36C24619B0040-0003004.pdf
PDF 70 KB Posted
- Attached to
- 652-318 Construct Cancer Center (VA-19-00013696)
- Solicitation number
- 36C24619B0040
About this file
This document contains a federal contract opportunity solicitation for construction services and related quality control reporting requirements. The Department of Veterans Affairs is seeking a Service Disabled Veteran Owned Small Business to construct a two story, 15,000 square foot cancer center addition at the H.H. McGuire VA Medical Center in Richmond, Virginia for an estimated cost between $5-10 million. The work must be completed within 630 calendar days of receiving the notice to proceed and shall be performed in accordance with construction drawings and specifications prepared by Miller-Remick, LLC. The solicitation number is 36C24619B0040 and will be issued on or about August 15, 2019. A pre-proposal site visit will also be scheduled. Questions must be emailed to the contracting officer by the deadline stated in the solicitation. The opportunity is fully set aside for SDVOSBs and non-SDVOSB offers will not be considered. The contractor will be required to submit daily quality control reports on Form SAM 696.
36C24619B0040 0003 014500.10 (01-2018) Attach A - QCR Example Form.pdf
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACTOR'S QUALITY CONTROL REPORT (QCR)
D A T E: R E P O R T N O.:
C O N T R A C T N U M B E R A N D N A M E O F C O N T R A C T O R: D E S C R I P T I ON A N D L O C A T I O N O F T H E W O R K:
W E A T H E R C L A S S I F I C A T I O N :
CLASS A
CLASS B
CLASS C
CLASS D
CLASS E
OTHER
C L A S S I F I C A T I O N :
C L A S S
T E M P E R A T U R E :
M A X M I N
P R E C I P I T A T I O N :
I N C H E S
(ER 1180-1-6)
No interruptions of any kind from weather conditions occurring on this or previous shifts.
Weather occurred during this shift that caused a complete stoppage of all work.
Weather occurred during this shift that caused a partial stoppage of work.
Weather overhead excellent or suitable during shift. Work completely stopped due to results of previous adverse weather.
Weather overhead excellent or suitable during shift but work partially stopped due to previous adverse manner.
Explain.
CONTRACTOR/SUBCONTRACTORS AND AREA OF RESPONSIBILITY FOR WORK PERFORMED TODAY: (Attach list of items of equipment either idle or working as appropriate.)
1. WORK PERFORMED TODAY: (Indicate location and description of work performed. Refer to work performed by prime and/or subcontractors by letter in Table above.)
2. TYPE AND RESULTS OF INSPECTION: (Indicate whether: P - Preparatory, I - Initial, or F - Follow-up and include satisfactory work completed or deficiencies with action to be taken.)
3. TESTS REQUIRED BY PLANS AND/OR SPECIFICATIONS PERFORMED AND RESULTS OF TESTS:
SAM 696FORM
1 SEP 79 Previous Edition May Be Used Until Exhausted
PURPOSE: Contractors Daily QC Report. Revision necessitated by EIG recommendation
MONTHLY USAGE: 1,500
PRESCRIBING DIRECTIVE: ER 1180-1-6
FUNCTIONAL CODE: 1180 Series - Engineer Contracts a.
b.
c.
d.
e.
f.
g.
vacobofint Rectangle vacobofint Rectangle vacobofint Sticky Note Accepted set by vacobofint
4. VERBAL INSTRUCTIONS RECEIVED: (List any instructions given by Government personnel on construction deficiencies.
retesting required, etc., with action to be taken.)
5. REMARKS: (Cover any conflicts in plans, specifications or instructions: acceptability of incoming materials: offsite surveillance activities; progress of work, delays, causes and extent thereof; days of no work with reasons for same.)
6. SAFETY: (Include any infractions of approved safety plan, safety manual or instructions from Government personnel.
Specify corrective action taken.)
CONTRACTOR'S CERTIFICATION: I certify that the above report is complete and correct and that all material and equipment used, work performed and tests conducted during this reporting period were in strict compliance with the contract plans and specifications except as noted above.
INSPECTOR
CONTRACTOR'S APPROVED AUTHORIZED REPRESENTATIVE
| 17-R-0002 Amendment 0003 Volume I (Phase II) |
| Amendment 0003 Narrative |
| Phase Two - Volume 1 of 3 |
| Table of Contents |
| Bidding Requirements |
| DIVISION 1 - GENERAL REQUIREMENTS |
| 01 00 00 |
| LIST OF PERMITS REQUIRED |
| PROJECT SIGNS |
| WAGE RATES |
| 01 00 01.02 DoVA CEMP |
| 01 10 10 DESIGN REQUIREMENTS |
| 1 DESCRIPTION OF FACILTIY AND SCOPE |
| 2 DESIGN REQUIREMENTS |
| 3 GENERAL REQS for PERMITTING, LIFE SAFETY and SECURITY REQUIREMENTS |
| 4 SITE |
| 5 ARCHITECTURE |
| 6 CONVEYING SYSTEMS |
| 7 INTERIOR DESIGN, SIGNAGE & F, F & E |
| 8 STRUCTURAL DESIGN |
| 9 HVAC |
| 10 (not used) |
| 11 PLUMBING |
| 12 (not used) |
| 13 FIRE PROTECTION & LIFE SAFETY |
| 14 (not used) |
| 15 ELECTRICAL |
| 16 SECURITY SYSTEMS |
| 17 COMMUNICATIONS |
| 18 CORROSION AND CATHODIC PROTECTION |
| 19 ENVIRONMENTS - HAZARDOUS MATERIALS |
| 20 SUSTAINABLE DESIGN |
| 21COMMSSIONING |
| 01 10 12 DESIGN AFTER AWARD |
| 01 14 00 WORK RESTRICTIONS |
| 01 32 00.00 10 PROJECT SCHEDULE |
| 01 33 00 SUBMITTAL PROCEDURES |
| Submittal Register |
| Standard Form 4025 |
| 01 33 29 SUSTAINABILITY REPORTING |
| 01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS |
| 01 42 00 SOURCES FOR REFERENCE PUBLICATIONS |
| 01 45 00.00.10 QUALITY CONTROL |
| QCR-SAM FORM 696 |
| 01 45 00.15.01 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM) |
| 01 45 35 SPECIAL INSPECTIONS |
| 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS |
| 01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVINROMENTAL CONTROLS |
| 01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT |
| 01 78 23 OPERATION AND MAINTENANCE DATA |
| 17-R-0002 Amendment 0003 Volume II (Phase II) |
| Phase Two - Volume 2 of 3 |
| Table of Contents |
| APPENDIX A - WORK RESTRICITIONS DOCUMENTS |
| APPENDIX B - PRESCIPTIVE SPECIFICATIONS |
| 01 81 13 SUSTAINABLE CONSTRUCTION REQUIREMENTS |
| 01 81 16 HEALTHCARE SUSTAINABLE DESIGN REQUIREMENTS |
| 01 81 21 IAQ MANAGEMENT DURING CONSTRUCTION |
| 01 81 22 IAQ PROTECTION BEFORE OCCUPANCY |
| 01 91 00 GENERAL COMMISSIONING REQUREMENTS |
| 07 08 00 FACILITY EXTERIOR CLOSURE COMMISSIONING |
| 14 21 00 ELECTRIC TRACTION ELEVATOR |
| 14 24 00 HYDRAULIC ELEVATOR |
| 14 92 19 SIX (6") PNEUMATIC TUBES |
| 21 09 00 COMMSSIONING OF FIRE SUPPRESION SYSTEM |
| 22 08 00 COMMSSIONING OF PLUMBING SYSTEM |
| 23 08 00 COMMSSIONING OF HVAC SYSTEM |
| 26 08 00 COMMSSIONING OF ELECTRICAL SYSTEM |
| 26 09 13 ELECTRICAL POWER MONITORING AND CONTROL |
| 26 09 14 SCADA MONITORING SYSTEM |
| 27 08 00 COMMSSIONING OF COMMUNICATIONS SYSTEMS |
| 28 08 00 COMMSSIONING OF ELECTRONIC SAFETY AND SECURITY SYSTEMS |
| 33 08 00 COMMISSIONING OF SITE UTILITY SYSTEMS |
| APPENDIX C - SITE ANALYSIS CONTEXT DRAWINGS |
| APPENDIX D - 2015 VA CFM PHYSICAL SECURITY DESIGN MANUAL |
| APPENDIX E - SPACE PROGRAM FOR DESIGN AND ROOM GUIDEPLATES |
| APPENDIX F - CONCEPTUAL PLANNING DIAGRAMS |
| APPENDIX G - LEGACY MEDICAL CENTER SYSTEMS TIE-IN MATRIX |
| APPENDIX H - 2014 TRANSPORTATION AND LOGISTICS REPORT & PNEUMATIC TUBE SYSTEM |
| APPENDIX I - LEED OWNER'S PROJECT REQUIREMENTS |
| 17-R-0002 Amendment 0003 Volume III (Phase II) |
| Phase Two - Volume 3 of 3 |
| Table of Contents |
| APPENDIX J - SITE PHASING & CPM SCHEDULE |
| APPENDIX K - 2014 SITE BOUNDARY, TOPOGRAPHIC AND UTILITY SURVEYS |
| APPENDIX L - GEOTECHNICAL & GEOPHYSICAL REPORTS |
| APPENDIX M - HVAC UTILITY SYSTEM CONNECTIONS |
| APPENDIX N - FIRE PROTECTION |
| APPENDIX O - WATER QUALITY REPORTS, WELL TESTS and CIVIL SITE POTABLE & SANITARY PLAN |
| APPENDIX P - EXISTING SITE UTILITY INFORMATION |
| APPENDIX Q - CIVIL SITE LIFT STATION INFORMATION |
| APPENDIX R - SITE ELECTRICAL / IT/COMMUNICATIONS & SECURITY SYSTEMS |
| APPENDIX S - EXISTING BUILDING 54 GENERATOR PLANT - |
| APPENDIX T - EXISTING BUILDING 1 - HAZARDOUSE MATERIALS DRAWINGS |
| APPENDIX U - EQUIPMENT INFORMATION |
| APPENDIX V - INTERIOR DESIGN INFORMATION |
| APPENDIX W - EXISTING EXTERIOR SIGNAGE INFORMATION |
| APPENDIX X - ENVIRONMENTAL INFORMATION |
| APPENDIX Y - INDEX OF ELECTRONIC EXISITNG BUILDING INFORMATION |
| APPENDIX Z - LARGE FORMAT SITE AND BUILDING DRAWINGS |
File details come from the government source that posted it. Updated .