36C25018B0817-011.pdf

PDF 7 MB Posted

Attached to
Expand 8th Floor - Mental Health 506-330
Solicitation number
36C25018B0817
Issued by

About this file

36C25018B0817 S02 - Drawings VOL2-Part 6 - 506-330.pdf

View the file

Other files

File Type Posted
36C25018B0817-0005000.docx DOCX document
36C25018B0817-0005001.pdf PDF
36C25018B0817-0005003.pdf PDF
36C25018B0817-0005002.pdf PDF
36C25018B0817-0004000.docx DOCX document
36C25018B0817-0003001.docx DOCX document
36C25018B0817-0003000.docx DOCX document
36C25018B0817-0002000.docx DOCX document
36C25018B0817-0001000.docx DOCX document
36C25018B0817-005.pdf PDF
36C25018B0817-003.pdf PDF
36C25018B0817-007.pdf PDF
36C25018B0817-008.pdf PDF
36C25018B0817-012.pdf PDF
36C25018B0817-001.docx DOCX document
36C25018B0817-010.pdf PDF
36C25018B0817-013.docx DOCX document
36C25018B0817-016.docx DOCX document
36C25018B0817-009.pdf PDF
36C25018B0817-006.pdf PDF
36C25018B0817-014.pdf PDF
36C25018B0817-015.pdf PDF
36C25018B0817-002.pdf PDF
36C25018B0817-004.pdf PDF
36C25018B0817-000.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CEILING HANGER WIRE

DRYWALL CEILING

CROSS TEE. TYP.

DRYWALL

CEILING CROSS

TEE. TYP.

GYPSUM

BOARD

HANGER WIRE AND MOUNTING CHANNEL

ATTACHED TO STRUCTURE REFER TO

SPECIFICATION SECTION 26 51 00

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

6.35mm (1/4") SCREW

CEILING

MAIN BEAM.

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

(2 m m

(4

2m m

(1")

25mm

(1")

25mm

(1")

25mm

(2")

51mm

(1 1/2") TYP

38mm

(1 m m

(5 /8 m m

6.35mm

(1/4") DIA.

MOUNTING

HOLES TYP. OF

(4)

BASE CLAMP/

BRACKET

9.52mm (3/8")

DIA. HOLE TYP.

OF (6)

9.52mm (3/8") x 16mm (5/8") HEX

HEAD BOLT

9.52mm (3/8") LOCK WASHER

9.52mm (3/8") FLAT WASHER & 9.52mm (3/8") LOCK WASHER

6.35mm

(1/4") THICK

CU BAR

(2'-0") MIN

610mm

6.35mm (1/4")

DIA. HOLE TYP

OF (8)

SECTION

STEEL EXPANSION

ANCHOR

INSULATOR

9.52mm (3/8") FLAT WASHER

GENERAL NOTES

1. ALL HARDWARE SHALL BE STAINLESS STEEL.

2. PROVIDE 1 MOUNTING POINT PER 305mm(12") OF BAR LENGTH.

3. HOLES MAY BE ADDED IF REQUIRED.

(3'-0") MAX

SEISMIC OR EXPANSION

JOINT. FIELD VERIFY

ACTUAL CONDITIONS &

LOCATIONS.FLOOR OR ROOF

STRUCTURE. FIELD VERIFY

ACTUAL CONDITIONS, TYP.

STRUCTURAL MEMBER

(BEAM, JOIST, ETC.), TYP.

JUNCTION BOX,

TYP (SIZE AS REQUIRED)

CONDUIT

TRAPEZE PER

SD260533-03,

TYP.

914mm

BEAM

CLAM,

TYP.

CONDUIT,

TYP.

EXPANSION FITTING

WITH BONDING JUMPER

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

STEEL EXPANSION

ANCHOR

JUNCTION BOX

(SIZE AS REQUIRED)

CONDUIT FITTING

SPRING NUT

HEAD

INSULATING

BUSHING

PROVIDE EXTRA CABLE TO

MAKE COMPLETE LOOP

AROUND BOX PERIMETER

GENERAL NOTES:

1. INSTALLATION IS ACCEPTABLE ALTERNATE TO DETAIL SD260533-01.

2. INSTALLATION IS REQUIRED FOR CONDUIT 76mm (3") AND LARGER.

LENGTH AS REQUIRED

CONDUIT CLAMP.

SIZE AS REQUIRED

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

REFER TO PLANS FOR

QUANTITY & SIZE OF

CONDUITS

LOCKING SQUARE

WASHER & LOCKNUT

9.52mm (3/8") MIN

GALVANIZED THREADED

ROD, TYP.

WASHER &

LOCKNUT

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

GENERAL NOTES:

1. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL

LONGER THAN 915mm (36") SHALL BE INSTALLED WITH A

CENTER SUPPORT ROD.

2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED

METHOD PER SPECIFICATION 26 05 33, RACEWAY AND BOXES

FOR ELECTRICAL SYSTEMS. FIELD VERIFY EXACT

CONDITIONS.

3. FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER TO

SPECIFICATION SECTION 13 05 41, SEISMIC RESTRAINT

REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS.

CONDUIT CLAMP.

SIZE AS REQUIRED

INTEGRAL GALVANIZED

LIPPED STEEL

MOUNTING CHANNEL

REFER TO PLANS

FOR QUANTITY &

SIZE OF CONDUITS

LOCKING

SQUARE WASHER

& LOCKNUT

9.52mm (3/8") MIN

GALVANIZED THREADED

ROD, TYP.

UV-INHIBITED POLYCARBONATE

OR HIGH-DENSITY

POLYPROPYLENE PLASTIC

BLOCK, LENGTH AS REQUIRED

CEILING HANGER WIRE

ARCHITECTURAL

CEILING GRID

ARCHITECTURAL

CEILING GRID

ACOUSTICAL

CEILING TILE

(TYP)

HANGER WIRE AND MOUNTING CHANNEL

ATTACHED TO STRUCTURE REFER TO

SPECIFICATION SECTION 26 51 00

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

6.35mm (1/4") SCREW

ARCHITECTURAL

CEILING GRID

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

PREFABRICATED RUBBER

BOOT CAP WITH GRADUATED

STEPS & WEATHER-PROOF

PRESSURE SEAL TO COLLAR

SEALANT AT PENETRATION

TO MEMBRANE JUNCTURE

BY ROOFING CONTRACTOR

MULTIPLE MEMBRANE STRIPPING

PLIES FEATHERED AT FIELD OF

ROOF BY ROOFING CONTRACTOR.

PRIME FLANGE BEFORE STRIPPING.

PREFABRICATED FORMED 1.52mm (0.06")

THICK ALUMINUM FLASHING

ROUND COLLAR WITH MIN. 76mm (3")

WIDE FLANGE. ATTACH TO ROOF PER

MANUFACTURER'S INSTRUCTIONS

CONDUIT CLAMP. SIZE AS

REQUIRED

BATT INSULATION

ROOF MEMBRANE

WATER CUT-OFF

MASTIC COMPATIBLE

WITH ROOF MEMBRANE

STAINLESS CLAMP, TYP.

9.52mm (3/8") MIN

GALVANIZED

THREADED ROD, TYP.

SEAL-OFF

FITTING,

TYP.

ROOF

STEEL

EXPANSION

ANCHOR

INTEGRAL

GALVANIZED LIPPED

STEEL MOUNTING

CHANNEL

CONDUIT,

TYP.

CONDUIT

CLAMP. SIZE

AS REQUIRED

LOCKING

SQUARE

WASHER &

LOCKNUT

GENERAL NOTES:

1. MAINTAIN A MINIMUM CLEARANCE OF 305mm (12") ON ALL SIDES OF ROOF

PENETRATION FROM CALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE

PROPER FLASHING.

2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.

3. VERIFY ROOF & STRUCTURAL SYSTEM WITH ARCHITECT.

4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO ENSURE

PROPER METHODS & MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.

CEILING HANGER

WIRE, TYP.

RECESSED CAN

LUMINAIRE

REFER TO

SCHEDULE.

CEILING MAIN

BEAM

GYPSUM

BOARD (TYP)

WIRE TIE OR SCREW

BAR HANGER TO

CROSS BEAM TYP.

LUMINAIRE

BAR HANGERS

LUMINAIRE SUSPENSION WIRES

REFER TO SPECIFICATION SECTION 26 51 00

CEILING

CROSS BEAM

RECESSED CAN

LUMINAIRE

CEILING BEAM

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG MAX)

GENERAL NOTES:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

CEILING HANGER

WIRE, TYP.

RECESSED CAN

LUMINAIRE

ARCHITECTURAL

CEILING GRID

WIRE TIE OR SCREW BAR

HANGER TARCHITECTURAL

CEILING GRID TYP.

LUMINAIRE

BAR HANGERS

LUMINAIRE SUSPENSION WIRE

REFER TO SPECIFICATION

SECTION 26 51 00.

ACOUSTICAL

CEILING TILE (TYP)

RECESSED CAN

LUMINAIRE

ARCHITECUTRAL

CEILING GRID

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG MAX)

GENERAL NOTES:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING RECOMMENDED MOUNTING HARDWARE

LUMINAIRE

SUSPENSION WIRES

REFER TO

SPECIFICATION

SECTION 26 51 00

3 TWIST MINIMUM

(TYP)

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG MAX.)

CEILING MAIN BEAM

GYPSUM BOARD (TYP)

LUMINAIRE.

REFER TO

SCHEDULE

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

CEILING CROSS BEAM

GYPSUM BOARD

CEILING CROSS BEAM

LUMINAIRE.

REFER TO

SCHEDULE

DRYWALL BORDER

GENERAL NOTES:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

LUMINAIRE

SUSPENSION WIRES

REFER TO

SPECIFICATION

SECTION 26 51 00

3 TWIST MINIMUM

(TYP)

FIXTURE WHIP

FROM JUNCTION BOX

(1829mm (6') LONG MAX.)

LUMINAIRE.

REFER TO

SCHEDULE

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

ACOUSTICAL CEILING

TILE (TYP)

ARCHITECTURAL

CEILING GRID

LUMINAIRE.

REFER TO

SCHEDULE

GENERAL NOTES:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

(1 2"

M

A X m m

(1 8"

M

A X m m

CAST METAL

"WHILE-IN-USE"

WP COVER(S) &

RECEPTACLE(S).

CAST METAL, 2-GANG,

NEMA 3R JUNCTION BOX

WITH THREADED HUBS.

RIGID STEEL CONDUIT

FOR WIRING

A

A

SECTION "A-A"

ELEVATION

RIGID STEEL CONDUIT

FOR SUPPORT PER

N.E.C. ART. 314

ROOF PENETRATION AND

CONDUIT SUPPORT PER

SD260533-05

(4) CONCRETE BRICKS

51mmx203mmx406mm (2"x8"x16")

CONDUIT(S) WITH BELL ENDS

(TYP). SIZE, QUANTITY AND

WIRING AS INDICATED ON PLANS

CLEAN 19mm (3/4")

CRUSHED ROCK

FINISHED PAVING

V A

R

IE

S (1

2"

PULLBOX (SEE SPECIFICATIONS)

LINE SIDES OF

EXCAVATION

WITH 13.6 KG (30 LBS.)

FELT PAPER

(12")

5m m

305mm

PLASTIC SPACER

INNERDUCT,

SEE NOTE 5

DUCT [SIZE AS

INDICATED ON DWGS.] 6-WAY DUCT LINE 4-WAY DUCT LINE

2-WAY DUCT LINE

TIE WIRE

(3")

(3")

76mm

(3 m m (3 m m

76mm

(3")

76mm

(3 m m

(3 m m

(3 m m

(3")

(3")

76mm

(3")

76mm76mm

(3

(3 m m m m m m

(3

76mm

(3")

76mm (3")

76mm (3")

152mm

(6")(SEE NOTE 4)

(T Y

P

GENERAL NOTES:

1. CONCRETE SHALL BE 2000 P.S.I. @ 28 DAYS, OR AS SPECIFIED.

2. PROVIDE #4 REINFORCING RODS ON TOP AND BOTTOM OF DUCTS

WHEN CROSSING OR PLACING IN ROADWAYS.

3. MINIMUM COVER TO TOP OF ENVELPE SHALL BE 610mm (24") OR

AS OTHERWISE SPECIFIED IN SECTION 26 05 41.

4. PROVIDE MINIMUM 152mm (6") SPACE BETWEEN POWER AND

TELECOMMUNICATION DUCTS. INCREASE SIZE AS REQUIRED.

5. INNERDUCT QUANTITY AND SIZE AS INDICATED ON PLANS.

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o n e o e q u a rt e r in c h o th re e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com 205

SCALE: 1/8" = 1'-0"

E503

506-330

ANN ARBOR VAMC

OCT. 27, 2017

1W

SDT KEZ

ELECTRICAL DETAILS EXPAND 8TH FLOOR

MENTAL HEALTH

NOT TO SCALE6

EXIT SIGN MOUNTING - GYPBOARD CEILING

NOT TO SCALE3

GROUNDING BAR DETAIL

NOT TO SCALE11

CONDUIT EXPANSION JOINT CROSSING - EXPANSION

FITTING

NOT TO SCALE14

CONDUIT TRAPEZE MOUNTING DETAIL

NOT TO SCALE13

ROOF CONDUIT SUPPORT DETAIL

NOT TO SCALE5

EXIT SIGN MOUNTING - LAY-IN CEILING

NOT TO SCALE7

CONDUIT ROOF PENETRATION DETAIL

NOT TO SCALE2

DOWNLIGHT MOUNTING - GYPBOARD CEILING

NOT TO SCALE1

DOWNLIGHT MOUNTING - LAY-IN CEILING

NOT TO SCALE10

LUMINAIRE MOUNTING - GYPBOARD CEILING

NOT TO SCALE9

LUMINAIRE MOUNTING - LAY-IN CEILING

NOT TO SCALE4

RECEPTACLE ROOF MOUNTING DETAIL

NOT TO SCALE12

UNDERGROUND CONCRETE PULLBOX - PAVED AREAS

NOT TO SCALE8

DUCT BANK DETAILS

REVISIONS DATE

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

2-SPD TWO SPEED

VFD VARIABLE FREQUENCY DRIVE

RVS REDUCED VOLTAGE

STARTER TYPES:

FS FUSED SWITCH

NFS NON-FUSED SWITCH

MCP MOTOR CIRCUIT PROTECTOR

CB CIRCUIT BREAKER

COMBINATION DISCONNECT TYPES:

HOA HAND-OFF-AUTO SWITCH

RP RED (RUN) PILOT LIGHT

GP GREEN (POWER) PILOT LIGHT

0/0 ON-OFF SELECTOR SWITCH

S/S STOP-START PUSHBUTTONS

CONTROL DEVICES:

EC ELECTRICAL CONTRACTOR

MC MECHANICAL CONTRACTOR

GC GENERAL CONTRACTOR

TC TEMPERATURE CONTROL

OWN OWNER

ABBREVIATIONS:

1. INPUT AND OUTPUT CONDUCTORS TO AND FROM VFD'S SHALL BE INSTALLED IN SEPARATE RACEWAYS, INDEPENDENT FROM ANY OTHER CONDUCTORS, AND SHALL NOT PASS THRU ANY COMMON

WIREWAY OR RACEWAY.

NOTES:

LIGHTING FIXTURE SCHEDULE

GENERAL NOTES:

A. THE MANUFACTURER PRODUCT IDENTIFIED ABOVE MEETS THE SALIENT CHARACTERISTINCS OF THE SPECIFICATION. SUCH INFORMATION IS ONLY PROVIDED TO SHOW AN

EXAMPLE OF PRODUCTS WHICH MEET THE SPECIFICATIONS AND DO NOT, IN ANY WAY, LIMIT THE OFFERTORY FROM PROVIDING PRODUCTS FROM OTHER MANUFACTURES

WHICH MEET THE SALIENT CHARACTERISTICS AS IDENTIFIED IN THE SPECIFICATION.

B. CONTRACTOR SHALL REFER TO SPECIFICATIONS REGARDING PROVIDING ADDITIONAL SPARE LAMPS, LENSES, AND GLOBES.

C. SUBSTITUTE FIXTURES MUST BE SUBMITTED FOR APPROVAL 10 DAYS PRIOR TO BID SUBMISSION.

SCHEDULE NOTES:

1. EXISTING 2X4 LIGHT FIXTURES OF SAME STYLE WHICH WERE REMOVED AND SALVAGED MAY BE REUSED WHERE THIS FIXTURE TYPE IS SHOWN. ALL FIXTURES IN ANY GIVEN ROOM

SHALL EITHER BE NEW OR REUSED.

2. WITH ARROWS AS INDICATED ON PLAN.

3. DEDUCT ALTERNATE IF ALTERNATES ARE USED. REFERENCE ALTD-5.

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com 205

SCALE: 1/8" = 1'-0"

E601

506-330

ANN ARBOR VAMC

OCT. 27, 2017

1W

SDT KEZ

ELECTRICAL SCHEDULES EXPAND 8TH FLOOR

MENTAL HEALTH

TAG DESCRIPTION POWER VOLTAGE PHASE FEEDER DISCONNECTING MEANS DISC FURNISH/INSTALL NOTES

(i.e. EF-1) (i.e. Exhaust Fan #1) 831 VA 480 V 3 (i.e. 4#12+G-3/4"C) (i.e. PROVIDE 30A/3P FUSIBLE

DISCONNECT)

(i.e. DIV. 26 / DIV. 26)

1W-AC-1 CABINET UNIT HEATER 1500 VA 120 V 1 2#12+G-3/4"C PROVIDE 20A/1P DISCONNECT DIV. 23/ DIV. 23

1W-ACCH-1 AIR COOLED CHILLER 88124 VA 480 V 3 3#1/0+G-2"C VFD DIV. 26 / DIV. 26

1W-CHP-1A CHILLER PUMP 1A 6124 VA 208 V 3 3#10+G-3/4"C VFD DIV. 26 / DIV. 26

1W-CHP-1B CHILLER PUMP 1B 6124 VA 208 V 3 3#10+G-3/4"C VFD DIV. 26 / DIV. 26

1W-CUH-1 CABINET UNIT HEATER 3000 VA 120 V 1 2#12+G-3/4"C PROVIDE 20A/1P DISCONNECT DIV. 23/ DIV. 23

1W-EF-1 EXHAUST FAN 864 VA 120 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-5 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-6 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-7 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-8 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-14 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-15 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-16 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-17 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-18 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-19 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-20 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-21 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-22 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-23 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-24 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-25 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-26 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-27 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-29 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-30 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-31 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-32 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-33 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-34 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-36 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-37 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-38 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-39 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-40 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-41 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-42 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-43 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-44 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-45 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1W-FCU-46 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23

1WG-HWP-1A HOT WATER PUMP 1A 1441 VA 208 V 3 3#12+G-3/4"C VFD DIV. 26 / DIV. 26

1WG-HWP-1B HOT WATER PUMP 1B 1441 VA 208 V 3 3#12+G-3/4"C VFD DIV. 26 / DIV. 26

MARK TYPE MOUNTING REQUIREMENTS

MANUFACTURER

(BASIS OF

DESIGN) CATALOG SERIES VOLT WATT APPROVED ALTERNATE NOTE

A1 1X4 ARCHITECTURAL TROFFER -

GRID/FLANGE

RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, 22 GAUGE STEEL, 0-10V DIMMING, 90+CRI, 4000K, 90+LPW, 3100 INITIAL DELIVERED LUMEN (MIN) CREE CR14-31L-40K-10V 277 V 34 W ---

A2 2X2 ARCHITECTURAL TROFFER -

GRID/FLANGE

RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, 22 GAUGE STEEL, 0-10V DIMMING, 90+CRI, 4000K, 90+LPW, 2000 INITIAL DELIVERED LUMEN (MIN) CREE CR22-20L-40K-10V 277 V 22 W ---

A4 2X4 ARCHITECTURAL TROFFER -

GRID/FLANGE

RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, 22 GAUGE STEEL, 0-10V DIMMING, 90+CRI, 4000K, 100+LPW, 4000 INITIAL DELIVERED LUMEN (MIN) CREE CR24-40L-40K-10V 277 V 40 W --- 1

C1 2X2 LOW PROFILE LENSED TROFFER RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, SOLID ALUMINUM FRAME, 0-10V DIMMING, 90+CRI, 4000K, 100+LPW, 3400 INITIAL DELIVERED LUMEN (MIN) CREE FP22-34L-40K-10V 277 V 34 W ---

C2 2X4 LOW PROFILE LENSED TROFFER RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, SOLID ALUMINUM FRAME, 0-10V DIMMING, 90+CRI, 4000K, 100+LPW, 4000 INITIAL DELIVERED LUMEN (MIN) CREE FP24-40L-40K-10V 277 V 40 W ---

D1 6" LED DOWNLIGHT RECESSED SEMI-SPECULAR FINISH, 45 DEGREE CUT-OFF, DRIVER ACCESS THROUGH APRETURE, 0-10V DIMMING, 85+CRI, 4000K, 85+LPW, 1500 NOMINAL LUMENS (MIN) GOTHAM EVO-41/15-6AR-WD-MVOLT-EZ10 277 V 25 W ---

D2 6" LED DOWNLIGHT RECESSED SEMI-SPECULAR FINISH, 45 DEGREE CUT-OFF, DRIVER ACCESS THROUGH APRETURE, 0-10V DIMMING, 85+CRI, 4000K, 85+LPW, 3500 NOMINAL LUMENS (MIN) GOTHAM EVO-41/35-6AR-WD-MVOLT-EZ10 277 V 42 W ---

D3 6" LED DOWNLIGHT - DAMP LOCATION RECESSED REGRESSED NON-CONDUCTIVE TRIM, WHITE PAINTED FLANGE, DRIVER ACCESS THROUGH APRETURE, 85+CRI, 4000K, 85+LPW, 1500 NOMINAL LUMENS (MIN) GOTHAM EVO-40/15-6-DFR-MVOLT 277 V 25 W ---

F1 4' LED LENSED STRIPLIGHT SURFACE WHITE, STEEL, DIFFUSE LENS, 80+CRI, 4000K, 3000 NOMINAL LUMENS (MIN) LITHONIA ZL2N-L48-3000LM-MDD-MVOLT-40K-80CRI-WH 277 V 41 W ---

H2 2X4 SECURITY TROFFER RECESSED 12 GAUGE STEEL DOOR, 0.187+ CLEAR POLYCARBONATE OUTER LENS, PROVIDE SCREWDRIVER FOR TAMPERPROOF SCREWS, 0-10V DIMMING, 85+CRI, 4000K, 5000

NOMINAL DELIVERED LUMEN (MIN)

FAIL-SAFE FMR-S244-LD4-3LO-40-UNV-80-85-EDD-1-VRSD 277 V 110 W ---

P1 CONNECTED RING PENDANT PENDANT --- LIGHT ART LA2 CONNECTED RING - 8'-0" - 3000K - 3FORM VARIA

ECORESIN METALLICS WISP SILVER SHADE

277 V 173 W VOKSLYTE TANULED-PC-25'2"-48"-40K-

40K-SO-W-UNI

P2 CONNECTED RING PENDANT PENDANT --- LIGHT ART LA2 CONNECTED RING - 10'-0" - 3000K - 3FORM VARIA

ECORESIN METALLICS WISP SILVER WISP SILVER

SHADE

277 V 230 W VOKSLYTE TANULED-PC-31'5"-60"-40K-

40K-SO-W-UNI

P3 CONNECTED RING PENDANT PENDANT --- LIGHT ART LA2 CONNECTED RING - 12'-0" - 3000K - 3FORM VARIA

ECORESIN METALLICS WISP SILVER WISP SILVER

SHADE

277 V 288 W VOKSLYTE TANULED-PC-37'9"-72"-40K-

40K-SO-W-UNI

P4 2' PENDANT VARYING STEM

LENGHTS

--- LIGHT ART CASPER PENDANT - 24.5"H - SILVER CANOPY/

SILVER DRESS PLATE

277 V 15 W SPI PAVO INTERIOR PENDANT SIP11879

L11.4WC-24V 277V 3000K EPC

P5 4' PENDANT VARYING STEM

LENGHTS

--- LIGHT ART CASPER PENDANT - 48.5"H - SILVER CANOPY/

SILVER DRESS PLATE

277 V 32 W SPI PAVO INTERIOR PENDANT SIP11879

L26.7WC-24V 277V 3000K EPC

P6 6' PENDANT VARYING STEM

LENGHTS

--- LIGHT ART CASPER PENDANT - 72.5"H - SILVER CANOPY/

SILVER DRESS PLATE

277 V 49 W SPI PAVO INTERIOR PENDANT SIP11879

L41.9WC-24V 277V 3000K EPC

P7 11.75" DECORATIVE PENDANT PENDANT --- LIGHT ART CYLINDER PENDANT - 11.75H - 3FORM VARIA

ECORESIN METALLICS WISP SILVER WISP SILVER

SHADE - STYLE B

120 V 9 W BRUCK CAPTAIN 110-930-mc-IN-MP W/

LMP-TB1030022K1

P8 PENDANT LINEAR DIRECT/INDIRECT SUSPEND @ X'-X" AFF 0-10V DIMMING, 80+CRI, 4000K, 8000 LUMENS (MIN) CORELITE DSI-WS-2L40-1D-UNV-AC-48-JB-8-STD-W 277 V 50 W ---

R4 4' RECESSED SLOT RECESSED 2" ARPETURE, 0-10V DIMMING, 80+CRI, 4000K FINELITE HP-2 R-4'-S-840-F-277V-SC-VF 277 V 40 W ---

R8 12' RECESSED SLOT RECESSED 2" ARPETURE, 0-10V DIMMING, 80+CRI, 4000K FINELITE HP-2 R-8'-S-840-F-277V-SC-VF 277 V 120 W ---

R12 12' RECESSED SLOT RECESSED 2" ARPETURE, 0-10V DIMMING, 80+CRI, 4000K FINELITE HP-2 R-12'-S-840-F-277V-SC-VF 277 V 120 W ---

W1 DECORATIVE SCONCE WALL MT @ 6'-0" AFF --- LIGHT ART BOX SCONCE - 18"H - 3FORM WISP SILVER SHADE - 277 V 12 W MANNING LIGHTING IMAGES SCONCE

LB-380-1L10T35-BA-BA-CD(LUMICA SILVER

SPUN)-D0

W2 2' VANITY LIGHT WALL MT @ 6'-8" AFF 0-10V DIMMING, 82+CRI, 4000K, 2200 LUMENS (MIN) LITHONIA WL2-22L-MVOLT-EZ1-LP840 277 V 20 W ---

W4 4' VANITY LIGHT WALL MT @ 6'-8" AFF 0-10V DIMMING, 82+CRI, 4000K, 3000 LUMENS (MIN) LITHONIA WL4-30L-MVOLT-EZ1-LP840 277 V 30 W ---

X1 SINGLE FACE EXIT SIGN UNIVERSAL DIE-CAST ALUMINUM CONSTRUCTION, BRUSHED ALUMINUM FACEPLATE, RED LETTERS LITHONIA LQC-W1R 277 V 3 W --- 2

X2 DOUBLE FACE EXIT SIGN UNIVERSAL DIE-CAST ALUMINUM CONSTRUCTION, BRUSHED ALUMINUM FACEPLATE, RED LETTERS LITHONIA LQC-W2R 277 V 3 W --- 2

EXISTING PANEL. ESTIMATED EXISTING LOAD IS 62KVA (172 AMPS).

NOTES:

EST. DEMAND CURRENT: 34 A

CONNECTED CURRENT: 34 A

EST. DEMAND LOAD: 12249 VA

CONNECTED LOAD: 12249 VA

Motor 12249 VA 100.00% 12249 VA

LOAD CLASSIFICATION CONNECTED DEMAND FACTOR CALCULATED

PANEL TOTALS

Space -- -- 41 ... 42 -- -- Space

Space -- -- 39 ... 40 -- -- Space

Space -- -- 37 ... 38 -- -- Space

Space -- -- 35 ... 36 -- -- Space

Space -- -- 33 ... 34 -- -- Space

Space -- -- 31 ... 32 -- -- Space

Space -- -- 29 ... 30 -- -- Space

Space -- -- 27 ... 28 -- -- Space

Space -- -- 25 ... 26 -- -- Space

-- 2041 -- -- 23 ... 24 -- -- 2041 --

-- 2041 -- -- 21 ... 22 -- -- 2041 --

1W-CHP-1A 2041 3 35 A 19 ... 20 35 A 3 2041 1W-CHP-1B

-- -- -- 17 ... 18 -- -- Space

-- -- -- 15 ... 16 -- -- Space

CU-2 (EXIST) 3 150 A 13 ... 14 -- -- Space

-- -- -- 11 ... 12 20 A 1 S/F DAMPER

-- -- -- 9 ... 10 20 A 1 EXIST

AHU-1 (EXIST) 3 80 A 7 ... 8 20 A 1 10TH FL REC

-- -- -- 5 ... 6 -- -- --

-- -- -- 3 ... 4 -- -- --

AHU-2 (EXIST) 3 40 A 1 ... 2 80 A 3 CU-1

LOAD DESCRIPTION

LTS RCPTS MTRS OTHER

BKR

P AMP CIRCUIT

BKR

AMP P

OTHER MTRS RCPTS LTS

LOAD DESCRIPTION

SPECIAL:

A.I.C. RATING: 10,000 AMPS SYMMETRICAL

FEEDER: SEE ONE-LINE DIAGRAM MAIN DEVICE: 250 A MAIN CB

FED FROM: BUS AMPS: 400 AMPS

MOUNTING: SURFACE NEMA1 VOLTAGE: 208Y/120V / 3 ø / 4W

LOCATION: PENTHOUSE - PANEL TYPE:

PANELBOARD: 10B A/C

EXISTING PANEL

NOTES:

EST. DEMAND CURRENT: 8 A

CONNECTED CURRENT: 8 A

EST. DEMAND LOAD: 3044 VA

Receptacle 740 VA 100.00% 740 VA CONNECTED LOAD: 3044 VA

Motor 2304 VA 100.00% 2304 VA

LOAD CLASSIFICATION CONNECTED DEMAND FACTOR CALCULATED

PANEL TOTALS

Space -- -- 41 ... 42 -- -- --

Space -- -- 39 ... 40 30 A 2 Spare

Space -- -- 37 ... 38 20 A 1 Spare

Space -- -- 35 ... 36 -- -- --

Space -- -- 33 ... 34 30 A 2 Spare

31 ... 32 -- -- 312 --

29 ... 30 15 A 2 312 ACU-3

-- -- -- 27 ... 28

Spare 2 100 A 25 ... 26 20 A 1 Spare

23 24

Spare 1 20 A 21 ... 22

19 ... 20 20 A 1 Spare

Spare 1 20 A 17 ... 18 20 A 1 Spare

Spare 1 20 A 15 ... 16 20 A 1 Spare

Spare 1 20 A 13 ... 14 20 A 1 Spare

Spare 1 20 A 11 ... 12

Spare 1 20 A 9 ... 10 20 A 1 Spare

Spare 1 20 A 7 ... 8 20 A 1 560 REC DESK LOBBY B200

Spare 1 20 A 5 ... 6 20 A 1 1680 DOOR OPERATORS

SECURITY GATE 1 20 A 3 ... 4 20 A 1 Spare

POS COFFEE SHOP 180 1 20 A 1 ... 2 20 A 1 Spare

LOAD DESCRIPTION

LTS RCPTS MTRS OTHER

BKR

P AMP CIRCUIT

BKR

AMP P

OTHER MTRS RCPTS LTS

LOAD DESCRIPTION

SPECIAL:

A.I.C. RATING: 10,000 AMPS SYMMETRICAL

FEEDER: SEE ONE-LINE DIAGRAM MAIN DEVICE: 225 A MAIN CB

FED FROM: BUS AMPS: 225 AMPS

MOUNTING: SURFACE NEMA 1 VOLTAGE: 208Y/120V / 3 ø / 4W

LOCATION: Space BB122 PANEL TYPE:

PANELBOARD: CR1B-1

REVISIONS DATE

Revision 1 Date 1

P PP P P P

P P

P

P P

P P

P P

P P

P P

P P

P

P

P PP P P P P P P P P P

P P

PP P

P P

P P

P P

P

PP PPPP

P P

P P

P P

P P

P

P

P P

P P

P P

P PP P P P P P P P P P

P P

P

P PP P P P

P P

P P

P

P PP P P P

P PP P P

P P

P

P PP P P

P P

P P

P P

PP PPP

P P

P P

P P

P PP P P P P P

P

P PP P

P P

P

PP PP

P P

P

S S

S S

S S

S S

S S

S S

S

S SS

S

S S S S S S S S S S S S S S S S

P PP P

P

P

P P

P

P P

P P

S

S

S

S

WW

WW

WW

WW

F

S

F

N

N

WALL MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.

FLOOR MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.

CEILING MOUNTED WIRELESS ACCESS POINT (GFGI). (1) CAT

6A (CFCI).

W

FURNITURE TYPE VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.

F

PUBLIC ADDRESS SPEAKERS

TELECOMMUNICATIONS LEGEND

WALL MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

FLOOR MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

FURNITURE TYPE VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

F

ALTD-7

NURSE CALL DOME LIGHT

N NURSE CALL PULL CORD STATION

CORRIDOR

BB98

131 SF

COMM.2

BB77B

11 SF

COMM.1

BB77A

13 SF

INTERVIEW

BB91

55 SF

OFFICE PHYS SEC

BB80

104 SF

TRAINING/BREAK

BB93

309 SF

STAFF GYM

BB70

369 SF

STORAGE

BB78

141 SF

WOMEN'S SHOWER

BB95A

81 SF

WOMEN'S LOCKER

BB95

66 SF

ALCOVE

BB71A

33 SF

ADMIN

BB71

169 SF

TOILET

BB73

68 SF

HOLDING

BB92

54 SF

EVIDENCE

BB90

49 SF

STORAGE

BB93A

70 SF

ARMS OFFICE

BB72

143 SF

CORR.

BB97

257 SF

OFFICE TRAINING

BB85

160 SF

OFFICE DEPUTY

BB83

110 SF

OFFICE CHIEF

BB82

124 SF

OFFICE INVSTGTR

BB81

108 SF

BIOMED OFFICE

BB32

246 SF

OPEN OFFICE

BB96

394 SF

TOILET

BB75

66 SF

OFFICE EM. MGR.

BB76

130 SF

OFFICE

BB77

109 SF

ALCOVE

BB74A

56 SF

MEN'S LOCKER

BB94

175 SF

MEN'S SHOWER

BB94A

219 SF

CORR.

BB98B

67 SF

EXISTING COMM ROOM

BB26, SERVING AREA B

STAFF WAP (TYP)

STAFF WAP (TYP)

ALTD-2

GENERAL NOTE

1. CONTRACTOR SHALL SPACE INSTALL PA SPEAKERS

EVERY 20'. TERMINATE SPEAKERS TO EXISTING PA

SYSTEM.

2. WIRELESS ACCESS POINTS SHOWN ARE GFGI.

CONTRACTOR TO INSTALL CABLING BACK TO

CLOSEST IDF AND GOVERNMENT FURNISHED TILE

ENCLOSURE AT EACH WIRELESS ACCESS POINT

LOCATION.

3. CONTRACTOR TO USE EXISTING CABLE

SUPPORTING INFRASTRUCTURE (AS MUCH AS

POSSIBLE) TO SUPPORT NEW CABLE. IF EXISTING

PATHWAYS CANNOT SUPPORT NEW CABLING

PROVIDE 12'' X 6'' WIRE MESH CABLE TRAY FOR MAIN

HORIZONTAL PATHWAY RUNS. USE 2'' J-HOOKS

FROM CABLE TRAY TO OUTLET.

KEY NOTE #

1 CONTRACTOR TO TIE NURSE CALL DEVICES TO EXISTING VA

NURSE CALL SYSTEM. COORDINATE WITH VA FOR EQUIPMENT

TERMINATION LOCATION.

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: As indicated

TC100

506-330

ANN ARBOR VAMC

DS MK

TELECOMMUNICATIONS

AND SPECIAL SYSTEMS -

BASEMENT

EXPAND 8TH FLOOR

MENTAL HEALTH

3/32" = 1'-0"

NEW TELECOMMUNICATIONS AND

SPECIAL SYSTEMS FLOOR PLAN -

BASEMENT

195REVISIONS DATE

*M an it ow oc

*M an it ow oc

P PP

P

P P

P

P

P

P P

S S

S

S S

S S

S S

S

S

S S

S

S SS S S

S

S S

S

S SS S S S S S

S

S S

S

S S S

S SS

S S

PP PPPP

P P

P P

P

P P

P P

P

P P

P P

P

S

S

S W P

W P

S W P

W

W

W

S

S

S

CORRIDOR

B204

410 SF

COFFEE SHOP

B203

292 SF

LOBBY

B200

689 SF

WHEELCHAIR ALCOVE

B205

39 SF

WAITING

B202

78 SF

VESTIBULE

B201

108 SF

M

M

M

S M

S M

VOLUME

CONTROLLER FOR

MUSIC

WALL MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.

CEILING MOUNTED WIRELESS ACCESS POINT (GFGI). (1) CAT

6A (CFCI).

W

PUBLIC ADDRESS SPEAKERS

TELECOMMUNICATIONS LEGEND

CEILING MOUNTED WIRELESS ACCESS POINT PUBLIC (GFGI).

(1) CAT 6A (CFCI).

W

P

WALL MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

FLOOR MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

FURNITURE TYPE VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

F

ALTD-7

CEILING MOUNTED SPEAKER FOR MUSIC SYSTEMS

W

S M

WALL MOUNTED EXTERIOR SPEAKER FOR MUSIC SYSTEM

GENERAL NOTE

1. CONTRACTOR SHALL SPACE INSTALL PA SPEAKERS

EVERY 20'. TERMINATE SPEAKERS TO EXISTING PA

SYSTEM.

2. WIRELESS ACCESS POINTS SHOWN ARE GFGI.

CONTRACTOR TO INSTALL CABLING BACK TO

CLOSEST IDF AND GOVERNMENT FURNISHED TILE

ENCLOSURE AT EACH WIRELESS ACCESS POINT

LOCATION.

3. CONTRACTOR TO USE EXISTING CABLE

SUPPORTING INFRASTRUCTURE (AS MUCH AS

POSSIBLE) TO SUPPORT NEW CABLE. IF EXISTING

PATHWAYS CANNOT SUPPORT NEW CABLING

PROVIDE 12'' X 6'' WIRE MESH CABLE TRAY FOR MAIN

HORIZONTAL PATHWAY RUNS. USE 2'' J-HOOKS

FROM CABLE TRAY TO OUTLET.

KEY NOTE #

1 CONTROL EQUIPMENT FOR MUSIC SYSTEM

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: As indicated

TC101

506-330

ANN ARBOR VAMC

DS MK

TELECOMMUNICATIONS

AND SPECIAL SYSTEMS - 1ST

FLOOR

EXPAND 8TH FLOOR

MENTAL HEALTH

3/32" = 1'-0"

NEW TELECOMMUNICATIONS AND

SPECIAL SYSTEMS FLOOR PLAN - 1ST

FLOOR

196REVISIONS DATE

P

PP PP

P P

P

PP P

P P

P

P

P P

P P P

P P

P P

PP

P P

P P

P

P P

P

P

P PP

P

P P

P P

PP

P P

P

P P

P

P PP

P PP

P

PP P

P

P PP

P

P

P

PP

P P

P

P

P

P

PP

P

P PP P P

P

S

WW

WW

S

S

S

WW

S

WW

S

S S

WW

WWWWWW

STAIR

171 SF

ELECTRICAL

A850

2 SF

ELECTRIC

A847

23 SF

STAIR

196 SF

OFFICE

B805

138 SF

HAC

B806

32 SF

RESTROOM

C806

58 SF

RESTROOM

C807

58 SF

CONFERENCE/MEDIATION

C811

259 SF

STAIR

174 SF

STAIR

170 SF

MEN'S RESTROOM

A830

170 SF

WOMEN'S RESTROOM

A830A

140 SF

FELLOWS ROOM

A832

178 SF

ACOS

A837

110 SF

OFFICE

B804

119 SF

STAIR

174 SF

COMMUNICATIONS

A843A

42 SF

SERVICE ELEVATORS

A840

176 SF

FLOAT

A844

157 SF

UTILIZ. MGMT.

A841

355 SF

EXAM

A836

169 SF

OFFICE

B827

109 SF

OFFICE

B825

108 SF

OFFICE

B824

111 SF

CHIEF

B822a

130 SF

SHARED OFFICE

B821

184 SF

COMMUNICATIONS

B812

62 SF

BLUE TEAM

B808

346 SF

LARGE CONF.

B810

418 SF

SHARED OFFICE

B814

215 SF

TEAM ROOM

B815

320 SF

EEO PROGRAM MANAGER

C810

103 SF

OFFICE

C809

76 SF

FLOAT

A843

139 SF

SWING OFFICE

A842

150 SF

OFFICE

B826

115 SF

SECRETARY

B822

120 SF

OFFICE

B803

124 SF

OFFICE

B802

138 SF

OFFICE

B801

149 SF

OFFICE

B820

104 SF

COPY

B807

67 SF

PIMS

A838

151 SF

CACS & INFROMATICS

A839

540 SF

COPY/BREAK

A840a

201 SF

OFFICE

B828

103 SF

CORRIDOR

645 SF

CARE CORD.

B818

373 SF

KITCHENETTE

B816

96 SF

SWING OFFICE

A848

151 SF

Q. MGMT.

A846

921 SF

PASSAGE

A846F

697 SF

TEAM ROOM

A846A

144 SF

CORRIDOR

1032 SF

CORRIDOR

B820

168 SF

EXISTING COMM

ROOM SERVING

AREA A

EXISTING COMM

ROOM SERVING

AREAS B AND C

STAFF WAP (TYP)

PASSAGE

A846D

94 SF

PASSAGE

A846C

124 SF

PASSAGE

B823

48 SF

PASSAGE

A846B

133 SF

ALTD-10

ALTD-9

WALL MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.

FLOOR MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.

CEILING MOUNTED WIRELESS ACCESS POINT (GFGI). (1) CAT 6A

(CFCI).

W

PUBLIC ADDRESS SPEAKERS

TELECOMMUNICATIONS LEGEND

WALL MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

FLOOR MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

FURNITURE TYPE VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.

F

ALTD-7

GENERAL NOTE

1. CONTRACTOR SHALL SPACE INSTALL PA SPEAKERS

EVERY 20'. TERMINATE SPEAKERS TO EXISTING PA

SYSTEM.

2. WIRELESS ACCESS POINTS SHOWN ARE GFGI.

CONTRACTOR TO INSTALL CABLING BACK TO CLOSEST

IDF AND GOVERNMENT FURNISHED TILE ENCLOSURE AT

EACH WIRELESS ACCESS POINT LOCATION.

3. CONTRACTOR TO USE EXISTING CABLE SUPPORTING

INFRASTRUCTURE (AS MUCH AS POSSIBLE) TO

SUPPORT NEW CABLE. IF EXISTING PATHWAYS CANNOT

SUPPORT NEW CABLING PROVIDE 12'' X6'' WIRE MESH

CABLE TRAY FOR MAIN HORIZONTAL PATHWAY RUNS.

USE 2'' J-HOOKS FROM CABLE TRAY TO OUTLET.

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

A

B

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

OCT 27, 2017

SCALE: As indicated

TC108

506-330

ANN ARBOR VAMC

DS MK

TELECOMMUNICATIONS

AND SPECIAL SYSTEMS - 8TH

FLOOR

EXPAND 8TH FLOOR

MENTAL HEALTH

3/32" = 1'-0"

NEW TELECOMMUNICATIONS AND

SPECIAL SYSTEMS FLOOR PLAN - 8TH

197REVISIONS DATE

4-PR UTP CAT 6A PLENUM CABLE TO

VOICE/DATA OUTLETS AND STAFF WAP

OUTLETS

CAT 6A CABLES TO

GUEST WAP OUTLETS

EXISTING MULTIPAIR

CAT 3 CABLE

4-PR UTP CAT 5e

PLENUM BLUE CABLE

TO VOICE OUTLETS

78 INCHES AFF

KEY NOTE #

1 EXISTING EQUIPMENT RACK

GENERAL NOTE

1. INSTALLATION CONTRACTOR IS RESPONSIBLE FOR ALL SEISMIC

LOAD CALCULATIONS FOR CABLE TRAYS, CONDUITS AND OTHER

PATHWAYS IN THE CEILING IN ACCORDANCE WITH DIVISION 27

SEPECIFICATIONS.

2. ALL SLEEVES HAVE BUSHINGS & ARE FIRESTOPPED WITH PUTTY

AFTER INSTALLATION.

3. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING

TELECOM EQUIPMENT AND PLACEMENT OF NEW TELECOM

EQUIPMENT IN EACH COMM ROOM.

4. CAT 6A COLORS ARE AS FOLLOWS: BLUE (DATA AND CAT 5e

VOICE CABLES), YELLOW (WAP IN STAFF AREAS), PINK (WAP IN

GUEST AREAS).

2 48-PORT CAT 6A PATCH PANEL (CFCI), QTY AS REQUIRED.

3 110 TELEPHONE BLOCK (CFCI)

4 EXISTING 110 TELEPHONE BLOCK

5 EXISTING TELECOM EQUIPMENT

6 2 RMU HORIZONTAL MANAGER (CFCI)

SAFETY WIRE TO STRUCTURE

SPEAKER ENCLOSURE W/

INTEGRAL MTD. CLAMPS

CEILING TILE OR GWB

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: As indicated

TC401

506-330

ANN ARBOR VAMC

DS MK

TELECOMMUNICATIONS

ROOM DETAILS

EXPAND 8TH FLOOR

MENTAL HEALTH

N.T.S.

RACK ELEVATION-TYPICAL

N.T.S.

TELEPHONE BLOCK WALL

ELEVATION-TYPICAL

N.T.S.

CEILING MOUNTED VOICE SPEAKER

198REVISIONS DATE

XX-XXX

XX-XXX

x;1 x;24 x;1 x;2

XX-UNXXX

1 2

XX - UN XXX - S 03

TR NAME

UN-CLASSIFIED CABLE

WORK AREA ID

JACK ID IE, 01, 02, 03 ETC.

JACK TYPE: V-VOICE D-DATA S-SPARE T-TELEVISION

TYPICAL COMM ROOM

CLIENT SWITCH (PROVIDED BY VA)

48 PORT CAT 6A PATCH PANEL

4 PAIR UTP

CAT6A CABLE

4 PAIR UTP CAT6A PATCH CORD

WORK AREA ID

WORK AREA ID

TYPICAL 4 PORT WALL FACE PLATE

JACK ID IE, 01, 02, 03 ETC.

JACK TYPE: V-VOICE

D-DATA

S-SPARE

TR NAME

IE, IA, IB, ETC.

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: N.T.S.

TC402

506-330

ANN ARBOR VAMC

DS MK

TELECOM WIRING DETAIL -

DATA

EXPAND 8TH FLOOR

MENTAL HEALTH

N.T.S.

TELECOM WIRING DETAIL - DATA

199REVISIONS DATE

W B L

B L W

O R W

W O R

W G R

W B R

G R W

B R W x;1 x;25

W G R x;1

B L W

W B L

O R W

W O R

W B R

G R W

B R W

S L W

W S L

B L R

R B L

V L V I

B K B R

S L R

R O R

R G R

O R R

G R R

B R R

R B R

R S L

B K B L

B L B K

B K O R

B K G R

O R B K

G R B K

B R B K

B K S L

Y B L

S L B K

B L Y

Y O R

O R Y

G R Y

Y B R

Y G R

B R Y

S L Y

Y S L

V I- V L

V I- S L

V I- O R

O R V I

V I- G R

V I- B R

G R V I

B R V I x;25

S L V I

110 CONNECTOR BLOCK 110 CONNECTOR BLOCK

XX-UNXXX

TYPICAL COMM ROOM

INTERMEDIATE CROSS CONNECT (TYPICAL OF 25 PAIRS)

EXISTING MULTIPAIR UTP

CAT 3 PLENUM CABLE

4 PAIR UTP CAT 5e CABLE

HORIZONTAL CABLE IDENTIFICATION

TYPICAL 4 PORT WALL FACE PLATE

JACK ID

IE, 01, 02, 03 ETC.

JACK TYPE: V-VOICE D-DATA

S-SPARE T-TELEVISION

TR NAME

IE, IA, IB, ETC.

UN-CLASSIFIED WA

WORK AREA ID

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: N.T.S.

TC403

506-330

ANN ARBOR VAMC

DS MK

TELECOM WIRING DETAIL -

VOICE

EXPAND 8TH FLOOR

MENTAL HEALTH

N.T.S.

TELECOM WIRING DETAIL - VOICE

200REVISIONS DATE

NCP

N D

DATA BUS

CONNECTION TO

EXISTING

SECURITY PANEL

CAT 6 (TYP)

NETWORK SWITCH (BY OTHERS)

COMM CLOSET (TYP) TYPICAL FLOOR

SCP

KP MS CR PB

NS

IDS

IC

MS

CAT 6

IC

DS

INDOOR/OUTDOOR CAT 6

ADMIN OFFICE ROOM BB71SECURITY GATE

TO

TELEPHONE

SYSTEM

COMM CLOSET (TYP) TYPICAL FLOOR

AMP SS S S

AMP SS S S

M M M M

EXISTING

VOLUME CONTROLLER

AT INFORMATION DESK

CONTACT CLOSURE

INTERFACE

COMM CLOSET

(TYP) TYPICAL FLOOR

CAT 6A AND CAT5e (TYP.)

D A T A W W

P

COMM CLOSET (TYP) TYPICAL FLOOR

DATA BUS

CONNECTION

TO EXISTING

HOSPITAL

NURSE CALL

SYSTEM

EXISTING

NURSE CALL

PANEL

CAT6

NURSE CALL DOME LIGHT

NURSE CALL PULL CORD STATION

GENERAL NOTE

1. ALL WIRING SHALL BE PER MANUFACTURER'S RECOMMENDATIONS. RISER

DIAGRAM IS SCHEMATIC FOR EXACT QUANTITY OF DEVICES SEE FLOOR

PLANS. ELECTRICAL CONTRACTOR TO COORDINATE WITH PAGING VENDOR

FOR ALL MISCELLANEOUS PAGING DEVICES, INCLUDING WIRING AND

RACEWAY. REFER TO SPECIFICATIONS.

2. PAGING VENDOR SHALL SUPPLY ANY ADDITIONAL POWER SUPPLIES,

EMERGENCY BACKUP BATTERIES OR ANY HARDWARE NEEDED TO PROVIDE

A COMPLETE PAGING SYSTEM.

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: As indicated

TC601

506-330

ANN ARBOR VAMC

DS MK

SPECIAL SYSTEMS RISER

DIAGRAMS

EXPAND 8TH FLOOR

MENTAL HEALTH

N.T.S.

SECURITY SYSTEM

N.T.S.

PAGING SYSTEM AND MUSIC SYSTEM

N.T.S.

TELECOM SYSTEM

N.T.S.

NURSE CALL SYSTEM

201REVISIONS DATE

P PP P P P

P

P

P P

P P

P P

P P

P P

P P

P

P

P PP P P P P P P P P P

P P

PP P

P P

P P

P P

P

PP PPPP

P P

P P

P P

P P

P

P

P P

P P

P P

P PP P P P P P P P P P

P P

P

P PP P P P

P P

P P

P

P PP P P P

P PP P P

P P

P

P PP P P

P P

P P

P P

PP PPP

P P

P P

P P

P PP P P P P P

P

P PP P

P P

P

PP PP

P P

P

S S

S S

S S

S S

S S

S S

S

S SS

S

S S S S S S S S S S S S S S S S

P PP P

P

P

P P

P

P P

P P

F

F

F

K P

C R

C R

C R

MS

M S

KP

CR

F

CR

F

C R

C R

F

DR

CORRIDOR

BB98

131 SF

COMM.2

BB77B

11 SF

COMM.1

BB77A

13 SF

INTERVIEW

BB91

55 SF

OFFICE PHYS SEC

BB80

104 SF

TRAINING/BREAK

BB93

309 SF

STAFF GYM

BB70

369 SF

STORAGE

BB78

141 SF

WOMEN'S SHOWER

BB95A

81 SF

WOMEN'S LOCKER

BB95

66 SF

ALCOVE

BB71A

33 SF

ADMIN

BB71

169 SF

TOILET

BB73

68 SF

HOLDING

BB92

54 SF

EVIDENCE

BB90

49 SF

STORAGE

BB93A

70 SF

ARMS OFFICE

BB72

143 SF

CORR.

BB97

257 SF

OFFICE TRAINING

BB85

160 SF

OFFICE DEPUTY

BB83

110 SF

OFFICE CHIEF

BB82

124 SF

OFFICE INVSTGTR

BB81

108 SF

BIOMED OFFICE

BB32

246 SF

OPEN OFFICE

BB96

394 SF

TOILET

BB75

66 SF

OFFICE EM. MGR.

BB76

130 SF

OFFICE

BB77

109 SF

ALCOVE

BB74A

56 SF

MEN'S LOCKER

BB94

175 SF

MEN'S SHOWER

BB94A

219 SF

CORR.

BB98B

67 SF

EXISTING COMM ROOM

BB26. LOCATION OF

EXISTING SECURITY

DISTRIBUTION EQUIPMENT

ALTD-2

IC

MS

KEY NOTE #

1 CAMERA SHALL INCLUDE BUILT IN AUDIO. COORDINATE

CAMERA PALCEMENT TO ENSURE VIEW OF POLICE SUBJECT.

GENERAL NOTE

1. CONTRACTOR TO USE EXISTING SECURITY CABLE SUPPORTING

INFRASTRUCTURE AS MUCH AS POSSIBLE. PROVIDE NEW AS

NEEDED.

2. NEW CAMERAS SHOWN SHALL TERMINATE TO NEW IP VIDEO

MANAGEMENT SYSTEM UNDER SEPARATE PROJECT.

CONTRACTOR TO COORDINATE WITH VA SECURITY FOR

TERMINATION LOCATION.

3. UNLESS OTHERWISE NOTED, SECURITY DEVICES SHOWN SHALL

TERMINATE TO EXISTING SECURITY PANELS INSIDE COMM ROOM

BB26. PROVIDE ADDITIONAL SECURITY DISTRIBUTION

EQUIPMENT AS NEEDED. COORDINATE WITH VA POLICE FOR

EXACT TERMINATION LOCATIONS.

2 EXISTING VIDEO SURVEILLANCE EQUIPMENT TO REMAIN.

CONTRACTOR TO PROTECT EQUIPMENT DURING RENOVATION.

3 EXISTING SECURITY ALARM EQUIPMENT OT REMAIN.

CONTRACTOR TO PROTECT EQUIPMENT DRUING RENOVATION.

EQUIPMENT LEGEND

CR WALL MOUNTED CARD READER

CEILING MOUNTED GLASS BREAK SENSORGB

SECURITY PANIC BUTTONPB

CEILING MOUNTED FIXED IP CAMERAF

CEILING MOUNTED SECURITY MOTION SENSORMS

INTRUSION DETECTION SYSTEM KEYPADKP

CEILING MOUNTED 180 DEGREE FIXED IP CAMERAF

DOOR RELEASE BUTTONDR

INTERCOM MASTER STATION (AIPHONE IX-MV OR EQUAL)IC

MS

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: As indicated

TY100

506-330

ANN ARBOR VAMC

DS MK

SECURITY FLOOR PLAN -

BASEMENT

EXPAND 8TH FLOOR

MENTAL HEALTH

3/32" = 1'-0"

NEW SECURITY FLOOR PLAN -

BASEMENT

202REVISIONS DATE

M an it ow oc

M an it ow oc

P PP

P

P P

P

P

P

P P

S S

S

S S

S S

S S

S

S

S S

S

S SS S S

S

S S

S

S SS S S S S S

S

S S

S

S S S

S SS

S S

PP PPPP

P P

P P

P

P P

P P

P

P P

P P

P

CR

GB

GB

GB

GB

GB

PB

P B

F

F

F

F

F

CORRIDOR

B204

410 SF

COFFEE SHOP

B203

292 SF

LOBBY

B200

689 SF

WHEELCHAIR ALCOVE

B205

39 SF

WAITING

B202

78 SF

VESTIBULE

B201

108 SF

EXISTING COMM ROOM

SERVING AREA B

GENERAL NOTE

1. CONTRACTOR TO USE EXISTING SECURITY CABLE SUPPORTING

INFRASTRUCTURE AS MUCH AS POSSIBLE. PROVIDE NEW AS

NEEDED.

2. NEW CAMERAS SHOWN SHALL TERMINATE TO NEW IP VIDEO

MANAGEMENT SYSTEM UNDER SEPARATE PROJECT.

CONTRACTOR TO COORDINATE WITH VA SECURITY FOR

TERMINATION LOCATION.

3. UNLESS OTHERWISE NOTED, SECURITY DEVICES SHOWN SHALL

TERMINATE TO A NEW SECURITY PANELS (CFCI) INSIDE EXISTING

COMM ROOM B143. SECURITY PANELS MUST BE COMPATIBLE

WITH EXISTING HOSPITAL ACCESS CONTROL AND INTRUSION

DETECTION SYSTEMS.

EQUIPMENT LEGEND

CR WALL MOUNTED CARD READER

CEILING MOUNTED GLASS BREAK SENSORGB

SECURITY PANIC BUTTONPB

CEILING MOUNTED FIXED IP CAMERAF

CEILING MOUNTED SECURITY MOTION SENSORMS

CEILING MOUNTED FIXED IP CAMERAF

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: As indicated

TY101

506-330

ANN ARBOR VAMC

DS MK

SECURITY FLOOR PLAN - 1ST

FLOOR

EXPAND 8TH FLOOR

MENTAL HEALTH

3/32" = 1'-0"

NEW SECURITY FLOOR PLAN - 1ST

203REVISIONS DATE

TO CONTROL PANEL

1'' CONDUIT

JUNCTION BOX (SECURED SIDE)

PROVIDE TAMPER SWITCH

3/4'' CONDUIT

FINISHED CEILING

6''RECESSED DOOR

CONTACT

ELECTRIC POWER TRANSFER

(PROVIDED BY DIV. 8)

12'' MAX

ELECTRIFIED MORTISE LOCKSET

WITH INTEGRATED MICRO-SWITCH

REX (PROVIDED BY DIV. 8)

CARD READER (UNSECURED SIDE)

CL

SECURE SIDE

UNSECURE SIDE

FINISHED CEILING

CL

SECURE SIDE

UNSECURE SIDE

12'' MAX

6''

TO CONTROL PANEL

1'' CONDUIT

RECESSED DOOR

CONTACTS

ELECTRIC POWER TRANSFER

(PROVIDED BY DIV. 8)

CARD READER

(UNSECURED SIDE)

ELECTRIFIED

MORTISE LOCKSET

WITH INTEGRATED

MICRO-SWITCH REX

(PROVIDED BY DIV. 8)

3/4'' CONDUIT

NOTES:

A. COORDINATE WITH DIV. 8 FOR

EXACT HARDWARE/CONDUIT

REQUIREMENTS.

B. ALIGN CONDUIT WITH MAGNETIC

CONTACT SWITCH LOCATION.

COORDINATE WITH DOOR & FRAME

SUPPLIER.

DOOR DETAIL NOTES:

1. JUNCTION BOXES AND PULL BOXES SHALL BE SIZED

ACCORDINGLY WITH COVER PLATE PAINTED BLUE UNLESS

OTHERWISE INDICATED. SECURE COVER PLATE WITH TAMPER

RESISTANT SCREWS.

2. CONDUIT FROM DOOR DEVICE TO JUNCTION BOX ABOVE DOOR

SHALL BE 3/4'' EMT UNLESS NOTED OTHERWISE.

3. POSITION JUNCTION BOX AS NOT TO INTERFERE WITH EXISTING

CONDUIT OF OTHER EXISTING SYSTEMS.

4. WHERE NO FINISHED CEILING EXIST, JUNCTION BOXES OVER

DOORS SHALL BE PLACED AT LEAST 9'' FROM BOTTOM OF BOX

TO TOP OF DOOR AS SPACE PERMITS.

5. DOOR TYPE DETAILS ARE SHOWN FOR EQUIPMENT LAYOUT AND

WIRING REQUIRED. MAY NEED TO BE REVISED TO FIT SPECIFIC

DOOR APPLICATIONS.

6. DUAL DOOR CONTACT ON DOOR SHALL BE WIRED AS SINGLE

ZONE WITH END OF LINE RESISTOR ONLY ON THE LAST DOOR

CONTACT.

7. WIRING FOR ACCESS CONTROL AND IDS SHALL BE ROUTED IN

WALLS WHERE POSSIBLE. CONDUIT SHALL BE INSTALLED ON

SECURE SIDE OF WALL WHERE APPLICABLE.

8. UNLESS OTHERWISE NOTED, FOR CMU WALLS, SURFACE MOUNT

EQUIPMENT AND CONDUIT. FOR HOLLOW WALLS, RUN CABLE IN

CONDUIT IN INTERIOR. FOR ARMORED CABLE, PROVIDE AS PART

OF DOOR CONTACT, PENETRATE WALL ABOVE DOOR CONTACT

WITH A SINGLE GANG BOX AND MATCHING SINGLE HOLE COVER

PLATE. RUN CABLE IN WALL TO ABOVE CEILING, THEN CONNECT

TO ABOVE DOOR JUNCTION BOX WITH SUPPLIED CONNECTORS.

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Department of Veterans

68 East Michigan Ave.

Battle Creek, MI 49017

P: 269.224.3182 www.wbkengineering.com

451 Hungerford Dr. 4th Floor

Rockville, MD 20850

P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com

1W

Oct 27, 2017

SCALE: As indicated

TY401

506-330

ANN ARBOR VAMC

DS MK

DEVICE/DOOR DETAILS EXPAND 8TH FLOOR

MENTAL HEALTH

N.T.S.

SINGLE ACS DOOR WITH ELECTRIFIED

LOCKSET

N.T.S.

DOUBLE ACS DOOR WITH ELECTRIFIED

LOCKSET

204REVISIONS DATE

REINFORCED CONCRETE SLAB

CONDUIT BACK TO

SECURITY EQUIPMENT

JUNCTION BOX

CEILING BRACKET

1/2'' 2''

IP DOME CAMERA

SUSPENDED CEILING

MOUNTING PLATE

8 27/32''

NOTES:

1. ARMORFLEX CONDUIT TO BE PROVIDED BY THE CONTRACTOR

2. ALL CAMERA ASSEMBLIES SHALL BE FIRMLY ATTACHED TO SUBSTANTIAL

WALL SURFACES OR STRUCTURAL MEMEBERS. CAMERA ASSEMBLY

INSTALLATION DIRECTLY TO DRYWALL SURFACES SHALL NOT BE

ACCEPTABLE.

CONDUIT BACK TO SECURITY EQUIPMENT

GYPSUM

WALL BOARD

4.52''

Ø 3.58''

CONDUIT BACK

TO SECURITY

EQUIPMENT

GYPSUM WALL

BOARD

4.52''

Ø 3.58''

NOTES:

1. ALL CAMERA ASSEMBLIES SHALL BE

FIRMLY ATTACHED TO SUBSTANTIAL WALL

SURFACES OR STRUCTURAL MEMBERS.

NOTES:

1. MOUNT CAMERA ASSEMBLY AT MOST

DESIRABLE HEIGHT ABOVE FINISHED

FLOOR TO AVOID OBSTRUCTIONS AND TO

PROVIDE THE FIELD-OF-VIEW DESIRED.

2. ALL CAMERA ASSEMBLIES SHALL BE

FIRMLY ATTACHED TO SUBSTANTIAL WALL

SURFACES OR STRUCTURAL MEMBERS.

N

1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com

616 361 2664 OFFICE 616 361 1493 FAX

architecture +engineering

SEVEN

GENERATIONS

4664 Campus Drive, Suite 101

Kalamazoo, MI 49008

P: 269.927.0144 www.7GenAE.com

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 91

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANTS ARCHITECT/ENGINEERS

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR LOCATION

PROJECT TITLE:

DATE: CHECKED: DRAWN:

PROJECT NUMBER:

BUILDING NUMBER:

DRAWING NUMBER:

DWG. ___ OF ___

7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG

Office of

Construction and Facilities

Management

VA FORM 08-6231

o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o

6 "

Dep…

This is the start of the file's text. The full file is on GovTribe.