36C24518B0233-003.pdf
PDF 18 MB Posted
- Attached to
- CONST DOM CLINIC & CLC ADMIN PROJ 613-121 Federal contract opportunity
- Solicitation number
- 36C24518B0233
About this file
36C24518B0233 1 Civil Drawings.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24518C0215-000.docx | DOCX document | |
| 36C24518B0233-0001001.pdf | ||
| 36C24518B0233-0001000.docx | DOCX document | |
| 36C24518B0233-010.pdf | ||
| 36C24518B0233-013.pdf | ||
| 36C24518B0233-009.pdf | ||
| 36C24518B0233-008.pdf | ||
| 36C24518B0233-007.pdf | ||
| 36C24518B0233-001.docx | DOCX document | |
| 36C24518B0233-002.pdf | ||
| 36C24518B0233-012.pdf | ||
| 36C24518B0233-011.pdf | ||
| 36C24518B0233-005.pdf | ||
| 36C24518B0233-004.pdf | ||
| 36C24518B0233-006.pdf | ||
| 36C24518B0233-000.docx | DOCX document |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
SITE SYMBOLS CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C001
613-121
JUNE 27, 2018
501D & 502F
LEGEND:
EXISTING:
CENTERLINE
OVERHEAD ELECTRIC LINE
UNDERGROUND ELECTRIC LINE
FENCE LINE
FIBER OPTIC LINE
GUARD RAIL
UNDERGROUND GAS LINE
SANITARY SEWER
TELECOMMUNICATIONS LINE
OVERHEAD WIRE
WATER LINE
CABLE TV LINE MARKER
CABLE TV PEDESTAL
TYPICAL CATCH BASINS
DRAINAGE CLEANOUT
DOWNSPOUT
STORM DRAIN END SECTION
TYPICAL INLETS
STORM DRAIN MANHOLE
ELECTRIC BOX
ELECTRICAL MANHOLE
ELECTRIC LINE MARKER
ELECTRIC METER
ELECTRIC TRANSFORMER
SANITARY SEWER FORCE MAIN BLOW OFF
SANITARY SEWER FORCE MAIN RELEASE
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE
SEPTIC TANK
FIBER OPTIC BOX
FIBER OPTIC MANHOLE
FIBER OPTIC LINE MARKER
GAS MANHOLE
GAS LINE MARKER
GAS METER
GAS REGULATOR
GAS VALVE
GAS VENT
GAS WELL
GAS WELL (ABANDONED)
TELECOMMUNICATIONS MANHOLE
TELECOMMUNICATIONS LINE MARKER
TELECOMMUNICATIONS PEDESTAL
UTILITY GUY POLE
UTILITY GUY WIRE
UTILITY POLE
EXISTING:
WATER LINE BLOW OFF
WATER FOUNTAIN
HOSE BIB
HYDRANT
WATER MANHOLE
WATER LINE MARKER
WATER METER
WATER LINE PLUG
WATER LINE REDUCER
WATER LINE AIR RELEASE VALVE
FIRE CONNECTION ("SIAMESE" /STORZ)
SPRINKLER CONTROL
SPRINKLER HEAD
WATER VALVE
WELL
GEOTHERMAL WELL
BBQ GRILL
BOLLARD
FLAGPOLE
FUEL PUMP
HANDICAP SYMBOL
HVAC UNIT
LIGHT POST
SINGLE FIXTURE OVERHEAD LIGHT POLE
DOUBLE FIXTURE OVERHEAD LIGHT POLE
PARKING
PERCOLATION TEST
RAILROAD BOX
RAILROAD SIGNAL
RAILROAD SWITCH
SATELITE DISH
SEEP
CONIFEROUS SHRUB
DECIDUOUS SHRUB
CONIFEROUS TREE
DECIDUOUS TREE
SINGLE POLE SIGN
DOUBLE POLE SIGN
TOE OF SLOPE
TRAFFIC BOX
TRAFFIC SIGNAL
MAILBOX
PROPOSED: PROPOSED:
UNDER GROUND DUCT BANK
UTILITY MANHOLE
UNDER GROUND GAS LINE
UNDER GROUND TELEPHONE
UNDER GROUND CABLE/TELEPHONE
UNDER GROUND STEAM
SECURITY CAMERA
CALLBOX
FIBER OPTIC
STORM DRAIN PIPE
SDC-MH1
RIM EL.=500.02
INV IN=495.15
SDC-DI1
RIM EL.=500.75
INV OUT=496.50
BENCHMARK
IRON PIPE & CAP
ELEV.=498.13
N-33784.4860
E-2417051.9010
BENCHMARK
CAPPED REBAR
ELEV.=506.31
N-338426.5217
E-2417005.7077 thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
EXISTING SITE FEATURES-
BUILDINGS 501 & 502
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C100
613-121
501 & 502
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
June 27, 2018
EXISTING CONDITIONS NOTES:
1. The original site survey was prepared by Triad Engineering Inc., dated March 16, 2017 .
2. Supplemental site survey field work was completed by Triad Engineering Inc. in July and August
2017. Existing conditions shown hereon reflect expanded survey area prepared by Triad
Engineering Inc., and last updated August 4, 2017.
3. Existing above-grade and below-grade utilities have been shown in accordance with the best available information. It shall be the Contractor's responsibility to verify exact locations of existing utilities prior to commencing Work. Notify the COR and the appropriate utility provider immediately should discrepancies be found in mapping of underground utilities be encountered during earthwork operations. Record all existing utility locations verified in the field.
4. Refer to Sheet C001 for Existing Conditions Survey Symbols and Abbreviations.
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
SITE DEMOLITION PLAN CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
CD100
613-121
501 & 502
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
June 27, 2018
DEMOLITION PLAN NOTES:
1. The exact location and depth of existing utilities must be field-verified by the
Contractor prior to construction of proposed improvements, including, but not limited to, the location of all buried electrical lines.
2. Refer to Sheet C001 for Site Symbols and Abbreviations.
3. Refer to Electrical Drawings for power utility demolition or relocation work and exterior site lighting demolition, Sheet EP101.
4. All trees to be removed shall be tagged in the field prior to the start of construction; no construction work of any kind shall take place until the COR confirms, in writing, that the proper trees have been tagged.
5. Plant material to remain shall be protected from injury to their roots, trunks, and branches; maintain protection during the entire construction period.
6. Install tree protection fencing beyond drip line of existing trees to remain; stake fencing securely in place with posts set at 10'-0” max. Erect fencing prior to commencing work.
7. No material shall be stored or piled with 25'-0” of the trunks of any tree.
8. No gasoline, fuel oil, harmful chemical or material shall be stored within 150' of any tree to be preserved.
9. No vehicles shall be permitted in the tree protection area.
10. Repair all injuries to bark, trunk, limbs, and roots of remaining plants by properly dressing, cutting, tracing and painting, using approved arboricultural practices.
11. The General Contractor shall replace any tree larger than 6” dbh that dies due to construction activities during the period from start of construction to eighteen (18) months after the issuance of the certificate of occupancy for the building.
12. Remove all existing traffic signage within limits of work; store and reinstall or remove from site as directed by Owner, unless noted otherwise. Provide new signage as indicated.
13. Approximate limits of tree protection fence are also indicated on the site plan. The final location of the tree protection fence shall be coordinated in the field and approved by the COR.
14. The exact location and depth of existing utilities must be field-verified by the contractor prior to construction of proposed improvements.
15. The contractor shall be responsible for locating/verifying all buried utilities.
16. Coordinate all saw cutting of pavement and pavement removal with the proposed work. See Sheet C110 for approximate limits of new pavement.
17. Mill existing pavement to provide key between new and existing pavements.
18. Deliver all salvaged items to the Owner, unless intended to be re-installed in kind. Coordinate staging and material storage areas with the COR, and with the Erosion and Sedimentation Control Plan, Sheet C150.
19. Clear and grub only as needed. Perform no work that will cause damage to existing trees and their root systems to remain. Note that tree root systems generally mirror the tree canopy in diameter.
20. Remove existing lawn and strip topsoil only as required to perform the work.
Coordinate any removal or stripping work under canopy of existing trees to remain with professional care.
21. Haul and properly dispose of all extra soil in accordance with the construction waste disposal notes on the erosion and sedimentation control plans.
22. Do not store topsoil beneath the drop line of existing trees to remain. If additional topsoil storage space is required, coordinate with the owner and with the local conservation district.
23. Contractor to salvage any miscellaneous sign faces within limits of work that may interfere with the proposed work and deliver to the Owner. Contractor to remove and dispose of any related posts and foundations.
DEMOLITION PLAN KEYNOTES:
1 LIMIT OF DEMOLITION PLAN UNDER BASE BID
2 EXISTING STORM SEWERS AND INLETS ARE TO BE
UNOBSTRUCTED AND FUNCTIONAL DURING CONSTRUCTION AND
REMAIN IN USE UNTIL INSTALLATION OF NEW STORM SEWERS AND
INLETS AS DEPICTED ON C140 IS COMPLETE
3 EXISTING TREE TO REMAIN - PROTECT ROOT ZONE
4 EXISTING TREE TO BE REMOVED
5 STRUCTURE TO BE REMOVED AND RECONSTRUCTED AS
DIRECTED BY C.O.R; SLAB AND FOOTINGS TO BE REMOVED.
6 STRUCTURE REMOVED - PLUG STORM DRAIN.
7 UNDERGROUND ELECTRIC CONDUIT AND VAULT TO REMAIN. LID
TO BE REMOVED AND REPLACED PER WALL SECTION 1, SHEET A354.
8 UNDERGROUND ELECTRIC JUNCTION BOX AND ASSOCIATED
CONDUITS TO BE REMOVED AND REPLACED. SEE ELECTRIC SHEET
ED101
9 RETAINING WALL SECTION TO BE REMOVED A MINIMUM OF 6"
BELOW THE FULL DEPTH SECTION OF PROPOSED CONCRETE SLAB
FOR THIS AREA
10 SAWCUT TO PROVIDE STRAIGHT EDGE
11 SHED TO BE REMOVED AND NOT REPLACED.
DEMOLITION PLAN LEGEND:
W
W
W
W
W
D u c t i l e
I r o n
P i p
L
F
D u c t i l e
I r o n
P i p e
L
D u c t i
L
PROP CONC
SIDEWALK
RETAINING WALL #2
18" ABOVE SIDEWALK
CONCRETE CURB
AND GUTTER
ASPHALT
RIP RAP
OUTLET
10 SEE SHEET 540
BUILDING 501D
FF ELEV 507.5
EXISTING
BUILDING 501C
MATCHLINE
THIS SHEET
RIP RAP
OUTLET
S
T
A
N
D
O
F
F
A
N
D
O
F
F
RETAINING WALL #1
ASPHALT
PAVEMENT
PATCH
RETAINING WALL #2
18" ABOVE SIDEWALK
REPLACE CONCRETE
CURB & GUTTER
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
MATCHLINE
THIS SHEET
ASPHALT
PAVEMENT
PATCH
REPLACE CONCRETE
CURB & GUTTER
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
SITE MATERIALS -
BUILDING 501D
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C110
613-121
501D
June 27, 2018
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
MATERIALS PLAN NOTES:
1.All site work, materials and construction, and construction methods shall comply with local municipality, Berkeley County, and the WV DOT material and construction specifications.
2.The Contractor shall restore any structure, pipe, utility, pavement, curbs, sidewalks, landscaped areas, etc. disturbed during construction to the original condition or better.
3.The exact location and depth of existing utilities must be field-verified by the Contractor prior to construction if the proposed improvements.
4.The contractor shall be responsible for locating/verifying all buried utilities.
5.All dimensions to curbs are to be taken to curb face.
6.Provide continuous expansion joint and sealant at interface of all concrete paving and curbs, building faces, and existing concrete or asphalt surfaces.
MATERIALS PLAN KEYNOTES:
1 LIMIT OF BITUMINOUS PAVEMENT
2 LIMIT OF PROPOSED SIDEWALK
3 LIMIT OF CURB AND GUTTER
4 CURB NOSE DOWN FOR HANDICAP RAMPS
5 PROPOSED RETAINING WALL (DETAIL SHEET C511, DETAIL 3 & 4)
6 PROPOSED HANDRAIL (ALONG ADA SIDEWALK)
7 4" WIDE PAINTED WHITE LINES (45" ANGLE AT 24" C-C)
8 "NO PARKING: LOADING/UNLOADING ZONE" SIGN
9 DUMPSTER PAD AREA (CONCRETE)
10 SWM STRUCTURE - MICRO BIO-RETENTION
11 EXISTING TREE TO REMAIN
12 CONCRETE GUTTER
13 BOLLARDS (4")
14 CONSTRUCTION FENCE
15 ADA RAMPS
16 BOLLARDS (6")
17 ELECTRIC LIFT GATES
MATERIALS PLAN LEGEND:
CONCRETE PAVEMENT
BITUMINOUS PAVEMENT
W
W
W
W
W
W
W
W
W
E
X
I
S
T
I
N
G
A
C
C
E
R
I
V
E
W
A
Y
P
R
O
P
O
S
E
D
E
W
A
L
K
P
R
O
P
O
S
D
E
W
A
L
K
X
D
E
W
A
L
K
PROPOSED
BUILDING 502F
FF 507.5
PROPOSED
CONCRETE PAD
E
X
I
S
T
I
T
E
R
L
I
N
E
TIE TO
EXISTING
TIE TO
EXISTING
PROP.
LIFT GATE
4 5
PROP.
LIFT GATE
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
SITE MATERIALS - BUILDING 502F CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C111
613-121
502F
JUNE 27, 2018
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
MATERIALS PLAN NOTES:
1.All site work, materials and construction, and construction methods shall comply with local municipality, Berkley County, and the WV DOT material and construction specifications.
2.The Contractor shall restore any structure, pipe, utility, pavement, curbs, sidewalks, landscaped areas, etc. disturbed during construction to the original condition or better.
3.The exact location and depth of existing utilities must be field-verified by the Contractor prior to construction if the proposed improvements.
4.The contractor shall be responsible for locating/verifying locations all buried utilities.
5.All dimensions to curbs are to be taken to curb face.
6.Provide continuous expansion joint and sealant at interface of all concrete paving and curbs, building faces, and existing concrete or asphalt surfaces.
MATERIALS PLAN LEGEND:
MATERIALS PLAN KEYNOTES:
1 CONSTRUCTION FENCE(AT DISCRETION OF THE COR)
2 LIMIT OF PROPOSED SIDEWALK
3 EXISTING TREE TO REMAIN
4 ADA RAMP
5 CURB NOSE DOWN
6 ELECTRIC LIFT GATES
CONCRETE PAVEMENT
O
N
C
S
I D
E
W
A
L K
PROPOSED
BUILDING 501D
MATCH GUTTER TO
EXISTING CONCRETE
SLAB WITH NOSE
DOWN CURB
MATCH EXISTING
CURB AND GUTTER
EX. ELECTRIC GATE
CONCRETE BASE
EX. LIGHT POLE BASE
A
N
D
O
F
F
A
N
D
O
F
F
PROPOSED
ELECTRIC GATE
A
N
D
O
F
F
NEW RETAINING
WALL SECTION -
SEE STRUCTURAL
SHEET
CONTRACTOR TO
SAWCUT AND REMOVE
EX CONCRETE LARGE
ENOUGH TO PERFORM
NECESSARY WORK
PROPOSED
RETAINING WALL 1
PROPOSED
RETAINING WALL 2
PROPOSED
ELECTRIC GATE
BID DOCUMENTS
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
SITE STAKE OUT PLAN -
BUILDING 501D
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C120
613-121
501D
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
June 27, 2018
N
C
S
I
D
E
W
A
L
K
P
R
N
C
S
I
D
E
W
A
L
K
P
R
N
C
S
I
D
E
W
A
L
K
P
R
N
C
S
I
D
E
W
A
L
K
EX. CONCRETE
REMOVE AND
REPLACE
A
N
D
O
F
F
A
N
D
O
F
F
A
N
D
O
F
F
BID DOCUMENTS
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
SITE STAKE OUT PLAN -
BUILDING 502F
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C121
613-121
502F
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
P
R
N
C
R
E
T
E
S
I
D
E
W
A
L
K
D
A
PROPOSED STORM
MANHOLE, CONNECT
TO EX STORM DRAIN
(DOGHOUSE)
PROPOSED SWM
OUTLET STRUCTURE
GRATE ELEV.= 500.75
PROP CURB
CUT INLET
TOP ELEV= 503.70
PROP CURB
CUT INLET
TOP ELEV.= 503.00
PROPOSED SWM
MICRO-BIORETENTION
BUILDING 501D
F.F. ELEV.=507.5
ASPHALT PAVING
TIE INTO EXISTING
CURB AND GUTTER
TIE INTO EXISTING
CURB AND GUTTER
MATCH GUTTER TO
EXISTING CONCRETE
SLAB WITH NOSE
DOWN CURB
PROPOSED STORM MANHOLE
SDMH-A1
RIM ELEV.=507.25
PROP SSMH
RIM ELEV.= 502.63
PROP SSMH
RIM ELEV.=499.92
MATCH EXISTING
CURB AND GUTTER
EX. ELECTRIC GATE
CONCRETE BASE
LIGHT POLE BASE
PROP SSMH
RIM ELEV.= 506.35
PROP. END SECTION
OUTLET= 500.25
PROP ELECTRIC
LIFT GATE
A
N
D
O
F
F
A
N
D
O
F
F
NYLOPLAST STRUCTURE
RIM ELEV.=507.15
M
A
T
H
E
X
I
S
T
I
N
C
R
E
T
E
FF ELEV
- 507.50 x
507.18
B
T
W
507.25 x508.68
TW
507.50 x 507.33 x 506.67 x 506.25 x 505.88
506.67
FF ELEV
- 507.50 x 507.45 x 507.45
507.45 BC
507.95 TC
x 507.00 BC
507.50 TC
x 506.85 BC
507.35 TC
x 507.45 BC
507.95 TC
504.72 BC
505.22 TC
506.22 TW
507.00 BC
507.50 TC
508.50 TW
508.20 TW
506.70 BW
x
508.60 TW
507.10 BW
x x x x 506.67 x 506.67 x 507.00 x 511.50 x 511.0 x 510.00 x 507.00 x 509.25 x 509.85 TW x 507.75 BW x 510.00 x 511.00 x 511.50 x 507.45 x 507.40 x 507.75 BW x 507.75 BW x 507.40
506.50 x x 507.00 x 509.50
508.25 x 506.50 x 503.09 B C
503.59 TC
502.61 B
C x
502.73 TC
502.45 B
C x
502.57 TC
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
SITE GRADING PLAN -
BUILDING 501D
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C130
613-121
June 27, 2018
501D
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
1. All grades are to be taken as being direct between any two elevations shown, unless indicated otherwise.
2. Contours shall be used as grade points where no spot elevations are shown.
3. Identify and clearly mark benchmarks. Verify and record benchmark elevations prior to commencing work. Protect benchmarks and survey control points from damage or displacement. Reestablish or relocate benchmarks disturbed by site work operations at the Contractor's expense.
4. “Benchmark” - See Sheet C100. All elevations shown are based on benchmark.
5. Existing above-grade and below-grade utilities have been shown in accordance with the best available information. It shall be the Contractor's responsibility to verify exact locations of all existing utilities prior to commencing work. Notify the COR and the appropriate utility provider immediately should discrepancies be found in mapping of underground utilities be encountered during earthwork operations. Record all existing utility locations verified in the field.
6. Refer to Sheet C510 for Erosion and Sedimentation Control Plan and permitted Limit of Disturbance.
7. The Contractor shall strip topsoil from all areas to be regraded and/or disturbed. Coordinate limits of disturbance and topsoil stockpile locations with all other prime contractors.
8. Verify suitability of subsoil materials. All fill materials are subject to testing and inspection.
9. Provide positive drainage away from all buildings and structures. Avoid the development of isolated low spots to prevent freestanding surface water.
10.All walks shall have a cross pitch of 2% in the direction of the slope or to the curb.
11.High and low points on walks and curbs shall be rounded off to a distance of at least five feet to show no abrupt change of grade.
12.The tops and bottoms of all slopes shall be rounded off to smooth curves five feet long.
13.Make new grade changes gradual; blend slope into level areas. Provide smooth transitions between new and existing grades.
14.Finish grade behind curb shall be flush with the top of the curb, unless otherwise noted.
15.Where mulched planting areas abut curb, finish soil grade behind curb shall be maintained three-inches below top of curb to allow for placement of mulch.
16.Remove stockpile areas, leave area in clean and neat condition; grade site surface to meet the proposed grades and to prevent freestanding surface water.
17.The Contractor shall preserve existing vegetation where possible and/or as noted on the drawings.
18.The Contractor is responsible for the removal and disposal of all rubbish, trash, debris and organic material in a lawful manner.
19.Verify required spot elevations/grading in the vicinity of the building with the architectural plans.
20. Where new construction abuts existing improvements, verify the elevations and grades of the existing improvements. Notify the Architect of discrepancies between the survey and existing field conditions prior to proceeding with new work.
21. Where utility trenching occurs, restore finished grades to match existing conditions unless otherwise indicated.
22. See lighting plan for locations of proposed site lighting and related electric utility service.
23. If a sinkhole is encountered during construction, contact a Geotechnical Engineer licensed in the State of West Virginia for a Repair Plan.
GRADING PLAN NOTES: GRADING PLAN LEGEND:
x 488.80
Major Contour
Minor Contour
Spot Elevation
Limit of Disturbance
Contour Elevation
Designation
Existing Contour
PROPOSED 24"
NYLOPLAST YARD
INLET, CONNECT TO
EX STORM DRAIN
TOP ELEV = 505.85
PROPOSED 12"
NYLOPLAST
YARD INLET
GRATE EL.=507.28
12" NYLOPLAST
YARD INLET
TOP = 506.73
P
R
N
C
S
I
D
E
W
A
L
K
P
R
N
C
S
I
D
E
W
A
L
K
P
R
N
C
S
I
D
E
W
A
L
K x 506.90 x 506.00 x 506.12 x 506.80 x 506.85 x 506.70 x 506.60 x 506.75 x 507.40 x 507.40 x 507.40 x 507.40 x 507.40 x 507.40 x 507.35 x 507.35 x 507.35 x 507.35 x 507.35 x 507.25 x 506.75 x 507.40 x 507.40 x 507.10 x 507.20 x 507.00
507.00 x 507.40 x 507.40 x 507.20 x 505.95 x 506.75 x 506.68 x 507.40
507.10 x
507.20 x x 507.40 x 507.40 x x
MATCH EXISTING GRADE
APPROX 506.10
MATCH EXISTING GRADE
APPROX 506.15
T
A
N
D
O
F
F
A
N
D
O
F
F
PROPOSED 12"
NYLOPLAST
YARD INLET
GRATE EL.=507.15
PROPOSED 12"
NYLOPLAST
YARD INLET
GRATE EL.=506.85
PROPOSED 12"
NYLOPLAST
YARD INLET
GRATE EL.=506.55
PROPOSED 12"
NYLOPLAST
YARD INLET
GRATE EL.=507.00
BID DOCUMENTS
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
SITE GRADING PLAN - BUILDING 502F CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C131
613-121
502F
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
June 27, 2018
1. All grades are to be taken as being direct between any two elevations shown, unless indicated otherwise.
2. Contours shall be used as grade points where no spot elevations are shown.
3. Identify and clearly mark benchmarks. Verify and record benchmark elevations prior to commencing work. Protect benchmarks and survey control points from damage or displacement. Reestablish or relocate benchmarks disturbed by site work operations at the Contractor's expense.
4. “Benchmark” - See Sheet C100. All elevations shown are based on benchmark.
5. Existing above-grade and below-grade utilities have been shown in accordance with the best available information. It shall be the Contractor's responsibility to verify exact locations of all existing utilities prior to commencing work. Notify the COR and the appropriate utility provider immediately should discrepancies be found in mapping of underground utilities be encountered during earthwork operations. Record all existing utility locations verified in the field.
6. Refer to Sheet C510 for Erosion and Sedimentation Control Plan and permitted Limit of Disturbance.
7. The Contractor shall strip topsoil from all areas to be regraded and/or disturbed. Coordinate limits of disturbance and topsoil stockpile locations with all other prime contractors.
8. Verify suitability of subsoil materials. All fill materials are subject to testing and inspection.
9. Provide positive drainage away from all buildings and structures. Avoid the development of isolated low spots to prevent freestanding surface water.
10.All walks shall have a cross pitch of 1/4 inch per foot in the direction of the slope or to the curb.
11.High and low points on walks and curbs shall be rounded off to a distance of at least five feet to show no abrupt change of grade.
12.The tops and bottoms of all slopes shall be rounded off to smooth curves five feet long.
13.Make new grade changes gradual; blend slope into level areas. Provide smooth transitions between new and existing grades.
14.Finish grade behind curb shall be flush with the top of the curb, unless otherwise noted.
15.Where mulched planting areas abut curb, finish soil grade behind curb shall be maintained three-inches below top of curb to allow for placement of mulch.
16.Remove stockpile areas, leave area in clean and neat condition; grade site surface to meet the proposed grades and to prevent freestanding surface water.
17.The Contractor shall preserve existing vegetation where possible and/or as noted on the drawings.
18.The Contractor is responsible for the removal and disposal of all rubbish, trash, debris and organic material in a lawful manner.
19.Verify required spot elevations/grading in the vicinity of the building with the architectural plans.
20. Where new construction abuts existing improvements, verify the elevations and grades of the existing improvements. Notify the Architect of discrepancies between the survey and existing field conditions prior to proceeding with new work.
21. Where utility trenching occurs, restore finished grades to match existing conditions unless otherwise indicated.
22. See lighting plan for locations of proposed site lighting and related electric utility service.
23. If a sinkhole is encountered during construction, contact a Geotechnical Engineer licensed in the State of West Virginia for a Repair Plan.
GRADING PLAN NOTES:
GRADING PLAN LEGEND:
x 488.80
Major Contour
Minor Contour
Spot Elevation
Limit of Disturbance
Contour Elevation
Designation
Existing Contour
W
W
W
W
W
W
CONNECT TO EX
STORM DRAIN
WVDOH TYPE
"D" INLET
PROPOSED SWM
MICRO-BIORETENTION
PROP SPECIAL CUT
18" HDPE ELBOW (65°)
WVDOH TYPE
"B " INLET
WVDOH TYPE
"A" MANHOLE
PROP METAL
END SECTION
WVDOH TYPE
"D" INLET
M
A
T
S
G
E
" U
N D
E R
D R
A
IN 4
U
D
A
I
N
SDMH-A1
RIM EL.=507.25
INV IN=501.00
INV IN=503.00
INV OUT=496.16
SS-102
RIM EL.=507.25
INV OUT=496.00
SS-101
RIM EL.=502.63
INV IN=495.12
INV OUT=495.00
SS-100
RIM EL.=499.92
INV IN=494.24
INV OUT=494.14
D u c t i l e
I r o n
P i p e
L u c t i
L
P
R
D
T
E
R
L I
F
P
I P
E
H
D P
E
P i p e
UGE HANDHOLE
AND CONDUITS TO BE
RELOCATED OUTSIDE
OF THE BUILDING
FOOTPRINT.
SEE ELECTRICAL
DRAWINGS SHEET ED101
6" TAPPING
SLEEVE AND
VALVE
SDB-ES
INV IN=500.25
SDB-CI1
RIM EL.=503.29
INV IN=500.50
INV OUT=500.44
SDB-CI2
RIM EL.=503.51
INV OUT=500.66
S
T
O
M
A
T
O R
M
D
R A
T
O
A
UNDERGROUND FUEL
TANK AND MONITORING
WELLS TO NOT BE
DISTURBED.
A
N
D
O
F
F
SDC-DI1
RIM EL.=500.75
INV OUT=496.50
SDC-MH1
RIM EL.=500.02
INV IN=495.15
S D
C P
N
H
D P
E
S
D
B
P
E
S
D
B
P
E
S
D
A
P
I
P
P
E
SDE-DI1
RIM EL.=507.15
INV OUT=504.00
SDE-PIPE 2 8" N12 HDPE
18 LF @ 4.88%
SDE-PIPE 1 8" N12 HDPE
22 LF @ 4.03%
SDE-DI2
RIM EL.=509.25
INV OUT=502.00
SDF-DI1
RIM EL.=506.50
INV OUT=501.35
M
A
T
S
G
E
EXISTING SSMH
RIM EL.=498.17
INV IN=492.61
8" DIP
118 LF @ 1.26%
BID DOCUMENTS
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
SITE UTILITY PLAN - BUILDING 501D CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C140
613-121
501D
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
June 27, 2018
UTILITY PLAN NOTES:
1. The contractor shall be responsible for locating/verifying all buried utilities.
2. Refer to Sheet C150 for Erosion and Sedimentation Control Plan and permitted Limit of Disturbance.
3. The exact location and depth of existing utilities must be field-verified by the Contractor prior to construction of proposed improvements, including, but not limited to, the location of all buried electrical lines.
4. Final utility service point locations shall be verified and coordinated with Architectural drawings.
5. See Electrical drawings for additional electric, telephone and cable information.
6. Site Contractor shall coordinate site utility installation with electrical and telecommunication services.
7. Minimum cover shall be 36” deep on electric conduits and 24” on telephone and cable conduit. Install hand holes as required.
8. All water mains, water services and sanitary sewer laterals shall conform to the Department of Environmental Protection and appropriate utility company specifications.
9. Storm and sanitary sewer pipes shall be laid on straight alignments and even grades using a pipe laser or other accurate method.
10. Site Contractor shall provide all bends, fittings, adapters, etc. as required for pipe connections.
11. All valve lids, manholes, inlet tops, etc. affected or set by the construction shall be adjusted to finish grade elevation.
12. If the utilities aren't handled by a single prime Contractor, the site Contractor shall be responsible for all utilities to within 5' of the building or as shown on the plumbing drawingns and make the utility connections with the building contractor(s).
13. Site Contractor shall connect building downsprouts to roof drain header system shown on the plans.
14. Minimum separation between utilities shall be no less than (1) foot vertically. Notify Engineer if utility crossings cannot meet the minimum clearance requirements.
15. Contractor to connect foundation drains as shown on the plans.
UTILITY PLAN KEYNOTES:
1 CONNECT TO EXISTING UTILITY
2 TIE ROOF DAINS INTO STORM DRAIN SYSTEM (MIN. SLOPE 1/4 “ PER FOOT)
3 CONNECT 6” FOUNDATION DRAIN INTO STORM DRAIN SYSTEM
UTILITY PLAN LEGEND:
INSET
SCALE 1" = 10'
UNDERGROUND ELECTRIC LINE
SANITARY SEWER
TYPICAL CATCH BASINS
DRAINAGE CLEANOUT
STORM DRAIN END SECTION
TYPICAL INLETS
STORM DRAIN MANHOLE
SANITARY SEWER MANHOLE
WATER VALVE
WELL
STORM DRAIN PIPE
NYLOPLAST INLET
WATER LINE
W
W
W
W
W
W
W
V
L
S
T
O
A
TIE EXISTING ROOF
DRAINS INTO PROPOSED
8" COLLECTOR PIPE
P
R
N
C
S
I
D
E
W
A
L
K
P
R
N
C
S
I
D
E
W
A
L
K
P
R
N
C
S
I
D
E
W
A
L
K
PROPOSED BUILDING
502F
F.F. 507.5
24" NYLOPLAST INLET
TIE INTO EX STORM DRAIN
12" NYLOPLAST INLET
12" NYLOPLAST INLET
12" NYLOPLAST INLET
12" NYLOPLAST INLET
EX DOM
BUILDING 502D
EX DOM
BUILDING 502E
SDD-P1 8" N12 HDPE
27 LF @ 0.50%
SDD-P2 8" N12 HDPE
27 LF @ 0.50%
SDD-P3 8" N12 HDPE
29 LF @ 2.07%
S
D
D
N
P
E
S
D
D
P
E
SDD-P7 8" N12 HDPE
97 LF @ 0.91%
S
D
D
P
E
T
N
E
S
T
O
A
S
T
O
A
SDD-DI7
RIM EL.=506.66
INV OUT=503.32
12" NYLOPLAST INLET
EX. SSMH 24
RIM ELEV= 506.51
INV. OUT= 501.30
L
EX. SSMH 23
INV. IN= 500.60
EXCAVATE TO
PIPE AND
ENCASE IN
CONCRETE
EXCAVATE TO
PIPE AND
ENCASE IN
CONCRETE
12" NYLOPLAST INLET
SDD-DI6
RIM EL.=507.10
INV IN=503.26
INV OUT=503.16
SDD-DI3
RIM EL.=507.26
INV OUT=503.67
SDD-DI1
RIM EL.=505.85
INV IN=501.60
INV IN=501.60
INV OUT=501.50
SDD-DI2
RIM EL.=506.55
INV IN=502.00
INV OUT=501.88
SDD-DI4
RIM EL.=506.73
INV IN=502.10
INV OUT=502.00
SDD-DI5
RIM EL.=507.28
INV IN=503.10
INV OUT=503.00
8" N12 HDPE 13L.F. @ 0.5%
8" N12 HDPE 7L.F. @ 0.5%
PROP WET TAP
INTO EX. 8" DIP
WATERLINE
PROP 45°
VERTICAL BEND
PROP WET TAP
INTO EX.
WATERLINE
APPROX. LOCATION OF
UNDER GROUND
ELECTRICAL DUCT BANKS.
SEE ELECTRICAL PLAN
SHEET ED101
APPROX. LOCATION OF
UNDER GROUND TELE-COM
DUCT BANKS. SEE
ELECTRICAL PLAN SHEET
ED101
PROP
INSERTA-VALVE
AND END CAP
PROP
INSERTA-VALVE
AND END CAP
45°
45°
45°
45°
45°
45°
I
P
S
A
N
I
T
A
R
Y
S
E
W
N
E
A
Z
N
E
PROP 45°
VERTICAL BEND
A
I
N
A
I
N
SDD-CO3
SDD-CO2
SDD-CO1
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
SITE UTILITY PLAN-BUILDING 502F CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C141
613-121
502F
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
June 27, 2018
UTILITY PLAN NOTES:
1. In accordance with chapter 24-C underground facility damage prevention act, as amended, the Contractor must call the following phone number and notify all affected utility companies of the intention to excavate no less than 48 hours prior to excavation activities West Virginia 811, INC (WV 811) one call center: 1-800-245-4848 or 8911.
2. Refer to Sheet C150 for Erosion and Sedimentation Control Plan and permitted Limit of Disturbance.
3. The exact location and depth of existing utilities must be field-verified by the Contractor prior to construction of proposed improvements, including, but not limited to, the location of all buried electrical lines.
4. Final utility service point locations shall be verified and coordinated with Architectural drawings.
5. See Electrical drawings for additional electric, telephone and cable information.
6. Site Contractor shall coordinate site utility installation with electrical and telecommunication services.
7. Minimum cover shall be 36” deep on electric conduits and 24” on telephone and cable conduit. Install hand holes as required.
8. All water mains, water services and sanitary sewer laterals shall conform to the Department of Environmental Protection and appropriate utility company specifications.
9. Storm and sanitary sewer pipes shall be laid on straight alignments and even grades using a pipe laser or other accurate method.
10. Site Contractor shall provide all bends, fittings, adapters, etc. as required for pipe connections.
11. All valve lids, manholes, inlet tops, etc. affected or set by the construction shall be adjusted to finish grade elevation.
12. If the utilities aren't handled by a single prime Contractor, the site Contractor shall be responsible for all utilities to within 5' of the building or as shown on the plumbing drawingns and make the utility connections with the building contractor(s).
13. Site Contractor shall connect building downsprouts to roof drain header system shown on the plans.
14. Minimum separation between utilities shall be no less than (1) foot vertically. Notify Engineer if utility crossings cannot meet the minimum clearance requirements.
15. Contractor to connect foundation drains as shown on the plans.
UTILITY PLAN KEYNOTES:
1 CONNECT TO EXISTING UTILITY
2 TIE DOWNSPOUTS INTO STORM DRAIN SYSTEM (MIN. SLOPE 1/4 “ PER FOOT)
3 CONNECT 6” FOUNDATION DRAIN INTO STROM DRAIN SYSTEM
UTILITY PLAN LEGEND:
UNDERGROUND ELECTRIC LINE
SANITARY SEWER
TYPICAL CATCH BASINS
DRAINAGE CLEANOUT
STORM DRAIN END SECTION
TYPICAL INLETS
STORM DRAIN MANHOLE
SANITARY SEWER MANHOLE
WATER VALVE
WELL
STORM DRAIN PIPE
NYOPLAST INLET
W
W
W
W
W
W
CE
IP2
IP2
IP2
IP
IP
RR
RR
thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
EROSION & SEDIMENTATION CONTROL
(E&S) PLAN - BUILDING 501D
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C150
613-121
501D
KEYTITLE SYMBOL
STORM DRAIN
INLET PROTECTION
IP
IP2
(GRAVEL/WIRE MESH)
STORM DRAIN
INLET PROTECTION
(SILT FENCE)
PS
CONTROL LEGEND
KEY
CE
PERMANENT SEEDING
TEMPORARY STONE
CONSTRUCTION
ENTRANCE
TITLE
PS
SYMBOL
EROSION & SEDIMENT
TSTEMPORARY SEEDING
TS
SILT FENCE
SF
SF
June 27, 2018
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
CLEAN FILL AND ENVIRONMENTAL DUE-DILIGENCE
This erosion and sedimentation pollution control plan covers the “moving, depositing, stockpiling, or storing of soil rock or earth materials”. If this project will need fill imported from an off site location, the responsibility for performing environmental due diligence and the determination of clean fill will reside with the Contractor. Environmental due diligence is defined as investigative techniques, including, but not limited to visual property inspections, electronic data base searches, review of property ownership, review of property use history, Sanborn maps, environmental questionnaires, transaction screens, analytical testing, environmental assessments or audits. Analytical testing is not a required part of due diligence unless visual inspection and/or review of the past land use of the property indicates that the fill may have been subjected to a spill or release of regulated substance. If the fill may have been affected by a spill or release of a regulated substance, it must be tested to determine if it qualifies as clean fill. Testing should be performed in accordance with WV DEP's standards. Clean fill is defined as uncontaminated, non-water soluble, non-decomposable, inter, solid material. The term includes soil, rock, stone, dredged material, used asphalt, use brick, block or concrete from construction and demolition activities that is separate from other waste and is recognizable as such. The term does not include materials placed in or on the Waters of the State unless otherwise authorized. (The term “used asphalt” does not include milled asphalt or asphalt that has been processed for re-use.) Fill material that does not qualify as clean fill will be considered regulated fill. Regulated fill is waste and must be managed in accordance with the department's Solid Waste Program. If applicable, fill determination is not required by the contractor unless there is evidence that a spill or release of a regulated substance has occurred.
CONSTRUCTION WASTE DISPOSAL
Individual responsible for earth disturbance activities must ensure that proper mechanisms are in place to control waste materials. Construction wastes include, but are not limited to, excess soil materials, building materials, concrete wash water, sanitary wastes, etc. that could adversely impact water quality. Measures should be planned and implemented for housekeeping material management, and litter control. Bulk construction waste must be disposed of off-site, at a permitted location (I.E. Landfill). Excess fill material must be disposed of in an area that has an approved E&S Plan associated with
it. Concrete wash water and sanitary wastes may not be discharged to a storm sewer or permitted to flow overland to receiving waters. Wherever possible, recycling of excess materials is preferred, over disposal.
EROSION & SEDIMENT CONTROL NOTES:
1. In accordance with chapter 24-C underground facility damage prevention act, as amended, the Contractor must call the following phone number and notify all affected utility companies of the intention to excavate no less than 48 hours prior to excavation activities West Virginia 811, INC (WV 811) one call center: 1-800-245-4848 or 8911.
2. The exact location and depth of existing utilities must be field-verified by the contractor prior to construction of proposed improvements.
3. Provide transition from 6” curb height to flush condition in a 6'-0” horizontal length.
4. See lighting plan for locations of proposed site lighting and related electric utility service.
5. See Sheet C550 for additional notes and details.'
6. If a sinkhole is encountered during construction, contact a Geotechnical Engineer licensed in the State of West Virginia for a Repair Plan.
NPDES PERMIT:
The contractor is responsible for obtaining a General WV/NPDES Water Pollution Control Permit for stormwater associated with construction activities prior to commencing any earth disturbances.
TEMPORARY AND PERMANENT STABILIZATION SPECIFICATIONS
Temporary Seeding Permanent Seeding - Lawn Areas
Species: Annual Ryegrass Species: Kentucky 31
% Pure Live Speed: 98% Creeping Red Fescue
Application Rate: 25 LB/Acre Kentucky Bluegrass Mix
Fertilizer Type: 10-10-10 White Dutch Clover
Fertilizer Application Rate: 500 LB/Acre % Pure Live Speed: 98%, 98% 98%
Limiting Rate: 1 T./Acre Application Rate: 45-20-25-5 LB./Acre
Mulch Type: Hay Fertilizer Type: 10-20-10
Mulching Rate: 3 T./Acre Fertilizer Application Rate: 1000 LB/Acre
Liming Rate: Approx. 2 T./Acre OR To Achieve 6.5 pH Mulch Type: Clean Wheat or Oat Straw
Mulching Rate: 2 T./Acre
Anchor Material: None
Anchoring Method: None
Rate of Anchor Material Application: None
Seeding Season Dates: April 1 to May 30 or
Sept. 1 to Oct. 1
SOIL NAME AND
MAP SYMBOL
SOIL LIMITATIONS
ROADS
AND
STREETS
SHALLOW
EXCAVATIONS
LAWNS
AND
LANDSCAPING
COMMERCIAL
BUILDINGS
RECOMMENDATIONS
UkC
Urban land-Berks complex, 0 to 15 percent slopes
SwA
SWANDPOND SILT LOAM
0 TO 3 PERCENT SLOPES
Ub
URBAN LAND
SOIL NOT
RATED
VERY LIMITED:
SHRINK-SELL;
LOW STRENGTH;
FROST ACTION
SOIL NOT
RATED
SOIL NOT
RATED
NOT LIMITED
VERY LIMITED:
SHRINK-SWELL
EXERCISE CAUTION WHENEXCAVATING AND
ENSURE THAT FOUNDATIONS ARE BELOW FROST
LINES. MAINTAIN E&S AT ALL TIMES; CONTRACTOR
IS TO NOTIFY ENGINEER OF LIMITATIONS ARE
DISCOVERED DURING CONSTRUCTION
SOIL NOT
RATED
VERY LIMITED: TOO CLAYEY; DEPTH
TO SATURATED ZONE; UNSTABLE
EXCAVATION WALLS
SOIL NOT
RATED
SOIL NOT
RATED
SOIL NOT
RATED
SOIL NOT
RATED
MAINTAIN E&S AT ALL TIMES; CONTRACTOR IS TO
NOTIFY ENGINEER OF LIMITATIONS ARE
DISCOVERED DURING CONSTRUCTION
SOURCE: WEB SOIL USDA / NRCS WEB SOIL SURVEY ONLINE: HTTP://WEBSOILSURVEY.SC.EGOV.USDA.GOV
MAINTAIN E&S AT ALL TIMES; CONTRACTOR IS TO
NOTIFY ENGINEER OF LIMITATIONS ARE
DISCOVERED DURING CONSTRUCTION
RR
RIP RAP
OUTLET
PROTECTION
PS
PS
PS
W
W
W
W
W
W
W
L thr ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
VA FORM 08-6231
Revisions:
1 2 3 4 5 6 7 8 9
Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
590 MEANS ST NW ATLANTA, GA 30318
Drawing Title:
Approved Project Director:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number:
Building Number:
Project Number:
Dwg. of
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
BID DOCUMENTS
EROSION & SEDIMENTATION CONTROL
(E&S) PLAN - BUILDING 502F
CONSTRUCT DOM CLINIC
AND CLC ADMINISTRATION
ADDITION
MARTINSBURG, WV
C151
613-121
502F
KEYTITLE SYMBOL
STORM DRAIN
INLET PROTECTION
IP
IP2
(GRAVEL/WIRE MESH)
STORM DRAIN
INLET PROTECTION
(SILT FENCE)
PS
CONTROL LEGEND
KEY
CE
PERMANENT SEEDING
TEMPORARY STONE
CONSTRUCTION
ENTRANCE
TITLE
PS
SYMBOL
EROSION & SEDIMENT
TSTEMPORARY SEEDING
TS
SILT FENCE
SF
SF
IP2
IP2
CE
June 27, 2018
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
CLEAN FILL AND ENVIRONMENTAL DUE-DILIGENCE
This erosion and sedimentation pollution control plan covers the “moving, depositing, stockpiling, or storing of soil rock or earth materials”. If this project will need fill imported from an off site location, the responsibility for performing environmental due diligence and the determination of clean fill will reside with the Contractor. Environmental due diligence is defined as investigative techniques, including, but not limited to visual property inspections, electronic data base searches, review of property ownership, review of property use history, Sanborn maps, environmental questionnaires, transaction screens, analytical testing, environmental assessments or audits. Analytical testing is not a required part of due diligence unless visual inspection and/or review of the past land use of the property indicates that the fill may have been subjected to a spill or release of regulated substance. If the fill may have been affected by a spill or release of a regulated substance, it must be tested to determine if it qualifies as clean fill. Testing should be performed in accordance with WV DEP's standards. Clean fill is defined as uncontaminated, non-water soluble, non-decomposable, inter, solid material. The term includes soil, rock, stone, dredged material, used asphalt, use brick, block or concrete from construction and demolition activities that is separate from other waste and is recognizable as such. The term does not include materials placed in or on the Waters of the State unless otherwise authorized. (The term “used asphalt” does not include milled asphalt or asphalt that has been processed for re-use.) Fill material that does not qualify as clean fill will be considered regulated fill. Regulated fill is waste and must be managed in accordance with the department's Solid Waste Program. If applicable, fill determination is not required by the contractor unless there is evidence that a spill or release of a regulated substance has occurred.
CONSTRUCTION WASTE DISPOSAL
Individual responsible for earth disturbance activities must ensure that proper mechanisms are in place to control waste materials.
Construction wastes include, but are not limited to, excess soil materials, building materials, concrete wash water, sanitary wastes, etc.
that could adversely impact water quality. Measures should be planned and implemented for housekeeping material management, and litter control. Bulk construction waste must be disposed of off-site, at a permitted location (I.E. Landfill). Excess fill material must be disposed of in an area that has an approved E&S Plan associated with it. Concrete wash water and sanitary wastes may not be discharged to a storm sewer or permitted to flow overland to receiving waters. Wherever possible, recycling of excess materials is preferred, over disposal.
EROSION & SEDIMENT CONTROL NOTES:
1. In accordance with chapter 24-C underground facility damage prevention act, as amended, the Contractor must call the following phone number and notify all affected utility companies of the intention to excavate no less than 48 hours prior to excavation activities West Virginia 811, INC (WV 811) one call center: 1-800-245-4848 or 8911.
2. The exact location and depth of existing utilities must be field-verified by the contractor prior to construction of proposed improvements.
3. Provide transition from 6” curb height to flush condition in a 6'-0” horizontal length.
4. See lighting plan for locations of proposed site lighting and related electric utility service.
5. See Sheet C550 for additional notes and details.'
6. If a sinkhole is encountered during construction, contact a Geotechnical Engineer licensed in the State of West Virginia for a Repair Plan.
NPDES PERMIT:
The contractor is responsible for obtaining a General WV/NPDES Water Pollution Control Permit for stormwater associated with construction activities prior to commencing any earth disturbances.
IP2
IP2
SF
SF
TEMPORARY AND PERMANENT STABILIZATION SPECIFICATIONS
Temporary Seeding Permanent Seeding - Lawn Areas
Species: Annual Ryegrass Species: Kentucky 31
% Pure Live Speed: 98% Creeping Red Fescue
Application Rate: 25 LB/Acre Kentucky Bluegrass Mix
Fertilizer Type: 10-10-10 White Dutch Clover
Fertilizer Application Rate: 500 LB/Acre % Pure Live Speed: 98%, 98% 98%
Limiting Rate: 1 T./Acre Application Rate: 45-20-25-5 LB./Acre
Mulch Type: Hay Fertilizer Type: 10-20-10
Mulching Rate: 3 T./Acre Fertilizer Application Rate: 1000 LB/Acre
Liming Rate: Approx. 2 T./Acre OR To Achieve 6.5 pH Mulch Type: Clean Wheat or Oat Straw
Mulching Rate: 2 T./Acre
Anchor Material: None
Anchoring Method: None
Rate of Anchor Material Application: None
Seeding Season Dates: April 1 to May 30 or
Sept. 1 to Oct. 1
SOIL NAME AND
MAP SYMBOL
SOIL LIMITATIONS
ROADS
AND
STREETS
SHALLOW
EXCAVATIONS
LAWNS
AND
LANDSCAPING
COMMERCIAL
BUILDINGS
RECOMMENDATIONS
UkC
Urban land-Berks complex, 0 to 15 percent slopes
SwA
SWANDPOND SILT LOAM
0 TO 3 PERCENT SLOPES
Ub
URBAN LAND
SOIL NOT
RATED
VERY LIMITED:
SHRINK-SELL;
LOW STRENGTH;
FROST ACTION
SOIL NOT
RATED
SOIL NOT
RATED
NOT LIMITED
VERY LIMITED:
SHRINK-SWELL
EXERCISE CAUTION WHENEXCAVATING AND
ENSURE THAT FOUNDATIONS ARE BELOW FROST
LINES. MAINTAIN E&S AT ALL TIMES; CONTRACTOR
IS TO NOTIFY ENGINEER OF LIMITATIONS ARE
DISCOVERED DURING CONSTRUCTION
SOIL NOT
RATED
VERY LIMITED: TOO CLAYEY; DEPTH
TO SATURATED ZONE; UNSTABLE
EXCAVATION WALLS
SOIL NOT
RATED
SOIL NOT
RATED
SOIL NOT
RATED
SOIL NOT
RATED
MAINTAIN E&S AT ALL TIMES; CONTRACTOR IS TO
NOTIFY ENGINEER OF LIMITATIONS ARE
DISCOVERED DURING CONSTRUCTION
SOURCE: WEB SOIL USDA / NRCS WEB SOIL SURVEY ONLINE: HTTP://WEBSOILSURVEY.SC.EGOV.USDA.GOV
MAINTAIN E&S AT ALL TIMES; CONTRACTOR IS TO
NOTIFY ENGINEER OF LIMITATIONS ARE
DISCOVERED DURING CONSTRUCTION
BID DOCUMENTS
ee in ch es on e f oo t
6"
Department of
Veterans Affairs on e a nd on e h alf in ch es on e f oo t
6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.