This document includes a solicitation for installation of a sterile processing supply water filtration system at a Veterans Affairs medical center. The scope of work is to demolish an existing housekeeping aids closet and install a VERDA sterile processing supply water filtration system to service the current capacity of the sterile processing supply facility in compliance with all applicable codes and standards. The project will commission the new equipment and include complete site cleanup. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The pre-bid site visit sign-in sheet is attached. No response date or award date is provided in this document.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STORAGE

450 S.F.

GB134A

HAC

GB135

STORAGE

130 S.F.

GB136

STORAGE

290 S.F.

GB137

ELECT

GA115

SOILED

HOLDING

GA116

FF:VCT FF:CONCRETE

FF:CERAMIC TILE

FF:VCT

FF:VCT

FF:CONCRETE

FF:VCT

STORAGE

300 S.F.

SEDIMENT

PALLET

SOFTENING

PALLET

EXPANSION

TANK &

BRINE

PALLET

HEATING

PALLET

9'-6"'

INSIDE

16'-4"'

INSIDE

NOTE: THE ORIGINAL FACILITY WALL LAYOUT SCALE WAS

NOT PROVIDED SO THIS SHOULD BE REFERENCE ONLY AND

NOT USED FOR SCALING. THE ROOM DOOR SHOULD BE AT

LEAST 42" TO ACCOMMODATE THE PALLET WIDTH. ALSO,

DOOR LOCATION MAY NEED TO BE CHANGED TO ALLOW

BETTER ACCESS TO INSTALL THE 72" HEATER PALLET.

4''

A

B

C

D

12345678

345678

D

C

B

A

2 1

REVISIONS

CREATED BYDATEDESCRIPTIONREV

1/2" = 1'-0"

JISHERWOOD

JISHERWOOD

D

MOUNTAIN HOME - JAMES H. QUILLEN - VAMC

VERDA LAYOUT

2023-06-05

2023-06-05

1:1 SALES --

THIS LAYOUT IS INTENDED TO BE A PRELIMINARY DESIGN FOR

GENERAL USE. MMIC RESERVES THE RIGHT TO CHANGE THE

DESIGN AT ANY TIME WITHOUT PRIOR NOTIFICATION. FINAL

DESIGNS WILL BE AGREED UPON AND DOCUMENTED WITH A

CONTRACT. ALL DIMENSIONS ARE APPROXIMATE AND ANY

PRELIMINARY SITE WORK IS AT THE PROPOSED

LEASEHOLDERS RISK.

1"LINEAR

2176 Portland Street St. Johnsbury, VT 05819 www.mmicmedical.com Phone: 1-800-748-2322 Fax: 1-802-748-2323 Email: info@mmicmedical.com

THE MATERIAL AND INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

AND IS THE PROPERTY OF MMIC AND

IS NOT TO BE USED, DISCLOSED,

COPIED, TRANSFERRED OR REPRODUCED

WITHOUT THE PRIOR WRITTEN

PERMISSION OF MMIC.

DO NOT SCALE

ALL DIMENSIONS ARE

IN INCHES

TOLERANCES

UNLESS OTHERWISE SPECIFIED

1ANGULAR

DETAILER:

DESIGNER:

SIZE DWG NO.SHEET NO.

TITLE:

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REV.