36C25018B0817-005.pdf
PDF 13 MB Posted
- Attached to
- Expand 8th Floor - Mental Health 506-330
- Solicitation number
- 36C25018B0817
About this file
36C25018B0817 S02 - Drawings VOL1-Part 2 - 506-330.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25018B0817-0005000.docx | DOCX document | |
| 36C25018B0817-0005001.pdf | ||
| 36C25018B0817-0005003.pdf | ||
| 36C25018B0817-0005002.pdf | ||
| 36C25018B0817-0004000.docx | DOCX document | |
| 36C25018B0817-0003001.docx | DOCX document | |
| 36C25018B0817-0003000.docx | DOCX document | |
| 36C25018B0817-0002000.docx | DOCX document | |
| 36C25018B0817-0001000.docx | DOCX document | |
| 36C25018B0817-011.pdf | ||
| 36C25018B0817-003.pdf | ||
| 36C25018B0817-007.pdf | ||
| 36C25018B0817-008.pdf | ||
| 36C25018B0817-012.pdf | ||
| 36C25018B0817-001.docx | DOCX document | |
| 36C25018B0817-010.pdf | ||
| 36C25018B0817-013.docx | DOCX document | |
| 36C25018B0817-016.docx | DOCX document | |
| 36C25018B0817-009.pdf | ||
| 36C25018B0817-006.pdf | ||
| 36C25018B0817-014.pdf | ||
| 36C25018B0817-015.pdf | ||
| 36C25018B0817-002.pdf | ||
| 36C25018B0817-004.pdf | ||
| 36C25018B0817-000.docx | DOCX document |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
EXIST.
EXIST.
A850
ELECTRICAL A847
ELECTRIC
A843
SERVICE ELEV
A830
MEN'S RESTROOM
A830A
WOMEN'S
RESTROOM
A838
PIMS
B803
OFFICE
B804
OFFICE
A837
ACOS
A831A
FELLOWS ROOM
B824
OFFICE
B826
OFFICE
B825
OFFICE
B827
OFFICE
B828
OFFICE
B829
EXAM
A839
CACS &
INFOMATICS
A845
FLOAT
A846
Q. MGMT.
A842
SWING OFFICE
A844
FLOAT
A841
UTILIZ. MGMT.
B802
OFFICE
B801
OFFICE
B800
OFFICE
A848
SWING OFFICE
A843B
COPY/BREAK
CORRIDORA843A
COMMUNICATIONS
B805
HAC
A846A
TEAM ROOM
A
C O
M M
8' - 0"
STAIR1
STAIR
STAIR
8' - 0"
ALTD-7
AI530
J
J
K
K
IH''F''E''
L
L
13 13
12 12
11 11
10 10
9 9
5 5
6 6
G'F' POM
M
N QE' H'C' D' SR
4' 4'
7' 7'
8 8
J'
J'
3.9 3.9
K'
K'
CUR
CUR
TYP.
AI530
TYP.
AI530
TYP.
AI530
TYP.
AI530
TYP.
AI530
TYP.
AI530
TYP.
AI530
TYP.
REFLECTED CEILING PLAN LEGEND
AREAS TO BE SUSPENDED ACOUSTIC CEILING
AREAS OF EXISTING SUSPENDED ACOUSTIC TILE TO
BE REWORKED DUE TO NEW CONSTRUCTION.
AREAS TO BE FINISHED GYPSUM BOARD CEILING
FLUORESCENT LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
SUPPLY DIFFUSER - SEE MECHANICAL DRAWINGS
EXHAUST DIFFUSER - SEE MECHANICAL DRAWINGS
INDUSTRIAL LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
CEILING MOUNTED EXIT SIGN - SEE ELECTRICAL DRAWINGS
PENDANT LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
RECESSED LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
CEILING HEIGHT ABOVE FINISHED FLOOR
8'-0"
GENERAL NOTES - CEILING PLAN
1. ELECTRICAL AND MECHANICAL FIXTURES AND DUCTWORK ARE SHOWN FOR REFERENCE ONLY.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS.
2. REFER TO FINISH SCHEDULE FOR CEILING FINISHES.
RETURN AIR DIFFUSER - SEE MECHANICAL DRAWINGS
ALTERNATE DEDUCT LEGEND
ALTD-1: Provide solid resin tile flooring in lieu of terrazzo flooring. Terrazzo flooring in rooms CB184, CB184A, CB184C, and B184 to be 36” x 36” homogeneous solid resin resilient tile. Refer to specifications and sheets ID001, ID002, and ID101.
ALTD-2: Alternate to be 1 CAT 6A drop in lieu of 2 CAT 6A drops. Refer to
Telecommunications sheets, TC100, TC101, and TC108.
ALTD-3: All work pertaining to the renovations of rooms BB76, BB77, and BB77C in the
Basement. Sheets AD100, AE100, AE100B, AC120, ID001, ID002, ID100, FX200, FA100, FA200, MH100B, MP100B, ED100, EP100B, EL100B, TC100, TY100. Alternate: Existing to remain.
ALTD-4: Replacement of existing doors on 8th floor, Base Bid: Existing doors to be replaced, existing frames to remain. Refer to sheets AD108A, AD108B, AE108A, AE108B, and AI600. Alternate: Existing doors and frames to remain.
ALTD-5: All work associated with Corridor C8-2, C8-4, C8-5, C800, C801, C803, C803A and C804. Sheets AD108B, AE108B, AC128B, AI428, AW001, AW002, AW108, ID001, ID003, ID108B, FX108, FX208, FA108, FA208, PD108B, PL108B, MD108B, MH108B, MP108B, ED108B, EP108B, EL108B, and TC108. Alternate: Existing to remain.
ALTD-6: Light fixture alternate. Refer to Electrical Lighting Fixture Schedule, sheet E601.
ALTD-7: All work associated with Toilet Rooms A830 and A830A. Refer to sheets
AD108A, AE108A, AC128A, AI428, ID108A, FX108, FX208, FA108, FA208, PD108A, PL108A, MD108A, MH108A, MP108A, ED108A, EP108A, EL108A, and TC108. Alternate: Existing to remain, no new work.
ALTD-8: All work pertaining to rooms BB108 and BB118A. Remove rooms BB108 and
BB118A, floor slab, finishes, roof slab, roofing, roof drain, lighting, and power.
ALTD-9: All work pertaining to the removal/replacement of plaster, drywall and cavity insulation at exterior walls on the 8th floor renovations. Sheets AD108A, AD108B, AE108A, AE108B, and AE324. Alternate: Existing exterior wall(interior finish) to remain.
ALTD-10: All work pertaining to the removal and replacement of the existing exterior windows and window sills within the 8th floor renovations. Sheets AD108A, AD108B, AE108A, AE108B, and AI600. Alternate: Existing windows and sills to remain.
ALTD-11: All work pertaining to the furnishing and installation of the sunshade on the west elevation of the new addition. Sheets SS102A, SS503, AE200, AE300, and AE323.
Alternate: No sunshade.
NORTH
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN -
8TH FLOOR UNIT A
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o n e o e q u a rt e r in c h o th re e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AC128A
506-330
ANN ARBOR VAMC
OCT. 27, 2017
1W
JRB JK
REFLECTED CEILING PLAN -
8TH FLOOR UNIT A
EXPAND 8TH FLOOR
MENTAL HEALTH
U N
IT
B
U N
IT
A
U N
IT
B
U N
IT
A
205REVISIONS DATE
KEY PLAN
8' - 0" 8' -
0"
8' - 0"
8' - 0"
8' - 10"
8' - 6"
8' - 10"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0" 8' -
0"
B804
OFFICE
B812
COMMUNICATIONS
C800
RESTROOM
C801
RESTROOM
C804
CONFERENCE/MEDIATION
B818
CARE CORD.
B815
TEAM ROOM
B814
SHARED OFFICE
B810
LARGE CONF.
B807
BLUE TEAM
B806
COPY
B820
OFFICE
B821
SHARED OFFICE
B822
SECRETARY
B824
OFFICE
B825
OFFICE
C803
OFFICE
C803A
EEO PROGRAM
MANAGER
B822a
CHIEF
C8-2
CORRIDOR
B816
KITCHENETTE
B805
HAC
STAIR
STAIR
B813
ELECTRICAL
7' - 6"
ALTD-5
AI530
AI530
AI530
SIM
J
J
K
K
17 17
H''F''
16 16
15 15
L
L
B C D E F G H
M
M
J'
J'
K'
K'
1.9
B.3
1.7
4.1
AI530
TYP.
AI530
TYP.
AI530
TYP.
AI530
TYP.
AI530
TYP.
REFLECTED CEILING PLAN LEGEND
AREAS TO BE SUSPENDED ACOUSTIC CEILING
AREAS OF EXISTING SUSPENDED ACOUSTIC TILE TO
BE REWORKED DUE TO NEW CONSTRUCTION.
AREAS TO BE FINISHED GYPSUM BOARD CEILING
FLUORESCENT LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
SUPPLY DIFFUSER - SEE MECHANICAL DRAWINGS
EXHAUST DIFFUSER - SEE MECHANICAL DRAWINGS
INDUSTRIAL LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
CEILING MOUNTED EXIT SIGN - SEE ELECTRICAL DRAWINGS
PENDANT LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
RECESSED LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
CEILING HEIGHT ABOVE FINISHED FLOOR
8'-0"
GENERAL NOTES - CEILING PLAN
1. ELECTRICAL AND MECHANICAL FIXTURES AND DUCTWORK ARE SHOWN FOR REFERENCE ONLY.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS.
2. REFER TO FINISH SCHEDULE FOR CEILING FINISHES.
RETURN AIR DIFFUSER - SEE MECHANICAL DRAWINGS
ALTERNATE DEDUCT LEGEND
ALTD-1: Provide solid resin tile flooring in lieu of terrazzo flooring. Terrazzo flooring in rooms CB184, CB184A, CB184C, and B184 to be 36” x 36” homogeneous solid resin resilient tile. Refer to specifications and sheets ID001, ID002, and ID101.
ALTD-2: Alternate to be 1 CAT 6A drop in lieu of 2 CAT 6A drops. Refer to
Telecommunications sheets, TC100, TC101, and TC108.
ALTD-3: All work pertaining to the renovations of rooms BB76, BB77, and BB77C in the
Basement. Sheets AD100, AE100, AE100B, AC120, ID001, ID002, ID100, FX200, FA100, FA200, MH100B, MP100B, ED100, EP100B, EL100B, TC100, TY100. Alternate: Existing to remain.
ALTD-4: Replacement of existing doors on 8th floor, Base Bid: Existing doors to be replaced, existing frames to remain. Refer to sheets AD108A, AD108B, AE108A, AE108B, and AI600. Alternate: Existing doors and frames to remain.
ALTD-5: All work associated with Corridor C8-2, C8-4, C8-5, C800, C801, C803, C803A and C804. Sheets AD108B, AE108B, AC128B, AI428, AW001, AW002, AW108, ID001, ID003, ID108B, FX108, FX208, FA108, FA208, PD108B, PL108B, MD108B, MH108B, MP108B, ED108B, EP108B, EL108B, and TC108. Alternate: Existing to remain.
ALTD-6: Light fixture alternate. Refer to Electrical Lighting Fixture Schedule, sheet E601.
ALTD-7: All work associated with Toilet Rooms A830 and A830A. Refer to sheets
AD108A, AE108A, AC128A, AI428, ID108A, FX108, FX208, FA108, FA208, PD108A, PL108A, MD108A, MH108A, MP108A, ED108A, EP108A, EL108A, and TC108. Alternate: Existing to remain, no new work.
ALTD-8: All work pertaining to rooms BB108 and BB118A. Remove rooms BB108 and
BB118A, floor slab, finishes, roof slab, roofing, roof drain, lighting, and power.
ALTD-9: All work pertaining to the removal/replacement of plaster, drywall and cavity insulation at exterior walls on the 8th floor renovations. Sheets AD108A, AD108B, AE108A, AE108B, and AE324. Alternate: Existing exterior wall(interior finish) to remain.
ALTD-10: All work pertaining to the removal and replacement of the existing exterior windows and window sills within the 8th floor renovations. Sheets AD108A, AD108B, AE108A, AE108B, and AI600. Alternate: Existing windows and sills to remain.
ALTD-11: All work pertaining to the furnishing and installation of the sunshade on the west elevation of the new addition. Sheets SS102A, SS503, AE200, AE300, and AE323.
Alternate: No sunshade.
NORTH
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN -
8TH FLOOR UNIT B
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AC128B
506-330
ANN ARBOR VAMC
OCT. 27, 2017
1W
JRB JK
REFLECTED CEILING PLAN -
8TH FLOOR UNIT B
EXPAND 8TH FLOOR
MENTAL HEALTH
U N
IT
B
U N
IT
A
U N
IT
B
U N
IT
A
BUILDING 22
AE300
AE300
AE301
AE301
AE301
J
J
K
K
I
22'
H''F''E''
L
G'F'E' H'
K'
K'
AE301
AE301
AE301
B.3
AE140
RDOD
RDOD
SL
O
P E
/4
'-0
SL
O
P E
/4
'-0
SL
O
P E
/4
'-0
SL
O
P E
/4
'-0
OD
RD
UNIT
'A'
UNIT
'B'
UNIT
'A'
UNIT
'B'
1.7
RD
ROOFTOP VENTILATOR;
REFER TO MECHANICAL
DRAWINGS
ROOFTOP CONDENSING UNIT;
REFER TO MECHANICAL
ROOFTOP UNIT; REFER TO
MECHANICAL DRAWINGS
EXHAUST AIR; REFER TO
MECHANICAL DRAWINGS
ROOF ACCESS LADDER, HIGH
ROOF TO LOW ROOF
ROOF ACCESS LADDER
TO HIGH ROOF W/
SECURITY ACCESS AT
GRADE
SLIP-RESISTANT WALKWAY
PAD/ROLL PER MFTR'S
STANDARDS, TYP.
ALTD-8
RD
SL
O
P E
/4
'-0
1.91.9
4.1
4.1
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
EXTEND AND PATCH EXISTING
CORRIDOR CONNECTOR ROOF
W/ MATCHING EXISTING ADJ.
CONSTRUCTION, REFER TO
STRUCTURAL & DETAILS
ROOF PLAN LEGEND
NEW ROOF DRAIN
OVERFLOW DRAIN
EXISTING EXHAUST FAN (E.F.) OR RELIEF VENT (R.V.) IN ROOF AREA
INDICATES ROOF PITCH
RUBBER ROOF WALKWAY TRAFFIC PAD- ADHERE PAD TO ROOF MEMBRANE
TYPICAL ROOF IS (FULLY ADHERED) SINGLE-PLY MEMBRANE ROOFING ON RIGID
INSULATION ON METAL DECK.
GENERAL NOTES - ROOF PLAN
1. SEE MECHANICAL DRAWINGS FOR LOCATIONS OF PLUMBING VENTS, FLASH AS SPECIFIED.
2. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS.
3. TYPICAL ROOF IS (FULLY ADHERED) SINGLE-PLY MEMBRANE ROOFING ON RIGID INSULATION
ON METAL DECK OR CONCRETE DECK. (PROVIDE TAPERED INSULATION TO CREATE SLOPES TO
DRAINS)
4. TAPERED INSULATION LAYOUTS ARE SCHEMATIC ONLY. FINAL LAYOUT FOR THE PROPOSED
AREA SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
5. MINIMUM 1/4" PER FOOT SLOPE AT ALL NEW LOW SLOPE ROOF AREAS.
6. MINIMUM 1/8" PER FOOT SLOPE AT ALL EXISTING RE-ROOF LOW SLOPE ROOF AREAS.
7. REFER TO PLUMBING SHEETS FOR ROOF DRAIN DETAILS AND INFORMATION.
R.D.
O.D
E.F.
TAPERED INSULATION
18 18
G'
AE301
B.3
RD
SL
O
P E
1.7
1.91.9
C
C
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AE140
506-330
ANN ARBOR VAMC
OCT. 27, 2017 JRB JLK
ROOF PLAN EXPAND 8TH FLOOR
MENTAL HEALTH
NORTH
SCALE: 1/8" = 1'-0"
ROOF PLAN
1W
SCALE: 1/4" = 1'-0"AE140
ROOF PLAN - CANOPY ROOF01
1W
GALVANIZED
B-LINE
CLAMP (B-
3252)
PIPING
(TYPICAL)
UNISTRUT
NUT
4x4
REDWOOD
RAIL
FELT
PAD
ROOFIN
G
GALVANIZED
UNISTRUT (P-
1000) LENGTH
AS REQ'D.
GALVANIZED
OR BRASS
SCREWS
INSTALLATION NOTES:
1. LEAVE PIPE CLAMPS SLIGHTLY LOOSE TO
ALLOW FOR EXPANSION
2. SEE SPECIFICATIONS FOR PIPE SUPPORT
SPACING.
3. ALL FASTENERS TO BE BRASS, GALVANIZED
OR STAINLESS STEEL.
WROUGHT
STRAP GRINNEL
# 262 W/ 3/8"
LAG SCREWS.
MEMBRANE
UNDERLAYMENT.
PIPE
4"x4"x2'-0"
PRESSURE TREATED
WOOD PIPE
SUPPORT, 10'-0"
MAXIMUM ON
CENTER.
PAINT ALL GAS PIPES
EXPOSED ON ROOF AND
OUTSIDE WALLS. COLOR
PER ARCHITECT.
NOTE:
ABOVE APPLIES TO ALL ROOF-MOUNTED NATURAL GAS PIPE SMALLER
THAN 3" DIAMETER. ALL ROOF-MOUNTED 3" AND 4" DIAMETER PIPE SHALL
BE SUPPORTED WITH PIPE STANDS, MIRO INDUSTRIES MODEL 3-RAH FOR 3"
DIA. PIPE AND MODEL 4-RAH FOR 4" DIA. PIPE. EACH WITH
POLYCARBONATE RESIN BASE, 10'-0" MAXIMUM O.C. PROVIDE AND
INSTALL A SHEET OF ROOF MEMBRANE UNDERLAYMENT UNDER EACH
STAND.
STRAINER BASKET
RUBBERGUARD
EPDM MEMBRANE
BONDING ADHESIVE
(ADHERED SYSTEMS ONLY)
WATER DAM COMPRESSION RING
INSULATION
INSULATION
(SEE NOTES)
SUBSTRATE SUBSTRATE
OVERFLOW ROOF
DRAIN
24" (610 mm) MIN.
NOTES
1. INSULATION ADJACENT TO DRAIN TO BE APPROPRIATE
INSULATION WITH APPROPRIATE BONDING SURFACE.
2. WATER BLOCK MIN. OF 1/2 OF 10 OZ (295 mL) TUBE PER 4"
DRAIN. USE DDITIONAL WATERBLOCK FOR LARGER
DRAINS.
12" (305 mm) 1/2" (13 mm)
SUMP AREA FIELD SEAM REQUIREMENTS:
A. IF SEAM EDGE IS WITHIN 9" OF DRAIN
COMPRESSION RING, EPDM TARGET PATCH REQUIRED.
B. IF FIELD EDGE IS WITHIN 9" (229 mm) TO 18" (457
mm) OF DRAIN COMPRESSION RING, INSTALL A LAYER OF
5" QUICKSEAM FLASHING CENTERED OVER SEAM EDGE.
5" QUICK SEAM FLASHING SHALL EXTEND 3" MIN.
BEYOND EDGE OF SUMP.
MEMBRANE SLOPE LIMITS:
A. MAXIMUM SLOPE FOR MAX
MEMBRANE SHALL BE 2" IN - 12".
B. MAXIMUM SLOPE FOR STANDARD
MEMBRANE SHALL BE 1/2" IN - 12".
STRAINER
BASKET
COMPRESSION
RING
PRIMARY
ROOF DRAIN
LEAF GRAT E
USE WITH 3 0R 4 INCH
DRAINS ONLY
3. IN REROOF APPLICATIONS:
-REMOMVE EXISTING FLASHING DOWN TO THE METAL BOWL.
-REPAIR OR REPLACE BROKEN DRAIN COMPONENTS.
-DRILL AND TAP BROKEN DRAINS , BOLTS, AND
REPLACE IF NECESSARY.
SEE MECHANICAL PLANS FOR FLUE LOCATIONS
PROVIDE A ONE (1) INCH AIR SPACE REQUIRED BETWEEN HEAT PIPE AND
COLLAR
NOTE:
SEALANT
CANOPY
1 1/2"
CONTINUOUS
FIELD HEAT WELD
TYP. HEAT PIPE BY
MECH. CONTR.
MEMBRANE ROOFING
SYSTEM ON 4" RIGID
INSULATION ON METAL
DECK
STRIP MASTIC OR SEALANT
STAINLESS STEEL ADJ. BAND
PREFABRICATED VENT STACK
FLASHING
METAL COLLAR
STEEL JOIST
M
IN
1" MIN.
DECK
IN
SULA
TIO
N
MEMBRANE
OPENIN
G
IN
D
ECK
Note 1: TWO SCREWS THROUGH CAPS ARE TO BE ON OPPOSING SIDES.
PREDRILL HOLES THROUGH SIDES OF CAP, TWO INCHES ABOVE
BOTTOM OF CAP.
VENT CAP
4-INCH
SCREW
(TWO TOTAL)
SEE NOTE 1
6-INCH
FACTORY
WELDED SKIRT
RAISED MARK
SEE NOTE 1
1 1/2-INCH
FIELD
WELD
VENT
SCREEN
VENT BASE
APPROVED DL
SEALANT BETWEEN
MEMBRANE
& INSULATIONMIN. FOUR
FASTENERS THROUGH
DECK
2"
Note 2: OPENING IN DECK MUST NOT EXCEED VENT SIZE
Note 3: ONLY TO BE USED FOR PASSIVE VENTING OF ATTIC SPACE.
NOTE:
PERIMETER FASTENING OF THE DECK MEMBRANE WILL BE THE
SAME FASTENING PATTERN AS THE FIELD MEMBRANE, MAX.
18-INCHES ON CENTER, AND NO LESS THAN ONE FASTENER
PER SIDE.
DECK
GALVANIXED
NAILS 6-INCHES
ON DIAMETER
RECTANGULAR PENETRATION
Duro-Last
PREFEBRICATED
CUSTOM CURB
FLASHING
DECK
M
IN
Note 1: IF A LEAD FLASHING IS PRESENT ON THE PIPE , IT MUST BE
REMOVED BEFORE A DURO-LAST STACK FLASHING IS INSTALLED.
Note 2: MEMBRANE ATTACHMENT AROUND THE PENETRATION WILL BE THE SAME AS THE
DECK MEMBRANE, MAX. 18-INCHES ON CENTER, AND A MINIMUM OF ONE
PLATE/FASTENER PER FLASHING.
DECK
TYPICAL VENT PIPE
DURO-LAST
PREFABRICATED VENT
STACK FLASHING
DURO-LAST CAULK
STAINLESS STEEL BAND
POSITIONED 1/4-INCH
FROM THE TOP OF THE
STACK FGLASHING
M
IN
Note 1: ALL COPING CAP JOINTS MUST UTILIZE A 6-INCH CONCEALED SPLICE PLATE.
Note 2: ALL JOINTS ARE TO BE SEALED WITH AN APPROVED DURO-LAST SEALANT ON
TOP OF THE SPLICE PLATE, ON BOTH SIDES OF THE JOINT. ALLOW A 1/4-INCH
GAP BETWEEN COPING SECTIONS.
Note 3: ON THE INSIDE EDGE OF THE COPING CAP BASE CLEAT, LEAVE A 3/8-INCH
GAP BETWEEN THE CLEAT AND THE WALL TO ALLOW THE COPING CAP TO
SNAP INTO PLACE.
Note 4: ALL FASTENERS MUST PENETRATE INTO THE WOOD NAILER A MINIMUM OF 1 1/2-INCHES.
16 GUAGE METAL CLEAT
(16-INCH LENGTHS)
6-INCH CONCEALED SPLICE PLATE
FORMED METAL COPING CAP
(10-FOOT LENGTHS)
REFER TO 6054 "INSTALLATION 1"
FOR ATTACHMENT
REQUIREMENTS OF THIS DETAIL
SEE NOTE 3
DECK
NOTE:
WHEN ATTACHING THE PARAPET FLASHING TO THE SUBSTRATE, THE
APPROPRIATE FASTENER MUST BE USED. THE FASTENER FOR THE WALL
FLASHING MAY BE DIFFERENT THAN THE FASTENER USED ON THE HORIZONTAL
ROOF DECKING.
DURO-LAST PREFABRICATED
PARAPET FLASHING
Note: FASCIA BAR AND COVER MAY
BE USED IN PLACE OF TERMINATION
BAR
DECK
REFER TO DETAIL 6010 FOT TAB SPACING
EXISTING ROOF SYSTEM
FLASHING
DURO-LAST PREFABRICATED
PARAPET WALL FLASHING
DURO-LAST APPROVED SLIP
SHEET
EXISTING WALL FLASHING MUST BE
CUT AWAY TO ALLOW
TERMINATION AGAINST SUBTRATE
STRIP MASTIC OR
CAULK
DURO-LAST CAULK
M
IN
Note 1: THIS DETAIL IS ONLY APPLICABLE TO CONCRETE OR BLOCK WALLS.
Note 2: MEMBRANE MUST TERMINATE 8-INCHES (MIN.) FROM THE
SURFACE OF THE ROOF.
DURO-LAST
MEMBRANE
SEALANT
TERMINATION BAR
(FASTEN 6-INCHES
ON CENTER USING
DURO-LAST FASTENERS.)
2 PIECE REGLET
COUNTER FLASHING
RIVET INTO PLACE
(24-INCHES ON
CENTER, MAX.)
LEAD WEDGE AND
CAULK
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AE141
506-330
ANN ARBOR VAMC
OCT. 27, 2017 JK ST
ROOF DETAILS EXPAND 8TH FLOOR
MENTAL HEALTH
SCALE: N.T.S.AE141
TYP. ROOF PIPE SUPPORT DETAIL -
MULTIPLE RUN02
SCALE: N.T.S.AE141
TYP. ROOF PIPE SUPPORT DETAIL -
SINGLE RUN01
SCALE: N.T.S.AE141
ROOF DRAIN W/ OVERFLOW03
SCALE: N.T.S.AE141
ROOF HEAT PIPE FLASHING DETAIL05
SCALE: N.T.S.AE141
ROOF PLENUM VENT INSTALLATION04
SCALE: N.T.S.AE141
ROOF RECTANGULAR
PENETRATION DETAIL07
SCALE: N.T.S.AE141
ROOF ROUND PENETRATION DETAIL06
SCALE: N.T.S.AE141
ROOF SNAP COPING CAP08
SCALE: N.T.S.AE141
ROOF - NEW - PARAPET WALL
FLASHING DETAIL10
SCALE: N.T.S.AE141
ROOF - EXISTING - PARAPET WALL
FLASHING DETAIL11
SCALE: N.T.S.AE141
ROOF - PARAPET WALL
COUNTERFLASHING DETAIL12
1W
ELEV. 826' - 6"
1ST FLOOR
AE300
AE301
AE301
AE301
METAL PANEL
SYSTEM, TYP.
ALUMINUM CURTAIN WALL
SYSTEM, TYP.
EXISTING BUILDING
BEYOND
BRICK VENEER PLANTER
WALL
PARTIAL HEIGHT BRICK
VENEER SCREEN WALL
1.7
SPANDREL GLASS IN
ALUMINUM
CURTAINWALL SYSTEM
COLULMN COVER
A
C
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
20 19 11.92344.1
AE330
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
AE300
I H''H'
AE411
CAST STONE TRIM
CAST STONE SILL
BRICK VENEER ON METAL
STUD BACKUP, REFER TO WALL
TYPES & DETAILS
METAL PANEL
SYSTEM, TYP.
ALUMINUM CURTAIN WALL
SYSTEM, TYP.
EXISTING BUILDING,
BEYOND
E
SPANDREL GLASS IN ALUMINUM
CURTAIN WALL SYSTEM
CDEFGHI
ROOF ACCESS LADDER
FROM HIGH ROOF TO
LOW ROOF
ELEV. 826' - 6"
1ST FLOOR
ELEV. 838' - 5"
2ND FLOOR
AE300
AE301
AE301
/2
/2
TYP.
4' - 0"
TY
P
B.3
METAL PANEL
SYSTEM, TYP.
ALUMINUM CURTAIN WALL
SYSTEM, TYP.
BRICK VENEER PLANTER
WALL
METAL PANEL
SYSTEM, TYP.
SUN SHADE, REFER
TO STRUCTURAL
ALTD-11
AE320
COLUMN COVER
B
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
A B C D E F G
ELEV. 826' - 6"
1ST FLOOR
AE301
AE301
B.3
CAST STONE TRIM
BRICK VENEER ON METAL
STUD BACKUP, REFER TO WALL
TYPES & DETAILS
METAL PANEL
SYSTEM, TYP.
EXISTING BUILDING,
BEYOND
STORM WATER SPOUT; REFEF
TO PLUMBING DRAWINGS
4' - 0"
" ELEV. 848' - 6"
DBE
AB
ROOF ACCESS LADDER
TO HIGH ROOF W/
SECURITY ACCESS AT
GRADE
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
AE301
AE410
AE411
22' 22
/8
/8
CAST STONE TRIM
CAST STONE SILL
BRICK VENEER ON METAL
STUD BACKUP, REFER TO WALL
TYPES & DETAILS
METAL PANEL
SYSTEM, TYP.
ALUMINUM CURTAIN WALL
SYSTEM, TYP.
D
ELEV. 841' - 3"
TOS
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AE200
506-330
ANN ARBOR VAMC
OCT. 27, 2017 JK ST
EXTERIOR ELEVATIONS EXPAND 8TH FLOOR
MENTAL HEALTH
SCALE: 1/4" = 1'-0"AE200
WEST ELEVATION - SOUTH01
SCALE: 1/4" = 1'-0"AE200
NORTH ELEVATION - EAST05
SCALE: 1/4" = 1'-0"AE200
SOUTH ELEVATION02
SCALE: 1/4" = 1'-0"AE200
NORTH ELEVATION - WEST04
SCALE: 1/4" = 1'-0"AE200
WEST ELEVATION - NORTH03
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
AE300
AE301
AE301
AE320
AE320
AE320
AE320
B.3
B184
LOBBY
CB114
CORRIDOR
BB119A
WOMEN'S
SHOWER
BB120
MEN'S
SHOWER
AE320
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
SUNSHADE,
ALTD-11
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
HANDRAIL, BOTH SIDES OF STAIRS
AND MIDDLE; REFER TO
CIVIL DETAILS
ABCDEFGH
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
ELEV. 838' - 5"
2ND FLOOR
AE300
AE301
AE301
AE301
AE410
AE411
AE321
AE301
AE321
AE321
AE321
STAIR
CB81
CORRIDOR CB114
CORRIDOR
CB184C
CORRIDOR
B184A
COFFEE SHOP
B184
LOBBY
BB115
OFFICE
TRAINING
BB32
BIOMED
OFFICE
1.7
AE322
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
4' - 8"
CB106
CORR.
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
20 19 11.92344.157
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AE300
506-330
ANN ARBOR VAMC
OCT. 27, 2017 JK ST
BUILDING SECTIONS EXPAND 8TH FLOOR
MENTAL HEALTH
SCALE: 3/16" = 1'-0"AE300
BUILDING SECTION01
SCALE: 3/16" = 1'-0"AE300
BUILDING SECTION02
ELEV. 826' - 6"
1ST FLOOR
AE300
AE301
AE301
AE323
AE323
BB120A
MEN'S LOCKER
BB120
MEN'S
SHOWER
1.7
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
2019 1.9 2 3 4 4.1
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
AE300
J
AE301
AE323
B.3
CB184V
VESTIBULE
B184
LOBBY
CB184
WAITING
BB70
STAFF GYM
BB32
BIOMED
OFFICE
BB117
OPEN OFFICE
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
ELEV. 848' - 6"
DBE
ELEV. 835' - 10 1/2"
BSE/TOP OF PL
ABCDEFGH
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
ELEV. 838' - 5"
2ND FLOOR
AE300
AE301
AE301
AE301
AE324
AE324
AE324
B184
LOBBY
B184A
COFFEE SHOP
CB184V
VESTIBULE
CB114
CORRIDOR
BB112
HOLDING
BB110
INTERVIEW
BB108
EVIDENCE
1.7
BB117
OPEN OFFICE
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
ELEV. 848' - 6"
DBE
ROOF ACCESS LADDER
TO HIGH ROOF W/
SECURITY ACCESS AT
GRADE
ELEV. 841' - 3"
TOS
20191 1.9 2 3 44.1 5
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
AE300
J
AE411
AE322
AE322
CB184C
CORRIDOR
BB105
OFFICE PHYS
SEC
BB74
TOILET
C3
CORRIDOR
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
ELEV. 841' - 3"
TOS
C D E F G H I
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
AE300
AE301
AE301
AE322
B.3
B184
LOBBY
B184A
COFFEE SHOP
BB111
OFFICE CHIEF
BB110
INTERVIEW
BB118
TRAINING/BREAK
BB120A
MEN'S LOCKER
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
ALTD-11
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
A B C D E F G H I
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
AE300
AE301
AE301
AE322
AE323
B.3
B184
LOBBY
BB113
OFFICE DEPUTY
BB112
HOLDING
BB118
TRAINING/BREAK
BB120A
MEN'S LOCKER
AE320
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC IN
PEA STONE BED; REFER TO
CIVIL/PLUMBING
ALTD-11
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
ELEV. 843' - 9"
TOP OF TUBE STEEL
ABCDEFGH
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AE301
506-330
ANN ARBOR VAMC
OCT. 27, 2017 JK ST
BUILDING SECTIONS EXPAND 8TH FLOOR
MENTAL HEALTH
SCALE: 1/8" = 1'-0"AE301
BUILDING SECTION01
SCALE: 1/8" = 1'-0"AE301
BUILDING SECTION02
SCALE: 1/8" = 1'-0"AE301
BUILDING SECTION03
SCALE: 1/8" = 1'-0"AE301
BUILDING SECTION04
SCALE: 1/8" = 1'-0"AE301
BUILDING SECTION05
SCALE: 1/8" = 1'-0"AE301
BUILDING SECTION06
E'
PEDESTAL PAVER SYSTEM:
2" PAVERS ON PRE-MANUFACTURED
ADJUSTABLE HEIGHT PEDESTAL
SYSTEM
PAVER COPING STAIR TREADS
CONCRETE STAIR SYSTEM ON
COMPACTED FILL
2" RIGID INSULATION (MIN. R-7.5)
WATERPROOFING
CONCRETE FOUNDATION SYSTEM -
REFER TO STRUCTURAL DRAWINGS
SINGLE-PLY ROOFING MEMBRANE
ON 1/2" COVER BOARD ON (2)
LAYERS 2" RIGID INSULATION (MIN.
R-20) AND TAPERED INSULATION
TO SLOPE TO ROOF DRAIN
WATERPROOFING MEMBRANE
(REFER TO NOTE) WRAP UP AND
OVER FOUNDATION WALL
CONCRETE ROOF DECK
ON STEEL DECK
4" CONCRETE SLAB ON VAPOR
BARRIER OVER 6" MIN.
COMPACTED GRANULAR FILL
1/2" PRE-MOLDED EXPANSION
JOINT MATERIAL
2" RIGID INSULATION VERTICAL
PVC WATERSTOP; TYP.
SURFACE APPLIED WATERSTOP
SPRAY APPLIED
INSULATION TO UNDERSIDE
OF ROOF DECK (MIN. R-18)
5/8" GYP. BOARD ON STEEL STUD
WITH MINERAL WOOL BATT
INSULATION - SEE WALL TYPES SHEET
5/8" GYP. BOARD ON STEEL STUD
FRAMING @ 16" O.C. MAX
WATERPROOFING MEMBRANE NOTE:
APPLY ON CONCRETE - PRIMER OR
CONTACT ADHESIVE, 90 MILLS HOT
APPLIED LIQUID MEMBRANE,
REINFORCING FABRIC, 125 MILLS HOT
APPLIED LIQUID MEMBRANE,
PROTECTION BOARD, DRAINAGE
COMPOSITE
PATIO ELEVATION @ STAIR
826.62'
BASEMENT FLOOR SLAB
815'-6"
FILTER FABRIC WRAPPED
6" DIA. SLOTTED PVC DRAIN
IN PEA STONE BED, REFER TO
CIVIL/PLUMBING
1-1/4" SQUARE TUBE STEEL
HANDRAIL, REFER TO CIVIL FOR
DETAILS
18 ga. CUSTOM METAL
COPING TO MATCH, BY
RAINSCREEN MANUFACTURER
(2) LAYERS P.T. PLYWOOD
1-1/2" METAL PANEL RAINSCREEN
SYSTEM ON 2" RIGID MINERAL
WOOL BOARD ON AIR/MOISTURE
BARRIER ON 5/8" EXT. GYP.
BOARD SHEATHING ON COLD
FORMED METAL FRAMING - REFER
TO STRUCTURAL
HEMMED DRIP EDGE AND SEALANT
P.T. 2x BLOCKING
ROOF MEMBRANE ON 1/2" COVER
BOARD ON (3) LAYERS 2" (MIN. R-30)
RIGID INSULATION MECHANICALLY
FASTENED TO 1-1/2" STEEL ROOF DECK
RUN ROOF MEMBRANE UP
AND OVER INSULATION
P.T. 2x BLOCKING
CONTINUOUS AIR/MOISTURE
BARRIER
2 PIECE COLUMN COVER
TO MATCH METAL PANEL
RAINSCREEN BEYOND
STRUCTURAL STEEL FRAMING
MEMBERS (REFER TO STRUCTURAL)
FIBER SPRAYED FIREPROOFING
PER UL X772 (2 HR.)
B.O.D. HIGH ROOF
848'-6"
TOP OF PARAPET
850'-7 1/2"
A
SLOPE, 1/4"/FT
6"
1' - 4"
/2
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
SINGLE-PLY ROOFING MEMBRANE
ON 1/2" COVER BOARD ON (2)
LAYERS 2" RIGID INSULATION (MIN.
R-20) AND TAPERED INSULATION
TO SLOPE TO ROOF DRAIN
WATERPROOFING MEMBRANE
(REFER TO NOTE THIS SHEET)
CONCRETE ROOF DECK ON STEEL
DECK
4" CONCRETE SLAB ON VAPOR
BARRIER OVER 6" MIN.
COMPACTED GRANULAR FILL
PEDESTAL PAVER SYSTEM: 2"
PAVERS ON PRE-MANUFACTURED
ADJUSTABLE HEIGHT PEDESTAL
SYSTEM
5/8" GYP. BOARD BOTH SIDES OF
STEEL STUD WITH SOUND BATT
INSULATION - SEE WALL TYPES SHEET
CONCRETE FOUNDATION - REFER
TO STRUCTURAL DRAWINGS
7 1/2" STRUCTURALLY REINFORCED
ALUMINUM CURTAINWALL SYSTEM
WITH 1" INSULATED LOW 'E' GLAZING
EXPOSED STEEL COLUMN - PRIMED
AND PAINTED WITH INTUMESCENT
PAINT PER UL X661 (2 HR.)
STEEL STRUCTURE W/ FIBER SPRAYED
FIREPROOFING PER UL X771 (2 HR.)
HEATING SYSTEM - REFER TO
MECHANICAL DRAWINGS
LINE OF PLANTER BEYOND
GYP. BD. ON STEEL STUD FRAMING
@ 16" O.C. MAX
1-1/2" METAL PANEL RAINSCREEN
SYSTEM ON 2" RIGID MINERAL WOOL
BOARD (MIN. R-7.5 CONTINUOUS) ON
AIR/MOISTURE BARRIER ON 5/8" EXT.
GYP. BOARD SHEATHING ON COLD
FORMED METAL FRAMING - REFER TO
STRUCTURAL
MEMBRANE ROOF ON 1/2"
COVER BOARD ON (3) LAYERS
2" RIGID INSULATION (MIN. R-
30)MECHANICALLY FASTENED
TO 1-1/2" STEEL ROOF DECK
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
SILL TRIM
AE320
PVC WATERSTOP
STRUCTURAL STEEL FRAMING
MEMBERS (REFER TO STRUCTURAL)
W/ SPRAYED FIREPROOFING PER
UL X772
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
DEFLECTION CLIP
CONCRETE SLAB ON
STEEL DECK
GYP. BD. ON STEEL STUD FRAMING
@ 16" O.C. MAX
5/8" GYP. BD. ON COLD FORMED
METAL FRAMING (FILL ENTIRE
CAVITY W 6" MINERAL WOOL BATT
INSULATION - MIN. R-13)
1-1/2" METAL PANEL RAINSCREEN
SYSTEM ON 2" RIGID MINERAL WOOL
BOARD ON AIR/MOISTURE BARRIER
ON 5/8" EXT. GYP. BOARD SHEATHING
ON COLD FORMED METAL FRAMING -
REFER TO STRUCTURAL
5/8" GYP. WALL BOARD ON
METAL STUD FRAMING
SPRAY APPLIED INSULATION TO
UNDERSIDE OF ROOF DECK
(MIN. R-18)
STEEL STRUCTURE W/ FIBER SPRAYED
FIREPROOFING PER UL X772 (2 HR.)
CORNER GUARD BEYOND, TYP.
AE332
AE332
ELEV. 848' - 6"
DBE
ELEV. 843' - 9"
TOP OF TUBE STEEL
B
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
SINGLE PLY ROOF MEMBRANE ON 1/2"
COVER BOARD ON (3) LAYERS 2" RIGID
INSULATION (MIN. R-30)
MECHANICALLY FASTENED TO 1-1/2"
STEEL ROOF DECK
WRAP ROOF MEMBRANE UP
EXISTING WALL AND TERMINATE
W/ REGLET COUNTERFLASHING
AND TERMINATION BAR
STRUCTURAL STEEL (REFER TO
STRUCTURAL) W/ FIBER SPRAYED
FIREPROOFING PER UL X772 (2 HR.)
5/8" GYP. BD. ON METAL STUD
FRAMING @ 16" O.C. MAX.
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
STRUCTURAL STEEL (REFER TO
STRUCTURAL) W/ FIBER SPRAYED
FIREPROOFING PER UL X772 (2 HR.)
STRUCTURAL STEEL (REFER TO
STRUCTURAL) W/ FIBER SPRAYED
FIREPROOFING PER UL X772 (3 HR.)
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
CONCRETE SLAB ON STEEL DECK;
REFER TO STRUCTURAL
5/8" GYP. BOARD ONE SIDE ON
STEEL STUD FRAMING - SEE WALL
TYPES SHEET AI500
V
IF
COMPRESSIBLE TUBE
EXPANSION JOINT W/ COMPRESSIBLE
INSULATION AND INSULATION
RETAINER; MAINTAIN FIRE RATING
PER UL 2079 (1.5-HR)
FIBER-REINFORCED PANEL ON 5/8"
GYP. BD. ON METAL STUDS; REFER
TO WALL TYPES
FIRE RATED EXPANSION JOINT
UL 2079 (2 HR.)
1 1/2"
FACE OF EXISTING WALL
CONCRETE SLAB ON STEEL DECK;
REFER TO STRUCTURAL
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
FG
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
1.7
SINGLE PLY ROOF MEMBRANE ON
1/2" COVER BOARD ON (3) LAYERS
2" RIGID INSULATION (MIN. R-30)
MECHANICALLY FASTENED TO 1-
1/2" STEEL ROOF DECK
1-1/2" METAL PANEL RAINSCREEN
SYSTEM ON 2" RIGID MINERAL
WOOL BOARD ON AIR/MOISTURE
BARRIER ON 5/8" EXT. GYP. BOARD
ON COLD FORMED METAL
FRAMING - REFER TO STRUCTURAL
(2) LAYERS P.T. PLYWOOD
18 ga. CUSTOM METAL
COPING TO MATCH, BY
RAINSCREEN MANUFACTURER
P.T. 2x BLOCKING
RUN ROOF MEMBRANE UP AND
OVER PLYWOOD
HEMMED DRIP EDGE AND
SEALANT
CONTINUOUS AIR/ MOISTURE
BARRIER
P.T. 2x BLOCKING
STRUCTURAL STEEL FRAMING
MEMBERS (REFER TO STRUCTURAL)
WITH SPRAYED FIREPROOFING -
PER UL X772 (2 HR.)
EXPOSED GALVANIZED STEEL
COLUMN - PRIMED AND PAINTED
WITH INTUMESCENT PAINT PER
UL X661 (2 HR.)
1-1/2" METAL PANEL RAINSCREEN SYSTEM ON
2" RIGID MINERAL WOOL BOARD (MIN. R-7.5
CONTINUOUS) ON AIR/MOISTURE BARRIER ON
5/8" EXT. GYP. BOARD ON COLD FORMED
METAL FRAMING
5/8" GYP. BOARD ON COLD FORMED
METAL FRAMING (FILL ENTIRE CAVITY
W/ 6" MINERAL WOOL BATT
INSULATION MIN. R-13)
STRUCTURAL STEEL FRAMING
MEMBERS (REFER TO STRUCTURAL)
WITH SPRAYED FIREPROOFING PER
UL X771 (2 HR.)
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
SILL TRIM
7 1/2" STRUCTURALLY REINFORCED ALUMINUM
CURTAINWALL SYSTEM WITH 1" INSULATED LOW
'E' GLAZING
CAST STONE UNIT W/ CONTINUOUS
DRIP EDGE
CONTINUOUS SILL FLASHING W/ WEEPS
STANDARD BRICK VENEER ON AIR SPACE
WITH 4" RIGID MINERAL WOOL BOARD
(MIN. R???) ON AIR/ MOISTURE BARRIER
ON CMUs (REFER TO STRUCTURAL)
ADJUSTABLE MASONRY TIES; SEE SPEC FOR
SPACING
CAVITY DRAINAGE MATERIAL
CELLULAR PLASTIC WEEP INSERTS @ 24"
O.C. IN OPEN HEAD JOINT
PEDESTAL PAVER SYSTEM: 2" PAVERS ON
PRE-MANUFACTURED ADJUSTABLE HEIGHT
PEDESTAL SYSTEM
SINGLE PLY ROOFING MEMBRANE
ON 1/2" COVER BOARD ON (2)
LAYERS 2" RIGID INSULATION (MIN.
R-20) AND TAPERED INSULATION
TO SLOPE TO ROOF DRAIN
THROUGH WALL BASE FLASHING;
GROUT SOLID BELOW
4" CONCRETE SLAB ON 6" MIN.
COMPACTED FILL
VAPOR BARRIER OVER FILL
GROWING MEDIUM ON
FILTER MEMBRANE
DRAINAGE MEMBRANE ON
WATERPROOFING MEMBRANE;
WRAP UP AND UNDER CAST STONE
EXPANDED POLYSTYRENE GEOFOAM
LIGHTWEIGHT FILL
PVC WATERSTOP
5/8" GYPSUM WALL BOARD ON
METAL STUD FRAMING
STRUCTURAL STEEL FRAMING
MEMBERS (REFER TO STRUCTURAL)
WITH SPRAYED FIREPROOFING PER
UL X772 (3 HR.)
SPRAY APPLIED INSULATION TO
UNDERSIDE OF ROOF DECK
(MIN. R-18)
BULKHEAD - 5/8" GYP. BOARD ON
METAL STUDS
WATERPROOFING MEMBRANE
(REFER TO NOTE THIS SHEET)
AE332
CORNER GUARD ON PIER, TYP.
ELEV. 848' - 6"
DBE
ELEV. 843' - 9"
TOP OF TUBE STEEL
1.9 2
1' - 9"
SLOPE, 1/4"/FT
A T
H
IG
H R
O O
F
5 1/2"8 1/2"
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AE320
506-330
ANN ARBOR VAMC
OCT. 27, 2017 JK MH
WALL SECTIONS EXPAND 8TH FLOOR
MENTAL HEALTH
SCALE: 3/4" = 1'-0"AE320
WALL SECTION01
SCALE: 3/4" = 1'-0"AE320
TYP. HIGH ROOF PARAPET02
SCALE: 3/4" = 1'-0"AE320
WALL SECTION03
SCALE: 3/4" = 1'-0"AE320
WALL SECTION04
SCALE: 3/4" = 1'-0"AE320
WALL SECTION05
EXISTING WALL
CONSTRUCTION
MEMBRANE ROOFING SYSTEM FULLY
ADHERED TO 1/2" COVERBOARD ON (3)
LAYERS 2" RIGID INSULATION (MIN. R-30)
MECHANICALLY FASTENED TO 1-1/2"
STEEL ROOF DECK
WRAP MEMBRANE UP EXISTING WALL AND
TERMINATE W/ REGLET COUNTERFLASHING
AND TERMINATION BAR
STEEL STRUCUTRE WITH FIBER
SPRAYED FIREPROOFING PER
UL X771 (2 HR.)
STEEL STRUCTURE WITH FIBER
SPRAYED FIREPROOFING PER
UL X772 (2 HR.)
CONCRETE SLAB ON STEEL DECK
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
5/8" GYP. BOARD ON STEEL STUD -
SEE WALL TYPES SHEET
4" CONCRETE SLAB ON VAPOR
BARRIER OVER 6" MIN.
COMPACTED GRANULAR FILL
STEEL STRUCTURE WITH FIBER
SPRAYED FIREPROOFING PER
UL X772 (3 HR.)
COMPRESSIBLE TUBE
EXPANSION JOINT W/
COMPRESSIBLE INSULATION AND
INSULATION RETAINER; MAINTAIN
FIRE RATING PER UL 2079 (1.5 HR)
V
IF
1 1/2"
FIRE RATED EXPANSION JOINT
UL 2079 (2 HR.)
B.O.D.- HIGH ROOF
848'-6"
T.O. TUBE STEEL
841'-3"
FIRST FLOOR SLAB
826'-6"
BASEMENT FLOOR SLAB
815'-6"
EXIST. THIRD FLR.
849'-5"
EXISTING WALL
CONSTRUCTION TO
REMAIN
EXISTING WALL
CONSTRUCTION
EXISTING WALL
CONSTRUCTION
AE301
MEMBRANE ROOFING SYSTEM FULLY
ADHERED TO 1/2" COVERBOARD ON (3)
LAYERS 2" RIGID (MIN. R-30) INSULATION
MECHANICALLY FASTENED TO 1-1/2"
STEEL ROOF DECK
SUSPENDED ACOUSTIC PANEL CEILING
IN METAL TEE GRID
5/8" GYP. BD. (ROOM SIDE) ON 3-5/8"
METAL STUDS @ 16" O.C.; FILL ENTIRE
CAVITY WITH SOUND BATT INSULATION
3-5/8" METAL STUD BRACING @ 4'-0"
O.C. (MAX.)
3-5/8" METAL STUD BRACING @ 4'-0"
O.C. (MAX.)
/4
VERTICAL LINEAR PLANK ON VERTICAL
FLEECE
LINEAR PLANK ON LINEAR FLEECE ON
LINEAR CARRIER SPACE 24" O.C. (MAX.)
ELEV. 848' - 6"
DBE
SECURITY GATE, REFER TO CEILING
DETAILS SHEET AI530
SUSPENDED ACOUSTIC PANEL CEILING
IN METAL TEE GRID
GYP. BD. CORNER TRIM, TYP. ALL
EXPOSED OUTSIDE CORNERS
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
2x P.T. BLOCKINGINTEGRAL METAL PANEL COPING COVER
ON ANCHOR CLIPS; SIZE AND SPACING
PER COPING CAP MANUFACTURER
P.T. 2x6 BLOCKING
MEMBRANE ROOF FULLY ADHERED ON
1/2" COVERBOARD ON (3) LAYERS 2"
RIGID INSULATION (MIN. R-30)
MECHANICALLY FASTENED TO 1-1/2"
STEEL ROOF DECK
STEEL STRUCTURE WITH FIBER SPRAY
FIREPROOFING PER UL X772 (2 HR.)
RUN ROOF MEMBRANE UP AND OVER
PARAPET
1-1/2" METAL PANEL RAINSCREEN
SYSTEM ON 2" RIGID MINERAL WOOL
BOARD (MIN. R-7.5 CONTINUOUS)
ON AIR/MOISTURE BARRIER ON 5/8"
GLASS MATT EXT. GYP. BOARD ON
COLD FORMED METAL FRAMING -
REFER TO STRUCTURAL
MEMBRANE ROOF FULLY ADHERED
TO 1/2" COVERBOARD ON (3)
LAYERS 2" RIGID INSULATION (MIN.
R-30) MECHANICALLY FASTENED TO
1-1/2" STEEL ROOF DECK
RUN ROOFING UP AND BEHIND
METAL PANEL
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
5/8" GYP. BD. ON COLD
FORMED METAL FRAMING
(FILL ENTIRE CAVITY W/ 6"
MINERAL WOOL BATT
INSULATION - MIN. R-13)
CONCRETE SLAB ON STEEL DECK
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
4" CONCRETE SLAB ON VAPOR
BARRIER OVER 6" MIN.
COMPACTED GRANULAR FILL
5/8" GYP. BD. (BOTH SIDES) ON
COLD FORMED METAL
FRAMING (FILL ENTIRE CAVITY
W/ 6" SOUND INSULATION)
STEEL STRUCTURE WITH FIBER SPRAY
FIREPROOFING PER UL X772 (2 HR.)
STEEL STRUCTURE WITH FIBER SPRAY
FIREPROOFING PER UL X772 (3 HR.)
AE332
ELEV. 848' - 6"
DBE
ELEV. 841' - 3"
TOS
44.1
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
18 ga. CUSTOM METAL
COPING TO MATCH, BY
RAINSCREEN MANUFACTURER
(2) LAYERS P.T. PLYWOOD
1-1/2" METAL PANEL RAINSCREEN
SYSTEM ON 2" RIGID MINERAL
WOOL BOARD ON AIR/MOISTURE
BARRIER ON 5/8" EXT. GYP. BOARD
ON COLD FORMED METAL
FRAMING - REFER TO STRUCTURAL
EXPOSED STEEL COLUMN -
PRIMED AND PAINTED
WITH INTUMESCENT PAINT
PER UL X661 (2 HR.)
HEMMED DRIP EDGE AND
SEALANT
P.T. 2x BLOCKING
SINGLE PLY ROOF MEMBRANE ON 1/2"
COVER BOARD ON (3) LAYERS 2" RIGID
INSULATION (MIN. R-30) ON 1-1/2" STEEL
ROOF DECK
RUN ROOF MEMBRANE UP
AND OVER INSULATION
P.T. 2x BLOCKING
CONTINUOUS AIR/MOISTURE
BARRIER WRAP OVER CORNICE
STRUCTURAL STEEL FRAMING
MEMBERS (REFER TO STRUCTURAL)
WITH FIREPROOFING PER ULX772
(2 HR.)
7 1/2" STRUCTURALLY REINFORCED
ALUMINUM CURTAINWALL SYSTEM
W/ 1" INSULATED LOW 'E' GLAZING
STANDARD BRICK VENEER ON AIR
SPACE WITH 2" RIGID MINERAL
WOOL BOARD (MIN. R-7.5
CONTINUOUS) ON AIR/ MOISTURE
BARRIER ON GLASS MAT EXTERIOR
GRADE GYP. BOARD
CAST STONE UNIT
THRU-WALL FLASHING AND CELLULAR
PLASTIC WEEPS @ 24" O.C. (MAX.)
GALVANIZED STEEL LINTEL (PAINTED) -
REFER TO STRUCTURAL DRAWINGS
CONCRETE STAIR IN
METAL PAN SYSTEM
4" CONCRETE SLAB ON VAPOR
BARRIER OVER 6" MIN.
COMPACTED GRANULAR FILL
1/2" PRE-MOLDED EXPANSION
JOINT MATERIAL
2" RIGID INSULATION
EXPOSED STEEL BEAM -
PRIMED AND PAINTED
WITH INTUMESCENT PAINT
PER UL X660 (2 HR.)
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
CAST STONE UNIT W/
CONTINUOUS DRIP (CENTER
ON WINDOW W/ EQUAL ENDS)
GALVANIZED STEEL VERTICAL
CURTAINWALL DEAD LOAD
SUPPORT; REFER TO STRUCTURAL
STANDARD BRICK VENEER ON AIR
SPACE WITH 2" RIGID INSULATION
(MIN. R-7.5 CONTINUOUS) ON AIR/
MOISTURE BARRIER ON EXTERIOR
GRADE GYP. BOARD SHEATHING
GALVANIZED STEEL HEADER,
FILL ENTIRE CAVITY W/ BATT
INSULATION; SEE STRUCTURAL
CAVITY DRAINAGE MATERIAL
3 5/8"
2 3/4"
2"
5/8"
6" 5/8"
1' - 3 5/8"
P.T. 2x BLOCKING
CONTINUOUS SILL FLASHING
W/ WEEPS
CAVITY DRAINAGE MATERIAL
ADJUSTABLE MASONRY TIES; SEE
SPEC FOR SPACING
THROUGH WALL BASE FLASHING;
GROUT SOLID BELOW
CELLULAR PLASTIC WEEP INSERTS
@ 24" O.C. IN OPEN HEAD JOINT
5/8" GYPSUM BOARD ON 6"
COLD FORMED METAL FRAMING;
SEE STRUCTURAL. FILL ENTIRE
CAVITY WITH MINERAL WOOL
BATT INSULATION (MIN. R-13)
WATERPROOFING
2" RIGID INSULATION
REINFORCED FOUNDATION;
REFER TO STRUCTURAL
AE332
5/8" GYP. BOARD ON COLD
FORMED METAL FRAMING (FILL
ENTIRE CAVITY W/ 6" MINERAL
WOOL BATT INSULATION - MIN. R-13)
CURTAINWALL ALUMINUM
INFILL PANEL (MATCH
FRAMING FINISH)
SLOPE
AE332
REFER TO CIVIL
INSULATED SPANDREL GLASS IN
ALUMINUM CURTAINWALL SYSTEM
ELEV. 841' - 3"
TOS
ELEV. 835' - 10 1/2"
BSE/TOP OF PL
7 1/2" STRUCTURALLY REINFORCED
ALUMINUM CURTAINWALL SYSTEM
W/ 1" INSULATED LOW 'E' GLAZING
EXPOSED STEEL COLUMN -
PRIMED AND PAINTED
WITH INTUMESCENT PAINT
PER UL X661 (2 HR.)
2 1/2"
A T
LO
W
R O
O F
3 1/2"
1811 4 Mile Rd N.E., Grand Rapids, MI 49525 www.progressiveae.com
616 361 2664 OFFICE 616 361 1493 FAX
architecture +engineering
SEVEN
GENERATIONS
4664 Campus Drive, Suite 101
Kalamazoo, MI 49008
P: 269.927.0144 www.7GenAE.com
2 3 4 5 6 7 8 9
2 3 4 5 6 7 8 91
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANTS ARCHITECT/ENGINEERS
DRAWING TITLE:
APPROVED: PROJECT DIRECTOR LOCATION
PROJECT TITLE:
DATE: CHECKED: DRAWN:
PROJECT NUMBER:
BUILDING NUMBER:
DRAWING NUMBER:
DWG. ___ OF ___
7GAE PROJECT NO.: XXXXXX FILE NAME: TITL-BLK-3042-VA.DWG
Office of
Construction and Facilities
Management
VA FORM 08-6231
o n e e ig h th i n c h o e q u a rt e r in c h o e e ig h th s in c h o e h a lf i n c h o e q u a rt e rs i n c h o e i n c h o e a n d o n e h a lf i n c h e s o e i n c h e s o
6 "
Department of Veterans Affairs
68 East Michigan Ave.
Battle Creek, MI 49017
P: 269.224.3182 www.wbkengineering.com
451 Hungerford Dr. 4th Floor
Rockville, MD 20850
P: 301.770.3520 F: 301.770.3521 www.nikasolutions.com
AE321
506-330
ANN ARBOR VAMC
OCT. 27, 2017 JK MH
WALL SECTIONS EXPAND 8TH FLOOR
MENTAL HEALTH
SCALE: 3/4" = 1'-0"AE321
WALL SECTION01
SCALE: 3/4" = 1'-0"AE321
WALL SECTION02
SCALE: 3/4" = 1'-0"AE321
WALL SECTION03
SCALE: 3/4" = 1'-0"AE321
WALL SECTION04
ELEV. 826' - 6"
1ST FLOOR
EXISTING EXTERIOR
WALL CONSTRUCTION
WRAP MEMBRANE UP EXISTING WALL AND
TERMINATE W/ REGLET COUNTERFLASHING
AND TERMINATION BAR
MEMBRANE ROOFING SYSTEM FULLY
ADHERED TO 1/2" COVERBOARD ON (3)
LAYERS 2" RIGID INSULATION (MIN. R-30)
MECHANICALLY FASTENED TO 1-1/2"
STEEL ROOF DECK
STEEL STRUCTURE (REFER TO
STRUCTURAL) WITH FIBER
SPRAYED FIREPROOFING
PER UL X772 (2 HR.)
SUSPENDED ACOUSTIC
PANEL CEILING IN METAL
TEE GRID
CONCRETE SLAB ON
STEEL DECK
5/8" TYPE 'X' GYP. BOARD
EACH SIDE ON METAL
STUDS W/ SOUND BATT
INSULATION - SEE WALL
TYPES SHEET
5/8" GYP. BOARD ON METAL STUDS
SEE WALL TYPES SHEET
STEEL STRUCTURE WITH 4-1/2" MIN.
FIBER SPRAYED FIREPROOFING
COMPRESSIBLE TUBE
EXPANSION JOINT W/
COMPRESSIBLE INSULATION
AND INSULATION RETAINER;
MAINTAIN FIRE RATING PER UL
2079 (1.5-HR)
FIRE RATED EXPANSION JOINT
UL 2079 (2 HR.)
STEEL STRUCTURE (REFER TO
STRUCTURAL) WITH FIBER
SPRAYED FIREPROOFING
PER UL X772 (3 HR.)
EXISTING EXTERIOR
WALL CONSTRUCTION
EXISTING EXTERIOR
WALL CONSTRUCTION
BOD LOW ROOF
841'-3"
F G H I
ELEV. 815' - 6"
BASEMENT
18 ga. CUSTOM METAL
COPING TO MATCH, BY
RAINSCREEN MANUFACTURER
(2) LAYERS P.T. PLYWOOD
1-1/2" METAL PANEL RAINSCREEN SYSTEM
ON 2" RIGID MINERAL WOOL BOARD ON
AIR/MOISTURE BARRIER ON 5/8" EXT. GYP.
BOARD SHEATHING ON COLD FORMED
METAL FRAMING - REFER TO STRUCTURAL
SUSPENDED ACOUSTIC
PANEL CEILING IN METAL
TEE GRID
HEMMED DRIP EDGE AND
SEALANT
P.T. 2x BLOCKING
ROOF MEMBRANE ON 1/2"
COVER BOARD ON (3) LAYERS
2" RIGID INSULATION (MIN. R-
30) MECHANICALLY FASTENED
TO 1-1/2" STEEL ROOF DECK
RUN ROOF MEMBRANE UP
AND OVER INSULATION
P.T. 2x BLOCKING
CONTINUOUS AIR/MOISTURE
BARRIER
STRUCTURAL STEEL
FRAMING MEMBERS WITH
SPRAYED FIREPROOFING
PER UL X772 (2 HR.)
7 1/2" STRUCTURALLY REINFORCED
ALUMINUM CURTAINWALL SYSTEM
WITH 1" INSULATED LOW 'E' GLAZING
STANDARD BRICK VENEER ON AIR SPACE
WITH 2" RIGID MINERAL WOOL BOARD
(MIN. R-7.5 CONTINUOUS) ON AIR/
MOISTURE BARRIER ON 5/8" EXT. GYP.
BOARD SHEATHING
CAST STONE UNIT
THRU-WALL FLASHING AND WEEPS
STEEL LINTEL - REFER TO
STRUCTURAL DRAWINGS
CAST STONE UNIT
THROUGH WALL BASE FLASHING
(REFER TO CIVIL FOR HEIGHT);
GROUT SOLID BELOW
2" RIGID INSULATION
(MIN. R-7.5)
WATERPROOFING
CONCRETE FOUNDATION
SYSTEM - REFER TO
STRUCTURAL DRAWINGS
CONCRETE SLAB ON STEEL
DECK
4" CONCRETE SLAB ON 6" MIN.
COMPACTED FILL
VAPOR BARRIER OVER FILL
1/2" PRE-MOLDED EXPANSION
JOINT MATERIAL
2" RIGID INSULATION VERTICAL
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
GALVANIZED STEEL; REFER
TO STRUCTURAL
EXPOSED STEEL COLUMN -
PRIMED AND PAINTED
WITH INTUMESCENT PAINT
PER UL X661 (2 HR.)
3 5/8"
5/8"
6" 5/8"
1' - 3 5/8"
"CONTINUOUS SILL FLASHING
W/ WEEPS
5/8" GYP. BOARD ON COLD
FORMED METAL FRAMING
(FILL ENTIRE CAVITY W/ 6"
MINERAL WOOL BATT
INSULATION MIN. R-13)
STANDARD BRICK VENEER ON AIR SPACE
WITH 2" RIGID MINERAL WOOL BOARD
(MIN. R-7.5 CONTINUOUS) ON AIR/
MOISTURE BARRIER ON 5/8" EXT. GYP.
BOARD SHEATHING
HEATING SYSTEM - REFER
TO MECHANICAL
REFER TO CIVIL
5/8" GYP. BD. ON COLD
FORMED METAL FRAMING
(FILL ENTIRE CAVITY W/ 6"
MINERAL WOOL BATT
INSULATION - MIN. R-13)
CELLULAR PLASTIC WEEP INSERTS
@ 24" O.C. IN OPEN HEAD JOINT
CAVITY DRAINAGE MATERIAL
5/8" GYP. BOARD (ROOM SIDE) W/
MINERAL WOOL BATT INSULATION
(MIN. R-13) - SEE WALL TYPES
/8
6"
8"
BSE/TOP OF PLATE
835'-10 1/2"
TOP OF TUBE STEEL
831'-1"
FIRST FLOOR
826'-6"
BRICK LEDGE
824'-6"
BOTTOM OF STEEL DECK
841'-3"
EXPANSION
MATERIAL/JOINT
D E
A T
LO
W
R O
O F
2 1/2"
GALVANIZED STEEL HEADER,
FILL ENTIRE CAVITY W/ BATT
INSULATION; SEE STRUCTURAL
3"
6 1/2"
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
4" CONCRETE SLAB ON 6" MIN.
COMPACTED GRANULAR FILL
VAPOR BARRIER OVER FILL
CONCRETE ROOF DECK
ON METAL DECKING
WATERPROOFING
MEMBRANE (REFER TO
NOTE AE320)
SINGLE-PLY ROOFING
MEMBRANE ON 1/2" COVER
BOARD ON (2) LAYERS 2" RIGID
INSULATION (MIN. R20) AND
TAPERED INSULATION TO SLOPE
TO ROOF DRAIN
PEDESTAL PAVER SYSTEM: 2"
PAVERS ON PRE-MANUFACTURED
ADJUSTABLE HEIGHT PEDESTAL
SYSTEM
HEATING SYSTEM - REFER TO
MECHANICAL DRAWINGS
INSULATED SPANDREL GLAZING IN
ALUMINUM CURTAINWALL SYSTEM,
REFER TO ELEVATIONS
SILL TRIM
SUSPENDED ACOUSTIN PANEL
CEILING IN METAL TEE GRID
SINGLE PLY ROOF MEMBRANE ON
1/2" COVER BOARD ON (3) LAYERS
2" RIGID INSULATION (MIN. R-30)
MECHANICALLY FASTENED TO 1-1/2"
STEEL ROOF DECK
STEEL STRUCTURE WITH FIBER
SPRAY FIREPROOFING PER
UL X772 (2 HR.)
1-1/2" METAL PANEL RAINSCREEN
SYSTEM ON 2" RIGID MINERAL WOOL
BOARD ON AIR/ MOISTURE BARRIER
ON 5/8" EXT. GYP. BOARD SHEATHING
ON COLD FORMED METAL FRAMING -
REFER TO STRUCTURAL
SPRAY APPLIED
INSULATION TO UNDERSIDE
OF ROOF DECK (MIN. R-18)
STEEL STRUCTURE WITH FIBER
SPRAY FIREPROOFING PER
UL X771 (2 HR.)
STEEL STRUCTURE WITH FIBER
SPRAY FIREPROOFING PER
UL X771 (3 HR.)
ELEV. 848' - 6"
DBE
ELEV. 843' - 9"
TOP OF TUBE STEEL
B
7 1/2" STRUCTURALLY REINFORCED
ALUMINUM CURTAINWALL SYSTEM
WITH 1" INSULATED LOW 'E' GLAZING,
REFER TO ELEVATIONS
ELEV. 815' - 6"
BASEMENT
ELEV. 826' - 6"
1ST FLOOR
PEDESTAL PAVER SYSTEM:
2" PAVERS ON PRE-
MANUFACTURED ADJUSTABLE
HEIGHT PEDESTAL SYSTEM
CONCRETE STAIR SYSTEM ON
COMPACTED FILL BEYOND
2" RIGID INSULATION
CONCRETE FOUNDATION SYSTEM -
REFER TO STRUCTURAL DRAWINGS
SINGLE-PLY ROOFING MEMBRANE
ON 1/2" COVER BOARD ON (2)
LAYERS 2" RIGID INSULATION (MIN.
R20) AND TAPERED INSULATION TO
SLOPE TO ROOF DRAIN
WATERPROOFING MEMBRANE
(REFER TO NOTE AE320)
CONCRETE ROOF DECK ON
STEEL DECK
4" CONCRETE SLAB ON VAPOR
BARRIER OVER 6" MIN.
COMPACTED GRANULAR FILL
1/2" PRE-MOLDED EXPANSION
JOINT MATERIAL
2" RIGID INSULATION VERTICAL
WATERPROOFING
SURFACE APPLIED WATERSTOP
5/8" GYP. BOARD ON METAL
STUDS WITH MINERAL WOOL
BATT INSULATION - SEE WALL
TYPES SHEET
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
5/8" GYPSUM WALLBOARD ON
3-5/8" METAL STUDS @ 16" O.C.
PVC WATERSTOP; TYP.
SPRAY APPLIED INSULATION TO
UNDERSIDE OF ROOF DECK
(MIN. R-18)
FILTER FABRIC WRAPPED 6"
DIA. SLOTTED PVC IN PEA
STONE BED; REFER TO
CIVIL/ PLUMBING
WATERPROOFING
CAST STONE UNIT W/
CONTINUOUS DRIP EDGE
STANDARD BRICK VENEER ON
CMU (REFER TO STRUCTURAL)
REFER TO CIVIL
THROUGH WALL BASE FLASHING
ELEV. 826' - 6"
1ST FLOOR
D E
REGLET FLASHING, EXTEND NEW
FLASHING FROM EXISTING ROOF
MEMBRANE UP NEW EXTERIOR
WALL AS SHOWN.
CONCRETE SLAB ON STEEL
DECK
SUSPENDED ACOUSTIC PANEL
CEILING IN METAL TEE GRID
GALVANIZED STEEL; REFER
TO STRUCTURAL
STANDARD BRICK VENEER ON AIR SPACE
WITH 2" RIGID MINERAL WOOL BOARD
(MIN. R-7.5 CONTINUOUS) ON AIR/
MOISTURE BARRIER ON 5/8" EXT. GYP.
BOARD SHEATHING
HEATING SYSTEM - REFER
TO MECHANICAL
5/8" GYP. BD. ON COLD
FORMED METAL FRAMING
(FILL ENTIRE CAVITY W/ 6"
MINERAL WOOL BATT
INSULATION - MIN. R-13)
CELLULAR PLASTIC WEEP INSERTS
@ 24" O.C. IN OPEN HEAD JOINT
CAVITY DRAINAGE MATERIAL
PATCH EXISTING SUSPENDED
ACOUSTIC CEILING AS
REQUIRED, VIF
EXISTING METAL ROOF DECK,
REFER TO STRUCTURAL, VIF
MATCH DEPTH OF EXISTING
ROOF INSULATION, PATCH AND
FLASH EXISTING ROOFING AS
REQUIRED
EXPANSION JOINT W/
COMPRESSIBLE TUBE &
INSULATION & INSUL. RETAINER
STEEL STRUCTURE W/ FIBER
SPRAYED FIREPROOFING
PER UL X772 (3 HR.)
5/8" GYP. BD. & METAL STUD
FRAMING BULKHEAD
CONCRETE…