S05 - Amendment 0004 - Attachment 3 - Memphis LS Building 1A Second Floor.pdf
PDF 434 KB Posted
- Solicitation number
- 36C24922R0058
About this file
This document includes a federal contract opportunity notice and related facility floor plan documents. The contract opportunity is a two-phase design-build project to install miscellaneous high-technology, high-cost equipment in a cardiac cath lab at the Memphis VA Medical Center in Memphis, Tennessee. The project scope includes general construction, alterations, mechanical and electrical work, and utility systems to renovate approximately 1,560 square feet of second floor space in Building 1A. The project magnitude is estimated between $1,000,000 to $2,000,000 and work must be completed within 210 calendar days. The procurement is set aside 100% for service-disabled veteran-owned small businesses. The solicitation and amendments will be available on or about May 16, 2022 via www.sam.gov in PDF format. Offerors must ensure they can provide both 100% performance and payment bonds and submit a bid guarantee with proposals. The VA will evaluate proposals and make award using best value per FAR Part 15, with no discussions anticipated.
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN UP
UPDN
DN
COURTYARD
ROOF
DN
UP
FENCE
GATE
ELECTRICAL
G224A
FORMS
STG
CHART
C2-3B
CORRIDOR
C2-3
SCRUB
G225
CORRIDOR
C2-20
CORRIDOR
C2-16
CORRIDOR
C2-18
CORRIDOR
C2-17
CORRIDOR
C2-19
CORRIDOR
C2-21
CORRIDOR
C2-25
CORRIDOR
C2-23
CATH
LAB
G224
CORRIDOR
G225A
CONT/DATA
G221B
CATH
LAB
G221
SU
G221C
ELECTRICAL
G221A
FILM
VIEW
STG
G225B
HAC
G235
STAFF
TOILET
G227
S U G226
TOILET
G225E
LOCKER
G225F
LOCKER
G225C
TOILET
G225D
STRESS
LAB
G231
STUDY
G229
ELECTRICAL
G233
CONF
G230
RES OFF
STUDY
G228
OFFICE
G210
SPUTUM
G204
SPUTUM
G203
PATIENT
TOILET
G202
COMM
G234
PATIENT
FILE
G201
PATIENT
FILE
G205A
REPORT
G205
BREAK RM
G200
LOUNGE
G206
CORRIDOR
C2-24
SEC
G207A
SUPERVISORS
G209
STG
G208
CHIEF
G207
CLEAN
SUPPLY
G212
STOR
G211
SUPPLIES
G211A
CONTROL
C2-19A
CONTROL
C2-20A
MICU
C2-16A
CLEAN UTILITY
F215
ON CALL
F214S U
F213
ON CALL
F211
STRETCH/
WHEELCHR
C2-17A
BATH
F211A
PORT
X-RAY
C2-17B
OFFICE
F208
SAT
PHARM
F200
PRACTICE RM
F240
CICU
PATIENT
RM
F239
CICU
PATIENT
RM
F238
CICU
PATIENT
RM
F237
CICU
PATIENT
RM
F236
CICU
PATIENT
RM
F234
BREAK
F231
COMP
EQUIP
F224
MED
F220
LOCKER
F231A
STAFF
TOILET
F231B
STAFF
TOILET
F232
BLOOD
GAS
G217
SPEC
PROC
BRONCH
G216
VIEWING
G216A
S U G215A
STRETCH
C2-21A
BRONCHOSCOPY
G215
SPIRO
G213
SPIRO
G214
NOURISHMENT
F216A
CLEAN
UTILITY
F216
EQUIP
F233
CLEAN
LINEN
F235
STERILE
PREP
F200A
FAMILY
CONSULT
F201
OFFICE
F206
CONSULT
F202
HAC
F203
PHYS
OFFICE
F204
PHYS
OFFICE
F205
ANTE
F209
MICU
PATIENT
RM
F210
MICU
PATIENT
RM
F212
MICU
PATIENT
RM
F217
MICU
PATIENT
RM
F218
MICU
PATIENT
RM
F219
MICU
PATIENT
RM
F221
C2-22A
C U G222
OFFICE
G223
ELECTRICAL
G219
NUR/
TECH
OFFICE
G220
MECH
G218
STAIR
ANTE
F229
CLASS/CONFERENCE RM
F230
MICU
PATIENT
RM
F228
MICU
PATIENT
RM
F227
MICU
PATIENT
RM
F226
MICU
PATIENT
RM
F225
MICU
PATIENT
RM
F223
MICU
PATIENT
RM
F222
C0RRIDOR
C2-12A
NOUR
E209MED
E225
CORRIDOR
C2-14
CORRIDOR
C2-10B
C0RRIDOR
C2-13
CORRIDOR
C2-9
C0RRIDOR
C2-10
ALCOVE
C2-13A
CORRIDOR
C2-11
CORRIDOR
C2-2
CORRIDOR
C2-8
CORRIDOR
C2-6
SVC
ELEVATOR
LOBBY
C2-5
CORRIDOR
C2-1
WAITING
C2-1C
CORRIDOR
C2-4
CORRIDOR
C2-15
CRIT CARE
WAITING
C2-1D
PASS ELEVATOR
LOBBY
C2-1A
TRASH
CHUTE
D224
TOILET
D231
C2-1B
WOMENS
TOILET
D232
ELEVATOR
NO P2
ELEVATOR
NO P1
ELEVATOR
NO P4
ELEVATOR
NO P3
HAC
D226
LINEN
CHUTE
D225
NURSE/TECH
WORK
D208
DW
D223
VIEW /
READ
D206
DW
NO 1
C2-12
NURSE
STATION
C2-10C
ELEVATOR
NO S7
HAC
D204
ELEVATOR
NO S6
ELEVATOR
NO S5
STAIR
NO 14
D221
CARDIO/PULMONARY REHAB
D228
TOILET/SHOWER
D228A TOILET FILE STORAGE
D227
BIOMED
D216
PRINTER
D222 EXAM
D219
EXAM
D220
EXAM
D218
EXAM
D217
SUPPLY
D215
CHART
C2-3A
EXAM
D214
EXAM
D212
EXAM
D213
EXAM
D211
LAB
D209
EXAM
D210
PACEMAKER
D207
ECG
D205
ECHO
D203
ECHO
D201
CARDIOLOGY
CARDIOLOGY
LIPID CLINIC
RECEPTION
C2-6A
WAITING
C2-6B
PATIENT
TOILET
D202
TOILET
D200
G232
CLERICAL/
TECH
SUPV
D230A
REHAB
OFFICESTORE
E214
BATH
E213B
ANTE
E213
ISO
E213A
CRASH
C2-10A
WORK RM
E210
ELECTRICAL
E211
ANTE
E212
BATH
E212B
ISO
E212A
DICT
E210A
BATH
E208A
PATIENT
E208
BATH
E204A
PATIENT
E206
BATH
E203A
PATIENT
E204
OFFICE
E203
MONITOR RM
E200
ALCOVE
C2-13B
LOUNGE/
LKRS
E205
CLEAN LINEN
E207
CU
E227
EXAM
E202
PHYS
CONS
E201
COMM
E236
SU
E229
TOILET
E231
HAC
E233
ELECTRICAL
E235
STAIR
NO 16
BATH
E232A
BATH
E228A
STORAGE
E234
PATIENT
E232
PATIENT
E230
PATIENT
E228
BATH
E224A
PATIENT
E226
PATIENT
E224
MECH
D229
STAIR
NO15
BATH
E215A
PATIENT
E215
PATIENT
E216
BATH
E217A
PATIENT
E217
PATIENT
E218
BATH
E219A
PATIENT
E219
PATIENT
E220
HEAD
E221
DAY RM
E222
E223
CORRIDOR
C2-7
CORRIDOR
C2-22
SHAFT
OPEN
ICU
IC
U
W
AR
D 2 S
WARD 2 S
CATH LAB
STRESS
LAB
CO2
SHAFT
MIST
EXAM
CO2
COURTYARD
OPEN
COURTYARD
OPEN
CA
TH
LA
B
HE
ZONE 1A - 2 - 3
ZONE 1A - 2 - 2
BUILDING 1A BUILDING 1
ZONE 1A - 2 - 1 ZONE 1A - 2 - 2
HE
ZONE 1A - 2 - 4
ZONE 1A - 2 - 1
ZONE 1A - 2 - 4 ZONE 1A - 2 - 3
BUILDING 1A
SECOND FLOOR
FULLY SPRINKLERED
HEALTH CARE OCCUPANCY
N
Office of Construction and Facilities Management
Project NumberProject Title
Location
Date Checked Drawn
Drawing Number
Dwg. of
Approved: Project Director
Drawing TitleENGINEERS
DateRevisions
Building Number
SITE NAME/ADDRESS
NUMBER
DRAFT - LS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FP&C Project Number 3135.00
REVISED DRAFT - LS
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
FIRE EXTINGUISHER
EXIT SIGN
EMERGENCY LIGHT
FIRE ALARM STATION
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
AUTOMATED EXTERNAL DEFIBRILLATOR
EYEWASH STATION
SPRINKLER SYSTEM RISER
SHOWER STATION
EVACUATION CHAIR
HE
EX
EP
TC
FIRE HOSE VALVE
LC
PARTITION LEGEND
2 HOUR FIRE BARRIER
3 HOUR FIRE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
10/30/18 10/28/18
FINAL - LS 02/22/19 MEMPHIS, TN
MEMPHIS VAMC
LIFE SAFETY
DOCUMENTATION
TKFVO05/29/2019
FINAL - VA COMMENTS 05/29/19
2 HOUR FIRE/SMOKE ZONE BARRIER
BUILDING 1A
FIRST FLOOR
LS 1A - 2
10 20
1A
V09-18-101