36C24919R0128-0001004.pdf
PDF 858 KB Posted
- Solicitation number
- 36C24919R0128
About this file
36C24919R0128 0001 Drawings 03-18-262 Structural FCD.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24919R0128-0004001.pdf | ||
| 36C24919R0128-0004000.docx | DOCX document | |
| 36C24919R0128-0003004.pdf | ||
| 36C24919R0128-0003005.pdf | ||
| 36C24919R0128-0003000.docx | DOCX document | |
| 36C24919R0128-0003008.pdf | ||
| 36C24919R0128-0003001.pdf | ||
| 36C24919R0128-0003006.pdf | ||
| 36C24919R0128-0003003.pdf | ||
| 36C24919R0128-0003007.pdf | ||
| 36C24919R0128-0003002.pdf | ||
| 36C24919R0128-0003009.pdf | ||
| 36C24919R0128-0002000.docx | DOCX document | |
| 36C24919R0128-0001005.pdf | ||
| 36C24919R0128-0001002.pdf | ||
| 36C24919R0128-0001008.pdf | ||
| 36C24919R0128-0001000.docx | DOCX document | |
| 36C24919R0128-0001006.pdf | ||
| 36C24919R0128-0001007.pdf | ||
| 36C24919R0128-0001003.pdf | ||
| 36C24919R0128-0001001.pdf | ||
| 36C24919R0128-000.docx | DOCX document | |
| 36C24919R0128-003.pdf | ||
| 36C24919R0128-005.xlsx | XLSX spreadsheet | |
| 36C24919R0128-002.pdf | ||
| 36C24919R0128-001.docx | DOCX document | |
| 36C24919R0128-004.docx | DOCX document |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
Office of
Construction and Facilities
Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
JMW JBM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON ROAD, MURFREESBORO,
TN 37129
05/07/2019
FINAL CONSTRUCTION DOCUMENTS
626-308
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
GENERAL
1. NO PROVISION OF ANY REFERENCED STANDARD SPECIFICATION, MANUAL OR CODE (WHETHER OR NOT
SPECIFICALLY INCORPORATED BY REFERENCE IN THE CONTRACT DOCUMENTS) SHALL BE EFFECTIVE
TO CHANGE THE DUTIES AND RESPONSIBILITIES OF OWNER, CONTRACTOR, DESIGN PROFESSIONAL, SUPPLIER, OR ANY OF THEIR CONSULTANTS, AGENTS, OR EMPLOYEES FROM THOSE SET FORTH IN THE
CONTRACT DOCUMENTS. NOR SHALL IT BE EFFECTIVE TO ASSIGN TO THE DESIGN PROFESSIONAL OF
RECORD OR ANY OF THE DESIGN PROFESSIONAL OF RECORD'S CONSULTANTS, AGENTS, OR
EMPLOYEES ANY DUTY OR AUTHORITY TO SUPERVISE OR DIRECT THE FURNISHING OR PERFORMANCE
OF THE WORK OR ANY DUTY OR AUTHORITY TO UNDERTAKE RESPONSIBILITIES CONTRARY TO THE
PROVISIONS OF THE CONTRACT DOCUMENTS.
2. CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE STRUCTURAL DOCUMENTS
(DRAWINGS AND SPECIFICATIONS), BUT DO NOT INCLUDE SHOP DRAWINGS, VENDOR DRAWINGS, OR
MATERIAL PREPARED AND SUBMITTED BY THE CONTRACTOR.
3. REFERENCE TO STANDARD SPECIFICATIONS OF ANY TECHNICAL SOCIETY, ORGANIZATION, OR
ASSOCIATION OR TO CODES OF LOCAL OR STATE AUTHORITIES, SHALL MEAN THE LATEST STANDARD, CODE, SPECIFICATION OR TENTATIVE SPECIFICATION ADOPTED AT THE DATE OF TAKING BIDS, UNLESS
SPECIFICALLY STATED OTHERWISE.
4. CONTRACT DOCUMENTS SHALL GOVERN IN THE EVENT OF A CONFLICT WITH THE CODE OF PRACTICE
OR SPECIFICATIONS OF ACI, PCI, AISC, SJI OR OTHER STANDARDS. WHERE A CONFLICT OCCURS
WITHIN THE CONTRACT DOCUMENTS, THE STRICTEST REQUIREMENT SHALL GOVERN.
5. MATERIAL, WORKMANSHIP, AND DESIGN SHALL CONFORM TO THE REFERENCED BUILDING CODE.
6. CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS WITH THE ARCHITECTURAL,
MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL DOCUMENTS. DESIGN PROFESSIONAL SHALL BE
NOTIFIED OF ANY DISCREPANCY OR OMISSION. FOR DIMENSIONS NOT SHOWN ON THE STRUCTURAL
DRAWINGS SEE THE ARCHITECTURAL DRAWINGS.
7. CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE
STARTING WORK. DESIGN PROFESSIONAL SHALL BE NOTIFIED OF ANY DISCREPANCY.
8. CONTRACTOR SHALL VERIFY THE STRUCTURALLY SUPPORTED MECHANICAL EQUIPMENT WEIGHTS, OPENING SIZES AND LOCATIONS IDENTIFIED ON THE STRUCTURAL DRAWINGS WITH ARCHITECTURAL
AND MECHANICAL DRAWINGS.
9. CONTRACTOR SHALL VERIFY THAT MISCELLANEOUS FRAMING SHOWN ON THE STRUCTURAL
DRAWINGS FOR MECHANICAL EQUIPMENT, OWNER-FURNISHED ITEMS, PARTITIONS, ETC. IS
CONSISTENT WITH THE REQUIREMENTS OF SUCH ITEMS.
10. CONTRACTOR HAS SOLE RESPONSIBILITY FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES OF CONSTRUCTION.
11. THE STRUCTURE IS STABLE ONLY IN ITS COMPLETED FORM. TEMPORARY SUPPORTS REQUIRED FOR
STABILITY DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION SHALL BE DESIGNED, FURNISHED, AND INSTALLED BY THE CONTRACTOR.
12. CONTRACTOR HAS SOLE RESPONSIBILITY TO COMPLY WITH ALL OSHA REGULATIONS.
13. ELECTRONIC DRAWING FILES WILL NOT BE PROVIDED TO THE CONTRACTOR. REPRODUCTION OF
STRUCTURAL DRAWINGS FOR SHOP DRAWINGS IS NOT PERMITTED.
14. REVIEW OF SUBMITTALS OR SHOP DRAWINGS BY THE DESIGN PROFESSIONAL DOES NOT RELIEVE THE
CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW AND CHECK ALL SUBMITTALS AND SHOP
DRAWINGS BEFORE SUBMITTING TO THE DESIGN PROFESSIONAL. CONTRACTOR REMAINS SOLELY
RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP
DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE
CONTRACT DOCUMENTS.
15. DETAILS LABELED "TYPICAL" ON THE STRUCTURAL DRAWINGS APPLY TO ALL SITUATIONS OCCURRING
ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THE TYPICAL DETAILS UNLESS THOSE
LOCATIONS ARE SPECIFICALLY DETAILED OTHERWISE.
16. STRUCTURAL DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR THE DESIGN OF STEEL STAIRS, HANDRAILS, CURTAIN WALL/WINDOW WALL SYSTEMS, COLD-FORMED METAL FRAMING, OR OTHER
SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHALL BE DESIGNED,
FURNISHED, AND INSTALLED AS REQUIRED BY OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
CODE/DESIGN CRITERIA
1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE FOLLOWING:
§ INTERNATIONAL BUILDING CODE, 2012 EDITION, WITH TENNESEE AMENDMENTS
2. GRAVITY LOADS
2.1 UNIFORM FLOOR LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
§ GENERAL AREAS 100 PSF
§ EQUIPMENT PLATFORM 40 PSF
2.2 UNIFORM ROOF LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
§ ROOF 20 PSF
§ GROUND SNOW LOAD 5 PSF
§ SNOW EXPOSURE COEFFICIENT = 1.0
§ SNOW LOAD IMPORTANCE FACTOR = 1.0
§ THERMAL FACTOR = 1.0
2.3 DEAD LOADS (IN ADDITION TO STRUCTURE SELF-WEIGHT):
DEAD:
§ MISCELLANEOUS 5 PSF
§ CEILING/MEP 15 PSF
ROOF:
§ ROOFING 5 PSF
§ INSULATION 5 PSF
§ MISCELLANEOUS 5 PSF
§ CEILING/MEP 5 PSF
3. WIND LOADS:
§ ULTIMATE DESIGN WIND SPEED, VULT = 115MPH
§ NOMINAL DESIGN WIND SPEED, VASD = 90MPH
§ RISK CATEGORY: II
§ IMPORTANCE FACTOR = 1.0
§ EXPOSURE C
§ INTERNAL PRESSURE COEFFICIENT = ±0.18
SEE COMPONENT AND CLADDING DESIGN WIND PRESSURE DIAGRAM
4. EARTHQUAKE LOADS:
§ SEISMIC IMPORTANCE FACTOR: I = 1.0
§ RISK CATEGORY: II
§ SHORT PERIOD MAPPED SPECTRAL RESPONSE COEFFICIENT, SS = 0.246
§ 1 SECOND PERIOD MAPPED SPECTRAL RESPONSE COEFFICIENT, S1 = 0.124
§ SITE CLASS D
§ SHORT PERIOD DESIGN SPECTRAL RESPONSE COEFFICIENT, SDS = 0.263
§ 1 SECOND PERIOD DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 = 0.195
§ SEISMIC DESIGN CATEGORY: C
§ BASIC SEISMIC-FORCE RESISTING SYSTEM: STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR
SEISMIC RESISTANCE
§ DESIGN BASE SHEAR: 10 KIPS
§ OVER STRENGTH FACTOR, OMEGA = 3
§ SEISMIC RESPONSE COEFFICIENT, CS = 0.087
§ RESPONSE MODIFICATION FACTOR, R = 3
§ ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
5. UNLESS NOTED OTHERWISE CALCULATED INDIVIDUAL MEMBER DEFLECTIONS (IN INCHES) DO NOT
EXCEED THE FOLLOWING:
DEAD LOAD LIVE LOAD DEAD + LIVE LOAD
ROOF MEMBERS: L/360 L/360 L/240
FLOOR MEMBERS: L/360. L/360 L/240
§ WHERE, L = SPAN LENGTH (IN INCHES) BETWEEN SUPPORTS. (FOR CANTILEVERS, L IS TWICE THE
LENGTH OF THE CANTILEVER.) NOTE THAT THE TOTAL MAXIMUM CALCULATED FLOOR SYSTEM
DEFECTION WILL BE THE SUM OF THE DEFLECTIONS OF THE SUPPORTED ELEMENTS IN A BAY.
6. SPECIAL INSPECTIONS:
6.1 THE STRUCTURAL TESTING/INSPECTION AGENCY WILL PERFORM SPECIAL INSPECTIONS AS
REQUIRED BY CHAPTER 17 OF THE BUILDING CODE. MATERIALS AND WORK TO BE INSPECTED
INCLUDE SOIL, CONCRETE, AND STEEL CONSTRUCTION. SEE SPECIFICATIONS.
6.2 SPECIAL INSPECTION AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE ARE REQUIRED FOR
STRUCTURAL COMPONENTS AND ASSEMBLIES WHICH ARE NOT FABRICATED AT THE CONSTRUCTION
JOB SITE INCLUDING BUT NOT LIMITED TO JOISTS OF STEEL MATERIALS, STRUCTURAL STEEL
FRAMING, AND CLADDING.
6.3 SPECIAL INSPECTION AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE MAY BE WAIVED FOR
ITEMS WHICH ARE PRODUCED ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED TO
PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. APPROVAL SHALL BE BASED UPON REVIEW
OF THE FABRICATOR'S WRITTEN PROCEDURAL AND QUALITY CONTROL MANUALS AND BY PERIODIC
AUDITING OF FABRICATION PRACTICES BY AN APPROVED SPECIAL INSPECTION AGENCY. THE
APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE CHIEF COMMERCIAL
BUILDING INSPECTOR OR HIS DESIGNEE WHICH STATES THAT THE FABRICATION WORK WAS
PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS.
6.4 THE PROJECT OWNER WILL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PERFORM INSPECTIONS
AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE DURING CONSTRUCTION OF THE PROJECT.
DOCUMENTATION THAT SUMMARIZES THE QUALIFICATION AND CREDENTIALS OF EACH SPECIAL
INSPECTOR AND DEMONSTRATES COMPETENCE FOR INSPECTION OF EACH PARTICULAR TYPE OF
CONSTRUCTION REQUIRING SPECIAL INSPECTION SHALL BE SUBMITTED TO THE CHIEF COMMERCIAL
BUILDING INSPECTOR OR HIS DESIGNEE FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION.
6.5 APPROVED SPECIAL INSPECTORS SHALL FURNISH INSPECTION REPORTS TO THE CHIEF COMMERCIAL
BUILDING INSPECTOR OR HIS DESIGNEE AND TO THE DESIGN PROFESSIONAL WHICH INDICATE THAT
THE WORK INSPECTED WAS DONE IN CONFORMANCE WITH THE APPROVED CONSTRUCTION
DOCUMENTS. A FINAL REPORT WHICH DOCUMENTS THE RESULTS OF THE SPECIAL INSPECTIONS
PERFORMED INCLUDING CORRECTION OF ANY DISCREPANCIES IDENTIFIED DURING INSPECTION
SHALL BE SUBMITTED PERIODICALLY AT A FREQUENCY APPROVED BY CHIEF COMMERCIAL BUILDING
INSPECTOR PRIOR TO CONSTRUCTION.
7. NO PROVISIONS HAVE BEEN MADE FOR FUTURE HORIZONTAL OR VERTICAL EXPANSION
FOUNDATION
1. FOUNDATION DESIGN IS BASED ON THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT
PREPARED BY TERRACON CONSULTANTS, REPORT NUMBER 18185203 DATED DECEMBER 24, 2018.
DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS ENCOUNTERED IN THE
FIELD DIFFERENT TO THOSE ASSUMED FOR DESIGN.
2. STRUCTURAL TESTING/INSPECTION AGENCY SHALL CERTIFY THE BEARING MEDIUM.
3. INDIVIDUAL SPREAD FOOTINGS AND CONTINUOUS FOOTINGS SHALL BEAR ON SOIL CAPABLE OF
SUPPORTING 2,500 PSF.
3.1 NO FOOTINGS SHALL BEAR ON ROCK. UNDERCUT ROCK A MINIMUM OF 2 FEET BELOW BOTTOM OF
FOOTING AND REPLACE WITH STRUCTURAL FILL.
4. UNDERCUT THE ENTIRE BUILDING AREA TO A MINIMUM OF 2'-0" BELOW FINISHED FLOOR ELEVATION
AND REPLACE WITH COMPACTED STRUCTURAL FILL AS REQUIRED BY THE SPECIFICATIONS.
ADDITIONAL UNDERCUTTING UP TO 4'-0" MAY BE REQUIRED AT FOUNDATION LOCATIONS WHERE
EXISTING FILL IS ENCOUNTED.
5. PROOF ROLL BUILDING AREAS WITH TWO COMPLETE COVERAGES OF A LOADED DUMP-TRUCK OR
SCRAPER. REPLACE SOFT AREAS WITH COMPACTED STRUCTURAL FILL AS REQUIRED BY THE
SPECIFICATIONS.
6. STRUCTURAL FILL SHALL CONTAIN NO ORGANIC MATERIAL AND BE APPROVED BY A GEOTECHNICAL
ENGINEER PRIOR TO PLACEMENT. STRUCTURAL FILL UNDER SLABS AND WITHIN 10'-0" OF THE
BUILDING FOOTPRINT SHALL BE PLACED IN LIFTS OF THICKNESS DETERMINED BY THE INDEPENDENT
TESTING AGENCY AND COMPACTED TO AT LEAST 95% OF ITS STANDARD PROCTOR MAXIMUM DRY
DENSITY IN ACCORDANCE WITH ASTM D698. THE TOP 12" SUB-BASE UNDER SLABS ON GRADE SHALL
BE COMPACTED TO AT LEAST 98% OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY. ALL BACKFILL, COMPACTION AND PROOF ROLLING OPERATIONS SHALL BE OBSERVED BY AN INDEPENDENT TESTING
LABORATORY.
7. SLABS-ON-GRADE SHALL BE PLACED ON A 4" GRANULAR BASE, COMPACTED TO 98% OF ITS STANDARD
PROCTOR MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698, AND COVERED WITH A
CONTINUOUSLY SEALED VAPOR BARRIER PER ARCH. THE BASE FOR SLABS-ON-GRADE SHALL BE
INSPECTED BY A GEOTECHNICAL ENGINEER PRIOR TO EACH PLACEMENT OF CONCRETE.
8. FOOTINGS SHALL BE CENTERED ABOUT COLUMN LINES UNLESS NOTED OTHERWISE.
9. ALL FOOTINGS AND TURN DOWN SLAB EDGES SHALL PENETRATE TO A MINIMUM DEPTH OF 1'-6" BELOW
FINISHED GRADE.
REINFORCEMENT
1. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE.
2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND HAVE MINIMUM SIDE AND END LAPS OF 8".
3. SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE REINFORCING BAR SIZES AND PLACEMENT.
WRITTEN DESCRIPTION OF REINFORCEMENT WITHOUT ADEQUATE SECTIONS, ELEVATIONS, AND
DETAILS IS NOT ACCEPTABLE.
4. SPLICES SHALL BE CLASS B IN ACCORDANCE WITH ACI 318, UNLESS NOTED OTHERWISE.
REINFORCEMENT SHALL BE SPLICED ONLY AT LOCATIONS SHOWN OR NOTED IN THE STRUCTURAL
DOCUMENTS, EXCEPT REINFORCEMENT MARKED "CONTINUOUS" CAN BE SPLICED AT LOCATIONS
DETERMINED BY CONTRACTOR. SPLICES AT OTHER LOCATIONS SHALL BE APPROVED IN WRITING BY
THE DESIGN PROFESSIONAL.
5. REINFORCING STEEL DESIGNATED CONTINUOUS SHALL BE LAPPED AS FOLLOWS:
§ CONCRETE REINFORCEMENT: CLASS B TENSION LAP
6. PROVIDE DOWELS FROM FOUNDATIONS THE SAME SIZE AND NUMBER AS THE VERTICAL WALL OR
PEDESTAL REINFORCING, UNLESS NOTED OTHERWISE.
7. PLACE REINFORCEMENT AS FOLLOWS, UNLESS NOTED OTHERWISE:
7.1 CONCRETE REINFORCEMENT COVER
EXPOSED TO EARTH OR WEATHER:
§ UNFORMED CAST AGAINST EARTH 3” CLEAR
§ FORMED #6 AND LARGER 2” CLEAR
§ FORMED #5 AND SMALLER 1-1/2” CLEAR
NOT EXPOSED TO EARTH OR WEATHER:
§ SLABS 3/4" CLEAR
8. ADHESIVE FOR REINFORCING DOWELS IN EXISTING CONCRETE SHALL CONFORM TO ASTM C881-02, TYPE IV, GRADE 3, CLASS A, B, & C EXCEPT GEL TIMES AND EPOXY CONTENT. ADHESIVE SHALL
CONSIST OF A TWO COMPONENT ADHESIVE SYSTEM CONTAINED IN SIDE BY SIDE PACKAGING
CONNECTEED TO A MIXING NOZZLE WHICH THOROUGHLY MIXES THE COMPONENTS AS IT IS INJECTED
INTO THE HOLE. ADHESIVE SHALL HAVE PASSED ICC EVALUATION SERVICES, INC (ICC-ES) ACCEPTANCE
CRITERIA 308 FOR LONG TERM CREEP. REINFORCING INSTALLED IN CONCRETE THAT MAY BECOME
CRACKED UNDER SERVICE LOADS SHALL BE EVALUATED BY ICC-ES ACCEPTANCE CRITERIA 308 AND BE
SPECIFICALLY APPROVED FOR USE IN CRACKED CONCRETE. CONTACT DESIGN PROFESSIONAL FOR
DETERMINATION OF CRACKED OR UNCRACKED CONCRETE CONDITION UNLESS CONDITION IS NOTED
ON THE DRAWINGS. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
MINIMUM EMBEDMENT LENGTH SHALL BE 12 BAR DIAMETERS, UNLESS NOTED OTHERWISE.
9. ALL DOWELS AND TERMINATING BARS SHALL HAVE A STANDARD 90 DEGREE HOOK.
10. ALL HORIZONTAL REINFORCING SHALL BE CONTINUOUS THROUGH CONTROL AND/OR CONSTRUCTION
JOINTS AND AROUND CORNERS.
CAST-IN-PLACE CONCRETE
1. CONCRETE WORK SHALL CONFORM TO ACI 318 AND CRSI STANDARDS.
2. CONCRETE SHALL HAVE THE FOLLOWING MINIMUM SPECIFIED 28-DAY COMPRESSIVE STRENGTH:
2.1 NORMAL WEIGHT STRUCTURAL CONCRETE:
§ FOOTINGS 3000 PSI
§ SLABS-ON-GRADE 4000 PSI
2.2 LIGHTWEIGHT STRUCTURAL CONCRETE:
(110-120 PCF FRESH UNIT WEIGHT/107-116 PCF AIR-DRIED UNIT WEIGHT)
(USE 113 PCF AS UPPER LIMIT FOR 3-HR, 6-1/4" SLAB)
§ SLABS ON COMPOSITE STEEL DECK 3500 PSI
3. PIPES OR DUCTS SHALL NOT EXCEED ONE-THIRD THE SLAB OR WALL THICKNESS INCLUDING CROSSING
UNLESS SPECIFICALLY DETAILED IN THE STRUCTURAL DOCUMENTS. ALL PIPES AND DUCTS SHALL BE
PLACED IN THE MIDDLE THIRD OF THE SLAB OR WALL THICKNESS UNLESS SPECIFICALLY DETAILED
OTHERWISE IN THE STRUCTURAL DOCUMENTS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
LOCATION OF SLEEVES, ACCESSORIES, ETC.
4. REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, CLIPS OR GROUNDS
REQUIRED TO BE ENCASED IN CONCRETE AND FOR LOCATION OF FLOOR FINISHES AND SLAB
DEPRESSIONS.
5. CONSTRUCTION JOINT LOCATIONS SHALL BE APPROVED BY THE DESIGN PROFESSIONAL. NO
HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED EXCEPT THOSE SHOWN ON THE STRUCTURAL
DRAWINGS.
6. DEFECTIVE AREAS IN CONCRETE INCLUDING, BUT NOT LIMITED TO, HONEY-COMBING, SPALLS, AND
CRACKS WITH WIDTHS EXCEEDING 0.016 INCH SHALL BE REPAIRED. EXTENT OF DEFECTIVE AREA TO BE
DETERMINED BY THE DESIGN PROFESSIONAL.
7. CONCRETE MIX DESIGN FOR 3000 PSI CONCRETE SHALL BE BASED ON A MAXIMUM AGGREGATE SIZE
OF 1 IN. MAXIMUM WATER/CEMENT RATIO OF .58 FOR NON-AIR-ENTRAINED CONCRETE AND .46 FOR
AIR-ENTRAINED CONCRETE AND A MAXIMUM SLUMP OF 4 IN. AIR ENTRAINED CONCRETE SHALL BE
USED FOR EXTERIOR EXPOSED CONCRETE WITH AN AIR CONTENT BETWEEN 5.5 AND 7.5 PERCENT.
8. CONCRETE SLABS ON GRADE SHALL NOT BE LOADED UNTIL A MINIMUM CONCRETE STRENGTH OF 1800
PSI HAS BEEN ATTAINED AND THE CONCRETE IS AT LEAST THREE DAYS OLD. ALL OTHER CONCRETE
MEMBERS SHALL NOT BE LOADED UNTIL THE SPECIFIED CONCRETE DESIGN STRENGTH HAS BEEN
ATTAINED.
9. CONCRETE SHALL BE TESTED IN ACCORDANCE WITH ACI 301 AND THE SPECIFICATIONS FOR
COMPLIANCE WITH THE CONTRACT DOCUMENTS. AT A MINIMUM CONCRETE SPECIMENS SHALL BE
TAKEN FOR EVERY 100 YARDS OR PORTION THEREOF FOR EACH MIX DESIGN PLACED IN A DAY.
CONCRETE TEST REPORTS SHALL BE AVAILABLE ON SITE FOR INSPECTION.
10. C.J. ON THE SLAB AND FOUNDATION PLAN INDICATES A KEY-FORMED CONSTRUCTION JOINT OR
SAW-CUT CONTROL JOINT IN THE CONCRETE SLAB ON GRADE. SAW-CUT CONTROL JOINTS SHALL BE
INSTALLED WITHIN 12 HOURS OF SLAB PLACEMENT. CONTINUE REINFORCEMENT THROUGH JOINTS.
CONSTRUCTION AND/OR CONTROL JOINTS SHALL BE SPACED NO FARTHER APART THAN 48 TIMES THE
SLAB THICKNESS O.C IN EACH DIRECTION CREATING PANELS WITH AN ASPECT RATIO NOT GREATER
THAN 2:1.
11. UNLESS NOTED OTHERWISE, ALL REINFORCING SHALL BE CONTACT LAP SPLICED WITH A CLASS B
SPLICE IN ACCORDANCE WITH ACI 318. FOR BARS WITH MINIMUM COVER AND SPACING GREATER THAN
2db AND 3db RESPECTIVELY, THE MINIMUM SPLICE LENGTH OF NOT LESS THAN 48db (db=BAR
DIAMETER) SHALL BE USED. SPLICE LENGTHS SHALL BE INCREASED BY A FACTOR OF 1.3 FOR TOP
REINFORCEMENT. LAP WELDED WIRE FABRIC (WWF) ONE SPACE PLUS 2 IN. ON ALL SIDES AT SPLICES.
STRUCTURAL STEEL
1. STRUCTURAL STEEL SHALL CONFORM TO ASTM A992, UNLESS NOTED OTHERWISE.
§ STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B.
§ STRUCTURAL STEEL PIPE SHALL CONFORM TO ASTM A53, GRADE B.
§ STRUCTURAL CHANNELS, MISCELLANEOUS PLATES AND CONNECTION MATERIAL SHALL CONFORM TO
ASTM A36, UNLESS NOTED OTHERWISE.
2. BOLTS AND ANCHORS:
2.1 BOLTED CONNECTIONS SHALL BE TYPE N (BEARING TYPE WITH THREADS INCLUDED IN SHEAR PLANE)
WITH MINIMUM 3/4" DIAMETER (UNO) A325 BOLTS. SUBMIT PROPOSED BOLT TIGHTENING PROCEDURE
FOR REVIEW.
2.2 ANCHOR BOLTS SHALL BE HEADED BOLTS CONFORMING TO ASTM F1554 AND SHALL BE HEADED RODS
OR THREADED RODS WITH HEAVY HEXAGONAL NUT WELDED TO THE BOTTOM OF THE THREADED
ROD, GRADE A36, UNLESS NOTED OTHERWISE.
2.3 EXPANSION ANCHORS SHALL HAVE BEEN EVALUATED BY THE ICC EVALUATION SERVICES, INC
(ICC-ES) WITH A PUBLISHED EVALUATION REPORT. ANCHORS INSTALLED IN CONCRETE THAT MAY
BECOME CRACKED UNDER SERVICE LOADS SHALL BE EVALUATED BY ICC-ES ACCEPTANCE CRITERIA
193 AND BE SPECIFICALLY APPROVED FOR USE IN CRACKED CONCRETE. CONTACT DESIGN
PROFESSIONAL FOR DETERMINATION OF CRACKED OR UNCRACKED CONCRETE CONDITION UNLESS
CONDITION IS NOTED ON THE DRAWINGS. ALL ANCHORS SHALL BE APPROVED FOR RESISTING WIND
AND SEISMIC LOADS. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
MINIMUM EMBEDMENT SHALL BE EQUAL TO 4.5 TIMES THE ANCHOR DIAMETER, UNLESS NOTED
OTHERWISE.
2.4 ADHESIVE ANCHORS SHALL CONSIST OF AN ALL-THREAD STEEL ANCHOR WITH ADHESIVE
CONFORMING TO ASTM C881-02, TYPE IV, GRADE 3, CLASS A, B, & C EXCEPT GEL TIMES AND EPOXY
CONTENT. ADHESIVE SHALL CONSIST OF A TWO COMPONENT ADHESIVE SYSTEM CONTAINED IN SIDE
BY SIDE PACKAGING CONNECTED TO A MIXING NOZZLE WHICH THOROUGHLY MIXES THE
COMPONENTS AS IT IS INJECTED INTO THE HOLE. ADHESIVE SHALL HAVE PASSED ICC EVALUATION
SERVICES, INC (ICC-ES) ACCEPTANCE CRITERIA 308 FOR LONG TERM CREEP. ANCHORS INSTALLED IN
CONCRETE THAT MAY BECOME CRACKED UNDER SERVICE LOADS SHALL BE EVALUATED BY ICC-ES
ACCEPTANCE CRITERIA 308 AND BE SPECIFICALLY APPROVED FOR USE IN CRACKED CONCRETE.
CONTACT DESIGN PROFESSIONAL FOR DETERMINATION OF CRACKED OR UNCRACKED CONCRETE
CONDITION UNLESS CONDITION IS NOTED ON THE DRAWINGS. INSTALL IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE EQUAL TO 4.5 TIMES THE
ANCHOR DIAMETER, UNLESS NOTED OTHERWISE.
3. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED ACCORDING TO BOTH THE AISC
“SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” AND THE AISC "CODE OF STANDARD PRACTICE
FOR STEEL BUILDINGS AND BRIDGES".
4. SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE STRUCTURAL ELEMENTS AND
CONNECTIONS SHOWN IN THE CONTRACT DOCUMENTS. CONNECTIONS SHALL BE DETAILED BASED ON
THE DESIGN INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS. CONNECTIONS SHALL BE
DESIGNED FOR THE SERVICE LOAD REACTION VALUES SHOWN ON THE STRUCTURAL DRAWINGS. FOR
STEEL MEMBERS WHOSE REACTIONS ARE NOT SHOWN, THE DESIGN REACTION SHALL BE OBTAINED
FROM THE TABLES ENTITLED "MAXIMUM TOTAL UNIFORM LOAD" IN PART 3 OF THE AISC "MANUAL OF
STEEL CONSTRUCTION", FOURTEENTH (14TH) EDITION. THE DESIGN REACTION IS EQUAL TO HALF THE
TABULATED VALUE FOR NONCOMPOSITE BEAMS. DEVIATION FROM THE CONNECTION DETAILS
DEPICTED IN THE CONTRACT DOCUMENTS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION
FROM THE DESIGN PROFESSIONAL. REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE FULL
RESPONSIBILITY FOR THE DESIGN AND ADEQUACY OF SUCH CONNECTIONS. SINGLE ANGLE
CONNECTIONS ARE NOT ACCEPTABLE.
5. USE PRE-QUALIFIED WELDED JOINTS IN ACCORDANCE WITH AISC AND THE STRUCTURAL WELDING
CODE OF THE AMERICAN WELDING SOCIETY. "NON-PRE-QUALIFIED JOINTS" SHALL BE QUALIFIED PRIOR
TO FABRICATION.
6. STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED.
STEEL JOISTS
1. STEEL JOISTS, BRIDGING, AND THEIR CONNECTIONS SHALL BE DESIGNED, FABRICATED, AND ERECTED
ACCORDING TO THE SPECIFICATIONS OF THE STEEL JOIST INSTITUTE (SJI).
2. STEEL ROOF JOISTS AND BRIDGING SHALL BE DESIGNED FOR A NOMINAL NET UNIFORM UPLIFT LOAD
OF 10 PSF.
3. BRIDGING SHALL BE DESIGNED TO FULLY BRACE TOP CHORD OF JOISTS UNDER SERVICE LOADS FOR
ROOF JOISTS NOT BRACED BY STEEL ROOF DECK.
4. DESIGN OF STEEL JOISTS, BRIDGING, AND THEIR CONNECTIONS SHALL BE THE SOLE RESPONSIBILITY
OF THE CONTRACTOR. SUBMIT SHOP DRAWINGS SEALED BY AN ENGINEER LICENSED IN THE PROJECT
STATE. REVIEW OF SHOP DRAWINGS SHALL BE FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS
REGARDING ARRANGEMENT AND SIZES OF MEMBERS AND THE CONTRACTOR'S INTERPRETATION OF
THE DESIGN LOADS AND CONTRACT DOCUMENT DETAILS. SUCH REVIEW SHALL NOT RELIEVE THE
CONTRACTOR OF FULL RESPONSIBILITY FOR THE DESIGN OF THE STEEL JOISTS, BRIDGING AND THEIR
CONNECTIONS.
5. CONTRACTOR SHALL COORDINATE THE CONSTRUCTION AND ERECTION OF WALLS, BEAM FRAMING, METAL DECKING, ETC. TO ENSURE COMPATIBILITY OF ROOF AND WALL SYSTEMS CONSIDERING PITCH
AND CAMBER OF STEEL JOISTS.
METAL DECK
1. DECK DESIGN IS BASED ON THE STEEL DECK INSTITUTE DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS.
2. PROVIDE COMPOSITE DECK WITH THE FOLLOWING MINIMUM PROPERTIES:
§ 1 1/2 INCH DEPTH
§ 18 GAGE THICKNESS
§ 0.311IN3/FT SECTION MODULUS
§ 0.272 IN4/FT MOMENT OF INERTIA
§ 33,000 PSI YIELD STRESS
4. DECK IS SPECIFIED BASED ON A THREE SPAN CONDITION. FURNISH HEAVIER GAGE DECK IF REQUIRED
FOR ONE OR TWO SPAN CONDITIONS.
5. FASTEN ROOF DECK TO RESIST A NOMINAL NET UPLIFT OF 21 PSF INNER ZONE AND 35 PSF PERIMETER
OR AS INDICATED ON THE DRAWINGS.
6. FASTEN DECK TO RESIST A DIAPHRAGM NOMINAL SHEAR FORCE OF 139 POUNDS PER LINEAR FOOT.
COMPOSITE FLOOR CONSTRUCTION
1. COMPOSITE FLOOR MEMBERS ARE DESIGNED TO BE UNSHORED UNLESS NOTED OTHERWISE.
2. COMPOSITE FLOOR SLABS ARE TO BE FINISHED LEVEL. THE WEIGHT OF THE WET CONCRETE WILL
CAUSE DEFLECTIONS OF THE STEEL FRAMING AND DECKING. THUS, CONCRETE OVERRUNS ARE TO BE
ANTICIPATED AND INCLUDED IN THE CONTRACTOR'S BASE BID.
4. COORDINATE EMBEDDED ITEMS REQUIRED FOR ARCHITECTURAL, STRUCTURAL, AND MECHANICAL
ELEMENTS. OBTAIN WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER FOR PLACEMENT OF
EMBEDDED ITEMS, RECESSES OR DEPRESSIONS IN THE SLAB NOT SHOWN ON THE STRUCTURAL
DOCUMENTS.
5. CONDUIT, PIPE, OR DUCT CAST WITHIN COMPOSITE SLAB SHALL NOT EXCEED 1 INCH IN OUTSIDE
DIAMETER NOR ONE THIRD THE CONCRETE COVER THICKNESS, SHALL BE PLACED WITHOUT
CROSSOVERS, SHALL HAVE AT LEAST 3/4 INCH OF CONCRETE COVER AND SHALL BE PLACED AT LEAST
19 INCHES APART UNLESS SPECIFICALLY DETAILED AND SHOWN IN STRUCTURAL DOCUMENTS. THE
STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE EFFECT OF CONDUIT, PIPE, OR
DUCT NOT SPECIFICALLY SHOWN IN THE STRUCTURAL DOCUMENTS ON THE FULFILLMENT OF
GOVERNING CODE REQUIREMENTS AND SPECIFIED FIRE RATINGS BY THE COMPOSITE SLAB SYSTEM.
6. PLACEMENT OF CONTROL JOINTS IN THE COMPOSITE FLOOR SLAB IS PROHIBITED.
WALL ELEVATION COMPONENTS AND CLADDING
ULTIMATE WIND PRESSURE DIAGRAM
= -22.3 PSF/+20.5 PSF
= --26.5 PSF/+20.5 PSF
NOTE: WIND PRESSURE BASED ON 25 SQUARE FOOT AREA ON
WALL, 10 SQUARE FOOT AREA ON PARAPET. NEGATIVE
INDICATES PRESSURE AWAY FROM SURFACE
= -38.1 PSF/+54.4 PSF
= -43.5 PSF/+74.6 PSF
ROOF PLAN COMPONENTS AND CLADDING
ULTIMATE WIND PRESSURE DIAGRAM
= -22.4 PSF/+16 PSF
= -30.1 PSF/+16 PSF
NOTE: WIND PRESSURE BASED ON 50 SQUARE FOOT AREA ON
ROOF LEVEL. NEGATIVE INDICATES PRESSURE AWAY
FROM SURFACE
= -36.1 PSF/+33 PSF
ELEV
ELEV
ELEV
ELEVATION 1
ELEVATION 2
ELEVATION 3
P A
R A
P E
T
S E
E
A
R C
H
P A
R A
P E
T
S E
E
A
R C
H
P A
R A
P E
T
S E
E
A
R C
H
4'-6" TYP.
4'-6" TYP.
(E) BLDG
4'-6" TYP.
4'-6" TYP.
(E) BLDG
(E) BLDG
GENERAL NOTES
S-001
DocuSign Envelope ID: C8DA48B0-2FEC-4E73-9D94-4A677B2A3FF2
5/7/2019
26 30
E
F
A
1' - 3 1/8"
2' - 7" 7' - 10 1/2" 11' - 8 3/4"
B
D
C
F4.
F4.
F2.
F4.
H
SS4X
4X 1/
H
SS5X
5X 3/
H
SS4X
4X 1/
H
SS5X
5X 1/
H
SS5X
5X 1/
H
SS4X
4X 1/
SLAB ON GRADE
SEE NOTE 5
SEE NOTE 8, TYP
25.5
S-301
S-301
(E) FOOTING
BP1
BP1
BP2
BP3
BP3
S-301
S-301
SLAB ON GRADE
SEE NOTE 5
(E) BUILDING
S-301
EXISTING NEW
TRENCH DRAIN,
SEE ARCH
S-301
R A
M P
S L
O P
E 37
F4.
H
SS4X
4X 1/
S-301
BP1
/8
/4
/2
/8
F6.
F14 .0H
SS5X
5X
3/
H
SS5X
5X 3/
H
SS5X
5X 1/
S-301
BP2
BP2
BP2
BF
B F
G
4' - 6"
F6.
H
SS5X
5X 3/
BP2
BF
EXISTING NEW
F8.
H
SS4X
4X 1/
BP1
F4.
0H
SS5X
5X
1/
S-301
BP2
H
SS
4X4X1/4
F8.0
BP1
5' - 7 1/4" 10' - 8"
BP2
C.J., TYP
SEE NOTE 6
/4
/4
NOTES:
1. SEE S-001 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND DIMENSIONS.
3. Fx INDICATES COLUMN FOOTING. SEE 2/S-301. T/FTG = -1'-4" UNO, BASED ON T/SLAB REFERENCE ELEVATION = 0'-0".
TOP OF SLAB TO BE COORDINATED WITH ADJACENT EXISTING BUILDING.
4. BPx INDICATES COLUMN BASE PLATE. SEE 6 & 10/S-301.
5. PROVIDE 4" SLAB ON GRADE REINFORCED WITH WWF 6x6 W1.4xW1.4 ON VAPOR BARRIER AND 6" GRANULAR BASE.
6. C.J. INDICATES SLAB CONTROL JOINT. SEE 8/S-301 AND GENERAL NOTES FOR ADDITIONAL INFORMATION.
7. ISOLATION JOINT AT COLUMN. SEE 4/S-301.
8. PROVIDE REINFORCEMENT AT RE-ENTRANT CORNERS, SEE 12/S-301.
9. INDICATES BRACED FRAME, SEE S-502.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL UTILITY AND PLUMBING LINES. SEE 15/S-301.
## KEY NOTES:
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT MANAGER:
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/7
/2
:1
:0
A
M
S-101
GROUND FLOOR PLAN
JMW JBM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON RD, MURFREESBORO,
TN 37129
05/07/2019
FINAL CONSTRUCTION DOCUMENTS
626-308
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
1/4" = 1'-0"S-101
1 GROUND FLOOR PLAN
BRACED FRAME
SEE NOTE 9
F
A
B
D
C
W12X19
W
X
S-501
W12X19W12X19
W8X10
W8X10
W X
W
X
W x
W x
W
X
H
SS4X
4X 1/
H
AN
G
ER
ABO
VE
H A
N G
ER
ABO
VEH
SS4X
4X
1/
S-501
S-501
25.5
W8X10
S-501
S-501
(E) BUILDING
/8
/4
/2
/8
0' - 9"
1' - 3 1/8"
2' - 7" 7' - 10 1/2" 11' - 8 3/4"
S-501
S-501
/4
/4
/4
BF
BF
B F
HANDRAIL, SEE ARCH
EXISTING NEW
EXISTING NEW
S-501
@ OPNG
/8
37 40
G W12X19
W12X19
S-501
S-501
W x
W
X
W
X
W
X
W
X
5' - 7 1/4" 10' - 8"
4' - 6"
NOTES:
1. SEE S-001 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND DIMENSIONS.
3. INDICATES DIRECTIONAL SPAN OF 0.6" 22 GA GALV. COMPOSITE FLOOR DECK WITH 2" LIGHT WEIGHT
CONCRETE (TOTAL 2 1/2" DEPTH) AND WWF 6x6 W2.1xW2.1, SEE 3/S-501.
4. DECK BEARING ELEVATION @ 10'-9 1/2" RELATIVE TO FIRST FLOOR REFERENCE ELEVATION = 0'-0" UNO. SEE ARCH.
5. INDICATES BRACED FRAME, SEE S-502.
## KEY NOTES:
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT MANAGER:
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/7
/2
:1
:0
A
M
S-102
FIRST FLOOR - EQUIPMENT PLAN
JMW JBM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON RD, MURFREESBORO,
TN 37129
05/07/2019
FINAL CONSTRUCTION DOCUMENTS
626-308
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
1/4" = 1'-0"S-102
1 FIRST FLOOR - EQUIPMENT PLAN
DN
E
F
A
B
D
C
20K4
20K4
20K4
20K4
10K1
10K1
10K1
20K4
10K1
10K1
10K1
W X
W
X
W14X22
W
X
W16X26 W
X
W
X
W
X
W16X26 W12X19
22K5
22K5
22K5
22K5
22K5
20K4
20K4
20K4
10K1 22K5
W X
S-501
S-501
S-501
S-501
S-501
S-501
W12X19
10K1
H
AN
G
ER
BELO
W
H
AN
G
ER
BELO
W
25.5
S-501
S-501
D E
C K
B R
N G
E L
/4
(E) BUILDING
0' - 4"
0' - 11 1/8"
2' - 7" 7' - 10 1/2" 11' - 8 3/4"
W X
W X
CANT
CANT
S-501
S-501
/8
S-501
/4
/4
/4
EXISTING NEW
37 40
G
W
X
W
X
W
X
D E
C K
B R
N G
E L
/8
/4
/2
/8
S-501
B F
W16X26 W12X19W12X19
CANT
S-501
1' - 1 3/8"
BF
EXISTING NEW
W X
BF
4' - 6"
5' - 7 1/4" 10' - 8"
NOTES:
1. SEE S-001 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND DIMENSIONS.
3. DECK BEARING ELEVATIONS (D.B.E.) SHOWN ARE RELATIVE TO FIRST FLOOR REFERENCE ELEVATION = 0'-0" UNO.
4. INDICATES DIRECTIONAL SPAN OF 1 1/2" 20 GA GALV. COMPOSITE FLOOR DECK WITH 2" LIGHT WEIGHT CONCRETE
(TOTAL 3 1/2" DEPTH) AND WWF 6x6 W1.4xW1.4, SEE 3/S-501.
5. INDICATES BRACED FRAME, SEE S-502.
## KEY NOTES:
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT MANAGER:
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/7
/2
:1
:0
A
M
S-103
ROOF FRAMING PLAN
JMW JBM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON RD, MURFREESBORO,
TN 37129
05/07/2019
FINAL CONSTRUCTION DOCUMENTS
626-308
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
1/4" = 1'-0"S-103
1 ROOF FRAMING PLAN
- A B C D E F NO W
WELDANCHOR BOLTSBASE PLATECOLUMN SIZE
BASE PLATE AND ANCHOR BOLT SCHEDULE
BP1 3/4 10 10 3.5 3/4 9 4 1/4
B
D D
D D
A
F
E
G R
O U
T
M I N
TACK
W
THREADED ANCHOR BOLT
PROJECTION = GROUT + BASE
PLATE THICKNESS + ANCHOR
BOLT DIA + 1" MIN
ANCHOR ROD WITH 2 STD FLAT
WASHERS AND 2 HEAVY HEX
NUTS, TYP
BASE PLATE AND ANCHOR BOLT SCHEDULE
3/4" = 1'-0"
TYPICAL BASE PLATE AND ANCHOR BOLT (TUBE)
3/4" = 1'-0"
FOOTING SCHEDULE
3/4" = 1'-0"
F2.0 2'-0"x2'-0"x1'-0" (2) #5 EW -
REMARKSREINF
SIZE (WxLxT)
MARK
FOOTING SCHEDULE
TYPICAL GRADE SUPPORTED SLAB AT JOINTS
3/4" = 1'-0"
NOTE: SAW CUT OR DISCONTINUE REINF AT
CONTRACTION JT
CONSTRUCTION JOINT
CONTRACTION JOINT
SLAB REINF IN TOP 1/3 OF SLAB
1/8"x1/3 SLAB DEPTH SAW CUT JT
SLAB REINF IN TOP 1/3 OF SLAB
TOOLED JT
TYPICAL REINFORCEMENT AT SLAB RE-ENTRANT
CORNER
3/4" = 1'-0"
BLDG CORNER OR CONSTRUCTION JT
2#5 x 4'-0" TOP
TYPICAL ISOLATION JOINT AT STEEL COLUMN
3/4" = 1'-0"
C L
R
C
L
R
C
L
R
C
L
R
TYPICAL TURNDOWN SLAB ON FOOTING
3/4" = 1'-0"
FIN GR
8"
M I N
8"8"
WWF
#4@12"
3#4 CONT
T/FTG EL
T/SLAB EL
3'-0"
2#5 CONT
TYPICAL GRADE SUPPORTED SLAB AT EXISTING
BUILDING
3/4" = 1'-0"
8"
T/SLAB EL
(E) MASONRY WALL
1/2" EXP JT
1#4 CONT
WWF
TYPICAL THICKENED FOOTING AT UNDERGROUND
PIPING
3/4" = 1'-0"
W A
F
T G
M I N
2'-8"
1'-6" 2'-0"
M I N
G
T H
I C
K N
E S
S
2'-0" 1'-6"
2'-8"
PIPE NEAR TOP OF FOOTING
CL OF PIPE
T/FTG EL
M I N
1'-6" 2'-0"
M
G
T H
I C
K N
E S
S
2'-0" 1'-6"
PIPE AT BOTTOM OF FOOTING
2'-8"2'-8"
PIPE UNDER FOOTING
NOTE:
VERIFY PIPE PENETRATION
LOCATIONS W/ PLUMBING
CONTRACTOR
T/FTG EL
T/FTG EL
M I N
W A
G
W A
L L
F
T G
ADDL REINF TO MATCH
FTG REINF
FTG REINF
ADDL REINF TO
MATCH FTG REINF
FTG REINF
FTG REINF
#6@12"
#6@12"
BASE PLATE
ISOLATION JT
EDGE OF SLAB
CONTRACTION JT
OR CONSTRUCTION
JT, TYP
BASE PLATE
CONTRACTION JT OR
CONSTRUCTION JT,
TYP
ISOLATION JT
EDGE OF SLAB
EDGE OF SLAB
TYPICAL EXTERIOR STEEL COLUMN FOOTING
3/4" = 1'-0"
T/FTG EL
G R
O U
T
SEE 10/S-301 FOR
BASE PLATE AND
ANCHOR BOLT DTL /
SCHED
T/SLAB EL
CL COL / FTG
TYPICAL INTERIOR STEEL COLUMN FOOTING
3/4" = 1'-0"
G R
O U
T
T/SLAB EL
T/FTG EL
CL COL/FTG
ISOLATION JOINT
SEE 10/S-301 FOR
BASE PLATE AND
ANCHOR BOLT DTL /
SCHED
F4.0 4'-0"x4'-0"x1'-0" (4) #5 EW -
F6.0 6'-0"x6'-0"x1'-0" (6) #5 EW -
F8.0 8'-0"x8'-0"x1'-4" (10) #5 EW -
F14.0 14'-0"x4'-0"x1'-0" #5 @ 12" OC EW -
BP2 3/4 12 12 4.5 3/4 9 4 1/4
BP3 3/4 12 12 4.5 3/4 6 NOTE 1 1/4
COLUMN BEARING AT EXISTING FOOTING
3/4" = 1'-0"
T/FTG MATCH
(E) FTG EL
T/SLAB EL
CL COL / FTG
(E) CONC COLUMN
(E) FOOTING
BASE PLATE, SEE 6&10/S-301
COLUMN, SEE PLAN
6"
M
I N
VENEER, SEE ARCH
GROUT SOLID BELOW
GRADE
2#4 CONT
#4 @ 12" O.C., ALTERNATE HOOKS
STUD WALL, SEE ARCH
M
A X
FOOTING EXTENSION
NOTES:
1. PROVIDE 4 ADHESIVE ANCHORS TO EXISTING FOOTING. SEE
GENERAL NOTES FOR ADDITIONAL INFORMATION.
2#4 T&B
#4 ADHESIVE DOWELS
@ 12" O.C., MINIMUM 6"
EMBEDMENT T&B
TYPICAL TURN DOWN SLAB AT DOOR
3/4" = 1'-0"
1'-0"
M I N
1/2" EXP JT
SIDEWALK,
SEE CIVIL
WWF
#4@12"
3'-0"
2#4 CONT
T/SLAB EL
WALLBEYOND,
SEE ARCH
TYPICAL RAMP SECTION
3/4" = 1'-0"
1'-0"
M I N
FIN GRADE EL
VARIES
M A
X
T/RAMP EL
VARIES
6"
2#4 CONT
2#4 CONT
#4 @ 12" O.C.
1'-0"
6"
#4 @12'' CONT
#4 @ 12'' O.C.
SEE NOTE 1
S E
E
N
O T
E
2'-6"
5" MIN
TYP
T/SLAB EL
NOTES:
1. SEE ARCH FOR DRAIN DIMENSIONS AND
INFORMATION.
#4 @ 12" O.C.
TRENCH DRAIN, SEE NOTE 1
TYPICAL TRENCH DRAIN AT EDGE OF SLAB
3/4" = 1'-0"
SLAB REINFORCEMENT,
SEE PLAN
#4 @ 12" O.C.
SEE ARCH
FOUNDATION DETAILS
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
Office of
Construction and Facilities
Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
JMW JBM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON ROAD, MURFREESBORO,
TN 37129
05/07/2019
FINAL CONSTRUCTION DOCUMENTS
626-308
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
S-301
TYP
1/8
CL OF CONCENTRATED LOAD ON ROOF
NOTE 1
CL OF PANEL POINT
NOTE:
1. CONCENETRATED LOAD GREATER THAN 100 LBS BUT NOT TO EXCEED
300 LBS. MAX OF 2 LOADS TOTAL PER JOIST.
CL OF CONCENTRATED
LOAD ON ROOF NOTE 1
CL OF
PANEL
POINT
BAR JOIST
2 L1-1/2 X1-1/2 X3/16 TYP
3/16
1/8
DECK BEARING EL
6"
MIN
1/2" CAP PL
STABILIZER PLATE, THICKNESS TO
BE DETERMINED BY JOIST
SUPPLIER
DECK BEARING EL
L4X3X1/4
STD SHEAR CONN
TYP
1/8
DECK BEARING EL
C
L
NOTE:
WHEN SUPPORT WIDTH IS LESS THAN 5 1/2", LAP JOISTS
SIDE BY SIDE AT SUPPORT FOR MIN BEARING
1/2" MIN
JOIST
BEAM
TYP
1/4 MIN
1/4 MIN
UNSLOTTED COLUMN
NOTE:
CLOSE COLUMN WITH 1/2" CAP PLATE, TYP
BEAM WEB, TYP FLANGE NOT
SHOWN
SINGLE PLATE CONNECTION (3/8"
MIN) SIZE TO SUIT SHEAR AND
MOMENT
NOTES:
1. WELDING WASHERS SHALL BE USED W/ DECK 26 GAGE AND THINNER.
2. USE SCREWS FOR ALL SIDELAPS IF FACTORY MUTUAL APPROVAL IS REQUIRED.
3. COORD REQUIREMENTS FOR SLOTS VENTS IN DECK W/ CONC INSULATING FILL.
3/4" DIA PUDDLE
WELDS OR WELDING
WASHERS @ 2'-0" AT
PERIMETER
COMPOSITE DECK
(4) 3/4" DIA PUDDLE WELDS OR (4)
WASHERS AT END AND
INTERMEDIATE SUPPORTS
#12 TEK SCREWS OR 1 1/2"
SEAM WELDS @ 2'-0"
CL OF END SUPPORT
CL OF INTERMEDIATE SUPPORT
WWF
BEAM
MIN
C L
R
SEE
ARCH
1/2" DIA DBA @ 12"
COMPOSITE DECK
CLOSURE STRIP
1/4" BENT PL CONT
" OUTRIGGER PL @ 24"
WHEN OVERHANG >8"
COMPOSITE DECK
#4x2'-0" @ 12"
WWF ABOVE ALL
OTHER REINF
CLOSURE STRIP BY DECK
SUPPLIER
GIRDER
L4x4x
CONT.
BEAM,
SEE PLAN
JOIST BRIDGING
PER JOIST MANUF.
JOIST
SEE PLAN
COMPOSITE DECK
BEAM,
SEE PLAN
L2 x2 x
AT EACH
JOIST
JOIST
SEE PLAN
COMPOSITE DECK
" BENT PL CONT.
EDGE OF DECK - PERPENDICULAR
3/4" = 1'-0"
EDGE OF DECK - PARALLEL
3/4" = 1'-0"
TYPICAL JOIST REINFORCEMENT
(CONCENTRATED LOAD)
3/4" = 1'-0"
TYPICAL JOIST TO END COLUMN CONNECTION
3/4" = 1'-0"
TYPICAL BEAM TO JOIST CONNECTION
3/4" = 1'-0"
TYPICAL JOIST TO BEAM INTERIOR CONNECTION
NOT TO SCALE
3/4" = 1'-0"
TYPICAL TUBE COLUMN CONNECTIONS
3/4" = 1'-0"
TYPICAL FLOOR DECK ATTACHMENT (3/4" PUDDLE WELDS)
3/4" = 1'-0"
TYPICAL COMPOSITE SLAB AT INTERIOR BEAM
3/4" = 1'-0"
TYPICAL COMPOSITE SLAB AT EXTERIOR
AND INTERIOR SLAB EDGES
3/4" = 1'-0"
TYPICAL COMPOSITE SLAB AT INTERIOR GIRDER
3/4" = 1'-0"
M A
T C
H
S
L A
B
D
E P
T H
SEE ARCH
CL
CL
TYP
AA
DETAIL AA
3/16
T/STL EL
W COL
L3 1/2X3 1/2 X5/16 DECK SUPPORT,
NS AND FS
?" BASE PL W/ (?) A325 BOLTS
STIFF PL EACH SIDE TO MATCH
FLANGE OF COL ABOVE, 3/8" MIN
L4X4X1/4
KICKER
TYPICAL POST UP COLUMN
3/4" = 1'-0"
SEE ARCH
TYPICAL EDGE OF DECK @ EXISTING BUILDING
3/4" = 1'-0"
(E) BUILDING
SEE 14 & 18/S-501
2" EXPANSION JOINT
BEAM, SEE PLAN
METAL DECK
WALL PANEL, SEE ARCH
SEE PLAN
JOIST, SEE PLAN
CL
TYP
T/STL EL
1/2" PL W/ (4) 1/2" DIA A325 BOLTS
3/8" PL (NS & FS)
NOTE: OMIT STIFF PL WHERE BM
FRAMES PERPENDICULAR ON COL CL
TYPICAL INTERIOR COLUMN CAP PLATE CONNECTION
3/4" = 1'-0"
STANDARD LINTEL SCHEDULE
3/4" = 1'-0"
STANDARD LINTEL SCHEDULE
OPENINGS UP TO 6'-0"
4" BRICK L5x3 1/2x3/8", LLH
OPENINGS 6'-0" TO 8'-0"
4" BRICK L5x5x3/8"
WALL SIZE LINTEL TYPE REMARKS
BEAM, SEE PLAN
METAL DECK
SEE PLAN
DECK BRNG EL
VARIES
L5x5x
L4x4x
@ 2'-8" O.C.
B/STEEL EL
SEE ARCH
" STIFFENER PL @
2'-8" O.C. N.S.&F.S.
M
BRICK LINTEL AT DOORWAY
3/4" = 1'-0"
VENEER, SEE
ARCH
PARAPET FRAMING AT BEAM CANTILEVER
3/4" = 1'-0"
ARCH VENEER
C6x13 CONT
C6x8.2 @ 4'-0" O.C. MAX
WALL, SEE ARCH
1 1/2" COMPENSATING STUD RUNNER
M
A X
T/PARAPET
SEE ARCH
3/16"
DECK BRG EL
" BENT PL @ CHANNEL
3/16"
3/16"
TYP
C6x13, TYP
BEAM, SEE PLAN
TYPICAL PARAPET FRAMING
3/4" = 1'-0"
COLUMN, SEE PLAN
" CAP PLATE
T/PARAPET
SEE ARCH
DECK BRG EL
(E) CMU WALL
L5x5x3/8
PORTION OF (E) WALL
TO BE REMOVED
T/OPENING
SEE ARCH
LINTEL AT DOOR OPENNING
3/4" = 1'-0"
(E) BRICK VENNER
3/8'' BENT PL6x5 (LLV)
1/4'' STEEL PLATE
HANDRAIL ATTACHMENT
3/4" = 1'-0"
METAL DECK
SEE PLAN
DECK BRNG EL
SEE PLAN
3/8" STIFFENER PL
3/8" STIFFENER PL
FOR HANDRAIL
ATTACHMENT
6"
MAX
BEAM
HANDRAIL
ATTACHMENT
BY OTHERS
TYP
HANDRAIL, SEE ARCH
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
Office of
Construction and Facilities
Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
JMW JBM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON ROAD, MURFREESBORO,
TN 37129
05/07/2019
FINAL CONSTRUCTION DOCUMENTS
626-308
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
STEEL FRAMING DETAILS
S-501
S-501
S-501
S-501
D
M
I
N
D
SEAL
WELD
CL COL
T/FDN
EL
BRACE
3/8" MIN GUSSET PL
3/16" COVER PL, NS AND FS
BASE PLATE, SEE ?/S??
WP
NOTE:
GUSSET PLATE AND WELDS TO
BE SIZED BY SUPPLIER
D
D
M
I
N
SEAL
WELD
NOTE:
GUSSET PL, SHEAR CONNECTION AND WELDS TO BE SIZED
BY SUPPLIER
C COL
L
C BEAM
L
T/STL EL
WP
3/16" COVER PL NS AND FS, TYP
3/8" MIN GUSSET PL
BRACE
D
D
M
I
N
SEAL
WELD
TYP
NOTE:
GUSSET PL AND WELDS TO BE SIZED BY
SUPPLIER
T/STL EL
3/16" COVER PL
NS AND FS, TYP
3/8" MIN GUSSET PL, TYP
BRACE, TYP
3/8" STIFF PL
(NS AND FS)
WP
TYPICAL VERTICAL BRACE AT END COLUMN AT ROOF
3/4" = 1'-0"
TYPICAL VERTICAL BRACE AT BEAM (DOUBLE)
3/4" = 1'-0"
TYPICAL VERTICAL BRACE AT FOUNDATION
3/4" = 1'-0"
TYP
TYP
LATERAL FRAME ELEVATION - ALONG G
3/8" = 1'-0"
LATERAL FRAME ELEVATION - ALONG 40
3/8" = 1'-0"
LATERAL FRAME ELEVATION - ALONG A
3/8" = 1'-0"
DECK BRG EL
T/STL EL
T/FTG EL
T/SLAB EL
DECK BRG EL
T/STL EL
T/FTG EL
T/SLAB EL
DECK BRG EL
T/STL EL
T/FTG EL
T/SLAB EL
34 37F D37 40
S-502
S-502
S-502
S-502
S-502
S-502
S-502
S-502
S-502
H
S
S x x
BEAM, SEE PLAN
BEAM, SEE PLAN
BEAM, SEE PLAN
BEAM, SEE PLAN
BEAM, SEE PLAN
BEAM, SEE PLAN
H
S
S x x
H
S
S x x
H
S
S x x
S x x
H
S
S x x
S x x
H
S
S x x
H
S
S x x
H
S
S x x
H
S
S x x
H
S
S x x
NOTES:
1. Va=x INDICATES MAXIMUM ALLOWABLE SHEAR IN KIPS.
MINIMUM ALLOWABLE SHEAR SHALL BE 10 KIPS.
2. Pa=x INDICATES MAXIUMUM ALLOWABLE AXIAL FORCE IN KIPS.
MINIMUM ALLOWABLE AXIAL FORCE SHALL BE 5 KIPS
C O
L U
M N
S
P
A
N
C O
L U
M N
S
A
N
C O
L U
M N
S
A
N
C O
L U
M N
S
A
N
C O
L U
M N
S
A
N
C O
L U
M N
S
A
N
NOTES:
1. Va=x INDICATES MAXIMUM ALLOWABLE SHEAR IN KIPS.
MINIMUM ALLOWABLE SHEAR SHALL BE 10 KIPS.
2. Pa=x INDICATES MAXIUMUM ALLOWABLE AXIAL FORCE IN KIPS.
MINIMUM ALLOWABLE AXIAL FORCE SHALL BE 5 KIPS
NOTES:
1. Va=x INDICATES MAXIMUM ALLOWABLE SHEAR IN KIPS.
MINIMUM ALLOWABLE SHEAR SHALL BE 10 KIPS.
2. Pa=x INDICATES MAXIUMUM ALLOWABLE AXIAL FORCE IN KIPS.
MINIMUM ALLOWABLE AXIAL FORCE SHALL BE 5 KIPS
a
K
K
K
K
K
K
K
K
K
K
K
K
SIM
Va = 11K
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
Office of
Construction and Facilities
Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
JMW JBM
USP 800 PHARMACY
COMPLIANCE FOR YORK
VAMC - TVHS
3400 LEBANON ROAD, MURFREESBORO,
TN 37129
05/07/2019
FINAL CONSTRUCTION DOCUMENTS
626-308
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S-502
S-502
S-502
S-502
LATERAL FRAMING DETAILS
S-502
S-502
S-502
| Murfreesboro Pharm |
| Sheets and Views |
| S-001 General Notes |
| S-301 Foundation Details |
| S-501 Steel Framing Details |
| S-502 Lateral Framing Details |
| S-Murfreesboro Pharmacy_v17 |
| Sheets |
| S-101 - GROUND FLOOR PLAN |
| S-102 - FIRST FLOOR - EQUIPMENT PLAN |
| S-103 - ROOF FRAMING PLAN |
| 2019-05-07T14:49:05-0700 | |
| Digitally verifiable PDF exported from www.docusign.com |
File details come from the government source that posted it.