36C25018B0817-011.pdf
PDF 7 MB Posted
- Attached to
- Expand 8th Floor - Mental Health 506-330
- Solicitation number
- 36C25018B0817
About this file
36C25018B0817 S02 - Drawings VOL2-Part 6 - 506-330.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25018B0817-0005000.docx | DOCX document | |
| 36C25018B0817-0005001.pdf | ||
| 36C25018B0817-0005003.pdf | ||
| 36C25018B0817-0005002.pdf | ||
| 36C25018B0817-0004000.docx | DOCX document | |
| 36C25018B0817-0003001.docx | DOCX document | |
| 36C25018B0817-0003000.docx | DOCX document | |
| 36C25018B0817-0002000.docx | DOCX document | |
| 36C25018B0817-0001000.docx | DOCX document | |
| 36C25018B0817-005.pdf | ||
| 36C25018B0817-003.pdf | ||
| 36C25018B0817-007.pdf | ||
| 36C25018B0817-008.pdf | ||
| 36C25018B0817-012.pdf | ||
| 36C25018B0817-001.docx | DOCX document | |
| 36C25018B0817-010.pdf | ||
| 36C25018B0817-013.docx | DOCX document | |
| 36C25018B0817-016.docx | DOCX document | |
| 36C25018B0817-009.pdf | ||
| 36C25018B0817-006.pdf | ||
| 36C25018B0817-014.pdf | ||
| 36C25018B0817-015.pdf | ||
| 36C25018B0817-002.pdf | ||
| 36C25018B0817-004.pdf | ||
| 36C25018B0817-000.docx | DOCX document |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CEILING HANGER WIRE
DRYWALL CEILING
CROSS TEE. TYP.
DRYWALL
CEILING CROSS
TEE. TYP.
GYPSUM
BOARD
HANGER WIRE AND MOUNTING CHANNEL
ATTACHED TO STRUCTURE REFER TO
SPECIFICATION SECTION 26 51 00
INTEGRAL GALVANIZED LIPPED
STEEL MOUNTING CHANNEL
JUNCTION BOX
LOCKING SQUARE
WASHER & NUT
6.35mm (1/4") SCREW
CEILING
MAIN BEAM.
WIRE TIE THROUGH
MOUNTING CHANNEL
& CROSS BEAM, TYP.
FIXTURE WHIP FROM JUNCTION
BOX (1829mm (6') LONG MAX)
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
(2 m m
(4
2m m
(1")
25mm
(1")
25mm
(1")
25mm
(2")
51mm
(1 1/2") TYP
38mm
(1 m m
(5 /8 m m
6.35mm
(1/4") DIA.
MOUNTING
HOLES TYP. OF
(4)
BASE CLAMP/
BRACKET
9.52mm (3/8")
DIA. HOLE TYP.
OF (6)
9.52mm (3/8") x 16mm (5/8") HEX
HEAD BOLT
9.52mm (3/8") LOCK WASHER
9.52mm (3/8") FLAT WASHER & 9.52mm (3/8") LOCK WASHER
6.35mm
(1/4") THICK
CU BAR
(2'-0") MIN
610mm
6.35mm (1/4")
DIA. HOLE TYP
OF (8)
SECTION
STEEL EXPANSION
ANCHOR
INSULATOR
9.52mm (3/8") FLAT WASHER
GENERAL NOTES
1. ALL HARDWARE SHALL BE STAINLESS STEEL.
2. PROVIDE 1 MOUNTING POINT PER 305mm(12") OF BAR LENGTH.
3. HOLES MAY BE ADDED IF REQUIRED.
(3'-0") MAX
SEISMIC OR EXPANSION
JOINT. FIELD VERIFY
ACTUAL CONDITIONS &
LOCATIONS.FLOOR OR ROOF
STRUCTURE. FIELD VERIFY
ACTUAL CONDITIONS, TYP.
STRUCTURAL MEMBER
(BEAM, JOIST, ETC.), TYP.
JUNCTION BOX,
TYP (SIZE AS REQUIRED)
CONDUIT
TRAPEZE PER
SD260533-03,
TYP.
914mm
BEAM
CLAM,
TYP.
CONDUIT,
TYP.
EXPANSION FITTING
WITH BONDING JUMPER
INTEGRAL GALVANIZED LIPPED
STEEL MOUNTING CHANNEL
STEEL EXPANSION
ANCHOR
JUNCTION BOX
(SIZE AS REQUIRED)
CONDUIT FITTING
SPRING NUT
HEAD
INSULATING
BUSHING
PROVIDE EXTRA CABLE TO
MAKE COMPLETE LOOP
AROUND BOX PERIMETER
GENERAL NOTES:
1. INSTALLATION IS ACCEPTABLE ALTERNATE TO DETAIL SD260533-01.
2. INSTALLATION IS REQUIRED FOR CONDUIT 76mm (3") AND LARGER.
LENGTH AS REQUIRED
CONDUIT CLAMP.
SIZE AS REQUIRED
INTEGRAL
GALVANIZED
LIPPED STEEL
MOUNTING
CHANNEL
REFER TO PLANS FOR
QUANTITY & SIZE OF
CONDUITS
LOCKING SQUARE
WASHER & LOCKNUT
9.52mm (3/8") MIN
GALVANIZED THREADED
ROD, TYP.
WASHER &
LOCKNUT
INTEGRAL
GALVANIZED
LIPPED STEEL
MOUNTING
CHANNEL
GENERAL NOTES:
1. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL
LONGER THAN 915mm (36") SHALL BE INSTALLED WITH A
CENTER SUPPORT ROD.
2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED
METHOD PER SPECIFICATION 26 05 33, RACEWAY AND BOXES
FOR ELECTRICAL SYSTEMS. FIELD VERIFY EXACT
CONDITIONS.
3. FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER TO
SPECIFICATION SECTION 13 05 41, SEISMIC RESTRAINT
REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS.
CONDUIT CLAMP.
SIZE AS REQUIRED
INTEGRAL GALVANIZED
LIPPED STEEL
MOUNTING CHANNEL
REFER TO PLANS
FOR QUANTITY &
SIZE OF CONDUITS
LOCKING
SQUARE WASHER
& LOCKNUT
9.52mm (3/8") MIN
GALVANIZED THREADED
ROD, TYP.
UV-INHIBITED POLYCARBONATE
OR HIGH-DENSITY
POLYPROPYLENE PLASTIC
BLOCK, LENGTH AS REQUIRED
CEILING HANGER WIRE
ARCHITECTURAL
CEILING GRID
ARCHITECTURAL
CEILING GRID
ACOUSTICAL
CEILING TILE
(TYP)
HANGER WIRE AND MOUNTING CHANNEL
ATTACHED TO STRUCTURE REFER TO
SPECIFICATION SECTION 26 51 00
INTEGRAL GALVANIZED LIPPED
STEEL MOUNTING CHANNEL
JUNCTION BOX
LOCKING SQUARE
WASHER & NUT
6.35mm (1/4") SCREW
ARCHITECTURAL
CEILING GRID
WIRE TIE THROUGH
MOUNTING CHANNEL
& CROSS BEAM, TYP.
FIXTURE WHIP FROM JUNCTION
BOX (1829mm (6') LONG MAX)
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
PREFABRICATED RUBBER
BOOT CAP WITH GRADUATED
STEPS & WEATHER-PROOF
PRESSURE SEAL TO COLLAR
SEALANT AT PENETRATION
TO MEMBRANE JUNCTURE
BY ROOFING CONTRACTOR
MULTIPLE MEMBRANE STRIPPING
PLIES FEATHERED AT FIELD OF
ROOF BY ROOFING CONTRACTOR.
PRIME FLANGE BEFORE STRIPPING.
PREFABRICATED FORMED 1.52mm (0.06")
THICK ALUMINUM FLASHING
ROUND COLLAR WITH MIN. 76mm (3")
WIDE FLANGE. ATTACH TO ROOF PER
MANUFACTURER'S INSTRUCTIONS
CONDUIT CLAMP. SIZE AS
REQUIRED
BATT INSULATION
ROOF MEMBRANE
WATER CUT-OFF
MASTIC COMPATIBLE
WITH ROOF MEMBRANE
STAINLESS CLAMP, TYP.
9.52mm (3/8") MIN
GALVANIZED
THREADED ROD, TYP.
SEAL-OFF
FITTING,
TYP.
ROOF
STEEL
EXPANSION
ANCHOR
INTEGRAL
GALVANIZED LIPPED
STEEL MOUNTING
CHANNEL
CONDUIT,
TYP.
CONDUIT
CLAMP. SIZE
AS REQUIRED
LOCKING
SQUARE
WASHER &
LOCKNUT
GENERAL NOTES:
1. MAINTAIN A MINIMUM CLEARANCE OF 305mm (12") ON ALL SIDES OF ROOF
PENETRATION FROM CALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE
PROPER FLASHING.
2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.
3. VERIFY ROOF & STRUCTURAL SYSTEM WITH ARCHITECT.
4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO ENSURE
PROPER METHODS & MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.
CEILING HANGER
WIRE, TYP.
RECESSED CAN
LUMINAIRE
REFER TO
SCHEDULE.
CEILING MAIN
BEAM
GYPSUM
BOARD (TYP)
WIRE TIE OR SCREW
BAR HANGER TO
CROSS BEAM TYP.
LUMINAIRE
BAR HANGERS
LUMINAIRE SUSPENSION WIRES
REFER TO SPECIFICATION SECTION 26 51 00
CEILING
CROSS BEAM
RECESSED CAN
LUMINAIRE
CEILING BEAM
FIXTURE WHIP FROM
JUNCTION BOX
(1829mm (6') LONG MAX)
GENERAL NOTES:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
CEILING HANGER
WIRE, TYP.
RECESSED CAN
LUMINAIRE
ARCHITECTURAL
CEILING GRID
WIRE TIE OR SCREW BAR
HANGER TARCHITECTURAL
CEILING GRID TYP.
LUMINAIRE
BAR HANGERS
LUMINAIRE SUSPENSION WIRE
REFER TO SPECIFICATION
SECTION 26 51 00.
ACOUSTICAL
CEILING TILE (TYP)
RECESSED CAN
LUMINAIRE
ARCHITECUTRAL
CEILING GRID
FIXTURE WHIP FROM
JUNCTION BOX
(1829mm (6') LONG MAX)
GENERAL NOTES:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING RECOMMENDED MOUNTING HARDWARE
LUMINAIRE
SUSPENSION WIRES
REFER TO
SPECIFICATION
SECTION 26 51 00
3 TWIST MINIMUM
(TYP)
FIXTURE WHIP FROM
JUNCTION BOX
(1829mm (6') LONG MAX.)
CEILING MAIN BEAM
GYPSUM BOARD (TYP)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE MANUFACTURER'S
MOUNTING HARDWARE
REFER TO SPECIFICATION
SECTION 26 51 00
CEILING CROSS BEAM
GYPSUM BOARD
CEILING CROSS BEAM
LUMINAIRE.
REFER TO
SCHEDULE
DRYWALL BORDER
GENERAL NOTES:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
LUMINAIRE
SUSPENSION WIRES
REFER TO
SPECIFICATION
SECTION 26 51 00
3 TWIST MINIMUM
(TYP)
FIXTURE WHIP
FROM JUNCTION BOX
(1829mm (6') LONG MAX.)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE MANUFACTURER'S
MOUNTING HARDWARE
REFER TO SPECIFICATION
SECTION 26 51 00
ACOUSTICAL CEILING
TILE (TYP)
ARCHITECTURAL
CEILING GRID
LUMINAIRE.
REFER TO
SCHEDULE
GENERAL NOTES:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
(1 2"
M
A X m m
(1 8"
M
A X m m
CAST METAL
"WHILE-IN-USE"
WP COVER(S) &
RECEPTACLE(S).
CAST METAL, 2-GANG,
NEMA 3R JUNCTION BOX
WITH THREADED HUBS.
RIGID STEEL CONDUIT
FOR WIRING
A
A
SECTION "A-A"
ELEVATION
RIGID STEEL CONDUIT
FOR SUPPORT PER
N.E.C. ART. 314
ROOF PENETRATION AND
CONDUIT SUPPORT PER
SD260533-05
(4) CONCRETE BRICKS
51mmx203mmx406mm (2"x8"x16")
CONDUIT(S) WITH BELL ENDS
(TYP). SIZE, QUANTITY AND
WIRING AS INDICATED ON PLANS
CLEAN 19mm (3/4")
CRUSHED ROCK
FINISHED PAVING
V A
R
IE
S (1
2"
PULLBOX (SEE SPECIFICATIONS)
LINE SIDES OF
EXCAVATION
WITH 13.6 KG (30 LBS.)
FELT PAPER
(12")
5m m
305mm
PLASTIC SPACER
INNERDUCT,
SEE NOTE 5
DUCT [SIZE AS
INDICATED ON DWGS.] 6-WAY DUCT LINE 4-WAY DUCT LINE
2-WAY DUCT LINE
TIE WIRE
(3")
(3")
76mm
(3 m m (3 m m
76mm
(3")
76mm
(3 m m
(3 m m
(3 m m
(3")
(3")
76mm
(3")
76mm76mm
(3
(3 m m m m m m
(3
76mm
(3")
76mm (3")
76mm (3")
152mm
(6")(SEE NOTE 4)
(T Y
P
GENERAL NOTES:
1. CONCRETE SHALL BE 2000 P.S.I. @ 28 DAYS, OR AS SPECIFIED.
2. PROVIDE #4 REINFORCING RODS ON TOP AND BOTTOM OF DUCTS
WHEN CROSSING OR PLACING IN ROADWAYS.
3. MINIMUM COVER TO TOP OF ENVELPE SHALL BE 610mm (24") OR
AS OTHERWISE SPECIFIED IN SECTION 26 05 41.
4. PROVIDE MINIMUM 152mm (6") SPACE BETWEEN POWER AND
TELECOMMUNICATION DUCTS. INCREASE SIZE AS REQUIRED.
5. INNERDUCT QUANTITY AND SIZE AS INDICATED ON PLANS.
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o n e o e q u a rt e r in c h o th re e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com 205
SCALE: 1/8" = 1'-0"
E503
506-330
ANN ARBOR VAMC
OCT. 27, 2017
1W
SDT KEZ
ELECTRICAL DETAILS EXPAND 8TH FLOOR
MENTAL HEALTH
NOT TO SCALE6
EXIT SIGN MOUNTING - GYPBOARD CEILING
NOT TO SCALE3
GROUNDING BAR DETAIL
NOT TO SCALE11
CONDUIT EXPANSION JOINT CROSSING - EXPANSION
FITTING
NOT TO SCALE14
CONDUIT TRAPEZE MOUNTING DETAIL
NOT TO SCALE13
ROOF CONDUIT SUPPORT DETAIL
NOT TO SCALE5
EXIT SIGN MOUNTING - LAY-IN CEILING
NOT TO SCALE7
CONDUIT ROOF PENETRATION DETAIL
NOT TO SCALE2
DOWNLIGHT MOUNTING - GYPBOARD CEILING
NOT TO SCALE1
DOWNLIGHT MOUNTING - LAY-IN CEILING
NOT TO SCALE10
LUMINAIRE MOUNTING - GYPBOARD CEILING
NOT TO SCALE9
LUMINAIRE MOUNTING - LAY-IN CEILING
NOT TO SCALE4
RECEPTACLE ROOF MOUNTING DETAIL
NOT TO SCALE12
UNDERGROUND CONCRETE PULLBOX - PAVED AREAS
NOT TO SCALE8
DUCT BANK DETAILS
REVISIONS DATE
MECHANICAL EQUIPMENT CONNECTION SCHEDULE
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
2-SPD TWO SPEED
VFD VARIABLE FREQUENCY DRIVE
RVS REDUCED VOLTAGE
STARTER TYPES:
FS FUSED SWITCH
NFS NON-FUSED SWITCH
MCP MOTOR CIRCUIT PROTECTOR
CB CIRCUIT BREAKER
COMBINATION DISCONNECT TYPES:
HOA HAND-OFF-AUTO SWITCH
RP RED (RUN) PILOT LIGHT
GP GREEN (POWER) PILOT LIGHT
0/0 ON-OFF SELECTOR SWITCH
S/S STOP-START PUSHBUTTONS
CONTROL DEVICES:
EC ELECTRICAL CONTRACTOR
MC MECHANICAL CONTRACTOR
GC GENERAL CONTRACTOR
TC TEMPERATURE CONTROL
OWN OWNER
ABBREVIATIONS:
1. INPUT AND OUTPUT CONDUCTORS TO AND FROM VFD'S SHALL BE INSTALLED IN SEPARATE RACEWAYS, INDEPENDENT FROM ANY OTHER CONDUCTORS, AND SHALL NOT PASS THRU ANY COMMON
WIREWAY OR RACEWAY.
NOTES:
LIGHTING FIXTURE SCHEDULE
GENERAL NOTES:
A. THE MANUFACTURER PRODUCT IDENTIFIED ABOVE MEETS THE SALIENT CHARACTERISTINCS OF THE SPECIFICATION. SUCH INFORMATION IS ONLY PROVIDED TO SHOW AN
EXAMPLE OF PRODUCTS WHICH MEET THE SPECIFICATIONS AND DO NOT, IN ANY WAY, LIMIT THE OFFERTORY FROM PROVIDING PRODUCTS FROM OTHER MANUFACTURES
WHICH MEET THE SALIENT CHARACTERISTICS AS IDENTIFIED IN THE SPECIFICATION.
B. CONTRACTOR SHALL REFER TO SPECIFICATIONS REGARDING PROVIDING ADDITIONAL SPARE LAMPS, LENSES, AND GLOBES.
C. SUBSTITUTE FIXTURES MUST BE SUBMITTED FOR APPROVAL 10 DAYS PRIOR TO BID SUBMISSION.
SCHEDULE NOTES:
1. EXISTING 2X4 LIGHT FIXTURES OF SAME STYLE WHICH WERE REMOVED AND SALVAGED MAY BE REUSED WHERE THIS FIXTURE TYPE IS SHOWN. ALL FIXTURES IN ANY GIVEN ROOM
SHALL EITHER BE NEW OR REUSED.
2. WITH ARROWS AS INDICATED ON PLAN.
3. DEDUCT ALTERNATE IF ALTERNATES ARE USED. REFERENCE ALTD-5.
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com 205
SCALE: 1/8" = 1'-0"
E601
506-330
ANN ARBOR VAMC
OCT. 27, 2017
1W
SDT KEZ
ELECTRICAL SCHEDULES EXPAND 8TH FLOOR
MENTAL HEALTH
TAG DESCRIPTION POWER VOLTAGE PHASE FEEDER DISCONNECTING MEANS DISC FURNISH/INSTALL NOTES
(i.e. EF-1) (i.e. Exhaust Fan #1) 831 VA 480 V 3 (i.e. 4#12+G-3/4"C) (i.e. PROVIDE 30A/3P FUSIBLE
DISCONNECT)
(i.e. DIV. 26 / DIV. 26)
1W-AC-1 CABINET UNIT HEATER 1500 VA 120 V 1 2#12+G-3/4"C PROVIDE 20A/1P DISCONNECT DIV. 23/ DIV. 23
1W-ACCH-1 AIR COOLED CHILLER 88124 VA 480 V 3 3#1/0+G-2"C VFD DIV. 26 / DIV. 26
1W-CHP-1A CHILLER PUMP 1A 6124 VA 208 V 3 3#10+G-3/4"C VFD DIV. 26 / DIV. 26
1W-CHP-1B CHILLER PUMP 1B 6124 VA 208 V 3 3#10+G-3/4"C VFD DIV. 26 / DIV. 26
1W-CUH-1 CABINET UNIT HEATER 3000 VA 120 V 1 2#12+G-3/4"C PROVIDE 20A/1P DISCONNECT DIV. 23/ DIV. 23
1W-EF-1 EXHAUST FAN 864 VA 120 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-5 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-6 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-7 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-8 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-14 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-15 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-16 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-17 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-18 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-19 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-20 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-21 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-22 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-23 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-24 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-25 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-26 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-27 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-29 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-30 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-31 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-32 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-33 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-34 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-36 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-37 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-38 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-39 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-40 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-41 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-42 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-43 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-44 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-45 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1W-FCU-46 FAN COIL UNIT 208 VA 277 V 1 2#12+G-3/4"C . DIV. 23/ DIV. 23
1WG-HWP-1A HOT WATER PUMP 1A 1441 VA 208 V 3 3#12+G-3/4"C VFD DIV. 26 / DIV. 26
1WG-HWP-1B HOT WATER PUMP 1B 1441 VA 208 V 3 3#12+G-3/4"C VFD DIV. 26 / DIV. 26
MARK TYPE MOUNTING REQUIREMENTS
MANUFACTURER
(BASIS OF
DESIGN) CATALOG SERIES VOLT WATT APPROVED ALTERNATE NOTE
A1 1X4 ARCHITECTURAL TROFFER -
GRID/FLANGE
RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, 22 GAUGE STEEL, 0-10V DIMMING, 90+CRI, 4000K, 90+LPW, 3100 INITIAL DELIVERED LUMEN (MIN) CREE CR14-31L-40K-10V 277 V 34 W ---
A2 2X2 ARCHITECTURAL TROFFER -
GRID/FLANGE
RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, 22 GAUGE STEEL, 0-10V DIMMING, 90+CRI, 4000K, 90+LPW, 2000 INITIAL DELIVERED LUMEN (MIN) CREE CR22-20L-40K-10V 277 V 22 W ---
A4 2X4 ARCHITECTURAL TROFFER -
GRID/FLANGE
RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, 22 GAUGE STEEL, 0-10V DIMMING, 90+CRI, 4000K, 100+LPW, 4000 INITIAL DELIVERED LUMEN (MIN) CREE CR24-40L-40K-10V 277 V 40 W --- 1
C1 2X2 LOW PROFILE LENSED TROFFER RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, SOLID ALUMINUM FRAME, 0-10V DIMMING, 90+CRI, 4000K, 100+LPW, 3400 INITIAL DELIVERED LUMEN (MIN) CREE FP22-34L-40K-10V 277 V 34 W ---
C2 2X4 LOW PROFILE LENSED TROFFER RECESSED DRYWALL GRID AND AND LAY IN CEILING OPTIONS, SOLID ALUMINUM FRAME, 0-10V DIMMING, 90+CRI, 4000K, 100+LPW, 4000 INITIAL DELIVERED LUMEN (MIN) CREE FP24-40L-40K-10V 277 V 40 W ---
D1 6" LED DOWNLIGHT RECESSED SEMI-SPECULAR FINISH, 45 DEGREE CUT-OFF, DRIVER ACCESS THROUGH APRETURE, 0-10V DIMMING, 85+CRI, 4000K, 85+LPW, 1500 NOMINAL LUMENS (MIN) GOTHAM EVO-41/15-6AR-WD-MVOLT-EZ10 277 V 25 W ---
D2 6" LED DOWNLIGHT RECESSED SEMI-SPECULAR FINISH, 45 DEGREE CUT-OFF, DRIVER ACCESS THROUGH APRETURE, 0-10V DIMMING, 85+CRI, 4000K, 85+LPW, 3500 NOMINAL LUMENS (MIN) GOTHAM EVO-41/35-6AR-WD-MVOLT-EZ10 277 V 42 W ---
D3 6" LED DOWNLIGHT - DAMP LOCATION RECESSED REGRESSED NON-CONDUCTIVE TRIM, WHITE PAINTED FLANGE, DRIVER ACCESS THROUGH APRETURE, 85+CRI, 4000K, 85+LPW, 1500 NOMINAL LUMENS (MIN) GOTHAM EVO-40/15-6-DFR-MVOLT 277 V 25 W ---
F1 4' LED LENSED STRIPLIGHT SURFACE WHITE, STEEL, DIFFUSE LENS, 80+CRI, 4000K, 3000 NOMINAL LUMENS (MIN) LITHONIA ZL2N-L48-3000LM-MDD-MVOLT-40K-80CRI-WH 277 V 41 W ---
H2 2X4 SECURITY TROFFER RECESSED 12 GAUGE STEEL DOOR, 0.187+ CLEAR POLYCARBONATE OUTER LENS, PROVIDE SCREWDRIVER FOR TAMPERPROOF SCREWS, 0-10V DIMMING, 85+CRI, 4000K, 5000
NOMINAL DELIVERED LUMEN (MIN)
FAIL-SAFE FMR-S244-LD4-3LO-40-UNV-80-85-EDD-1-VRSD 277 V 110 W ---
P1 CONNECTED RING PENDANT PENDANT --- LIGHT ART LA2 CONNECTED RING - 8'-0" - 3000K - 3FORM VARIA
ECORESIN METALLICS WISP SILVER SHADE
277 V 173 W VOKSLYTE TANULED-PC-25'2"-48"-40K-
40K-SO-W-UNI
P2 CONNECTED RING PENDANT PENDANT --- LIGHT ART LA2 CONNECTED RING - 10'-0" - 3000K - 3FORM VARIA
ECORESIN METALLICS WISP SILVER WISP SILVER
SHADE
277 V 230 W VOKSLYTE TANULED-PC-31'5"-60"-40K-
40K-SO-W-UNI
P3 CONNECTED RING PENDANT PENDANT --- LIGHT ART LA2 CONNECTED RING - 12'-0" - 3000K - 3FORM VARIA
ECORESIN METALLICS WISP SILVER WISP SILVER
SHADE
277 V 288 W VOKSLYTE TANULED-PC-37'9"-72"-40K-
40K-SO-W-UNI
P4 2' PENDANT VARYING STEM
LENGHTS
--- LIGHT ART CASPER PENDANT - 24.5"H - SILVER CANOPY/
SILVER DRESS PLATE
277 V 15 W SPI PAVO INTERIOR PENDANT SIP11879
L11.4WC-24V 277V 3000K EPC
P5 4' PENDANT VARYING STEM
LENGHTS
--- LIGHT ART CASPER PENDANT - 48.5"H - SILVER CANOPY/
SILVER DRESS PLATE
277 V 32 W SPI PAVO INTERIOR PENDANT SIP11879
L26.7WC-24V 277V 3000K EPC
P6 6' PENDANT VARYING STEM
LENGHTS
--- LIGHT ART CASPER PENDANT - 72.5"H - SILVER CANOPY/
SILVER DRESS PLATE
277 V 49 W SPI PAVO INTERIOR PENDANT SIP11879
L41.9WC-24V 277V 3000K EPC
P7 11.75" DECORATIVE PENDANT PENDANT --- LIGHT ART CYLINDER PENDANT - 11.75H - 3FORM VARIA
ECORESIN METALLICS WISP SILVER WISP SILVER
SHADE - STYLE B
120 V 9 W BRUCK CAPTAIN 110-930-mc-IN-MP W/
LMP-TB1030022K1
P8 PENDANT LINEAR DIRECT/INDIRECT SUSPEND @ X'-X" AFF 0-10V DIMMING, 80+CRI, 4000K, 8000 LUMENS (MIN) CORELITE DSI-WS-2L40-1D-UNV-AC-48-JB-8-STD-W 277 V 50 W ---
R4 4' RECESSED SLOT RECESSED 2" ARPETURE, 0-10V DIMMING, 80+CRI, 4000K FINELITE HP-2 R-4'-S-840-F-277V-SC-VF 277 V 40 W ---
R8 12' RECESSED SLOT RECESSED 2" ARPETURE, 0-10V DIMMING, 80+CRI, 4000K FINELITE HP-2 R-8'-S-840-F-277V-SC-VF 277 V 120 W ---
R12 12' RECESSED SLOT RECESSED 2" ARPETURE, 0-10V DIMMING, 80+CRI, 4000K FINELITE HP-2 R-12'-S-840-F-277V-SC-VF 277 V 120 W ---
W1 DECORATIVE SCONCE WALL MT @ 6'-0" AFF --- LIGHT ART BOX SCONCE - 18"H - 3FORM WISP SILVER SHADE - 277 V 12 W MANNING LIGHTING IMAGES SCONCE
LB-380-1L10T35-BA-BA-CD(LUMICA SILVER
SPUN)-D0
W2 2' VANITY LIGHT WALL MT @ 6'-8" AFF 0-10V DIMMING, 82+CRI, 4000K, 2200 LUMENS (MIN) LITHONIA WL2-22L-MVOLT-EZ1-LP840 277 V 20 W ---
W4 4' VANITY LIGHT WALL MT @ 6'-8" AFF 0-10V DIMMING, 82+CRI, 4000K, 3000 LUMENS (MIN) LITHONIA WL4-30L-MVOLT-EZ1-LP840 277 V 30 W ---
X1 SINGLE FACE EXIT SIGN UNIVERSAL DIE-CAST ALUMINUM CONSTRUCTION, BRUSHED ALUMINUM FACEPLATE, RED LETTERS LITHONIA LQC-W1R 277 V 3 W --- 2
X2 DOUBLE FACE EXIT SIGN UNIVERSAL DIE-CAST ALUMINUM CONSTRUCTION, BRUSHED ALUMINUM FACEPLATE, RED LETTERS LITHONIA LQC-W2R 277 V 3 W --- 2
EXISTING PANEL. ESTIMATED EXISTING LOAD IS 62KVA (172 AMPS).
NOTES:
EST. DEMAND CURRENT: 34 A
CONNECTED CURRENT: 34 A
EST. DEMAND LOAD: 12249 VA
CONNECTED LOAD: 12249 VA
Motor 12249 VA 100.00% 12249 VA
LOAD CLASSIFICATION CONNECTED DEMAND FACTOR CALCULATED
PANEL TOTALS
Space -- -- 41 ... 42 -- -- Space
Space -- -- 39 ... 40 -- -- Space
Space -- -- 37 ... 38 -- -- Space
Space -- -- 35 ... 36 -- -- Space
Space -- -- 33 ... 34 -- -- Space
Space -- -- 31 ... 32 -- -- Space
Space -- -- 29 ... 30 -- -- Space
Space -- -- 27 ... 28 -- -- Space
Space -- -- 25 ... 26 -- -- Space
-- 2041 -- -- 23 ... 24 -- -- 2041 --
-- 2041 -- -- 21 ... 22 -- -- 2041 --
1W-CHP-1A 2041 3 35 A 19 ... 20 35 A 3 2041 1W-CHP-1B
-- -- -- 17 ... 18 -- -- Space
-- -- -- 15 ... 16 -- -- Space
CU-2 (EXIST) 3 150 A 13 ... 14 -- -- Space
-- -- -- 11 ... 12 20 A 1 S/F DAMPER
-- -- -- 9 ... 10 20 A 1 EXIST
AHU-1 (EXIST) 3 80 A 7 ... 8 20 A 1 10TH FL REC
-- -- -- 5 ... 6 -- -- --
-- -- -- 3 ... 4 -- -- --
AHU-2 (EXIST) 3 40 A 1 ... 2 80 A 3 CU-1
LOAD DESCRIPTION
LTS RCPTS MTRS OTHER
BKR
P AMP CIRCUIT
BKR
AMP P
OTHER MTRS RCPTS LTS
LOAD DESCRIPTION
SPECIAL:
A.I.C. RATING: 10,000 AMPS SYMMETRICAL
FEEDER: SEE ONE-LINE DIAGRAM MAIN DEVICE: 250 A MAIN CB
FED FROM: BUS AMPS: 400 AMPS
MOUNTING: SURFACE NEMA1 VOLTAGE: 208Y/120V / 3 ø / 4W
LOCATION: PENTHOUSE - PANEL TYPE:
PANELBOARD: 10B A/C
EXISTING PANEL
NOTES:
EST. DEMAND CURRENT: 8 A
CONNECTED CURRENT: 8 A
EST. DEMAND LOAD: 3044 VA
Receptacle 740 VA 100.00% 740 VA CONNECTED LOAD: 3044 VA
Motor 2304 VA 100.00% 2304 VA
LOAD CLASSIFICATION CONNECTED DEMAND FACTOR CALCULATED
PANEL TOTALS
Space -- -- 41 ... 42 -- -- --
Space -- -- 39 ... 40 30 A 2 Spare
Space -- -- 37 ... 38 20 A 1 Spare
Space -- -- 35 ... 36 -- -- --
Space -- -- 33 ... 34 30 A 2 Spare
31 ... 32 -- -- 312 --
29 ... 30 15 A 2 312 ACU-3
-- -- -- 27 ... 28
Spare 2 100 A 25 ... 26 20 A 1 Spare
23 24
Spare 1 20 A 21 ... 22
19 ... 20 20 A 1 Spare
Spare 1 20 A 17 ... 18 20 A 1 Spare
Spare 1 20 A 15 ... 16 20 A 1 Spare
Spare 1 20 A 13 ... 14 20 A 1 Spare
Spare 1 20 A 11 ... 12
Spare 1 20 A 9 ... 10 20 A 1 Spare
Spare 1 20 A 7 ... 8 20 A 1 560 REC DESK LOBBY B200
Spare 1 20 A 5 ... 6 20 A 1 1680 DOOR OPERATORS
SECURITY GATE 1 20 A 3 ... 4 20 A 1 Spare
POS COFFEE SHOP 180 1 20 A 1 ... 2 20 A 1 Spare
LOAD DESCRIPTION
LTS RCPTS MTRS OTHER
BKR
P AMP CIRCUIT
BKR
AMP P
OTHER MTRS RCPTS LTS
LOAD DESCRIPTION
SPECIAL:
A.I.C. RATING: 10,000 AMPS SYMMETRICAL
FEEDER: SEE ONE-LINE DIAGRAM MAIN DEVICE: 225 A MAIN CB
FED FROM: BUS AMPS: 225 AMPS
MOUNTING: SURFACE NEMA 1 VOLTAGE: 208Y/120V / 3 ø / 4W
LOCATION: Space BB122 PANEL TYPE:
PANELBOARD: CR1B-1
REVISIONS DATE
Revision 1 Date 1
P PP P P P
P P
P
P P
P P
P P
P P
P P
P P
P
P
P PP P P P P P P P P P
P P
PP P
P P
P P
P P
P
PP PPPP
P P
P P
P P
P P
P
P
P P
P P
P P
P PP P P P P P P P P P
P P
P
P PP P P P
P P
P P
P
P PP P P P
P PP P P
P P
P
P PP P P
P P
P P
P P
PP PPP
P P
P P
P P
P PP P P P P P
P
P PP P
P P
P
PP PP
P P
P
S S
S S
S S
S S
S S
S S
S
S SS
S
S S S S S S S S S S S S S S S S
P PP P
P
P
P P
P
P P
P P
S
S
S
S
WW
WW
WW
WW
F
S
F
N
N
WALL MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.
FLOOR MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.
CEILING MOUNTED WIRELESS ACCESS POINT (GFGI). (1) CAT
6A (CFCI).
W
FURNITURE TYPE VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.
F
PUBLIC ADDRESS SPEAKERS
TELECOMMUNICATIONS LEGEND
WALL MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
FLOOR MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
FURNITURE TYPE VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
F
ALTD-7
NURSE CALL DOME LIGHT
N NURSE CALL PULL CORD STATION
CORRIDOR
BB98
131 SF
COMM.2
BB77B
11 SF
COMM.1
BB77A
13 SF
INTERVIEW
BB91
55 SF
OFFICE PHYS SEC
BB80
104 SF
TRAINING/BREAK
BB93
309 SF
STAFF GYM
BB70
369 SF
STORAGE
BB78
141 SF
WOMEN'S SHOWER
BB95A
81 SF
WOMEN'S LOCKER
BB95
66 SF
ALCOVE
BB71A
33 SF
ADMIN
BB71
169 SF
TOILET
BB73
68 SF
HOLDING
BB92
54 SF
EVIDENCE
BB90
49 SF
STORAGE
BB93A
70 SF
ARMS OFFICE
BB72
143 SF
CORR.
BB97
257 SF
OFFICE TRAINING
BB85
160 SF
OFFICE DEPUTY
BB83
110 SF
OFFICE CHIEF
BB82
124 SF
OFFICE INVSTGTR
BB81
108 SF
BIOMED OFFICE
BB32
246 SF
OPEN OFFICE
BB96
394 SF
TOILET
BB75
66 SF
OFFICE EM. MGR.
BB76
130 SF
OFFICE
BB77
109 SF
ALCOVE
BB74A
56 SF
MEN'S LOCKER
BB94
175 SF
MEN'S SHOWER
BB94A
219 SF
CORR.
BB98B
67 SF
EXISTING COMM ROOM
BB26, SERVING AREA B
STAFF WAP (TYP)
STAFF WAP (TYP)
ALTD-2
GENERAL NOTE
1. CONTRACTOR SHALL SPACE INSTALL PA SPEAKERS
EVERY 20'. TERMINATE SPEAKERS TO EXISTING PA
SYSTEM.
2. WIRELESS ACCESS POINTS SHOWN ARE GFGI.
CONTRACTOR TO INSTALL CABLING BACK TO
CLOSEST IDF AND GOVERNMENT FURNISHED TILE
ENCLOSURE AT EACH WIRELESS ACCESS POINT
LOCATION.
3. CONTRACTOR TO USE EXISTING CABLE
SUPPORTING INFRASTRUCTURE (AS MUCH AS
POSSIBLE) TO SUPPORT NEW CABLE. IF EXISTING
PATHWAYS CANNOT SUPPORT NEW CABLING
PROVIDE 12'' X 6'' WIRE MESH CABLE TRAY FOR MAIN
HORIZONTAL PATHWAY RUNS. USE 2'' J-HOOKS
FROM CABLE TRAY TO OUTLET.
KEY NOTE #
1 CONTRACTOR TO TIE NURSE CALL DEVICES TO EXISTING VA
NURSE CALL SYSTEM. COORDINATE WITH VA FOR EQUIPMENT
TERMINATION LOCATION.
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: As indicated
TC100
506-330
ANN ARBOR VAMC
DS MK
TELECOMMUNICATIONS
AND SPECIAL SYSTEMS -
BASEMENT
EXPAND 8TH FLOOR
MENTAL HEALTH
3/32" = 1'-0"
NEW TELECOMMUNICATIONS AND
SPECIAL SYSTEMS FLOOR PLAN -
BASEMENT
195REVISIONS DATE
*M an it ow oc
*M an it ow oc
P PP
P
P P
P
P
P
P P
S S
S
S S
S S
S S
S
S
S S
S
S SS S S
S
S S
S
S SS S S S S S
S
S S
S
S S S
S SS
S S
PP PPPP
P P
P P
P
P P
P P
P
P P
P P
P
S
S
S W P
W P
S W P
W
W
W
S
S
S
CORRIDOR
B204
410 SF
COFFEE SHOP
B203
292 SF
LOBBY
B200
689 SF
WHEELCHAIR ALCOVE
B205
39 SF
WAITING
B202
78 SF
VESTIBULE
B201
108 SF
M
M
M
S M
S M
VOLUME
CONTROLLER FOR
MUSIC
WALL MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.
CEILING MOUNTED WIRELESS ACCESS POINT (GFGI). (1) CAT
6A (CFCI).
W
PUBLIC ADDRESS SPEAKERS
TELECOMMUNICATIONS LEGEND
CEILING MOUNTED WIRELESS ACCESS POINT PUBLIC (GFGI).
(1) CAT 6A (CFCI).
W
P
WALL MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
FLOOR MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
FURNITURE TYPE VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
F
ALTD-7
CEILING MOUNTED SPEAKER FOR MUSIC SYSTEMS
W
S M
WALL MOUNTED EXTERIOR SPEAKER FOR MUSIC SYSTEM
GENERAL NOTE
1. CONTRACTOR SHALL SPACE INSTALL PA SPEAKERS
EVERY 20'. TERMINATE SPEAKERS TO EXISTING PA
SYSTEM.
2. WIRELESS ACCESS POINTS SHOWN ARE GFGI.
CONTRACTOR TO INSTALL CABLING BACK TO
CLOSEST IDF AND GOVERNMENT FURNISHED TILE
ENCLOSURE AT EACH WIRELESS ACCESS POINT
LOCATION.
3. CONTRACTOR TO USE EXISTING CABLE
SUPPORTING INFRASTRUCTURE (AS MUCH AS
POSSIBLE) TO SUPPORT NEW CABLE. IF EXISTING
PATHWAYS CANNOT SUPPORT NEW CABLING
PROVIDE 12'' X 6'' WIRE MESH CABLE TRAY FOR MAIN
HORIZONTAL PATHWAY RUNS. USE 2'' J-HOOKS
FROM CABLE TRAY TO OUTLET.
KEY NOTE #
1 CONTROL EQUIPMENT FOR MUSIC SYSTEM
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: As indicated
TC101
506-330
ANN ARBOR VAMC
DS MK
TELECOMMUNICATIONS
AND SPECIAL SYSTEMS - 1ST
FLOOR
EXPAND 8TH FLOOR
MENTAL HEALTH
3/32" = 1'-0"
NEW TELECOMMUNICATIONS AND
SPECIAL SYSTEMS FLOOR PLAN - 1ST
FLOOR
196REVISIONS DATE
P
PP PP
P P
P
PP P
P P
P
P
P P
P P P
P P
P P
PP
P P
P P
P
P P
P
P
P PP
P
P P
P P
PP
P P
P
P P
P
P PP
P PP
P
PP P
P
P PP
P
P
P
PP
P P
P
P
P
P
PP
P
P PP P P
P
S
WW
WW
S
S
S
WW
S
WW
S
S S
WW
WWWWWW
STAIR
171 SF
ELECTRICAL
A850
2 SF
ELECTRIC
A847
23 SF
STAIR
196 SF
OFFICE
B805
138 SF
HAC
B806
32 SF
RESTROOM
C806
58 SF
RESTROOM
C807
58 SF
CONFERENCE/MEDIATION
C811
259 SF
STAIR
174 SF
STAIR
170 SF
MEN'S RESTROOM
A830
170 SF
WOMEN'S RESTROOM
A830A
140 SF
FELLOWS ROOM
A832
178 SF
ACOS
A837
110 SF
OFFICE
B804
119 SF
STAIR
174 SF
COMMUNICATIONS
A843A
42 SF
SERVICE ELEVATORS
A840
176 SF
FLOAT
A844
157 SF
UTILIZ. MGMT.
A841
355 SF
EXAM
A836
169 SF
OFFICE
B827
109 SF
OFFICE
B825
108 SF
OFFICE
B824
111 SF
CHIEF
B822a
130 SF
SHARED OFFICE
B821
184 SF
COMMUNICATIONS
B812
62 SF
BLUE TEAM
B808
346 SF
LARGE CONF.
B810
418 SF
SHARED OFFICE
B814
215 SF
TEAM ROOM
B815
320 SF
EEO PROGRAM MANAGER
C810
103 SF
OFFICE
C809
76 SF
FLOAT
A843
139 SF
SWING OFFICE
A842
150 SF
OFFICE
B826
115 SF
SECRETARY
B822
120 SF
OFFICE
B803
124 SF
OFFICE
B802
138 SF
OFFICE
B801
149 SF
OFFICE
B820
104 SF
COPY
B807
67 SF
PIMS
A838
151 SF
CACS & INFROMATICS
A839
540 SF
COPY/BREAK
A840a
201 SF
OFFICE
B828
103 SF
CORRIDOR
645 SF
CARE CORD.
B818
373 SF
KITCHENETTE
B816
96 SF
SWING OFFICE
A848
151 SF
Q. MGMT.
A846
921 SF
PASSAGE
A846F
697 SF
TEAM ROOM
A846A
144 SF
CORRIDOR
1032 SF
CORRIDOR
B820
168 SF
EXISTING COMM
ROOM SERVING
AREA A
EXISTING COMM
ROOM SERVING
AREAS B AND C
STAFF WAP (TYP)
PASSAGE
A846D
94 SF
PASSAGE
A846C
124 SF
PASSAGE
B823
48 SF
PASSAGE
A846B
133 SF
ALTD-10
ALTD-9
WALL MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.
FLOOR MOUNTED VOICE/DATA OUTLET. (2) CAT 6A (1) CAT 5e.
CEILING MOUNTED WIRELESS ACCESS POINT (GFGI). (1) CAT 6A
(CFCI).
W
PUBLIC ADDRESS SPEAKERS
TELECOMMUNICATIONS LEGEND
WALL MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
FLOOR MOUNTED VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
FURNITURE TYPE VOICE/DATA OUTLET. (1) CAT 6A (1) CAT 5e.
F
ALTD-7
GENERAL NOTE
1. CONTRACTOR SHALL SPACE INSTALL PA SPEAKERS
EVERY 20'. TERMINATE SPEAKERS TO EXISTING PA
SYSTEM.
2. WIRELESS ACCESS POINTS SHOWN ARE GFGI.
CONTRACTOR TO INSTALL CABLING BACK TO CLOSEST
IDF AND GOVERNMENT FURNISHED TILE ENCLOSURE AT
EACH WIRELESS ACCESS POINT LOCATION.
3. CONTRACTOR TO USE EXISTING CABLE SUPPORTING
INFRASTRUCTURE (AS MUCH AS POSSIBLE) TO
SUPPORT NEW CABLE. IF EXISTING PATHWAYS CANNOT
SUPPORT NEW CABLING PROVIDE 12'' X6'' WIRE MESH
CABLE TRAY FOR MAIN HORIZONTAL PATHWAY RUNS.
USE 2'' J-HOOKS FROM CABLE TRAY TO OUTLET.
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
A
B
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
OCT 27, 2017
SCALE: As indicated
TC108
506-330
ANN ARBOR VAMC
DS MK
TELECOMMUNICATIONS
AND SPECIAL SYSTEMS - 8TH
FLOOR
EXPAND 8TH FLOOR
MENTAL HEALTH
3/32" = 1'-0"
NEW TELECOMMUNICATIONS AND
SPECIAL SYSTEMS FLOOR PLAN - 8TH
197REVISIONS DATE
4-PR UTP CAT 6A PLENUM CABLE TO
VOICE/DATA OUTLETS AND STAFF WAP
OUTLETS
CAT 6A CABLES TO
GUEST WAP OUTLETS
EXISTING MULTIPAIR
CAT 3 CABLE
4-PR UTP CAT 5e
PLENUM BLUE CABLE
TO VOICE OUTLETS
78 INCHES AFF
KEY NOTE #
1 EXISTING EQUIPMENT RACK
GENERAL NOTE
1. INSTALLATION CONTRACTOR IS RESPONSIBLE FOR ALL SEISMIC
LOAD CALCULATIONS FOR CABLE TRAYS, CONDUITS AND OTHER
PATHWAYS IN THE CEILING IN ACCORDANCE WITH DIVISION 27
SEPECIFICATIONS.
2. ALL SLEEVES HAVE BUSHINGS & ARE FIRESTOPPED WITH PUTTY
AFTER INSTALLATION.
3. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING
TELECOM EQUIPMENT AND PLACEMENT OF NEW TELECOM
EQUIPMENT IN EACH COMM ROOM.
4. CAT 6A COLORS ARE AS FOLLOWS: BLUE (DATA AND CAT 5e
VOICE CABLES), YELLOW (WAP IN STAFF AREAS), PINK (WAP IN
GUEST AREAS).
2 48-PORT CAT 6A PATCH PANEL (CFCI), QTY AS REQUIRED.
3 110 TELEPHONE BLOCK (CFCI)
4 EXISTING 110 TELEPHONE BLOCK
5 EXISTING TELECOM EQUIPMENT
6 2 RMU HORIZONTAL MANAGER (CFCI)
SAFETY WIRE TO STRUCTURE
SPEAKER ENCLOSURE W/
INTEGRAL MTD. CLAMPS
CEILING TILE OR GWB
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: As indicated
TC401
506-330
ANN ARBOR VAMC
DS MK
TELECOMMUNICATIONS
ROOM DETAILS
EXPAND 8TH FLOOR
MENTAL HEALTH
N.T.S.
RACK ELEVATION-TYPICAL
N.T.S.
TELEPHONE BLOCK WALL
ELEVATION-TYPICAL
N.T.S.
CEILING MOUNTED VOICE SPEAKER
198REVISIONS DATE
XX-XXX
XX-XXX
x;1 x;24 x;1 x;2
XX-UNXXX
1 2
XX - UN XXX - S 03
TR NAME
UN-CLASSIFIED CABLE
WORK AREA ID
JACK ID IE, 01, 02, 03 ETC.
JACK TYPE: V-VOICE D-DATA S-SPARE T-TELEVISION
TYPICAL COMM ROOM
CLIENT SWITCH (PROVIDED BY VA)
48 PORT CAT 6A PATCH PANEL
4 PAIR UTP
CAT6A CABLE
4 PAIR UTP CAT6A PATCH CORD
WORK AREA ID
WORK AREA ID
TYPICAL 4 PORT WALL FACE PLATE
JACK ID IE, 01, 02, 03 ETC.
JACK TYPE: V-VOICE
D-DATA
S-SPARE
TR NAME
IE, IA, IB, ETC.
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: N.T.S.
TC402
506-330
ANN ARBOR VAMC
DS MK
TELECOM WIRING DETAIL -
DATA
EXPAND 8TH FLOOR
MENTAL HEALTH
N.T.S.
TELECOM WIRING DETAIL - DATA
199REVISIONS DATE
W B L
B L W
O R W
W O R
W G R
W B R
G R W
B R W x;1 x;25
W G R x;1
B L W
W B L
O R W
W O R
W B R
G R W
B R W
S L W
W S L
B L R
R B L
V L V I
B K B R
S L R
R O R
R G R
O R R
G R R
B R R
R B R
R S L
B K B L
B L B K
B K O R
B K G R
O R B K
G R B K
B R B K
B K S L
Y B L
S L B K
B L Y
Y O R
O R Y
G R Y
Y B R
Y G R
B R Y
S L Y
Y S L
V I- V L
V I- S L
V I- O R
O R V I
V I- G R
V I- B R
G R V I
B R V I x;25
S L V I
110 CONNECTOR BLOCK 110 CONNECTOR BLOCK
XX-UNXXX
TYPICAL COMM ROOM
INTERMEDIATE CROSS CONNECT (TYPICAL OF 25 PAIRS)
EXISTING MULTIPAIR UTP
CAT 3 PLENUM CABLE
4 PAIR UTP CAT 5e CABLE
HORIZONTAL CABLE IDENTIFICATION
TYPICAL 4 PORT WALL FACE PLATE
JACK ID
IE, 01, 02, 03 ETC.
JACK TYPE: V-VOICE D-DATA
S-SPARE T-TELEVISION
TR NAME
IE, IA, IB, ETC.
UN-CLASSIFIED WA
WORK AREA ID
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: N.T.S.
TC403
506-330
ANN ARBOR VAMC
DS MK
TELECOM WIRING DETAIL -
VOICE
EXPAND 8TH FLOOR
MENTAL HEALTH
N.T.S.
TELECOM WIRING DETAIL - VOICE
200REVISIONS DATE
NCP
N D
DATA BUS
CONNECTION TO
EXISTING
SECURITY PANEL
CAT 6 (TYP)
NETWORK SWITCH (BY OTHERS)
COMM CLOSET (TYP) TYPICAL FLOOR
SCP
KP MS CR PB
NS
IDS
IC
MS
CAT 6
IC
DS
INDOOR/OUTDOOR CAT 6
ADMIN OFFICE ROOM BB71SECURITY GATE
TO
TELEPHONE
SYSTEM
COMM CLOSET (TYP) TYPICAL FLOOR
AMP SS S S
AMP SS S S
M M M M
EXISTING
VOLUME CONTROLLER
AT INFORMATION DESK
CONTACT CLOSURE
INTERFACE
COMM CLOSET
(TYP) TYPICAL FLOOR
CAT 6A AND CAT5e (TYP.)
D A T A W W
P
COMM CLOSET (TYP) TYPICAL FLOOR
DATA BUS
CONNECTION
TO EXISTING
HOSPITAL
NURSE CALL
SYSTEM
EXISTING
NURSE CALL
PANEL
CAT6
NURSE CALL DOME LIGHT
NURSE CALL PULL CORD STATION
GENERAL NOTE
1. ALL WIRING SHALL BE PER MANUFACTURER'S RECOMMENDATIONS. RISER
DIAGRAM IS SCHEMATIC FOR EXACT QUANTITY OF DEVICES SEE FLOOR
PLANS. ELECTRICAL CONTRACTOR TO COORDINATE WITH PAGING VENDOR
FOR ALL MISCELLANEOUS PAGING DEVICES, INCLUDING WIRING AND
RACEWAY. REFER TO SPECIFICATIONS.
2. PAGING VENDOR SHALL SUPPLY ANY ADDITIONAL POWER SUPPLIES,
EMERGENCY BACKUP BATTERIES OR ANY HARDWARE NEEDED TO PROVIDE
A COMPLETE PAGING SYSTEM.
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: As indicated
TC601
506-330
ANN ARBOR VAMC
DS MK
SPECIAL SYSTEMS RISER
DIAGRAMS
EXPAND 8TH FLOOR
MENTAL HEALTH
N.T.S.
SECURITY SYSTEM
N.T.S.
PAGING SYSTEM AND MUSIC SYSTEM
N.T.S.
TELECOM SYSTEM
N.T.S.
NURSE CALL SYSTEM
201REVISIONS DATE
P PP P P P
P
P
P P
P P
P P
P P
P P
P P
P
P
P PP P P P P P P P P P
P P
PP P
P P
P P
P P
P
PP PPPP
P P
P P
P P
P P
P
P
P P
P P
P P
P PP P P P P P P P P P
P P
P
P PP P P P
P P
P P
P
P PP P P P
P PP P P
P P
P
P PP P P
P P
P P
P P
PP PPP
P P
P P
P P
P PP P P P P P
P
P PP P
P P
P
PP PP
P P
P
S S
S S
S S
S S
S S
S S
S
S SS
S
S S S S S S S S S S S S S S S S
P PP P
P
P
P P
P
P P
P P
F
F
F
K P
C R
C R
C R
MS
M S
KP
CR
F
CR
F
C R
C R
F
DR
CORRIDOR
BB98
131 SF
COMM.2
BB77B
11 SF
COMM.1
BB77A
13 SF
INTERVIEW
BB91
55 SF
OFFICE PHYS SEC
BB80
104 SF
TRAINING/BREAK
BB93
309 SF
STAFF GYM
BB70
369 SF
STORAGE
BB78
141 SF
WOMEN'S SHOWER
BB95A
81 SF
WOMEN'S LOCKER
BB95
66 SF
ALCOVE
BB71A
33 SF
ADMIN
BB71
169 SF
TOILET
BB73
68 SF
HOLDING
BB92
54 SF
EVIDENCE
BB90
49 SF
STORAGE
BB93A
70 SF
ARMS OFFICE
BB72
143 SF
CORR.
BB97
257 SF
OFFICE TRAINING
BB85
160 SF
OFFICE DEPUTY
BB83
110 SF
OFFICE CHIEF
BB82
124 SF
OFFICE INVSTGTR
BB81
108 SF
BIOMED OFFICE
BB32
246 SF
OPEN OFFICE
BB96
394 SF
TOILET
BB75
66 SF
OFFICE EM. MGR.
BB76
130 SF
OFFICE
BB77
109 SF
ALCOVE
BB74A
56 SF
MEN'S LOCKER
BB94
175 SF
MEN'S SHOWER
BB94A
219 SF
CORR.
BB98B
67 SF
EXISTING COMM ROOM
BB26. LOCATION OF
EXISTING SECURITY
DISTRIBUTION EQUIPMENT
ALTD-2
IC
MS
KEY NOTE #
1 CAMERA SHALL INCLUDE BUILT IN AUDIO. COORDINATE
CAMERA PALCEMENT TO ENSURE VIEW OF POLICE SUBJECT.
GENERAL NOTE
1. CONTRACTOR TO USE EXISTING SECURITY CABLE SUPPORTING
INFRASTRUCTURE AS MUCH AS POSSIBLE. PROVIDE NEW AS
NEEDED.
2. NEW CAMERAS SHOWN SHALL TERMINATE TO NEW IP VIDEO
MANAGEMENT SYSTEM UNDER SEPARATE PROJECT.
CONTRACTOR TO COORDINATE WITH VA SECURITY FOR
TERMINATION LOCATION.
3. UNLESS OTHERWISE NOTED, SECURITY DEVICES SHOWN SHALL
TERMINATE TO EXISTING SECURITY PANELS INSIDE COMM ROOM
BB26. PROVIDE ADDITIONAL SECURITY DISTRIBUTION
EQUIPMENT AS NEEDED. COORDINATE WITH VA POLICE FOR
EXACT TERMINATION LOCATIONS.
2 EXISTING VIDEO SURVEILLANCE EQUIPMENT TO REMAIN.
CONTRACTOR TO PROTECT EQUIPMENT DURING RENOVATION.
3 EXISTING SECURITY ALARM EQUIPMENT OT REMAIN.
CONTRACTOR TO PROTECT EQUIPMENT DRUING RENOVATION.
EQUIPMENT LEGEND
CR WALL MOUNTED CARD READER
CEILING MOUNTED GLASS BREAK SENSORGB
SECURITY PANIC BUTTONPB
CEILING MOUNTED FIXED IP CAMERAF
CEILING MOUNTED SECURITY MOTION SENSORMS
INTRUSION DETECTION SYSTEM KEYPADKP
CEILING MOUNTED 180 DEGREE FIXED IP CAMERAF
DOOR RELEASE BUTTONDR
INTERCOM MASTER STATION (AIPHONE IX-MV OR EQUAL)IC
MS
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: As indicated
TY100
506-330
ANN ARBOR VAMC
DS MK
SECURITY FLOOR PLAN -
BASEMENT
EXPAND 8TH FLOOR
MENTAL HEALTH
3/32" = 1'-0"
NEW SECURITY FLOOR PLAN -
BASEMENT
202REVISIONS DATE
M an it ow oc
M an it ow oc
P PP
P
P P
P
P
P
P P
S S
S
S S
S S
S S
S
S
S S
S
S SS S S
S
S S
S
S SS S S S S S
S
S S
S
S S S
S SS
S S
PP PPPP
P P
P P
P
P P
P P
P
P P
P P
P
CR
GB
GB
GB
GB
GB
PB
P B
F
F
F
F
F
CORRIDOR
B204
410 SF
COFFEE SHOP
B203
292 SF
LOBBY
B200
689 SF
WHEELCHAIR ALCOVE
B205
39 SF
WAITING
B202
78 SF
VESTIBULE
B201
108 SF
EXISTING COMM ROOM
SERVING AREA B
GENERAL NOTE
1. CONTRACTOR TO USE EXISTING SECURITY CABLE SUPPORTING
INFRASTRUCTURE AS MUCH AS POSSIBLE. PROVIDE NEW AS
NEEDED.
2. NEW CAMERAS SHOWN SHALL TERMINATE TO NEW IP VIDEO
MANAGEMENT SYSTEM UNDER SEPARATE PROJECT.
CONTRACTOR TO COORDINATE WITH VA SECURITY FOR
TERMINATION LOCATION.
3. UNLESS OTHERWISE NOTED, SECURITY DEVICES SHOWN SHALL
TERMINATE TO A NEW SECURITY PANELS (CFCI) INSIDE EXISTING
COMM ROOM B143. SECURITY PANELS MUST BE COMPATIBLE
WITH EXISTING HOSPITAL ACCESS CONTROL AND INTRUSION
DETECTION SYSTEMS.
EQUIPMENT LEGEND
CR WALL MOUNTED CARD READER
CEILING MOUNTED GLASS BREAK SENSORGB
SECURITY PANIC BUTTONPB
CEILING MOUNTED FIXED IP CAMERAF
CEILING MOUNTED SECURITY MOTION SENSORMS
CEILING MOUNTED FIXED IP CAMERAF
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: As indicated
TY101
506-330
ANN ARBOR VAMC
DS MK
SECURITY FLOOR PLAN - 1ST
FLOOR
EXPAND 8TH FLOOR
MENTAL HEALTH
3/32" = 1'-0"
NEW SECURITY FLOOR PLAN - 1ST
203REVISIONS DATE
TO CONTROL PANEL
1'' CONDUIT
JUNCTION BOX (SECURED SIDE)
PROVIDE TAMPER SWITCH
3/4'' CONDUIT
FINISHED CEILING
6''RECESSED DOOR
CONTACT
ELECTRIC POWER TRANSFER
(PROVIDED BY DIV. 8)
12'' MAX
ELECTRIFIED MORTISE LOCKSET
WITH INTEGRATED MICRO-SWITCH
REX (PROVIDED BY DIV. 8)
CARD READER (UNSECURED SIDE)
CL
SECURE SIDE
UNSECURE SIDE
FINISHED CEILING
CL
SECURE SIDE
UNSECURE SIDE
12'' MAX
6''
TO CONTROL PANEL
1'' CONDUIT
RECESSED DOOR
CONTACTS
ELECTRIC POWER TRANSFER
(PROVIDED BY DIV. 8)
CARD READER
(UNSECURED SIDE)
ELECTRIFIED
MORTISE LOCKSET
WITH INTEGRATED
MICRO-SWITCH REX
(PROVIDED BY DIV. 8)
3/4'' CONDUIT
NOTES:
A. COORDINATE WITH DIV. 8 FOR
EXACT HARDWARE/CONDUIT
REQUIREMENTS.
B. ALIGN CONDUIT WITH MAGNETIC
CONTACT SWITCH LOCATION.
COORDINATE WITH DOOR & FRAME
SUPPLIER.
DOOR DETAIL NOTES:
1. JUNCTION BOXES AND PULL BOXES SHALL BE SIZED
ACCORDINGLY WITH COVER PLATE PAINTED BLUE UNLESS
OTHERWISE INDICATED. SECURE COVER PLATE WITH TAMPER
RESISTANT SCREWS.
2. CONDUIT FROM DOOR DEVICE TO JUNCTION BOX ABOVE DOOR
SHALL BE 3/4'' EMT UNLESS NOTED OTHERWISE.
3. POSITION JUNCTION BOX AS NOT TO INTERFERE WITH EXISTING
CONDUIT OF OTHER EXISTING SYSTEMS.
4. WHERE NO FINISHED CEILING EXIST, JUNCTION BOXES OVER
DOORS SHALL BE PLACED AT LEAST 9'' FROM BOTTOM OF BOX
TO TOP OF DOOR AS SPACE PERMITS.
5. DOOR TYPE DETAILS ARE SHOWN FOR EQUIPMENT LAYOUT AND
WIRING REQUIRED. MAY NEED TO BE REVISED TO FIT SPECIFIC
DOOR APPLICATIONS.
6. DUAL DOOR CONTACT ON DOOR SHALL BE WIRED AS SINGLE
ZONE WITH END OF LINE RESISTOR ONLY ON THE LAST DOOR
CONTACT.
7. WIRING FOR ACCESS CONTROL AND IDS SHALL BE ROUTED IN
WALLS WHERE POSSIBLE. CONDUIT SHALL BE INSTALLED ON
SECURE SIDE OF WALL WHERE APPLICABLE.
8. UNLESS OTHERWISE NOTED, FOR CMU WALLS, SURFACE MOUNT
EQUIPMENT AND CONDUIT. FOR HOLLOW WALLS, RUN CABLE IN
CONDUIT IN INTERIOR. FOR ARMORED CABLE, PROVIDE AS PART
OF DOOR CONTACT, PENETRATE WALL ABOVE DOOR CONTACT
WITH A SINGLE GANG BOX AND MATCHING SINGLE HOLE COVER
PLATE. RUN CABLE IN WALL TO ABOVE CEILING, THEN CONNECT
TO ABOVE DOOR JUNCTION BOX WITH SUPPLIED CONNECTORS.
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
1W
Oct 27, 2017
SCALE: As indicated
TY401
506-330
ANN ARBOR VAMC
DS MK
DEVICE/DOOR DETAILS EXPAND 8TH FLOOR
MENTAL HEALTH
N.T.S.
SINGLE ACS DOOR WITH ELECTRIFIED
LOCKSET
N.T.S.
DOUBLE ACS DOOR WITH ELECTRIFIED
LOCKSET
204REVISIONS DATE
REINFORCED CONCRETE SLAB
CONDUIT BACK TO
SECURITY EQUIPMENT
JUNCTION BOX
CEILING BRACKET
1/2'' 2''
IP DOME CAMERA
SUSPENDED CEILING
MOUNTING PLATE
8 27/32''
NOTES:
1. ARMORFLEX CONDUIT TO BE PROVIDED BY THE CONTRACTOR
2. ALL CAMERA ASSEMBLIES SHALL BE FIRMLY ATTACHED TO SUBSTANTIAL
WALL SURFACES OR STRUCTURAL MEMEBERS. CAMERA ASSEMBLY
INSTALLATION DIRECTLY TO DRYWALL SURFACES SHALL NOT BE
ACCEPTABLE.
CONDUIT BACK TO SECURITY EQUIPMENT
GYPSUM
WALL BOARD
4.52''
Ø 3.58''
CONDUIT BACK
TO SECURITY
EQUIPMENT
GYPSUM WALL
BOARD
4.52''
Ø 3.58''
NOTES:
1. ALL CAMERA ASSEMBLIES SHALL BE
FIRMLY ATTACHED TO SUBSTANTIAL WALL
SURFACES OR STRUCTURAL MEMBERS.
NOTES:
1. MOUNT CAMERA ASSEMBLY AT MOST
DESIRABLE HEIGHT ABOVE FINISHED
FLOOR TO AVOID OBSTRUCTIONS AND TO
PROVIDE THE FIELD-OF-VIEW DESIRED.
2. ALL CAMERA ASSEMBLIES SHALL BE
FIRMLY ATTACHED TO SUBSTANTIAL WALL
SURFACES OR STRUCTURAL MEMBERS.
N
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Dep…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.