36C24818R0737-026.pdf
PDF 28 MB Posted
- Attached to
- Project 546-16-104 Renovate Ambulatory Surgery
- Solicitation number
- 36C24818R0737
About this file
36C24818R0737 546-16-104 Final Submittal Drawings_Part3.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24818R0737-0003000.docx | DOCX document | |
| 36C24818R0737-0002000.docx | DOCX document | |
| 36C24818R0737-0002003.pdf | ||
| 36C24818R0737-0002001.pdf | ||
| 36C24818R0737-0002002.pdf | ||
| 36C24818R0737-0001001.pdf | ||
| 36C24818R0737-0001000.docx | DOCX document | |
| 36C24818R0737-024.pdf | ||
| 36C24818R0737-021.pdf | ||
| 36C24818R0737-029.pdf | ||
| 36C24818R0737-023.pdf | ||
| 36C24818R0737-019.docx | DOCX document | |
| 36C24818R0737-020.pdf | ||
| 36C24818R0737-022.pdf | ||
| 36C24818R0737-027.pdf | ||
| 36C24818R0737-025.pdf | ||
| 36C24818R0737-028.pdf | ||
| 36C24818R0737-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
79392 Ryan E. Morriss, PE
COA # 8304 Project # 2016627
550 North Reo Street Suite 203, Tampa, FL 33609 813.289.4700
A R C H I T E C T SJ O H N P O E
3131 NEWMARK DRIVE
SUITE 200
MIAMISBURG, OHIO 45342
937 461 3290 PHONE
jpa@johnpoe.com
GENERAL NOTES
A. ALL SERVICE INTERRUPTIONS TO THIS EXISTING
FACILITY MUST BE SCHEDULED AT LEAST 3
WEEKS IN ADVANCE AND BE KEPT TO A
MINIMUM. COORDINATE ALL DISRUPTIVE WORK
AND OUTAGE REQUIREMENTS WITH THE COR.
B. REFER TO SHEET G200 FOR PHASING PLAN.
C. THESE DRAWINGS ARE DIAGRAMMATIC IN
NATURE AND DO NOT NECESSARILY SHOW ALL
ELBOWS, OFFSETS, UNION, VALVES AND
FITTINGS REQUIRED TO COMPLETE THE
INSTALLATION OF THE WORK.
D. ISOMETRIC IS FOR DIAGRAMMATIC PURPOSES
ONLY AND SHOULD NOT BE SCALED. REFER TO
ARCHITECTURAL PLANS FOR SCALED
DRAWINGS.
E. ALL DOMESTIC WATER PIPING SHALL BE 1/2"
UNLESS NOTED OTHERWISE.
F. ALL WASTE PIPING SHALL BE 4" AND ALL VENT
PIPING SHALL BE 2" UNLESS NOTED OTHERWISE.
Scale:1 SEVENTH FLOOR SANITARY - PLUMBING ISOMETRIC N.T.S.
ISOMETRIC KEYNOTES--
1. EXISTING PIPING RISER CONTINUES TO 8TH
FLOOR AND ABOVE.
2. EXISTING PIPING RISER CONTINUES TO 6TH
FLOOR AND BELOW.
S-1
1.4 wsfu
S-2
1.4 wsfu
S-3
1.4 wsfu
ICE MAKER
SS-1
3.0 wsfu
LAV-1
2.0 wsfu
LAV-1
2.0 wsfu
LAV-1
2.0 wsfu
LAV-1
2.0 wsfu
LAV-22
2.0 wsfu
LAV-2
2.0 wsfu
LAV-2
2.0 wsfu
LAV-2
2.0 wsfu
LAV-2
2.0 wsfu
LAV-2
2.0 wsfu
LAV-2
2.0 wsfu
LAV-2
2.0 wsfu
WC-1
10.0 wsfu
WC-1
10.0 wsfu
WC-1
10.0 wsfu
WC-1
4 dfu
WC-1
4 dfu
WC-1
4 dfu
LAV-2
2 dfu
LAV-2
2 dfu
LAV-2
2 dfu
LAV-2
2 dfu
LAV-2
2 dfu
LAV-2
2 dfu
LAV-2
2 dfu
LAV-2
2 dfu
LAV-1
2 dfu
LAV-1
2 dfu
LAV-1
2 dfu
LAV-1
2 dfu
SS-1
2 dfu
S-3 2 dfu S-2
2 dfu
S-1 2 dfu
Scale:2 SEVENTH FLOOR DOMESTIC WATER - PLUMBING ISOMETRIC N.T.S.
FD-1
2 dfu
3/4" HW
1-1/4" CW
3/4" HW
1-1/4" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
3/4" HW
1-1/4" CW
IB-1
0.25 wsfu
WCO
FD-1
2 dfu
WCO
WCO
WCO
WCO
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
8TH FLOOR
7TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
7TH FLOOR
6TH FLOOR
11 11
FD-1
2 dfu
FD-1
2 dfu
FD-1
2 dfu
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1-1/4" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CWW1
1/2" HW
1/2" CW
3/4" HWW
1-1/4" CW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1-1/4" CW
1/2" HW
1/2" CW
1-1/4" CW
1" CW
1" CW
1" CW
2" SAN
2" SAN
4" SAN
2" SAN
4" SAN
2" SAN
4" SAN
2" SAN
2" SAN
2" SAN
2" VENT
2" VENT
2" VENT
2" VENT
2" VENT
2" VENT
2" VENT
4" SAN
4" VENT
4" SAN (E)
4" VENT (E)
4" SAN (E)
4" VENT (E)
4" SAN (E)
4" VENT (E)
4" SAN
4" VENT
4" SAN
4" VENT
4" SAN
4" VENT
2" VENT
4" SAN (E)
4" VENT (E)
4" SAN (E)
4" VENT (E)
4" SAN (E)
4" VENT (E)
4" SAN (E)
4" VENT (E)
4" SAN (E)
4" VENT (E)
2" SAN
2" SAN
4" SAN
2" SAN
3" SAN
4" SAN
4" SAN
2" SAN
4" SAN
4" SAN
4" SAN
4" SAN
2" SAN
4" SAN
2" SAN
2" SAN
2" SAN
4" SAN
4" VENTT
4" SAN
4" VENT
2" VENT
2" VENT
2" VENT
4" VENT
4" VENT
4" VENT
4" SAN
4" VENT
2" VENT
2" VENT
2" VENT
2" SAN
4" VENTT
2" VENT
2" VENT
2" VENTTT
2" VENT
2" VENT
4" VENT
FD-1
2 dfu
79392 Ryan E. Morriss, PE
COA # 8304 Project # 2016627
550 North Reo Street Suite 203, Tampa, FL 33609 813.289.4700
A R C H I T E C T SJ O H N P O E
3131 NEWMARK DRIVE
SUITE 200
MIAMISBURG, OHIO 45342
937 461 3290 PHONE
jpa@johnpoe.com
GENERAL NOTES
A. ALL SERVICE INTERRUPTIONS TO THIS EXISTING
FACILITY MUST BE SCHEDULED AT LEAST 3
WEEKS IN ADVANCE AND BE KEPT TO A
MINIMUM. COORDINATE ALL DISRUPTIVE WORK
AND OUTAGE REQUIREMENTS WITH THE COR.
B. REFER TO SHEET G200 FOR PHASING PLAN.
C. THESE DRAWINGS ARE DIAGRAMMATIC IN
NATURE AND DO NOT NECESSARILY SHOW ALL
ELBOWS, OFFSETS, UNION, VALVES AND
FITTINGS REQUIRED TO COMPLETE THE
INSTALLATION OF THE WORK.
D. ISOMETRIC IS FOR DIAGRAMMATIC PURPOSES
ONLY AND SHOULD NOT BE SCALED. REFER TO
ARCHITECTURAL PLANS FOR SCALED
DRAWINGS.
Scale:1 SEVENTH FLOOR ISOMETRIC - MEDICAL GAS N.T.S.
ISOMETRIC KEYNOTES--
1. EXISTING MEDGAS PIPING CONTINUES TO
OUTSIDE OF SCOPE.
3/4" MA
3/4" MO2
1" MV
3/4" MA
3/4" MO2
1" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
3/4" MA
3/4" MO2
3/4" MV
3/4" MA
3/4" MO2
1" MV
3/4" MA
3/4" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
ZVB
ZVB
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
MGO-1
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
1/2" MA
1/2" MO2
3/4" MV
A C
B
S S
S
AS-1
S
AS-1
S
S
NOTES:
1. BASIS OF DESIGN EQUIPMENT WITH REQUIRED PERFORMANCE CHARACTERISTICS IS SCHEDULED. OTHER MANUFACTURES ARE ACCEPTABLE; HOWEVER EQUIPMENT NOT MEETING EQUIVALENT PERFORMANCE
CRITERIA CANNOT BE CONSIDERED.
2. HOT WATER REHEAT COIL SHALL HAVE A MAXIMUM WATER PRESSURE DROP OF 3.0 FT. WG.
3. ALL AIR TERMINAL UNITS SHALL BE PRESSURE INDEPENDENT TYPE WITH VELOCITY RESET CONTROLLERS.
4. FURNISH AND INSTALL SPACE ENVIRONMENTAL CONTROLLER AND DISPLAY, PRESSURE DIFFERENTIAL SENSORS AND INTERLOCKS TO MAINTAIN REQUIRED SPACE PRESSURE DIFFERENTIAL.
5. PROVIDE FACTORY WIRED NON-FUSED DISCONNECT SWITCH ON TERMINAL UNIT.
1. IN GENERAL, PLANS DRAWINGS, PLANS AND DETAILS ARE DIAGRAMMATIC IN NATURE AND SHOULD NOT BE SCALED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY SPACE ALLOCATED PRIOR TO ORDERING EQUIPMENT.
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH SUBMITTED EQUIPMENT TO ENSURE ALL INLET/OUTLET CONNECTIONS COORDINATE WITH FIELD INSTALLED DUCTWORK AND MAKE ANY NECESSARY DUCT
MODIFICATIONS TO ENSURE PROPER OPERATION OF MECHANICAL EQUIPMENT.
3. SUBMITTALS SHALL MEET SCHEDULED DESIGN CHARACTERISTICS. THIS INCLUDES BUT NOT LIMITED TO CFMS, EAT(DB/WB), ESP, CAPACITIES, VOLTAGES/PHASES, MCA/MOCP, SONES, ETC.
4. ALL CONSTRUCTION WORK SHALL ALSO MEET THE FOLLOWING BUILDING CODE REQUIREMENTS:
* FLORIDA BUILDING CODE (FBC) 2014
* FBC ENERGY CONSERVATION 2014
* FBC MECHANICAL CODE 2014
* FBC PLUMBING CODE 2014
5. ALL WALL-MOUNTED THERMOSTATS AND/OR TEMPERATURE SENSORS SHALL BE INSTALLED AT AN ELEVATION OF 48" ABOVE FINISHED FLOOR TO THE TOP UNLESS OTHERWISE NOTED ON DRAWINGS. LOCATION OF WALL-MOUNTED THERMOSTATS SHALL BE COORDINATED WITH OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THERMOSTATS SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER OR REPRESENTATIVE IN THE FIELD.
6. ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PAINT INSIDE EACH RETURN GRILLE'S PLENUM AND DUCT CONNECTION FLAT BLACK TO CONCEAL CONNECTION. COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES AND FIRE SPRINKLER HEADS. PRIOR TO INSTALLATION, THE CONTRACTOR IS TO REFER TO AND COORDINATED WITH THE ARCHITECTURAL REFLECTED CEILING PLAN.
7. DIFFUSERS/GRILLES SHALL NEVER BE INSTALLED ON SURFACE OF ACOUSTICAL LAY-IN TILE. ALL DIFFUSERS/GRILLES IN LAY-IN CEILINGS SHALL BE LAY-IN PANEL MOUNT. REFER TO SCHEDULE. GYPSUM BOARD SURFACE MOUNT DIFFUSERS
SHALL NOT BE BEVEL MOUNT.
8. CONTRACTOR SHALL COORDINATE DIFFUSER/GRILLE LOCATIONS WITH STRUCTURE IN EXPOSED SITUATIONS IN ORDER TO ENSURE AIR IS NOT DIRECTLY SUPPLIED OR RETURNED OVER STRUCTURE OR OTHER TRADE COMPONENTS SUCH AS FIRE SPRINKLER PIPING, PLUMBING PIPING, ETC., CAUSING DUST ACCUMULATION. DUCTWORK ALONG WITH DIFFUSER/GRILLE LOCATIONS SHALL BE INSTALLED SYMMETRICALLY WITH ANY ADJACENT DUCTWORK/GRILLES.
CENTER DIFFUSERS/GRILLES BETWEEN STRUCTURAL MEMBERS WHERE DUCTWORK AND STRUCTURAL MEMBERS ARE EXPOSED. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL INSTALLATION APPEARANCE AND SHALL MAKE APPROPRIATE CHANGES WHERE DIRECTED BY ARCHITECT/ENGINEER AT THEIR OWN EXPENSE WHERE ITEMS ARE NOT
INSTALLED PER ABOVE STANDARDS.
9. CONTRACTOR SHALL PROVIDE A COPY OF THE TEST AND BALANCE REPORT BY AN AABC OR NEBB CERTIFIED AGENCY.
THIS REPORT MUST BE REVIEWED AND APPROVED BY THE ENGINEER PRIOR TO THE FINAL INSPECTION. THE CONTRACTOR MUST ALSO PROVIDE ALL REPORTS REQUIRED BY THE SPECIFICATION. OUTDOOR TEMPERATURE (DB);
OUTSIDE AIR (DB/WB & CFM); SUPPLY AIR AT UNIT DISCHARGE (DB/WB & CFM); RETURN AIR {MIXED} (DB/WB & CFM);
LEAVING COIL (DB/WB); DIFFUSER/GRILLE (DB/WB); EQUIPMENT (EWT/LWT); EQUIPMENT (EAT/LAT); EQUIPMENT (GPM);
EQUIPMENT (PRESSURES). OUTSIDE AIR CFM SHALL BE MEASURED DIRECTLY AND NOT CALCULATED FROM THE
DIFFERENCE BETWEEN SUPPLY AIR CFM AND RETURN AIR CFM.
10. ALL DUCTWORK MUST BE INSTALLED 6" AWAY FROM ANY FIRE RATED WALL TO FACILITATE INSPECTION.
11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND PLUMBING SHALL BE INSTALLED PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS ELECTRICAL CONDUITS, SMALL WATER LINES, ETC. IDEALLY DUCTWORK SHALL BE INSTALLED FIRST.
12. PROVIDE FIRE, SMOKE, AND FIRE/SMOKE DAMPERS WHERE REQUIRED BY SECTION 607.5 OF THE FBC - MECHANICAL, AND PROVIDE ACCESS AND IDENTIFICATION AS REQUIRED BY SECTION 607.4 OF THE FBC - MECHANICAL. MECHANICAL CONTRACTOR SHALL PROVIDE CEILING RADIATION DAMPERS WHERE REQUIRED BY SECTION 607.6.2 OF THE FBC - MECHANICAL. ALL FIRE DAMPERS SHALL BE DYNAMIC FIRE DAMPERS, UNLESS OTHERWISE NOTED.
13. WHERE SMOKE OR FIRE/SMOKE DAMPERS ARE REQUIRED, THE ELECTRICAL OR FIRE ALARM CONTRACTOR (MECHANICAL CONTRACTOR TO COORDINATE) SHALL PROVIDE 120V POWER AND ENSURE PROPER OPERATION UPON ACTIVATION. DAMPER ACTUATION SHALL BE BY ONE OF THE METHODS LISTED IN SECTION 607.3.3.2 OF THE FBC - MECHANICAL. WHEN SECTION 607.3.3.2 REQUIRES A DUCT SMOKE DETECTOR AT THE DAMPER, THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL THE DETECTOR WITHIN THE DUCTWORK. THE ELECTRICAL OR FIRE ALARM CONTRACTOR (MECHANICAL CONTRACTOR TO COORDINATE) SHALL PROVIDE 120V POWER AND ENSURE PROPER DETECTOR OPERATION. OTHER THAN IN MECHANICAL SMOKE CONTROL SYSTEMS, UPON ACTIVATION, THE DAMPER SHALL CLOSE, THE ASSOCIATED AIR DISTRIBUTION SYSTEM SHALL SHUT DOWN, AND A SUPERVISORY SIGNAL SHALL BE
GENERATED PER SECTION 606.4 OF THE FBC - MECHANICAL.
14. OTHER THAN IN MECHANICAL SMOKE CONTROL SYSTEMS, DURING AN AUTOMATIC FIRE ALARM ACTIVATION, FANS OPERATING IN THE ZONE IN ALARM SHALL SHUT DOWN AND SMOKE AND FIRE/SMOKE DAMPERS SHALL CLOSE.
15. PENETRATIONS THROUGH SMOKE OR FIRE-RATED ASSEMBLIES: PENETRATIONS FOR PIPES, CONDUITS OR OTHER PURPOSES THROUGH ASSEMBLIES (FLOORS, ROOF, WALLS, PARTITIONS, ETC.) WITH A REQUIRED FIRE RESISTANCE RATING SHALL BE SEALED TO THE PENETRATING MEMBER IN AN APPROVED MANNER WHICH MAINTAINS THE REQUIRED
FIRE RESISTANCE RATING OF THE ASSEMBLY AS FOLLOWS:
16. WHERE HOLES FOR PENETRATIONS ARE FORMED CIRCULAR OR CORE-BORED, THE PENETRATION SHALL BE PROTECTED WITH FIRE-SEAL BRAND SMOKE AND FIRE STOP FITTINGS MFG. BY O-Z GEDLEY, LINK SEAL BRAND BY
THUNDER LINE OR AN EQUAL APPROVED BY ENGINEER.
17. WHERE HOLES FOR PENETRATIONS ARE IRREGULAR (NON-CIRCULAR) IN SHAPE, THE PENETRATION SHALL BE PROTECTED WITH DOW CORNING 3-6548, SILICONE RTV FOAM, 3M FIRE BARRIER PENETRATION SEAL SYSTEM OR AN
EQUAL APPROVED BY THE ENGINEER.
18. INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. THE CONTRACTOR IS TO VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION SUBCONTRACTORS BEFORE ANY
CONSTRUCTION WORK.
19. FLEXIBLE AND RIGID ROUND DUCT TAKE-OFFS FOR DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER NECK. MAXIMUM
FLEXIBLE DUCT LENGTH SHALL BE 5'-0".
20. COORDINATE DUCT ELEVATION WITH RAIN LEADERS, WATER PIPING, SANITARY DRAINS AND MAJOR ELECTRICAL
CONDUITS.
21. CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND/SUPPORT MECHANICAL
EQUIPMENT AND MATERIALS.
22. IT IS THE RESPONSIBILITY OF THE MECHANICAL INSTALLER TO PATCH AND REPAIR ANY DUCT OPENINGS WHICH RESULT FROM THE RELOCATION OR ELIMINATION OF ANY EXISTING AIR DEVICES. THE PATCH IS TO BE OF A SIMILAR MATERIAL
TO THE REPAIRED DUCT AND TO BE SEALED IN ACCORDANCE WITH SMACNA STANDARDS.
23. PROVIDE ADDITIONAL DUCTWORK AND PIPING SUPPORTS ON BOTH SIDES AND WITHIN 18" OF FIRE RATED WALL.
DUCTWORK OR PIPING SHALL NOT BE SUPPORTED FROM ANY FIRE RATED WALL.
24. FOR DUCTWORK PENETRATING ONE HOUR FIRE RATED WALL, THE ENTIRE DUCT SYSTEM, TO BE CONSTRUCTED PER SMACNA STANDARDS WITH A MINIMUM OF 26 GA. STEEL DUCT AND SHALL CONTINUE IN THE HORIZONTAL DIRECTION WITHOUT ANY GRILLE OR OPENING FOR NOT LESS THAN 5'-0" FROM THE WALL AND DUCT SHALL NOT EXCEED SQUARE
INCH REQUIREMENTS OF LOCAL CODE, OTHERWISE A FIRE DAMPER SHALL BE PROVIDED.
25. PROVIDE TURNING VANES IN ALL RECTANGULAR SUPPLY DUCT ELBOWS WITH ANGLES FROM 45 DEGREES TO 90 DEGREES, PER FIGURES 4-3 AND 4-4 OF THE SMACNA MANUAL. PROVIDE SINGLE WALL VANE CONSTRUCTION FOR
DUCTS UP TO 48" WIDE, AND DOUBLE WALL VANE CONSTRUCTION FOR LARGER DIMENSIONS.
26. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS (FREE AREA).
27. CONTRACTOR SHALL COORDINATE ALL INTAKE/EXHAUST LOCATIONS TO ENSURE MINIMUM 10'-0" DISTANCE BETWEEN
ANY INTAKES AND VENTILATION EXHAUSTS, PLUMBING VENTS, RELIEF, ETC.
28. ALL HVAC EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS UNLESS INDICATED
OTHERWISE.
29. CONTRACTOR SHALL THOROUGHLY CLEAN AND ENSURE PROPER OPERATION OF ANY EXISTING HVAC EQUIPMENT. ANY CHANGE TO THE SYSTEM SHALL RESULT IN EQUIPMENT MODIFICATIONS (AS REQUIRED) INCLUDING BUT NOT LIMITED
TO REPLACING MOTORS, VFDS, PULLEYS, SHEAVES, BELTS, ETC.
30. CONTRACTOR SHALL PROVIDE A PERMANENT/PROFESSIONAL LABEL FOR EACH PIECE OF EQUIPMENT AND ASSOCIATED
THERMOSTAT(S) AND/OR SENSOR(S).
31. DUCTWORK, DIFFUSERS, REGISTERS, GRILLES, AND OTHER ITEMS OF THE AIR HANDLING SYSTEM SHALL NOT BE
SUPPORTED BY THE CEILING OR CEILING SUSPENSION SYSTEM.
32. ALL SUPPLY AND RETURN DUCTWORK SHALL BE EXTERNALLY INSULATED SHEET METAL CONSTRUCTION IN ACCORDANCE WITH LATEST SMACNA STANDARDS. DUCT INSULATION TO BE 2.0" THICK FOIL BACK WRAP, K=0.25 BTUH-IN./SF. HR° 1.50#/CF AS MANUFACTURED BY JOHNS MANVILLE. JOINTS TO BE STAPLED AND TAPED WITH PRESSURE SENSITIVE TAPE AS MANUFACTURED BY COMPAC INDUSTRIES MODEL #120 (FLAME SPREAD = 5, SMOKE
DEVELOPED = 10) OTHER ACCEPTABLE MANUFACTURERS ARE OWENS CORNING AND KNAUF.
33. EXPOSED DUCTWORK SHALL BE DOUBLE WALL INSULATED DUCT EQUAL TO LINDAB "SPIROSAFE OR SPIROOVAL DOUBLE WALL SELF SEALING DUCT" W/2" R=8 INSULATION. DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH LATEST SMACNA STANDARDS UNLESS OTHERWISE NOTED. ALL EXPOSED DUCT SHALL CONTAIN FACTORY ADDED DIFFUSERS/GRILLES. EQUAL TO SCHEDULED MAKE AND MODEL. PAINT GRIP AND PAINT PER ARCHITECT. UNLESS
OTHERWISE NOTED.
34. ALL EXHAUST DUCT WORK SHALL BE NON-INSULATED SHEET METAL UNLESS OTHER WISE NOTED.
35. FLEXIBLE DUCT SHALL HAVE CONTINUOUS TEAR RESISTANT LINER ENCASED BY INSULATING MATERIAL WITH AN OUTER VAPOR JACKET CONFORMING TO UL181 UNLESS THE FLEX DUCT MEETS THE CRITERIA STATED IN 2014 FLORIDA
BUILDING CODE-BUILDING SECTION 419.3.6.4.
36. COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES, FIRE SPRINKLER HEADS, AND OTHER DEVICES.
37. CONTRACTOR SHALL REFER TO ALL DETAILS FOR PROPER GUIDANCE.
38. CLOSE OUT DOCUMENTS: CONTRACTOR SHALL MAINTAIN A SET OF AS-BUILT DRAWINGS AND KEEP CURRENT DURING CONSTRUCTION OF THE PROJECT. IT IS TO INCLUDE ALL CONTRACT CHANGES, MODIFICATIONS AND CLARIFICATIONS.
THIS SET TOGETHER WITH ALL SHOP DRAWINGS SHALL BE TURNED OVER TO THE ARCHITECT/ENGINEER AFTER
CONSTRUCTION COMPLETION.
MECHANICAL NOTES MECHANICAL LEGEND
DUCTWORK SYMBOLS
LIMIT OF DEMOLITION
(WALL TYPE)
(WALL TYPE)
DN
DN
UP
UP
SUPPLY DUCT (UP & DOWN)
EXHAUST DUCT (UP & DOWN)
SQUARE 4-WAY CEILING DIFFUSERS
SUPPLY TOP REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN CEILING REGISTER OR GRILLE
EXHAUST OR RETURN BOTTOM REGISTER OR GRILLE
EXHAUST OR RETURN REGISTER OR TOP GRILLE
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
CONNECT NEW DUCT TO EXISTING DUCT
D
INCLINED RISE, IN DIRECTION OF AIR FLOW
INCLINED DROP, IN DIRECTION OF AIR FLOW
R
DNUP RETURN DUCT (UP & DOWN)
SQUARE 3-WAY CEILING DIFFUSERS
SQUARE 2-WAY CEILING DIFFUSERS
FC
10ø
FLEXIBLE CONNECTION, EQUIPMENT,
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
VANED ELBOW (SHORT RADIUS)
STANDARD RADIUS ELBOW (LONG RADIUS)
NEW ROUND DUCT (INSIDE DIMENSIONS: DIAMETER)
EXISTING DUCT TO REMAIN
SMOKE DAMPER
MANUAL VOLUME DAMPER
FLEXIBLE DUCTWORK (INSULATED)
FIRE DAMPER
VIBRATION, OR SEISMIC
SUPPLY
RETURN45°
RETURN, NO SPLITTER (45° TAP)
STANDARD BRANCH SUPPLY OR
45°
COMBINATION FIRE/SMOKE DAMPER
AUTOMATIC CONTROL DAMPER MODULATING
AUTOMATIC CONTROL DAMPER TWO POSITION
AIR TERMINAL SYMBOLS
TERMINAL UNIT WITH ELECTRIC HEAT
PIPING SYMBOLS
HOT WATER HEATING SUPPLY
DRAIN LINE
HOT WATER HEATING RETURN
HWSH S
HWRH R
D
XXX EXISTING PIPE TO BE REMOVED
GENERAL PIPING SYMBOLS
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
PRESSURE GAGE
THERMOMETER
PIPE UP
PIPE DOWN
VALVE SYMBOLS
BALL VALVE
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
THREE-WAY TWO POSITION CONTROL VALVE
FLEXIBLE CONNECTION
DUCTWORK SYMBOLS
DD FS
D
CONTROLS SYMBOLS
T ROOM THERMOSTAT - WALL MOUNTED
H ROOM HUMIDITY SENSOR - WALL MOUNTED
10x8 NEW RECTANGULAR DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
10x8ø NEW OVAL DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
DRAWING SYMBOLS
1-ATU28-10
SYSTEM NUMBER
BUILDING NUMBER
TERMINAL UNIT NUMBER TYPICAL TERMINAL UNIT DESIGNATION
FD
SD
79392 Ryan E. Morriss, PE
COA # 8304 Project # 2016627
550 North Reo Street Suite 203, Tampa, FL 33609 813.289.4700
A R C H I T E C T SJ O H N P O E
3131 NEWMARK DRIVE
SUITE 200
MIAMISBURG, OHIO 45342
937 461 3290 PHONE
jpa@johnpoe.com
AIR DEVICE SCHEDULE (SUPPLY)
MARK
BASIS OF DESIGN
TYPE
AIRFLOW PANEL
SIZE(IN.)
NECK
SIZE(IN.) REMARKS
MANUFACTURER MODEL MIN. MAX.
CD-1 PRICE ASPD PLAQUE FACE 30 CFM 80 CFM 24x24 6ø 1,2,3 CD-2 PRICE ASPD 85 CFM 180 CFM 24x24 8ø
AIR TERMINAL UNIT SCHEDULE
MARK LOCATION SYSTEM NOMINAL
SIZE
AIRFLOW MAX. TOTAL
UNIT
PRESSURE
DROP
HOT WATER HEATING COIL
CONTROL
TYPE
BASIS OF DESIGN
REMARKS
MAX CFM MIN CFM
HEATING
AIRFLOW
CFM
ENTERING
AIR TEMP.
F
ENTERING
WATER
TEMP.
LEAVING
WATER
TEMP.
HEATING
WA.FLOW
GPM
COIL
CAPACITY
BTU/H
HOT WATER
PIPING
RUNOUT SIZE
MANUFACTURER MODEL
NUMBER
1-ATU66-01 C702 (E)1-AH66 5 310 310 0.25 54.8 180 160 1.5 11,800 3/4" VAV CARRIER 35E-05 1,2,3,5
AIR DEVICE SCHEDULE (RETURN & EXHAUST)
MARK
BASIS OF DESIGN
TYPE
AIRFLOW PANEL
SIZE(IN.)
NECK
SIZE(IN.) REMARKS
MANUFACTURER MODEL MIN. MAX.
RG-1 PRICE 630D LOUVERED 40 CFM 100 CFM 24x24 - RG-2 PRICE 630D 300 CFM 595 CFM 24x24 - 1
NOTES:
1. FURNISH AND INSTALL WITH WHITE ALUMINUM GRILLE AND FACTORY PROVIDED SPEED CONTROLLER.
2. FURNISH AND INSTALL HANGING VIBRATION ISOLATOR AND NEOPRENE MOUNT HANGERS.
3. BASIS OF DESIGN EQUIPMENT WITH REQUIRED PERFORMANCE CHARACTERISTICS IS SCHEDULED. OTHER MANUFACTURERS ARE ACCEPTABLE, HOWEVER
EQUIPMENT NOT MEETING EQUIVALENT CRITERIA CANNOT BE CONSIDERED.
4. EQUIPMENT TO BE CONTROLLED BY ENVIRONMENTAL CONTROL PANEL, IN ORDER TO MAINTAIN SPACE PRESSURIZATION.
5. FURNISH AND INSTALL VFD TO MODULATE FAN OUTPUT FOR MAINTAINING ROOM PRESSURE SET POINT.
EXHAUST FAN SCHEDULE
MARK
BASIS OF DESIGN
TYPE SERVICE AIR FLOW
EXTERNAL
STATIC
PRESSURE
FAN
RPM
FAN
MOTOR
POWER
MOTOR
RPM
FAN
DRIVE
SOUND
LEVEL
(SONES)
ELECTRICAL
REMARKS
MANUFACTURER MODEL
NUMBER VOLTAGE PHASE
1-EFC703 GREENHECK SP-110-VG CEILING C703 100 CFM 0.30 in-wg 940 8 W 940 ECM 1.5 115 V 1 1,2,3
ABBREVIATIONS
(E) EXISTING
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ATU AIR TERMINAL UNIT
CAV CONSTANT AIR VOLUME
CD CEILING SUPPLY AIR DIFFUSER
CFM CUBIC FEET PER MINUTE
COR CONTRACTING OFFICER'S REPRESENTATIVE
CTE CONNECT TO EXISTING
EA EXHAUST AIR
EF EXHAUST FAN
FBC FLORIDA BUILDING CODE
FD FIRE DAMPER
FO FLAT OVAL
FPM FEET PER MINUTE
FSD COMBINATION FIRE SMOKE DAMPER
FT FOOT
GPM GALLONS PER MINUTE
HHWR HEATING HOT WATER RETURN
HHWS HEATING HOT WATER SUPPLY
IBC INTERNATIONAL BUILDING CODE
IN INCH
NC NOISE CRITERIA
OA OUTSIDE AIR
OAL OUTSIDE AIR LOUVER
OBD OPPOSED BLADE DAMPER
RA RETURN AIR
RG RETURN AIR GRILLE
SA SUPPLY AIR
SD SMOKE DAMPER
TAB TEST AND BALANCE
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
WG WATER GAGE
1-ATU66-02 (E)1-AH66 4 140 VAV
1-ATU66-03 (E)1-AH66 8 740 VAV
1-ATU66-04 (E)1-AH66 4 40 VAV
1-ATU66-05 (E)1-AH66 5 275 VAV
1-ATU66-06 (E)1-AH66 180 VAV
1-ATU66-07 (E)1-AH66 170 VAV 1,2,3,4,5
1-ATU66-08 (E)1-AH66 VAV
1-ATU66-09 (E)1-AH66 VAV
1-ATU66-10 (E)1-AH66 VAV
1-ATU66-11 (E)1-AH66 VAV
1-ATU66-12 (E)1-AH66 VAV
1-ATU66-13 (E)1-AH66 VAV
1-ATU66-14 (E)1-AH66 VAV
1-ATU66-15 (E)1-AH66 VAV
1-ATU66-16 (E)1-AH66 310 VAV
1-ATU66-17 (E)1-AH66 435 VAV
1-ATU66-18 (E)1-AH66 435 VAV
1-ATU66-19 (E)1-AH66 435 VAV
1-ATU66-20 (E)1-AH66 435 VAV
C708 C702 C707 B732
C710,C711,C712 C702A
1-EFC704 GREENHECK SP-110-VG CEILING C704 100 CFM 0.30 in-wg 940 8 W 940 ECM 1.5 115 V 1 1,2,3 1-EFC705 GREENHECK SP-110-VG CEILING C705 100 CFM 0.30 in-wg 940 8 W 940 ECM 1.5 115 V 1 1,2,3 1-EFC706 GREENHECK SP-110-VG CEILING C706 100 CFM 0.30 in-wg 940 8 W 940 ECM 1.5 115 V 1 1,2,3
C702B C702C C702D C702E C702F C702G C702H C702I C702N C702M C702L C702K C702J
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
CARRIER
35E-04 35E-08 35E-04 35E-05 35E-04 35E-04 35E-04 35E-04 35E-04 35E-04 35E-04 35E-04 35E-04 35E-04 35E-05 35E-06 35E-06 35E-06 35E-06
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
5,300 28,300 1,100 5,300 3,400 4,800 4,800 4,800 4,800 4,800 4,800 4,800 4,800 4,800 8,600
12,200
11,600
12,200 12,200
180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160 180 160
1.0 3.0 0.5 1.0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.5 1.5 1.5 1.5
54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8 54.8
1-EFC702A GREENHECK SQ-80-VG IN-LINE C702A 260 CFM 0.30 in-wg 1408 0.04 HP 1408 ECM 6.2 115 V 1 2,3,4,5
CD-3 PRICE ASPD 185 CFM 340 CFM 24x24 10ø CD-4 PRICE ASPD 345 CFM 500 CFM 24x24 12ø
NOTES:
1. BASIS OF DESIGN EQUIPMENT WITH REQUIRED PERFORMANCE CHARACTERISTICS IS SCHEDULED. OTHER MANUFACTURES ARE ACCEPTABLE, HOWEVER
EQUIPMENT NOT MEETING EQUIVALENT CRITERIA CANNOT BE CONSIDERED.
2. EQUIPMENT TO BE CONTROLLED VIA A HIGH HUMIDITY SIGNAL FROM THE ISOLATION ROOM ENVIRONMENTAL CONTROL PANEL. FURNISH AND INSTALL ALL
REQUIRED ACCESSORIES FOR A COMPLETE AND FUNCTIONING INSTALLATION.
DEHUMIDIFIER SCHEDULE
MARK
BASIS OF DESIGN
TYPE SERVICE CAPACITY
EXTERNAL
STATIC
PRESSURE
CURRENT
DRAW
DRAIN
CONNECTION
SOUND
LEVEL
dBA
ELECTRICAL
REMARKS
MANUFACTURER MODEL
NUMBER VOLTAGE PHASE
1-DHC702A APRILAIRE 1830 DUCTED C702A 3/4" 47 120 V 1 1,2
1-ATU66-21 C702 (E)1-AH66 5 300 300 54.8 180 160 1.5 11,800 3/4" VAV CARRIER 35E-05300
RG-3 PRICE 630 40 CFM 100 CFM 24x24 8x8 1,2
PC ROOM PRESSURE CONTROLLER & DISPLAY - WALL MOUNTED
PS ROOM PRESSURE SENSOR - WALL MOUNTED
NOTES:
1. RUNOUT BRANCH DUCT SHALL BE SAME SIZE AS INDICATED NECK SIZE.
2. FURNISH AND INSTALL VOLUME DAMPER IN BRANCH DUCT SERVING EACH DIFFUSER.
3. FURNISH AND INSTALL ALL REQUIRED ACCESSORIES FOR A COMPLETE INSTALLATION.
4. FURNISH AND INSTALL FIELD FABRICATED PLENUM.
NOTES:
1. FURNISH AND INSTALL ALL REQUIRED ACCESSORIES FOR A COMPLETE INSTALLATION.
2. FURNISH AND INSTALL WITH RETURN AIR SILENCER.
PLAQUE FACE
PLAQUE FACE
PLAQUE FACE
1,2,3 1,2,3 1,2,3
LOUVERED
LOUVERED
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
CD-5 PRICE AS - - 48x3 6øONE SLOT LINEAR 1,2,3,4
70 PPD 0.0-0.4 W.C. 160-70 6.3 A
AIR
FLOW
CFM
1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5
1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5 1,2,3,5
1-EFC709 GREENHECK SP-110-VG CEILING C709 100 CFM 0.30 in-wg 940 8 W 940 ECM 1.5 115 V 1 1,2,3
J K P Q R R.4M.3K.8
10.8
J.9
10.5
9.5
8.8
9.8
Stair S7-6
Prep/Recovery
C702CC
Prep/Recovery C702I
Prep/Recovery
C702HH
Prep/Recovery
C702GC702G
Prep/Recovery C702F
Prep/Recovery C702E
Prep/Recovery
C702DD
Prep/Recovery C702B
Sterile Supply C711
Clean Linen C710
Elec E72
Comm T72
Elec C713
Toilet C705
Prep/Recovery
C702NN
Prep/Recovery
C702MC702M
Prep/Recovery C702L
Prep/Recovery
C702KK
Prep/Recovery C702J
Nurse Manager
C707
Storage C712
Soiled Utility C706
Staff Lounge/ Lockers
B732
Elece
B732AB732
Toilet C703C703
Isolation
C702AA
Nurse Station C708
Toilet C704
HAC
C709
Prep Recovery
Area C702
Corridor C7-3-1
Corridor C7-8-1 g
7 n eri ly ile p e
8088C7088 M
00600
20X14
U
-0
1-
A
TUU
1 1- A
TU
-0
1- A
TU
-0
U
1-ATU66-04
1- A
TU
-0
1-
A T
1- A
T g1- A
TU
-0
T 6-toratora
1- A
TU
-0
1- A
TU
-0
1- A
TU
-0
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-1
1- A
TU
-2
Corridor
UUU
TT
UUU
AAA
5" Ø
4"Ø
4" Ø
4" Ø
4" Ø
4" Ø
4" Ø
4" Ø
4" Ø
4" Ø
4" Ø
5" Ø
6" Ø
6" Ø
6" Ø
6" Ø
4" Ø
18X12
X
Re
/R C7 oilet 703703 e
Ut it
6"Ø
6"Ø
6"Ø" 6" Ø
6" Ø
6" Ø
16X12
UU
4" Ø
TT
8" Ø
C
Nurs a
Nu
14X101
12X8 10X610X6
6X
6X
6X
X
8X
8X
8X
8X
88X
8X
8X
6X
6X 10 6X
202AA02A2A2A2A7700000007C7777C77777777C7C7CC7CC7CCCCCCCCCCCCCCCCCCCCCCCCCCC
yy
CC7C7711777777C7CC7C7C77C77711717111771771711777110111111111
Lii 00000 inniiiiinnennennnnnneeeneeeneeeennnnnnnnnnn
MMMaManMMMM N
CD-2
8"ø
170 CFM
CD-2
8"ø
170 CFM
CD-2
8"ø
170 CFM
CD-2
8"ø
170 CFM
CD-2
8"ø
170 CFM
CD-2
8"ø
170 CFM
CD-2
8"ø
170 CFM
CD-2
8"ø
175 CFM
CD-3
10"ø
200 CFM
CD-2
8"ø
100 CFM
CD-2
8"ø
175 CFM
CD-3
10"ø
310 CFM
CD-444
12"ø
435 CFM
CD-4
12"ø
435 CFM
CD-4
12"ø
435 CFM
CD-4
12"ø
415 CFM
P e Pre P e P e P p/ C verye
UUUU
10X8
CD-5
6"ø
80 CFM
CD-2D 2DD 2-2DDDDD 2DD 222DDD 222222DDD 22-DDDD 2222
8"øøøøøøøøøøøøøøøø" 150 CFMFCC00 MMFMC M0 CC00 MFMCF0 CCFMMMM00 CCCCFMM0 CCFFFMMMMMMMCC MMFFCCCCCC00 MMFFFFCCC555
CD-2
8"ø
150 CFM
CD-3
10"ø10"
200 CFM (2)
CD-2
8"ø
170 CFM70 CF
CD-2
8"ø
170 CFM
CD-2
8"ø
140 CFM CD-1
6"ø
40 CFM
CD-1
6"ø6"ø
40 CFM
CD-11
6"ø6 ø
40 CFM
CD-1CD
6"ø6"ø
40 CFM
5"Ø ery
1-EFC7037 3037077
1-EFC706C
1-EFC705705505
1-EFC70404
1-DHC702AACHHCCHHHHHCC AAA2AA02077C
FS
D
FS
D
FS
D
FS
D
FS
D
1- E
FC
2A2
10"Ø10 ØØ
10"Ø
10X80 8
5" Ø
5" Ø
10X810 810X81
1-ATU66-21UUU111
RG-2
12x12
RG-1
8x8
RG-1
8x8
RG-1
8x8
RG-1
8x8
RG-1
8x8
RG-1
8x8
RG-1
8x8
RG-1
8x8
RG-3
8x8
RG-1
8x8
RG-2
12x12
RG-2
12x12
RG-2
12x12
RG-2
12x12
RG-2
12x12
RG-2
12x12
RG-2
12x12
RG-22
12x122x1 ep ery
CD-2
8"ø 150 CFMCFC0055 M1 FMCF0 C00551 MMFM1 000 CFFMM550 CCFFM15000 CCFMMMMFMFFCCC001 MMMFFFC555511 MMFCC00555150 CFMCF5 M005 FM1150 C50005 CFMCFMFFCC
FS
D
FFFFFFFFS
D
FFS
D
FFFS
D
FFS
D
FFFFS
D
FFFFFS
D
FFSFFFFFS
D
FFFFF
CD-5
6"ø
80 CFM
C
707709
ACHA
AAACCC
1-EFC709
6X
6X
6X
6X
6X
6X
RECOVERY
C709
RECOVERY
C710
PATIENT ROOM
C711
C711A C710A C709A
OUTPATIENT RECOVERY
C707
C707A
Comm T72
Elec E72
Elec C713
LOUNGE
C706
LINEN
C705
PROGRAM MANAGER
C705B
NURSE MANAGER
C704B
ENGINEERING STORAGE
B732
SOILED UTILITY
C702
OFFICE
C703
FOYER
C704
C706AC705A
SUPPLY
C712
Toilet B701
OO
O
NNAAMM
CC7
MANMMAM
MA
UU
OOOO EDLE
C
E
CC
EE
5B5
MAAMMAM
OIOSOO EDEDELEEE UU
CCCC 202
OSOOSO
C7C7C
ELLEEE
C 22
UUDD UU
T
SS
S
A MMM MM
CC
NANA
55B05
A NN
OOO
CCC 505
AMM
MMMMAMM NAANNN N
O
A C
AA
C
A C
A C
A
OV
OV
OVO
C O
N N
NN
79392 Ryan E. Morriss, PE
KEY PLAN
COA # 8304 Project # 2016627
550 North Reo Street Suite 203, Tampa, FL 33609 813.289.4700
A R C H I T E C T SJ O H N P O E
3131 NEWMARK DRIVE
SUITE 200
MIAMISBURG, OHIO 45342
937 461 3290 PHONE
jpa@johnpoe.com
1. ALL EQUIPMENT WITHIN HATCHED AREA AND ALL PREVIOUSLY
ABONDONED EQUIPMENT SHALL BE REMOVED AND DISCARDED.
2. ALL EXISTING HYDRONIC PIPING IS TO BE REMOVED AND DISCARDED.
CAP HYDRONIC PIPING AT EXISTING FIRE RATED BARRIER WITHIN
SCOPE AREA.
3. REMOVE AND DISCARD ALL CONDENSATE BRANCH PIPING. ALL
CONDENSATE RISERS SERVING THE FLOORS ABOVE SHALL REMAIN.
4. ALL EXISTING PNEUMATIC CONTROL BRANCH PIPING SHALL BE
REMOVED AND DISCARDED. EXISTING PNEUMATIC MAIN RISERS
SHALL REMAIN AND BE CAPPED AT CONNECTION POINT.
A. ALL SERVICE INTERRUPTIONS TO THIS EXISTING FACILITY MUST BE SCHEDULED AT
LEAST 3 WEEKS IN ADVANCE AND BE KEPT TO A MINIMUM. COORDINATE ALL
DISRUPTIVE WORK AND OUTAGE REQUIREMENTS WITH THE COR.
B. EXISTING EQUIPMENT, PIPING, DUCTWORK, DIFFUSERS, GRILLES, AND ASSOCIATED
COMPONENTS SHOWN ON DRAWINGS ARE APPROXIMATE LOCATIONS AND IS
PROVIDED FOR REFERENCE USE ONLY. FIELD VERIFY AND COORDINATE WITH EXACT
LOCATIONS, ELEVATIONS, SIZES, AND CONDITIONS OF EXISTING COMPONENTS.
C. ALL EXISTING DUCTWORK TO BE REUSED SHALL BE PRESSURE TESTED,
THOROUGHLY CLEANED, AND SANITIZED TO AVOID POSSIBLE CONTAMINATION.
D. CONTRACTOR SHALL PAINT INTERIOR OF ALL GRILLES/DIFFUSERS VISIBLE FROM
SPACE FLAT BLACK. TYPICAL OF ALL.
E. PROVIDE THERMOSTAT AT 48" AFF WITH VENTILATED COVER AS DIRECTED.
F. ALL DUCTWORK/PIPING SHALL BE PROPERLY INSULATED AND ROUTED ABOVE
CEILING THROUGH FREE AREA OF STRUCTURAL MEMBERS. CONTRACTOR SHALL
COORDINATE AN FIELD VERIFY ALL ROUTING WITH OTHER TRADES PRIOR TO WORK.
G. CONTRACTOR SHALL PROVIDE A PERMANENT/PROFESSIONAL LABEL FOR EACH (AHU,
ATU) AND ASSOCIATED THERMOSTAT(S) AND TEMPERATURE SENSOR(S).
H. CONTRACTOR SHALL REFER TO ALL DETAILS FOR PROPER GUIDANCE.
I. CONTRACTOR SHALL PROPERLY SEAL CAULK ALL PENETRATION THRU FIRE
RATED/SMOKE RATED/FIRE SMOKE RATED WALLS. (PER CODE)
J. ALL DUCTWORK/DIFFUSERS/GRILLES PENETRATING FIRE RATED CEILING/WALLS
SHALL CONTAIN FIRE DAMPERS, PER DETAILS.
K. CONTRACTOR SHALL VERIFY WALL/FLOOR TYPES PRIOR TO WORK INSTALLING FIRE
AND/OR SMOKE DAMPERS IN DUCT WORK AT ALL FIRE/SMOKE RATED WALL/FLOOR
PENETRATIONS. PER SPEC.
L. DUCTWORK UP STREAM OF ATU BOX SHALL EQUAL ATU BOX OPENING. ALL
DUCTWORK DOWN STREAM OF ATU BOX SHALL ADAPT TO ATU OPENING VIA
FLEXIBLE CONNECTIONS.
XX
GENERAL NOTES
DEMOLITION KEYNOTES
Scale: 1/8" = 1'-0"2 SEVENTH FLOOR RENOVATION PLAN - MECHANICAL HVAC
Scale: 1/8" = 1'-0"1 SEVENTH FLOOR DEMOLITION PLAN - MECHANICAL HVAC
11 TYP.T
22 TYP.T
33 TYP.YPPT
44TYP.
1. PROVIDE SPACE WITH WALL-MOUNTED SPACE TEMPERATURE,
HUMIDITY, AND PRESSURE DIFFERENTIAL SENSORS, AND
ENVIRONMENTAL CONTROLLER FOR DISPLAY AND CONTROL OF
OCCUPANCY STATUS. INTERLOCK WITH DEVICES TO PROVIDE SPACE
EXHAUST AIR AND AIR TERMINAL UNIT TO MAINTAIN AIRFLOW OFFSET
AND SPACE PRESSURE DIFFERENTIAL DURING ANY CHANGE IN
SUPPLY AIRFLOW. COORDINATE EXACT LOCATIONS OF
WALL-MOUNTED DEVICES WITH THE VA.
2. LOCATE ENVIRONMENTAL CONTROL PANEL WITHIN LINE OF SIGHT OF
ENTRANCE TO ISOLATION ROOM.
3. LOCATE DEHUMIDIFIER WITHIN THE CEILING SPACE ABOVE THE DOOR
OF THE RESTROOM.
4. ALL ATU BOXES SHALL BE LOCATED WITHIN LAYIN CEILING AREAS.
5. PROVIDE FIRE/SMOKE DAMPER AT RATED WALLS. FIRE/SMOKE
DAMPERS TO REQUIRE 120V POWER AND 24V SIGNAL FROM FAP.
COORDINATE WITH DIVISION 26 & 28 CONTRACTOR FOR FINAL
CONNECTIONS.
6. CONTRACTOR TO COORDINATE WITH V.A. ADMINISTRATION TO
ENSURE EXISTING EXHAUST FAN IS OPERATIONAL.
7. EXHAUST DUCTED INTO EXISTING EXHAUST CHASE. TYPICAL.
8. EXHAUST DUCTED UP INTO EXISTING EXHAUST CHASE AT FLOOR
ABOVE. PROVIDE FSD AT CHASE PENETRATION.
9. ALL THERMOSTATS SHALL BE MERCURY FREE.
10. DURING CONSTRUCTION, NO REFRIGERANT SHALL BE DISCHARGED
AT ANY TIME.
XXXXXXXXXXXXXXXXXXXX RENOVATION KEYNOTES
44 TYP.YP 55TYP.
TYP.
J K P Q R R.4M.3K.8
10.8
J.9
10.5
9.5
8.8
9.8
Stair S7-6
Prep/Recovery
C702CC
Prep/Recovery C702I
Prep/Recovery
C702HH
Prep/Recovery
C702GC702G
Prep/Recovery C702F
Prep/Recovery C702E
Prep/Recovery
C702DD
Prep/Recovery C702B
Sterile Supply C711
Clean Linen C710
Elec E72
Comm T72
Elec C713
Toilet C705
Prep/Recovery
C702NN
Prep/Recovery
C702MC702M
Prep/Recovery C702L
Prep/Recovery
C702KK
Prep/Recovery C702J
Nurse Manager
C707
Storage C712
Soiled Utility C706
Staff Lounge/ Lockers
B732
Elece
B732AB732
Toilet C703C703
Isolation
C702AA
Nurse Station C708
Toilet C704
HAC
C709
Prep Recovery
Area C702
Corridor C7-3-1
Corridor C7-8-1
1-ATU66-0111111111
1-ATU66-02
1-ATU66-03U6
1-ATU66-04
1-ATU66-051 ATUU66 055
1-ATU66-06-
1-ATU66-076111---AAAAAAA
1-ATU66-08 1-ATU66-09 1-ATU66-10 1-ATU66-11
1-ATU66-12
1-ATU66-13 1-ATU66-14 1-ATU66-15
1-ATU66-16 1-ATU66-17 1-ATU66-18 1-ATU66-19 1-ATU66-20
y
P
1 1/2" HHWR
1 1/2" HHWS
1" HHWSH WWWWWWWWWWWWWWWWWWWWWSWWWWWSWWSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSWWWW1111111111111111111111111111111111
1" HHWRH
3/ 4"
H H
W
SS
3/ 4"
H H
W R
1/
4" H
H W
S
1/
4" H
H W
R y P
3/ 4"
H H
W S
3/ 4"
H H
W R
1-ATU66-21
3/4" HHWS TYP.W
3/4" HHWR TYP.W
1 1/4" HHWR
1 1/4" HHWS
3/4" HHWSHH
3/4" HHWRHHHH
ery
RECOVERY
C709
RECOVERY
C710
PATIENT ROOM
C711
C711A C710A C709A
OUTPATIENT RECOVERY
C707
C707A
Comm T72
Elec E72
Elec C713
LOUNGE
C706
LINEN
C705
PROGRAM MANAGER
C705B
NURSE MANAGER
C704B
ENGINEERING STORAGE
B732
SOILED UTILITY
C702
OFFICE
C703
FOYER
C704
C706AC705A
SUPPLY
C712
Toilet B701
E
A07ACCA 706C7C
E
OY
C7
OYE
C
Y
C7 5A CC7 6A 7CC 077A
C O
7040047 O
YERE
C707 AA 707C7C7 6AA C7CCCC 7AA777A
FFFFF R
C711A7 AC 1
79392 Ryan E. Morriss, PE
KEY PLAN
COA # 8304 Project # 2016627
550 North Reo Street Suite 203, Tampa, FL 33609 813.289.4700
A R C H I T E C T SJ O H N P O E
3131 NEWMARK DRIVE
SUITE 200
MIAMISBURG, OHIO 45342
937 461 3290 PHONE
jpa@johnpoe.com
1. REMOVE EXISTING MECHANICAL PIPING BACK TO BRANCH MAIN OR AS
INDICATED. CAP PIPING TO MATCH EXISTING.
2. CONTRACTOR TO FIELD DETERMINE SIZE, LOCATION, CONDITION, AND
MATERIAL TYPE OF THE EXISTING HOT WATER HYDRONIC PIPING. REPAIR
AS NEEDED.
A. ALL SERVICE INTERRUPTIONS TO THIS EXISTING FACILITY MUST BE
SCHEDULED AT LEAST 3 WEEKS IN ADVANCE AND BE KEPT TO A MINIMUM.
COORDINATE ALL DISRUPTIVE WORK AND OUTAGE REQUIREMENTS WITH
THE COR.
B. EXISTING EQUIPMENT, PIPING, DUCTWORK, DIFFUSERS, GRILLES, AND
ASSOCIATED COMPONENTS SHOWN ON DRAWINGS ARE APPROXIMATE
LOCATIONS AND IS PROVIDED FOR REFERENCE USE ONLY. FIELD VERIFY
AND COORDINATE WITH EXACT LOCATIONS, ELEVATIONS, SIZES, AND
CONDITIONS OF EXISTING COMPONENTS.
C. PROVIDE MERCURY FREE THERMOSTAT AT 48" AFF WITH VENTILATED COVER
AS DIRECTED.
D. CONTRACTOR SHALL PROVIDE A PERMANENT/PROFESSIONAL LABEL FOR
EACH (AHU, ATU) AND ASSOCIATED THERMOSTAT(S) AND TEMPERATURE
SENSOR(S).
E. ALL TERMINAL UNITS ABOVE CEILING REQUIRE FACTORY FABRICATED
ACCESS PANELS. COORDINATE WITH ARCHITECT FOR CEILING TYPE.
F. CONTRACTOR SHALL REFER TO ALL DETAILS FOR PROPER GUIDANCE.
G. CONTRACTOR SHALL PROPERLY SEAL CAULK ALL PENETRATIONS THRU FIRE
RATED/SMOKE RATED/FIRE SMOKE RATED WALLS. (PER CODE)
H. HOT WATER PIPES INTERNAL TO BUILDING SHALL BE INSULATED WITH 3/4"
THICK FIBERGLASS INSULATION.
XX
GENERAL NOTES
DEMOLITION KEYNOTES
Scale: 1/8" = 1'-0"1 SEVENTH FLOOR PLAN - MECHANICAL PIPING
Scale: 1/8" = 1'-0"2 SEVENTH FLOOR DEMOLITION PLAN - MECHANICAL PIPING
11TYP.
1. PERFORM TEST AND BALANCE OF HEATING HOT WATER SYSTEM AND
BALANCE AIR TERMINAL UNIT WATER COIL TO SCHEDULED VALUES.
2. PROVIDE SHUT OFF VALVES FOR SUPPLY AND RETURN HEATING HOT
WATER AT ALL ATU'S.
3. CONNECT NEW TO EXISTING. FIELD VERIFY EXISTING SIZE AND LOCATION.
XXXXXXXXXXXXXXXXXXXX RENOVATION KEYNOTES
22TYP.
11 TYP.TTYPT PP