36C24919R0128-003.pdf
PDF 18 MB Posted
- Solicitation number
- 36C24919R0128
About this file
36C24919R0128 Drawings - 626-308.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24919R0128-0004001.pdf | ||
| 36C24919R0128-0004000.docx | DOCX document | |
| 36C24919R0128-0003004.pdf | ||
| 36C24919R0128-0003005.pdf | ||
| 36C24919R0128-0003000.docx | DOCX document | |
| 36C24919R0128-0003008.pdf | ||
| 36C24919R0128-0003001.pdf | ||
| 36C24919R0128-0003006.pdf | ||
| 36C24919R0128-0003003.pdf | ||
| 36C24919R0128-0003007.pdf | ||
| 36C24919R0128-0003002.pdf | ||
| 36C24919R0128-0003009.pdf | ||
| 36C24919R0128-0002000.docx | DOCX document | |
| 36C24919R0128-0001005.pdf | ||
| 36C24919R0128-0001002.pdf | ||
| 36C24919R0128-0001008.pdf | ||
| 36C24919R0128-0001000.docx | DOCX document | |
| 36C24919R0128-0001006.pdf | ||
| 36C24919R0128-0001004.pdf | ||
| 36C24919R0128-0001007.pdf | ||
| 36C24919R0128-0001003.pdf | ||
| 36C24919R0128-0001001.pdf | ||
| 36C24919R0128-000.docx | DOCX document | |
| 36C24919R0128-005.xlsx | XLSX spreadsheet | |
| 36C24919R0128-002.pdf | ||
| 36C24919R0128-001.docx | DOCX document | |
| 36C24919R0128-004.docx | DOCX document |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
12'-2"
11'-3"
9'-3"
11'-5" 8'
VETERANS BLVD
VETERANS CIRCLE
VETERANS CIRCLE
VETERANS CIRCLE
VETERANS CIRCLE
EAST MAIN STREET
E A
S T
V
IE
W D
R
IV
E
JOHN F COADY DRIVE
LAKE ROAD
L P T A N K
P ro p a n e
L in e
A p p ro x B e lo w
G ra d e
P ro p a n e
L in e
A p p ro x B e lo w
G ra d e
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
LAR
E GI H,NC
N
ED
M RU
P
Y
RE
G
IS
TER
ED ARCHITECT
N O R
T H CA RO
L
I N A
NY
H
M
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:2
:1
P
M
G-001
COVER
1 4DMM EGS
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON RD, MURFREESBORO,
TN 37129
04/01/2019
BID DOCUMENTS
626-30818-262
USP 800 PHARMACY COMPLIANCE FOR
YORK VAMC - TVHS
3400 LEBANON RD, MURFREESBORO, TN 37129
VA PROJECT #: 626-308 APOGEE PROJECT #: 18-262
PROJECT LOCATION PHARMACY SITE
Scale: 1" = 160'-0"
CAMPUS MAP
Scale: No Scale
PROJECT LOCATION MAP
DocuSign Envelope ID: 6C0D5F5C-7BF4-41CC-847B-538B2840634D
3/29/2019
WALL SECTION
SYMBOL
INTERIOR ELEVATION
SYMBOL
COLUMN GRID
ELEVATION SYMBOL
REVISION NOTE
ENLARGED DETAIL CALLOUT
ROOM DESIGNATION
SYMBOL
BREAK LINE
ROOF SLOPE
DIRECTION SYMBOL
TYPICAL GRAPHIC SCALE
DETAIL #
PAGE #
DETAIL #
PAGE #
TRUE NORTH ARROW
PROJECT NORTH ARROW
A8.1
EXTERIOR ELEVATION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
A8.1
BUILDING SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
WALL GRID
(REPRESENTS
FACE OF EXISTING
WALL)
XX.X
XX.X
ELEVATION
0'-0"
ROOM
NAME
101A
NORTH
PLAN
NORTH
TRUE
0 4 8 16
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
LAR
E GI H,NC
N
ED
M RU
P
Y
RE
G
IS
TER
ED ARCHITECT
N O R
T H CA RO
L
I N A
NY
H
M
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:2
:1
P
M
G-100
GENERAL INFORMATION
2 4DMM HM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON RD, MURFREESBORO,
TN 37129
04/01/2019
BID DOCUMENTS
626-30818-262
DRAWING LIST
No. Description Dwg of Dwg
GENERAL
G-001 COVER 1 4
G-100 GENERAL INFORMATION 2 4
G-101 INFECTION CONTROL RISK ASSESSMENT (ICRA) 3 4
LS101 GROUND FLOOR LIFE SAFETY 4 4
CIVIL
C-1 DEMOLITION PLAN 1 3
C-2 SITE & GRADING PLAN 2 3
C-3 CONSTRUCTION DETAILS 3 3
STRUCTURAL
S-101 GROUND FLOOR PLAN 1 6
S-102 FIRST FLOOR - EQUIPMENT PLAN 2 6
S-103 ROOF FRAMING PLAN 3 6
S-301 FOUNDATION DETAILS 4 6
S-501 FRAMING DETAILS 5 6
S-502 LATERAL FRAMING DETAILS 6 6
ARCHITECTURAL
A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 20
AD101 GROUND FLOOR & ROOF DEMOLITION PLAN 2 20
A-100 SITE PLAN 3 20
A-101 GROUND FLOOR PLAN 4 20
A-102 EQUIPMENT PLATFORM PLAN 5 20
A-103 ROOF PLAN 6 20
A-110 GROUND FLOOR REFLECTED CEILING PLAN 7 20
A-111 EQUIPMENT PLATFORM REFLECTED CEILING PLAN 8 20
A-201 EXTERIOR ELEVATIONS 9 20
A-301 BUILDING SECTIONS 10 20
A-302 WALL SECTIONS 11 20
A-303 WALL SECTIONS 12 20
A-304 WALL SECTIONS AND DETAILS 13 20
A-401 INTERIOR ELEVATIONS 14 20
A-402 INTERIOR ELEVATIONS 15 20
A-501 PARTITION TYPES 16 20
A-601 ROOM FINISH AND DOOR SCHEDULES 17 20
A-700 MODULAR CLEAN ROOM DETAILS 18 20
A-701 PLAN DETAILS 19 20
A-800 EQUIPMENT PLAN 20 20
FIRE PROTECTION
FX001 FIRE PROTECTION GENERAL INFORMATION 1 2
FX101 GROUND FLOOR FIRE PROTECTION PLAN 2 2
PLUMBING
P-001 PLUMBING GENERAL INFORMATION 1 3
PP101 GROUND FLOOR DOMESTIC WATER PLAN 2 3
PW101 UNDERSLAB FLOOR DRAIN, WASTE, AND VENT PLAN 3 3
MECHANICAL
M-001 MECHANICAL GENERAL INFORMATION 1 12
MH101 GROUND FLOOR HVAC PLAN 2 12
MH102 AIR TERMINAL PLAN 3 12
MP101 GROUND FLOOR MECHANICAL PIPING PLAN 4 12
MP102 BASEMENT MECHANICAL PIPING PLAN 5 12
M-501 MECHANICAL DETAILS 6 12
M-502 MECHANICAL DETAILS 7 12
M-503 MECHANICAL CONTROLS 8 12
M-504 MECHANICAL CONTROLS 9 12
M-601 MECHANICAL SCHEDULES 10 12
M-602 MECHANICAL SCHEDULES 11 12
M-901 ISOMETRIC VIEWS 12 12
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 10
EP101 BASEMENT FLOOR POWER PLAN 2 10
EP102 GROUND FLOOR POWER PLAN 3 10
EP103 FIRST FLOOR POWER PLAN 4 10
EP104 LIGHTNING PROTECTION PLAN 5 10
EL101 GROUND FLOOR LIGHTING PLAN 6 10
EL102 FIRST FLOOR LIGHTING PLAN 7 10
E-501 ELECTRICAL DETAILS 8 10
E-601 ONE-LINE DIAGRAM 9 10
E-602 ELECTRICAL SCHEDULES 10 10
TECHNOLOGY
TK001 TECHNOLOGY GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS 1 3
TK101 GROUND FLOOR TECHNOLOGY & SECURITY PLAN 2 3
TK501 TECHNOLOGY DETAILS 3 3
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES, SYMBOLE LEGEND, AND RISER 1 2
FA101 GROUND FLOOR FIRE ALARM PLAN 2 2
GENERAL SYMBOL LEGEND
SITE NOTES
1. WORKING SPACE AND SPACE AVAILABLE FOR STORING MATERIALS SHALL BE AS
DETERMINED BY THE COR
2. KEEP ROADS CLEAR OF CONSTRUCTION MATERIAL, DEBRIS, STANDING CONSTRUCTION
EQUIPMENT AND VEHICLES AT ALL TIMES. DO NOT STORE MATERIALS AND EQUIPMENT
IN OTHER THAN ASSIGNED AREAS.
3. SCHEDULE DELIVERY OF MATERIALS AND EQUIPMENT TO IMMEDIATE CONSTRUCTION
WORKING AREAS IN QUANTITIES SUFFICIENT FOR NOT MORE THAN TWO WORK DAYS.
PROVIDE UNOBSTRUCTED ACCESS TO MEDICAL CENTER AREAS REQUIRED TO REMAIN
IN OPERATION.
4. COORDINATE WITH COR FOR REMOVAL OF EXISTING FURNISHINGS AND EQUIPMENT TO
PERMIT WORK TO PROCEED. CONTRACTOR SHALL PROVIDE THE COR WITH A COPY OF
THEIR LOTO PROCEDURE WITHIN TEN DAYS OF RECEIVING THE NTP.
5. COORDINATE THE WORK FOR THIS CONTRACT WITH OTHER CONSTRUCTION
OPERATIONS AS DIRECTED BY COR. THIS INCLUDES THE SCHEDULING OF TRAFFIC AND
THE USE OF ROADWAYS, AS SPECIFIED IN ARTICLE, USE OF ROADWAYS.
6. UTILITIES SERVICES: MAINTAIN EXISTING UTILITY SERVICES FOR MEDICAL CENTER AT
ALL TIMES. PROVIDE TEMPORARY FACILITIES, LABOR, MATERIALS, EQUIPMENT,
CONNECTIONS, AND UTILITIES TO ASSURE UNINTERRUPTED SERVICES AS REQUIRED BY
THE DRAWINGS AND SPECIFICATIONS. WHERE NECESSARY TO CUT EXISTING WATER,
STEAM, GASES, SEWER OR AIR PIPES, OR CONDUITS, WIRES, CABLES, ETC. OF UTILITY
SERVICES OR OF FIRE PROTECTION SYSTEMS AND COMMUNICATIONS SYSTEMS
(INCLUDING TELEPHONE), THEY SHALL BE CUT AND CAPPED AT SUITABLE PLACES
WHERE SHOWN; OR, IN ABSENCE OF SUCH INDICATION, WHERE DIRECTED BY COR.
7. OBTAIN ASBESTOS ABATEMENT PLANS FROM VA COR PRIOR TO START OF WORK.
COMPLETE WORK FOR ASBESTOS ABATEMENT PRIOR TO THE START OF
CONSTRUCTION OR DEMOLITION. REFER TO SPECIFICATIONS FOR REQUIREMENTS FOR
ASBESTOS ABATEMENT.
GENERAL NOTES
1. REFER TO PLUMBING, ELECTRICAL, AND MECHANICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
2. PROVIDE BLOCKING AT PARTITIONS AS REQUIRED FOR MOUNTING OF WALL-
MOUNTED ITEMS: PROVIDE SUPPLEMENTAL FRAMING AT WALL OPENINGS
INCLUDING KING STUDS, JACK STUDS, AND CRIPPLE STUDS, AS REQUIRED FOR
COMPLETION OF THE WORK.
3. COORDINATE THE WORK OF TRADES PRIOR TO THE START OF CONSTRUCTION.
4. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK FOR EACH
PHASE.
5. NOTIFY THE COR OF DISCREPANCIES IN THE DRAWINGS AND SPECS PRIOR TO THE
START OF WORK.
6. DIMENSIONS SHOWN ARE TO FACE OF STUD FRAMING, FACE OF
CONCRETE/MASONRY WALLS, OR FINISHED FACE OF EXISTING WALL SURFACE.
7. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
8. INSTALL ALL WORK IN ACCORDANCE WITH CURRENT APPLICABLE CODES AND
PUBLISHED STANDARDS.
9. INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN FOR
GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF THE
DESIGNER AS TO THE LIMITATIONS OF THE WORK AREA IN AN OCCUPIED AREA.
ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY AGREEMENT BETWEEN THE
COR AND CONTRACTOR BEFORE THE START OF THE WORK.
10. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR
CONVENIENCE. THE SEPARATIONS USED ARE USED ONLY FOR THE PURPOSES OF
CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT THE
SCOPE OR INTENT OF ANY PART OF THE DRAWINGS, OR OF THE DRAWINGS AND
SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE SEPARATED IN
NO WAY SUGGESTS THAT THE WORK IS NOT TO BE CONSTRUCTED AS A COMPLETE,
INTEGRATED AND UNIFIED WHOLE.
11. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY
SPECIFIC ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN IN ANY
ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF
THE CONTRACT FOR CONSTRUCTION.
12. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR
REFERENCE ONLY AND ARE NOT INTENDED TO ACCURATELY DEPICT ACTUAL OR
DESIGNATED CONDITIONS. WRITTEN DIMENSIONS SHALL GOVERN.
13. AT AREAS INDICATED TO BE PATCHED AND REPAIRED, THE CONSTRUCTION AND
ASSEMBLY OF THE PATCH OR REPAIR SHALL MATCH THE ASSEMBLY AND INTEGRITY
OF THE ADJACENT EXISTING CONSTRUCTION, FOR FIRE RATING, MATERIALS, FINISH,
THICKNESS, AND QUALITY.
DEMOLITION NOTES
1. KEY NOTES AND DRAWINGS ARE INTENDED TO GRAPHICALLY REPRESENT
GENERAL WORK AND DO NOT PORTRAY FULL SCOPE OF THE PROJECT. SEE
SPECIFICATIONS FOR DETAILED REQUIREMENTS.
2. REMOVE EXISTING CONSTRUCTION AS INDICATED AND CLEAR AREA OF DEBRIS
PRIOR TO PROCEEDING WITH NEW CONSTRUCTION.
3. EQUIPMENT REMOVED SHALL BE LEGALLY DISPOSED OFF MEDICAL CENTER
GROUNDS.
4. COORDINATE WITH VA COR FOR DEMOLITION SCHEDULE AND SCHEDULE OF
WASTE REMOVAL.
5. NOTIFY COR OF DEMOLITION REQUIRED AND NOT INDICATED FOR INSTALLATION OF
ELECTRICAL OR DATA ITEMS. AFTER SUCH DEMOLITION AND INSTALLATION, PATCH
OR REPLACE MATERIALS AND FINISHES TO MATCH EXISTING.
6. THE INFORMATION CONTAINED IN THESE DEMOLITION DOCUMENTS DOES NOT
RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF PROVIDING ALL
DEMOLITION REQUIRED FOR THE COMPLETION OF THE PROJECT.
7. REFER TO THE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION REGARDING
DEMOLITION OF ELECTRICAL SYSTEMS.
8. BEFORE THE START OF WORK, IDENTIFY ANY REQUIRED DEMOLITION BEYOND THE
IDENTIFIED PROJECT SCOPE WHETHER ABOVE, BELOW OR OUTSIDE PROJECT
AREA. NOTIFY AND COORDINATE WITH THE COR, PROVIDE DEMOLITION OF THESE
AREAS AND PATCH THE SAME AS A PART OF THE SCOPE OF THE PROJECT.
9. ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND DILIGENCE IN
ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE OR
CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE. DISCOVERY OF UTILITIES
OR CONDITIONS LOCATED DIFFERENTLY FROM THAT INDICATED OR THAT ARE NOT
IDENTIFIED. SHALL BE REPORTED TO THE CONTRACTING OFFICER (COR).
10. COORDINATE WITH VA COR FOR CONSTRUCTION ACCESS ROUTE AND LOCATIONS
OF DUMPSTER AREA. COORDINATE WITH COR FOR SCHEDULE OF USE OF ACCESS
ROUTE FOR WASTE REMOVAL AND CONTRACTOR USE OF FREIGHT ELEVATOR.
3 5/8" INSULATED WALL WITH
16 GAUGE METAL STUDS @
16" O.C. WALL TO EXTEND TO
UNDERSIDE OF DECK
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
EXISTING CEILING SYSTEM
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING
DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
W A
L L
H E
IG
H
T V
A R
IE
S
F
IE
L D
V E
R
IF
Y
5"
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
EXISTING CEILING SYSTEM
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING
DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
/2
5"
3 5/8" 16 GAUGE METAL
STUDS @ 16" O.C. WALL TO
EXTEND TO UNDERSIDE OF
DECK
A B
3 5/8" INSULATED WALL WITH
16 GAUGE METAL STUDS @
16" O.C. (2) LAYERS 5/8"
GYPSUM BOARD EACH SIDE.
WALL TO EXTEND TO
UNDERSIDE OF DECK
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
EXISTING CEILING SYSTEM
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING
DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
W A
L L
H E
IG
H
T V
A R
IE
S
F
IE
L D
V E
R
IF
Y
6"
C
FIRE RESISTANT SEALANT,
BOTH SIDES
FIRE RESISTANT SEALANT,
BOTH SIDES
FIRE RESISTANT SEALANT,
BOTH SIDES
1-HR RATED AND SMOKE RATED
U.L. DESIGN NO. U404
SMOKE RATED 2-HR RATED AND SMOKE RATED
U.L. DESIGN NO. U404
HEPA
NEGATIVE AIR
UNIT
FINISHED FLOORING TO BE KEPT
CLEAN. FLOORS NOT BEING REPLACED
MUST BE PROTECTED. COVER WITH
ROSIN PAPER / FIRE RATED PLYWOOD.
FIRE RATED PLYWOOD,
TEMPORARY. SALVAGE
PROTECT AND STORE
EXISTING WINDOW TO
BE RE-INSTALLED
AFTER CONSTRUCTION
IS COMPLETE.
V .I
.F
V .I
.F
V.I.F.
V .I .F
E X
IS
T
IN
G
W A
L L
V .I .F
E X
IS
T
IN
G
W A
L L
FIRE EXTINGUISHER ON
PORTABLE FLOOR
BRACKET (ILSM MAY
REQUIRE MORE THAN
ONE).
PROVIDE STICKY
MATS (CHANGED END
OF SHIFT OR MORE IF
NECESSARY TO
MAINTAIN
CLEANLINESS).
HEPA NEGATIVE
AIR UNIT
SUPPLY DUCTS
EITHER KEEP
RUNNING OR COVER
WHEN RUNNING TO
KEEP DUST OUT
COVER ALL RETURNS
AT THE
GRATE/DIFFUSERS
F L E
X D
U C
T
SUSPENDED PLASTIC
ZIPPER WALL
CURTAIN BARRIER
POST ICRA, ILSM, FIRE
INPECTION SHEETS
VISIBLE TO PUBLIC
FIRE PULL
STATION WITH
AUDIO / VISUAL
G-101
A P
P R
O X
A .F
.F
SUSPENDED
PLASTIC ZIPPER
WALL CURTAIN
BARRIER
POST ICRA,
ILSM, FIRE
INSPECTION
SHEETS VISIBLE
TO PUBLIC
G-101
ILSM SIGNAGE
INTERIM LIFE SAFETY MEASURES IN EFFECT FOR THE
UPGRADE HVAC RME CLOSETS PROJECT
• THIS EXIT IS CLOSED AND LEADS TO A
CONSTRUCTION AREA
• PLEASE USE ALTERNATE EXITS AS MARKED
1'-5"
ICRA, ILSM, FIRE WATCH AND
MISC. FORMS
PAPER
CADDY
ISLM TEMPORARY BARRIER TAG
PROJECT:
PRIME CONTRACTOR:
SUB CONTRACTOR:
EMERGENCY CONTACT NO.:
BARRIER INSTALLATION DATE:
BARRIER EXPIRATION DATE:
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
LAR
E GI H,NC
N
ED
M RU
P
Y
RE
G
IS
TER
ED ARCHITECT
N O R
T H CA RO
L
I N A
NY
H
M
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:2
:1
P
M
G-101
INFECTION CONTROL RISK
ASSESSMENT (ICRA)
3 4DMM EGS
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON RD, MURFREESBORO,
TN 37129
04/01/2019
BID DOCUMENTS
626-30818-262
GENERAL
1. SEE SHEET GI003 FOR PRE-CONSTRUCTION RISK
ASSESSMENT FORMS AND INFECTION CONTROL
PRECAUTIONS.
2. SEE SHEET GI005 FOR PHASING PLANS AND
DESCRIPTION.
3. ALL APPLICABLE PERMITS AND COR APPROVALS
SHALL BE COMPLETED PRIOR TO BEGINNING ANY
WORK FOR EACH PHASE. PERMITS INCLUDE: ICRA,
ILSM, ABOVE CEILING FIRE/SMOKE WALL, UTILITY,
FIRE ALARM SYSTEM, MEDICAL GASES, AND
CONFINED SPACES.
4. WORK REQUIRED BY INFECTION CONTROL SHALL
BE PERFORMED FOR EACH PHASE OF THE
PROJECT.
Scale: 3/4" = 1'-0"
ICRA BARRIER WALL TYPES
Scale: 1/2" = 1'-0"
CROSS SECTION 'A'
Scale: 1/2" = 1'-0"
TYPICAL CONSTRUCTION PLAN LAYOUT
Scale: 1/2" = 1'-0"
ROOM ELEVATION
Scale: 6" = 1'-0"
ILSM SIGNAGE
Scale: 12" = 1'-0"
ILSM TEMPORARY BARRIER TAG
SS SSSSSSSS
SS SS
SS SS
SS
SS S
S S
S S
SS
S S
95'
COMMON PATH
OF TRAVEL
158'
TOTAL EXIT
PATH DISTANCE
IV
ANTEROOM
G12DD
IV
BUFFER
G12MM
IV
BUFFER
G12CC
OPEN
STORAGE
G12Z
OFFICE
G12AA
BCG
G12FF
HD
BUFFER
G12HH HD
ANTEROOM
G12GG
HD
STORAGE
G12X
RECEIVING
TEARDOWN
G12V
DELIVERY/
RECYCLING
/WASTE
PICKUP
G12U
COMPLIANCE
OFFICE
G12NN
OPEN
STORAGE
G12Z
CORR
G12W
TRAVEL DISTANCE
F.E.C.
NEW EXISTING
/8
3 HOUR FIRE/SMOKE SEPARATION
2 HOUR FIRE/SMOKE SEPARATION
1 HOUR FIRE SEPARATION
1 HOUR SMOKE RATED
SMOKE RATED
EGRESS PATH
EGRESS PATH TAG
EGRESS PATH TAG - COMMON PATH
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER BRACKET
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
EMERGENCY RESPONSE REFERENCE
CONTROLLED ACCESS - ALWAYS
UNLOCKED IN DIRECTION OF EGRESS
KNOX BOX
DELAYED EGRESS W/ ALARM
CA
DE
KB
XXX
XXX
FEB
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH
EGRESS CAPACITY
NOT IN PROJECT SCOPE
IN PROJECT SCOPE
A. SEE SHEETS G0.1 & A0.1 FOR SYMBOLS AND
ABBREVIATIONS.
B. SEE CIVIL DRAWINGS FOR INFORMATION INCLUDING
CONCRETE SIDEWALKS, CONCRETE PADS, AND
PARKING CONFIGURATIONS. CIVIL BACKGROUND
DRAWING INFORMATION IS FOR REFERENCE ONLY.
C. SEE STRUCTURAL DRAWINGS FOR FRAMING
INFORMATION & FRAMING DIMENSIONS. ALL
DIMENSIONS ARE FOR REFERENCE ONLY- VERIFY
ALL FRAMING WITH STRUCTURAL DRAWINGS.
D. REFER TO PLUMBING DRAWINGS FOR INFORMATION
CONCERNING PLUMBING FIXTURES AND PIPING
SYSTEM(S).
E. REFER TO MECHANICAL DRAWINGS FOR
INFORMATION CONCERNING HVAC SYSTEM(S).
F. REFER TO ELECTRICAL DRAWINGS FOR
INFORMATION CONCERNING POWER, LIGHTING AND
COMMUNICATION SYSTEM(S).
G. REFER TO ELECTRICAL DRAWING FOR FIRE ALARM
NOTIFICATION AND EMERGENCY EGRESS LIGHTING
LOCATIONS.
H. REFER TO PARTITION TYPES FOR FURTHER FIRE
SEPARATION REQUIREMENTS.
I. CONTRACTOR TO PROVIDE ALL ADDITIONAL
FRAMING NECESSARY FOR ALL OPENINGS AND
SUPPLEMENTAL FRAMING ABOVE PARTITIONS.
J. ALL FIRE RATED ASSEMBLIES SHALL BE INSTALLED
IN STRICT ACCORDANCE WITH TESTED ASSEMBLIES
INDICATED.
K. EXTEND EXTEND FIRE RATED PARTITIONS,
BARRIERS, AND OTHER SEPARATIONS TO BOTTOM
OF ROOF/FLOOR DECK ABOVE (OR AS DIRECTED BY
UL ASSEMBLY) AND TO EXTERIOR WALL. SEAL JOINT
BETWEEN EDGES OF PARTITION WITH FIRE RATED
SEALANT AND/OR INTUMESCENT ASSEMBLY.
L. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES
SHALL BE FIRE-SEALED IN ACCORDANCE WITH
APPROVED MANUFACTURER'S DETAIL FOR
LOCATION, TYPE OF CONSTRUCTION, PENETRATING
ITEM AND RATING REQUIRED.
M. ALL DUCTWORK, DIFFUSERS AND GRILLES
PENETRATING FIRE-RATED WALLS, CEILINGS AND
FLOORS SHALL HAVE THE APPROPRIATE TYPE OF
FIRE/SMOKE DAMPER IN ACCORDANCE WITH THE
TYPE OF CONSTRUCTION BEING PENETRATED AND
THE FIRE/SMOKE RATING REQUIRED.
N. ALL LIGHT FIXTURES AND ELECTRICAL DEVICES
PENETRATING FIRE-RATED ASSEMBLIES SHALL BE
UL-LISTED FOR INSTALLATION IN THE ASSEMBLY OR
SHALL BE INSTALLED SUCH THAT THE FIRE-RATING
IS NOT COMPROMISED.
O. SMOKE RESISTANT CONSTRUCTION SHALL MEET
THE REQUIREMENTS OF ALL APPLICABLE CODES.
AREA SHALL BE SEPARATED FROM THE REMAINDER
OF THE BUILDING BE CONSTRUCTION CAPABLE OF
RESISTING THE PASSAGE OF SMOKE. THE
PARTITIONS SHALL EXTEND FROM THE FLOOR TO
THE UNDERSIDE OF THE FLOOR OR ROOF
ASSEMBLY ABOVE. DOORS SHALL BE SELF OR
AUTOMATIC CLOSING. DOORS SHALL NOT HAVE AIR
TRANSFER OPENINGS AND SHALL NOT BE
UNDERCUT IN EXCESS OF CLEARANCE PERMITTED
WITH ACCORDANCE TO NFPA 80.
P. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE
LIQUIDS IS UNDERSTOOD TO NOT BE WITHIN THE
BUILDING. STORAGE OF ANY MATERIAL IS TO BE IN
COMPLIANCE WITH ALL APPLICABLE CODES AND
AUTHORITIES HAVING JURISDICTION.
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
LAR
E GI H,NC
N
ED
M RU
P
Y
RE
G
IS
TER
ED ARCHITECT
N O R
T H CA RO
L
I N A
NY
H
M
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREAS S S S
/2
/2
:2
:1
P
M
LS101
GROUND FLOOR LIFE SAFETY
4 4DMM EGS
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON RD, MURFREESBORO,
TN 37129
04/01/2019
BID DOCUMENTS
626-30818-262
PROPOSED USE:
OWNED BY: STATE
CODE ENFORCEMENT JURISDICTION: CITY
COUNTY
APPLICABLE CODES:
GENERAL CODE INFORMATION:
NEW CONSTRUCTION
CONSTRUCTION TYPE:
PRIMARY OCCUPANCY:
SECONDARY OCCUPANCY:
PROJECT NAME:
PROJECT ADDRESS:
OWNER OR AGENT:
20XX INTERNATIONAL BUIDLING CODE
(VERSION) PLUMBING CODE
20XX INTERNATIONAL ENERGY CONSERVATION CODE
20XX INTERNATIONAL MECHANICAL CODE
20XX INTERNATIONAL FIRE CODE
20XX NATIONAL ELECTRIC CODE
(VERSION) ACCESSIBILITY CODE
20XX NFPA LIFE SAFETY CODE
20XX (VERSION) OTHER CODE 1
20XX (VERSION) OTHER CODE 2
20XX (VERSION) OTHER CODE 3
(VERSION) ACCESSIBILITY CODE 2
USP 800 PHARMACY COMPLIANCE FOR
YORK VAMC - TVHS
3400 LEBANON RD, MURFREESBORO, TN
37129
Owner
CODE INFORMATION
0 2 4 8
NORTH
PLAN
Scale: 1/4" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN
LIFE SAFETY LEGEND
EGRESS PATH "A"
COMMON 95'
EGRESS PATH "B"
TOTAL 183'
GROSS AREA
FIRST
FLOOR 5745 SQ. FT.
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
NEW CONSTRUCTION
FIRST
FLOOR 1988 SQ. FT.
LEGEND
01 ICRA BARRIER TYPE 1 - SEE G-101 FOR DETAIL
02 PROVIDE STICKY FLOOR MAT AT WORK AREA
ENTRY.
SHEET KEY NOTES#
W
W
W
W
W W
WW
W
W
J B
T O
P
I N
V
I N
A
I N
V
I N
B
I N
V
O
U T
A
B
U N
A B
L E
T
O
D
E T
E R
M I N
E
P
I P
E
S I Z
E
A
N D
M
A T
E R
I A
L
D U
E
T
O
P
I P
E
P
L A
C E
M E
I
M A
N H
O L E
12"CLAY
C
L
A
Y
H
W
H
W
H
W
H
W
H
W
H
W
H
W
CONCRETE LOOP ROAD
M U
L T
I
S
T O
R Y
B
I C
K
588.0
J B
T O
P
I N
V
I N
A
I N
V
I N
B
I N
V
I N
C
I N
V
I N
D
I N
V
O
U T
D
I
P
D
I
P
C
L A
Y
B
C
D
C
L
A
Y
W
W
W
A T
V
L V
E
M A
N H
O L E
B E
N C
H M
A R
K
R
E B
B L U
E
P
L A
S T
C
P
E L E
V
S I G
N
B U
I L D
I N
G
D
I R
E C
T I O
N
F F
E
F F
E
F F
E
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD LO
D
LO
D
LOD LOD LOD LOD
LO
D
LO
D
LOD LOD LOD
LO
D
LO
D
LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
DLODLODLODLODLODLODLODLOD
LO
D
LO
D
LO
D
LO
D
EXISTING 5' CONCRETE
WALK TO BE REMOVED TO
ALLOW FOR CONSTRUCTION
OF THE PROPOSED
BUILDING AND FOOTINGS
EXISTING TREE
TO BE REMOVED WITH MINIMAL
SOIL DISTURBANCE. CONTRACTOR
SHALL VERIFY WITH COR PRIOR TO
REMOVAL.
TREE PROTECTION FENCE
(TYP.)
SILT FENCE
(TYP.)
LIMITS OF DISTURBANCE (0.09 AC)
(TYP.)
EXISTING 4" CLAY ROOF DRAIN
TO BE REMOVED
EXISTING 4" CLAY ROOF DRAIN
TO BE REMOVED
EXISTING 4" CLAY ROOF DRAIN
TO REMAIN
EXISTING 6" CLAY ROOF DRAIN
TO BE REMOVED
EXISTING 12" STORMLINE
TO REMAIN
TS
MU
TS
MU
SF
SF
SF
SF
SF SF SF SF SF SF SF SF SF SF
SF
SF
EXISTING SIDEWALK
TO REMAIN
EXISTING TREE
TO REMAIN
EXISTING 12" CLAY PIPE
TO REMAIN
CONTRACTOR IS RESPONSIBLE
FOR MAINTAINING AN EXIT PATH
AT ALL TIMES DURING
CONSTRUCTION.
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
VA FORM 08-6231
Office of
Construction and Facilities
Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
NSY ZR
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON ROAD, MURFREESBORO,
TN 37129
04/01/2019
BID DOCUMENTS
626-308
18-262
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
Foresite Group, Inc.
2128 Moores Mill Rd.
Suite C Auburn, AL 36830 o | 334.887.6064 f | 334.887.6024 w | www.fg-inc.net
DEMOLITION PLAN
C-1
GENERAL NOTES:
1) THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE DEMOLITION PERMIT PRIOR TO
DEMOLITION OF THE SITE.
2) ALL INITIAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED PRIOR
TO ANY WORK INCLUDING DEMOLITION.
3) ALL CONSTRUCTION RELATED PERMITS DURING THE CONSTRUCTION PHASE OF THIS
PROJECT ARE THE RESPONSIBILITY OF THE CONTRACTOR.
4) REMOVE SHRUBS AND TREES AS NOTED. GRUB OUT ROOTS AND STUMPS AND LEGALLY
DISPOSE OF DEBRIS.
DEMOLITION NOTES:
1) ALL NEW WORK SHOWN IN THESE SHEETS SHALL COMPLY WITH APPLICABLE STATE,
FEDERAL, AND LOCAL BUILDING AND UTILITY INSTALLATION CODES.
2) THERE MAY BE ADDITIONAL UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER
ASSUMES NO RESPONSIBILITY FOR LOCATIONS SHOWN, AND IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE LOCATIONS OF ALL UTILITIES
WITHIN THE LIMITS OF CONSTRUCTION AND TO NOTIFY THE OWNER IN CASE OF
DISCREPANCIES THAT AFFECT THE CONSTRUCTION PROJECT.
3) THE CONTRACTOR IS RESPONSIBLE FOR NOTIFICATION OF AND LIAISON WITH UTILITY
COMPANIES IN THE PROCESS OF LOCATION AND RELOCATION OF AND TIE-IN TO PUBLIC
UTILITIES.
4) CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE THAT MAY OCCUR TO ANY ADJACENT
STRUCTURES OR PROPERTY, OR ANY EXISTING STRUCTURES WITHIN LIMITS OF
CONSTRUCTION THAT ARE DESIGNATED ON THE PLANS TO REMAIN, AND SHALL REPAIR OR
REPLACE SUCH DAMAGED PROPERTY TO THE PROPERTY OWNER'S SATISFACTION AT NO
COST TO THE OWNER.
5) THE CONTRACTOR SHALL NOT DEVIATE FROM THESE PLANS AND SPECIFICATIONS
WITHOUT THE PRIOR WRITTEN CONSENT OF THE ENGINEER.
6) THE CONTRACTOR SHALL SEQUENCE THE WORK AND PROVIDE TEMPORARY MEASURES
AS NECESSARY TO MAINTAIN ACCESS TO THE SITE THROUGH ALL ENTRANCES AT ALL TIMES
DURING CONSTRUCTION. TEMPORARY PROVISIONS MAY INCLUDE, BUT ARE NOT LIMITED TO:
BARRICADES, FLASHING LIGHTS, FLAGMAN, TEMPORARY PAVEMENT, AND DIRECTIONAL
SIGNAGE AS NECESSARY TO ACCOMPLISH THE WORK.
7) CONTRACTOR SHALL CONSIDER COORDINATION ASPECTS OF CRANES AND
CONSTRUCTION EQUIPMENT OPERATIONS DURING DEMOLITION ACTIVITY.
8) CONTRACTOR EQUIPMENT SHALL NOT BE PARKED IN COUNTY, CITY OR STATE
RIGHT-OF-WAY, AND MUST BE STORED WITHIN SITE.
9) ALL BUFFERS AND SAVE AREAS SHALL BE CLEARLY IDENTIFIED BY FLAGGING AND/OR
FENCING PRIOR TO COMMENCEMENT OF ANY LAND DISTURBANCE.
10) THE CONTRACTOR SHALL DISPOSE OF ANY HAZARDOUS MATERIALS IN STRICT
ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL LAWS.
11) ALL ITEMS DESIGNATED FOR REMOVAL SHALL BE LEGALLY DISPOSED OF, OFF SITE.
12) CONTRACTOR TO CONTACT UTILITIES PROTECTION CENTER PRIOR TO ANY EXCAVATION.
13) CONTRACTOR TO POT HOLE EXISTING WATER LINE, UNDERGROUND ELECTRICAL LINES,
GAS LINE, UNDERGROUND TELEPHONE, FIBER OPTIC, AND ANY OTHER UTILITY LINES WITHIN
THE RIGHT OF WAY DURING DEMOLITION ACTIVITIES AND COORDINATE FIELD LOCATIONS AND
DEPTHS OF THESE UTILITIES WITH ENGINEER FOR PROPOSED UTILITY CROSSINGS AND
PROPOSED PAVEMENT OVER EXISTING LINES. THESE LINES MAY REQUIRE RELOCATION.
EROSION CONTROL NOTES
(SEE ALSO EROSION CONTROL PLAN)
1) EROSION CONTROL DEVICES ARE TO BE INSTALLED PRIOR TO ANY CLEARING OR
EARTHWORK OPERATIONS AND SHALL BE MAINTAINED THROUGHOUT CONSTRUCTION AND
UNTIL PERMANENT GROUND COVER IS ESTABLISHED IN ALL DISTURBED AREAS.
2) THE CONTRACTOR SHALL PROVIDE DUST CONTROL AND SHALL PROTECT ADJACENT
PAVEMENTS FROM SOIL ACCUMULATION DURING CONSTRUCTION.
3) ADDITIONAL EROSION CONTROL DEVICES MAY BE REQUIRED BY THE ENGINEER OR
OTHER INSPECTORS AS DETERMINED BY FIELD CONDITIONS.
LEGEND
UTILITIES, FENCE, AND/OR WALL TO BE REMOVED
AND/OR RELOCATED. SEE NOTE FOR DETAIL.
BUILDING/CONCRETE TO BE REMOVED
LIMITS OF DISTURBANCE
TREE PROTECTION FENCE
EXISTING TREE TO BE REMOVED
LOD LOD LOD
PS PS
STABILIZATION PRACTICES
CODE PRACTICE DETAIL SYMBOL DESCRIPTION
DISTURBED AREA
STABILIZATION (WITH
MULCHING ONLY)
ESTABLISHING TEMPORARY PROTECTION FOR DISTURBED
AREAS WHERE SEEDLINGS MAY NOT HAVE A SUITABLE
GROWING SEASON TO PRODUCE AN EROSION RETARDING
COVER.
DISTURBED AREA
STABILIZATION (WITH
TEMPORARY SEEDING)
ESTABLISHING A TEMPORARY VEGETATIVE COVER WITH FAST
GROWING SEEDING ON DISTURBED AREAS.
DISTURBED AREA
STABILIZATION (WITH
PERMANENT VEGETATION)
ESTABLISHING A PERMANENT VEGETATIVE COVER SUCH AS
TREES, SHRUBS, VINES, GRASSES, OR LEGUMES ON
DISTURBED AREAS.
MU MU
SEDIMENT CONTROL PRACTICES
CODE PRACTICE DETAIL SYMBOL DESCRIPTION
SILT FENCE
A BARRIER TO PREVENT SEDIMENT FROM LEAVING THE
CONSTRUCTION SITE. IT MAY BE SANDBAGS, BALES OF STRAW
OR HAY, BRUSH, LOGS AND POLES, GRAVEL, OR A SILT FENCE.
SF
SF
TS TS
1" = 10'
SCALE IN FEET
10 5 10 20
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
FH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
JB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text (A)
AutoCAD SHX Text
JB
W
W
W
W W
WW
W
W
J B
T O
P
I N
V
I N
A
I N
V
I N
B
I N
V
O
U T
A
B
U N
A B
O
D
E T
E R
M I N
E
P
I P
E
S I Z
E
A
T
E R
I A
L
D U
E
T
O
P
I P
E
P
L A
C E
M E
M A
N H
O L E
12"CLAY
C
L
A
Y
H
W
H
W
H
W
H
W
H
W
H
W
CONCRETE LOOP ROAD
M U
L T
I
S
T O
Y
B
I C
K
588.0
J B
T O
P
I N
V
I N
A
I N
V
I N
B
I N
V
I N
C
I N
V
I N
D
I N
V
O
U T
D
I
P
D
I
P
C
L A
Y
B
C
D
C
L
A
Y
W
W
W
A T
V
L V
E
M A
N H
O L E
B E
N C
H M
A R
K
R
E B
B L U
E
P
L A
S T
P
E L E
V
S I G
N
B U
I L D
I N
G
D
I R
E C
T I O
N
F F
E
F F
E
F F
E
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD LO
D
LO
D
LOD LOD LOD LOD
LO
D
LO
D
LOD LOD LOD
LO
D
LO
D
LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
DLODLODLODLODLODLODLODLOD
LO
D
LO
D
LO
D
LO
D
6" TRENCH DRAIN WITH
GALVANIZED STEEL
PERFORATED GRATE TOP
PROPOSED 10' WIDE CONCRETE RAMP TO SLOPE
DOWN FROM EXISTING SIDEWALK TO TRENCH DRAIN
(SEE STRUCTURAL PLANS FOR DESIGN OF RAMP)
6" PVC ROOF DRAIN
CONNECT TO EXISTING 12" STORM LINE
LANDSCAPING TO SLOPE AWAY
FROM PROPOSED BUILDING
LANDSCAPING TO SLOPE AWAY
FROM PROPOSED BUILDING
EXISTING 4" CLAY ROOFDRAIN
EXISTING 12" CLAY STORMLINE
TO REMAIN
EXISTING 8" CLAY STORMLINE
EXISTING STORM MANHOLE
EXISTING 12" CLAY STORMLINE
EXISTING STORM MANHOLE
EXISTING 12" CLAY STORMLINE
TREE PROTECTION FENCE
(TYP.)
SILT FENCE
(TYP.)
LIMITS OF DISTURBANCE (0.09 AC)
(TYP.)
PS
PS
ENCLOSURE WITH GATE
(SEE ARCHITECTURAL PLANS)
THIS AREA MUST BE GRADED AND
DRAINED APPROPRIATELY AS TO
NOT TRAP STORMWATER.
PROPOSED 6" PVC ROOFDRAIN (TYP.)
SF
SF
SF
SF SF SF SF SF SF SF SF SF
SF
SF
SF
PROPOSED 12" NYLOPLAST
DRAINAGE INLET
CONTRACTOR SHALL TIE EXISTING ROOF
DRAIN INTO NEW INLET STRUCTURE.
PROPOSED DOGHOUSE
MANHOLE
6'
FFE = 586.71
587.57
587.56
586.59
586.71
587.84
586.59
586.71
586.71
587.64 587.66
587.82
587.42
587.51
588.07
588.15
588.10
588.19
588.57
588.51
588.45
588.55588.80
588.80
588.38
588.52
588.41
PROPOSED PVC FOUNDATION DRAIN
LEADER. SEE ARCHITECTURAL PLANS FOR
FOUNDATION DRAIN DETAILS
PROPOSED 12" NYLOPLAST
DRAINAGE INLET
CONTRACTOR IS RESPONSIBLE
FOR MAINTAINING AN EXIT PATH
AT ALL TIMES DURING
CONSTRUCTION.
GENERAL NOTES:
1) CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES BETWEEN THE EXISTING
CONDITIONS IN THE FIELD AND THE SURVEY SHOWN ON THE PLANS BEFORE PROCEEDING
WITH ANY NEW CONSTRUCTION.
2) CONTRACTOR IS RESPONSIBLE FOR CORRECT HORIZONTAL AND VERTICAL ALIGNMENT
OF ALL TIES BETWEEN PROPOSED AND EXISTING PAVEMENTS, CURB AND GUTTER,
SIDEWALKS, WALLS, AND UTILITIES.
SITE NOTES:
1) SEE ARCHITECTURAL PLANS FOR BUILDING FLOOR PLAN DIMENSIONS, DOOR LOCATIONS,
SITE LIGHTING PLAN, AND OTHER ARCHITECTURAL DETAILS.
2) ALL BUFFERS, TREE SAVE AREAS, AND UNDISTURBED AREAS SHALL BE CLEARLY
IDENTIFIED BY FLAGGING AND/OR FENCING PRIOR TO COMMENCEMENT OF ANY LAND
DISTURBANCE.
3) ALL EROSION, SEDIMENT CONTROL AND TREE PROTECTION MEASURES SHALL BE
INSTALLED PRIOR TO ANY GRADING.
4) MAXIMUM CUT OR FILL SLOPE=2H:IV
GRADING NOTES:
1) NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED UNTIL ALL SITE IMPROVEMENTS HAVE
BEEN COMPLETED.
2) MAXIMUM CUT OR FILL SLOPES IS 2H:1V
3) TREE PROTECTION FENCE SHALL BE INSTALLED PRIOR TO ANY CLEARING OR GRADING
ACTIVITIES.
4) ALL PLASTIC STORM PIPE SHOWN ON THIS PLAN SHALL BE WRAPPED WITH LOCATION
WIRE AND TAPE.
5) IN ALL AREAS OF FILL OR OTHERWISE DISTURBANCE OF EXISTING CONDITIONS, UNLESS
OTHERWISE NOTED, THE CONTRACTOR SHALL FULLY AND COMPLETELY REMOVE AND
LEGALLY DISPOSE OFF-SITE, ALL PLANT MATERIALS INCLUDING BUT NOT LIMITED TO ROOT
SYSTEMS, CONCRETE, REINFORCED CONCRETE, ASPHALT DEBRIS, UNDERBRUSH, TOPSOIL,
AND OTHER DELETERIOUS MATERIAL. THE SUBGRADE TO REMAIN SHALL BE COMPACTED TO
95% STANDARD PROCTOR MAXIMUM DRY DENSITY FOLLOWING FULL REMOVAL OF THESE
MATERIALS.
6) REFER TO SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION
REPORTS AS PROVIDED BY TERRACON DATED DECEMBER 24, 2018 FOR RECOMMENDATIONS
ASSOCIATED WITH: GENERAL SITE PREPARATION, BUILDING PAD PREPARATION, SUBGRADE
PREP, AREAS TO RECEIVE FILL, AREAS TO BE OVEREXCAVATED, PAVEMENT SECTIONS, FILL,
SLOPES AND EXCAVATION. THE CONTRACTOR SHALL HAVE THIS REPORT ON THE JOB SITE
FOR REFERENCE AT ALL TIMES. THE CONTRACTOR SHALL PROVIDE EARTHWORK
OPERATIONS AND CONSTRUCTION PHASE MONITORING TO ENSURE THAT ALL COMPACTION IS
COMPLETED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. THE CONTRACTOR SHALL
PROVIDE TESTING REPORTS TO THE OWNER REGARDING COMPACTION TESTING PER THE
TESTING PROTOCOL IN THE GEOTECHNICAL REPORT.
7) IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN QUALIFIED PROFESSIONAL
ADVICE WHEN QUESTIONS ARISE CONCERNING DESIGN AND EFFECTIVENESS OF EROSION
CONTROL DEVICES.
8) EROSION CONTROL MEASURES ARE TO BE ACCOMPLISHED PRIOR TO ANY OTHER
CONSTRUCTION ON THE SITE AND MAINTAINED UNTIL PERMANENT GROUND COVER IS
ESTABLISHED.
9) CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES SHOWN ON THE PLANS BY
POT HOLING THE LINES. THE CONTRACTOR SHALL HAVE THE LINES SURVEYED, INCLUDING
HORIZONTAL AND VERTICAL LOCATION, AND THE SURVEYED POINTS SENT TO THE PROJECT
ENGINEER TO DETERMINE IF ANY UTILITY CONFLICTS WILL AFFECT THE CURRENT STORM
DRAINAGE DESIGN.
LEGEND
EXISTING STORM PIPE
PROPOSED STORM PIPE
CONCRETE SIDEWALK PAVING
LIMITS OF DISTURBANCE
TREE PROTECTION FENCE
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
VA FORM 08-6231
Office of
Construction and Facilities
Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
NSY ZR
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON ROAD, MURFREESBORO,
TN 37129
04/01/2019
BID DOCUMENTS
626-308
18-262
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
Foresite Group, Inc.
2128 Moores Mill Rd.
Suite C Auburn, AL 36830 o | 334.887.6064 f | 334.887.6024 w | www.fg-inc.net
SITE & GRADING PLAN
C-2
LODLODLOD
PS PS
STABILIZATION PRACTICES
CODE PRACTICE DETAIL SYMBOL DESCRIPTION
DISTURBED AREA
STABILIZATION (WITH
MULCHING ONLY)
ESTABLISHING TEMPORARY PROTECTION FOR DISTURBED
AREAS WHERE SEEDLINGS MAY NOT HAVE A SUITABLE
GROWING SEASON TO PRODUCE AN EROSION RETARDING
COVER.
DISTURBED AREA
STABILIZATION (WITH
TEMPORARY SEEDING)
ESTABLISHING A TEMPORARY VEGETATIVE COVER WITH FAST
GROWING SEEDING ON DISTURBED AREAS.
DISTURBED AREA
STABILIZATION (WITH
PERMANENT VEGETATION)
ESTABLISHING A PERMANENT VEGETATIVE COVER SUCH AS
TREES, SHRUBS, VINES, GRASSES, OR LEGUMES ON
DISTURBED AREAS.
MU MU
SEDIMENT CONTROL PRACTICES
CODE PRACTICE DETAIL SYMBOL DESCRIPTION
SILT FENCE
A BARRIER TO PREVENT SEDIMENT FROM LEAVING THE
CONSTRUCTION SITE. IT MAY BE SANDBAGS, BALES OF STRAW
OR HAY, BRUSH, LOGS AND POLES, GRAVEL, OR A SILT FENCE.
SF
SF
TS TS
1" = 10'
SCALE IN FEET
10 5 10 20
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
FH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
JB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text (A)
JB
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
VA FORM 08-6231
Office of
Construction and Facilities
Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
NSY ZR
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON ROAD, MURFREESBORO,
TN 37129
04/01/2019
BID DOCUMENTS
626-308
18-262
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
Foresite Group, Inc.
2128 Moores Mill Rd.
Suite C Auburn, AL 36830 o | 334.887.6064 f | 334.887.6024 w | www.fg-inc.net
CONSTRUCTION DETAILS
C-3
MULCH MATERIALS AND APPLICATION RATES
MATERIAL RATE
STRAW OR HAY 2-4" DEEP
WOOD WASTE, CHIPS,
SAW DUST, OR BARK
2-3" DEEP (ABOUT 6-9 TONS/ACRE)
MATTING OR NETTING ACCORDING TO MANUFACTURER
RECOMMENDATIONS
POLYETHYLENE FILM CAN BE LAID OVER SENSITIVE AREAS
AND STOCKPILES, MUST BE
SECURED.
MULCHING FOR TEMPORARY STABILIZATION
WITHOUT VEGETATION
WHEN MULCH IS USED WITHOUT SEEDING, MULCH SHALL BE APPLIED TO PROVIDE
FULL COVERAGE OF THE EXPOSED AREA.
SITE PREPARATION
1. GRADE TO PERMIT THE USE OF EQUIPMENT FOR APPLYING AND
ANCHORING MULCH.
2. INSTALL NEEDED EROSION CONTROL MEASURES AS REQUIRED SUCH AS
DIKES, DIVERSIONS, BERMS, TERRACES AND SEDIMENT BARRIERS.
3. LOOSEN COMPACT SOIL TO A MINIMUM DEPTH OF 3 INCHES.
APPLICATION
1. DRY STRAW OR HAY MULCH AND WOOD CHIPS SHALL BE APPLIED
UNIFORMLY BY HAND OR BY MECHANICAL EQUIPMENT.
2. IF THE AREA WILL EVENTUALLY BE COVERED WITH PERENNIAL
VEGETATION, ADD 20-30 POUNDS OF NITROGEN PER ACRE IN ADDITION TO
THE NORMAL AMOUNT.
ANCHORING MULCH
1. STRAW OR HAY MULCH CAN BE PRESSED INTO THE SOIL WITH A DISK
HARROW WITH THE DISK SET STRAIGHT OR WITH A SPECIAL "PACKER
DISK." DISKS MAY BE SMOOTH OR SERRATED AND SHOULD BE 20 INCHES
OR MORE IN DIAMETER AND 8 TO 12 INCHES APART. THE EDGES OF THE
DISK SHOULD BE DULL ENOUGH NOT TO CUT THE MULCH BUT TO PRESS IT
INTO THE SOIL LEAVING MUCH OF IT IN AN ERECT POSITION. STRAW OR
HAY MULCH SHALL BE ANCHORED IMMEDIATELY AFTER APPLICATION.
2. STRAW OR HAY MULCH SPREAD WITH SPECIAL BLOWER-TYPE EQUIPMENT
MAY BE ANCHORED WITH EMULSIFIED ASPHALT (GRADE AE-5 OR SS-1. THE
ASPHALT EMULSION SHALL BE SPRAYED ONTO THE MULCH AS IT IS
EJECTED FROM THE MACHINE. USE 100 GALLONS OF EMULSIFIED ASPHALT
AND 100 GALLONS OF WATER PER TON OF MULCH. TACKIFERS AND
BINDERS CAN BE SUBSTITUTED FOR EMULSIFIED ASPHALT. PLEASE REFER
TO SPECIFICATION TB - TACKIFERS AND BINDERS. PLASTIC MESH OR
NETTING WITH MESH NO LARGER THAN ONE INCH BY ONE INCH SHALL BE
INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS.
3. NETTING OF THE APPROPRIATE SIZE SHALL BE USED TO ANCHOR WOOD
WASTE. OPENINGS OF THE NETTING SHALL NOT BE LARGER THAN THE
AVERAGE SIZE OF THE WOOD WASTE CHIPS.
4. POLYETHYLENE FILM SHALL BE ANCHOR TRENCHED AT THE TOP AS WELL
AS INCREMENTALLY AS NECESSARY.
DISTURBED AREA STABILIZATION (WITH
TEMPORARY SEEDING)
GRADING AND SHAPING
1. EXCESSIVE WATER RUNOFF SHALL BE REDUCED BY PRACTICES SUCH
AS CLOSED DRAINS, DITCHES, DIKES, DIVERSIONS, AND OTHERS
2. NO SHAPING OR GRADING IS REQUIRED IF SLOPES CAN BE STABILIZED
BY HAND-SEEDED VEGETATION OR IF HYDRAULIC SEEDING EQUIPMENT
IS TO BE USED.
SEEDBED PREPARATION
1. WHEN A HYDRAULIC SEEDER IS USED, SEEDBED PREPARATION IS NOT
REQUIRED. WHEN USING CONVENTIONAL OR HAND-SEEDING, SEEDBED
PREPARATION IS NOT REQUIRED IF THE SOIL MATERIAL IS LOOSE AND
NOT SEALED BY RAINFALL.
2. WHEN SOIL HAS BEEN SEALED BY RAINFALL OR CONSISTS OF SMOOTH
CUT SLOPES, THE SOIL SHALL BE PITTED, TRENCHED OR OTHERWISE
SCARIFIED TO PROVIDE A PLACE FOR SEED TO LODGE AND
GERMINATE.
LIME AND FERTILIZER
1. SOIL TESTS MUST BE PERFORMED DETERMINE THE REQUIRED
AMOUNTS OF FERTILIZER, LIME, AND OTHER AMENDMENTS. SOIL TESTS
SHOULD INCLUDE RECOMMENDATIONS FOR APPLICATION RATES.
2. APPLY AGRICULTURAL LIME AT A RATE DETERMINED BY SOIL TEST FOR
PH. QUICK ACTING LIME SHOULD BE INCORPORATED TO MODIFY PH
DURING THE GERMINATION PERIOD.
3. ALL GRADED AREAS REQUIRE LIME APPLICATION UNLESS SOIL TEST
INDICATE OTHERWISE.
4. BIOSTIMULANTS SHOULD ALSO BE CONSIDERED WHEN THERE IS LESS
THAN 3% ORGANIC MATTER IN THE SOIL.
5. FERTILIZER SHOULD BE APPLIED BEFORE SEEDBED PREPARATION AND
INCORPORATED WITH A DISK, RIPPER, OR CHISEL. ON SLOPES TOO
STEEP FOR, OR INACCESSIBLE TO EQUIPMENT, FERTILIZER SHALL BE
HYDRAULICALLY APPLIED, PREFERABLY IN THE FIRST PASS WITH SEED
AND SOME HYDRAULIC MULCH, THEN TOPPED WITH THE REMAINING
REQUIRED APPLICATION RATE.
6. FOR LOW FERTILITY SOILS, AGRICULTURAL LIME & FERTILIZER
REQUIRED UNLESS SOIL TESTS SHOW IT IS NOT REQUIRED AND THAT
SOILS ARE REASONABLY FERTILE. FOR LOW FERTILITY SOILS, APPLY
10-10-10 FERTILIZER AT 500-700 LB/ACRE. APPLY AGRICULTURAL LIME
AT 1 TON PER ACRE.
SEEDING
SELECT A GRASS OR GRASS-LEGUME MIXTURE SUITABLE TO THE AREA
AND SEASON OF THE YEAR. SEED SHALL BE APPLIED UNIFORMLY BY HAND,
CYCLONE SEEDER, DRILL, CULTIPACKER-SEEDER, OR HYDRAULIC SEEDER
(SLURRY INCLUDING SEED AND FERTILIZER). DRILL OR
CULTIPACKER-SEEDERS SHOULD NORMALLY PLACE SEED ONE-QUARTER
TO ONE-HALF INCH DEEP. APPROPRIATE DEPTH OF PLANTING IS TEN
TIMES THE SEED DIAMETER. SOIL SHOULD BE “RAKED” LIGHTLY TO COVER
SEED WITH SOIL IF SEEDED BY HAND.
MULCHING
TEMPORARY VEGETATION CAN, IN MOST CASES, BE ESTABLISHED
WITHOUT THE USE OF MULCH, PROVIDED THERE IS LITTLE TO NO EROSION
POTENTIAL. HOWEVER, THE USE OF MULCH CAN OFTEN ACCELERATE AND
ENHANCE GERMINATION AND VEGETATION ESTABLISHMENT. MULCH
WITHOUT SEEDING SHOULD BE CONSIDERED FOR SHORT TERM
PROTECTION. REFER TO DS1 - DISTURBED AREA STABILIZATION (Ds1).
IRRIGATION
DURING TIMES OF DROUGHT, WATER SHALL BE APPLIED AT A RATE NOT
CAUSING RUNOFF AND EROSION. THE SOIL SHALL BE THOROUGHLY
WETTED TO A DEPTH THAT WILL INSURE GERMINATION OF THE SEED.
SUBSEQUENT APPLICATIONS SHOULD BE MADE WHEN NEEDED.
DISTURBED AREA STABILIZATION (WITH TEMPORARY SEEDING)
SPECIES
SEEDING
RATE PER
1,000 S.F.
SEEDING
RATE PER
ACRE*
PLANTING DATES
MTNS./
LIMESTONE
PIEDMONT COASTAL
BARLEY (ALONE)
(IN MIXTURE)
3.3 LBS.
0.6 LBS.
3 bu.
1/2 bu.
9/1-10/31 9/15-11/15 10/1-12/31
RYE (ALONE)
(IN MIXTURE)
3.9 LBS.
0.6 LBS.
3 bu.
1/2 bu.
8/15-10/31 9/15-11/30 10/1-12/31
ANNUAL RYEGRASS ALONE 0.9 LBS. 40 LBS. 8/15-11/15 9/1-12/15 9/15-12/31
ANNUAL LESPEDEZA (ALONE)
(IN MIXTURE)
0.9 LBS.
0.2 LBS.
40 LBS.
10 LBS.
3/1-3/31 3/1-3/31 2/1-2/28
WEEPING
LOVEGRASS
(ALONE)
(IN MIXTURE)
0.1 LBS.
0.05 LBS.
4 LBS.
2 LBS.
4/1-5/31 4/1-5/31 3/1-5/31
SUDANGRASS 1.4 LBS. 60 LBS. 5/1-7/31 5/1-7/31 4/1-7/31
BROWN TOP MILLET (ALONE)
(IN MIXTURE)
0.9 LBS.
0.2 LBS.
40 LBS.
10 LBS.
4/15-6/15 4/15-6/60 4/15-6/30
WHEAT (ALONE)
(IN MIXTURE)
4.1 LBS.
0.7 LBS.
3 bu.
1/2 bu.
9/15-11/30 10/1-12-15 10/15-12/31
1. UNUSUAL SITE CONDITIONS MAY REQUIRE HEAVIER SEEDING RATES.
2. SEEDING DATES MAY NEED TO BE ALTERED TO FIT TEMPERATURE VARIATIONS AND LOCAL CONDITIONS.
3. SEE "THE MANUAL FOR EROSION & SEDIMENT CONTROL IN GEORGIA, SIXTH EDITION" FOR MAJOR LAND
RESOURCE AREAS.
4. SEEDING RATES ARE BASED ON PURE LIVE SEED. (PLS)
DISTURBED AREA STABILIZATION (WITH
PERMANENT VEGETATION)
NOTE THAT IN THE CASE OF DISCREPANCIES BETWEEN ANY OF
THE INFORMATION BELOW AND THE INFORMATION CONTAINED IN
TREE REPLACEMENT AND LANDSCAPE PLANS & DETAILS, THE
LATTER SHALL BE USED.
GRADING AND SHAPING
1. GRADING AND SHAPING MAY NOT BE WHERE HYDRAULIC SEEDING AND
FERTILIZING EQUIPMENT IS TO BE USED. VERTICAL BANKS SHALL BE
SLOPED TO ENABLE PLANT ESTABLISHMENT.
2. WHEN CONVENTIONAL SEEDING AND FERTILIZING ARE TO BE DONE,
GRADE AND SHAPE WHERE SO THAT EQUIPMENT CAN BE USED SAFELY
AND EFFICIENTLY DURING SEEDBED PREPARATION, SEEDING, MULCHING
AND MAINTENANCE OF THE VEGETATION.
3. CONCENTRATIONS OF WATER THAT WILL CAUSE EXCESSIVE SOIL EROSION
SHALL BE DIVERTED TO A SAFE OUTLET. DIVERSIONS AND OTHER
TREATMENT PRACTICES SHALL CONFORM WITH THE APPROPRIATE
STANDARDS AND SPECIFICATIONS
LIME AND FERTILIZER RATES
1. AGRICULTURAL LIME IS REQUIRED AT THE RATE OF ONE TO TWO TONS
PER ACRE UNLESS SOIL TESTS INDICATE OTHERWISE. ALL GRADED AREAS
REQUIRE LIME APPLICATION UNLESS SOIL TEST INDICATE OTHERWISE. IF
LIME IS APPLIED WITHIN SIX MONTHS OF PLANTING PERMANENT
PERENNIAL VEGETATION, ADDITIONAL LIME IS NOT REQUIRED.
AGRICULTURAL LIME SHALL BE WITHIN THE SPECIFICATIONS OF THE
GEORGIA DEPARTMENT OF AGRICULTURE.
2. AGRICULTURAL LIME IS GENERALLY NOT REQUIRED WHERE ONLY TREES
AND SOME LANDSCAPING IS PLANTED, REFER TO TREE PROTECTION AND
LANDSCAPE PLANS FOR LIME REQUIREMENTS IN AREAS OF TREES AND
SHRUBS.
3. REFER TO THE TABLE ON THIS SHEET OR TABLE 6-5.1 OF THE MANUAL FOR
EROSION & SEDIMENT CONTROL IN GA, SIXTH EDITION, FOR FERTILIZER
REQUIREMENTS BY PLANTING SPECIES.
LIME AND FERTILIZER APPLICATION
1. WHEN HYDRAULIC SEEDING EQUIPMENT IS USED, THE INITIAL FERTILIZER
SHALL BE MIXED WITH SEED, INNOCULANT (IF NEEDED), AND WOOD
CELLULOSE OR WOOD PULP FI BER MULCH AND APPLIED IN A SLURRY. THE
INNOCULANT, IF NEEDED, SHALL BE MIXED WITH THE SEED PRIOR TO
BEING PLACED INTO THE HYDRAULIC SEEDER. THE SLURRY MIXTURE WILL
BE AGITATED DURING APPLICATION TO KEEP THE INGREDIENTS
THOROUGHLY MIXED. THE MIXTURE WILL BE SPREAD UNIFORMLY OVER
THE AREA WITHIN ONE HOUR AFTER BEING PLACED IN THE HYDROSEEDER.
2. FINELY GROUND LIMESTONE CAN BE APPLIED IN THE MULCH SLURRY OR IN
COMBINATION WITH THE TOP DRESSING.
3. WHEN CONVENTIONAL PLANTING IS TO BE DONE, LIME AND FERTILIZER
SHALL BE APPLIED UNIFORMLY IN ONE OF THE FOLLOWING WAYS:
a. APPLY BEFORE LAND PREPARATION SO THAT IT WILL BE MIXED
WITH THE SOIL DURING SEEDBED PREPARATION.
b. MIX WITH THE SOIL USED TO FILL THE HOLES, DISTRIBUTE IN
FURROWS.
c. BROADCAST AFTER STEEP SURFACES ARE SCARIFIED, PITTED OR
TRENCHED.
d. A FERTILIZER PELLET SHALL BE PLACED AT ROOT DEPTH IN THE
CLOSING HOLE BESIDE EACH PINE TREE SEEDLING.
PLANT SELECTION
1. PLANT AND LANDSCAPE SPECIES TO BE AS INDICATED ON THE TREE
REPLACEMENT PLAN AND LANDSCAPE PLANS. IN THE EVENT NO SUCH
PLAN HAS BEEN PREPARED, AND SPECIES IS NOT CALLED OUT
SPECIFICALLY ON THE PERMANENT VEGETATION PLAN, SPECIES ARE TO
BE SELECTED BASED ON THE TABLES SHOWN ON THIS SHEET OR FROM
TABLES 6-4.1, 6-5.2, 6-5.3, OR 6.5-4 OF THE MANUAL FOR EROSION &
SEDIMENT CONTROL IN GEORGIA, SIXTH EDITION, AND APPROVED IN
WRITING BY THE OWNER.
RYEGRASS SHALL NOT BE USED IN ANY SEEDING MIXTURES
CONTAINING PERENNIAL SPECIES DUE TO ITS ABILITY TO
OUT-COMPETE DESIRED SPECIES CHOSEN FOR PERMANENT
PERENNIAL COVER.
SEEDBED PREPARATION
SEEDBED PREPARATION MAY NOT BE REQUIRED WHERE HYDRAULIC
SEEDING AND FERTILIZING EQUIPMENT IS TO BE USED (BUT IS STRONGLY
RECOMMENDED FOR ANY SEEDING PROCESS, WHEN POSSIBLE). WHEN
CONVENTIONAL SEEDING IS TO BE USED, SEEDBED PREPARATION WILL BE
DONE AS FOLLOWS:
BROADCAST PLANTINGS
1. TILLAGE, AT A MINIMUM, SHALL ADEQUATELY LOOSEN THE SOIL TO A
DEPTH OF 4 TO 6 INCHES; ALLEVIATE COMPACTION; INCORPORATE LIME
AND FERTILIZER; SMOOTH AND FI RM THE SOIL; ALLOW FOR THE PROPER
PLACEMENT OF SEED, SPRIGS, OR PLANTS; AND ALLOW FOR THE
ANCHORING OF STRAW OR HAY MULCH IF A DISK IS TO BE USED.
2. TILLAGE MAY BE DONE WITH ANY SUITABLE EQUIPMENT.
3. TILLAGE SHOULD BE DONE ON THE CONTOUR WHERE FEASIBLE.
4. ON SLOPES TOO STEEP FOR THE SAFE OPERATION OF TILLAGE
EQUIPMENT, THE SOIL SURFACE SHALL BE PITTED OR TRENCHED ACROSS
THE SLOPE WITH APPROPRIATE HAND TOOLS TO PROVIDE TWO PLACES 6
TO 8 INCHES APART IN WHICH SEED MAY LODGE AND GERMINATE.
HYDRAULIC SEEDING MAY ALSO BE USED.
INDIVIDUAL PLANTS
1. ALL INDIVIDUAL PLANTINGS SHOULD BE PERFORMED IN ACCORDANCE
WITH LANDSCAPE OR TREE REPLACEMENT PLANS.
INOCULANTS
1. ALL LEGUME SEED SHALL BE INOCULATED WITH APPROPRIATE
NITROGEN-FIXING BACTERIA. THE INOCULANT SHALL BE A PURE CULTURE
PREPARED SPECIFICALLY FOR THE SEED SPECIES AND USED WITHIN THE
DATES ON THE CONTAINER.
2. A MIXING MEDIUM RECOMMENDED BY THE MANUFACTURER SHALL BE
USED TO BOND THE INOCULANT TO THE SEED. FOR CONVENTIONAL
SEEDING, USE TWICE THE AMOUNT OF INOCULANT RECOMMENDED BY THE
MANUFACTURER. FOR HYDRAULIC SEEDING, FOUR TIMES THE AMOUNT OF
INOCULANT RECOMMENDED BY THE MANUFACTURER SHALL BE USED.
3. ALL INOCULATED SEED SHALL BE PROTECTED FROM THE SUN AND HIGH
TEMPERATURES AND SHALL BE PLANTED THE SAME DAY INOCULATED. NO
INOCULATED SEED SHALL REMAIN IN THE HYDROSEEDER LONGER THAN
ONE HOUR.
PLANTING
HYDRAULIC SEEDING
MIX THE SEED (INOCULATED IF NEEDED), FERTILIZER, AND WOOD
CELLULOSE OR WOOD PULP FIBER MULCH WITH WATER AND APPLY IN A
SLURRY UNIFORMLY OVER THE AREA TO BE TREATED. APPLY WITHIN ONE
HOUR AFTER THE MIXTURE IS MADE.
CONVENTIONAL SEEDING
SEEDING WILL BE DONE ON A FRESHLY PREPARED AND FIRMED SEEDBED.
FOR BROADCAST PLANTING, USE A CULTIPACKER-SEEDER, DRILL, ROTARY
SEEDER, OTHER MECHANICAL SEEDER, OR HAND SEEDING TO DISTRIBUTE
THE SEED UNIFORMLY OVER THE AREA TO BE TREATED. COVER THE SEED
LIGHTLY WITH 1/8 TO 1/4 INCH OF SOIL FOR SMALL SEED AND 1/2 TO 1 INCH
FOR LARGE SEED WHEN USING A CULTIPACKER OR OTHER SUITABLE
EQUIPMENT.
NO-TILL SEEDING
NO-TILL SEEDING IS PERMISSIBLE INTO ANNUAL COVER CROPS WHEN
PLANTING IS DONE FOLLOWING MATURITY OF THE COVER CROP OR IF THE
TEMPORARY COVER STAND IS SPARSE ENOUGH TO ALLOW ADEQUATE
GROWTH OF THE PERMANENT (PERENNIAL) SPECIES. NO-TILL SEEDING
SHALL BE DONE WITH APPROPRIATE NO-TILL SEEDING EQUIPMENT. THE
SEED MUST BE UNIFORMLY DISTRIBUTED AND PLANTED AT THE PROPER
DEPTH.
MULCHING
MULCH IS REQUIRED FOR ALL PERMANENT VEGETATION APPLICATIONS.
MULCH APPLIED TO SEEDED AREAS SHALL ACHIEVE 75% TO 100% SOIL
COVER. PERMANENT MULCH COVER SELECTION WHERE VEGETATION IS
NOT APPLIED SHOULD BE PLACED AS INDICATED ON TREE REPLACEMENT
AND/OR LANDSCAPING PLANS, OR AT THE DIRECTION OR APPROVAL OF
THE OWNER. MULCH SELECTION FOR TEMPORARY COVER OF PERMANENT
VEGETATION SHALL BE BASED ON SELECTION GUIDELINES IN THE "MULCH
REQUIREMENTS FOR PERMANENT STABILIZATION" TABLE ON THIS SHEET.
WOOD CELLULOSE AND WOOD PULP FIBERS SHALL NOT CONTAIN
GERMINATION OR GROWTH INHIBITING FACTORS. THEY SHALL BE EVENLY
DISPERSED WHEN AGITATED IN WATER. THE FI BERS SHALL CONTAIN A
DYE TO ALLOW VISUAL METERING AND AID IN UNIFORM APPLICATION
DURING SEEDING. APPLYING MULCH
APPLYING MULCH
STRAW OR HAY MULCH WILL BE SPREAD UNIFORMLY WITHIN 24 HOURS
AFTER SEEDING AND/OR PLANTING. THE MULCH MAY BE SPREAD BY
BLOWER-TYPE SPREADING EQUIPMENT, OTHER SPREADING EQUIPMENT
OR BY HAND. MULCH SHALL BE APPLIED TO COVER 75% OF THE SOIL
SURFACE..
WOOD CELLULOSE OR WOOD FIBER MULCH SHALL BE APPLIED UNIFORMLY
WITH HYDRAULIC SEEDING EQUIPMENT.
ANCHORING MULCH
ANCHOR STRAW OR HAY MULCH IMMEDIATELY AFTER APPLICATION BY
ONE OF THE FOLLOWING METHODS:
1. HAY AND STRAW MULCH SHALL BE PRESSED INTO THE SOIL IMMEDIATELY
AFTER THE MULCH IS SPREAD. A SPECIAL “PACKER DISK”’ OR DISK
HARROW WITH THE DISKS SET STRAIGHT MAY BE USED. THE DISKS MAY BE
SMOOTH OR SERRATED AND SHOULD BE 20 INCHES OR MORE IN
DIAMETER AND 8 TO 12 INCHES APART. THE EDGES OF THE DISKS SHALL
BE DULL ENOUGH TO PRESS THE MULCH INTO THE GROUND WITHOUT
CUTTING IT, LEAVING MUCH OF IT IN AN ERECT POSITION. MULCH SHALL
NOT BE PLOWED INTO THE SOIL.
2. SYNTHETIC TACKIFIERS, BINDERS OR HYDRAULIC MULCH SPECIFICALLY
DESIGNED TO TACK STRAW, SHALL BE APPLIED IN CONJUNCTION WITH OR
IMMEDIATELY AFTER THE MULCH IS SPREAD. SYNTHETIC TACKIFIERS
SHALL BE MIXED AND APPLIED ACCORDING TO MANUFACTURER’S
SPECIFICATIONS. ALL TACKIFIERS, BINDERS OR HYDRAULIC MULCH
SPECIFICALLY DESIGNED TO TACK STRAW SHOULD BE VERIFIED
NONTOXIC THROUGH EPA 2021.0 TESTING. REFER TO TACKIFIERS-TAC.
3. RYE OR WHEAT CAN BE INCLUDED WITH FALL AND WINTER PLANTINGS TO
STABILIZE THE MULCH. THEY SHALL BE APPLIED AT A RATE OF
ONE-QUARTER TO ONE-HALF BUSHEL PER ACRE.
4. PLASTIC MESH OR NETTING WITH MESH NO LARGER THAN ONE INCH BY
ONE INCH MAY BE NEEDED TO ANCHOR STRAW OR HAY MULCH ON
UNSTABLE SOILS AND CONCENTRATED FLOW AREAS. THESE MATERIALS
SHALL BE INSTALLED AND ANCHORED ACCORDING TO MANUFACTURER’S
SPECIFICATIONS.
BEDDING MATERIAL
MULCH SHALL BE APPLIED TO ORNAMENTAL BEDS, AROUND SHRUBS, AND
ON BARE AREAS ON LAWNS. WHEN BEDDING MATERIALS ARE NOT
SPECIFIED ON THE LANDSCAPE AND/OR TREE REPLACEMENT PLANS, THE
CONTRACTOR SHALL SELECT AND SEEK PRIOR APPROVAL OF THE OWNER
TO PLACE BEDDING MATERIAL SHOWN IN THE "MULCH REQUIREMENTS
FOR PERMANENT STABILIZATION" TABLE ON THIS SHEET.
IRRIGATION
WATER SHALL BE APPLIED AT A RATE NOT CAUSING RUNOFF AND
EROSION.
TOPDRESSING
TOPDRESSING WILL BE APPLIED ON ALL TEMPORARY AND PERMANENT
(PERENNIAL) SPECIES PLANTED ALONE OR IN MIXTURES WITH OTHER
SPECIES. RECOMMENDED RATES OF APPLICATION ARE LISTED ON THIS.
SHEET AND IN TABLE 6-5.1. OF THE MANUAL FOR EROSION AND SEDIMENT
CONTROL IN GA, SIXTH EDITION.
MULCH REQUIREMENTS FOR PERMANENT STABILIZATION
MATERIAL RATE WHERE TO USE
DRY STRAW
2 TONS/ACRE
TEMPORARY COVER IN SEEDED
AREAS
DRY HAY
2-1/2 TONS/ACRE
WOOD CELLULOSE
MULCH OR WOOD
PULP FIBER
500 LB/ACRE
HYDRAULIC APPLICATIONS
(REQUIRES STRAW OR HAY
APPLICATION NOTED ABOVE
FOLLOWING HYDRAULIC SEEDING)
WOOD CELLULOSE OR
WOOD PULP FIBER W/
TACKIFIER
1,0…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.