This document is an electrical power plan drawing for a Legionella Eradication project at the Louis A. Johnson VA Medical Center in Clarksburg, WV. The second floor power plan details four key electrical modifications: (1) installing a new 120V circuit with a 20A/1P breaker to power a new water heater, (2) adding a 208V circuit with a 20A/2P breaker for a new water temperature monitoring system, (3) providing another 208V circuit with a 20A/2P breaker for new recirculation pumps CA-P-01 and CA-P-02, and (4) powering a new bottle filling station using an existing water fountain circuit. The drawing is part of bid documents dated September 12, 2025, with the VA's Office of Construction and Facilities Management overseeing the project, and Apogee Consulting Group serving as the consulting engineers.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
FI
G
FI
M
E
E
M
G
FI
MECHANICAL
SERVICE
ELEVATOR
LOBBY
S-1
S-1
P-1
P-1
P-2
P-2
OFFICE
OFFICE
OFFICE
ELECTRICAL
MECH
WAITING
2190A
TLT.
DRESS
DRESS
DRESS
TLT.
TOILET
SOIL
SUPPLY
SERVER
2201 2202
READING
ROOM
VESTIBU
2204C
EQUIP
2204A
CT SCAN
TLT
2200A
X-RAY
X-RAY
TLT
2198A
WAITING
2190A
ELEC.
TEL.
STAIR H
EXISTING
PANEL '1-2LNB'
CA-WTMS-10
CA-WTMS-9
CA-WTMS-5
'1-2LNB'- 19,21
'1-2LNB'- 20,22
F J L M N O
C
D
G
H
K
L-
M-
N-
P-611
P-606
E P
C
/1 EP102E
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:4
P
M C
U s e rs
\l s ta rn e s \D o c u m e n ts \E
-1
-V A
C la rk s b u rg
-L e g io n e lla
E ra d ic a ti o n
B
L D
G ls ta rn e s C
B U
M B
.r v t
EP102D
SECOND FLOOR POWER PLAN - CLIN
ADD - EAST
12 22LAS
ERADICATE LEGIONELLA
LOUIS A. JOHNSON VA MEDICAL
CENTER 1 MEDICAL CENTER DRIVE
CLARKSBURG, WV 23601 SEPTEMBER 12, 2025
BID DOCUMENTS
540-20-10322-144
GRG
Scale: 1/8" = 1'-0"
SECOND FLOOR POWER PLAN - CLIN ADD - EAST
1 PROVIDE NEW 120V CIRCUIT WITH NEW 20A/1P
BREAKER FROM PANEL '1-2LNB' TO POWER NEW
WATER HEATER 'CA-DWH-01'. COORDINATE
LOCATION OF EQUIPMENT WITH MECHANICAL
DRAWINGS.
2 PROVIDE NEW 208V CIRCUIT WITH NEW 20A/2P
BREAKER FROM PANEL '1-2LNB' TO POWER NEW
WATER TEMPERATURE MONITORING SYSTEM.
COORDINATE LOCATION OF EQUIPMENT WITH
MECHANICAL DRAWINGS.
3 PROVIDE NEW 208V CIRCUIT WITH NEW 20A/2P
BREAKER FROM PANEL '1-2LNB' TO POWER NEW
RECIRCULATION PUMPS CA-P-01 AND CA-P-02.
COORDINATE LOCATION OF EQUIPMENT WITH
MECHANICAL DRAWINGS.
4 NEW BOTTLE FILLING STATION TO BE POWERED
BY EXISTING WATER FOUNTAIN CIRCUIT AND
RECEPTACLE.
N O
R T
H
0 4 8 16
A. THE CONTRACTOR SHALL COORDINATE THE FINAL
PLACEMENT OF THE RECEPTACLES AND
EQUIPMENT WITH THE MECHANICAL DRAWINGS.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
1 ADDENDUM 03 09/12/2025
Docusign Envelope ID: 9914C1CA-6D38-4C12-A070-3A2D053482BB
9/15/2025
| Sheets |
| EP102D - SECOND FLOOR POWER PLAN - CLIN ADD - EAST |
| 2025-09-15T08:50:29-0700 | |
| Digitally verifiable PDF exported from www.docusign.com |
File details come from the government source that posted it. Updated .