36C24619B0040-008.pdf
PDF Posted
- Attached to
- 652-318 Construct Cancer Center (VA-19-00013696)
- Solicitation number
- 36C24619B0040
About this file
This solicitation seeks proposals for a construction project to build a 15,000 square foot cancer center addition at a VA medical center in Richmond, Virginia. The project is valued between $5-10 million and has a period of performance of 630 calendar days from notice to proceed. The NAICS code is 236220 with a $36.5 million small business size standard. Drawings and specifications will be provided in the solicitation, which is open only to Service-Disabled Veteran-Owned Small Businesses. Proposals are due on or around August 15, 2019 following a pre-proposal site visit. The selected contractor will provide all labor, materials, equipment, transportation and supervision to complete the project in accordance with the construction documents prepared by Miller-Remick, LLC.
36C24619B0040 S02 Architectural.pdf
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAXIMUM
MECHANICAL
MOUNTING
METAL
NOT IN CONTRACT
OPPOSITE HAND
PLASTIC LAMINATE
PAINT
PAINTED
RISER
RETURN AIR
RUBBER BASE
SEALED CONCRETE
SOLID SURFACE
SHEET VINYL
SIMILAR
STORAGE
SUSPENDED
TREAD
TOP OF BOND BEAM
TOP OF STRUCTURE
TYPICAL
VA FURNISHED
CONTRACTOR INSTALLED
VA FURNISHED
VA INSTALLED
VERTICAL
VINYL WALL COVERING
EXPANDED POLY STYRENE
AT
ANGLE
CENTER LINE
DIAMETER
ABOVE FINISH FLOOR
ACOUSTICAL TILE
ALUMINUM THRESHOLD
VINYL BASE
CUBICLE CURTAIN
CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CONTRACTOR FURNISHED
VA INSTALLED
CORNER GUARD
CEILING
COLUMN
CONCRETE
CONTINUOUS
CORRIDOR
CERAMIC TILE
ELECTRIC(AL)
ELEVATOR
EXISTING TO REMAIN
ELECTRIC WATER COOLER
EXISTING
FINISH(ED)
FACE OF FINISH
FACE OF STUD
GYSPUM WALLBOARD
HARDWARE
HOUR
HEIGHT
LENGTH
LUXURY VINYL TILE
A.F.F.
ACT
ATH.
BV
CC
CFCI
CFVA
CG
CLG
COL
CONC
CONT
CORR
CT
ELEC
ELEV
ETR
EWC
EXST
FIN
FOF
FOS
GWB
HDWR
HR
HT
L
LVT
MAX
MECH
MTG
MTL
NIC
O H
PLAM
PNT
PTD
R
RA
RB
SC
SS
SV
SIM
STOR
SUSP
T
TOBB
TOS
TYP
VACI
VAVA
VERT
WVW
XPS
O
ABBREVIATIONS
DOOR TAG
TYP.
1i
M349
ACE
EXISTING DOOR
NEW DOOR
DEMO DOOR
NEW WALL
EXISTING WALL
DEMO WALL OR ITEMS
ABOVE OR BELOW
WALL PROTECTION TAG
WALL TAG
ROOM NUMBER
REVISION TAG
EQUIPMENT TAG
TOILET ACCESSORY TAG
DEMOLITION NOTE
NEW WORK NOTE
A810
DEMO ROOM NUMBER
CURTAINWALL AND
WINDOW MARKER
1i
INTERIOR ELEVATION
MARKER
SECTION OR WALL
SECTION NUMBER
COLUMN GRID NUMBER
EXISTING COLUMN
GRID NUMBER
A120
BUILDING ELEVATION
MARKER
A810
A810 DETAIL MARKER
ARCHITECTURAL SYMBOL LEGEND
1 PHASING NOTES
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
BID DOCUMENTS
FULLY SPRINKLERED
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AG001
EXTERIOR RENDERING PREVIEWS,
ABBREVIATIONS, AND SYMBOLS
JCHDJP
11/08/18
NORTHEAST AERIAL VIEWNORTH GROUND LEVEL VIEW
SECOND LEVEL VIEW FROM DIALYSIS
WALL TYPE SCHEDULE
TYPE STC DESCRIPTION FIRE RATING UL REMARKS
C8_1 N/A
8" CMU WITH CONTINUOUS HORIZONTAL JOINT REINFORCING @
16" O.C. VERTICALY. EXTEND WALL ASSEMBLY TO DECK ABOVE
1 HR BARRIER U905
PROVIDE 3" STENCILED TEXT EVERY 8' O.C. MAX. READING "1 HR FIRE
BARRIER". PROVIDE FIRE SAFING WHERE COMPONETS MEET DECK
ABOVE.
C8_1f N/A
8" CMU, CONTINUOUS HORIZONTAL JOINT REINFORCING @ 16"
O.C. VERTICALY, 7/8" METAL FURRING CHANNEL, 5/8" GWB.
EXTEND WALL ASSEMBLY TO DECK ABOVE
1 HR BARRIER U905
PROVIDE 3" STENCILED TEXT EVERY 8' O.C. MAX. READING "1 HR FIRE
BARRIER". PROVIDE FIRE SAFING WHERE COMPONETS MEET DECK
ABOVE.
M1 h N/A
7/8" METAL HAT CHANNEL AT 16" O.C. MAX. 5/8" GWB ONE SIDE.
EXTEND WALL ASSEMBLY TO 4" ABOVE FINISHED CEILING.
N/A N/A
M1_C N/A
1 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" GWB ONE SIDE.
EXTEND WALL ASSEMBLY TO UNDERSIDE OF DECK ABOVE.
SMOKE PARTITION N/A
PROVIDE 3" STENCILED TEXT AT 8' O.C. MAX. READING "SMOKE
PARTITION". PROVIDE INSULATION WHERE COMPONENTS MEET
DECK ABOVE. PROVIDE ACOUSTICAL SEALANT AT RUNNER AND
HEAD PRIOR TO INSTALLATION OF GWB.
M1B N/A
1 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" GWB ONE SIDE.
EXTEND WALL ASSEMBLY TO 4" ABOVE FINISHED CEILING.
N/A N/A
M2B N/A
2 1/2" METAL STUDS AT 16" O.C. MAX. 5/8" GWB ONE SIDE.
EXTEND WALL ASSEMBLY TO 4" ABOVE FINISHED CEILING.
N/A N/A
M3 N/A
3 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" GWB BOTH SIDES.
EXTEND WALL ASSEMBLY TO 4" ABOVE FINISHED CEILING.
N/A N/A
M3_1 40
3 5/8" METAL STUDS AT 16" O.C.MAX. 5/8" FIRE RATED GWB BOTH
SIDES. EXTEND WALL ASSEMBLY TO UNDERSIDE OF DECK
ABOVE.
1 HR BARRIER U419
PROVIDE 3" STENCILED TEXT EVERY 8' O.C. READING "1 HR FIRE
BARRIER". PROVIDE INSULATION WHERE COMPONENTS MEET DECK
ABOVE. PROVIDE SEALANT AT RUNNER AND HEAD PRIOR TO
INSTALLATION OF GWB
M3_1C 40
3 5/8" METAL STUDS AT 16" O.C.MAX. 5/8" FIRE RATED GWB BOTH
SIDES. EXTEND WALL ASSEMBLY TO UNDERSIDE OF DECK
ABOVE.
1 HR SMOKE
BARRIER
U419
PROVIDE 3" STENCILED TEXT EVERY 8' O.C. READING "1 HR FIRE &
SMOKE BARRIER". PROVIDE INSULATION WHERE COMPONENTS
MEET DECK ABOVE. PROVIDE SEALANT AT RUNNER AND HEAD PRIOR
TO INSTALLATION OF GWB
M3_2 50
3 5/8" METAL STUDS AT 16" O.C. MAX. 2 LAYERS 5/8" FIRE RATED
GWB BOTH SIDES. EXTEND WALL ASSEMBLY TO UNDERSIDE OF
DECK ABOVE.
2 HR SMOKE
BARRIER
U419
PROVIDE 3" STENCILED TEXT EVERY 8' O.C. READING "2 HR FIRE
BARRIER". PROVIDE INSULATION WHERE COMPONENTS MEET DECK
ABOVE. PROVIDE ACOUSTICAL SEALANT AT RUNNER AND HEAD
PRIOR TO INSTALLATION OF GWB. PROVIDE ACOUSTICAL SEALANT
AT ALL WALL PENETRATIONS.
M3_C N/A
3 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" FIRE RATED GWB BOTH
SIDES. EXTEND WALL ASSEMBLY TO UNDERSIDE OF DECK
ABOVE.
SMOKE PARTITION N/A
PROVIDE 3" STENCILED TEXT AT 8' O.C. MAX. READING "SMOKE
PARTITION. PROVIDE INSULATION WHERE COMPONENTS MEET DECK
ABOVE. PROVIDE ACOUSTICAL SEALANT AT RUNNER AND HEAD
PRIOR TO INSTALLATION OF GWB.
M3B N/A
3 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" GWB ONE SIDE.
EXTEND WALL ASSEMBLY TO 4" ABOVE FINISHED CEILING.
N/A N/A
M4B N/A 4" METAL STUDS AT 16" O.C. MAX. 3/4" PLYWOOD SHEATHING N/A N/A
M6 N/A
6" METAL STUDS AT 16" O.C. MAX. 5/8" GWB BOTH SIDES.
EXTEND GWB TO 4" ABOVE FINISHED CEILING. ANCHOR STUDS
TO UNDERSIDE OF DECK OR STRUCTURE ABOVE AT 48" O.C.
MAX
N/A N/A
M340B 40
3 5/8" METAL STUDS AT 16" O.C.MAX. 5/8" GWB ONE SIDE.
PROVIDE 3" MINERAL WOOL. EXTEND WALL ASSEMBLY TO
UNDERSIDE OF DECK ABOVE
N/A N/A
PROVIDE SOUND INSULATION WHERE COMPONENTS MEET DECK
ABOVE. PROVIDE ACOUSTICAL SEALANT AT RUNNER AND HEAD
PRIOR TO INSULATION OF GWB. PROVIDE ACOUSTICAL SEALANT AT
ALL WALL PENETRATIONS.
M349 49
3 5/8" METAL STUDS AT 16" O.C.MAX. 5/8" GWB BOTH SIDES.
PROVIDE 3" SAFB CREASED MINERAL WOOL. EXTEND WALL
ASSEMBLY TO UNDERSIDE OF DECK ABOVE
N/A N/A
PROVIDE SOUND INSULATION WHERE COMPONENTS MEET DECK
ABOVE. PROVIDE ACOUSTICAL SEALANT AT RUNNER AND HEAD
PRIOR TO INSULATION OF GWB. PROVIDE ACOUSTICAL SEALANT AT
ALL WALL PENETRATIONS.
M349_1 49
3 5/8" METAL STUDS AT 16" O.C.MAX. 5/8" FIRE RATED GWB BOTH
SIDES. PROVIDE 3" MINERAL WOOL. EXTEND WALL ASSEMBLY TO
UNDERSIDE OF DECK ABOVE ABOVE.
1 HR BARRIER U419
PROVIDE 3" STENCILED WITH 3/8" STROKE TEXT EVERY 8' O.C.
READING "1 HR FIRE BARRIER. PROVIDE INSULATION WHERE
COMPONENTS MEET DECK ABOVE. PROVIDE ACOUSTICAL SEALANT
AT RUNNER AND HEAD PRIOR TO INSTALLATION OF GWB. PROVIDE
ACOUSTICAL SEALANT AT ALL WALL PENETRATIONS.
M349_C 49
3 5/8" METAL STUDS AT 16" O.C.MAX. 5/8" GWB BOTH SIDES.
PROVIDE 3" MINERAL WOOL. EXTEND WALL ASSEMBLY TO
UNDERSIDE OF DECK ABOVE
SMOKE PARTITION N/A
PROVIDE 3" STENCILED WITH 3/8" STROKE TEXT EVERY 8' O.C.
READING "SMOKE PARTITION". PROVIDE INSULATION WHERE
COMPONENTS MEET DECK ABOVE. PROVIDE ACOUSTICAL SEALANT
AT RUNNER AND HEAD PRIOR TO INSTALLATION OF GWB. PROVIDE
ACOUSTICAL SEALANT AT ALL WALL PENETRATIONS.
M355_2S 55
3 5/8" METAL STUDS AT 16" O.C.MAX. 2 LAYERS 1/2" FIRE RATED
GWB BOTH SIDES. 3" CREASED SAFB MINERAL WOOL. EXTEND
WALL ASSEMBLY TO UNDERSIDE OF DECK ABOVE.
2 HR SMOKE
BARRIER
U419
PROVIDE 3" STENCILED TEXT EVERY 8' O.C. READING "2 HR SMOKE
BARRIER. PROVIDE INSULATION WHERE COMPONENTS MEET DECK
ABOVE.
M640 40
6" METAL STUDS AT 16" O.C.MAX. 5/8" GWB BOTH SIDES.
PROVIDE 3" SAFB CREASED MINERAL WOOL. EXTEND WALL
ASSEMBLY TO UNDERSIDE OF DECK ABOVE
N/A N/A
PROVIDE SOUND INSULATION WHERE COMPONENTS MEET DECK
ABOVE. PROVIDE ACOUSTICAL SEALANT AT RUNNER AND HEAD
PRIOR TO INSULATION OF GWB. PROVIDE ACOUSTICAL SEALANT AT
ALL WALL PENETRATIONS.
M649_1 49
6" METAL STUDS AT 16" O.C.MAX. 5/8" FIRE RATED GWB BOTH
SIDES. PROVIDE 3" MINERAL WOOL. EXTEND WALL ASSEMBLY TO
UNDERSIDE OF DECK ABOVE ABOVE.
1 HR BARRIER U419
PROVIDE 3" STENCILED WITH 3/8" STROKE TEXT EVERY 8' O.C.
READING "1 HR FIRE BARRIER. PROVIDE INSULATION WHERE
COMPONENTS MEET DECK ABOVE. PROVIDE ACOUSTICAL SEALANT
AT RUNNER AND HEAD PRIOR TO INSTALLATION OF GWB. PROVIDE
ACOUSTICAL SEALANT AT ALL WALL PENETRATIONS.
SW_1 N/A
2 1/2" CH STUDS AT 24" O.C. MAX. 1" GYPSUM LINER ONE SIDE
AND 5/8" GWB OTHER SIDE SIDE. EXTEND WALL ASSEMBLY TO
DECK ABOVE.
1 HR BARRIER
U 415
SYSTEM
A
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
ARCHITEC
T
EXISTING EMERGENCY
POWER GENERATOR
EXISTING BASKETBALL COURT
EXST MRI
EXST DIALYSIS
EXST BUILDING 500
EXST MULTIPURPOSE
EXISTING RADIATION ONCOLOGY
FUTURE LINEAR
ACCELERATOR
ADDITION
EXST SERVICE ROAD
NEW WALKWAY
SEE CIVIL DRAWINGS
MECHANICAL R.T.U.
S T
A N
D O
F F
D
IS
T A
N C
E
R
STAND OFF DISTANCE
R 50' - 0"
EXISTING SECURITY FENCE
EXISTING GATE
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
BID DOCUMENTS
FULLY SPRINKLERED
ACTUAL & PLAN
NORTH
NTS
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AS110
SITE PLAN
JCHDJP
11/08/18
1" = 20'-0"
ARCHITECTURAL SITE PLAN
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
U
1Z-127
1Z-128
1Z-126
M349_1
M3_1
M1B
E0948
M9025
M4100
A1132
M4200
A5106
F2010
F0205
F0230 M1801
A1011
A5075
A5080
A5145
F3200
M3070
NIC
MIN.
6' - 0"
/8
/4
U
T
1Z-128
1Z-127
1Z-126
NIC
DC1Z-2
D1Z-126
D1Z-127
D1Z-128
U
T
TYP.
MIN.
6' - 0"
NIC
5' - 7 1/2" 2' - 11"
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
BID DOCUMENTS
FULLY SPRINKLERED
ACTUAL & PLAN
NORTH
NTS
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AD100
DEMOLITION, NEW WORK, AND
REFLECTED CEILING PLAN - LEVEL 1 -
PHASE 1
JCHDJP
11/08/18
1/4" = 1'-0"
NEW WORK - LEVEL 1 - PHASE 1
GENERAL NEW WORK NOTES - PHASE 1
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND
LOCAL CODES AND ORDINANCES.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF
CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF
THE ARCHITECT FOR A RESOLUTION.
EACH SUB CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS AND EVALUATE
THE SCOPE OF WORK REQUIRED BY THEIR RESPECTIVE TRADE AND ANY CONFLICTS WITH
OTHER TRADES. ANY CONFLICTS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR A RESOLUTION.
PROVIDE SHALL MEAN TO SUPPLY, TO FURNISH AND TO INSTALL COMPLETE WITH ALL
ACCESSORIES, PARTS AND/OR SERVICES TO BE READY FOR ITS INTENDED USE.
WHERE WORK ABUTTS OR ADJOINS EXISTING SURFACES, WHICH WILL REMAIN EXPOSED,
ALIGN NEW WORK FLUSH WITH EXISTING ADJACENT SURFACES.
CONTRACTOR SHALL COORDINATE ALL REQUIRED CONDUIT, PIPING AND CHASES FOR OWNER
FURNISHED OWNER INSTALLED EQUIPMENT WITH THE OWNER.
CONTRACTOR SHALL PROVIDE BARRIERS TO PREVENT ENTRY TO THE CONSTRUCTION AREA.
BARRIERS SHALL NOT INTERFERE WITH THE OWNERS USE OF THE SITE OR SAFE MEANS OF
EGRESS.
THE CONTRACTOR SHALL PROVIDE NEGATIVE PRESSURE IN THE AREA OF RENOVATION TO
PREVENT THE SPREAD OF DUST TO OCCUPIED AREAS OF THE BUILDING.
ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS SHEET ONLY
UNLESS OTHERWISE NOTED.
• ALL DOORS TO BE MOUNTED 6" FROM FACE OF FINISH UON.
ALL MODIFICATIONS TO THE EXISTING ROOF SHALL BE MADE IN ACCORDANCE WITH VAMC'S
EXISTING ROOF WARRANTY. COORDINATE ALL MODIFICATIONS TO THE ROOF WITH THE COR.
ALL SYMBOLS WHOSE TYPE IS NOT INDICATED ON THE SHEET CAN BE REFERENCED FROM
SHEET AG001
• SEE SHEET AG001 FOR WALL TYPE SCHEDULE.
• SEE OVERALL NEW WORK PLANS FOR EXTERIOR AND OVERALL INTERIOR DIMENSIONS
• SEE ENLARGED PLANS FOR WALL TYPE LOCATIONS AND INTERIOR DIMENSIONING
• SEE EQUIPMENT PLANS FOR INTERIOR ELEVATION LOCATIONS
CONTRACTOR SHALL COORDINATE WITH WORK BEING PERFORMED UNDER SEPARATE
CONTRACT BY VA COR.
• SEE LIFE SAFETY PLAN FOR FIRE BARRIER AND SMOKE PARTITION LOCATIONS.
• SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIGHTING AND DIFFUSER TYPES.
ALL ABUTTING DISSIMILAR MATERIALS ARE TO BE SEALED. COLOR TO MATCH ADJACENT
MATERIALS.
ROOM LEGEND - LEVEL 1 - PHASE 1
NUMBER NAME
1Z-126 HAC
1Z-127 SOILED LINEN
1Z-128 EXAM
1Z-100 CHIEF
1Z-101 SEC.
1Z-102 ADMIN. OFFICE
1Z-103 OFFICE
1Z-104 CONFERENCE ROOM
NEW WORK NOTES - LEVEL 1 - PHASE 1
1 ALIGN NEW WALL WITH ADJACENT EXISTING WALL
DENOTES TEMPORARY FIRE RATED DOOR AND ICRA HARDWALL BARRIER - 1 HR SMOKE
BARRIER. WALL TO BE: 5/8" TYPE X GWB BOTH SIDES OF 3 5/8" MTL STUDS AT 16" OC,
EXTEND TO DECK / SLAB ABOVE WITH FIRE RATED SEALANT AT TOP AND BOTTOM
CONNECTIONS ON BOTH SIDES. SEAL TIGHT AROUND ALL PENETRATIONS. REMOVE
TEMPORARY PARTIITION IN IT'S ENTIRETY AFTER THE COMLETION OF NEW WORK.
3 PROVIDE ACCENT PAINT THIS WALL, PNT #3, SEE AE603.
PROVIDE BUMPER GUARD [BG#1] TO 34" A.F.F. THIS ROOM WHERE APPLICABLE. SEE
FINISH SPECIFICATIONS FOR INFORMATION.
1/8" = 1'-0"
REFLECTED CEILNG PLAN - LEVEL 1 - PHASE 1
EQUIPMENT SCHEDULE - PHASE 1
MARK DESCRIPTION VACI VAVA CFCI COMMENTS
A1011 TELEPHONE, DESK *** PROVIDE POWER & DATA
A1132 ACCESSORY RAIL *** PROVIDE BLOCKING AS REQUIRED
A5075 SOAP DISPENSER ***
A5080 PAPER TOWEL DISPENSER ***
A5106 SHARPS DISPOSAL *** ---
A5145 ROBE HOOK ***
E0948 STORAGE CART *** ---
F0205 SIDE CHAIR WITH ARMS ***
F0230 ROTARY STOOL *** ---
F2010 BASKET, WASTEPAPER, STEP ON *** ---
F3200 CLOCK *** PROVIDE POWER
M1801 COMPUTER WITH FLAT PANEL MONITOR *** PROVIDE POWER & DATA
M3070 HAMPER, LINEN, MOBILE, W/ LID *** ---
M4100 SYPHYGMOMANOMETER *** ---
M4200 OTOSCOPE *** ---
M9025 EXAM TABLE *** PROVIDE POWER
1/4" = 1'-0"
DEMOLITION PLAN - LEVEL 1 - PHASE 1
DEMOLITION NOTES - LEVEL 1 - PHASE 1
1 REMOVE WALL AS INDICATED IN ITS ENTIRETY.
2 REMOVE WALL FINISHES, BASE, AND FLOOR FINISH THIS ROOM.
3 REMOVE DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY
4 PLUMBING FIXTURE TO BE REMOVED ENTIRELY.
5 REMOVE CEILING IN ITS ENTIRETY.
6 EXISTING PLUMBING FIXTURE TO REMAIN.
7 REMOVE PORTION OF WALL FOR NEW DOOR.
DENOTES TEMPORARY FIRE RATED DOOR AND ICRA HARDWALL BARRIER - 1 HR SMOKE BARRIER. WALL TO BE:
5/8" TYPE X GWB BOTH SIDES OF 3 5/8" MTL STUDS AT 16" OC, EXTEND TO DECK / SLAB ABOVE WITH FIRE
RATED SEALANT AT TOP AND BOTTOM CONNECTIONS ON BOTH SIDES
GENERAL DEMOLITION NOTES - PHASE 1
DEMOLITION DRAWINGS INDICATE IN GENERAL, THE EXTENT OF DEMOLITION. REMOVE ALL ASSOCIATED APPURTENANCES NOT REQUIRED IN THE NEW WORK, ALL ABANDONED ITEMS, AND ALL ITEMS REQUIRED FOR THE INSTALLATION OF NEW WORK, TO PROVIDE FOR A COMPLETE PROJECT. ITEMS NOT SPECIFICALLY INDICATED THAT ARE QUESTIONABLE FOR REMOVAL SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR A DECISION.
THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO THE
START OF CONSTRUCTION.
THE CONTRACTOR SHALL PATCH ALL EXISTING SURFACES TO MATCH EXISTING WHERE AFFECTED BY CONSTRUCTION OPERATIONS, INCLUDING BUT NOT LIMITED TO PLUMBING, MECHANICAL AND ELECTRICAL WORK.
THE CONTRACTOR SHALL PATCH NAIL HOLES, ETC, AND REMOVE MISCELLANEOUS APPURTENANCES ON EXISTING
WALLS TO BE PAINTED OR COVERED WITH WALL COVERING.
ALL EXISTING FLOORING MATERIALS WHICH ARE TO REMAIN IN PLACE SHALL BE COMPLETELY CLEANED AND
STRIPPED OF WAX IN ORDER TO RECEIVE NEW FINISHES.
• ALL NEW WORK SHALL ALIGN WITH EXISTING WHERE THEY INTERSECT UNLESS OTHERWISE NOTED.
THE CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING SURFACES WHICH WERE PREVIOUSLY DAMAGED PRIOR TO CONSTRUCTION OPERATIONS IF VISIBLE AFTER NEW WORK IS COMPLETE, REGARDLESS IF THE ITEM WAS
SPECIFICALLY NOTED OR NOT.
THE CONTRACTOR SHALL REMOVE AND PATCH ANY AREAS UNCOVERED WHERE WOOD NAILERS OR GROUNDS ARE FOUND TO EXIST BEHIND ANY TRIM ITEMS OR EQUIPMENT REMOVED. WALLS SHALL BE MADE FLUSH WITH EXISTING
ADJACENT SURFACES AND READY TO RECEIVE NEW FINISHES.
IF ANY ASBESTOS CONTAINING MATERIAL IS ENCOUNTERED DURING THE COURSE OF CONSTRUCTION OPERATIONS WHICH IS NOT INDICATED ON THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
IMMEDIATELY.
ALL SIGNAGE WHICH OCCURS ON WALL OR ON DOORS TO BE REMOVED SHALL BE REMOVED BY THE CONTRACTOR
AND TURNED OVER TO THE OWNER.
ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS SHEET ONLY UNLESS OTHERWISE
NOTED.
THESE DEMOLITION NOTES ARE FOR ARCHITECTURAL WORK ONLY. SEE ALL OTHER DRAWINGS FOR DEMOLITION
INFORMATION PERTAINING TO OTHER DISCIPLINES.
• FOR ICRA WALL INFORMATION SEE SHEET GI004.
DOORS, FRAMES, AND HARDWARE TO BE REMOVED SHALL BE SALVAGED FOR OWNER USE. UNLESS OTHERWISE
NOTED.
• LIGHT FIXTURES TO BE REMOVED SHALL BE SALVAGED FOR OWNER USE UNLESS OTHERWISE NOTED
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
S
R
Q
20 21 22 23 24 25 26 2725A
9 10
ABV.
ABV.
ABV.
MIN
6' - 0"
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
BID DOCUMENTS
FULLY SPRINKLERED
ACTUAL & PLAN
NORTH
NTS
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AD101
DEMOLITION PLAN - LEVEL 1 - PHASE
JCHDJP
11/08/18
1/8" = 1'-0"
DEMOLITION PLAN - LEVEL 1 - PHASE 2
DEMOLITION NOTES - LEVEL 1 - PHASE 2
1 REMOVE AND RELOCATE MECHANICAL EQUIPMENT. SEE MECHANICAL DRAWINGS.
2 REMOVE FIRE DEPARTMENT CONNECTION. SEE FIRE PROTECTION DRAWINGS TO PREPARE EXISTING FDC CONNECTION FOR NEW WORK.
3 REMOVE DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY
4 REMOVE PORTION OF CONCRETE PAD.
5 REMOVE STOREFRONT SYSTEM IN ITS ENTIRETY.
6 REMOVE PAVEMENT. SEE CIVIL DRAWINGS FOR EXTENTS OF DEMOLITION.
7 REMOVE BRICK VENEER AND EXTERIOR SUBSTRATE TO FACE OF METAL STUD.
8 SEE CIVIL DRAWINGS FOR DEMOLITON AND RELOCATION OF EMERGENCY POWER DUCT BANK
9 REMOVE WALL MOUNTED EXTERIOR LIGHT FIXTURE
10 REMOVE AND DISCARD "LAMBS TOUNGE" FLANGE, SEE PLUMBING DRAWINGS TO PREPARE EXISTING OVERFLOW DRAIN FOR NEW WORK.
11 REMOVE LOUVER AND PATCH OPENING, SEE MECHANICAL DRAWINGS FOR EXTENTS OF INTERIOR DEMOLITION.
12 REMOVE EXTERIOR FACE BRICK AND METAL STUD BACKUP COMPLETE
13 REMOVE AREA / YARD DRAIN. SEE CIVIL DRAWINGS FOR DEMOLITION REQUIREMENTS.
GENERAL DEMOLITION NOTES - PHASE 2
• DEMOLITION DRAWINGS INDICATE IN GENERAL, THE EXTENT OF DEMOLITION. REMOVE ALL ASSOCIATED APPURTENANCES NOT REQUIRED IN THE NEW WORK, ALL ABANDONED ITEMS, AND ALL ITEMS REQUIRED FOR THE INSTALLATION OF NEW WORK, TO PROVIDE FOR A COMPLETE PROJECT.
ITEMS NOT SPECIFICALLY INDICATED THAT ARE QUESTIONABLE FOR REMOVAL SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR A
DECISION.
• THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION.
• THE CONTRACTOR SHALL PATCH ALL EXISTING SURFACES TO MATCH EXISTING WHERE AFFECTED BY CONSTRUCTION OPERATIONS, INCLUDING
BUT NOT LIMITED TO PLUMBING, MECHANICAL AND ELECTRICAL WORK.
• THE CONTRACTOR SHALL PATCH NAIL HOLES, ETC, AND REMOVE MISCELLANEOUS APPURTENANCES ON EXISTING WALLS TO BE PAINTED OR
COVERED WITH WALL COVERING.
• ALL EXISTING FLOORING MATERIALS WHICH ARE TO REMAIN IN PLACE SHALL BE COMPLETELY CLEANED AND STRIPPED OF WAX IN ORDER TO
RECEIVE NEW FINISHES.
• ALL NEW WORK SHALL ALIGN WITH EXISTING WHERE THEY INTERSECT UNLESS OTHERWISE NOTED.
• THE CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING SURFACES WHICH WERE PREVIOUSLY DAMAGED PRIOR TO CONSTRUCTION OPERATIONS IF VISIBLE AFTER NEW WORK IS COMPLETE, REGARDLESS IF THE ITEM WAS SPECIFICALLY NOTED OR NOT.
• THE CONTRACTOR SHALL REMOVE AND PATCH ANY AREAS UNCOVERED WHERE WOOD NAILERS OR GROUNDS ARE FOUND TO EXIST BEHIND ANY TRIM ITEMS OR EQUIPMENT REMOVED. WALLS SHALL BE MADE FLUSH WITH EXISTING ADJACENT SURFACES AND READY TO RECEIVE NEW
FINISHES.
• IF ANY ASBESTOS CONTAINING MATERIAL IS ENCOUNTERED DURING THE COURSE OF CONSTRUCTION OPERATIONS WHICH IS NOT INDICATED ON
THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY.
• ALL SIGNAGE WHICH OCCURS ON WALL OR ON DOORS TO BE REMOVED SHALL BE REMOVED BY THE CONTRACTOR AND TURNED OVER TO THE
OWNER.
• ALL FINISHES LISTED IN THE DEMOLITION SCHEDULE SHALL BE REMOVED COMPLETELY UNLESS INDICATED OTHERWISE. DEMOTION SHALL INCLUDE BACKINGS, MASTIC AND GLUES, SETTING BEDS, AND SUBSTRATE AS REQUIRED TO PREPARE THE MATERIAL FOR NEW WORK AND/OR
FINISHES.
• ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS SHEET ONLY UNLESS OTHERWISE NOTED.
• THESE DEMOLITION NOTES ARE FOR ARCHITECTURAL WORK ONLY. SEE ALL OTHER DRAWINGS FOR DEMOLITION INFORMATION PERTAINING TO
OTHER DISCIPLINES.
• FOR ICRA WALL INFORMATION SEE SHEETS GI004.
• DOORS, FRAMES, AND HARDWARE TO BE REMOVED SHALL BE SALVAGED FOR OWNER USE. UNLESS OTHERWISE NOTED.
• LIGHT FIXTURES TO BE REMOVED SHALL BE SALVAGED FOR OWNER USE UNLESS OTHERWISE NOTED
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
FC
W
V
T
R
Q
20 21 22 23 24 25
10' - 7"
12' - 5" 20' - 8"
1' - 0"
1' - 0"
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
BID DOCUMENTS
FULLY SPRINKLERED
ACTUAL & PLAN
NORTH
NTS
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AD102
DEMOLITION PLAN - ROOF - PHASE 2
JCHDJP
11/08/18
1/8" = 1'-0"
DEMOLITION PLAN - ROOF - PHASE 2
GENERAL DEMOLITION NOTES - PHASE 2
• DEMOLITION DRAWINGS INDICATE IN GENERAL, THE EXTENT OF DEMOLITION. REMOVE ALL ASSOCIATED APPURTENANCES NOT REQUIRED IN THE NEW WORK, ALL ABANDONED ITEMS, AND ALL ITEMS REQUIRED FOR THE INSTALLATION OF NEW WORK, TO PROVIDE FOR A COMPLETE PROJECT.
ITEMS NOT SPECIFICALLY INDICATED THAT ARE QUESTIONABLE FOR REMOVAL SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR A
DECISION.
• THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION.
• THE CONTRACTOR SHALL PATCH ALL EXISTING SURFACES TO MATCH EXISTING WHERE AFFECTED BY CONSTRUCTION OPERATIONS, INCLUDING
BUT NOT LIMITED TO PLUMBING, MECHANICAL AND ELECTRICAL WORK.
• THE CONTRACTOR SHALL PATCH NAIL HOLES, ETC, AND REMOVE MISCELLANEOUS APPURTENANCES ON EXISTING WALLS TO BE PAINTED OR
COVERED WITH WALL COVERING.
• ALL EXISTING FLOORING MATERIALS WHICH ARE TO REMAIN IN PLACE SHALL BE COMPLETELY CLEANED AND STRIPPED OF WAX IN ORDER TO
RECEIVE NEW FINISHES.
• ALL NEW WORK SHALL ALIGN WITH EXISTING WHERE THEY INTERSECT UNLESS OTHERWISE NOTED.
• THE CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING SURFACES WHICH WERE PREVIOUSLY DAMAGED PRIOR TO CONSTRUCTION OPERATIONS IF VISIBLE AFTER NEW WORK IS COMPLETE, REGARDLESS IF THE ITEM WAS SPECIFICALLY NOTED OR NOT.
• THE CONTRACTOR SHALL REMOVE AND PATCH ANY AREAS UNCOVERED WHERE WOOD NAILERS OR GROUNDS ARE FOUND TO EXIST BEHIND ANY TRIM ITEMS OR EQUIPMENT REMOVED. WALLS SHALL BE MADE FLUSH WITH EXISTING ADJACENT SURFACES AND READY TO RECEIVE NEW
FINISHES.
• IF ANY ASBESTOS CONTAINING MATERIAL IS ENCOUNTERED DURING THE COURSE OF CONSTRUCTION OPERATIONS WHICH IS NOT INDICATED ON
THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY.
• ALL SIGNAGE WHICH OCCURS ON WALL OR ON DOORS TO BE REMOVED SHALL BE REMOVED BY THE CONTRACTOR AND TURNED OVER TO THE
OWNER.
• ALL FINISHES LISTED IN THE DEMOLITION SCHEDULE SHALL BE REMOVED COMPLETELY UNLESS INDICATED OTHERWISE. DEMOTION SHALL INCLUDE BACKINGS, MASTIC AND GLUES, SETTING BEDS, AND SUBSTRATE AS REQUIRED TO PREPARE THE MATERIAL FOR NEW WORK AND/OR
FINISHES.
• ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS SHEET ONLY UNLESS OTHERWISE NOTED.
• THESE DEMOLITION NOTES ARE FOR ARCHITECTURAL WORK ONLY. SEE ALL OTHER DRAWINGS FOR DEMOLITION INFORMATION PERTAINING TO
OTHER DISCIPLINES.
• FOR ICRA WALL INFORMATION SEE SHEETS GI004.
• DOORS, FRAMES, AND HARDWARE TO BE REMOVED SHALL BE SALVAGED FOR OWNER USE. UNLESS OTHERWISE NOTED.
• LIGHT FIXTURES TO BE REMOVED SHALL BE SALVAGED FOR OWNER USE UNLESS OTHERWISE NOTED
DEMOLITION NOTES - ROOF - PHASE 2
1 REMOVE AND DISCARD GRAVEL STOP AND FASCIA. SEE SHEETS AE112 AND AE113 FOR EXTENTS, PROTECT EDGES OF ROOF AND PREPARE IT
FOR NEW CONSTRUCTION.
2 REMOVE AND DISCARD ROOF SYSTEM AND INSULATION TO ROOF DECK. PROTECT REMAINING ROOF AND DECK UNTIL NEW WORK IS COMPLETE.
3 REMOVE AND DISCARD LOUVER. COORDINATE PHASING AND TEMPORARY EXHAUST WITH MECHANICAL DRAWINGS.
4 REMOVE WALL TO ACCEPT NEW CORRIDOR. SEE AE112 FOR EXTENTS.
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
UP
AE402
AE402
AE402
T
R
Q
20 23
AE500
AE4001
AE500
AE500
R.1
21.1
21.1 22.1
22.1
Q.2 Q.2
20.1
20.1
R.2
S.2
23.1 24.1
24.1
25.1
25.1
27.1
27.1
P.1
RR
SS
25.3
25.4
25.4
21.2
S.1
26.1
26.1
AE400
Q.1 Q.1
25.2
5' - 0" 24' - 10 1/2" 27' - 0" 1' - 8" 20' - 10" 20' - 10" 21' - 8"
21' - 8"
21' - 4"
17' - 8"
1Z-232
1Z-229
1Z-228
1Z-227
1Z-225
1Z-230
1Z-237
1Z-2141Z-213
1Z-212
1Z-209
1Z-208
1Z-224
1Z-223
1Z-222
1Z-220
1Z-217
1Z-226
1Z-231
Z
-2
1Z-E1
1Z-206
1Z-207
1Z-S1
1Z-211
1Z-202
1Z-200
1Z-203
1Z-204
1Z-205
10' - 10 1/4"
1Z-C
1Z-C2 Z
-C
1Z-201
1Z-210
E100
AE510
1Z-216
17' - 10 1/2" 8' - 1 1/2" 9' - 3 1/2" 15' - 6" 36' - 0 9/16"
/1
6"
5'
3/
8"
/4
6' - 1 1/4"
33' - 8 3/4"
10' - 0 5/8"
M .O
.4'
0"
6'
8" M
.O .4'
0"
6'
8" M .O
.4'
0"
1' - 8" 5' - 4"
M .O
4' - 0"
6' - 8"
M .O
4' - 0"
6' - 8"
M .O
4' - 0"
6' - 8"
M .O
4' - 0"
6' - 8"
M .O
4' - 0"
/8
3' - 8"
M .O
4' - 0" 3' - 2 1/4"
3'
8" M .O
.3'
4"
± 30' - 8" 65' - 0"
F
/2
/8
/4
/2
AE402
AE502
CLEAR
6' - 0"
AE402
/2
/2
/2
D
D
A
E
A
A
A
A
A
A
A
A
A
A
/4
/1
/1
AE401 1
AE401
TEMPORARY CONSTRUCTION BARRIER,
SEE ICRA ASSESSMENT PLAN
TEMPORARY CONSTRUCTION
BARRIER, SEE ICRA
ASSESSMENT PLAN
.0
135.00°
M .O
/2
/2
.0
± 2' - 11"
135.00°
1Z-219
1Z-235
1Z-236
Z
-C
1Z-221
1Z -C
1'
8" M
.O .3'
4"
3'
8"
A
M .O
.4'
0"
9'
2"
1Z-234
1Z-218
NOTE: SEE AE121 FOR OPENING
DIMENSIONS AT COURTYARD
A E
A E
R.3
MATCHLINE
WORK
POINT
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
BID DOCUMENTS
FULLY SPRINKLERED
ACTUAL & PLAN
NORTH
NTS
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AE111
NEW WORK PLAN - LEVEL 1 - PHASE 2
JCHDJP
11/08/18
1/8" = 1'-0"
OVERALL NEW WORK PLAN - LEVEL 1 - PHASE 2
ROOM LEGEND - LEVEL 1 - PHASE 2
NUMBER NAME
1Z-200 WAITING
1Z-201 RECEPTION
1Z-202 BLOOD DRAW / VITALS
1Z-203 TOILET
1Z-204 TOILET
1Z-205 STORAGE
1Z-206 CLEAN LINEN
1Z-207 SOILED LINEN
1Z-208 CHEMOTHERAPY TREATMENT ROOM
1Z-209 NURSE STATION
1Z-210 PHARMACIST
1Z-211 ANTE
1Z-212 HD BUFFER
1Z-213 TOILET
1Z-214 TOILET
1Z-215 ELEV. EQUIP.
1Z-216 TELE. / DATA
1Z-217 ELEC.
1Z-218 MECH.
1Z-219 CONFERENCE / CONSULT
1Z-220 EXAM ROOM 8
1Z-221 TOILET
1Z-222 EXAM ROOM 7
1Z-223 EXAM ROOM 6
1Z-224 EXAM ROOM 5
1Z-225 EXAM / PROCEDURE
1Z-226 EXAM ROOM 9
1Z-227 EXAM ROOM 4
1Z-228 EXAM ROOM 3
1Z-229 EXAM ROOM 2
1Z-230 TEAM ROOM
1Z-231 TOILET
1Z-232 EXAM ROOM 1
1Z-234 STORAGE
1Z-235 MEDICINE
1Z-236 LOUNGE
1Z-237 KITCHEN
1Z-C1 CORRIDOR
1Z-C2 CORRIDOR
1Z-C3 CORRIDOR
1Z-C4 CORRIDOR
1Z-E1 ELEV.
1Z-S1 STAIR 1
GENERAL NEW WORK NOTES - PHASE 2
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE
FEDERAL, STATE AND LOCAL CODES AND ORDINANCES.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO
THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT
TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A RESOLUTION.
EACH SUB CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS
AND EVALUATE THE SCOPE OF WORK REQUIRED BY THEIR RESPECTIVE
TRADE AND ANY CONFLICTS WITH OTHER TRADES. ANY CONFLICTS WILL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A
RESOLUTION.
PROVIDE SHALL MEAN TO SUPPLY, TO FURNISH AND TO INSTALL COMPLETE
WITH ALL ACCESSORIES, PARTS AND/OR SERVICES TO BE READY FOR ITS
INTENDED USE.
WHERE WORK ABUTTS OR ADJOINS EXISTING SURFACES, WHICH WILL
REMAIN EXPOSED, ALIGN NEW WORK FLUSH WITH EXISTING ADJACENT
SURFACES.
CONTRACTOR SHALL COORDINATE ALL REQUIRED CONDUIT, PIPING AND
CHASES FOR OWNER FURNISHED OWNER INSTALLED EQUIPMENT WITH THE
OWNER.
CONTRACTOR SHALL PROVIDE BARRIERS TO PREVENT ENTRY TO THE
CONSTRUCTION AREA. BARRIERS SHALL NOT INTERFERE WITH THE OWNERS
USE OF THE SITE OR SAFE MEANS OF EGRESS.
THE CONTRACTOR SHALL PROVIDE NEGATIVE PRESSURE IN THE AREA OF
RENOVATION TO PREVENT THE SPREAD OF DUST TO OCCUPIED AREAS OF
THE BUILDING.
ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS
SHEET ONLY UNLESS OTHERWISE NOTED.
• ALL DOORS TO BE MOUNTED 6" FROM FACE OF FINISH UON.
ALL MODIFICATIONS TO THE EXISTING ROOF SHALL BE MADE IN
ACCORDANCE WITH VAMC'S EXISTING ROOF WARRANTY. COORDINATE ALL
MODIFICATIONS TO THE ROOF WITH THE COR.
ALL SYMBOLS WHOSE TYPE IS NOT INDICATED ON THE SHEET CAN BE
REFERENCED FROM SHEET AG001
• SEE SHEET AG001 FOR WALL TYPE SCHEDULE.
SEE OVERALL NEW WORK PLANS FOR EXTERIOR AND OVERALL INTERIOR
DIMENSIONS
SEE ENLARGED PLANS FOR WALL TYPE LOCATIONS AND INTERIOR
DIMENSIONING
• SEE EQUIPMENT PLANS FOR INTERIOR ELEVATION LOCATIONS
CONTRACTOR SHALL COORDINATE WITH WORK BEING PERFORMED UNDER
SEPARATE CONTRACT BY VA COR.
SEE LIFE SAFETY PLAN FOR FIRE BARRIER AND SMOKE PARTITION
LOCATIONS.
SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIGHTING AND
DIFFUSER TYPES.
ALL ABUTTING DISSIMILAR MATERIALS ARE TO BE SEALED. COLOR TO MATCH
ADJACENT MATERIALS.
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
DN
RR
AE500
AE4001
AE500
AE500
2Z-248
2Z-250
2Z-247
2Z-241 2Z-240
2Z-258
2Z-2562Z-255
2Z-257
2Z-259
2Z-239
2Z-S1
2Z-261
R.1 R.1
22.1
22.1
Q.2Q.2
S.2
23.1
23.1
24.1
24.1
25.1
25.1
SS
25.3
2Z-242
2Z-243
2Z-249
2Z-251
2Z-C2
2Z-252
Z
-2
AE401 1
AE400
2Z-244
2Z-E1
Q.1
25.2
AE502
2Z-245
2Z-246
24' - 0" 56' - 7"
1' - 8"
20' - 10" 20' - 10" 21' - 8" 22' - 10 1/2"
9' - 4"
M.O.
4' - 0" 3' - 8"
M.O.
4' - 0" 3' - 8"
M.O.
4' - 0" 15' - 0" 15' - 0"
M.O.
4' - 0" 4' - 0"
1' - 8" 20' - 10" 20' - 10" 21' - 8"
1' - 8"
/8
/8
J
AE900
2Z-C3
2Z-C1
AE402
AE502
2Z-253
2Z-260 A
A
A
A
A
AAAA
A
A
A
A
A
B
A
A
AE40211
M .O
M .O
M .O
M .O
M .O
M .O
A
M .O
M .O
M .O
M .O
M .O
/8
M.O.
4' - 0" 3' - 8" 4' - 0" 5' - 7"
AE403
AE4029
AE123
TYP.
AE310
AE310
SIM
C2B
2Z-238 2Z-262
1' - 6"
66' - 8" 22' - 4"
R.3
AE401
J
A R
E A
B
A R
E A
A
W
25 2625A
SS25.3
S.1
25.2
8' - 5" 12' - 1"
Z
-C
AE502
AE502
22' - 4"
M .O
M .O
M .O
M .O
M .O
M .O
M .O
/4
C1A
M3_2
M349_2S
AE502
A
A
C
C
C
C
AE403
AE403
AE502
C
C
M.O.
4' - 0" 3' - 8" 4' - 0" 5' - 7"
12' - 1"
6' - 1"
A L
IG
N
CLEAR
5' - 10"
2Z-C2
C1C
M3_2
/1
R A
M P
0' - 0"
0' - 0"
-0' - 4"
-0' - 4"
-0' - 4"
C2B
C1B
2Z-238 2Z-262
R.3
A R
E A
B
A R
E A
A
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
BID DOCUMENTS
FULLY SPRINKLERED
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AE112
NEW WORK PLAN - LEVEL 2 - PHASE 2
JCHDJP
11/08/18
1/8" = 1'-0"
NEW WORK - LEVEL 2 - AREA A - PHASE 2
1/8" = 1'-0"
NEW WORK - LEVEL 2 - AREA B - PHASE 2
ROOM LEGEND - LEVEL 2 - PHASE 2
NUMBER NAME
ROOM LEGEND - LEVEL 2 - PHASE 2
NUMBER NAME
2Z-253 N.P. OFFICE
2Z-254 CORRIDOR
2Z-255 F.T. ATTEND
2Z-256 F.T. ATTEND
2Z-257 F.T. ATTEND
2Z-258 F.T. ATTEND
2Z-259 F.T. ATTEND
2Z-260 MICROSCOPE
2Z-261 RECEPTION / ADMIN.
2Z-262 STORAGE
2Z-C1 CORRIDOR
2Z-C2 CORRIDOR
2Z-C3 CORRIDOR
2Z-E1 ELEV.
2Z-S1 STAIR 1
ROOM LEGEND - LEVEL 2 - PHASE 2
NUMBER NAME
2Z-238 TOILET
2Z-239 TOILET
2Z-240 TELE. / DATA
2Z-241 ELEC.
2Z-242 TELE. MED / SMALL CONF.
2Z-243 FLEX CONF. SPACE
2Z-244 COPY ROOM
2Z-245 F.T. ATTEND.
2Z-246 F.T. ATTEND.
2Z-247 CHIEF RADIATION ONCOLOGY
2Z-248 F.T. ATTEND.
2Z-249 N.P. OFFICE
2Z-250 PHYSICS W.S.
2Z-251 CHIEF PHYSICS
2Z-252 CORRIDOR
GENERAL NEW WORK NOTES - PHASE 2
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE
FEDERAL, STATE AND LOCAL CODES AND ORDINANCES.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO
THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT
TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A RESOLUTION.
EACH SUB CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS
AND EVALUATE THE SCOPE OF WORK REQUIRED BY THEIR RESPECTIVE
TRADE AND ANY CONFLICTS WITH OTHER TRADES. ANY CONFLICTS WILL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A
RESOLUTION.
PROVIDE SHALL MEAN TO SUPPLY, TO FURNISH AND TO INSTALL COMPLETE
WITH ALL ACCESSORIES, PARTS AND/OR SERVICES TO BE READY FOR ITS
INTENDED USE.
WHERE WORK ABUTTS OR ADJOINS EXISTING SURFACES, WHICH WILL
REMAIN EXPOSED, ALIGN NEW WORK FLUSH WITH EXISTING ADJACENT
SURFACES.
CONTRACTOR SHALL COORDINATE ALL REQUIRED CONDUIT, PIPING AND
CHASES FOR OWNER FURNISHED OWNER INSTALLED EQUIPMENT WITH THE
OWNER.
CONTRACTOR SHALL PROVIDE BARRIERS TO PREVENT ENTRY TO THE
CONSTRUCTION AREA. BARRIERS SHALL NOT INTERFERE WITH THE OWNERS
USE OF THE SITE OR SAFE MEANS OF EGRESS.
THE CONTRACTOR SHALL PROVIDE NEGATIVE PRESSURE IN THE AREA OF
RENOVATION TO PREVENT THE SPREAD OF DUST TO OCCUPIED AREAS OF
THE BUILDING.
ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS
SHEET ONLY UNLESS OTHERWISE NOTED.
• ALL DOORS TO BE MOUNTED 6" FROM FACE OF FINISH UON.
ALL MODIFICATIONS TO THE EXISTING ROOF SHALL BE MADE IN
ACCORDANCE WITH VAMC'S EXISTING ROOF WARRANTY. COORDINATE ALL
MODIFICATIONS TO THE ROOF WITH THE COR.
ALL SYMBOLS WHOSE TYPE IS NOT INDICATED ON THE SHEET CAN BE
REFERENCED FROM SHEET AG001
• SEE SHEET AG001 FOR WALL TYPE SCHEDULE.
SEE OVERALL NEW WORK PLANS FOR EXTERIOR AND OVERALL INTERIOR
DIMENSIONS
SEE ENLARGED PLANS FOR WALL TYPE LOCATIONS AND INTERIOR
DIMENSIONING
• SEE EQUIPMENT PLANS FOR INTERIOR ELEVATION LOCATIONS
CONTRACTOR SHALL COORDINATE WITH WORK BEING PERFORMED UNDER
SEPARATE CONTRACT BY VA COR.
SEE LIFE SAFETY PLAN FOR FIRE BARRIER AND SMOKE PARTITION
LOCATIONS.
SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIGHTING AND
DIFFUSER TYPES.
ALL ABUTTING DISSIMILAR MATERIALS ARE TO BE SEALED. COLOR TO MATCH
ADJACENT MATERIALS.
NEW WORK NOTES - LEVEL 2 - PHASE 2
1 ROOF AND OVERFLOW DRAIN, SEE PLUMBING DRAWINGS.
2 PREFINISHED METAL COPING. INSTALL PER MANUFACTURER SPECIFICATIONS.
3 ELECTRIC WATER COOLER TO MATCH BUILDING STANDARD. SEE PLUMBING DRAWINGS.
4 FIRE EXTINGUISHER CABINET. SEE SPECS.
DENOTES TEMPORARY FIRE RATED DOOR AND ICRA HARDWALL BARRIER - 1 HR FIRE RATED
CONSTRUCTION BARRIER. WALL TO BE: 5/8" TYPE X GWB BOTH SIDES OF 3 5/8" MTL STUDS AT 16" OC, EXTEND TO DECK / SLAB ABOVE WITH FIRE RATED SEALANT AT TOP AND BOTTOM CONNECTIONS ON BOTH
SIDES
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
DN
TT
S
R
Q
20 21
22 23
AE500
AE500
AE500
R.1
21.1
22.1
22.1
Q.2
20.1
R.2
S.2
23.1
23.1
24.1
24.1
25.1
25.1
27.1
27.1
P.1
RR
SS
25.3
25.4
21.2
26.1
26.1
26.2
Q.1
25.2
AE502
S1.1
AE900
AE502
OPEN TO
BELOW
9' - 9 1/4"
1Z-S1
C8_1
M649_1
M649_1
INTERSTITIAL
SPACE
SW_1
SW_1
AE310
SW_1
C L E
A R
/4
C L E
A R
C L E
A R
5' - 7"
CLEAR
3' - 6"
CLEAR
14' - 3 5/8"
/4
SW_1 SW_1
4' - 11 1/2"
CLEAR
10"
5' - 2 3/4"
CLEAR
10"
/4
C
L E
A R
/4
/4
C L E
A R
26' - 8 3/4"
R.3
7 7
AE602
R
AE500
AE500
R.1
22.1
22.1
Q.2
S.2
23.1
23.1
24.1
24.1
25.1
25.1
S.1
AE502
S1.4
AE900
C8_1C8_1
9' - 9 1/4"
2Z-S1
INTERSTITIAL
SPACE
AE511
SHAFT BELOW
4' - 11 1/2"
10"
5' - 2 3/4"
10"
R.3
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
BID DOCUMENTS
FULLY SPRINKLERED
ACTUAL & PLAN
NORTH
NTS
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AE113
NEW WORK PLAN - INTERSTITIALS -
PHASE 2
JCHDJP
11/08/18
1/8" = 1'-0"
NEW WORK PLAN - LEVEL 1 INTERSTITIAL - PHASE 2
NEW WORK NOTES - INTERSTITIALS - PHASE 2
1 EXISTING EXTERIOR FINISH TO REMAIN EXPOSED WHERE INTERSTITAL SPACE MEETS EXISTING BUILDING, TYPICAL.
2 FIRE EXTINGUISHER CABINET. SEE SPECS
3 NEW STEEL SHIP LADDER FOR ROOF ACCESS.
4 PROVIDE FIRE SAFING AND SEAL JOINTS TO MAINTAIN FIRE RATING.
5 PROVIDE SEALANT AND BACKER ROD CONTINUOUS AT ALL EXPANSION JOINTS, TYPICAL.
6 PROVIDE FLOOR TO WALL INTERIOR EXPANSION JOINT COVER.
7 PROVIDE WALL TO WALL INTERIOR EXPANSION JOINT COVER.
8 MECHANICAL PIPING, SEE MECHANICAL DRAWINGS.
1/8" = 1'-0"
NEW WORK - LEVEL 2 INTERSTITIAL - PHASE 2
GENERAL NEW WORK NOTES - PHASE 2.
• ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A RESOLUTION.
EACH SUB CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS AND EVALUATE THE SCOPE OF WORK REQUIRED BY THEIR RESPECTIVE TRADE AND ANY CONFLICTS WITH OTHER TRADES. ANY CONFLICTS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR A RESOLUTION.
PROVIDE SHALL MEAN TO SUPPLY, TO FURNISH AND TO INSTALL COMPLETE WITH ALL ACCESSORIES, PARTS AND/OR SERVICES TO BE READY
FOR ITS INTENDED USE.
WHERE WORK ABUTTS OR ADJOINS EXISTING SURFACES, WHICH WILL REMAIN EXPOSED, ALIGN NEW WORK FLUSH WITH EXISTING ADJACENT
SURFACES.
CONTRACTOR SHALL COORDINATE ALL REQUIRED CONDUIT, PIPING AND CHASES FOR OWNER FURNISHED OWNER INSTALLED EQUIPMENT WITH
THE OWNER.
CONTRACTOR SHALL PROVIDE BARRIERS TO PREVENT ENTRY TO THE CONSTRUCTION AREA. BARRIERS SHALL NOT INTERFERE WITH THE
OWNERS USE OF THE SITE OR SAFE MEANS OF EGRESS.
THE CONTRACTOR SHALL PROVIDE NEGATIVE PRESSURE IN THE AREA OF RENOVATION TO PREVENT THE SPREAD OF DUST TO OCCUPIED
AREAS OF THE BUILDING.
• ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS SHEET ONLY UNLESS OTHERWISE NOTED.
• ALL DOORS TO BE MOUNTED 6" FROM FACE OF FINISH UON.
ALL MODIFICATIONS TO THE EXISTING ROOF SHALL BE MADE IN ACCORDANCE WITH VAMC'S EXISTING ROOF WARRANTY. COORDINATE ALL
MODIFICATIONS TO THE ROOF WITH THE COR.
• ALL SYMBOLS WHOSE TYPE IS NOT INDICATED ON THE SHEET CAN BE REFERENCED FROM SHEET AG001
• SEE SHEET AG001 FOR WALL TYPE SCHEDULE.
• SEE OVERALL NEW WORK PLANS FOR EXTERIOR AND OVERALL INTERIOR DIMENSIONS
• SEE ENLARGED PLANS FOR WALL TYPE LOCATIONS AND INTERIOR DIMENSIONING
• SEE EQUIPMENT PLANS FOR INTERIOR ELEVATION LOCATIONS
• CONTRACTOR SHALL COORDINATE WITH WORK BEING PERFORMED UNDER SEPARATE CONTRACT BY VA COR.
• SEE LIFE SAFETY PLAN FOR FIRE BARRIER AND SMOKE PARTITION LOCATIONS.
• SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIGHTING AND DIFFUSER TYPES.
• ALL ABUTTING DISSIMILAR MATERIALS ARE TO BE SEALED. COLOR TO MATCH ADJACENT MATERIALS.
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
R
Q
AE500
AE500
R.1
21.1 22.120.1
R.2
S.2
23.1 24.1 25.121.2
S.1
AE402 5
AE502
/2
1Z-214
1Z-213
1Z-209
1Z-208
1Z-217
1Z-215
1Z-E1
1Z-206
1Z-207
1Z-S1
1Z-211
1Z-202
1Z-200
1Z-203
1Z-204
1Z-205
1Z-C2
1Z-C1
1Z-201
1Z-210
C1
1Z-216
/8
/4
/2
/2
/2 "13
/8
/8
22' - 10 1/2" 11' - 6"
/8
/8
/8
± 8' - 0 9/16"
/4
/4
/8
AE122
AE900
AE900
208B
202 203
208A
213 214
S1B
M3
M3
M3
M3
M3
M3
M3
M349
M349
M3
M349
M349
M349M349
M349
M349
M3
M3_1
SW_1
M1B
M3_1
M3_1
M3_1
M3_1
M3_1
M3_1
M3
M3_1
M3_1
M349
M3
M3
M3
M640 M3
M349
M640
M6
M340B
M349
M349
M349
M349
M349
M3
M349
M3
M3
200A
208C
M349
M6
2' - 8" 8' - 6 1/8" 3' - 3 1/2"
/8
/8
/8
3' - 10 1/4" 17' - 6 7/8"
8' - 0" MIN. CLEAR
8' - 1 1/2" 9' - 3 1/2" 15' - 6" 25' - 10"
/8
M1B
A L
IG
N
/2
/8
3' - 8 5/8"
2' - 0 7/8"
3' - 3 1/2"
/8
5' - 5 1/4"5' - 5 1/4"
EQ EQ
11' - 2 7/8"
9' - 0" TYP
E Q
E Q
6 1/8"
10' - 2 3/4"
S
IN
K
M3
M349
M349
1'
3/
4" M
.O .4'
0"
2'
8"
M .O
.10
4'
0"
M .O
.10
2'
8" M
.O .3'
4"
/4
COURTYARD
SEE CIVIL DRAWINGS
13' - 9 1/8" 8' - 1" 13' - 2 1/2"
/2
/8
11' - 5 5/8" 11' - 1"
1Z-237
1Z-212
1Z-C4
/8
1Z-211A
3' - 6 3/8"
211A
/4
M3
S1A
AE122
AE602
/8
7' - 9 3/8" 7' - 9 7/8" 9' - 6 1/16" 11' - 4 5/8" 11' - 0 1/2"
/8
3' - 6"
6"
4" 4"
M1B
M1B
M1B
M349 M349
3' - 0"
/4
/4
/8
9' - 1 5/8" 6' - 2 5/16" 3' - 10 3/8" 3' - 9 5/8" 13' - 10 1/4"
1' - 7 3/4"
3' - 10"
4' - 0 1/8"
R.3
SW_1
M3_1C
M1BM1B
M340B
M3B
TYP ENTIRE LEGNTH
OF EXISTING WALL
2 1
9 9
M3
M640
/2
M340B
M340B
M340B
O F
D O
O R
CONTRACTOR'S NOTE
FOR INTERIOR ELEVATIONS AND EQUIPMENT
PLANS SEE AE700, AE701, AE702, AE703.
A Se rv ic e D i s a b le d Ve t e r an Owned
S m a l l B u s iness
SDVOSB
CVE
www.pfa-architect.com - Project No: ####
ARCHITECTURE, PLANNING,
INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510 Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0004
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
BID DOCUMENTS
FULLY SPRINKLERED
ACTUAL & PLAN
NORTH
NTS
CONSTRUCT CANCER
CENTER
VAMC RICHMOND, VA
652-318
11-08-2018
BLDG. 500
Department of
Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL
ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
AE121
ENLARGED PLAN - LEVEL 1A - PHASE 2
JCHDJP
11/08/18
1/4" = 1'-0"
ENLARGED PLAN - LEVEL 1 - AREA A - PHASE 2
GENERAL NEW WORK NOTES - PHASE 2
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE
FEDERAL, STATE AND LOCAL CODES AND ORDINANCES.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO
THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT
TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A RESOLUTION.
EACH SUB CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS
AND EVALUATE THE SCOPE OF WORK REQUIRED BY THEIR RESPECTIVE
TRADE AND ANY CONFLICTS WITH OTHER TRADES. ANY CONFLICTS WILL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A
RESOLUTION.
PROVIDE SHALL MEAN TO SUPPLY, TO FURNISH AND TO INSTALL COMPLETE
WITH ALL ACCESSORIES, PARTS AND/OR SERVICES TO BE READY FOR ITS
INTENDED USE.
WHERE WORK ABUTTS OR ADJOINS EXISTING SURFACES, WHICH WILL
REMAIN EXPOSED, ALIGN NEW WORK FLUSH WITH EXISTING ADJACENT
SURFACES.
CONTRACTOR SHALL COORDINATE ALL REQUIRED CONDUIT, PIPING AND
CHASES FOR OWNER FURNISHED OWNER INSTALLED EQUIPMENT WITH THE
OWNER.
CONTRACTOR SHALL PROVIDE BARRIERS TO PREVENT ENTRY TO THE
CONSTRUCTION AREA. BARRIERS SHALL NOT INTERFERE WITH THE OWNERS
USE OF THE SITE OR SAFE MEANS OF EGRESS.
THE CONTRACTOR SHALL PROVIDE NEGATIVE PRESSURE IN THE AREA OF
RENOVATION TO PREVENT THE SPREAD OF DUST TO OCCUPIED AREAS OF
THE BUILDING.
ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS
SHEET ONLY UNLESS OTHERWISE NOTED.
• ALL DOORS TO BE MOUNTED 6" FROM FACE OF FINISH UON.
ALL MODIFICATIONS TO THE EXISTING ROOF SHALL BE MADE IN
ACCORDANCE WITH VAMC'S EXISTING ROOF WARRANTY. COORDINATE ALL
MODIFICATIONS TO THE ROOF WITH THE COR.
ALL SYMBOLS WHOSE TYPE IS NOT INDICATED ON THE SHEET CAN BE
REFERENCED FROM SHEET AG001
• SEE SHEET AG001 FOR WALL TYPE SCHEDULE.
SEE OVERALL NEW WORK PLANS FOR EXTERIOR AND OVERALL INTERIOR
DIMENSIONS
SEE ENLARGED PLANS FOR WALL TYPE LOCATIONS AND INTERIOR
DIMENSIONING
• SEE EQUIPMENT PLANS FOR INTERIOR ELEVATION LOCATIONS
CONTRACTOR SHALL COORDINATE WITH WORK BEING PERFORMED UNDER
SEPARATE CONTRACT BY VA COR.
SEE LIFE SAFETY PLAN FOR FIRE BARRIER AND SMOKE PARTITION
LOCATIONS.
SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIGHTING AND
DIFFUSER TYPES.
ALL ABUTTING DISSIMILAR MATERIALS ARE TO BE SEALED. COLOR TO MATCH
ADJACENT MATERIALS.
NEW WORK NOTES - LEVEL 1A - PHASE 2
PROVIDE WALL TO WALL INTERIOR EXPANSION JOINT COVER TYPICAL. SEE
1/AE602
PROVIDE FLOOR…
This is the start of the file's text. The full file is on GovTribe.