ADDENDUM 1 - DRAWINGS 508-22-104.pdf
PDF 2 MB Posted
- Attached to
- Cancelled | 508-22-104 | Upgrade PACS System
- Solicitation number
- 36C24726R0096
About this file
This document is a set of Electronic Door Controls (EDC) Schedules with general notes, security symbols, technology symbols, and abbreviations for a federal medical facility project at Atlanta VA Medical Center in Decatur, Georgia.
The schedules specify electronic door control requirements across multiple floors and rooms throughout the facility, organized by floor level and room designation. Each schedule details door opening numbers, control locks specifications, request-to-exit functionality, door monitoring sensors, automatic door operators, and associated hardware requirements. Standard configurations include 24-volt power systems, DPDT (double-pole double-throw) relay contacts, and integrated fire alarm intercom push button and intrusion alarm interfaces. The document establishes uniform mounting heights for wall-mounted devices (46 inches unless noted), ceiling-mounted detectors (90 inches standard), conduit sizing requirements (1.25 inches minimum), and coordination protocols with other building trades. Security device symbols are defined for card readers, keypads, biometric readers, panic/duress buttons, motion detectors, door position switches, and request-to-exit switches, all connected to junction boxes routed through accessible ceiling plenums per Division 26 specifications. Technology symbols indicate electronic door control interfaces, data outlets (18 inches mounting height), and conduit sleeve assemblies. General requirements mandate conduit installations with pull strings, proper firestopping at wall penetrations, coordination with reflected ceiling plans and structural members, staggered outlet placement to prevent sound transmission, and finish painting of exposed conduits. All existing ceiling tiles must be reinstalled, and scheduling coordination is required with the construction phasing sequence outlined in architectural specifications.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T2
B T2
DETAIL: B = DETAIL DESIGNATION
T2 = SHEET WHERE DETAIL IS LOCATED
SECTION: 1 = SECTION DESIGNATION
T2 = SHEET WHERE SECTION IS LOCATED
PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN.
DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.
GENERAL FLOOR PLAN NOTES
CONDUIT RUN IN WALL OR ABOVE CEILING PER DIV 26.
CONDUIT RUN IN SLAB OR UNDERGROUND PER DIV 26.
CABLE MANAGEMENT SYSTEM PATHWAY PER DIV 27 / DIV 28.
LADDER TRAY PER DIV 26, 12" x 4" DEEP UNLESS NOTED OTHERWISE.
CM
SECURITY SYMBOLS
MD CEILING MOUNTED MOTION DETECTOR.
PB DESK MOUNTED PUSH BUTTON FOR LOCAL ELECTRONIC DOOR RELEASE.
GLASS BREAK.GB
PP DESK MOUNTED PANIC/DURESS BUTTON.
SECURITY SYMBOLS WITH ELECTRICAL REQUIREMENTS
DM
DOOR POSITION SWITCH WITH WIRING PER DIV 28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. PROVIDE ONE CONTACT FOR EACH LEAF IN MULTI-DOOR
OPENINGS. REFER TO SECURITY ROUGH-IN DETAILS.
RX
REQUEST TO EXIT SWITCH IN DOOR HARDWARE BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITY
ROUGH-IN DETAILS.
CR
WALL MOUNTED PROXIMITY CARD READER (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. CARD READER AND CABLING PER DIV 28. REFER
TO SECURITY ROUGH-IN DETAILS.
KC WALL MOUNTED COMBINATION KEYPAD/CARD READER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. DEVICE AND CABLING PER DIV 28.
K WALL MOUNTED SECURITY KEYPAD ENTRY STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. KEYPAD AND CABLING PER DIV 28.
MD WALL MOUNTED MOTION DETECTOR (90" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. MOTION DETECTOR, WALL MOUNT HARDWARE, AND CABLING PER DIV 28.
PP W
WALL MOUNTED PANIC/DURESS BUTTON (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO
ABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.
BR
WALL MOUNTED BIOMETRIC READER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. READER AND CABLING PER DIV 28. REFER TO
SECURITY ROUGH-IN DETAILS.
MD
PB W
WALL MOUNTED PUSH BUTTON FOR LOCAL ELECTRONIC DOOR RELEASE (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.
CEILING MOUNTED MOTION DETECTOR. 1-GANG BOX MOUNTED IN CEILING PER DIV 26. DETECTOR AND CABLING PER
DIV 28.
TECHNOLOGY SYMBOLS WITH ELEC. REQUIREMENTS
CONDUIT SLEEVE / FIRE RATED SLEEVE ASSEMBLY THRU WALL (1-2" SLEEVE UNLESS NOTED OTHERWISE) PER DIV 26.
4"
4"
CABLE TRAY PER DIV 26, 12" x 4" DEEP UNLESS NOTED OTHERWISE.
NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT
TO MODIFICATIONS ON OTHER DRAWINGS.
ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT
NECESSARILY BE USED ON THIS PROJECT.
T2 1 ELEVATION: 1 = ELEVATION DESIGNATION
T2 = SHEET WHERE ELEVATION IS LOCATED
EDC
X ELECTRONIC DOOR CONTROL. SUBSCRIPT "X" INDICATES SPECIFIC DOOR. REFER TO ELECTRONIC DOOR CONTROL
SCHEDULE FOR REQUIREMENTS.
WALL MOUNTED DATA OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT(S) TO ABOVE CORRIDOR CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" DESIGNATES QUANTITY OF DATA
CABLES. REFER TO FACEPLATE DETAILS.
X
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
RE-SUPPORT ANY EXISTING WIRING OR CONDUITS TO REMAIN.
REMOVAL PLANS MAY NOT NECESSARILY SHOW ALL ITEMS REQUIRED TO BE REMOVED.
EACH BIDDER SHALL VISIT THE SITE PRIOR TO BID TO DETERMINE THE FULL EXTENT OF
REMOVALS REQUIRED. MAINTAIN FUNCTIONALITY OF EXISTING TELECOMMUNICATIONS
SYSTEMS CUT OFF BY REMOVALS.
THE EXISTING CEILING SPACES MAY CONTAIN NUMEROUS EXISTING OPEN-WIRED CABLES
SERVING TELPHONE, CCTV, INTERCOM, DATA, PAGING, ETC. WHICH PRESENTLY LAY
DIRECTLY ON THE EXISTING CEILINGS. THESE CABLES SHALL BE TEMPORARILY SUPPORTED
FROM THE STRUCTURE TO ALLOW FOR THE REMOVAL AND / OR REPLACEMENT OF THE
EXISTING CEILINGS.
COORDINATE WITH THE OWNER IN REGARD TO REMOVALS. SALVAGE EQUIPMENT AS
DIRECTED BY THE OWNER AND STORE IN A LOCATION DESIGNATED BY OWNER. ALL OTHER
EQUIPMENT AND MATERIALS NOT SALVAGED SHALL BE REMOVED FROM THE PREMISE.
ALL CONDUITS AND TELECOMMUNICATIONS CABLING LOCATED INSIDE DEMO WALLS SHALL
BE REROUTED TO INSURE A COMPLETE AND FUNCTIONAL SYSTEM WHILE ACCOMMODATING
THE WALL REMOVAL.
REFER TO THE ARCHITECTURAL DOCUMENTS FOR CONSTRUCTION PHASING SEQUENCE.
ALL ABANDONED EXTRANEOUS CONDUITS AND SUPPORTS SHALL BE REMOVED.
REMOVALS OF TELEPHONE / DATA OUTLETS INCLUDE REMOVAL OF THE DEVICE, BACKBOX,
CONDUIT AND CABLING BACK TO THE POINT OF ORIGINATION.
REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF CASEWORK, DESKS, AND
OTHER ITEMS PLACED ON OR NEAR WALLS. DEMO, PATCH AND REPAIR EXISTING WALLS AS
REQUIRED FOR INSTALLATION OF BOXES, CONDUIT, AND WALL PENETRATIONS.
EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS
AND FIELD INVESTIGATION.
ALL EXISTING CONDUIT, EQUIPMENT, AND DEVICES SHOWN DASHED SHALL BE REMOVED.
REMOVE ALL INCIDENTAL ITEMS ASSOCIATED WITH THE DEMOLITION WORK.
GENERAL DEMO NOTES
ABBREVIATIONS
AAP - AREA ALARM PANEL - MEDICAL GAS
ACC - ACCESS
ADJ - ADJUSTABLE
AF - ARC FAULT CIRCUIT INTERRUPTER
AFCI - ARC FAULT CIRCUIT INTERRUPTER
AFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEM
AFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEM
ALT - ALTERNATE
AP - ACCESS PANEL
APPROX - APPROXIMATE
ARCH - ARCHITECT OR ARCHITECTURAL
ASSY - ASSEMBLY
ATS - AUTOMATIC TRANSFER SWITCH
BLDG - BUILDING
BOE - BOTTOM OF EQUIPMENT
BOT - BOTTOM
BTWN - BETWEEN
CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CKT - CIRCUIT
CLG - CEILING
CMU - CONCRETE MASONRY UNIT
CONN - CONNECT OR CONNECTION
CONTR - CONTRACTOR
CORR - CORRIDOR
CTR - CENTER
D - DEPTH
DET - DETAIL
DIA - DIAMETER
DIM - DIMENSION
DIV - DIVISION
DN - DOWN
DWG - DRAWING
EA - EACH
EC - ELECTRICAL (DIVISION 26)
EJ - EXPANSION JOINT
ELEC - ELECTRICAL
ELEV - ELEVATION OR ELEVATOR
EM - EMERGENCY
EQ - EQUAL
EQS - EQUIPMENT SUPPLIER
EQUIP - EQUIPMENT
ETR - EXISTING TO REMAIN
EX - EXISTING
EXP - EXPANSION
EXR - EXISTING TO BE REPLACED
EXT - EXTERIOR
FCE - FIRE CONTROL EQUIPMENT
FF - FINISHED FLOOR ELEVATION
FLR - FLOOR
FS - FIRE SUPPRESSION (DIVISION 21)
FT - FEET
FTG - FOOTING
GC - GENERAL (DIVISION 01)
GF - GROUND FAULT CIRCUIT INTERRUPTER
GFCI - GROUND FAULT CIRCUIT INTERRUPTER OR GOVERNMENT
FURNISHED CONTRACTOR INSTALLED
GFFT - GROUND FAULT FEED THRU
HC - HVAC (DIVISION 23)
HP - HORSE POWER OR HIGH POINT
HVAC - HEATING, VENTILATING, AND AIR CONDITIONING
ID - INSIDE DIAMETER
IDS - INTRUSION DETECTION SYSTEM
IN - INCHES
KE - KITCHEN EQUIPMENT
L - LENGTH
LBS - POUNDS
MAP - MASTER ALARM PANEL (MEDICAL GAS)
MAX - MAXIMUM
MEZZ - MEZZANINE
MFR - MANUFACTURER
MH - MANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEM
MIN - MINIMUM OR MINUTE
MISC - MISCELLANEOUS
MTD - MOUNTED
MTG - MOUNTING
NIC - NOT IN CONTRACT
NOM - NOMINAL
NTS - NOT TO SCALE
OD - OUTSIDE DIAMETER
OFCI - OWNER FURNISHED CONTRACTOR INSTALLED
OFOI - OWNER FURNISHED OWNER INSTALLED
PC - PLUMBING (DIVISION 22)
PLBG - PLUMBING
RAD - RADIUS
REC - RECESSED
REQD - REQUIRED
RI - ROUGH-IN
S - SURFACE MOUNTED
SC - SECURITY (DIVISION 28)
SCH - SCHEDULE
SHT - SHEET
SMS - SECURITY MANAGEMENT SYSTEM
SPEC - SPECIFICATIONS
SQ - SQUARE
SS - STAINLESS STEEL
STD - STANDARD
STRUC - STRUCTURAL OR STRUCTURE
SUC - SITE UTILITY CONTRACTOR
TC - TECHNOLOGY (DIVISION 27)
TEMP - TEMPERATURE
TGBB - TELECOM GROUNDING BUS BAR
TOE - TOP OF EQUIPMENT
TYP - TYPICAL
UNO - UNLESS NOTED OTHERWISE
VFD - VARIABLE FREQUENCY DRIVE
VOL - VOLUME
W/ - WITH
W/O - WITHOUT
WP - WEATHERPROOF
ZVC - ZONE VALVE CABINET
DATA CABLING COLOR CODE
CABLE JACKET JACK USAGE
YELLOWYELLOW
PINKPINK
BLUEBLUE
GREYGREY
GREENGREEN
REDRED
PURPLEPURPLE
WHITEWHITE
WIFI - VA
WIFI - PUBLIC
GENERAL DATA
EVIDION PATIENT MONITOR
MEDICAL
SECURITY
NURSE CALL
PLAIN OLD TELEPHONE SYSTEM (POTS)
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
CONDUITS SHALL BE SIZED FOR 1.25” MINIMUM.
ALTERNATIVE ROUTES MAYBE UTILIZED, WHICH ARE COORDINATED WITH OWNER AND OTHER
TRADES. FINAL ROUTING OF TELECOMMUNICATIONS CABLING SHALL BE APPROVED BY
OWNER/ENGINEER.
ALL JUNCTION BOXES ARE TO BE FLUSH MOUNTED UNLESS OTHERWISE NOTED.
NEW SYSTEM WIRING FOR STRUCTURED CABLING WILL BE IN CONDUIT TO THE CABLE TRAY THEN
OPEN RUN.
SLEEVE(S) AND FIRESTOP ALL NEW PENETRATIONS THRU WALLS.
VERIFY EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH REFLECTED CEILING PLAN
AND/OR ARCHITECT PRIOR TO ROUGH-IN. COORDINATE LOCATIONS OF CEILING MOUNTED
DEVICES WITH LIGHT FIXTURES, MECHANICAL DUCTS, AND SPRINKLER PIPES AND HEADS
BEFORE ROUGH-IN TO PREVENT CONFLICTS.
REMOVE EXISTING CEILING TILES AS REQUIRED FOR INSTALLATION OF NEW TECHNOLOGY ITEMS
AND REINSTALL TILES IN A SIMILAR MANNER AS NOW EXISTS.
COORDINATE EXACT LOCATION OF ALL SWITCHES, RECEPTACLES, DATA OUTLETS, ETC. WITH
RESPECTIVE CONTRACTORS PRIOR TO ROUGH-INS. ALL MOUNTING HEIGHTS OF DEVICES WHICH
ARE MOUNTED ADJACENT TO EACH OTHER SHALL BE AT THE SAME DISTANCE MEASURED ABOVE
THE FINISHED FLOOR.
STAGGER RECEPTACLES AND OTHER RECESSED OUTLETS WHEN LOCATED ON OPPOSITE SIDES
OF PARTITION / WALL TO ELIMINATE SOUND TRANSMISSION FROM ONE SPACE TO THE OTHER.
WHERE DEVICES ARE MOUNTED IN AREAS WHERE THERE ARE EXSPOSED CEILINGS,
COORDINATE THE EXACT MOUNTING / LOCATION WITH THE STRUCTURAL SUPPORT MEMBERS
AND WORK OF OTHER TRADES. PROVIDE ALL NECESSARY LABOR AND MATERIALS TO ACHIEVE
MOUNTING HEIGHTS AND LOCATIONS AS INDICATED ON THE PLANS.
REFER TO ARCHITECTURAL SPECIFICATIONS AND DOCUMENTS FOR CONSTRUCTION PHASING
SEQUENCE.
ANY EXPOSED CONDUITS WITHIN THE FINISHED PORTIONS OF THE BUILDING SHALL BE PRIMED
AND FINISH PAINTED.
ALL EMPTY CONDUITS SHALL BE INSTALLED WITH PULL STRING.
DEMO, PATCH AND REPAIR EXISTING WALLS AS REQUIRED FOR INSTALLATION OF BOXES,
CONDUIT, AND WALL PENETRATIONS.
WHERE EXISTING WALLS ARE FURRED ON ONE SIDE, ALL NEW SERVICES SHALL BE INSTALLED IN
THE WALL FROM THE FURRED OUT SIDE OF THE WALL.
EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS AND
FIELD INVESTIGATION.
ALL CONDUIT SLEEVES AND PATHWAYS SHOWN ON BID DOCUMENTS SHALL BE PROVIDED. ALL
CONDUIT SLEEVES THRU WALLS AND FLOORS, NOT SPECIFICALLY SHOWN ON DRAWINGS BUT
REQUIRED FOR COMPLIANT INSTALLATION OF CABLING SHALL BE PROVIDED AS PART OF THE
SCOPE OF WORK.
COMPLETELY AND THOROUGHLY COORDINATE ALL PATHWAYS BEING PROVIDED. ANY PATHWAYS
THAT ARE PROVIDED THAT CAUSE CABLING INSTALLATION TO BE NON-COMPLIANT SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE INSTALLATION OF CABLING.
A 3.5" DEEP MASONRY BOX SHALL BE USED IN CMU WALLS.
BOND ALL CABLE RUNWAY SPLICES AND BUTT JOINTS WITH #6 AWG BOLTED TO CABLE RUNWAY.
REMOVE PAINT OFF OF CABLE RUNWAY FOR METAL TO METAL CONNECTION AND APPLY ANTI-
OXIDANT JOINT COMPOUND OVER ANY REMAINING AREAS WITH BARE METAL EXPOSED.
ALL CONDUITS SHALL HAVE COMPRESSION FITTING OR NYLON BUSHINGS INSTALLED.
PULL BOXES SHALL NOT BE USED TO CHANGE DIRECTION AND SHALL BE INSTALLED IN LINE WITH
CONDUIT.
ALL TECHNOLOGY CONDUITS SHALL UTILIZE TELECOM SYSTEM GROUND FROM CONDUIT TO
CABLE TRAY THEN BACK TO TGBB.
X. CEILING TILES SHALL BE RETURNED TO THEIR ORIGINAL LOCATION AT THE END OF EACH SHIFT
FOR WORK AREAS OUTSIDE OF THE RATED CONSTRUCTION BARRIER. IF THE TILES CANNOT BE
RETURNED TO THEIR ORIGINAL LOCATION, THE SPRINKLER SYSTEM WILL BE CONSIDERED OUT
OF SERVICE AND A 1-HOUR FIRE SEPARATION WILL BE REQUIRED BETWEEN THE CONSTRUCTION
AREA AND THE OCCUPIED PORTIONS OF THE BUILDING.
GENERAL NOTES
CR EL
ELEVATOR CAB MOUNTED CARD READER. READER TO BE INSTALLED IN ELEVATOR CAB AS COORDINATED WITH ELEVATOR CONTRACTOR. WIRING FROM CAB THRU TRAVELING CABLE TO ELEVATOR CONTROLLER IN ELEVATOR MACHINE ROOM AND INTERFACE WITH ELEVATOR CONTROLLER AND SMS PER DIV 28, COORDINATE WITH ELEVATOR
CONTRACTOR. REFER TO SECURITY ROUGH-IN DETAILS.
CR EXR
WALL MOUNTED PROXIMITY CARD READER EXISTING TO BE REPLACED (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. CARD READER AND
CABLING PER DIV 28. REFER TO SECURITY ROUGH-IN DETAILS.
KC
WALL MOUNTED COMBINATION KEYPAD/CARD READER EXISTING TO REPLACE (46" MH UNLESS NOTED OTHERWISE). 2- GANG BOX WITH 0.75" CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. DEVICE AND
CABLING PER DIV 28.EXR
FLAME RESISTANT X"X"X" BACKBOARD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ATLANTA VA
MEDICAL
CENTER
Au to de sk
D oc s:
//A tla nt a
VA
U pg ra de C
C
TV
P
AC
S/
-0
-T
-C en tra l.r vt 8/
/2
1:
:3
PM
TN000
TECHNOLOGY LEGEND &
GENERAL NOTES
04/06/2026 JDK GES
UPGRADE PHYSICAL ACCESS
CONTROL SYSTEM
508-22-104
DECATUR, GEORGIA
BID DOCUMENTS
REVISION 1 1
Approved: Owner
No. Revisions: Date:
0 CONSTRUCTION DOCUMENTS 02/05/2025
1 BID DOCUMENTS REVISION 1 04/06/2026
3 ADDENDUM 01 08/24/2026
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ATLANTA VA
MEDICAL
CENTER
Au to de sk
D oc s:
//A tla nt a
VA
U pg ra de C
C
TV
P
AC
S/
-0
-T
-C en tra l.r vt 8/
/2
1:
:3
PM
TN600
EDC SCHEDULES
04/06/2026 JDK GES
UPGRADE PHYSICAL ACCESS
CONTROL SYSTEM
508-22-104
DECATUR, GEORGIA
BID DOCUMENTS
REVISION 1 1
Approved: Owner
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM BA102
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
R M
P O
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
1 1C299 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BA102 1
2 BA102 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BA102 1
3 BA102 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BA102 1
4 BA103 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BA102 1
5 BA103 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BA102 1
6 BA104 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BA102 1
7 BA104 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BA102 1
369 1C299 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BA102 2
465 BA101 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BA102 2
Grand total: 9
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM BC101
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
8 BC115 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 1
9 BC117 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
10 BC115 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 1
11 BC110 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
12 BC114 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
13 BC120 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 1
14 BC105 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
15 BC109 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
16 BCB01 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
17 BC106B ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
18 BCB05 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
19 BC106D ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 1
20 BC106C ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 1
21 BC101 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 2
22 BC100 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 1
23 BC106G ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 1
24 BC106 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 1
97 BCB05 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 BC101 2
98 BC103 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 BC101 2
446 BC114 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
447 BC115A ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
448 BC115 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
449 BC115 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
450 BC116 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
451 BC116 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
452 BC116 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
453 BC117B ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
454 BC117B ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
455 BC119 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
456 BC119 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 BC101 2
Grand total: 30
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM GA42A
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
35 GA101 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA42A 1
36 GA200 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
37 GA200B ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
38 GA209 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
39 GA206A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
40 GA CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA42A 1
41 RCCG55R ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
42 GA42A ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA42A 1
43 GA241 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
44 GA CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA42A 1
45 GA238 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
46 GA238B ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
47 GA CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA42A 1
48 GA STAIR NO. 8 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
49 GA EXIT ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
408 GA102 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA42A 1
457 GA236 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GA42A 2
Grand total: 17
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM GA137
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
25 164A ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA137 1
26 GA188 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA137 1
27 GA189 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA137 2
28 GA137 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA137 1
29 GA138 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA137 1
30 GA145A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA137 1
31 GA147 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA137 1
32 GA148 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA137 1
33 LOBBY GA 1 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA137 1
34 LOBBY GA 1 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA137 2
370 GA125 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GA137 2
371 GA105A CORRIDOR ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA137 2
372 GA107 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GA137 2
461 GA153A ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GA137 2
462 GA153C ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GA137 2
463 GA153B ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GA137 2
464 GA153B ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GA137 2
Grand total: 17
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM GB106
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR
PUSHPLAT
E
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
50 GB STAIR NO. 3 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
51 GB157 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GB106 1
53 GN152 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GB106 1
54 GB130 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
55 GB129 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
56 GB115 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
57 GB200 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
58 GB191 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
59 GB106 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
60 GB106 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GB106 1
61 GB105 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
62 GB104 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GB106 1
63 GB104A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 2
64 GB104A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 2
65 GB CORRIDOR RCCG31R ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GB106 1
458 GB104 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GB106 2
Grand total: 16
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM GC107
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
GC-1 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC107 1
GC342 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC107 1
52 GC345 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC107 1
69 GC233C ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC107 1
87 GC327 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC107 1
96 GC105 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC107 1
445 GC107 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC107 1
Grand total: 7
BASEMENT
GROUND FLOOR
BASEMENT
GROUND
FLOOR
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM GC129
E
D C
N U
M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
66 GC136 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC129 2
67 GC129 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC129 1
68 GC110A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC129 1
84 GC120A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC129 1
85 GC112B ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC129 1
262 GC218 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GC129 2
Grand total: 6
No. Revisions: Date:
0 CONSTRUCTION DOCUMENTS 02/05/2025
1 BID DOCUMENTS REVISION 1 04/06/2026
3 ADDENDUM 01 08/24/2026
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ATLANTA VA
MEDICAL
CENTER
Au to de sk
D oc s:
//A tla nt a
VA
U pg ra de C
C
TV
P
AC
S/
-0
-T
-C en tra l.r vt 8/
/2
1:
:4
PM
TN601
EDC SCHEDULES
04/06/2026 JDK GES
UPGRADE PHYSICAL ACCESS
CONTROL SYSTEM
508-22-104
DECATUR, GEORGIA
BID DOCUMENTS
REVISION 1 1
Approved: Owner
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM GC122A
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
70 GC124H ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC122A 1
71 GC124D ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
72 GC124I ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
73 GC124 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC122A 1
74 GC124 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC122A 1
75 GC STAIR NO. 11 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
76 GC124C ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
77 GC109H ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC122A 1
78 GC124 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC122A 1
79 GC118D ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
80 GC122G ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
81 GC109C ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
82 GC109B ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC122A 1
83 GC122A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC122A 1
86 GC118 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 GC122A 1
459 GC109D ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GC122A 2
460 GC109D ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 GC122A 2
Grand total: 17
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM GC331
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
88 GC331 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
89 GC331G ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
90 GC331 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
91 GC331A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
92 GC331A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
93 GC331A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
94 GC331C ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
95 GC345 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
105 GC331B ● ● 24 ● 1 ● ● 1 DPDT ● ● 0 0 0 0 GC331 1
Grand total: 9
FIRST
FLOOR A
GROUND FLOOR
FIRST
FLOOR A
GROUND
FLOOR
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1A209
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
126 1A229 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A209 1
127 1A228 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A209 1
129 1A209 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A209 1
130 1A-6 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A209 1
131 1A-5 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A209 1
Grand total: 5
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1A146
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
99 1A146 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
100 1A145 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A146 1
101 1A104C ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
102 1A104B ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
103 1A104A ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A146 1
104 1A-3 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A146 2
106 1A104D ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
107 1A104E ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A146 1
108 1A105A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
109 1A137 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A146 1
110 1A136 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
111 1A133A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
112 1A116 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
113 1A109 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
114 1A116 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
115 1C237 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A146 1
510 1A147 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A146 2
Grand total: 17
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1A111
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
116 1A112 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A111 1
117 1A111 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A111 1
118 1A109 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A111 1
119 1C178C CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A111 1
120 1A102 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A111 1
121 1A101 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A111 1
122 1A CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A111 1
123 1A-1 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A111 1
124 1A CORRIDOR ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1A111 1
125 1C256E ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1A111 2
Grand total: 10
No. Revisions: Date:
0 CONSTRUCTION DOCUMENTS 02/05/2025
1 BID DOCUMENTS REVISION 1 04/06/2026
3 ADDENDUM 01 08/24/2026
3 3
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ATLANTA VA
MEDICAL
CENTER
Au to de sk
D oc s:
//A tla nt a
VA
U pg ra de C
C
TV
P
AC
S/
-0
-T
-C en tra l.r vt 8/
/2
1:
:4
PM
TN602
EDC SCHEDULES
04/06/2026 JDK GES
UPGRADE PHYSICAL ACCESS
CONTROL SYSTEM
508-22-104
DECATUR, GEORGIA
BID DOCUMENTS
REVISION 1 1
Approved: Owner
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3. RCC150R INTERLOCKS WITH RCC149R FOR LOCATION SEE SHEET 1-TN113C4
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1C250
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
163 1C250 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C250 1
164 1C CORRIDOR ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C250 1
165 1C334 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C250 2
166 1C CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C250 1
167 1C486 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C250 1
168 1C167 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C250 1
169 1C452 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C250 1
171 1C519 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C250 1
172 1C507 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C250 1
173 RCC150R ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C250 3
174 1B600 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C250 1
470 1C385 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C250 2
Grand total: 12
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1C440
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
132 1B335 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 1
141 1C363A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 2
170 1C440 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 1
175 1C418 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 1
176 1C416 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 2
177 1C CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C440 1
178 1C259 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C440 1
179 1C257B ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C440 1
180 1C266 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 1
181 1C408 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 1
182 1C406 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 1
183 1C441 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 1
184 1C415A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C440 2
413 1C257C CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C440 2
428 1C257C CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C440 2
473 1C257B ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C440 2
474 1C271 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C440 2
475 1C272 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C440 2
Grand total: 18
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1B509
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
128 1B200 ● ● 24 ● 1 ● ● 1 DPDT ● ● 0 0 0 0 1B509 2
133 1B335C ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B509 1
136 1B298A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B509 1
137 1B509 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B509 1
138 1B STAIR NO.2 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B509 1
139 1B STAIR NO.1 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B509 1
140 1B520 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B509 1
200 2B520 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B509 1
471 1B519 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1B509 2
472 2B509 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1B509 2
Grand total: 10
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1C179A
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
157 1C179A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C179A 1
158 1C181A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C179A 1
160 1C601G ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C179A 1
161 1C150B ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C179A 1
162 1C150 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C179A 1
376 1C153V CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C179A 1
377 1C601 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C179A 1
378 1C601B ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1C179A 1
412 1C560A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1C179A 2
433 1C156 ● ● 24 ● 1 ● ● 1 DPDT ● ● 0 0 0 0 1C179A 1
476 1C181D ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C179A 2
477 1C178A CORRIDOR ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C179A 2
478 1C600 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C179A 2
479 1C153U ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C179A 2
480 1C558 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C179A 2
511 1C220N ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1C179A 2
Grand total: 16
FIRST FLOOR C
FIRST FLOOR B
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1B157
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P# T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
134 1B335 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B157 1
135 1B310 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B157 1
142 1B157 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B157 2
149 1B145 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B157 1
429 1B-1A CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B157 2
430 1B-3 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B157 1
468 1B312 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1B157 2
469 1B157 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1B157 2
Grand total: 8
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 1B160D
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
143 1B160D ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
144 1B170K ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
145 1B160I ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
146 1B170A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 2
147 1B170K ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
148 1B170 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
150 1B100 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B160D 1
151 1B107 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
152 1B142 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B160D 1
153 1B139 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B160D 1
154 1B126 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 2
155 1B117 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
156 1B111 CORRIDOR ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
373 1B133A CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B160D 2
374 1B133 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B160D 2
375 1B106 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B160D 2
431 1B-1 CORRIDOR ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 1B160D 1
432 1B-2A CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 1B160D 1
466 1B121 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1B160D 2
467 1B127 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 1B160D 2
Grand total: 20
FIRST
FLOOR C
FIRST
FLOOR B
No. Revisions: Date:
0 CONSTRUCTION DOCUMENTS 02/05/2025
1 BID DOCUMENTS REVISION 1 04/06/2026
3 ADDENDUM 01 08/24/2026
3 3
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ATLANTA VA
MEDICAL
CENTER
Au to de sk
D oc s:
//A tla nt a
VA
U pg ra de C
C
TV
P
AC
S/
-0
-T
-C en tra l.r vt 8/
/2
1:
:5
PM
TN603
EDC SCHEDULES
04/06/2026 JDK GES
UPGRADE PHYSICAL ACCESS
CONTROL SYSTEM
508-22-104
DECATUR, GEORGIA
BID DOCUMENTS
REVISION 1 1
Approved: Owner
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 2C129
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
390 2C220 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C129 1
391 2C-4 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
392 2C CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
393 2C270 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C129 1
394 2C286 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C129 1
395 2C271 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
396 2C129 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
397 2C CORRIDOR ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C129 1
398 2C105A CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
399 2C-3 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
400 2C184 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C129 1
401 2C280 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
405 2C CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C129 1
411 2C-1 CORRIDOR ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C129 2
Grand total: 14
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 2C207
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
388 2C211 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C207 1
389 2C207 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C207 1
402 2C170 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C207 1
403 2C175 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C207 1
404 2C-4A CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2C207 1
495 2C173 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2C207 2
496 2C400 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2C207 2
Grand total: 7
SECOND FLOOR A
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 2B137
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
204 2B103G ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2B137 1
205 2B128 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2B137 1
206 2B137 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2B137 1
207 2B136 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2B137 1
208 2B133 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2B137 1
Grand total: 5
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 2B179A
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
196 2B179A ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2B179A 1
197 2B181 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2B179A 1
198 2B188 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2B179A 1
199 2B222 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2B179A 1
201 2B227 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2B179A 1
202 2B226 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2B179A 1
203 2B103 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2B179A 1
483 2B199 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
484 2B170 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
485 2B170 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
486 2B171 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
487 2B174 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
488 2B174 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
489 2B176 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
490 2B184A ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
491 2B184B ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
492 2B184C ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
493 2B175 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
494 2B199 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
532 2B170 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2B179A 2
Grand total: 20
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
2. PROVIDE HARDWARE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 2A151A
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
191 2A151 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2A151A 1
192 2A151A ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2A151A 1
193 2A103 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2A151A 1
194 2A101 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2A151A 1
195 2A-2 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2A151A 1
444 2A-2 CORRIDOR ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2A151A 1
481 2A127 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
482 2A125 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
516 2A244 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
517 2A245 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
518 2A247A ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
519 2A229 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
520 2A159D ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
521 2A159D ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
522 2A159E ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
523 2A159 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
526 2A158B ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
527 2A149 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
528 2A158 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
529 2A159E ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A151A 2
Grand total: 20
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARWARE.
2. PROVIDE HARDWRE REQUIRED.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 2A241
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
185 2A195 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2A241 1
186 2A196 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2A241 1
187 2A185 ● ● ● ● 24 ● ● 1 ● ● ● 2 DPDT ● ● 0 0 0 0 2A241 1
188 2A182 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2A241 1
189 2A242 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2A241 1
190 2A241 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2A241 1
512 2A209 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A241 2
513 2A197 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A241 2
514 2A197 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A241 2
515 2A240 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A241 2
524 2A162 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A241 2
525 2A155 ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A241 2
530 2A197A ● ● 24 ● 1 ● ● 0 DPDT ● ● 0 0 0 0 2A241 2
531 2A183 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2A241 2
Grand total: 14
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
3.
4.
ELECTRONIC DOOR CONTROLS SCHEDULE ROOM 2C314
E D
C N
U M
BE
R
D O
O R
O
PE
N
IN
G N
U M
BE
R
CONTROL LOCKS REQUEST TO EXIT DOOR MONITOR
AUTOMATIC DOOR
OPERATOR
R O
O M
N U
M
BE
R
SCHEDULE
NOTES
EAC INTERFACE POWER TYPE
Q
TY
FUNCTION LOCATION POSITION SWITCH L BOLT
BOND
SENSOR MOTOR PUSHPLATE
R
EA
D
ER
T O
D
F
IR
E
AL
AR
M
IN
TE
R C
O M
P U
SH
B
U
TT
O N
IN
TR
U
SI
O N
A
LA
E / P
O E+
V O
LT
AG
E
L O
C
AL
R
EM
O
TE
L O
C
AT
IO
N
N O
TE
EP EL ES ML
W L A
LA
R
M S
H U
N T
U N
LO
C
K
N O
TE
H
AR
D W
AR
E
M O
TI
O
N
W
AL
L
SW
IT
C
H
N O
TE
QTY #
P#
T
B
AL
AN
C
ED
H
IG
H S
EC
U
R
IT
Y
R
EC
ES
SE
D
S U
R
FA
C E
QTY QTY QTY E
AC
IN
TE
R
FA
C E
QTY W
IR
EL
ES
S
406 2C301 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C314 1
407 2C314 ● ● ● 24 ● ● 1 ● ● ● 1 DPDT ● ● 0 0 0 0 2C314 1
Grand total: 2
SECOND FLOOR B
SECOND FLOOR B
SECOND FLOOR C
No. Revisions: Date:
0 CONSTRUCTION DOCUMENTS 02/05/2025
1 BID DOCUMENTS REVISION 1 04/06/2026
3 ADDENDUM 01 08/24/2026
3 3
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ATLANTA VA
MEDICAL
CENTER
Au to de sk
D oc s:
//A tla nt a
VA
U pg ra de C
C
TV
P
AC
S/
-0
-T
-C en tra l.r vt 8/
/2
1:
:0
PM
TN604
EDC SCHEDULES
04/06/2026 JDK GES
UPGRADE PHYSICAL ACCESS
CONTROL SYSTEM
508-22-104
DECATUR, GEORGIA
BID DOCUMENTS
REVISION 1 1
Approved: Owner
SCHEDULE NOTES:
1. REUSE EXISTING LOCKING HARDWARE.
3.
4.
ELECTRONIC…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .