This letter report summarizes the results of a limited lead paint sampling event conducted at the Lexington VA Medical Center in Lexington, Kentucky. Terracon Consultants collected paint chip samples from six prominent painted surfaces within the renovation project space on the first floor for the planned new mental health unit. Laboratory analysis found one sample contained lead above the detection limit. The report notes applicable OSHA regulations for lead exposure and that contractors bidding on or conducting work disturbing painted surfaces should plan for compliance. It provides the sample summary table and laboratory analytical report as attachments.
The related federal contract opportunity is a solicitation for construction services to renovate space for the new mental health unit at the Lexington VA Medical Center, with solicitation number 36C24920R0075. The opportunity type is listed as a solicitation from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. No further details are provided on response dates, award dates, pricing terms, or set asides.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Terracon Consul tants, Inc. 611 Lunken Park Dr ive Cincinnat i , OH 45226-1813 P (513) 321-5816 F (513) 321-0294 terracon.com
E n v i r o n m e n t a l F a c i l i t i e s G e o t e c h n i c a l M a t e r i a l s
May 9, 2019
FFE, Inc.
438 Springfield Pike, Suite C Cincinnati, Ohio 45215
Attn: Mr. Clint Weekley, PE, CBCP, LEED AP President T: (513) 522-0956 E: clint.weekley@ffe-serv.com
Re: Lead Paint Consulting Services VA Project: Renovate Space for New Mental Health Unit VA Project No. 596A4-18-107 Department of Veterans Affairs Medical Center Cooper Division 1101 Veterans Drive Lexington, KY 40502-2236 Terracon Project No. PN1187353
Dear Mr. Weekley:
Terracon Consultants, Inc. (Terracon) appreciates the opportunity to submit this letter report to FEE, Inc. (Client) regarding the lead analytical results for limited paint samples collected for the above-referenced project at the Lexington VA Medical Center (VAMC) - Cooper Division.
This project pertains to a planned renovation regarding a specific area on the North side of the first floor at the Lexington VAMC (approximately 12,500 square feet total).
Terracon representatives Mr. Joshua Vogel and Mr. Lemuel Weyer collected paint samples from various prominent painted surfaces within the renovation space. Samples were collected using a clean straight-edge razor to remove paint from designated surfaces. Collected material was placed in a sealable container, labeled with a unique sample number, and submitted under chain of custody to International Asbestos Testing Laboratories (IATL) of Mount Laurel, New Jersey.
Paint chip samples were analyzed by Atomic Absorption Spectroscopy (AAS) per EPA Method SW846/3050B/7420M. IATL is accredited for lead in paint analysis by the American Industrial Hygiene Association’s (AIHA®) Environmental Lead Laboratory Accreditation Program (ELLAP), accreditation number 100188.
Limited Paint Sampling for Lead-Content Analysis 1th Floor New Mental Acute Inpatient Unit ■ Lexington VAMC - Cooper Division May 9, 2019 ■ Terracon Project No. N1187353
Responsive ■ Resourceful ■ Reliable 2
Lead Paint Analytical Results Summary
Terracon collected a total of six paint samples for lead-content analysis from within the renovation project spaces. A sample summary which includes sample descriptions and analytical results are attached; results are presented in parts per million (ppm) lead. Of the six (6) samples collected, one (1) sample was identified by laboratory analysis to contain lead above the detection limit. The laboratory analytical report and sample chain of custody are also attached.
Occupational Safety and Health Administration (OSHA) standard, 29 Code of Federal Regulations (CFR) 1926.62 (Lead in Construction), does not reference a specific concentration of lead in a surface coating. The requirements under OSHA 29 CFR 1926.62 are applicable to any concentration of lead found above analytical limit of detection (LOD). When disturbed, paints containing lead in any concentration may present an airborne exposure hazard that could exceed the OSHA legally enforceable action level (AL) or permissible exposure limit (PEL). Contractors that bid or conduct work activities that will disturb surfaces with analytically-confirmed LCP should be made aware so that they can plan for proper compliance with applicable federal and state regulations, and any applicable Client specifications. Additionally, contractors should understand that any untested paint surfaces are assumed to contain lead unless sampling and analysis refute lead-content.
This sampling event was conducted as per the direction and request of the Client. The sampling was of a limited nature specific to prominent and readily accessible painted surfaces and may not have included every painted surface. The sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings and recommendations expressed in this letter report are based on conditions observed during the sampling event. This letter report has been prepared on behalf of and exclusively for use and reliance by the Client and is not a bidding document. Contractors or consultants reviewing this limited sampling report must draw their own conclusions regarding whether further investigation or remediation is deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third-parties supplying information, which may have been used in the preparation of this report. No warranty, express or implied, is made.
May 9, 2019 ■ Terracon Project No. N1187353
Responsive ■ Resourceful ■ Reliable 3
Terracon appreciates the opportunity to provide this service to FFE, Inc. If you have questions regarding this letter report or if we can be of further service, please contact the under-signed at (513) 321-5816.
Sincerely, Terracon Consultants, Inc.
For:
Lemuel Weyer Micheal S. Crandall,CIH Environmental Technician Industrial Hygienist
Attachments: Sample Summary Table Laboratory Analytical Report jatussey Stamp
May 9, 2019 ■ Terracon Project No. N1187353
Responsive ■ Resourceful ■ Reliable 4
Attachment 1: Sample Summary Table
May 9, 2019 ■ Terracon Project No. N1187353
Responsive ■ Resourceful ■ Reliable 5
Terracon Sample # Component Paint
Color (surface) Substrate Sample Location
Comments / Results
L-1 Wall White Drywall A114- Northeast Corner <94 ppm
L-2 Wall Blue Drywall New Entry to A114 <77 ppm
L-3 Wall Brown Drywall Hallway near A133 <60 ppm
L-4 Door Brown Metal A135 <65 ppm
L-5 Door Frame Brown Metal A133a 160 ppm
L-6 Wall Gray Drywall Northeast
Corner of Main Lobby
<67 ppm
< = less than limit of detection (LOD)
May 9, 2019 ■ Terracon Project No. N1187353
Responsive ■ Resourceful ■ Reliable 6
Attachment 2: Laboratory Analytical Report
Lab No.: 6762638 Client No.: L-1
Description: White Drywall Paint Location: A114 Northeast Corner-Wall
Result (% by Weight): <0.0094 Result (ppm): <94 Comments:
Lab No.: 6762639 Client No.: L-2
Description: Blue Drywall Paint Location: New Entry To A114-Wall
Result (% by Weight): <0.0077 Result (ppm): <77 Comments:
Lab No.: 6762640 Client No.: L-3
Description: Brown Drywall Paint Location: Hallway Near A133-Wall
Result (% by Weight): <0.0060 Result (ppm): <60 Comments:
Lab No.: 6762641 Client No.: L-4
Description: Brown Metal Paint Location: A135-Door
Result (% by Weight): <0.0065 Result (ppm): <65 Comments:
Lab No.: 6762642 Client No.: L-5
Description: Brown Metal Paint Location: A133a-Door Frame
Result (% by Weight): 0.016 Result (ppm): 160 Comments:
Lab No.: 6762643 Client No.: L-6
Description: Grey Drywall Paint Location: Northeast Corner Of Main Lobby-Wall
Result (% by Weight): <0.0067 Result (ppm): <67 Comments:
Laboratory Director
Approved By:
Date Analyzed:
4/12/2019Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Chad Shaffer
04/18/2019 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
4/18/2019Report Date:
Report No.: 587680 - Lead Paint Project: Lexington VAMC Project No.: N1187353
LEAD PAINT SAMPLE ANALYSIS SUMMARY
Client: TER940
Dated : 4/18/2019 3:52:17 Page 1 of 2
Appendix to Analytical Report:
Customer Contact:
Method: ASTM D3335-85a, US EPA SW846 3050B:7000B
This appendix seeks to promote greater understanding of any observations, exceptions, special instructions, or circumstances that the laboratory needs to communicate to the client concerning the above samples. The information below is used to help promote your ability to make the most informed decisions for you and your customers.
Please note the following points of contact for any questions you may have.
iATL Customer Service: customerservice@iatl.com iATL Office Manager:wchampion@iatl.com iATL Account Representative: Cassie Doherty Sample Login Notes: See Batch Sheet Attached Sample Matrix: Paint Exceptions Noted: See Following Pages
General Terms, Warrants, Limits, Qualifiers:
General information about iATL capabilities and client/laboratory relationships and responsibilities are spelled out in iATL policies that are listed at www.iATL.com and in our Quality Assurance Manual per ISO 17025 standard requirements. The information therein is a representation of iATL definitions and policies for turnaround times, sample submittal, collection media, blank definitions, quantification issues and limit of detection, analytical methods and procedures, sub-contracting policies, results reporting options, fees, terms, and discounts, confidentiality, sample archival and disposal, and data interpretation.
iATL warrants the test results to be of a precision normal for the type and methodology employed for each sample submitted. iATL disclaims any other warrants, expressed or implied, including warranty of fitness for a particular purpose and warranty of merchantability. iATL accepts no legal responsibility for the purpose for which the client uses test results. Any analytical work performed must be governed by our Standard Terms and Conditions. Prices, methods and detection limits may be changed without notification. Please contact your Customer Service Representative for the most current information.
This confidential report relates only to those item(s) tested and does not represent an endorsement by NIST-NVLAP, AIHA LAP LLC, or any agency of local, state or province governments nor of any agency of the U.S. government.
This report shall not be reproduced except in full, without written approval of the laboratory.
Information Pertinent to this Report:
Analysis by ASTM D3335-85a by AAS
Certification:
- National Lead Laboratory Program (NLLAP): AIHA-LAP, LLC No. 100188
- NYSDOH-ELAP No. 11021
Regulatory limit is 0.5% lead by weight (EPA/HUD guidelines). Recommend multiple sampling for all samples less than regulatory limit for confirmation.
All results are based on the samples as received at the lab. iATL assumes that appropriate sampling methods have been used and that the data upon which these results are based have been accurately supplied by the client.
Method Detection Limit (MDL) per EPA Method 40CFR Part 136 Apendix B.
Reporting Limit (RL) based upon Lowest Standard Determined (LSD) in accordance with AIHA-ELLAP policies.
LSD=0.2 ppm MDL=0.005% by weight. RL= 0.010% by weight (based upon 100 mg sampled).
Disclaimers / Qualifiers:
There may be some samples in this project that have a "NOTE:" associated with a sample result. We use added disclaimers or qualifiers to inform the client about something that requires further explanation. Here is a complete list with highlighted disclaimers pertinent to this project. For a full explanation of these and other disclaimers, please inquire at customerservice@iatl.com.
* Insufficient sample provided to perform QC reanalysis (<200 mg) ** Not enough sample provided to analyze (<50 mg) *** Matrix / substrate interference possible.
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon 611 Lunken Park Drive Cincinnati OH 45226
4/18/2019Report Date:
Report No.: 587680 - Lead Paint Project: Lexington VAMC Project No.: N1187353
Client: TER940