DEVICE, FIXTURE, ETC.

DNDN

DN

DN

P

HD

P

P

P

CM CM CM

C M

TS TS TSWF WF

CM CM

MM MM

CM

P

CM

█N15 L2 M33

█N15 L3 M1

█N15 L1 D134

█N15 L3 M4

█N15 L3 D88

█N15 L3 D86

█N15 L3 D87

█N15 L3 D68

█N15 L3 D85

█N15 L3 D84

█N15 L3 D83

█N15 L3 D82

█N15 L3 D81

█N15 L3 D80

█N15 L3 M13█N15 L2 M32█N15 L2 D105

█N15 L2 D103

█N15 L2 M14█N15 L1 M143

█N15 L1 M144

█N15 L2 M37

█N15 L2 M36

█N15 L3 D9

█N15 L3 D10

█N15 L3 D1 █N15 L3 D2

█N15 L3 D11

█N15 L3 D3

█N15 L3 D12

AFC█N15 L3 D4 █N15 L3 D5

█N15 L3 D13 █N15 L3 D14

█N15 L3 D15

█N15 L3 D7█N15 L2 D109

█N15 L3 D6

█N15 L2 D104

█N15 L3 D16

█N15 L3 D32█N15 L3 D31█N15 L3 D30

█N15 L3 D35

█N15 L3 D29

█N15 L3 D33

█N15 L3 D34

█N15 L3 D28█N15 L3 D27█N15 L3 D26█N15 L3 D25

█N15 L3 D39

█N15 L3 D40 █N15 L3 D41

█N15 L3 D44

█N15 L3 D53

█N15 L3 D45

█N15 L3 D54

█N15 L3 D46

█N15 L3 D63

█N15 L3 D64 █N15 L3 D65

█N15 L3 D47

█N15 L3 D42 █N15 L3 D43

█N15 L3 D48

█N15 L3 D56█N15 L3 D55

█N15 L3 D66

█N15 L3 D67

█N15 L3 D78

█N15 L3 D77

█N15 L3 D76

█N15 L3 D79

█N15 L2 D27

█N15 L2 D28

█N15 L2 D158

█N15 L3 D75

█N15 L3 M3

█N15 L2 D156

█N15 L3 D62

█N15 L3 D74

█N15 L3 D60

█N15 L3 D70

█N15 L3 D51 █N15 L3 D52

█N15 L3 D61

█N15 L3 D72

█N15 L3 D73

█N15 L3 D71

█N15 L2 D149 █N15 L2 D155

█N15 L3 M2

█N15 L3 D59

█N15 L3 D58█N15 L3 D57

█N15 L2 D146█N15 L1 M2

█N15 L2 D147

█N15 L3 D69

█N15 L2 M7

█N15 L2 M8

█N15 L2 M1

█N15 L2 D148

█N15 L2 M15█N15 L2 D145

█N15 L2 D144

█N15 L3 D49 █N15 L3 D50

█N15 L2 M2

█N15 L3 D38

█N15 L3 D24█N15 L3 D23

█N15 L3 D37

█N15 L3 D36

█N15 L3 D22█N15 L3 D21

█N15 L3 D20█N15 L2 D106

█N15 L2 D143

█N15 L3 D19

Conference 1F582

Special Chemistry

1F571

Storage-1

BE606-1

Electrical Room-1

BE602-1

Stair 1E501

Elec Room 1F549

Special Chemestry

1F570

Stair 1F621

Soiled Disposal &

Staging

BF602

Microbiology Office 1F557

Microbiology Office 2 1F556

Bio-Hazard Trash Hold

1F551

Chemesitry Office #4

1F535

Specimen Toilet 1F560

Chief Office 1F523

Assist.

Chief Office 1F524

Clerical 1F526

Fluorescent Microscope

1F530

ANTE

Room 1F531

Mycobacterology

(TB)

Mycology Lab

Biosafety Level 3 1F534

ANTE

Room 1F533

Fluorescent Microscop.

1F579

Chem Office #3

1F577

IT EDU

Office 1F569

IRM

Telecomm

Room 1F515

Blood Bank Office 1F566

Electrical Panel 1F511

ANTE

Room 1F561

Specimen Accessioning

1F564

Phlembotomy Supplies

1F562

Gross & Frozen Section 1F541

Phlembotomy Office 1F563

Pathologist Office 1F548

Toxicology

GM/MASS

SPEC

Testing 1F552

Toxicology

GM/MASS

Spec Extraction

1F553

ICP MASS

SPEC

1F554

Histology Supervisor

Office 1F546

Histology 1F544

Microbiology Specimen

Prep 1F555

Bicrobiology

BSL - 2

Lab 1F558

Ontology 1F543

Chemistry Office #1

1F567

Chemistry Office #2

1F568

Core Lab Automated Chemistry

1F574

Corridor 1F583

Pathologist Office 1F528

Pathologist Office 1F527

Pathologist Office 1F525

Screening Office 1F542

EMS

1F578

Electric Closet 1F516

Microscope & Slide Room 1F545

Corridor 1F547

Supplies 1F575

Immunology 1F576

Lounge 1F581

Molecular Vrology

Lab Biosafety Level 3 1F532

Corridor 1F502

Stair A 1F550

Male Toilets 1F522

Female Toilets 1F520

Corridor-1 1F501-1

Corridor-2 1F501-2

Office 1E482

Conference Room 1E446

Office 1E448

Office 1E450

Work Area 1E484

Investigator K108B

Clean Receiving & Staging

BF601

Elevated Walkway

1F601

Vestibule 1F620

Blood Bank

1F565

Intake 1F540

EMS

1F521

Corridor 1F503

Urinalysis 1F573

Corridor 1F529

Special Chemestry

1F572

█N15 L3 D98

█N15 L3 D99

█N7 L1 D146

FAZE

NEW

NEW

NEW

CONDUIT STUB

FROM BELOW

NEW

NEW

NEW

5NE

W

Z5 Z6 Z7 Z8

1N

2M

1K

1H

1G

1E

1C

3B 4B 5B 6B 8B7 B

3D 4D 5D 6D 8D7D

3F 4F 5F 6F 8B7F

3J 4J 5J 6J 8J7J

3L 4L 5L 6L 8L7L

H1 B1G1 F1 C1

CONDUIT STUB UP

FROM BASEMENT

CONTINUING TO PH

N E

W

N E

W

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

S

59459

M.P. LONG

R

ES

O F

I R

GE

NOI

S

P

E

N E

DERT

L EA

E I N

G

R

TS

TEA HF OO

IO

CONSULTANTS: ARCHITECT:

Drawing Title Project NumberProject Title

Building Number

Approved: Location

LOUIS STOKES MEDICAL CENTER 10701 EAST BLVD.

Office of

Facilities

Management

FULLY SPRINKLERED

Date

05/14/21

Checked Drawn

Drawing Number

Dwg. of DateRevisions:

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

D

C

B

A

E

F

D

C

B

A

E

F

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

VA FORM 08-6231, OCT 1978

DOCUMENT SET MUST BE PRINTED IN COLOR

BID DOCUMENTS SUBMISSION 05/14/21 17069

NODE 6.1 - LAB WAREHOUSE

FIRST FLOOR - ADDRESSABLE

541-18-101UPGRADE FIRE ALARM

MPL CPC

FA-A-6.1b

NOT TO SCALE

NODE 6.1 - FIRST FLOOR

FIRE ALARM KEY PLAN

8' 16' 32' 64'

1/16" = 1' 0"

FIRST FLOOR FIRE ALARM PLAN - ADDRESSABLE - NODE 6.1 2

FIRE ALARM ADDRESSABLE DEVICE SCHEDULE - LAB WAREHOUSE - FIRST FLOOR - NODE 6.1

DEVICE TYPE EXISTING FA ADDRESS NEW NODE/LOOP FUNCTION

Control Module N15 L1 M2 N6.1 L2 DOOR UNLOCK

Tamper Switch N15 L1 M143 N6.1 L2

Water Flow Switch N15 L1 M144 N6.1 L2

Smoke Detector N15 L2 D27 N6.1 L2

Heat Detector N15 L2 D28 N6.1 L2

Smoke Detector N15 L2 D103 N6.1 L2

Smoke Detector N15 L2 D104 N6.1 L2

Smoke Detector N15 L2 D105 N6.1 L2

Smoke Detector N15 L2 D106 N6.1 L2

Smoke Detector N15 L2 D109 N6.1 L2

Smoke Detector N15 L2 D143 N6.1 L2

Smoke Detector N15 L2 D144 N6.1 L2

Smoke Detector N15 L2 D145 N6.1 L2

Smoke Detector N15 L2 D146 N6.1 L2

Smoke Detector N15 L2 D147 N6.1 L2

Smoke Detector N15 L2 D148 N6.1 L2

Smoke Detector N15 L2 D149 N6.1 L2

Smoke Detector N15 L2 D155 N6.1 L2

Smoke Detector N15 L2 D156 N6.1 L2

Smoke Detector N15 L2 D158 N6.1 L2

Monitor Module N15 L2 M1 N6.1 L2 ACU3 MONITOR

Control Module N15 L2 M2 N6.1 L2 ACU3 DAMPER

Monitor Module N15 L2 M7 N6.1 L2 ACU4 MONITOR

Control Module N15 L2 M8 N6.1 L2 ACU4 DAMPER

Tamper Switch N15 L2 M14 N6.1 L2

Pull Station N15 L2 M15 N6.1 L2

Pull Station N15 L2 M32 N6.1 L2

Pull Station N15 L2 M33 N6.1 L2

Water Flow Switch N15 L2 M36 N6.1 L2

Tamper Switch N15 L2 M37 N6.1 L2

Smoke Detector N15 L3 D1 N6.1 L2

Smoke Detector N15 L3 D2 N6.1 L2

Smoke Detector N15 L3 D3 N6.1 L2

Smoke Detector N15 L3 D4 N6.1 L2

Smoke Detector N15 L3 D5 N6.1 L2

Smoke Detector N15 L3 D6 N6.1 L2

Smoke Detector N15 L3 D7 N6.1 L2

Smoke Detector N15 L3 D9 N6.1 L2

Smoke Detector N15 L3 D10 N6.1 L2

Smoke Detector N15 L3 D11 N6.1 L2

Smoke Detector N15 L3 D12 N6.1 L2

Smoke Detector N15 L3 D13 N6.1 L2

Smoke Detector N15 L3 D14 N6.1 L2

Smoke Detector N15 L3 D15 N6.1 L2

Smoke Detector N15 L3 D16 N6.1 L2

Smoke Detector N15 L3 D19 N6.1 L2

Smoke Detector N15 L3 D20 N6.1 L2

Smoke Detector N15 L3 D21 N6.1 L2

Smoke Detector N15 L3 D22 N6.1 L2

Smoke Detector N15 L3 D23 N6.1 L2

Smoke Detector N15 L3 D24 N6.1 L2

Smoke Detector N15 L3 D25 N6.1 L2

Smoke Detector N15 L3 D26 N6.1 L2

Smoke Detector N15 L3 D27 N6.1 L2

Smoke Detector N15 L3 D28 N6.1 L2

Smoke Detector N15 L3 D29 N6.1 L2

Smoke Detector N15 L3 D30 N6.1 L2

Smoke Detector N15 L3 D31 N6.1 L2

Smoke Detector N15 L3 D32 N6.1 L2

Smoke Detector N15 L3 D33 N6.1 L2

Smoke Detector N15 L3 D34 N6.1 L2

Smoke Detector N15 L3 D35 N6.1 L2

Smoke Detector N15 L3 D36 N6.1 L2

Smoke Detector N15 L3 D37 N6.1 L2

Smoke Detector N15 L3 D38 N6.1 L2

Smoke Detector N15 L3 D39 N6.1 L2

Smoke Detector N15 L3 D40 N6.1 L2

Smoke Detector N15 L3 D41 N6.1 L2

Smoke Detector N15 L3 D42 N6.1 L2

Smoke Detector N15 L3 D43 N6.1 L2

Smoke Detector N15 L3 D44 N6.1 L2

Smoke Detector N15 L3 D45 N6.1 L2

Smoke Detector N15 L3 D46 N6.1 L2

Smoke Detector N15 L3 D47 N6.1 L2

Smoke Detector N15 L3 D48 N6.1 L2

Smoke Detector N15 L3 D49 N6.1 L2

Smoke Detector N15 L3 D50 N6.1 L2

Smoke Detector N15 L3 D51 N6.1 L2

Smoke Detector N15 L3 D52 N6.1 L2

Smoke Detector N15 L3 D53 N6.1 L2

Smoke Detector N15 L3 D54 N6.1 L2

Smoke Detector N15 L3 D55 N6.1 L2

Smoke Detector N15 L3 D56 N6.1 L2

Smoke Detector N15 L3 D57 N6.1 L2

Smoke Detector N15 L3 D58 N6.1 L2

Smoke Detector N15 L3 D59 N6.1 L2

Smoke Detector N15 L3 D60 N6.1 L2

Smoke Detector N15 L3 D61 N6.1 L2

Smoke Detector N15 L3 D62 N6.1 L2

Smoke Detector N15 L3 D63 N6.1 L2

Smoke Detector N15 L3 D64 N6.1 L2

Smoke Detector N15 L3 D65 N6.1 L2

Smoke Detector N15 L3 D66 N6.1 L2

Smoke Detector N15 L3 D67 N6.1 L2

Smoke Detector N15 L3 D68 N6.1 L2

Smoke Detector N15 L3 D69 N6.1 L2

Smoke Detector N15 L3 D70 N6.1 L2

Smoke Detector N15 L3 D71 N6.1 L2

Smoke Detector N15 L3 D72 N6.1 L2

Smoke Detector N15 L3 D73 N6.1 L2

Smoke Detector N15 L3 D74 N6.1 L2

Smoke Detector N15 L3 D75 N6.1 L2

Smoke Detector N15 L3 D76 N6.1 L2

Smoke Detector N15 L3 D77 N6.1 L2

Smoke Detector N15 L3 D78 N6.1 L2

Smoke Detector N15 L3 D79 N6.1 L2

Smoke Detector N15 L3 D80 N6.1 L2

Smoke Detector N15 L3 D81 N6.1 L2

Smoke Detector N15 L3 D82 N6.1 L2

Smoke Detector N15 L3 D83 N6.1 L2

Smoke Detector N15 L3 D84 N6.1 L2

Smoke Detector N15 L3 D85 N6.1 L2

Smoke Detector N15 L3 D86 N6.1 L2

Smoke Detector N15 L3 D87 N6.1 L2

Smoke Detector N15 L3 D88 N6.1 L2

Duct Detector N15 L3 D98 N6.1 L2 RTU65 RETURN

Duct Detector N15 L3 D99 N6.1 L2 RTU65 SUPPLY

Control Module N15 L3 M1 N6.1 L2 WINDOW FIRE SHUTTER

Control Module N15 L3 M2 N6.1 L2 WINDOW FIRE SHUTTER

Control Module N15 L3 M3 N6.1 L2 WINDOW FIRE SHUTTER

Pull Station N15 L3 M4 N6.1 L2

Control Module N15 L3 M13 N6.1 L2 RTU65 SHUTDOWN MONITOR

CODED NOTES

1 PROVIDE NEW FIRE ALARM EQUIPMENT AS INDICATED. REFER TO ENLARGED PLANS ON SUBSEQUENT SHEETS FOR

ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING AND DIGITAL AUDIO FIBER OPTIC CABLE FROM NEW NODE EQUIPMENT TO NEW ZONE EQUIPMENT. CONNECT NEW FIRE ALARM POWER SUPPLY AND DIGITAL AUDIO AMPLIFIER COMPLETE AND

PROVIDE (5) NEW ADDRESSES FOR POWER SUPPLY AND (1) NEW ADDRESS FOR AMPLIFIER.

REMOVE EXISTING FIRE ALARM AMPLIFIER(S), EXTENDER EQUIPMENT, AND ALL ASSOCIATED CONTROL/MONITORING MODULES COMPLETE BACK TO SOURCE AFTER NEW FIRE ALARM SYSTEM INSTALLED, EXISTING DEVICES ARE

RECONNECTED, AND COMPLETE SYSTEM TESTING HAS BEEN COMPLETED.

DISCONNECT SLC LOOP WIRING BETWEEN ZONES AND REMOVE EXISTING CONDUIT AND WIRING. DEVICE SHOWN IS ASSUMED TO BE THE LOCATION OF THE CONNECTION BETWEEN ZONES. FIELD VERIFY CONNECTION LOCATION.

PROVIDE 3/4"C WITH NEW SLC LOOP WIRING TO EXISTING ADDRESSABLE FIRE ALARM DEVICE TO MIGRATE EXISTING DEVICES TO NEW LOOP. CONNECT DEVICES COMPLETE AND PROVIDE NEW ADDRESS FOR ALL DEVICES IN THE ZONE

HAVE BEEN MIGRATED TO NEW LOOP.

CONTINUATION OF 3/4"C WITH NEW SLC LOOP WIRING FROM NEW ZONE DEVICE TO NEW ZONE EQUIPMENT VIA

APPROXIMATE ROUTE SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION.

CONTINUATION OF 3/4"C WITH NEW SLC LOOP WIRING FROM NEW ZONE DEVICE BELOW TO NEW ZONE EQUIPMENT IN

PENTHOUSE ABOVE VIA APPROXIMATE ROUTE SHOWN.

CONTINUATION OF 3/4"C WITH NEW SLC LOOP WIRING FROM BELOW TO FEED NEW ZONE EQUIPMENT VIA APPROXIMATE

ROUTE SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION.

FIRE ALARM DEVICE SCHEDULE NOTES

FA EXISTING DEVICE ADDRESS AND FUNCTION INFORMATION IS FOR REFERENCE ONLY. INFORMATION IS SOURCED

FROM PREVIOUS FIRE ALARM SYSTEM STUDY PROJECT AS WELL AS PROJECT FIRE ALARM SUBMITTALS AND AS-BUILT DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING EXISTING DEVICE ADDRESS AND

FUNCTION PRIOR TO RE-PROGRAMMING DEVICE TO NEW SYSTEM.

FB NEW NODE/LOOP INDICATES THE DESTINATION NODE AND LOOP TO WHICH THE EXISTING FIRE ALARM DEVICE SHALL BE RE-CONNECTED. PROVIDE NECESSARY FIRE ALARM CONDUIT AND WIRING REQUIRED TO RECONNECT EXISTING DEVICES TO NEW NODE AND LOOP AS INDICATED. CONTRACTOR SHALL DOCUMENT NEW DEVICE

ADDRESS FOR ALL RE-CONNECTED FIRE ALARM DEVICES.

FC CONTRACTOR SHALL PROVIDE ALL NECESSARY PROGRAMMING TO TRANSITION EXISTING DEVICE TO NEW FIRE ALARM BACKBONE SYSTEM. PROGRAMMING INCLUDES BUT IS NOT LIMITED TO DEVICE ADDRESS, UPDATING DEVICE LOCATION, DEVICE FUNCTION, DEVICE TYPE, ETC. CONTRACTOR SHALL BE PERMITTED TO MIGRATE EXISTING DEVICES FROM PREVIOUS DATABASE, IF POSSIBLE, BUT SHALL BE RESPONSIBLE FOR MANUALLY UPDATING THE AFORMENTIONED FIELDS AND MANUALLY PROGRAMMING ALL FIRE ALARM DEVICES WHERE DATA

MIGRATION FAILS.

FD REFER TO FIRE ALARM INPUT/OUTPUT MATRIX FOR DEVICE PROGRAMMING.

FE REFER TO FIRE ALARM SYSTEM SPECIFICATIONS FOR ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

FIRE ALARM GENERAL NOTES

F1 ALL FIRE ALARM SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE FIRE ALARM CONTROL SYSTEM IN

ACCORDANCE WITH ENGINEER APPROVED MANUFACTURER'S SHOP DRAWINGS, WIRING DIAGRAMS, AND DETAILS.

F2 ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE INSTALLED IN 3/4" MINIMUM SIZE CONDUIT SYSTEM.

F3 SMOKE DETECTORS SHALL BE INSTALLED ON CEILINGS WITH SPACING NOT TO EXCEED MANUFACTURER'S

RECOMMENDATION AND IN ACCORDANCE WITH NFPA 72.

F4 SMOKE DETECTORS SHALL BE INSTALLED WITHIN 5'-0" OF CENTERLINE OF SMOKE DOORS ON HOLD-OPEN DEVICES.

DETECTORS SHALL BE INSTALLED ON EACH SIDE OF THE DOOR PER VA FIRE PROTECTION DESIGN MANUAL.

F5 FIRE ALARM SYSTEM SHALL BE SUB-DIVIDED INTO ZONES THAT CORRESPOND TO THE SMOKE COMPARTMENTS AND

SPRINKLER ZONES PER VA FIRE PROTECTION DESIGN MANUALS.

F6 ALL EXISTING FIRE ALARM DEVICES THAT WILL NOT BE REUSED IN THE REMODELED INSTALLATION SHALL BE REMOVED UNLESS OTHERWISE NOTED. THIS DEMOLITION SHALL INCLUDED ALL ITEMS SHOWN ON THIS PLAN THAT ARE DESIGNATED BY "XR" AND ALL OTHER ADDITIONAL ITEMS THAT ARE NOT SHOWN BUT THAT MUST BE REMOVED IN ORDER TO PRODUCE A NEAT, FINISHED, PROPERLY FUNCTIONING ELECTRICAL INSTALLATION. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING REUSED DEVICES - PROVIDE ALL CONDUIT AND WIRING NECESSARY TO ACHIEVE THE SAME. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND THE EXTENT OF ALL DEMOLITION WORK AND SHALL INCLUDE COST FOR THE SAME IN THE BID

SUBMITTAL.

F7 ALL EXISTING REMOVED ELECTRICAL EQUIPMENT, DEVICES, ETC. THAT ARE NOT RETAINED BY THE OWNER SHALL BE

DISPOSED OF BY THE ELECTRICAL CONTRACTOR.

F8 REFER TO THE LEGEND FOR ALL SYMBOL DESIGNATIONS. NOTE SPECIAL ATTENTION TO SELECTED EXISTING DEVICES, WIREWAYS, ETC.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .