36C24518B0233-007.pdf
PDF 3 MB Posted
- Attached to
- CONST DOM CLINIC & CLC ADMIN PROJ 613-121 Federal contract opportunity
- Solicitation number
- 36C24518B0233
About this file
36C24518B0233 5 Plumbing Drawings.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24518C0215-000.docx | DOCX document | |
| 36C24518B0233-0001001.pdf | ||
| 36C24518B0233-0001000.docx | DOCX document | |
| 36C24518B0233-009.pdf | ||
| 36C24518B0233-008.pdf | ||
| 36C24518B0233-001.docx | DOCX document | |
| 36C24518B0233-002.pdf | ||
| 36C24518B0233-010.pdf | ||
| 36C24518B0233-003.pdf | ||
| 36C24518B0233-013.pdf | ||
| 36C24518B0233-012.pdf | ||
| 36C24518B0233-011.pdf | ||
| 36C24518B0233-005.pdf | ||
| 36C24518B0233-004.pdf | ||
| 36C24518B0233-006.pdf | ||
| 36C24518B0233-000.docx | DOCX document |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RP-
PLUMBING CIRCULATING PUMP SCHEDULE
MARK VOLTAGE / PHASETYPE
MOTOR
H.P.
TOTAL HEAD
IN FEET
GALLONS
PER MINUTE
LOCATION
SHOCK ABSORBER SCHEDULE
5020ABSORBOTRON TYPE NO. 503050105005 5040 5050
FLOOR DRAIN SCHEDULE
LOCATION SEWERSIZETYPE REMARKS
RP-
RP-
RP-
DOMESTIC WATER CALCULATIONS
WSFU FLUSH VALVESIZE
GPM
WSFU FLUSH TANKFLUSH
VALVE
FLUSH
TANK
DOMESTIC WATER HEATER SCHEDULE
TYPE
RECOVERY
AT 48°F RISE
MARK CAPACITY LOCATIONKW VOLTAGE/PHASE
WH-
WH-
1. BASIS OF DESIGN: GRUNDFOS. MODEL: MAGNA3 32-60F 98126822.
2. PUMP MOTOR SHALL BE LISTED BY THE NATIONAL RECOGNIZED TEST LABORATORY (NRTL) FOR U.S.
1. FIXTURE UNIT VALUES BASED ON THE VAMC PLUMBING DESIGN MANUAL SIZING CHARTS.
2. MAX VELOCITY FOR HOT WATER - 5 FT/SEC, FOR COLD WATER 6 FT/SECOND.
1. WH-1 BASIS OF DESIGN: MANUFACTURE EEMAX ACCUMIX MT004120T.
2. WH-2 BASIS OF DESIGN: MANUFACTURE EEMAX ACCUMIX MB004120T.
3. WATER HEATER SHALL HAVE MINIMUM FLOW 0.3 GPM AND MAXIMUM FLOW 2.5 GPM.
4. SET WATER HEATER OUTLET TEMPERATURE AT 110 DEGREES F.
5. CONTRACTOR SHALL PROVIDE 1070 MIXING VALVES OR ASSE 1070 COMPLAINT ELECTRIC TANKLESS
WATER HEATER IF BASIS OF DESIGN IS NOT INSTALLED.
1. J.R. SMITH MANUFACTURING COMPANY NUMBER SHOWN. JOSAM, ZURN, OR APPROVED EQUAL IS
ACCEPTABLE.
S = SANITARY
ST = STORM
C = FINISHED AREA
D = LATEX MASTIC/THIN SET TILE
1. REFER TO DRAWINGS FOR LOCATION OF FLOOR DRAIN.
NOTES:
NOTES:
NOTES:
NOTES:
LEGEND: TYPE:
NOTES:
WATER CLOSET,
FLUSH VALVE,
PUBLIC
1 AND 7
LAVATORY, PUBLIC 2 AND 7
SERVICE SINK 6
SINK, CRS 3 AND 7
SINK, CRS 4 AND 7
ELECTRIC WATER
COOLER
5 AND 7
WALL HYDRANT
WATER SUPPLY BOX
UNIT
FLOOR DRAIN
1. WALL HUNG, VITREOUS CHINA, SIPHON JET, FLUSH VALVE, 1.28 GPF MAXIMUM.
2. WALL HUNG, SINGLE LEVER HANDLE CONTROL FAUCET, 0.35 GPM MAXIMUM LAMINAR FLOW DEVICE.
PROVIDE AND INSTALL NEW ELECTRIC TANKLESS WATER HEATER (WH-1) UNDER LAVATORY.
3. COUNTER-TOP MOUNT, STAINLESS STEEL, DOUBLE COMPARTMENT, SWING ARM FAUCET WITH SINGLE
LEVER CONTROL, 0.5 GPM MAXIMUM LAMINAR FLOW DEVICE. PROVIDE AND INSTALL NEW ELECTRIC
TANKLESS WATER HEATER (WH-2) UNDER COUNTER IN CABINET SPACE.
4. COUNTER-TOP MOUNT, STAINLESS STEEL, SINGLE COMPARTMENT, GOOSENECK FAUCET WITH
ELECTRONIC SENSOR OPERATION, 0.5 GPM MAXIMUM LAMINAR FLOW DEVICE. PROVIDE AND INSTALL
NEW ELECTRIC TANKLESS WATER HEATER (WH-2) UNDER COUNTER IN CABINET SPACE.
5. WALL HUNG, STAINLESS STEEL FOUNTAIN, MECHANICALLY COOLED, DUAL HEIGHT, WITH BOTTLE
FILLER.
6. PROVIDE AND INSTALL NEW ELECTRIC TANKLESS WATER HEATER (WH-2) ON WALL.
7. HANDICAPPED FIXTURE. FIXTURE SHALL MEET THE AMERICANS WITH DISABILITIES ACT AND THE
BARRIER-FREE HEALTHCARE INITIATIVE REQUIREMENTS.
WATER CLOSET,
FLUSH VALVE,
PUBLIC
LAVATORY, PUBLIC 4
SERVICE SINK 1
SINK, CRS 1
SINK, CRS 6
ELECTRIC WATER
COOLER
WALL HYDRANT 2
WATER SUPPLY BOX
UNIT
FLOOR DRAIN 2
58.00 GPM.
54.00 GPM
19.60 GPM
4" DRAINAGE 2-1/2" DCWS ~ 1-1/4" DHWS
WATER CLOSET,
FLUSH VALVE,
PUBLIC
LAVATORY, PUBLIC 3
SERVICE SINK 1
SINK, CRS 8
ELECTRIC WATER
COOLER
WALL HYDRANT 2
FLOOR DRAIN 2
54.00 GPM
50.00 GPM
19.00 GPM
4" DRAINAGE 2" DCWS ~ 1-1/4" DHWS
P-103
P-401
P-502
P-524
P-528
P-609
P-801
P-812
FD-1
P-103
P-401
P-502
P-524
P-528
P-609
P-801
P-812
FD-1
P-103
P-401
P-502
P-528
P-609
P-801
FD-1
MARK FIXTURE DFU
DCWS
WSFU
DHWS
WSFU
TOTAL
WSFU
CONNECTION PIPE SIZE
REMARKS
WASTE VENT DCWS DHWS
4.00 10.00 - 10.00 3.00 2.00 1.00 -
1.00 1.50 1.50 2.00 1.50 1.50 0.375 0.375
2.00 3.00 3.00 4.00 3.00 1.50 0.50 0.50
1.00 1.50 1.50 2.00 1.50 1.50 0.375 0.375
1.00 1.50 1.50 2.00 1.50 1.50 0.375 0.375
0.50 0.25 - 0.25 1.50 1.50 0.375 -
2.00 - - - 2.00 1.50 - -
MARK FIXTURE QTY
DRAINAGE FU DOMESTIC WATER FU
EACH TOTAL
COLD
WATER
EACH
COLD
WATER
TOTAL
HOT
WATER
EACH
HOT
WATER
TOTAL
WATER
SUPPLY
EACH
WATER
SUPPLY
TOTAL
4.00 16.00 10.00 40.00 - - 10.00 40.00
1.00 4.00 1.50 6.00 1.50 6.00 2.00 8.00
2.00 2.00 3.00 3.00 3.00 3.00 4.00 4.00
3.00 3.00 1.50 1.50 1.50 1.50 2.00 2.00
3.00 18.00 1.50 9.00 1.50 9.00 2.00 12.00
0.50 1.00 0.25 0.50 - - 0.25 0.50
2.00 4.00 - - - - - -
48.00 60.00 19.50 66.50
DOMESTIC WATER SUPPLY 66.50 WSFU =
DOMESTIC COLD WATER SUPPLY 60.00 WSFU =
DOMESTIC HOT WATER SUPPLY 19.50 WSFU =
PIPE SIZE:
MARK FIXTURE QTY
DRAINAGE FU DOMESTIC WATER FU
EACH TOTAL
COLD
WATER
EACH
COLD
WATER
TOTAL
HOT
WATER
EACH
HOT
WATER
TOTAL
WATER
SUPPLY
EACH
WATER
SUPPLY
TOTAL
4.00 12.00 10.00 30.00 - - 10.00 30.00
1.00 3.00 1.50 4.50 1.50 4.50 2.00 6.00
2.00 2.00 3.00 3.00 3.00 3.00 4.00 4.00
3.00 24.00 1.50 12.00 1.50 12.00 2.00 16.00
0.50 0.50 0.25 0.25 - - 0.25 0.25
2.00 4.00 - - - - - -
45.50 49.75 19.50 56.25
DOMESTIC WATER SUPPLY 56.25 WSFU =
DOMESTIC COLD WATER SUPPLY 49.75 WSFU =
DOMESTIC HOT WATER SUPPLY 19.50 WSFU =
PIPE SIZE:
PLUMBING FIXTURE SCHEDULE
NOTES:
CLC ADMIN. FIXTURE UNIT CALCULATION
DOM. CLINIC FIXTURE UNIT CALCULATION
1 IN-LINE 1/12 115 / SINGLE 8 3 MECH. 501D-102
P.D.I. SYMBOLS A B C D E F
FIXTURE UNIT RATING 1-11 12-32 33-60 61-113 114-154 155-330
MECHANICAL SPACE FD-E 4" S 1
HAC FD-C OR D 3" S 1
2 IN-LINE 1/12 115 / SINGLE 8 3 MECH. 501D-102
3 IN-LINE 1/12 115 / SINGLE 8 3 MECH. 502F-128
4 IN-LINE 1/12 115 / SINGLE 8 3 MECH. 502F-128
1/2" 3 3 - 1
3/4" 6 6 - 2
1" 15 15 1 10
1-1/4" 21 23 6 25
1-1/2" 30 34 12 60
2" 61 64 45 180
2-1/2" 75 94 275 500
1 TANKLESS 0.5 GPM ELECTRIC 120 / SINGLE P-4013.5 KW
2 TANKLESS 0.5 GPM ELECTRIC 120 / SINGLE P-502 P-524, P-5283.5 KW
VENT THROUGH ROOF - DIAGRAMMATIC
WATER HAMMER ARRESTOR
'A'
DOMESTIC COLD WATER
DOMESTIC HOT WATER (130°F)
DOMESTIC COLD WATER RECIRCULATING
SOIL, WASTE OR SANITARY SEWER
BALL VALVE
BALANCING VALVE
UNION
OVERFLOW RAINLEADER PIPINGOF
RAINLEADER PIPINGRL
VENT PIPING
PIPE TURNING DOWN
PIPE TURNING UP
PITCH DOWN IN DIRECTION OF ARROW
NATURAL GAS PIPINGG
AUTOMATIC AIR VENT
VALVES AND ACCESSORIES
AUTOMATIC FLOW CONTROL VALVE
BACKFLOW PREVENTER (BFD)
BALL VALVE
BUTTERFLY VALVE
CAPPED PIPE
CHECK VALVE
CONCENTRIC REDUCER
DIRECTION OF FLOW
ECCENTRIC REDUCER
FLANGED CONNECTION
FLEXIBLE CONNECTION
FLOW METER
GENERAL
LEGEND
INDICATES ITEM TO BE PROVIDED
FLOOR DRAIN WITH DEEP SEAL P-TRAPFD
CLEANOUT, GRADE TYPE
GCO
CLEANOUT, FLOOR TYPE
FCO
CLEANOUT
CO
BRANCH SIDE CONNECTION
BRANCH TOP CONNECTION
BRANCH BOTTOM CONNECTION
STORM DRAINAGE PIPINGSD
SAN
ABBREVIATIONS
GENERAL NOTES
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
PLUMBING LEGEND, GENERAL NOTES, AND
SCHEDULES
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
P001
613-121
June 27, 2018 GTK DLB
AC ABOVE CEILING
ADA AMERICANS WITH DISABILITIES ACT
ARCH ARCHITECTURAL
BF BELOW FLOOR
BG BELOW GRADE
DCWR DOMESTIC COLD WATER RETURN
DCWS DOMESTIC COLD WATER SUPPLY
DFU DRAINAGE FUXTURE UNITS
DIA DIAMETER
DN DOWN
DWG DRAWING
EX EXISTING
FCO CLOOR CLEANOUT
FU FIXTURE UNITS
GPM GALLONS PER MINUTE
HB HOSE BIBB
kW KILLOWATTS
MISC MISCELLANEOUS
MV MIXING VALVE
NIC NOT IN CONTRACT
OD OVERFLOW DRAIN
RD ROOF DRAIN
RL RAINLEADER
RP RECIRCULATION PUMP
TYP TYPICAL
WSFU WATER SUPPLY FIXTURE UNITS
1. PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT REQUIRED FOR THE COMPLETION AND
OPERATION OF ALL SYSTEMS IN THIS SECTION OF WORK IN ACCORDANCE WITH CONTRACT PLANS, SPECIFICATIONS AND ALL APPLICABLE STATE AND LOCAL CODES.
2. PROVIDE A COMPLETE SYSTEM OF HOT AND COLD WATER, AND WASTE AND VENT PIPING TO ALL
FIXTURES WITHIN THE BUILDING.
3. ALL WATER, SOIL, WASTE, AND VENT PIPING LINES SHALL BE CONCEALED IN THE BUILDING
CONSTRUCTION, EXCEPT WHERE INDICATED OTHERWISE.
4. COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING-IN PLUMBING FIXTURES.
5. ROUTING OF ALL PIPING SHALL BE COORDINATED WITH OTHER TRADES.
6. FIXTURES AND EQUIPMENT ARE INDICATED IN THE PLUMBING FIXTURE SCHEDULE, WATER HAMMER ARRESTOR SCHEDULE, PUMP SCHEDULE, AND AS SPECIFIED IN THE SPECIFICATIONS AS A GUIDE FOR GENERAL QUALITY AND PERFORMANCE DESIRED. FIXTURES AND EQUIPMENT BY OTHERS ARE
ACCEPTABLE PROVIDED THEY ARE OF THE SAME TYPE, QUALITY AND OPERATION.
7. ALL PLUMBING VENTS WITHIN A 15'-0" RADIUS OF ANY ROOF TOP UNIT OR FRESH AIR INTAKE SHALL
BE OFFSET TO CLEAR OUTSIDE THE RADIUS.
8. PROTECT COPPER PIPING AGAINST CONTACT WITH MASONRY OR DISSIMILAR METALS. HANGERS, SUPPORTS, ANCHORS AND CLIPS SHALL BE COPPER OR COPPER PLATED.
9. BASIS-OF -DESIGN FIXTURES AND EQUIPMENT LISTED IN THE SCHEDULES, ON THIS SHEET, BY
MANUFACTURER AND MODEL NUMBER INDICATE GENERAL QUALITY AND PERFORMANCE
CHARACTERISTICS REQUIRED. ITEMS HAVING EQUAL CHARACTERISTICS BY OTHER
MANUFACTURERS WILL BE ACCEPTABLE.
10. PROVIDE SHUT-OFF VALVES AND BACKFLOW PREVENTION DEVICES AT ALL CONNECTIONS TO
NON-POTABLE WATER SYSTEMS.
11 THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND NOT TO BE SCALED. FIELD VERIFY ALL
DIMENSIONS, PIPE SIZES, LOCATIONS, AND INVERTS. REFER TO ARCHITECTURAL DRAWINGS FOR
DIMENSIONS AND LOCATIONS OF ALL PLUMBING FIXTURES.
12 PROVIDE CLEANOUTS AS REQUIRED BY THE INTERNATIONAL PLUMBING CODE, LOCAL CODES, VA
PLUMBING DESIGN MANUAL, AT BOTTOM OF STACKS, AND WHERE HORIZONAL SANITARY SEWER
PIPING CHANGES DIRECTION OVER 45 DEGREES.
13 NEW 2 INCH SANITARY SEWER PIPING SHALL BE SLOPED A MINIMUM OF TWO PERCENT,
ONE-QUARTER INCH PER FOOT. NEW 3 INCH, 4 INCH, AND 6 INCH SANITARY SEWER PIPING SHALL BE
SLOPED A MINIMUM OF ONE PERCENT, ONE-EIGHTH INCH PER FOOT.
14 DOMESTIC COLD WATER SUPPLY, DOMESTIC COLD WATER RETURN, HORIZONTAL STORM DRAIN
PIPING SHALL BE INSULATED.
501D & 502F
F
2 2
2424244 2
6"
INV.EL.: 504.50'
8"
4778.97 S.F.
134.19 GPM
BG
INV.EL.: 503.87'
6"
3505.71 S.F.
193.52 GPM
BG
SANSAN SAN
S A
N
S A
N
S A
N
S A
N
SAN
S A
N
S D
SAN
SD
SD
SD SD SD SD SD
S D
1 3 3.1 3.4 4 4.5 4.8 5 5.3 6 7.4E 6.5 9E 7 7.5 8 12E 12.2E 9 9.7 9.8 9.9 14E 10 10.5 11 15E 12 16E
K
I
H
G.5
G
F
C.4
C.2
C
B.5
B
A
RE
QE
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
FOUNDATION WASTE, DRAIN, AND VENT
PIPING PLAN - CLC ADMIN
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL101
613-121
June 27, 2018 GTK DLB
1. 2"V-UP.
2. 2"SS-UP.
3. 3"SS-UP.
4. 4"SS-UP TO FIXTURE P-103 WATER CLOSET CARRIER.
5. 3"SS-UP TO FIXTURE P-502.
6. 3"SS-UP TO FLOOR DRAIN TYPE C OR TYPE D.
7. 4"SS-UP TO FLOOR DRAIN TYPE E.
8. 4"SD-UP.
9. 6"SD-UP.
10. 8"SD-UP.
11. 4"SS-UP TO FLOOR CLEANOUT.
12. 4"SD-UP TO FLOOR CLEANOUT.
13. 1/2" TRAP PRIMER PIPING UP AND ROUTE TO FLOOR DRAIN.
14. REFER TO CIVIL FOR CONTINUATION OF PIPING.
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
1/8" = 1' - 0" 0 5' 10' 15' 30'
X
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING CODE,
LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING DESIGN
GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING CHANGES
DIRECTIONS OVER 45 DEGREES.
B. 2" SANITARY SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. 3" THRU 6" SANITARY
SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT, ONE-
EIGHTH INCH PER FOOT.
C. REFER TO ISOMETRIC RISER DIAGRAM - WASTE DRAIN, AND VENT PIPING
ON DRAWING PL201 FOR PIPE SIZES.
TRUE
NORTH
PLAN
NORTH
501D
1/8" = 1'-0"
FOUNDATION PLAN - CLC ADMIN
EE AA
FF DD CC BB
21.4
SANSAN
SAN
SAN
SANSAN
S A
N
SAN
SAN
S A
N
SAN
INV.EL.: 503.27'
6"
1723.28 S.F.
48.39 GPM
INV.EL.: 504.11'
6"
SD
S D
S A
N
SAN
S D
S D S D
INV.EL.: 503.27'
6"
3906.60 S.F.
109.66 GPM
BG
BG
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
FOUNDATION WASTE, DRAIN, AND VENT
PIPING PLAN - DOM CLINIC
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL102
613-121
June 27, 2018 GTK DLB
1/8" = 1'-0"
FOUNDATION PLAN - DOM CLINIC
1. 4"SS-UP TO CLEANOUT.
2. 2"SS-UP.
3. 3"SS-UP.
4. 4"SS-UP.
5. 3"SS-UP TO FIXTURE P-502.
6. 3"SS-UP TO FLOOR DRAIN TYPE C OR TYPE D.
7. 4"SS-UP TO FLOOR DRAIN TYPE E.
8. 3"V-UP.
9. 4"SD-UP.
10. 1/2" TRAP PRIMER PIPING UP AND ROUTE TO FLOOR DRAIN.
11. REFER TO CIVIL FOR CONTINUATION OF PIPING.
12. 2"SS-UP TO FLOOR DRAIN TYPE C OR TYPE D.
1/8" = 1' - 0" 0 5' 10' 15' 30'
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING CODE,
LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING DESIGN
GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING CHANGES
DIRECTIONS OVER 45 DEGREES.
B. 2" SANITARY SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. 3" THRU 6" SANITARY
SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT, ONE-
EIGHTH INCH PER FOOT.
C. REFER TO ISOMETRIC RISER DIAGRAM - WASTE DRAIN, AND VENT PIPING
ON DRAWING PL201 FOR PIPE SIZES.
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
TRUE
NORTH
PLAN
NORTH
502F
DNDN
DN
DN
H
F
K
A
3.41
I
4.8
QE
10.59E 12.2E 9.94.5 5.3 6.5 7.5 8.4
CORR.
501D-105
ELECTRICAL
501D-104
LOADING
501D-103
MECHANICAL
501D-102
IT
501D-101
ENTRANCE
501D-100
CORRIDOR
501D-C1
ADMIN. SUPP.
501D-107
WAITING
501D-106
OFF. / EX.
501D-111
OFF. / EX.
501D-109
CONFERENCE
ROOM
501D-122
STOR.
501D-111A
CORRIDOR
501D-C2
N. CASE MAN.
501D-108
OFF. / EX.
501D-110
OFF. / EX.
501D-112
N. CASE MAN.
501D-113
PSYCHOL.
501D-114
G. FELLOW
501D-115
G. FELLOW
501D-116
COPY /
WORKROOM
501D-120
CUBICLES
501D-128
HAC
501D-134
CORR. A
501D-C3
LANDING
501D-136
ENTRANCE
501D-131
SERV. CHIEF.
501D-130
AD. ASST.
501D-129
STOR.
501D-129A
CORR. B
501D-C4
BUS. MAN.
501D-127
PROG. MAN.
501D-126
OFFICE/EXAM
501D-125
OFFICE/EXAM
501D-124
N. ADMIN.
501D-123 LIGHTWELL
501C-125A
CONNECTOR
RAMP
501D-C5
STAFF T.
501D-133
GUEST T.
501D-117
BREAK ROOM
501D-121
CONNECTOR
RAMP
501D-C5
BUILDING 501
P-103
P-401
P-103
P-401P-401
P-103
P-401
P-103
P-609
P-609
P-502 P-528 P-528
P-528 P-528
P-528
P-528
AC
AC AC
AC
AC
AC
AC
AC
AC
FCO
STAFF T.
501D-118
CORR. B
501D-C4
CORRIDOR
501D-C2
AC
AC
AC
9 8
10 8
8 10 8
P-524
FCO
16AC 1516
SD SD SD SD
SDSDSD SD
S D
OD OD OD OD
OD
OD OD OD
AC
AC
AC
AC
AC
FCOAC
AC
AC
AC
P-812
1 3 3.1 3.4 4 4.5 4.8 5 5.3 6 7.4E 6.5 9E 7 7.5 8 12E 12.2E 9 9.7 9.8 9.9 14E 10 10.5 11 15E 12 16E
K
I
H
G.5
G
F
C.4
C.2
C
B.5
B
A
RE
QE
3/4" 3/4"
RP-1
RP-2
BALL VALVE
TYPICAL
CHECK-VALVE
TYPICAL
36" A.F.F.
ANALOG
PRESSURE
GAUGE
TEMPERATURE
SENSOR AND
PETE'S PLUG
ANALOG
THERMOMETER
PRESSURE
SENSOR
FLOW
SENSOR
F
2 1/2"
REDUCED
PRESSURE
BACKFOW
PREVETER
NEW FIRE
PROTECTION
ENTRANCE RISER
2 1/2" 2 1/2"
ASSE 1070
ELECTRIC
TANKLESS
WATER
HEATER
WASTE
PIPING
SINK/
LAVATORY
DOMESTIC
HOT WATER
SUPPLY 110 F
DOMSTIC
COLD WATER
SUPPLY
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
FIRST FLOOR PLUMBING PIPING PLAN - CLC
ADMIN
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL103
613-121
June 27, 2018 GTK DLB
1/8" = 1'-0"
FIRST FLOOR PIPING PLAN - CLC ADMIN
1. CONNECT DOMESTIC COLD WATER SUPPLY TO FIRE PROTECTION SUPPLY
RISER ENTRANCE BELOW DOUBLE CHECK VALVE ASSEMBLY. REFER TO
DETAIL ON THIS DRAWING.
2. PROVIDE AND INSTALL DUPLEX REDUCED PRESSURE BACKFLOW
PREVENTER AT APPROXIMATE LOCATION INDICATED. REFER TO DETAIL
ON THIS DRAWING.
3. PROVIDE AND INSTALL ANALOG THERMOMETER, TEMPERATURE SENSOR,
AND PETE'S PLUG ON DOMESTIC COLD WATER PIPING AT APPROXIMATE
LOCATION INDICATED. SENSORS SHALL BE CONNECTED TO BUILDING
CONTROLS SYSTEM. COORDINATE WITH THE CONTROLS CONTRACTOR.
4. PROVIDE AND INSTALL BALANCING VALVE (CIRCUIT SETTER) ABOVE
CEILING AT APPROXIMATE LOCATION INDICATED. DOMESTIC WATER
CIRCULATION CIRCUITS SHALL BE TESTED, BALANCED, AND CERTIFIED BY
A COMPANY WHO SPECIALIZES IN SUCH SERVICES. A TEST AND BALANCE
REPORT SHALL BE PROVIDED INDICATING A MINIMUM OF 3 GPM FLOW OF
DOMESTIC COLD WATER.
5. PROVIDE AND INSTALL COLD WATER CIRCULATING PUMP RP-1 AND RP-2.
CONNECT TO DDC TIMED CONTROLLED ALTERNATING STARTER. REFER
TO CIRCULATING PUMP SCHEDULE ON DRAWING P001 AND DETAIL ON THIS
DRAWING.
6. PROVIDE AND INSTALL 3" FLOOR DRAIN TYPE C OR TYPE D. PROVIDE TRAP
PRIMER DEVICE.
7. PROVIDE AND INSTALL 4" FLOOR DRAIN TYPE E. PROVIDE TRAP PRIMER
DEVICE.
8. 2"SS-DN.
9. 3"SS-DN.
10. 4"SS-DN.
11. 2"V-DN AND 3"V-UP TO VENT THRU ROOF.
12. CHECK VALVE.
13. 3"V-UP TO VENT THRU ROOF.
14. 2"V-DN.
15. 3"SD-UP TO ROOF DRAIN.
16. 3"OD-UP TO EMERGENCY ROOF DRAIN.
17. 4"SD-UP TO ROOF DRAIN.
18. 4"OD-UP TO EMERGENCY ROOF DRAIN.
19. 6"SD-DN.
20. 8"SD-DN.
21. 6" DOWNSPOUT NOZZLE. MOUNT CENTERLINE AT 113" ABOVE FINISHED
GRADE.
22. 8" DOWNSPOUT NOZZLE. MOUNT CENTERLINE AT 113" ABOVE FINISHED
GRADE.
23. 4"SD-UP TO ROOF DRAIN.
24. 4"SD-DN.
25. PROVIDE AND INSTALL NEW TRAP PRIMER DEVICE AND ALL PIPING TO
FLOOR DRAIN.
26. PROVIDE AND INSTALL NEW 3/4" NON-FREEZE WALL HYDRANT (P-801).
MOUNT CENTERLINE OF WALL HYDRANT AT 24" ABOVE FINISHED GRADE.
NO SCALE
CIRCULATING PUMP DETAIL - CLC ADMIN
NO SCALE
BACKFLOW PREVENTER DETAIL - CLC ADMIN
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
1/8" = 1' - 0" 0 5' 10' 15' 30'
X
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING CODE,
LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING DESIGN
GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING CHANGES
DIRECTIONS OVER 45 DEGREES.
B. 2" SANITARY SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. 3" THRU 6" SANITARY
SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT, ONE-
EIGHTH INCH PER FOOT.
C. WASTE DRAIN, AND VENT PIPING REFER TO ISOMETRIC RISER DIAGRAM ON
DRAWING PL201 FOR SANITARY SEWER/WASTE PIPE SIZES.
D. DOMESTIC WATER DISTRIBUTION REFER TO ISOMETRIC RISER DIAGRAM
ON DRAWING PL301 FOR DOMESTIC WATER PIPE SIZES.
E. ALL HORIZONAL STORM DRAIN PIPING, OVERFLOW DRAIN PIPING, RAIN
WATER LEADER, BOTTOM OF ROOF DRAIN, AND EMERGENCY ROOF DRAIN
ABOVE CEILING SHALL ME INSULATED.
TRUE
NORTH
PLAN
NORTH
501D
NO SCALE
WATER HEATER CONNECTION DETAIL- CLC ADMIN
FF
DD CC AAEE
BB
21.4
MANAGER
502F-123
PSYCH.
502F-125
PSYCH.
502F-127
PSYCH.
502F-129
CORR. B
502F-C2
PA OFFICE
502F-126
MECHANICAL
502F-128
ELECT
502F-130
N. ASSESS.
502F-114
REC. THER.
502F-116
DIETICIAN
502F-118
IT
502F-120
SOC. WORK.
502F-121
PEER SUPP.
502F-119
DOM SUPV.
SCREEN.
502F-117
DOM STAFF
SCREENER
502F-115
CORR. A
502F-C1
DOM SCREENING
CLERK
502F-113
VESTIBULE
502F-110
N. ASSESS.
502F-109
N. ASSESS.
502F-108
TRIAGE
502F-104
CHECK IN
502F-102
WAITING
502F-103
N. STATION
502F-107
MEDS
502F-106
STAFF T.
502F-124
HAC
502F-122
SPEC. VEST.
502F-111
P-528
P-528
P-103
P-401
P-401
P-103
P-502
P-103 P-401
P-528
WCO
P-528
N. STATION
502F-105
LOBBY
502F-100
SPEC. T.
502F-112
FCO
P-528
P-528 P-528 P-528
ACAC
AC
AC
AC
AC
AC
AC
AC
AC
P-609
FCO AC
FCO
FCO
16 AC
AC
15 OD OD
O D O
D O
D
O D
O D
SD
1818 18
AC
RP-3
RP-4
3/4"3/4"
BALL VALVE
TYPICAL
CHECK-VALVE
TYPICAL
56" A.F.F.
ANALOG
PRESSURE
GAUGE
TEMPERATURE
SENSOR AND
PETE'S PLUG
ANALOG
THERMOMETER
PRESSURE
SENSOR
FLOW
SENSOR
2"
2"
NEW FIRE
PROTECTION
ENTRANCE
RISER
2"
REDUCED
PRESSURE
BACKFLOW
PREVENTER
ASSE 1070
ELECTRIC
TANKLESS
WATER
HEATER
WASTE
PIPING
SINK/
LAVATORY
DOMESTIC
HOT WATER
SUPPLY 110 F
DOMSTIC
COLD WATER
SUPPLY
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
FIRST FLOOR PLUMBING PIPING PLAN - DOM
CLINIC
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL104
613-121
June 27, 2018 GTK DLB
1/8" = 1'-0"
FIRST FLOOR PIPING PLAN - DOM CLINIC
1. CONNECT DOMESTIC COLD WATER SUPPLY TO FIRE PROTECTION SUPPLY
RISER ENTRANCE BELOW DOUBLE CHECK VALVE ASSEMBLY. REFER TO
DETAIL ON THIS DRAWING.
2. PROVIDE AND INSTALL DUPLEX REDUCED PRESSURE BACKFLOW
PREVENTER AT APPROXIMATE LOCATION INDICATED. REFER TO DETAIL
ON THIS DRAWING.
3. PROVIDE AND INSTALL ANALOG THERMOMETER, TEMPERATURE SENSOR,
AND PETE'S PLUG ON DOMESTIC COLD WATER PIPING AT APPROXIMATE
LOCATION INDICATED. SENSORS SHALL BE CONNECTED TO BUILDING
CONTROLS SYSTEM. COORDINATE WITH THE CONTROLS CONTRACTOR.
4. PROVIDE AND INSTALL BALANCING VALVE (CIRCUIT SETTER) ABOVE
CEILING AT APPROXIMATE LOCATION INDICATED. DOMESTIC WATER
CIRCULATION CIRCUITS SHALL BE TESTED, BALANCED, AND CERTIFIED BY
A COMPANY WHO SPECIALIZES IN SUCH SERVICES. A TEST AND BALANCE
REPORT SHALL BE PROVIDED INDICATING A MINIMUM OF 3 GPM FLOW OF
DOMESTIC COLD WATER.
5. PROVIDE AND INSTALL COLD WATER CIRCULATING PUMP RP-3 AND RP-4.
CONNECT TO DDC TIMED CONTROLLED ALTERNATING STARTER. REFER
TO CIRCULATING PUMP SCHEDULE ON DRAWING P001 AND DETAIL ON THIS
DRAWING.
6. PROVIDE AND INSTALL 3" FLOOR DRAIN TYPE C OR TYPE D. PROVIDE TRAP
PRIMER DEVICE.
7. PROVIDE AND INSTALL 4" FLOOR DRAIN TYPE E. PROVIDE TRAP PRIMER
DEVICE.
8. 2"SS-DN.
9. 3"SS-DN AND 3"V-UP.
10. 4"SS-DN.
11. 4"SS-DN AND 3"V-UP TO VENT THRU ROOF.
12. 2"V-UP TO VENT THRU ROOF.
13. 3"V-DN AND UP TO VENT THRU ROOF.
14. 2"SS-DN AND 3"-UP TO VENT THRU ROOF.
15. 4"RD-UP TO ROOF DRAIN.
16. 4"OD-UP TO EMERGENCY ROOF DRAIN.
17. 4"RD-DN.
18. 4" RAIN WATER NOZZLE. MOUNT CENTERLINE AT 155 INCHES ABOVE
FINISHED GRADE.
19. PROVIDE AND INSTALL NEW TRAP PRIMER DEVICE AND ALL PIPING TO
FLOOR DRAIN.
20. PROVIDE AND INSTALL NEW 3/4" NON-FREEZE WALL HYDRANT (P-801).
MOUNT CENTER OF WALL HYDRANT AT 24" ABOVE FINISHED GRAND.
21. PROVIDE AND INSTALL 2" FLOOR DRAIN TYPE C OR TYPE D. PROVIDE TRAP
PRIMER DEVICE.
NO SCALE
CIRCULATING PUMP DETAIL - DOM CLINIC
NO SCALE
BACKFLOW PREVENTER DETAIL - DOM CLINIC
TRUE
NORTH
PLAN
NORTH
502F
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
X
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING CODE,
LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING DESIGN
GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING CHANGES
DIRECTIONS OVER 45 DEGREES.
B. 2" SANITARY SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. 3" THRU 6" SANITARY
SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT, ONE-
EIGHTH INCH PER FOOT.
C. WASTE DRAIN, AND VENT PIPING REFER TO ISOMETRIC RISER DIAGRAM ON
DRAWING PL201 FOR SANITARY SEWER/WASTE PIPE SIZES.
D. DOMESTIC WATER DISTRIBUTION REFER TO ISOMETRIC RISER DIAGRAM
ON DRAWING PL301 FOR DOMESTIC WATER PIPE SIZES.
E. ALL HORIZONAL STORM DRAIN PIPING, OVERFLOW DRAIN PIPING, RAIN
WATER LEADER, BOTTOM OF ROOF DRAIN, AND EMERGENCY ROOF DRAIN
ABOVE CEILING SHALL ME INSULATED.
NO SCALE
WATER HEATER CONNECTION DETAIL - DOM CLINIC
1/8" = 1' - 0" 0 5' 10' 15' 30'
H
F
K
A
3.4
G.5
I
4.8
QE
10.59E 12.2E 9.94.5 5.3 6.5 7.5 8.4
1706.91 S.F.
47.93 GPM
1679.07 S.F.
47.15 GPM
3375.88 S.F.
94.79 GPM
2633.30 S.F.
73.94 GPM
2145.67 S.F.
60.25 GPM
129.83 S.F.
3.65 GPM
1 3 3.1 3.4 4 4.5 4.8 5 5.3 6 7.4E 6.5 9E 7 7.5 8 12E 12.2E 9 9.7 9.8 9.9 14E 10 10.5 11 15E 12 16E
K
I
H
G.5
G
F
C.4
C.2
C
B.5
B
A
RE
QE
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
ROOF PLAN PLUMBING PIPING PLAN - CLC
ADMIN
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL105
613-121
June 27, 2018 GTK DLB
TRUE
NORTH
PLAN
NORTH
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING
CODE, LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING
DESIGN GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING
CHANGES DIRECTIONS OVER 45 DEGREES.
B. 2" SANITARY SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. 3" THRU 6" SANITARY
SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT, ONE-
EIGHTH INCH PER FOOT.
C. WASTE DRAIN, AND VENT PIPING REFER TO ISOMETRIC RISER DIAGRAM ON
DRAWING PL201 FOR SANITARY SEWER/WASTE PIPE SIZES.
D. ALL HORIZONAL STORM DRAIN PIPING, OVERFLOW DRAIN PIPING, RAIN
WATER LEADER, BOTTOM OF ROOF DRAIN, AND EMERGENCY ROOF DRAIN
ABOVE CEILING SHALL ME INSULATED.
1/8" = 1'-0"
ROOF PLAN - CLC ADMIN
1. 3" VENT THRU ROOF.
2. 3" ROOF DRAIN.
3. 3" EMERGENCY ROOF DRAIN.
4. 4" ROOF DRAIN.
5. 4" EMERGENCY ROOF DRAIN.
1/8" = 1' - 0" 0 5' 10' 15' 30'
X
501D
FF
DD CC AAEE
BB
21.4
3 3 th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
ROOF PLAN PLUMBING PIPING PLAN - DOM
CLINIC
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL106
613-121
June 27, 2018 GTK DLB
1/8" = 1'-0"
ROOF PLAN - DOM CLINIC
1. 3" VENT THRU ROOF.
2. 4" ROOF DRAIN.
3. 4" EMERGENCY ROOF DRAIN.
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING
CODE, LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING
DESIGN GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING
CHANGES DIRECTIONS OVER 45 DEGREES.
B. 2" SANITARY SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. 3" THRU 6" SANITARY
SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT, ONE-
EIGHTH INCH PER FOOT.
C. WASTE DRAIN, AND VENT PIPING REFER TO ISOMETRIC RISER DIAGRAM ON
DRAWING PL201 FOR SANITARY SEWER/WASTE PIPE SIZES.
D. ALL HORIZONAL STORM DRAIN PIPING, OVERFLOW DRAIN PIPING, RAIN
WATER LEADER, BOTTOM OF ROOF DRAIN, AND EMERGENCY ROOF DRAIN
ABOVE CEILING SHALL ME INSULATED.
TRUE
NORTH
PLAN
NORTH
1/8" = 1' - 0" 0 5' 10' 15' 30'
502F
INV.EL.: 504.50'
8"
4778.97 S.F.
134.19 GPM
BG
INV.EL.: 503.87'
6"
3505.71 S.F.
193.52 GPM
BG
S D
SD
SD
SD SD SD SD SD
S D
1 3 3.1 3.4 4 4.5 4.8 5 5.3 6 7.4E 6.5 9E 7 7.5 8 12E 12.2E 9 9.7 9.8 9.9 14E 10 10.5 11 15E 12 16E
K
I
H
G.5
G
F
C.4
C.2
C
B.5
B
A
RE
QE
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
FOUNDATION WASTE, DRAIN, AND VENT
PIPING PLAN - CLC ADMIN BID ALTERNATE 5
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL107
613-121
June 27, 2018 GTK DLB
1. 4"SD-UP.
2. 6"SD-UP.
3. 8"SD-UP.
4. 4"SD-UP TO FLOOR CLEANOUT.
5. REFER TO CIVIL FOR CONTINUATION OF PIPING.
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING CODE,
LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING DESIGN
GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING CHANGES
DIRECTIONS OVER 45 DEGREES.
B. 2" SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO PERCENT,
ONE-QUARTER INCH PER FOOT. 3" THRU 6" SEWER/WASTE PIPING SHALL
BE SLOPED A MINIMUM ONE PERCENT, ONE-EIGHTH INCH PER FOOT.
TRUE
NORTH
PLAN
NORTH
1/8" = 1'-0"
FOUNDATION PLAN - CLC ADMIN ALTERNATE NO. 5
1/8" = 1' - 0" 0 5' 10' 15' 30'
DNDN
DN
DN
1210.5
CORR.
501D-105
ELECTRICAL
501D-104
LOADING
501D-103
MECHANICAL
501D-102
IT
501D-101
ENTRANCE
501D-100
CORRIDOR
501D-C1
BUILDING 501
2AC
SD SD SD SD
SDSDSD SD
S D
OD OD OD OD
OD
OD OD OD
AC
AC
AC
AC
AC
AC
AC
AC
CONNECTOR
RAMP
501D-C5
CONNECTOR
RAMP
501D-C6
1 AC
AC
AC
AC
AC
S D
FCO
1 3 3.1 3.4 4 4.5 4.8 5 5.3 6 7.4E 6.5 9E 7 7.5 8 12E 12.2E 9 9.7 9.8 9.9 14E 10 10.5 11 15E 12 16E
K
I
H
G.5
G
F
C.4
C.2
C
B.5
B
A
RE
QE
th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
FIRST FLOOR PLUMBING PIPING PLAN - CLC
ADMIN BID ALTERNATE 5
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL108
613-121
June 27, 2018 GTK DLB
1. 3"SD-UP TO ROOF DRAIN.
2. 3"OD-UP TO EMERGENCY ROOF DRAIN.
3. 4"SD-UP TO ROOF DRAIN.
4. 4"OD-UP TO EMERGENCY ROOF DRAIN.
5. 6"SD-DN.
6. 8"SD-DN.
7. 6" DOWNSPOUT NOZZLE. MOUNT CENTERLINE AT 113" ABOVE FINISHED
GRADE.
8. 8" DOWNSPOUT NOZZLE. MOUNT CENTERLINE AT 113" ABOVE FINISHED
GRADE.
9. 4"SD-DN.
GENERAL NOTES
KEY NOTES
GRAPHIC SCALE(S)
1/8" = 1' - 0" 0 5' 10' 15' 30'
X
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING CODE,
LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING DESIGN
GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING CHANGES
DIRECTIONS OVER 45 DEGREES.
B. 2" SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO PERCENT,
ONE-QUARTER INCH PER FOOT. 3" THRU 6" SEWER/WASTE PIPING SHALL
BE SLOPED A MINIMUM ONE PERCENT, ONE-EIGHTH INCH PER FOOT.
C. ALL HORIZONTAL STORM DRAINAGE PIPING SHALL BE INSULATED.
TRUE
NORTH
PLAN
NORTH
1/8" = 1'-0"
FIRST FLOOR PIPING PLAN - CLC ADMIN ALTERNATE NO. 5
6"
6"
6"
4"
2"
2"
2"
2"
2"
2"
3"
2"
2"
P-103
P-401
P-103
P-401
P-502
FD-C P-103
P-401
P-103
P-401
P-609
P-528
P-528
P-528
P-528
P-528
P-528
P-609
P-524
2"
2"
4"
3"
3"
6"
8"
8"
6"
4"
8"
4"FCO
4"FCO
6"
4"FCO
4"
4"
4"
SD
OD
OD
OD
SD
SD
OD
OD
OD
OD
OD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
SD
S D
SAN
SAN
SAN
SAN
SAN
SAN
2"
SAN
SAN
SAN
2"
4"
4"
6" 4"
2"
4"
6" 2"
2" 2"
2"
3"
3"
3"
SAN
2" 4"
2" 4"
2" 4"
2"
4"
4"
4"
4"
4"
FCO
4"
2"
2"
2"
2"
2" 3"
2"
P-103
FD-E
P-528
P-401
P-103 P-528
P-528
P-609
P-103
P-401
P-528
P-528
P-528
P-528
P-502
P-528
2"
FD-C
P-401
2"
4"
4"
2"
2"
2"
2"
4"
6"
4"
2"
6"
6"
3"
FCO
FCO
4"
4"
4"
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SD
OD
OD
OD
OD
SD
S D
SD
SD
S D
SAN
SAN
2"
2"
3"
3"
2"2"
2"
4"
4"
WCO
FCO
2"
2"
2"
2"
4"
2" th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
WASTE, DRAIN, AND VENT PIPING ISOMETRIC
RISER DIAGRAMS
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL201
613-121
June 27, 2018 GTK DLB
NO SCALE
ISOMETRIC RISER DIAGRAM - WASTE, DRAIN, AND VENT PIPING
CLC ADMIN ISOMETRIC RISER DIAGRAM DOM CLINIC ISOMETRIC RISER DIAGRAM
501D & 502F
1. 3" VENT THRU ROOF.
2. 3" ROOF DRAIN.
3. 3" EMERGENCY ROOF DRAIN
4. 4" ROOF DRAIN.
5. 4" EMERGENCY ROOF DRAIN.
6. 4" RAIN WATER NOZZLE. MOUNT CENTERLINE AT 155" ABOVE FINISHED
GRADE.
7. 6" RAIN WATER NOZZLE. MOUNT CENTERLINE AT 113" ABOVE FINISHED
GRADE.
8. 8" RAIN WATER NOZZLE. MOUNT CENTERLINE AT 113" ABOVE FINISHED
GRADE.
GENERAL NOTES
KEY NOTES
A. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING
CODE, LOCAL CODES, VA PLUMBING DESIGN MANUAL, VA PLUMBING
DESIGN GUIDE AND/OR HORIZONTAL SANITARY SEWER/WASTE PIPING
CHANGES DIRECTIONS OVER 45 DEGREES.
B. 2" SANITARY SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. 3" THRU 6" SANITARY
SEWER/WASTE PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT, ONE-
EIGHTH INCH PER FOOT.
C. HORIZONTAL STORM DRAIN PIPING SHALL BE INSULATED.
3/4"
3/4"
3/4"
1"
1"
1 1/4"
2"
2"
2 1/2"
2 1/2"
2 1/2"
3/4"
2 1/2"
1 1/4"
1 1/2"
P-401
P-103 P-401
P-103
P-502
P-401 P-103 P-401
P-103
P-609
P-528
P-528
P-528
P-528
P-528
P-528
RP-1
P-609
RP-2
P-524
WH-1
WH-1
WH-2
WH-1
WH-1
WH-2
WH-2
WH-2
WH-2
3/4"
1 1/4"
3/4"
P-812
1/2"
2"
2"
T P
T P
2"
2"
2"
2"
2"
2"
1 1/2"
3/4"
2"
1 1/2"
P-103
P-401
P-528
P-528
P-528
P-528 P-609
P-103
P-401
P-528
P-528
P-528
P-528
P-502
P-401 P-103
WH-2
WH-2
WH-2
WH-2
WH-1WH-2
WH-2
WH-2
WH-2
WH-1
WH-1
WH-2
TP
T P
T P th re e in ch es o ne fo ot 6"
Department of Veterans Affairs on e an d on e ha lf in ch es o ne fo ot
6" on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ei gh th in ch o ne fo ot
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
DOMESTIC WATER DISTRIBUTION ISOMETRIC
RISER DIAGRAMS
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
PL301
613-121
June 27, 2018 GTK DLB
NO SCALE
DOMESTIC WATER DISTRIBUTION ISOMETRIC RISER DIAGRAMS
CLC ADMIN ISOMETRIC RISER DIAGRAM DOM CLINIC ISOMETRIC RISER DIAGRAM
501D & 501F
1. PROVIDE AND INSTALL NEW WATER HAMMER ARESTER. REFER TO
SCHEDULE ON DRAWOMG P001.
2. PROVIDE AND INSTALL BALANCING VALVE (CIRCUIT SETTER) ABOVE
CEILING AT APPROXIMATE LOCATION INDICATED. DOMESTIC WATER
CIRCULATION CIRCUITS SHALL BE TESTED, BALANCED, AND CERTIFIED BY
A COMPANY WHO SPECIALIZES IN SUCH SERVICES. A TEST AND BALANCE
REPORT SHALL BE PROVIDED INDICATING A MINIMUM OF 3 GPM FLOW OF
DOMESTIC COLD WATER.
3. PROVIDE AND INSTALL ANALOG THERMOMETER, TEMPERATURE SENSOR,
AND PETE'S PLUG ON DOMESTIC COLD WATER PIPING AT APPROXIMATE
LOCATION INDICATED. SENSORS SHALL BE CONNECTED TO BUILDING
CONTROLS SYSTEM. COORDINATE WITH THE CONTROLS CONTRACTOR.
4. PROVIDE AND INSTALL NEW TRAP PRIMER DEVICE AND ALL PIPING TO
FLOOR DRAIN.
5. PROVIDE AND INSTALL NEW 3/4" NON-FREEZE WALL HYDRANT (P-801).
MOUNT CENTER OF WALL HYDRANT AT 24" ABOVE FINISHED GRADE.
GENERAL NOTES
KEY NOTES
2 3
A. DOMESTIC COLD WATER SUPPLY AND DOMESTIC COLD WATER RETURN
PIPING SHALL BE INSULATED.
File details come from the government source that posted it.